Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2744 CARLSBAD BLVD; 102; AS070074
8/9/24,12:30 PM AS070074 Permit Data City of Carlsbad Sprinkler Permit o2 Job Address: 2744 CARLSBAD BL Permit Type: SPRINK Parcel No: 2031722701 Lot #: 0 Reference No.: Permit No: AS070074 Status: ISSUED Applied 3/22/2007 Approved: 3/27/2007 Issued: 3/27/2007 PC #: Inspector: Project Title: MERMAID BY THE SEA SUITE 102 TI FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: Owner: SCHMIDT FIRE PROTECTION CO INC SIMONS JOHN&MAUREEN 4760 MURPHY CANYON RD 2744 CARLSBAD BLVD #209 SAN DIEGO, CA 92123 CARLSBAD CA 858-279-6122 Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 about:blank 1/1 quick response) for prompt, precise operation. This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. 4J taUIiC® - 7AUTOMATIC SPRINRLERS OTECTION1"ñODUCTS V38, K5.6 Models V3801 and V3802 Adjustable Concealed Standard Spray Pendent Standard and Quick Response - —I PRODUCT DESCRIPTION This concealed, designer style sprinkler allows up to ½" (13 mm) adjustment to accommodate conceal- - ment needs. The "stan- dard" design provides a consistent hemispherical spray pattern. The sepa- ® V3801 rate two-piece mounting /3802 cup/cover plate allows easy See Victaulic installation and testing publication 10.01 prior to ceiling installation. for details. It also permits removal of suspended ceiling panels without system shutdown. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or - TECHNICAL SPECIFICATIONS Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard Nominal Orifice Size: ½" (13 mm) K-Factor: 5.6 Imp. (8,1 SLA) Nominal Thread Size: ½ NPT(l5mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Deflector: Bronze per UNS C22000 Cover Plate: Fusible solder Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: J Standard: 5,0 mm LI Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Stainless steel per UNS S30100 Seal: Teflon* tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene ACCESSORIES Installation Wrench: U Concealed: V38-4 or V38-5 Sprinkler Finishes: U Plain brass (only) Cover Finishes: LI Chrome plated U White painted U Flat black 13 Custom painted A For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. "Teflon is a registered trademark of Du-pont Co. - VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaufic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-742-5842) Phone: 905-884-7444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8817 Fax: 905-884-9174 Fax: 32-9-380-4438 Fax; 610-559-3608 Fax; 65-6235-0535 e-matl:ptckvic@victaultc.com e-mail: viccaoada@vicIaulic.com e-mail: viceuro@viclaalic.be e-mail: vical@viclaslic.com e-mail: vicap@victaulic.com 2558 Rev.E 5/04 1 5 Registered Trademark of Victaulic © Copyright 2004 Victaulic Printed in U.S.A. APPROVALS/LISTINGS Nominal Approvals $ K-Factor I Orifice Size imperial Deflector Model Inches/mm S.LA Response Type l.JL I FM I ULC NYC/MEAt I CSFM § V3801 I/ 5.6 Standard Concealed Pendent 155-200 I No 1135-200 135-200 1135-200 13 8,1 5 m bulb 68-93 I i 57-93 V3802 ½ 5.6 Quick Concealed Pendent 135-200 155-200@ 1135-2001 135-200 135-200 13 8,1 3 m bulb 57-93 -93 I I I 57-93 Listings and approval as of printing. For K-Factor when pressure is measured in Bar, multiply S. I. units by 10.0. @ Recognized by FM as standard response only. t MEA #62-99-E. § CSFM 417690-0531:112 RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in table below. SPRINKLER - V3801, V3802 COVER - V38 Sprinkler Temperature - °F/c Cover Temperature - Sprinkler Victaulic Glass Victaulic Nominal Maximum Nominal Maximum Temperature Part Temperature Ambient Temp. Bulb Part Temperature Ambient Temp. Classification IdentifIcation Rating Allowed Color Identification Rating Allowed Ordinary A 135 57 100 38 Orange A° 135 57 100 38 Ordinary C 155 68 100 38 Red Intermediate E 175 150 65 Yellow D4 165 74 150 65 Intermediate F 200 93 150 65 Green A ror use with Standard or Quick Response Concealed sprinster 135°F (57°C) or 155°F(68°C). D For use with Standard or Quick Response Concealed Sprinkler 175°F (79°C) or 200°F (93°C). Custom Finish - Customer to provide paint specification, allow 4 - 6 weeks for samples. Custom Covers require $150.00 minimum per custom cover; minimum 200 pieces. Proper temperature rated cover must be used with the correct sprinkler rating per the Temperature Chart Ratings. The plastic shipping cap must be removed for the sprinkler to operate properly. If shipping cap is replaced over an installed sprinkler for purposes of painting or plastering, then the tire protection system shall he considered out of service, the Authority Having Jurisdiction notified, and a tirewatch is suggested. Failure to do so may result In failure of sprinkler to operate causing serious personal injury or property damage. ORDERING INFORMATION Please specify the following when ordering: U Sprinkler Model Number U K-Factor U Cover Finish U Style U Thread Size U Wrench Model Number U Temperature Rating U Quantity Always read and understand Installation, care, and maintenance Instructions, supplied with each box of sprinklers, before proceeding with Installation 01 any sprinklers. Always wear safety glasses and foot protection. - • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 • installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) Is not allowed. Failure to follow these instructions could result In serious personal injury and/or property damage. The owner Is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. It you need additional copies of this publication, or It you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.50 -2 DIMENSIONS 2/16 (68 mm) Max. Hole Min. Hole 2/16 (59 mm) 11/2 (38 mm) Typical Ceiling Tile MINIMUM EXTENSION Finished Surface 3/16 (80 mm) 21 /1e (71 mm) 2"(51 mm) ½" (13 mm) Adjustment • Typical Ceiling Tile 31/4 (83 mm) Cover Plate Finished Surface MAXIMUM EXTENSION Models V3801, V3802 (Drawings not to scale) - AVAILABLE WRENCHES Recessed Concealed Pendent - V3801, V3802 V38-4 or V38-5 40.50 -3 - --- DISTRIBUTION PATTERNS MODELS V3801, V3802 K5.6 STANDARD CONCEALED PENDENT DISTRIBUTION PATTERNS -TRAJECTORY 10,.. 3,0 nt 8' 2,4 m 7psi 48 kPa 6' 1,8m 15 psi 103 kPa 4' 1,2 m 30 psi 207 kPa 2' 0,6 m 0 2' 4 6' 8' 10' 12' 14' 0,8m I,2m 1,8m 2,4m 3,0m 3,7m 4,3m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. - -- - WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shalt be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Viclaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.50 -4