HomeMy WebLinkAbout3001 CARLSBAD BLVD; ; FS0900158/9/24,12:46 PM FS090015 Permit Data City of Carlsbad Fixed Systems Permit Job Address: 3001 CARLSBAD BL Permit Type: FIXSYS Parcel No: 2032520600 Lot#: 0 Reference No.: Permit No: FS090015 Status: ISSUED Applied 4/1/2009 Approved: 4/1/2009 Issued: 4/1/2009 PC #: Inspector: Project Title: DAILY NEWS CAFE HOOD & DUCT SYSTEM PLAN CHECK & INSPECTIONS Applicant: Owner: CARLSBAD INN L L C C/O GRAND PACIFIC RESORT SERV 5900 PASTEUR CT #200 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 City of Carlsbad 04-06-2009 Fire Department Permit Permit No: FS090015 Job Address: 3001 CARLSBAD BL CBAD Permit Type: FIXSYS Subtype: HOOD Status: ISSUED Parcel No: 2032520600 . Lot #: 0 Applied: 04/01/2009 Issued: 04/01/2009 Fire Dept Ref: FS090015 Building Permit#: N/A Entered By: BSW Location: Project Title: DAILY NEWS CAFE Description: HOOD & DUCT SYSTEM PLAN CHECK & INSPECTIONS Contractor: METRO FIRE Phone: 619-670-3500 2735 VIA ORANGE WY Fax: SPRING VALLEY, CA 91978 Total Fees: $130.00 Total Payments To Date: $0.00 Plan Check Fee Additional Plan Check Fee Permit Fee Additional Permit Fee Re-Inspection Fee Other Additional Fees TOTAL PERMIT FEES $65.00 $0.00 $65.00 $0.00 $0.00 $0.00 $0.00 $130.00 NOTICE: Please take NOTICE that approval of your project includes the imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT O1dJ\)Ai. Plans for UL300 Upgrade of Kitchen Fire Suppression System Type: Ansul, R-102, 6 Gallon (2-3Gal. Tanks) , U.L.300 Approved, Wet Chem. System Location: Daily News Café 3001-A Carlsbad Blvd. Carlsbad, CA. 92008 760-729-1023 Submitted By: Metro Fire & Safety 2735 Via Orange Wy. #102 Spring Valley, CA. 91978 619-670-3500 619-670-5 100 (Fax) n C-16 Contr. Lic. # 909203 Contact: Gerry Reba @ 760-612-2526 Contents: Title Page General Notes Installation Diagram Room Overview Mfg's. Specs re: Required Nozzles, Nozzle heights, Flow Points, Max. Coverage Areas, Agent Cylinders and Flow Point Capacities. (Attached to ORIGINAL only INSPECTIONS AN TESTS flRE DEPT. 46 HOURS IN ADVANCE PHONE (760) 6024660 CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, ccndtions in correspondence and conformance with applicable regulations. The stamping of th ly_ese lans shall not be held to permit or violation of any __ GENERAL, NOTES: (Some notes may not be applicable depending on manufacturer of system installed) All installations procedures are in compliance with all manufacturer's specifications as outlined in NFPA 17A (2002), NIFPA 96(2008), California Fire Codes (CFC 2007) and UL300 Requirements. Remote pull station is mounted no lower than 36" and no higher than 48" from finished floor surface and on way to egress. Pull station clearly states use on cover plate. Control Head also operates as a pull station and indicates system as being "set" or "discharged" All appliance nozzles to be installed between minimum distances from center point of specified cooking hazard as prescribed in most current manufacturer technical manual. All plenum nozzles shall be installed at the midpoint of the area they protect and no further than 3" up from base of duct. All duct nozzles shall be installed at the midpoint of the area they protect and no further than 3" up from base of duct. System shall be tied into and supervised by building fire alarm system and activate general alarm upon discharge (if applicable). Automatic fuel shutdown device(s) shall shut down all sources of fuel, power and heat to protected equipment as required. Provide 2A lOBC rated portable extinguisher near service counter area in an easily accessible location. Provide "K" class rated fire extinguisher near protected cooking equipment but on way to egress. System to be test-fired and witnessed by fire authorities upon completion and prior to system being put into service. Test to include operation of remote pull station, last fusible link on detection line and fuel shutoff device. It will be the sole responsibility of the restaurant owner to maintain and service the system as prescribed by local and state laws. All supply air within 10 feet of hood shall shut down upon activation of system (or as dictated by A.H.J.). All exhaust air shall remain operational. Upon activation of any cooking equipment fire extinguishing system, all sources of fuel and power to all equipment protected by the system shall be shut off. INSTALLATION DIAGRAM Daily News Café I Carlsbad DUCTS (2) 16"x 16" 2W 2W 3 Gal. 3 Gal. f f Tank Tank UI U1 IN I IN 4- --------------------------------------------------------------------------------------------- Auto.Gas Shut Off 230 IN IN IN 245 IF IF Irir I H I®®®I I H(9®® Fryer Griddle Griddle 6 Burner Range Stock Pot Oven w/DripPar) 36"x24" 60"x24" 24"x36" 18"X 18" (No Nozzle 14"x 18" , Required) (* Indicates max. protection area and LEGEND prescribed nozzle mounting heights over appliances.) f 2W Nozzle, DUCT, *75" Perimeter max., 2 Flow Pts. x 2 = 4 Fl. Pts. + 1N Nozzle, PLENUM, *8 Ft. m, 1 Flow Pt.x3+3 Fl. Pts. 230 Nozzle, FRyER,*24"48" above app!., 2 Flow Pts. IN Nozzle, SM. GRIDDLE. *36" max., 35"-40" above app!.. 1 Flow Pt. x 33 Fl. Pts. 245 Nozzle, 4 Burn. RANGE, *40"-50" above appi, 2 Flow Pts. IF Nozzle, 2 Burn. RANGE, *30"..40" above app!., 1 Flow Pt. x 2= 2 FL Pts. rn 450 Deg. Heat Detection (Link Bracket) Indicates Plenum TOTAL OF 16 FLOW POINTS NOTE: Drawings NOT to scale. All pipe and fittings to be 3/8", Sch.40, Black pipe. Each Ansul 3 Gal. tank will support 11 flow points MAX. This is a TWO tank system. See attached Mfg's. Specs for verification. (Original Only). Pull Station to be located @ nearest egress. ROOM OVERVIEW Daily News Café / Carlsbad Pull Station "K" Elthl2. Auto.Gas Shut Off ;1~ 0 0 System Control and Tanks (2) SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-34 7-1-98 IREV.4 TANK AND CARTRIDGE REQUIREMENTS Once the hazard analysis is completed and the total nozzle, flow numbers are established, the quantity and size of agent tanks and cartridges needed to supply the nozzles with the proper volumes of agent at the proper flow rates can be determined. For cartridges used in the regulated release mechanism, flow capacities, tank quantities and sizes, and regulated release cartridge options are given in the table below. Total Quantity and Regulated Release Flow Size of Cartridge Options Numbers* Tank(s) Nitrogen Carbon Dioxide 1 - 5 (1) 1.5 Gallon LT-20-R (7032) 101-10 (15850) 6-11 (1) 3.0 Gallon LT-30-R (5373) 101-20 (17492) ii —16 (1) 1.5 Gallon Double (73022) 101-30 (15851). (1) 3.0 Gallon 16-22 (2) 3.0 Gallon Double (73022) 101-30 (15851)" When one or more regulated actuators are used, the following tank and cartridge combinations apply for each regulated actuator: Regulated Actuator Regulated Actuator Tank(s) Cartridge (1) 1.5 Gallon LT-20-R or 101-10 (1) 3.0 Gallon LT-30-R or 101-20 (1) 1.5 Gallon and LT-A-101-30 or 101-30" 3.0 Gallon 3.0 Gallon LT-A-101-30 or 101,.30** For exceptions to maximum flow numbers, see Distribution Piping Requirements for 1.5 gal- Ion and 3.0 gallon Systems in this Section. The 101-30 cartridge Part No,'15851. can not be used when (2) two 3.0 gallon tanks are man- itotdeci together.) For higher total flow numbers (23 to 110), multiple cartridges and regulated actuators are required as shown in the System Selection Guide in Section IX -Appendix. ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS --- This section contains the guidelines for installing the actuation a, expellant gas lines between the regulated release mechanism reg- ulator, each regulated actuator regulator, and each agent tank. These limitations should be considered when selecting the com- ponent mounting locations. Actuation Gas Line —6 to 8* Tanks Maximum 1.* 8 Tank maximum reflects the utilization of 3 tank regulated actuators. Use only 114 in. Schedule 40 black iron, hot-dipped galva- nized, chrome-plated, or stainless steel pipe and fittings. The actuation gas line piping is installed from the regulated release mechanism to each regulated actuator connected within the system. The total length of the actuation gas line from the regulated release assembly to the regulated actuator assembly(ies) must not exceed 20 ft. (6 m) when using an LT-20-R (Part No. 7032), an LT-30-R nitrogen cartridge (Part No. 5373), or a 101-10 (Part No. 15850) or a 101-20 (Part No. 17492) carbon dioxide cartridge. See Figure 73. REGULATED ACTUATOR ASSEMBLY EXPELLANT GAS LINES NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS REGULATED ACTUATOR ACTUATION GAS LINE WITH AN LT-20-R. LT-30-R. 101-to OR 101-20 CARTRIDGE MAXIMUM LENGTH OF 20 FT. (6 m). MAXIMUM NO. OF FITTINGS 9 REGULATED ACTUATOR ASSEMBLY,.. ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY FIGURE -7.1 SECTION IV - SYSTEM DESIGN UL E)(. 3470. uLc CEx747 Page 4-2 7-1-98 REV. 1 NOZZLE PLACEMENT REQUIREMENTS (Continued) Duct Protection (Continued) NOTICE A 2WH nozzle must be substituted for a 2W nozzle for any installation using Option 2 of the 1.5 gallon system coverage (6 flow duct and plenum protection only). 2.2W Nozzle (Part No. 419337): The R-102 System, uses the 2W nozzle (Part No. 419337) for duct protection of 75 in. (190.5 cm) perimeter or less, or 24 in. (61 cm) diameter or less. The nozzle tip is stamped with 2W, indicating that this is a two-flow nozzle and must be counted as two flow numbers. The 1W and 2W nozzles will protect the following: 3. Single Nozzle (2W) Duct Protection: One 2W nozzle will protect ducts with a maximum perimeter of 75 in. (190.5 cm) or a maximum diameter of 24 in. (61 cm). The nozzle must be installed 2-8 in. (5-20 cm) into the center of the duct opening and positioned as shown in Figure 4. 2 - 8 IN. (5 - 20 cm) FIGURE 4 000173 DUCT MODULE PERIMETER NOT MORE THAN 24 IN. (61 cm( TRANSITION FIGURE 6 '75 5. Dual-Nozzle Duct Protection: Two 2W nozzles will protect ducts with a maximum perimeter of 150 in. (381 cm) or a maximum diameter of 48 in. (122 cm). The nozzles must be installed 2-8 in. (5-20 cm) into the duct openingand positioned as in Figure 7. CT LENGTH FIGURE 7 175 4. Single Nozzle (2W) Transition Protection: One 2W nozzle will protect transitions at the point where the perimeter of 75. in. (190.5 cm) or the diameter of 24 in. (61 cm) or less begins within that transition. The nozzle must be placed in the Center of the transition opening where the maximum perimeter or diameter begins as shown in Figures 5 and 6. MODIJI NOT M 75. IN. NOTICE In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maximum, to a point just beyond the damper assembly that will not interfere with the damper. Exceeding the maximum of 8 in. (20 cm) in this way will not void the UL listing of the system. FIGURE 5 000174 000202 FIGURE 27a 20 IN. (51 cm) MAXIMUM 2 -4 1N. (5-10cm) 5.4 cm) M SECTION IV - SYSTEM DESIGN UL EX. 3470 ULCCEx747 Page 4-8 7-1-98 REV. 3 NOZZLE PLACEMENT REQUIREMENTS (Continued) Plenum Protection (Continued) 12 IN. (30 cm) MAXIMUM ¶7 8 IN. (20 cm) MAXIMUM NOZZLE TIP - MUST BE WITHIN THIS AREA FIGURE 26 '1N NOZZLE - PART NO. 419335 — SINGLE BANK PROTEC- TION One 1 nozzle will protect 8 linear feet (2.4 m) of single filter bank i plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The filter height must not exceed 20 in. (51 cm). See Figure 27a. 12-4 IN. (5—l0CM) 8 Fr. (2.4m) MAXIMUM / 1 N NOZZLE -PART NO. 419335— BANK PROTECTION Two IN nozzles will protect 8 linear feet (2.4 m) of "V" bank ,---" plenum. The nozzles must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The filter height o. must not exceed 20 in. (51 cm). See Figure 27b. 11- 2 FIGURE 27b Exception: When the plenum chamber contains filters that do not exceed 10 in. (25.4 cm) in height and the iN nozzle can be installed at the intersecting center lines of both filter banks and not exceed the 2-4 in. (5 to 10 cm) distance from either filters, a sin- gle 1 nozzle can be used. See Fure 27c. 4 IN. (10 c FIGURE 27c 000200 NOTICE If 1 N nozzle coverage does not exceed 7 linear ft. (2.1 m), the nozzle can be mounted 2 to 6 in. (5-15 cm) from the face of the filter. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-10 7-1-98 REV.4 NOZZLE PLACEMENT REQUIREMENTS (Continued) Fryer - Single Nozzle Protection (Continued) Maximum Area Dimensions - Single Nozzle Fryer Protection Max. Size Max. Size • Overall Type of Frypot Only With Dripboard Nozzle Full or Split Vat Full or Split Vat 230 / l4 in. xl5in. 14 in. x2lin. (36cmx38cm) (36cmx53cm) Full or Split Vat Full or Split Vat 245 l4 in. xl5in. l4 in. x2lin. (36 cm x 38 cm) (36 cm x 38 cm) 1 I i I I I II I I i I I I I I I I II I TOP OFFRYER i I 4- A FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 31 002280 Nozzle Height Nozzle Above Top of Fryer Location 27 in. to 47 in. See Figure (69 cm to 119 cm) 31 and 32 20 in. to 27 in. See Figure (51 cm to 69 cm) 31 and 32 1J FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD SPLIT VAT NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 32 - / TOP OF FRYER ZZLE PLACEMENT REQUIREMENTS (Contin u e d ) ddie Protection 1-Flow Nozzle The R-102 system uses four different noz z l e s f o r T h e p r o t e c t i o n o f griddles. One of the applications requi r e s a 1 - f l o w n o z z l e a n d three of the applications require a 2-flow n o z z l e . - High Proximity Application: 35 in. to 40 i n . ( 8 9 t o 1 0 2 c m ) above the cooking surface. This high proximity application uses t h e 1 N n o z z l e , P a r t N o . 419335. The nozzle tip is stamped with 1 N indic a t i n g t h i s i s a o n e - f l o w n o z - zle and must be counted as one flow num b e r . One 1 N nozzle will protect a maximum c o o k i n g a r e a o f 1 0 8 0 s q . in. (6968 sq. cm) with the maximum longest side of 36 in. ( 9 1 c m ) . When using this nozzle for griddle protec t i o n , t h e n o z z l e m u s t b e positioned along the cooking surface perim e t e r t o .a maximum of 2 in. (5 cm) inside the perimeter, and aim e d t o t h e m i d p o i n t o f t h e cooking surface. See Figure 50 and 51. NOTICE When using this type of griddle protectio n , o n l y 5 flow numbers are allowed on a 1.5 ga l l o n s y s - tem and only 11 flow numbers are allowed o n a 3 gallon system. I NOZZLE LOCATION 0-21N.)0--5crn) I INSIDE PERIMETER 40 IN. OF COOKING SURFACE II ft02cm) I / I MAXIMUM I HEIGHT II /)__ OF IN I II NOZZLE TIP 1 35 IN. )89cm) MINIMUM HEIGHT I EDGE II OF IN I OF -4 I NOZZLE TIP I COOKING I I SURFACE FIGURE 51 000243 fl MIDPOINT OF COOKING SURFACE h L I NOZZLE LOCATED ALONG ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN:(0—Scm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MID- POINT OF COOKING SURFACE. COOKING SURFACE EDGE FIGURE 50 OOO2l ) P. 245 NOZZLE TIP LOCATION CENTER 0 COOKING SURFACE OR 11 318 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NOZ TO CENTER OF ANY BURNER ING P. 245 NOZZLE TIP 7 LOCATION CENTER 0 COOKING SURFACE OR 11 3/8 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NO1 TO CENTER OF ANY BURNER ING FIGURE 45 SECTION IV SYSTEM DESIGN ' UL EX. 3470 ULC CEx747 Page 4-16 7-1-98 REV.4 NOZZLE PLACEMENT REQUIREMENTS (Continued) Range Protection 2-Flow Nozzle High Proximity Application (2-Flow Nozzle): 40 in: to 50 in. (102 cm to 127 cm) above the cooking surface. The high proximity application uses the 245 nozzle, Part No. 419340. The nozzle tip is stamped with 245 indicating this is a two-flow nozzle and must be counted as two flow numbers. r One 245 nozzle will protect a maximum cooking area of 672 sq. in. L (4335 sq. cm) with a maximum longest dimension of 28 in. (71 cm). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 44 and 45. 245 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE 7IN. I 1' (127 cm) MAXIMUM HEIGHT OF 245 NOZZLE TIP 40 IN. (102 cm) MINIMUM HEIGHT OF 245 NOZZLE TIP I-' 0000 —4 4 FIGURE 44 NOTICE Four burners shown in Figure 45. For single or double burners, locate nozzle at center of cook- ing surface or 11 3/8 in. (29 cm) maximum from nozzle centerline to center of any burner. .#IIUI'4 IV - DJICm jIIJiI UL EX. 3470 ULC CEx747 Page 4-15 7-1-98 REV. 3 1ZZLE PLACEMENT REQUIREMENTS (Continued) Range Protection 1-Flow Nozzle The R-1 02 system uses four different nozzles for the protection of ranges. One of the design options requires a one-flow nozzle and three of the design options require two-flow nozzles. NOTICE A 13 in. (33 cm) diameter wok pan is the largest wok size that can be protected on ranges. Range Protection (1-flow Nozzle) Single and multiple burner ranges can be protected using a 1 nozzle, Part No. 419333. The nozzle tip is stamped with 1 F, indi- cating that this is a one-flow nozzle and must be counted as one flow number. When using this nozzle for range protection, the maximum length of the burners being protected with a single nozzle must not exceed 28 in. (71 cm) and the maximum area of the burners must not exceed 336 sq. in. (2168 sq. cm) per nozzle. When protecting a two burner area, the 1 nozzle tip must be located anywhere on the burner centerline of the burners up to a maximum of 9 3/4 in. (24.8 cm) of horizontal distance from the nozzle tip to the center of either burner and shall be aimed to the center of the cooking surface. r The nozzle tip must be positioned so that the front-to-rear burner centerline and the tip flats are parallel. See Figure 42. When protecting a single burner, the nozzle must be located over either of the shortest edges. NOTE: Multiple 1 F nozzles can be used or can be combined with .propriate 2-flow nozzle protection to protect larger ranges. FRONT-TO-REAR CENTERLINE 93/4 IN. (24.8 cm) MAXIMUM i RIGHT-TO-LEFT CENTERLINE 7-9 IN. (18-23 cm) 28 IN. (71 cm) (18-23 CM) /• N T MAXIMUM 7 - 9 IN. NOZZLE TIP MUST BE POSITIONED SO THAT THE NOZZLE IS AIMED AT THE FRONT-TO-REAR CENTERLINE. AND THE NOZZLE TIP FLATS ARE PARALLEL WITH THE FRONT-TO-REAR CENTERLINE. 50 It. \j (127 cm) I) 30 IN. (76 cm) TIP FLATS 50 IN. (12 CM 30 IN. THIS HORIZONTAL DISTANCE CANNOT EXCEED 93/4 IN. 24.8 cm) 000771 FIGURE 42 When this type of hazard is equipped with a back shelf locat- ed above the range top, the 1 nozzle can also be utilized. See Figure 43 for nozzle location details. IF NOZZLE SHELF CAN OVERHANG BURNER(S) BY A MAXIMUM OF 11 IN. (28 cm) 12 IN. (30.5 cm) - IF NOZZLE TIP LOCATED ANYWHERE ON THE RIGHT-TO-LEFT CENTERLINE AND NOT MORE THAN 9 3/4 IN. (24.8 cm) HORIZONTAL DISTANCE FROM NOZZLE TIP TO CENTER OF BURNER. THE NOZZLE MUST BE LOCATED ALONG THE BURNER CENTERLINE. THE BURNER CENTERLINE MUST BE BETWEEN 7 -9 IN. (18-23 cm) FROM THE CENTER OF THE BURNERS BEING PROTECTED AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. 12 IN. (30.5 cm) MAXIMUM FRONT TO REAR CENTERLINE 14 IN. (35.6 cm) MAXIMUM 14 IN. (35.6 CM) 000238 MAXIMUM IF NOZZLE LOCATED OVER FRONT EDGE OF BURNER AND ORIENTED SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER FRONT TO REAR CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. FIGURE 43