Loading...
HomeMy WebLinkAbout300 CARLSBAD VILLAGE DR; 124; AS0501058/9/24, 2:17 PM AS050105 Permit Data City of Carlsbad Sprinkler Permit 300 CARLSBAD I2-4 Job Address: VILLAGE DR Permit Type: SPRINK Parcel No: 2031730500 Lot #: 0 Reference No.: Permit No: AS050105 Status: ISSUED Applied 5/17/2005 Approved: 5/20/2005 Issued: 5/20/2005 PC #: Inspector: Project Title: SKINSATIONAL FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: COSCO FIRE PROTECTION OREXCIV L L C STEIO5 10695 TREENA ST 12411 VENTURA BLVD SAN DIEGO, CA STUDIO CITY CA 858-444-2000 Fees ($) Add'I Fees ($) Total ($) Balance ($) 115 0 115 0 about:blank 1/1 FIRE PROTECTION San Diego Branch Office 10695 Treena Street., Suite #105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 Stale License No: C-16-5 77621 www.coscofire.com MATERIAL SUBMITTAL Date: May 5, 2005 TO: Carlsbad Fire Dept. SKINSATIONAL 300 CARLSBAD VILLAGE DR. #124 CARLSBAD, CA JOB# CD-3368 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: Justin Shelton Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle NFPA MUBER 0304 FIRE PROTECTION San Diego Branch Office 10695 Treena Street., Suite #105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 State License No: C-16-577621 www. coscofi re. corn TABLE OF CONTENTS 1. HEADS Imlabii Bulletin 136 Rev.L co Model Fl FR Model F1 FR Recessed Quick Response Sprinklers Model Fl FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall — HSW 1 Deflector Model F1FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters' Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council (LPC, UK) NYC BSM No. 587-75-SA Meets MIL-S-901C and MIL-STD 167-1 Verband der Schadenversicherer (VdS, Germany) NYC MEA 258-93-E UL Listing Category Sprinklers. Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Upright Pendent Vertical Sidewall Conventional Product Description awl R The Models F1 FR and F1FR Recessed autorriatic sprinklers ute the dischargiing water. The 'I temperature • of the sprinkler is identified by the color of the glass bulb. Horizontal Sidewall HSW 1 Deflector Recessed Pendent Application -. . Wick response sprinklers are used in fixed fire proteó-tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating. defiector. . style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the appring Authority Having Jurisdiction.- Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., inc. 525 North MacQuesten Parkwa% Mcxii Vernon. New Yok 10552 Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Mode D Sprinrier Virencti Installation Data: Sprinkler Type - K Factor I Sprinkler Identification Standard-Upright (SSU) and Pendent (SSP) Sprinkler Approval Detectors Marked to Indicate Position US Metric Height Organization Number (SIN) ssU Ssp )" (15mm) Standard Orifice wth )" NPT (R,1) Thread 5.6 80 2.2" (56mm) 12,3,45,6,7 R3625 P3615 (20wn) Large Orifice with %" NPT (R3/4)Thread 8.0 115 2.3" (58mm) 1,2,3,4,7,8 R3622 R3612 17mm)SmeiI Orifice with )" NPT (RX)Thread 4.2 60 2.54"(65mm) 1,2,8 P3623 R3613 %"_(1i)SmaJI Orifice with )ç'NPT(ft1)1Thwead 2.8 40 2.54" (65m11) 12,8 P3621 P3611 i(wi Orifice XLH with R% Thread 4.2 60 56. lrrm 4,6.7 P3624 P3614 Conventional-Install in Uptight or Pendent Position 4.2 5.6 8.0 60 80 115 56.lrrrn 56.1mm 58.4mm - 4.6.7 4,7 P3674 P3675 R3672 10nTn Orifice )QJ-4 wiuil W, Dwead 15mmStandard Orifice with)" NPT (PJ)Uread 2 Large Orifice 4PT(R14)Thread Upright Pendent Upright Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organization. Sprinkler identification Number (SIN) us Metric )"_(15mm) )NPT(RY) 5.6 80 22"(56mm) 1.2.3,4,5.7.8 P3615 %_(2Ckrrn) " NPT (R3A) 8.0 115 2.3" (58mm) 1,2,3 113612 (11mm) )"NPT(RV4 1 4.2 60 1 2.54"(65niTi) 1,2.8 P3613 %_(iQun) )"WT(R) 2.8 40 2.54"(65mi) 1,2.8 113611 4.2 60 56.lrnn 4,7 113614 "I Refer to escutcheon data table for aixovals and duTienslons. (ft•Z iiI. .l__, I St/V4 I ( r Am MUM (Mt soff ____ cr'nniPa 0_V y/ _ca*rIo IU Aww im (U W= .( s -_ 2. Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Heig ht Approval Organizations Sprinkler Identification Number (SIN) US Metric 'If '/1' NPT(RY2) 5.6 80 2.2" (56mm) 1, 2, 3, 6.8 15mm 142- NPT (RV2) 5.6 80 2.2 (56mm) 4 R3685 I LPC Approval is for Pendent position only. I Orientation I Deflector to CeIling Dimension (Mm. - Max.) I Upright 4- 12(102mm-305mm) I Pendent 6- 12"(152rTYn-305mm) I Vertical Sidewall 0 Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model 0 Sprinkler Wrench Installation Data: I K Factor I e 0 1za43ons 1çreva1 Sprinkler Identification I Nominal Orifice Thread Size I i US Metric I Sprinkler Length I Ught I Hazard Olnay1 Hazard Number I I (SIN) r2 ('&=) )NPT(R) 5.6 I 80 I 2.63'(67m) 1.2.3,5.8 j 1.2.5.8 ( R3635 NOTE: UL and ULC Usting permits use with Fl or F2 recessed escutcheon. Horizontal Sidewall 3. Finishes (1) ( Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated White Painted Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Oft White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult the factory for details. FM Approvals is limited to bronze and brass, chrome or black plated finishes only. FP Push-on/Thread-off escutcheon Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged .. ., separately. .• .. .. Installation O , -'> rosponse sprnklers are nen:eo for nsaaon as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model Fl FR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutch- eons illustrated are the only recessed escutcheons to be used with the Model F1FR Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Sprinkler Wrench. When installing Model F1FR Recessed Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Use the Model RC1 Wrench for installing F1FR Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. Temperature Ratings tjo s- Temperature Max. Ambient Temp. Bulb Color c4 Ordinary 57 135 1001F(38'C) Orange Ordinary 68 155 1OY'F(38C) Red Intermediate 79 I 175 150-F (65-C) Yellow Intermediate 93 I 203 150117 (66'C) Green High (1) 141 j 286 225'F(107C) Bk.e (1) Not available for recessed sprinklers. Escutcheon Data Escutcheon 'A FaC(AtIIn Model Ap3flWalS 4Ustit Dimension n b Cel igor Wall Dimension Fl 1Z4 (19mm) (19mm) (5rm-24-rrn) F2 12,3,4.5,7,8 47 1 X. (13nwn) (25mm) (5r - 17ni'n) F1' 1.2 FulyReoessed 34, (11 mm) 1.2 RAy Retracted VIr TlTead-df (24mm) Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen-tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini-mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Uprigni Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 The eqtipmerpreserted in this buSetin Is lobe Installed in accordance with die latest pertlient Standards o( the National Fire Protection Association. Factory Mutual Research Corporation, or other wAar 0r9n1zat10ns and also with the provisions Of governmental codes or ordinances whenever applicable. Products mariufactured and disuted by Reliable have been protecting lifeand property for over 80 years. and are installed and serviced by the most highly qualified and reputa-ble 5Qrider contractors located throughout the United Stales Canada and foreign coist'ies. Manufactured by Rellabld The Reliable AutomatIc Sprinkler Co. Inc. (831-1588 Sales Offices (800)848-6051 Sales Fax (914)668-3470 Corporate Offices Internet Address Revision Ines kidicalle updated or new data 80. F isd Am USA 3 PSe%e70027 - .-.-- - - .