Bulletin 014 Rev. J -
Model Fl FR Series
Quick Response
Standard Spray
w
CD
0
CD
C_
Model Fl FR56 Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall
Model F1FR56 Recessed Sprinkler Types
Standard Pendent/F1/F2/FP
Horizontal Sidewall
Model Fl FR56 Concealed Sprinkler Types
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler
Types
Standard Upright
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Recessed
Sprinkler Types
Standard Pendent
Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types*
Standard Pendent
Less than 0.25% Lead Content
Listing & Approvals
Underwriters Laboratories Inc. and Certified for
Canada (cULus).
Factory Mutual Approvals (FM)
Loss Prevention Council (LPCB, UK)
VdS SchadenverhUtung GmbH
Certified to NSF/ANSI Standard 61 Annex G
UL Listing Category
Sprinklers, Automatic & Open (VNlV)
Quick Response Sprinkler
Product Description
Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL,
Fl FRXLH & Fl FR28 Series Sprinklers are quick response
sprinklers which combine the durability of a standard sprin-
kler with the attractive low profile of a decorative sprinkler.
The Models Fl FR56, Fl FR56LL, Fl FR42, F1FR42LL,
Fl FRXLH & Fl FR28 Series Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers have
demonstrated response times in laboratory tests which are
five to ten times faster than standard response sprinklers.
This quick response enables the Model Fl FR56, Fl FR56LL,
F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers
Upright Pendent Conventional
Vertical Sidewall Horizontal Sidewall Recessed
PendentlFliF2
Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP
XLH Upright XLH Pendent
Pendent Fl/F2 to apply water to a fire much faster than
standard sprinklers of the same tem-
perature rating. ( '" The glass bulb consists of an accu-
rately controlled amount of special fluid
hermetically sealed inside a precisely
manufactured glass capsule. This glass
XLH Recessed bulb is specially constructed to provide Pendent FP fast thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid and vapor phases. The vapor phase can
be seen as a small bubble. As heat is applied, the liquid
expands, forcing the bubble smaller and smaller as the liq-
uid pressure increases. Continued heating forces the liquid
to push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distrib-
ute the discharging water.
TheReliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
FILE1 COPY AS13o td l
Application
Quick response sprinklers are used in fixed fire protection syste
m
s
:
W
e
t
,
D
r
y
,
D
e
l
u
g
e
o
r
P
r
e
a
c
t
i
o
n
.
C
a
r
e
m
u
s
t
b
e
exercised that the orifice size, temperature rating, deflector style and sp
r
i
n
k
l
e
r
t
y
p
e
a
r
e
i
n
a
c
c
o
r
d
a
n
c
e
w
i
t
h
t
h
e
l
a
t
e
s
t
published standards of the National Fire Protection Association or th
e
a
p
p
r
o
v
i
n
g
A
u
t
h
o
r
i
t
y
H
a
v
i
n
g
J
u
r
i
s
d
i
c
t
i
o
n
.
Q
u
i
c
k
response sprinklers are intended for installation as specified in NFPA 13.
Q
u
i
c
k
r
e
s
p
o
n
s
e
s
p
r
i
n
k
l
e
r
s
a
n
d
s
t
a
n
d
a
r
d
r
e
-
sponse sprinklers should not be intermixed.
PTh tie
Deflector
(XLH Only)
Load Screw Washer
Bulb
Frame Cup
O14FGO6A
Model F1FR42, F1FRXLH Uriqht
Technical data:
Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure
F1FR56
**F1 FR56LL01 K 5.6
Quick 1/2' NPT See See
F1FR42
**F1FR42LLCI) K 4.2 Response (R1/2) 175 PSI 7 PSI 'Temperature Finish Table" F1FRXLH
K_2.8
Ratings' Table.
F1FR28
(11 Low Lead Sprinklers available only with Temperature Rating 200°F/93°C
Material Data:
Frame Deflector Load Screw *pintle Cup Washer Bulb
DZR Brass CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 OM Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy 544 CDA Alloy 544 CDA Alloy5l0
CDA Alloy 693 Tape
2.
Model F1FR56, Upright, Pendent & Conventional Sprinklers
Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers
Installation Wrench: Model 0 Sprinkler Wrench
Installation Data:
Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number
Orifice
Size US Metric Height Organization Upright Pendent
Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position
1/2' (15mm)0' 1/2' NPT (R1/2) 5.6 80 2.25' (57mm) 1,2,3,4 RA 14250)(2)(3) RA14140"0>'2' 7/16"(10mm) 1/2" NPT (R1/2) 4.2
1
60 2.25" (57mm) 1 RA 1423") RA1413 3/8"(10mm) 1/2" NPT(IR1/2) 2.8 40 2.25" (57mm) 1 RA14210' RA1411 Conventional-Install in Upright or Pendent Position
15mm'" 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3,4 RA1475'3' cULus listed corrosion resistant (Polyester coated) sprinkler.
(2) Polyester coated FM approved sprinkler.
Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475.
Upright Pendent Conventional
Model F1FR56LL & F1FR42LL Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number
(SIN) Orifice
Size US Metric Height Organization Pendent
Standard-Pendent Deflectors Marked to Indicate Position
1/2" (15mm) " 1/2" NPT (R1/2) I 5.6 80 2.25" (57mm) 1 1,5 IRA1414
7/16(11mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1,5 RA1413 M cULus listed corrosion resistant (Polyester coated) sprinkler.
3.
Model F1FR56, F1FR42, FIFRXLH & F1FR28 Quick Response Recessed Pendent
S
p
r
i
n
k
l
e
r
"
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread -- K Factor
Size US
Sprinkler
Height
Sprinkler Identification Number
(SIN)
1/21(15mm) 1/2'_NPT(R½) 5.6
_Metric
_80 2.25"(57mm) RA1414
7/16'_(10mm) 1/2'_NPT(R1/2) 4.2 2.25"(57mm) RA 1413 3/8(10mm) 1/2"NPT(R1/2) 2.8
_60
_40 2.25" (57mm) RA1411 Refer to escutcheon data table for approvals & dimensions
Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent SprinkIer0 Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Thread I K Factor Sprinkler Sprinkler Identification Number Orifice Size US _Metric Height (SIN)
1/2"(15mm) 1/2"NPT(R½) i 5.6 _80 2.25"(57mm) RA 1414
7/16"(10mm) 1/2"NPT(R1/2) 4.2 _60 2.25"(57mm) RA 1413 (I) Refer to escutcheon data table for approvals & dimensions
' A 'CE AENGER IA
71 I J j Ar 4M4s$RIu RECeSS 723 4,.,.,,] I - Ar URAMAM RECESS -
—L FIZZ42
F'_EXL'lC.EOS ADMJSWRSl f Al MSK111 RECESS ','RT2JRA,.,,J
Al MIXIMUM RECESS _l,J2a Al MSM CESS - -3/ 4P
r
S Al, cc
'II SOUlS -
2 5/16' o1[MA,.,)
EAC.( Of OPALS To I-ACE or CEILING DLMCNS.ON
.11 MAOISt/N RECESS - )-,!2758mr,J 2 SWIM/AS RECESS '725s]
Al MAE/IRIS RECESS 8/I8E43v,,J
T SAL/MI/S ACCESS '7254r.sJ
.1 l/IALS
Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28F1 or F2 F1FR28FP
Model Fl FR56 Quick Response Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installation Data:
P Nominal Nominal K Factor { Sprinkler I Approval Sprinkler
US Metric I Orifice Thread Size
Height Identification Organizations Numbers (SIN) /2' (15mm) ½' NPT (R1/2) I 5.6 I 8.0 I 2.25" (57mm) I 1,2,3,4\i 15mm ½" NPT (131/2) 5.6 8.0 2.25" (57mm) RA1485 2
LPC Approval is for pendent position only.
° cULus Listed corrosion resistant (Polyester coated) sprinkler.
Vertical Sidewall
4.
Sprinkler Type Deflector to Ceiling Distancel
Mm.-Max.)
Upht
1:7-Pendent 4"05mm)J
4" 102mm - 052rnL4
Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler
Deflector: HSW
Installation Wrench: Model D Sprinkler Wrench
Installation Data: Horizontal Sidewall
Nominal Orifice Thread Size
Nominal K Factor
_________________
Sprinkler
Height
Approval Organizations
and Type of Approval Sprinkler
Identification
Light Hazard 1, Ordinary Numbers (SIN) Hazard
US Metric
'/2" ½" (15mm) ½' NPT (R1/2) 5.6 L_80 2.63" (67mm) L 1,2 1 RA1435()(2) cULus Listed corrosion resistant (Polyester coated) sprinkler.
( Polyester coated FM approved sprinkler.
FACE OF FIT/IWO
TO FACE OF CEILING DIMENSION
AT MIX/MUM RECESS I AT MINIMUM RECESS 3/8"[9.5m,]
F2 ESCU7C
AT MAX/MUM RECESS J14 [79-1] AT MINIMUM RECESS
-2 1/4" HOLE 0/4.
[57.2mm]
IX 1/2" REDUCER—
AT MAXIMUM RECESS 1-3/8734.9m'r.] AT MINSAWU RECESS 2-1/16752. 4mmJ
- E2E5QLEGMQLI
AT MAXIMUM RECESS
-1/R" AT MINIMUM RECESS = 2- I/;6T52.4mJ
[3.2mm]
- ______________-_l (i 4"-2"
[1076mm-.104.Rmm] 2 27/32 0/A. CEILING To [72.2,-1 DEFLECTOR
F1 ESCIALtTON
j 3/4 "[19mm] ADJUSTMENT
E5CUT'HEcI
7/27 '2. 7mm] ADJUSTMENT
Horizontal Sidewall i 15116 - CIA
TURN COLLAR UNTIL -,
TIGHT AGAINST SPRINKLER
WRENCH BOSS.
RECESSED HSW VEI QR--EL!-5-CUTQJHE0N (I) FM APPROVED FOR 4" - 6" [101.644M 152,01!4 CEILING 10 DEFLECTOR,
Note: For Recessed HSW Sprinklers use installation wrench GFR2.
Model Fl FR56 Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
Nominal "K" Factor Thread Temp. Rating Max. Bulb Sprinkler
Sprinkler Cover Orifice
______________.
us Metric Size Model Ambient
Temp Color Approvals Identification
Number(SIN)
1/2' (15mm) 5.6 80 1 1/2" NPT F1FR 135°F/57°C 135°F/57°C 1000F/381C Orange 1 RA 1414
1/2 ' (15mm) 5.6 80 ½" NPT F1FR 155°F/68°C 135°F/57°C 1001F/38°C Red 1,4/1/ RA 1414
½" (15mm) 5.6 80 1/2" NPT F1FR 175°F/791C 165°F/74°C 1001F/38°C Yellow 1 RA 1414
½" (15mm) 5.6 80 1 ½" NPT F1FR 2001F/931C I 165117/741C 150°F/65°C Green 1 RA1414 (I) For VdS only = 155°F/68°C Norbulb and 1/2" [12,7mm) adjustment.
Model Fl FR56LL Quick Response Concealed Pendent Sprinklers \ Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
III1IIIrNominal Factor ThreadJe1 Size Sprinkler Cover Identification......forOrifice
Max
Ambient Bulb Ambient
Temp .
Sprinkler
Number(SIN)
US Metric
½ (15mm) 56 80 /2 NPT F1FR56LL1 2001F/931C 165 Ff74 C 150 Ff65 C Green 1
, 5 RA 1414
5.
lx 112 REDUCING
TEE OIl ELBOW
- _rii1
...
---.4— 2 ./B 111A,25/16D!A._j -- HOLEINCEILING
CUP — .- - __
112 MAX
PACE OF FITTING
CEILING
TO FACE OF CEILING
-:
DIMENSION
/ ft COVER A
COVER PL4IE— ASSEMBLY
- 3 5/16 014 -. SPRINKL ER
Figure 1
Installation Aid
A protective cap is included for use during installation.
Important: The F1FR56 Sprinkler with Model CCP cover
plate is not an FM Approved combination.
Installation
Quick response sprinklers are intended for installation as
specified in NFPA 13. Quick response sprinklers and stan-
dard response sprinklers should not be intermixed.
The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH & F1FR28 Recessed Quick Response Sprin-
klers are to be installed as shown. The Model Fl or F2 Es-
cutcheons illustrated are the only recessed escutcheons
to be used with the Model F1FR56, F1FR56LL, F1FR42,
F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any
other recessed escutcheon will void all approvals and ne-
gate all warranties.
When installing Model F1FR56, F1FR56LL, F1FR42,
F1FR42LL, F1FRXLH & Fl FR28 Sprinklers, use the Model
D Sprinkler Wrench. Use the Model GFR2 Wrench for install-
ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH &
Fl FR28 Recessed Pendent Sprinklers. Any other type of
wrench may damage these sprinklers.
NOTE: A leak tight ½" NPT (R1/2) sprinkler joint can be
obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do
not tighten sprinklers over maximum recommended torque.
It may cause leakage or impairment of the sprinklers.
The Models F1FR56/CCP & F1FR56LL/CCP Concealed
Sprinkler use the ½" orifice, ½" NPT (R1/2), Model F1FR56
& Fl FR56LL Pendent Sprinkler with a threaded Model COP
cup which is factory attached to the sprinklers. The Model
F1FR56 Pndent is available in temperature rating of 135°F
(570C), 155°F (680C), 175°F (79°C) or 200°F (930C). The
Model F1FR56LL Pendent is available only in a rating of
200°F (930C). The concealed sprinkler assemblies are com-
pleted by the installation of the attractive low profile Model
CCP push on cover plate assembly, rated 135°F (57°C) or
165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FlFR56
LL. The cover plate and sprinkler cup assemblies are joined
using a cover plate skirt with flexible tabs for threaded en-
1' x 1/2" I1EOUC1NG TEE OR ELBOW
1 2 5/5 OH. 2 5,116 Do HOLE IN HG
-. FACE OF F11,1G I! Ill It'll EQ FACE OF CEILING
DIMENSION
CEILING
51116" MAX. J114 COVER ACJUSTMENT
ASSEMBLY 35/6 3A
SPRINKlER
CONCEALED, 5/16' ADJUSTMENT
Figure 2
gagement. A choice of two cover plate assemblies provide
either 1/2" (13mm) or 5/8" (8mm) of cover adjustment,
Do not install these sprinklers in ceiling which have positive
pressure in the space above.
After a 2 /8" (67mm) diameter hole is cut in the ceiling, the
sprinkler is easily installed with the Model RC1 Wrench. A
Teflon* based thread sealant should be applied to the sprin-
kler threads only The Model RC1 Wrench is then used to
engage the sprinkler wrenching surfaces and to install
the sprinkler in the fitting. When inserting or removing the
wrench from the sprinkler/cup assembly, care should be tak-
en to prevent damage to the sprinkler. DO NOT WRENCH
ON ANY OTHER PART OF THE SPRINKLER. The cover
plate is then pushed onto the cup. Final adjustment is made
by hand turning the cover plate until the skirt flange makes
full contact with the ceiling. Cover plate removal requires
turning in the counter clockwise direction.
After installation, inspect all sprinklers to ensure that there
is a gap between the cover plate and ceiling and that the
four cup slots are open and free from any air flow impedi-
ment to the space above.
Concealed cover plate/cup assemblies are listed only for
use with specific sprinklers. The use of any other concealed
cover plate/cup assembly with the Model Fl FR56 Pendent
Sprinkler or the use of the Model CCP Concealed cover
plate assembly on any sprinkler with which it is not specifi-
cally listed my prevent good fire protection and will void all
guarantees, warranties, listings and approvals.
Glass bulb sprinklers have orange bulb protectors to
minimize bulb damage during shipping, handling and in-
stallation. REMOVE THIS PROTECTION AT THE TIME THE
SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE
PROTECTION. Removal of the protectors before this time
may leave the bulb vulnerable to damage. RASCO wrench-
es are designed to install sprinklers when covers are in
place. REMOVE PROTECTORS BY UNDOING THE CLASP
BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO-
TECTORS.
*DuPont Registered Trade Mark
6.
Temperature Ratings
Classification Temperature Ambient
Temp. Bulb Color °C °F
Ordinary 57 135 100°F(38°C) Orange Ordinary 68 155 100°F(38°C) Red Intermediate 79 175 150°F(66°C) Yellow Intermediate 93 200 150°F (66°C) Green High (1) 141 286 225°F (107°C) Blue
' Not available for recessed sprinklers.
Escutcheon Data (1)
"SIN RA1435 - cULus permits use with Fl F2 or FP escutcheons for "light
hazard" only, while FM limits use for same hazard with F2 escutcheon only.
Maintenance
The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH and Model F1FR56 F1FR56LL, F1FR42,
Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should
be inspected quarterly and the sprinkler system maintained
in accordance with NFPA 25. Do not clean sprinklers with
soap and water, ammonia or any other cleaning fluids.
Remove dust by using a soft brush or gentle vacuuming.
Remove any sprinkler which has been painted (other than
factory applied) or damaged in any way. A stock of spare
sprinklers should be maintained to allow quick replacement
of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons and
packaging to minimize the potential for damage to sprinklers
that would cause improper operation or non-operation.
Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Recessed Pendent
Vertical Sidewall
Horizontal Sidewall
Recessed Horizontal sidewall
Concealed pendent
Maximum Working Pressure
175 psi (12 bar)
100% Factory tested hydrostatically to 500 psi (34.5 bar)
Finishes (1)
Standard Finishes
Sprinkler 7—
Cover plate(') Bronze Brass
Chrome Plated Chrome Chrome Polyester Plated White Coated 4)(5)(6) White Painted Special Application Finishes
Sprinkler Escutcheon Cover jat&" Bright Brass Bright Brass Bright Brass Black Plated Black Plated Satin Black Paint (2)(6 Black Paint Oft White Off White 12X6) Off White Black Paint SatinChrome Satin Chrome Black Plated
Other finishes and colors are available on special order. Consult the
factory for details. Custom color painted sprinklers may not retain their
UL Corrosion resistance listing. Coverplate custom paint is semi-gloss,
unless specified otherwise.
21 cULus Listed only.
200°F (93°C) maximum.
(11 cULus listed 'corrosion resistance" applies to SIN Numbers RA1435
(HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and
RA1415 (Pendent) in standard black or white. Corrosion resistance in
other polyester colors is available upon request.
° FM Approvals finish as 'Polyester coated' applies to SIN Number
RA1414, RA1435 and RA1425 in standard black or white.
6 LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475.
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Orifice Size
Deflector Type
Temperature Rating
Sprinkler Finish
Escutcheon Type
Escutcheon Finish (where applicable)
Cover plate Model
Cover plate Thread size
Cover plate Temperature
Cover plate Adjustment
Cover plate Finish
Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers
and escutcheons are packaged separately.