Loading...
HomeMy WebLinkAbout880 CARLSBAD VILLAGE DR; ; AS1301218/9/24, 2:21 PM AS130121 Permit Data City of Carlsbad Sprinkler Permit 880 CARLSBAD Job Address: VILLAGE DR Permit Type: SPRINK Parcel No: 2033541600 Permit No: AS130121 Status: APPROVED Applied 7/26/2013 Approved: 7/30/2013 Lot #: 0 Reference No.: Issued: 7/30/2013 PC #: Inspector: Project Title: CARECRAFT T.l. TI_5,387 SF AT 2ND FLOOR OF EXISTING 2 STORY, MIXED USE RETAIL & OFFICE BLDG Applicant: INNOVATIVE FIRE PROTECTION INC STE 101 8779 COTTONWOOD AV SANTEE CA (619) 593-8200 (619)593-9133 Owner: BURECK CAPITAL L L C 1923 DENTRO DE LOMAS BONSALL CA Fees ($) Adcrl Fees ($) Total ($) Balance ($) 268 0 268 0 about:blartk 1/1 Bulletin 014 Rev. J - Model Fl FR Series Quick Response Standard Spray w CD 0 CD C_ Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH Certified to NSF/ANSI Standard 61 Annex G UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, Fl FRXLH & Fl FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models Fl FR56, Fl FR56LL, Fl FR42, F1FR42LL, Fl FRXLH & Fl FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR56, Fl FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed PendentlFliF2 Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent Pendent Fl/F2 to apply water to a fire much faster than standard sprinklers of the same tem- perature rating. ( '" The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass XLH Recessed bulb is specially constructed to provide Pendent FP fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. TheReliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 FILE1 COPY AS13o td l Application Quick response sprinklers are used in fixed fire protection syste m s : W e t , D r y , D e l u g e o r P r e a c t i o n . C a r e m u s t b e exercised that the orifice size, temperature rating, deflector style and sp r i n k l e r t y p e a r e i n a c c o r d a n c e w i t h t h e l a t e s t published standards of the National Fire Protection Association or th e a p p r o v i n g A u t h o r i t y H a v i n g J u r i s d i c t i o n . Q u i c k response sprinklers are intended for installation as specified in NFPA 13. Q u i c k r e s p o n s e s p r i n k l e r s a n d s t a n d a r d r e - sponse sprinklers should not be intermixed. PTh tie Deflector (XLH Only) Load Screw Washer Bulb Frame Cup O14FGO6A Model F1FR42, F1FRXLH Uriqht Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL01 K 5.6 Quick 1/2' NPT See See F1FR42 **F1FR42LLCI) K 4.2 Response (R1/2) 175 PSI 7 PSI 'Temperature Finish Table" F1FRXLH K_2.8 Ratings' Table. F1FR28 (11 Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 OM Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy 544 CDA Alloy 544 CDA Alloy5l0 CDA Alloy 693 Tape 2. Model F1FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model 0 Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number Orifice Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2' (15mm)0' 1/2' NPT (R1/2) 5.6 80 2.25' (57mm) 1,2,3,4 RA 14250)(2)(3) RA14140"0>'2' 7/16"(10mm) 1/2" NPT (R1/2) 4.2 1 60 2.25" (57mm) 1 RA 1423") RA1413 3/8"(10mm) 1/2" NPT(IR1/2) 2.8 40 2.25" (57mm) 1 RA14210' RA1411 Conventional-Install in Upright or Pendent Position 15mm'" 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3,4 RA1475'3' cULus listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Upright Pendent Conventional Model F1FR56LL & F1FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Orifice Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) " 1/2" NPT (R1/2) I 5.6 80 2.25" (57mm) 1 1,5 IRA1414 7/16(11mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1,5 RA1413 M cULus listed corrosion resistant (Polyester coated) sprinkler. 3. Model F1FR56, F1FR42, FIFRXLH & F1FR28 Quick Response Recessed Pendent S p r i n k l e r " Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread -- K Factor Size US Sprinkler Height Sprinkler Identification Number (SIN) 1/21(15mm) 1/2'_NPT(R½) 5.6 _Metric _80 2.25"(57mm) RA1414 7/16'_(10mm) 1/2'_NPT(R1/2) 4.2 2.25"(57mm) RA 1413 3/8(10mm) 1/2"NPT(R1/2) 2.8 _60 _40 2.25" (57mm) RA1411 Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent SprinkIer0 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread I K Factor Sprinkler Sprinkler Identification Number Orifice Size US _Metric Height (SIN) 1/2"(15mm) 1/2"NPT(R½) i 5.6 _80 2.25"(57mm) RA 1414 7/16"(10mm) 1/2"NPT(R1/2) 4.2 _60 2.25"(57mm) RA 1413 (I) Refer to escutcheon data table for approvals & dimensions ' A 'CE AENGER IA 71 I J j Ar 4M4s$RIu RECeSS 723 4,.,.,,] I - Ar URAMAM RECESS - —L FIZZ42 F'_EXL'lC.EOS ADMJSWRSl f Al MSK111 RECESS ','RT2JRA,.,,J Al MIXIMUM RECESS _l,J2a Al MSM CESS - -3/ 4P r S Al, cc 'II SOUlS - 2 5/16' o1[MA,.,) EAC.( Of OPALS To I-ACE or CEILING DLMCNS.ON .11 MAOISt/N RECESS - )-,!2758mr,J 2 SWIM/AS RECESS '725s] Al MAE/IRIS RECESS 8/I8E43v,,J T SAL/MI/S ACCESS '7254r.sJ .1 l/IALS Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28F1 or F2 F1FR28FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: P Nominal Nominal K Factor { Sprinkler I Approval Sprinkler US Metric I Orifice Thread Size Height Identification Organizations Numbers (SIN) /2' (15mm) ½' NPT (R1/2) I 5.6 I 8.0 I 2.25" (57mm) I 1,2,3,4\i 15mm ½" NPT (131/2) 5.6 8.0 2.25" (57mm) RA1485 2 LPC Approval is for pendent position only. ° cULus Listed corrosion resistant (Polyester coated) sprinkler. Vertical Sidewall 4. Sprinkler Type Deflector to Ceiling Distancel Mm.-Max.) Upht 1:7-Pendent 4"05mm)J 4" 102mm - 052rnL4 Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal Orifice Thread Size Nominal K Factor _________________ Sprinkler Height Approval Organizations and Type of Approval Sprinkler Identification Light Hazard 1, Ordinary Numbers (SIN) Hazard US Metric '/2" ½" (15mm) ½' NPT (R1/2) 5.6 L_80 2.63" (67mm) L 1,2 1 RA1435()(2) cULus Listed corrosion resistant (Polyester coated) sprinkler. ( Polyester coated FM approved sprinkler. FACE OF FIT/IWO TO FACE OF CEILING DIMENSION AT MIX/MUM RECESS I AT MINIMUM RECESS 3/8"[9.5m,] F2 ESCU7C AT MAX/MUM RECESS J14 [79-1] AT MINIMUM RECESS -2 1/4" HOLE 0/4. [57.2mm] IX 1/2" REDUCER— AT MAXIMUM RECESS 1-3/8734.9m'r.] AT MINSAWU RECESS 2-1/16752. 4mmJ - E2E5QLEGMQLI AT MAXIMUM RECESS -1/R" AT MINIMUM RECESS = 2- I/;6T52.4mJ [3.2mm] - ______________-_l (i 4"-2" [1076mm-.104.Rmm] 2 27/32 0/A. CEILING To [72.2,-1 DEFLECTOR F1 ESCIALtTON j 3/4 "[19mm] ADJUSTMENT E5CUT'HEcI 7/27 '2. 7mm] ADJUSTMENT Horizontal Sidewall i 15116 - CIA TURN COLLAR UNTIL -, TIGHT AGAINST SPRINKLER WRENCH BOSS. RECESSED HSW VEI QR--EL!-5-CUTQJHE0N (I) FM APPROVED FOR 4" - 6" [101.644M 152,01!4 CEILING 10 DEFLECTOR, Note: For Recessed HSW Sprinklers use installation wrench GFR2. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal "K" Factor Thread Temp. Rating Max. Bulb Sprinkler Sprinkler Cover Orifice ______________. us Metric Size Model Ambient Temp Color Approvals Identification Number(SIN) 1/2' (15mm) 5.6 80 1 1/2" NPT F1FR 135°F/57°C 135°F/57°C 1000F/381C Orange 1 RA 1414 1/2 ' (15mm) 5.6 80 ½" NPT F1FR 155°F/68°C 135°F/57°C 1001F/38°C Red 1,4/1/ RA 1414 ½" (15mm) 5.6 80 1/2" NPT F1FR 175°F/791C 165°F/74°C 1001F/38°C Yellow 1 RA 1414 ½" (15mm) 5.6 80 1 ½" NPT F1FR 2001F/931C I 165117/741C 150°F/65°C Green 1 RA1414 (I) For VdS only = 155°F/68°C Norbulb and 1/2" [12,7mm) adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers \ Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: III1IIIrNominal Factor ThreadJe1 Size Sprinkler Cover Identification......forOrifice Max Ambient Bulb Ambient Temp . Sprinkler Number(SIN) US Metric ½ (15mm) 56 80 /2 NPT F1FR56LL1 2001F/931C 165 Ff74 C 150 Ff65 C Green 1 , 5 RA 1414 5. lx 112 REDUCING TEE OIl ELBOW - _rii1 ... ---.4— 2 ./B 111A,25/16D!A._j -- HOLEINCEILING CUP — .- - __ 112 MAX PACE OF FITTING CEILING TO FACE OF CEILING -: DIMENSION / ft COVER A COVER PL4IE— ASSEMBLY - 3 5/16 014 -. SPRINKL ER Figure 1 Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the ½" orifice, ½" NPT (R1/2), Model F1FR56 & Fl FR56LL Pendent Sprinkler with a threaded Model COP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (570C), 155°F (680C), 175°F (79°C) or 200°F (930C). The Model F1FR56LL Pendent is available only in a rating of 200°F (930C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model CCP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FlFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- 1' x 1/2" I1EOUC1NG TEE OR ELBOW 1 2 5/5 OH. 2 5,116 Do HOLE IN HG -. FACE OF F11,1G I! Ill It'll EQ FACE OF CEILING DIMENSION CEILING 51116" MAX. J114 COVER ACJUSTMENT ASSEMBLY 35/6 3A SPRINKlER CONCEALED, 5/16' ADJUSTMENT Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2 /8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model Fl FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. *DuPont Registered Trade Mark 6. Temperature Ratings Classification Temperature Ambient Temp. Bulb Color °C °F Ordinary 57 135 100°F(38°C) Orange Ordinary 68 155 100°F(38°C) Red Intermediate 79 175 150°F(66°C) Yellow Intermediate 93 200 150°F (66°C) Green High (1) 141 286 225°F (107°C) Blue ' Not available for recessed sprinklers. Escutcheon Data (1) "SIN RA1435 - cULus permits use with Fl F2 or FP escutcheons for "light hazard" only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56 F1FR56LL, F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler 7— Cover plate(') Bronze Brass Chrome Plated Chrome Chrome Polyester Plated White Coated 4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover jat&" Bright Brass Bright Brass Bright Brass Black Plated Black Plated Satin Black Paint (2)(6 Black Paint Oft White Off White 12X6) Off White Black Paint SatinChrome Satin Chrome Black Plated Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. 21 cULus Listed only. 200°F (93°C) maximum. (11 cULus listed 'corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. ° FM Approvals finish as 'Polyester coated' applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. 6 LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7.