HomeMy WebLinkAbout6480 EL CAMINO REAL; ; FA0600229/19/24, 11:36 AM FA060022 Permit Data City of Carlsbad Fire Alarm Permit 6480 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 2150202700 Lot #: 0 Reference No.: Permit No: FA060022 Status: ISSUED Applied 5/31/2006 Approved: 5/31/2006 Issued: 5/31/2006 PC #: Inspector: Project Title: CASSIA HEIGHTS APTS FIRE ALARM/MONITORING INSPECTIONS Applicant: EMCOM ELECTRONIC SYSTEMS, INC SUITE H 256 WITHERSPOON WY EL CAJON, CA 619-667-1200 Owner: CITY OF CARLSBAD CALIFORNIA STATE ASSESSED Fees ($) Add'l Fees ($) F Total ($) Balance r 620 0 620 O about:blank 1/1. FAc)(~oc)2-:~ EMCOM ELECTRONIC SYSTEMS, INC. CA LIC. 820216 SEC. LIC ACO 3838 256 WITHERSPOON WAY, SUITE H• ELCAJON, CA 92020 • PH. (619) 667-1200 • FAX (619) 667-1222 Fire Alarm Equipment Submittal For Cassia Heights Apartments 6480 El Camino Real Carlsbad, CA LCD DISPLAY FIRE ALARM CONTROL PANELS FA-300 SERIES Description Mircom's FA-300 Series fire alarm control panels consist of 6 and 12 zone models which are equipped with a two line by 20 character back-lit LCD display, numerical keypad and an integrated UDACT/Digital Communicator. The FA-300 Series family also includes remote LED and LCD annunciators as well as remote relay modules. The FA-300 Series panels are ideal for both new and retrofit applications. Designed for small to medium commercial, institutional and industrial occupancies, these panels are powerful enough to meet today's installation demands. The FA-300 Series panels are configurable by the keypad for onsite programming or by a PC for both onsite and remote programming. Easy to install and simple to operate and configure, the FA-300 Series panels enable the installer to configure the system to meet their specific requirements. The FA-300 Series panels are equipped with a 5 Amp power supply, 4-wire resettable smoke power supply (300mA max.), an interface for a Remote Trouble Indicator (RTl) and an RS-485 interface for remote LCD annunciators, LED annunciators and Remote Smart Relay modules. All FA-300 Series panels come complete with a red door, black enclosure, durable CAT-30 lock and key and space to mount up to 12 AH batteries. Optional trim rings are available for semi-flush mounting. Features Available in 6 and 12 zone models Integrated UDACT/Digital Communicator on select models Equipped with 2 line by 20 character back-lit LCD display and numerical keypad Front panel and PC programmable Remote upload/download capabilities Base panel is equipped with Class "B" (Style "B") initiating circuits which may be configured as Class "A" (Style "D") using a Class "A" converter module Initiating circuits may be configured as Alarm, Verified Alarm, Wateruiow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only Base panel is equipped with Class "B" (Style "B") indicating circuits which may be configured as Class "A" (Style "Z") using a Class "A" signal converter module Audible signals may be configured for Steady, Temporal Code, California Code and March Time Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test Subsequent Alarm, Supervisory, and Trouble operation RS-485 Interface for Remote LED Annunciators, LCD Annunciators and Remote Smart Relay Modules Interface for a Remote Trouble Indicator (RTI) Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events 5 Amp Power Supply Optional modules for additional internal relay circuits and City Tie/Polarity Reversal Optional trim rings for semi-flush mounting S7010 CATALOGUE NUMBER CC Col JUUL NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time Nithout notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Features Initiating Circuits The FA-300 Series panels are equipped with Class "B" (Style "B") initiating circuits. The initiating circuits may be configured as Class "A" (Style '0") using an ICAC-306 Class "A" converter adder module. Each Initiating circuit may be configured for one of the following modes of operation: Alarm (Without smoke detector verification) Verified Alarm (With smoke detector verification) Waterfiow Alarm (Water flow sensors) Sprinkler Alarm (Sprinkler flow sensors) Latching Supervisory Non-Latching Supervisory Monitor (non-latching input used mainly for correlating to a relay circuit) Trouble-Only (for monitoring a trouble condition from an external device) i3 Series Protocol The FA-300 Series panels have the i3 Series protocol built-in. The panels support the two-wire i3 Series smoke detectors (2W-1312WT-13). These i3 series detectors communicate with the FA-300 to provide the following status information: Open circuit trouble This trouble indicates that loop is broken. Communication trouble This trouble indicates that there is a fault in the line or the line is too noisy, the panel cannot communicate with the devices. Dirty device This trouble indicates that one or more device on the i3 zone is dirty. Out of sensitivity This trouble indicates that one or more device on the i3 zone is out of sensitivity range and cannot detect an alarm condition. Freeze trouble This trouble indicates that a device on the i3 zone has detected a freeze condition, e.g. the temperature is below 41°F / 5 °C (available only on model 2WT-B). The built-in protocol removes the need for the 2W- MOD Maintenance Module. Indicating Circuits The FA-300 Series panels are equipped with equipped with Class "B" (Style "B") indicating circuits. The indicating circuits may be configured as Class "A" (Style "Z") using an OCAC-304 or OCAC-302 Class 'A" signal converter adder module. The audible signals may be configured for Steady, Temporal Code, California Code and March Time. Each of the indicating circuits may be configured for one of the following modes of operation: Silenceable Signal Non-Silenceable Signal Silenceable Strobe Non-Sileneceable Strobe The FA-300 has built-in sync protocols for the following strobe manufacturer; Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock. UDACT/Digital Communicator The FA-300 Series panels are equipped with a fully integrated UDACT/Digital Communicator which allows for the reporting of events to a monitoring facility. The UDACT/Digital Communicator can be configured for single or dual line operation and uses the Security Industry Association (SIA) and Ademco Contact ID protocols. The UDACT/Digital Communicator is configured via the main display and keypad on the main panel. In addition to its reporting functions, the integrated UDACT/Digital Communicator can be used to connect to the FA-300 panel from remote computers for uploading and downloading of configuration data. It also allows for the viewing of the event history logs. The FA-300 series panels have two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events. The integrated UDACT/Digital Communicator can be configured for either DACT or UDACT operation. In DACT mode the Digital Communicator reports common alarm, trouble and supervisory information. In UDACT mode the Digital Communicator reports point specific information. CAT. 5662 ffl MC-0m NOT TO BE USED FOR INSTALLATION PURPOSES. page 2 of 6 FA-300 Series LCD Version Models FA-300-6DR Six Zone LCD Display Fire Alarm Control Panel The FA-300-6DDR is equipped with six Class "B" (Style 'B') initiating circuits and two Class "B" (Style "Y") indicating circuits rated © 1.7 Amps maximum. (Total of5Amps) One lCAC-306 Six Initiating Circuit Class "A" Converter Modules may be used for Class "A" (Style "D") wiring of the initiating circuits. One OCAC-302 Two Indicating Circuit Class 'A" Converter Module may be used for Class "A" (Style "Z") wiring of the indicating circuits. The cabinet will support up to 12 AH batteries. The panel can be semi-flush mounted with the optional FA-300TRB trim ring. Dimensions FA-300-6DR: 20"H x 14.5"W x 4.5"D FA-300TRB: 22.5"H x 17"W FA-300-6DDR Six Zone LCD Display Fire Alarm Control Panel with UDACT/Digital Communicator The FA-300-6DDR is equipped with six Class "B" (Style "B") initiating circuits and two Class "B" (Style "Y") indicating circuits rated @ 1.7 Amps maximum. (Total of 5 Amps) One lCAC-306 Six Initiating Circuit Class "A" Converter Modules may be used for Class "A" (Style "D") wiring of the initiating circuits. One OCAC-302 Two Indicating Circuit Class "A" Converter Module may be used for Class "A" (Style "Z") wiring of the indicating circuits. The FA-300-6DDR has a built-in UDACT/Digital Communicator and the cabinet will support up to 12 AH batteries. The panel can be semi-flush mounted with the optional FA-300TRB trim ring. Dimensions FA-300-6DDR: 20"H x 14.5"W x 4.5"D FA-300TRB: 22.5"H x 17"W FA-301 -I2DDR Twelve Zone LCD Display Fire Alarm Control Panel with UDACT/Digital Communicator The FA-301-12DDR is equipped with twelve Class "B" (Style "B") initiating circuits and four Class "B" (Style "Y") indicating circuits @ 1.7 Amps maximum. (Total of5Amps). Ore ICAC-306 Six Initiating Circuit Class A Converter Module may be used for Class "A" (Style "0") wiring of the initiating circuits. One OCAC-304 Four Indicating Circuit Class "A" Converter Module may be used for Class "A" (Style "Z") wiring of the Indicating circuits. The FA-301-I2DDR has a built- in UDACT/Digital Communicator and the cabinet will support up to 12 AH batteries. The panel can be semi-flush mounted with the optional FA-UNIV-TRB trim ring. Dimensions FA-301-I2DDR: 26"H x 14.5W x 4.5"D FA-UNlV-TRB: 28.5"H x 17"W CAT. 5662 W -R-C _0M NOT TO BE USED FOR INSTALLATION PURPOSES. page 3 of 6 Remote Annunciators RAM-300LCDR Remote LCD Annunciator The RAM-300LCDR provides LCD remote annunciation through a 2 line by 20 character LCD display. The RAW 300LCDR provides control switches for System Reset, Signal Silence, Fire Drill and Acknowledge as well as a numeric keypad to access the menu functions. The common control functions can be disabled on a per function basis. The RAM-300LCDR has LED indicators for A.C. On, Alarm, Supervisory, Trouble and CPU Fail. The RAM-300LCDR comes complete with a red enclosure and a CAT-30 Lock and key. SRM-312R Smart Relay Module The SRM-312 provides twelve configurable relay circuits, rated @ 28 VDC, 1 amp (resistive). Each circuit can be configured as a Normally Open (N.O.) or Normally Closed (N.C.) contact. Each relay is equipped with an LED that is lit when the relay is energized. The relays can be configured as relay per zone (1 to 1), Common on Alarm, Common on Supervisory or programmable for a logical or adjacent zone configuration. An adjacent zone configuration will turn on an adjacent zone when the configured zone is active. A chaining configuration allows for multiple relays to turn on. The SRM-3 12 is DIP switch configurable and connects to the RS-485 bus. The SRM-312R come complete with a red enclosure and a CAT-30 lock and key. RAM-208RIRAM-216R Remote LED Annunciators The RAM-208R and RAM-216R provide 8 or 16 points respectively of LED annunciation. Both models feature bi-coloured LEDs which are auto-configurable for either Alarm (red) or Supervisory (amber). The LED annunciators have indicators for A.C. On, Common Trouble and Signal Silence and control switches for System Reset, Signal Silence, Lamp Test and Buzzer Silence. The RAM-208R and RAM-216R are equipped with a keyswitch which allows for enabling and disabling of the Common Control functions. Both models are available in a red finish and mount in a 4-gang electrical box. RAM-1 01 6/RAM-1 01 6T Remote LED Annunciator The RAM-1016 Remote LED Annunciator provides 16 points of LED annunciation. The RAM-1016 comes standard with bi-coloured LEDs which are automatically configured for eitherAlarm (Red) or Supervisory (Amber). The RAM-1016 has indicators for A.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. In addition it allows for the control switches to be disabled on a per function basis. The RAM-1016TZ has the same features and provides individual trouble LEDs. Both models mount in a BB-1 000 series enclosure. RTI-I Remote Trouble Indicator Mircom's Remote Trouble Indicator provides remote annunciation of fire alarm troubles. The RTI-1 mounts onto a standard single gang electrical box. 011 • CAT. 5662 NOT TO BE USED FOR INSTALLATION PURPOSES. page 4 of 6 Adder Modules ICAC-306 Six Initiating Circuit Class "A" Converter Module The ICAC-306 converts six Class "B" (Style 8" initiating circuits on the FA-300 main board to Class "A" (Style "D") circuits. The ICAC-306 is equipped with wire leads to connect to the FA-300 main board. It mounts to the right of the main board Class "B" (Style "B") initiating circuits. Two ICAC-306 modules are required to convert all twelve initiating circuits on an FA-301-120DR series panel. OCAC-304 Four Indicating Circuit Class "A" Converter Module The OCAC-304 converts four Class "B" (Style "Y") indicating circuits on the FA-300 main board to Class "A" (Style "Z") circuits. The OCAC-304 is equipped with wire leads to connect to the FA-300 main board. It mounts to the right of the main board Class "B" (Style "Y") indicating circuits and is used with the FA-301-I2DDR series panels. OCAC-302 Two Indicating Circuit Class "A" Converter Module The OCAC-302 converts two Class "B" (Style "Y") indicating circuits on the FA-300 main board to Class "A" (Style 'Z") circuits. The OCAC-302 is equipped with wire leads to connect to the FA-300 main board. It mounts to the right of the main board Class "B" (Style "Y") indicating circuits and is used with the FA-300-6DDR series panels. RM-3061RM-312 Relay Circuit Adder Modules The RM-306 provides six configurable relay circuits, rated @28 VDC, I amp (resistive). The RM-312 provides twelve Form C configurable relay circuits, rated @28 VDC, I amp (resistive). On both models each circuit can be configured as a Normally Open (N.O.) or Normally Closed (N.C.) contact. Each relay is equipped with an LED that is lit when the relay is energized. The relays can be configured as relay per zone (11 to 1), Common on Alarm, Common on Supervisory or programmable for logical or adjacent zone configuration. An adjacent zone configuration will turn on adjacent zone when configured zone is active. A chaining configuration allows for multiple relays to turn on. PR-300 Polarity Reversal/City Tie Module The PR-300 provides outputs for city box and polarity reversal applications. As a city tie module the PR-300 provides an interface between the control panel indicating circuits and a master box. It provides off-premises signal transmission for systems that must comply with NFPA requirements for Auxiliary Protective Systems. As a polarity reversal module the PR-300 provides an interface between the control panel and a reverse polarity receiver. It provides off-premises signal transmission for systems that must comply with NFPA requirements. ELRX-300 Active End-of-Line Resistors The ELRX-300 are porsaving End-of-Line resistors which eliminates the need for an additional battery cabinet or larger batteries in orderto meet the 60 hour standby requirement. (P/ease refer to Battery Calculation Chart in manual for more details.) The ELRX-300 can also be used when larger batteries than can fit in the cabinet are required. The ELRX-300 are available with or without a mounting plate. CAT. 5662 11111k, MRS!! NOT TO BE USED FOR INSTALLATION PURPOSES. page 5 of 6 Specifications AC Input 120VAC @ 60Hz Standby Power 24VDC standby batteries Charging Capability 4 to 24AH Current Consumption: Standby: 283mA Alarm: 560mA Indicating Circuits Power limited / 24VDC unfiltered / 1.7A @ 49°C per circuit. Maximum 5 Amps. Ordering Information Model Description Aux supply (non resetable) Power limited / 22.3VDC regulated I 500mA max 4-wire smoke supply (resetable) Power limited/22.3VDC regulated / 300mA max Unfiltered supply (full wave rectified) Power limited / 24VDC unfiltered / 1.7A max at 49°C Auxiliary Relays (Common alarm/supv/trb/ and auxiliary second alarm) FormC I 28VDC I 1A max Control Panels FA-300-6DR Six Zone LCD Display Fire Alarm Control Panel FA-300-6DDR Six Zone LCD Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator FA-301 -12DDR Twelve Zone LCD Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator Remote Annunciators and modules RAM-300LCDR Remote LCD Annunciator (Red enclosure) RAM-300LCDW Remote LCD Annunciator (White enclosure) RAM-208R Eight zone Remote LED Annunciator RAM-216R Sixteen zone Remote LED Annunciator RAM-1016 Sixteen zone Remote LED Annunciator RAM-i O16TZ Sixteen zone Remote LED Annunciator with individual Trouble LEDs SRM-312R Remote Relay Module with red enclosure RTI-i Remote Trouble Indicator BB-1 001 R Red enclosure for RAM-1016/RAM-1 01 6T BB-1 001 Semi-Flush Stainless Steel Enclosure for RAM-10161RAM-1016TZ BB-i 001 WPR Red Semi-Flush Weatherproof Enclosure for RAM-1 01 6/RAM-1 01 6T TH-1 01 Heater Kit for use with BB-1 001 WPR Adder Modules ICAC-306 Six Initiating Circuit Class "A" Converter Module OCAC-304 Four Indicating Circuit Class "A" Converter Module OCAC-302 Two Indicating Circuit Class "A" Converter Module RM-306 Six Relay Circuit Adder Module RM-312 Twelve Relay Circuit Adder Module PR-300 Polarity Reversal/City Tie Module ELRX-300 Active End-of-Line Resistor ELRX-300R Active End-of-Line Resistor with red mounting plate Accessories FA-300TRB Black Semi-Flush Trim Ring for FA-300-6 enclosures FA-UNIV-TRB Black Universal Semi-Flush Trim Ring for FA-301-12 enclosures FA-300-DF Dead Front for FA-300-6DR/FA-300-6DDR FA-301-DF Dead Front for FA-301-12DDR UIMA Universal Programming Tool BA-1 04 12 Volt, 4 Ah Battery - 2 pcs required per panel BA-1 065 12 Volt, 7.2 Ah Battery - 2 pcs required per panel BA-110 12 Volt, 12 Ah Battery -2 pcs required per panel BA-117 12 Volt, 18 Ah Battery -2 pcs required per panel (Requires BC-I60 Battery Cabinet) BA-124 12 Volt, 26 Ah Battery -2 pcs required per panel (Requires BC-160 Battery Cabinet) BC-160 Battery Cabinet NOT TO BE USED FOR INSTALLATION PURPOSES. 1141,. ffi-mc-om C Canada U.S.A. 25 Interchange Way 60 Industrial Parkway, PMB 278 Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http:/Iwww.mircom.com Email: mail@mircom.com Distributed by: CAT. 5662 Rev. 1 FA-300 Series LCD Version Installation and Operation Manual Appendix D: Power Supply and Battery Calculations (Selection Guide) Use the form below to determine the required secondary power supply (batteries). IMPORTANTINOTICE The main AC branch circuit connection for Fire Alarm Control Panel must provide a dedicated continuous power without provision of any disconnect devices. Use #12 AWG wire with 600-volt insulation and proper over-current circuit protection that complies with the local codes. Refer to Appendix A for specifications. rPowerRequirements L I -Model Number Descrip tion _1nli P! and 'Alarm Total Alarm I Fire Alarm Control Panel, I I FA-301-12DDR 12 lnp, 40ut with UDACT X 0.174 = 0.444 = Using 3K9 resistors Fire Alarm Control Panel, FA-301-12DDR 12 lnp, 40ut with UDACT X 0.104 = 0.394 = Using active resistors Fire Alarm Control Panel, 6 FA-300-6DDR lnp, 2 Out with UDACT X 0.142 = 0.312 = Using 3K9 resistors Fire Alarm Control Panel, 6 FA-300-6DDR lnp, 2 Out with UDACT X 0.112 = 0.282 = Using active resistors Fire Alarm Control Panel, 6 FA-300-6DR lnp,2 Out without UDACT X 0.142 = 0.312 = Using 31<9 resistors Fire Alarm Control Panel, 6 FA-300-6DR lnp, 2 Out with UDACT X 0.112 = 0.282 = Using active resistors ICAC-306 Det Class A Converter 0.000 -0.000 0.000 -0.000 Adder Module OCAC304 Sig Class A Converter 0.000 -0.000 0.000 -0.000 Adder Module-4 Circuits OCAC-302 Sig Class A Converter 0.000 -0.000 0.000 -0.000 Adder Module--2 Circuits Polarity Reversal and City = 0.300 = PR-300 Tie Module X . 0.050 (City Tie in Use) RM-312 12 Relay Adder Module X 0.000 = 0.160 = RM-306 6 Relay Adder Module X 0.000 = 0.080 SRM-312 Smart Relay Module X 0.030 = 0.140 = RAM-300LCD Smart Remote Annunciator X 0.016 = 0.040 = RAM-208/216 Remote Annunciator X 0.035 = 0.090/0.140 = RTl-1 Remote Trouble Indicator X 0.035 = 0.035 = Two-Wire Smoke Detectors X 0.00011 = * 0.090 = 0.090 Four-Wire Smoke Detectors X = = Signal Load (bells, horns, strobes, and etc.) X = Auxiliary Power Supply for Annunciators, etc. = = Total currents (Add above currents) STANDBY (A) ALARM F (B) *Assume three Initiating Circuits are in alarm. 'Use 0.084 for five minutes of alarm or 0.5 for thirty minutes of alarm as a multiplier figure. .Using the MPD-65P 2-wire photoelectric smoke detector. Total Current Requirement:ALARM (B) Amps. (Value obtained from column B) Battery Capacity Requirement: ([STANDBY (A) I X [(24 or 60 Hours) ]) + ([ALARM (B) X ['Alarm in Hr.] ) = (C) ______AH Total Alarm Current: Must be 6 amperes or less for FA-300 Series, Indicating Circuits must not exceed 5 amperes. Battery Selection: Multiply (C) by 1.20 to derate battery. 69 Mircom Fire Alarm Panels Device Compatibility Guide FA-300 Series Compatible Two-Wire Smoke Detectors (UL Listed) Notes: Whether mixing different models of compatible smoke detectors or using the same model on the same circuit, total standby current of all detectors must not exceed 3 mA. The below listed smoke detectors are compatible with initiating circuits having Compatibility Identifier "A". Smoke Detector Compatibility Rated Standby Identifier Make Model/ Base Head / Base Current Smoke Dete r Compatibility cto Identifier Make Model / Base Head/ Base ,wl Hochiki System Sensor (cont'd) DCD-135/NS6-220 HD-3/1-113-72 0.035mA 2451TH/B401 A-A 0.12 mA DCD-135/NS4-220 HD-3/HB-3 0.035mA 2451TH / B401 A-A 0.12 mA DCD-135/HSC-220R HD-3/HB-3 0.035mA 4451HT/B401B A-A 0.12mA DCD-190/NS6-220 HD-3/1-113-3 0.035mA 4451 HT / B406B A - A 0.12 mA DCD-190/NS4-220 HD-3/HB-3 0.035mA 1100 A - N/A 0.12 mA DCD-190/HSC-220R HD-3/HB-3 0.035mA 1151/131101-P - A - A 0.12 mA SIJ-24/NS6-220 HD-3/1-113-72 0.040mA 1151/B116LP A-A 0.12 mA SIJ-24/NS4-220 HD-3/1-113-3 0.040mA 1400 A - N/A 0.10 mA SIJ-24/HSC-220R HD-3/HB-3 0.040mA 1451/13401 A-A 0.12 mA SLR-24/NS6-220 HD-3/1-113-72 0.045mA 1451/1340113 A-A 0.12 mA SLR-24/NS4-220 HD-3/1-113-3 0.045mA 1451/1340613 A -A 0.12 mA SLR-24/HSC-220R HD-3/HB-3 0.045mA 1451 DH/ DH400 A-A 0.12 mA SLR-24H/NS6-220 HD-3/1-113-3 0.045mA 2100 A - N/A 0.12 mA SLR-24H/NS4-220 HD-3/1-113-3 0.045mA 2100T A - N/A 0.12 mA SLR-24H/HSC-220R HD-3/HB-72 0.045mA 2151/13110LP A-A 0.12 mA SLR-835/NS6-220 HD-3/1-113-3 0.045mA 2151/13116LP A-A 0.12 mA SLR-835/NS4-220 HD-3/1-113-3 0.045mA 2400 A - N/A 0.12 mA SLR-835/HSC-220R HD-3/1-113-72 0.045mA 24001H A - N/A 0.12 mA SLR-83513-2 HD-6 55pa @ 24VDC 2451/13401 A-A 0.12 mA System Sensor 2451/13401B A-A 0.12 mA 4451HT/B401 A-A 0.12mA 5451/B401B A-A 0.12 mA 5451/13401 A-A 0.12 mA System Sensor i3 Series 5451/1340613 A-A 0.12 mA 2W-13 A 50 p 2451/B406B A-A 0.12 mA 2WT-B A 50 p 2451 / DH400 A - N/A 0.12 mA 2WTA-B A 50 pA 2451TH/B406B A-A 0.12mA 2WTR-B A 50 p ~il METAL FIRE ALARM STATION MS-70OU SERIES I I 1UII , . sL 7 7- PULIHANDLE rniuniin 1 MS-701 U Single Action Pull Station MS-71 ou Dual Action Pull Station Description Mircom's MS-700U Series Manual Pull Stations provide manual fire reporting. These high quality, die-cast metal pull stations are available in either single or dual action configurations with SPST contacts and terminal strip connections. The normally open contact, which closes when the pull station is activated, is rated for 1 amp, 30 VDC. The contacts are gold plated to avoid the risk of corrosion. The MS-700U Series Pull Stations are available in many different configurations as either single or dual- action devices. The MS-701U is a single action, single stage pull station. Model MS-710U is a single stage, dual action pull station. All models are available with key resets, terminal connectors, SPST gold contacts and CAT-30 lock and keys. The units mount on a standard single gang backbox, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox. Features Single or Dual Action Key resettable Terminal connectors Gold plated SPST contacts Optional auxiliary contacts High-gloss red enamel finish Plastic breakrod Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox Operation The MS-701U Single Action Pull Station is operated by pulling down the handle marked "PULL HANDLE" on the front of the station. The MS-710U Dual Action Pull Station is operated by pushing the bar labeled "PUSH BAR" and then pulling down the handle marked "PULL HANDLE". The MS-700U Series Pull Stations are reset by opening the station with the key, placing the handle in the normal upright position and re-locking the station. Specifications The manual pull station shall be Mircom's MS-700U Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the alarm detection circuit. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. PULL HANDlE @@ 10 S7005 S7005 7150-1477:128 _______________________________ CATALOGUE NUMBER W7' 5157 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications Switch Rating: Pull Station Dimensions: Surface-mount Backbox Dimensions: Color: l Amp @3OVDC 0.1 Amp @ 125 VAC 4.9" H x 3.5" W x 2.0" D 5" H x 3.6" W x 2.0" D Red with raised white letters, white pull bar with raised black letters. Typical Wiring Diagram MS-701U, MS-710U AND MS-712U FROM PREVIOUS STATION { FROM PREVIOUS STATION MS-712U ONLY TO NEXT STATION OR J END OF LINE DEVICE TO NEXT STATION OR J END OF LINE DEVICE MS-712U ONLY NOTES: WIRE AS SHOWN SO THAT SUPERVISION OF CONNECTIONS IS MAINTAINED. MOUNT STATION TO 2' a 4' a 2 1/4" OUTLET BOX. SWITCH RATING: ALL MODELS 1A@ 30VDC, 0.1A@ I25VAC MAXIMUM WIRE SIZE: No. 12 AWG. Ordering Information Model Description MS-701U Key Resettable Single Action Manual Pull Station MS-710U Key Resettable Dual Action Manual Pull Station MS-712U Key Resettable Dual Stage Single Action Manual Pull Station BB-700 Series 700 Interior Surface Mount BackboX, Red Finish BB-700WP Series 700 Weatherproof Surface Mount BackboX, Red Finish NOT TO BE USED FOR INSTALLATION PURPOSES, Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan. Ontario [4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com CAT. 5157 Rev, I - --- -V.----, Models Available Two-Wire Models 2W-B 2-wire standard 2WT-B 2-wire standard with thermal - - Four-Wire Models 4W-8 4-wire standard 4WT-13 4-wire standard with thermal - Accessories V 2W-MOD2 2-wire loop test/maintenance module -• _._____....j SENS-RDR Sensitivity reader RI Removal/ replacement tool -- A77-AB2 Retrofit adapter bracket - - Product Overview Plug-in detector line - mounting base System Sensor's i3" series smoke detectors represent a significant advancement in included conventional detection. The j3 family is founded on three principles: Installation ease, Intelligence, and Instant inspection. Large wire entry port In-line terminals with SEMS screws Installation ease. The 13 line redefines installation ease with its plug-in design. V . V This allows an installer to pre-wire the bases included with the heads. The large Mounts to octagonal and single-gang wire entry port and in-line terminals provide ample room for neatly routing the backboxes, 4-square backboxes, or wiring inside the base. The base accommodates a variety of back box mount- direct to ceiling ing methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug-in to the base with a simple Stop-Drop 'N Lock Stop-Drop 'N Lock' attachment to base action. Removable detector cover and chamber Intelligence. i3 detectors offer a number of intelligent features to simplify for easy cleaning testing and maintenance. Drift compensation and smoothing algorithms are standard with the 13 line, to minimize nuisance alarms. When connected to the Built-in remote maintenance signaling 2W-MOD2 loop test/maintenance module, or a panel equipped with the i3 protocol, 2-wire i3 detectors are capable of generating a remote maintenance Drift compensation and smoothing signal when they are in need of cleaning. This signal is indicated via an LED algorithms located at the module and the panel. To read the sensitivity of P detectors, the Simplified sensitivity measurement SENS-RDR is a wireless device that displays the sensitivity in terms of percent per foot obscuration. Wide angle, dual color LED indication Instant inspection. The P series provides wide angle red and green LED indica- Loop testing via EZ Walk feature tors for instant inspection of the detector condition, indicating: normal standby, out-of-sensitivity, alarm, or freeze trouble conditions. When connected to the Built-in test switch 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature MEA MSFM verifies the initiating loop wiring by providing LED status indication at each detector. LISTED approved approved S911 3011446 7272-1209:210 290-01-E 2093 Architect/ Engineer Specifications Smoke detector shall be a System Sensor P Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (model 2W-B, 4W-B) or a combination photoelectric/ thermal (model 2WT-B, 4WT-B) with ther- mal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring con- nections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug- in type. The detector shall have a nomi- nal sensitivity of 2.5% per foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (model 2W7-B, 4WT-B) conditions. When used in conjunc- tion with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical SDecifications Operating Voltage Standby Current Peak Standby Current Nominal: 12/24V non-polarized 2-wire: 50 pA maximum average 2-wire: 100 pA Mm.: 8.5V 4-wire: 50 pA maximum average 4-wire: n/a Max.: 35V Maximum Alarm Current . Alarm Contact Ratings Maximum Ripple Voltage 2-wire: 130 mA limited by control panel 2-wire: n/a 30% peak to peak of applied voltage 4-wire: 20 mA @12V, 23mA @ 24V 4-wire: 0.5 A @ 30V AC/DC LED Mode Green LED Red LED Condition Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Duration 80 seconds Physical Specifications Operating Temperature Range Sensitivity Mounting 2W-B and 4W-B: 32°F-120°F (01C-491C) 2.5%/ft. nominal 3/~inch octagonal back box 2WT-6 and 4WT-8: 32°F-100°F (0°C-37.8°C) - 4-inch octagonal back box Operating Humidity Range Input terminals 14-22 AWG Single gang back box 0 to 95% RH non-condensing 4-inch square back box with a plaster ring Dimensions (including base) Direct mount to ceiling Thermal Sensor 5.3 inches (127 mm) diameter 135°F (57.2°C) fixed 2.0 inches (51 mm) height Freeze Trouble Weight 2WT-B and 4WT-B only: 41°F (5°C) 6.3 02. (178 grams) Ordering Information Model Thermal Wiring I Alarm Current 2W-B No 2-wire 130 mA max. limited by control panel 2WT-8 Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12V, 23mA @ 24V 4WT-8 Yes 4-wire 20 mA @ 12V, 23mA @ 24V Model Description 2W-MOD2 2-wire loop test / maintenance module SENS-RDR Sensitivity reader RI Removal / replacement tool A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor - Far East 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 St. Charles, IL 60174 Fs: 905.812.0771 Fx: 86.29.8832.5110 Fx: 85.22.736.6580 Ph: 800/SENSOR2 Fx: 630/377-6495 System Sensor Europe System Sensor in Singapore System Sensor - Australia Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 www.xystemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 System Sensor - India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118 System Sensor - Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 10 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0318-005•6/04.#1280 Commander3 Series Selectable Candela Evacuation Signals Applications The Commander3 Series is a low profile strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable candela options of 15, 30, 60, and 75 candela. The Commander3 Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a chime as well as a whoop tone. All tones are easy for the professional to change in the field by using switches. The GE3 Series has a minimal operation current and has a minimum flash rate of 1 H regardless of input voltage. The Commander3 Series is shipped with the standard 4" mounting plate which incorporates the popular SuperSIideTM feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander3 also features the CheckmateTM - Instant Voltage Verification feature which allows the installer to check the voltage without removing the sig- nal. The GE3 Series appliances are UL 464 and UL 1971, listed for use with fire pro- tective systems and are warranted for three years from date of purchase. Standard Features GEC3/GES3 12&24VDC SERIES Product Listings IØc ®us This symbd o, tne pm,s na'nepto ,pns LIed by UNDERWRrrERS LABORATORIES. INC. a BFP (City of Chicago) BS+A/MEA #285-91-E CSFM 7135-0569:122 (GEC3-24 & GEH-24) 7125-0569:123 (GES3-24) 7125-0569:129 (GES3-1 2) 7135-0569:130 (GEC3-1 2 & GEH-1 2) UL 464 & UL 1971 Listed CANIULC S526-M87 Listed Nominal Voltage 12 & 24 VDC 24 VDC units have field selectable candela options of 15, 30, 60, 75, and 110 candela 12 VDC units have field selectable candela options of 15, 30, 60, and 75 candela GEH horn is available in 12 or 24 Volt Unit Dimensions: 5" high x 4.5" wide x 2.5" deep Prewire Entire System, Then Install Your Signals SuperSIideTM Bracket - Ease of Supervision Testing CheckmateTM - Instant Voltage Verification Lower Installation and Operating Costs Input Terminals 12 to 18 AWG Switch Selection for High or Low cIBA Switch for Chime, Whoop, Mechanical and 2400Hz Tone Switch for Continuous or Temporal 3 (not available on whoop tone) Tamperproof Re-entrant Grill Product Compliance NFPA72 Americans with Disabilities Act (ADA) PUMINA MEMBER FUR.I) DIE U." Surface Mount with the GSB (Gentex Surface Mount Box) Synchronize Strobe and/or Horn with AVSM Series Control Module (12 Volt product must use the AVSM Module). Silence Horn While Strobes Remain Flashing Wide Voltage Range 8-17.5 VDC (12 Volt Models) 16-33 VDC or FWR (24 Volt Models) Faceplate Available in Red or Off-White GEH 12 or 24 Volt Low Profile Evacuation Horn 1 Oft. Per UL 464, III, myl r.i tall tars GES3 12 or 24 Volt Selectable Candela Low Profile Evacuation Strobe fliod-eTilumbbf-----Pd-r-t-f%umilier-IJU~~ Candela (UL 1971) ___________________ME umam_____ VA RIM tXJVb 0 — = Wall Mount = Red Faceplate = Off-White Faceplate "P Plain (no lettering) Available with all models. These units are non-returnable. Agent bezel also available. GEC3 12 or 24 Volt Selectable Candela Low Profile Evacuation Horn/Strobe a la nde L MR901", In Anechoic Room ISIS PA2T1VJ" .0 ___________________ ____________________ t•I Meg - isIs Notes: The GE3 Series is not listed for outdoor use. • Operating temperature: 32°to 120°F (0° to 49° C). For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12 volt models are DC only. Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). GE3-12 Product Strobe Current Ratings I Candela 15cd 30cd 60cd 75cd voc 106mA 131 mA 186mA 237mA UL max- 163mA 212mA 331 MA 436mA GE3-12 Product Horn Current Ratings Horn Mode Minimum dBA @ lOft. per UL464 (HIGH) Minimum dBA @ lOft. per UL464 (LOW) Regulated 24VDC Max. Operating @ High Setting (mA) Temp 3 24001-1z 76 69" 29 Temp 3 Mechanical 75 68° 26 Temp 3 Chime 62° 60° 13 Continuous 2400H7 79 74° 29 Continuous Mechanical 78 77 26 Continuous Chime 63° 61° 13 Whoop 78 71* 55 GE3-24 Product Strobe Current Ratings Candela 15cd 30cd 60cd 75cd 110cd 24 VUU 55mA 63mA 88mA 112mA 136mA ULMax2 78mA 96mA 137mA, 180mA 224mA GE3-24 Product Horn Current Ratings Horn Mode Minimum dBA @ loft. per UL464 (HIGH) Minimum dBA @ loft. per UL464 (LOW) Regulated 24VDC Max. Operating High Setting (mA) Temp 32400Hz 78 71* 28 Temp 3 Mechanical 76 70° 25 Temp 3Chime 70* 66° 15 Continuous 2400Hz 81 74° 28 Continuous Mechanica, 80 72° 25 Continuous Chime 70° 66° 15 Whoop 82 69° 56 "Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode tire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for pub- lic mode application (not applicable when using the chime tone. The chime tone is always private mode), Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is oft is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw. The listed reverberant dBA are,tor the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA @ loft, per UL 464 is 77-83 with a horn current draw of 34mA. 2 PMS current ratings are per UL average AMS method. UL max current rating is the maximum FIMS current within the listed voltage range (16-33V0C for 24VDC units) (8.17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Mounting Super Slide" Switch Locations SWITCH POTION 3 . 5 'A-haM'.1 Jecnpl ON ON ON MechanclCont OFF ON ON HTrp. ON OFF ON HFCo,I, OFF OFF ON Chiee-Tornp ON ON OFF Chrn,e.Cont, OFF ON OFF Whoop ON OFF OFF OFF OFF OFF Switch Position 6 ON > HIGH dB OFF> LOW dB Switch positions 1 and 2 - in the off position to select - I isolated horn and strobe 1 power inputs. ILt U ON Checkmate' Instant Voltage Verification * A1 II IlL___- 1kI The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measure- ments will be taken using the S+ and S- locations although access is provided to other locations. NOTE: Care should be taken to not short the test probes. Candela Selection Conventional GES3/GEC3 Series Wiring Diagrams UL Listed j Signal S. S+ Panel S. H* I-I- Control Signal S+ S* S. H+ Supervised signal Circuit END OF U E RESISTOR 1 p. LENOOFUNE RESISTOR GEC3/GES3 Wiring Diagram GE3 Series with Gentex Synchronization Module F.A.C.P. I TO NEXT SIGNAL: clsN * WIRING ONLY - - -- 4.TO NEXT SIGNAL REMOVE JUMPER FORINDEPENDENT SYNCHRONIZED STROBE N. AUDIBLE SIGNAL OR To AND HORN OPERATION CIRCUIT c~" Rl.a ONLY. TO ELIMINATE NEED FOR HORN INPUT ON AVSM AND OPERATE SIGNAL IN UNISON MODE SYNCHRONIZATION MODULE VISIBLE SIGNAL CIRCUIT - TO NOTIFICATION ALARM CIRCUIT TO NOTIFICATION ALANGI CIRCUIT SYNCHRONIZATION MODULE LEAVE JUMPER IN PLACE ON SLAVE UNITS UNLESS SEPARATE ØØ CONTROL OVER HORN CAT IS REQUIRED. €50 OF 1J5n RES131OR FOR WIRING ONLY. Note: See Technical Bulletin 015 for proper synchronization module for application. Note: When synchronizing the GE3 12 VDC Series, the AVSM synchronization module MUST be used. Architect & Engineering Specifications: The audible and/or visible signal shall be Gentex GE3 Series or approved equal and shall be listed by Underwriters Laboratories Inc. per UL 1971 and/or UL 464. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 12 or 24V as measured in an ane- choic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the abil- ity to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 H or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 55mA or less at 24 VDC for the 15Cd strobe circuit and 106mA or less at 12 VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with termi- nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models or a voltage range of 8-17.5 volts for 12 volt models. The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 28 pounds per carton ImpotranI Nolice: These materials have been prepared by Gentex Corporation (GenIeo) for informational purposes only, are GE30201 -12 nncnsserily summary, and are not purported 10 serve as legal advice and should not be used as such. Gonleo me 'as no representations and warranties. express or implied. that these materials are complete and accurate up-to-date, or in compliance with all relevant local, slate and federal laws, regulations and rules The nmaIerial5 Cu mInI address all legal considerations as there is inevitable uncerlainly regarding interpretation allows, regulations and rules and ICY appliCalidn CI such laws, regulations and rules In partic- ular lad patterns. Each Iowan's activities can differently affect the obligations that exist under applicable lows, regulations or rules, Therefore. these materials should be used only (Or informational purposes and should not be AscIi as a substitute ICr seeking professional legal advice. Gentex will not be responsible lIlt any action at failure Iv act in reliance upon the information contained in this material. ci l'ri,mted on lncyclnd Pup,, Fire Protection Products: www.gentex.com 10985 Chicago Drive Box 310 • Zeeland, Michigan 49464 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax Ureter cn,IIxrotIa? crewel Ita righ' In make cha'mqes to ICC prOduCt uatn rhreIr at time discretlor,. GX9I & GX93 SERIES Product Listings cLus F Ths y°*rJ tee • mlx,.to ,,,0ns C Lewd by UNDERWRtTERS LABORATORIES, INC. BFP (City of Chicago) - BS+AJMEA #285-91 -E-X VI CSFM Listing 7135-0569:126 UL 464 Listed CANIULC S524-01/S525-99 Listed 1 MEMBER ASSERSLEO IN THE uc 40 - 12 or 24 VDC, Low Current Mini-Horn, Temporal (GX93) or Continuous (GX91) Tone with Terminal Blocks Applications The GX91/GX93 Series mini-horn is a high quality remote signaling appliance that offers dependable remote annunciation. The GX91/GX93 is listed for use with both filtered and unfiltered power. The GX91 is a continuous tone mini horn. This unit is not synchable with the AVS Series Control Module. It is however synchable from the panel. With the GX93 a jumper is provided to select either the continuous tone or the temporal 3 evacuation tone. The 0X93 can be used on the same sync circuit (AVS Series Control Module) as other Gentex signals. The GX91/GX93 appliances are UL 464 listed for use with fire protective systems and are warranted for three years from the date of purchase. Standard Features Single Unit is capable of 12 or 24 • Low Current Consumption VDC determined by the input • Variety of Mounting Options for New voltage Construction and Retrofit Applications Unit Dimensions: 2.84' wide x 4.48" • To Synchronize the GX93 use the high x 0.5" deep Gentex AVS Series Control Module Jumper Selectable Temporal 3 or (see Technical Bulletin 015) Continuous Tone on the GX93. • UL 464 Listed for Fire Protective GX91 has a Continuous Tone horn Service only • Textured Finish High Impact Plastic Horn Frequency is 3100Hz Faceplate, Available in Fire Alarm Red Terminal Blocks (12 AWG to 18 AWG) or Oft-White Available Models Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. Model Designations = Red faceplate Operating temperature - Indoor Use Only = Off-White faceplate I Indoor: 32° to 120°F (00 to 49°C) P' = Plain (iX91/GX93 Current Ratings Product GX91 GX93 24 VDC 15mA 22mA 24 VDC UL Max1 ilmA 18mA 12 VDC UL Max' 7mA 13mA Horn Mode Minimum dBA Minimum dBA Reverberant In Anechoic @ 10 Ft. Per © 10 Ft. Per dBA @ loft. Room dBA UL464@24V UL464@12V Per UL464 @lOft. Temporal 3 81 78 78-86 90 Continuous 86 83 78-86 90 1 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33V0C for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (I6VDC for 24VDC units) (8VDC for 12VDC Units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installtion manual. UL GX-93 I GX-93 I LISTED CONTROL I HLIH I I HEH PANEL + II SUPERVISED END OF LINE ff S IGNAL RESISTOR C I RCUIT \ RED RED RED RED e BLACK BLACK BLACK j BLAcK Wiring Diagram Mounting GX91 & G X 9 3 SERIES Architect & Engineering Specifications The alarm horns shall be Gentex Model GX91IGX93. The appliance shall be listed with Underwriters Laboratories for use with Fire Protective Signaling Systems and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber. The appliance shall be of solid-state construction and be polarized to operate from 8-33 VDC with a 15 milliamp current drain on the GX91 and a 22 milliamp current drain on the GX93 at 24 VDC. The appliance shall be provided with 2 terminals, and mount to a variety of single-gang back boxes. 24 units per carton 6 pounds per carton Important Notice: 1 r CT ' Ih"a matenals have been prepared by Gent Gentex Corporation Ge te ) for informational purposes ly ._ necxssarnlysunnnnnany. and are not purported ta serve as legal advice and should not be used as such. 551-0032-01 u L L _ LV \b. Gentex makes no representations and warranties, express or implied, that these materials are complete C C - ' 'rmrp fl 0 p and accurate up-to-date, or in compliance with all relevant local, state and federal laws, regulations and i1t rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation at laws, regulations and Riles and the application 01 such laws, regulations and rules to psrtic' Fire Protection Products. www.gentex.com ull r fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws. regulations or rules. Therefore, these materials should be used only for informational purposes and 10985 Chicago Drive Box 310 • Zeeland Michigan 49464 h ii I be used as substitute t seeking p lessona Hegl d will t b responsible to ac,ion or failu,P to act in reliance upon (he information contained in this material. 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax Gertet conponutinri revervrr thr nlgtll mc mate clrar.gei In tire picrluct data slrrmett 01 ItmnnIr tillcmetlonn C) Pn,ntrd air Oecyclrml Paymi A (yl 1pi.PeopleFakeActio SERIES MB MOTOR BELLS / H Description Wheelock's Series MB Motor Bells provide a better engineered motor bell for fire and life safety alarm . systems. The Wheelock Series MB Bells include higher .. ' dBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFl noise. The motor for Series MB Bells is a durable, high torque permanent magnet motor selected for its high SERIES MB RSSP performance and long life. REMOTE PLATE These DC vibrating Series MB Motor Bells are offered in 6" and 10" shell sizes in both 12 and 24 VDC models. Series RSSP Sync/Non-Sync retrofit plates are used in conjunction with the Series MB Motor Bell when combination appliances are required. The Series RSSP retrofit plates are available with either Multi-Candela or single candela strobes and easily mount to a 4" square or Wheelock SBL-2 backbox. All Series RSSP strobe appliances meet or exceed the requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard for Accessible and Usable Buildings and Facilities), ADA (Americans with Disabilities Act) and UL Standard 1971 (Signaling Devices for the Hearing Impaired). The Series RSSP retrofit plates may be synchronized when installed with the Wheelock Series SM, DSM, Sync Modules or the PS-1 2/24-8CP or PS-1 2124-8MP Power Supply with Wheelock's patented sync protocol. Wheelock's synchronized strobes offer an easy way to comply with ADA requirements concerning photo- sensitive epilepsy. Ordering Information Features Approvals include: UL Standard 464, Factory Mutual (FM), California State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) Meets OSHA 29 Part 1910.165 High sound output with low current draw Low frequency aluminum shells for better audibility through walls, doors and other structures 6" and 10" shell sizes in 12 or 24 VDC models Integral RFI suppression to minimize included noise on the NAC circuit Mounting options for surface, semi-flush, outdoor, and concealed conduit installation Built-in trimplate makes semi-flush mounting simpler and less expensive Screw terminals permit fast in-outfield wiring of #12 to 18 AWG wire Polarized for DC supervision of NAC circuits Operates on filtered or unfiltered DC For combined audible (bell) and visual signaling, convenient retrofit plate assemblies are available with Multi-Candela or Single candela strobes (Refer to Fire Alarm Products Catalog for Series RSSP Sync! Non-Sync Strobes specifications and technical information) Model Number Order Code Shell Size Input Voltage (VDC) Average RMS Current UL Max* dBA@ 10 Ft. Mounting Options MB-G6-12-R 3942 6" 12 0.060 0.090 92 D,E,J,K,N,O,P,R,S MB-G6-12-S 4221 6" 12 0.060 0.090 MB-G6-24-R 3941 6" 24 0.030 0.040 MB-G6-24-S 4222 6" 24 0.030 0.040 MB-G10-12-R 3944 10" 12 0.060 0.090 MB-G10-12-S 4223 10" 12 0.060 0.090 MB-G1 0-24-R 3943 10" 24 0.030 0.040 [MBG1024S 4224 10" 24 0.030 0.040 NOTES: Typical dBA at 10 feet is measured in an anechoic chamber. For bells all 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31.0 VDC. * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Copyright 2005 Wheelock. Inc. All rights reserved. Architects and Engineers Specifications The alarm appliances shall be Wheelock Series MB vibrating Motor Bells or approved equal. They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6" or 10' diameter. Sound output at 10 feet shall be 92 ciBA. The bells shall incorporate a permanent magnet motor and suppression circuitry to minimize RFl. They shall include a built-in trimplate for semi- flush mounting to a standard 4" square backbox, or surface mounting to Wheelock's indoor BB backbox or outdoor WBB backbox. For bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-Candela or Single Candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel. Model Number Order Code Nom Nominal Voltage (VDC) Strobe Candela Average Current (AMPS) at listed VDC UL Max* Mounting Options RSSP-24 MCW-FR 9402 24 15/30/75/110 .041/.063/.109/.140 .060/.092/.165/.220 D,E,Z RSSP-241575W-FR 7793 24 15 (75 on-axis) .060 .090 D,E,Z RSSP-121575W-FR 7798 12 15 (75 on-axis) .152 .255 D,E,Z * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Fig. 1 Bell Models Fig. 2 Retrofit Strobe AUDIBLE STROBE Plate Models (RSSP) fl I + + FROM PRECEDING FROM TO NEXT APPLIANCE OR FACP + ti APPLIANCE + OR EOLR ____________ __________ PRECEDING APPLIANCE { APPLIANCE } OR END-OF-LINE RESISTOR I I I OR FACP (EOLR) FROM 1.1 TO NEXT PRECEDING - STROBE OR STROBE OR + FACP + EOLR Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL). National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). 41 WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION ASSEMBLED IN THE USA NATIONAL SALES OFFICE 3 YEAR WARRANTY 800-631-2148 Canada 800-397-5777 E Mail Info@wheelockinc.com http://www.wheelockinc.com T±t Distributed By: 273 BRANCHPORT AVENUE 'LONG BRANCH, NJ 07740 • TEL: 732-222-6880 • FAX: 732-222-2588 S150002/05 Genesis Cable Systems Page I ot Honeyvvell Honeywell.com ACS - HOME ABOUT US PRODUCTS RESOURCES FEEDBACK LITERATURE CENTER CONTACT US FAQ ARTICLE 760 7777 - Fire Alarm Systems Riser Cables Unshielded Applications: Wiring of Fire protective signalling circuits, Code Restrictions: OK for use with all power limited circuits except those in plenums. Features: Available in 500ft or 1000ft Tangle-Free Boxes or Spools. Sequential Footage Markings. Construction: Copper Conductors, Genelene Insulation, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red. Conductor Color: Chart 4. Fire Alarm Jacketed Unshielded, Riser Rated 75DC AWG No. Sol Diameter Nom. Cap. Listings Avg. Wt. / Mft Part £ Cond. pf/Ft 22 4 Solid .122 15 UL, FPLR/CL2R, C(UL), FT4 15 (Lbs.) 4301 22 6 Solid .144 15 UL, FPLR/CL2R, C(UL), F14 19 (Lbs.) 4302 22 8 Solid .156 15 UL, FPLR/CL2R, C(UL), FT4 4303 22 10 Solid .182 15 UL, FPLR/CL2R, C(UL), FT4 30 (Lbs.) 4304. 22 12 Solid .188 15 UL, FPLR/CL2R, C(UL), FT4 4305 18 2 Solid .134 19 UL, FPLR/CL2R, C(UL), FT4 17 (Lbs.) 4306 18 4 Solid .170 19 UL, FPLR/CL2R, C(UL), FT4 34 (Lbs.) 4307 18 6 Solid .192 19 UL, FPLR/CL2R, C(UL), FT4 44 (Lbs.) 4308 -I 18 8 Solid .208 19 UL, FPLR/CL2R, C(UL), FT4 54 (Lbs.) 4309 - 18 10 Solid .244 19 UL, FPLR/CL2R, C(UL), FT4 67 (Lbs.) 4310 - 16 2 Solid .154 20 UL, FPLR/CL2R, C(UL), FT4 24 (Lbs.) 4311 16 4 Solid .184 20 UL, FPLR/CL2R, C(UL), FT4 43 (Lbs.) 4312 'I 14 2 Solid .184 22 UL, FPLR/CL2R, C(UL),. FT4 37 (Lbs.) 4313 -I 14 4 Solid .214 22 UL, FPLR/CL2R, C(UL), FT4 65 (Lbs.) 4314 - 12 2 Solid .214 22 UL, FPLR/CL2R, C(UL), FT4 55 (Lbs.) 4315 - + Spools Only *Consult Factory for Availability For Tchriical assistance call: Toll Free 800.222.0060 http://www.genesiscable.co--'producttemplate.asp?page=760.4a 6/3/2005 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1477:129 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Models FA-301-I2DDR, FA-300-6DDR, FA-300-6DR, FA-301-12LD (R) (W), FA-301-12L (R) (VV), FA-301-8LDW, and FA-301-8LW fire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU) services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: PR-300 RM-312 RM-306 SRM-312(R) (W) RAM-300LCD (R) (W) ICAC-306 OCAC-304 OCAC-302 ELRX-300 (R) (W) ELRX-300 RAM-216 RAM-208 Polarity Reversal and City Tie Module 12 Relay Adder Module 6 Relay Adder Module Smart Relay Module, Red/White Enclosure Remote LCD Annunciator, Red/White Enclosure Input Class A Converter, 6 Circuits Output Class A Converter, 4 Circuits Output Class A Converter, 2 Circuits Active End of Line Resister, Red/White Plate Active End of Line Resister, No Plate 16 Zone Remote Annunciator 8 Zone Remote Annunciator RATING: INSTALLATION: MARKING: APPROVAL: - NOTE: I20VAC, 60Hz In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 01-18-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 26, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1477:128 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Models MS-701U, -703U, 704U, -710U, -713U, -714U, 701ADU, -710ADU, *..7020 *..702ADu *..701up *..710up *..703u(c) *..704u(c) *..713u(C) *..714u(C) *..705u *j15u '-706U(C), *716U(C), *707U(C) and *..717U(C) fire alarm boxes. These devices are manually actuated, single or dual action non-coded, fire alarm boxes for indoor use only. Units are to be mounted on standard outlet boxes or listee's Model BB- 700 backbox *for indoor use only and *BB..700Wp backbox for indoor and outdoor use. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC, 1A, 125 VAC, 1A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev 12-02-2005 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: DECEMBER 2, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:152 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Lin hart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2Wr-B and 4WT-B employ a thermistor type heat sensor (1350 F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 20, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0569:122 Page 1 of 1 CATEGORY: Audible Devices LISTEE: Gentex Corporation, 10985 Chicago Dr., Zeeland Ml 49464 Contact: *Keiffer Sestric (616) 392-7195 FAX (616) 392-4219 DESIGN: Model GEH24 horn and Models HS24-15, HS24-15/75, HS24-30, HS24-60, HS24-75, HS24-110, GEC24-15, GEC24-15/75, GEC24-30, GEC24-60, GEC24-75, GEC24-110, GEC24-177, GCC24-C, GEC3-24 and WGEC1638-75 horn strobes. May be followed by - W (wall) and -w or -R (white or red) or -P plain. Models GCC24-C horn/strobe are ceiling mounted followed by -R (red), -W (white) or -P (plain). Refer to listee's data sheet for additional product description and operational considerations. RATING: Electrical: 24 VDC Candela: 15cd, 15/75cd, 30cd, 60cd, 75cd, 110cd, 177cd. GCC24-C Ceiling: 15cd, 30cd, 75cd, 95cd 115cd (selectable) GEC3-24 Wall: 15cd, 30cd, 60cd, 75cd, 110cd (selectable) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings and UL label. APPROVAL: Listed as horn and horn/strobes for use with separately listed compatible fire alarm control units. For indoor use only. Model WGEC1638-75 is intended for outdoor use when used with Model GOE outdoor enclosure (CSFM Listing No. 7300-0569:124). Model WGEC1638-75 is intended for private mode signaling use only. Nat approved for hearing impaired application. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. *Rev. 12-09-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 9, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0569:123 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Gentex Corporation, 10985 Chicago Dr., Zeeland Ml 49464 Contact: Keiffer Sestric (616) 392-7195 FAX (616) 392-4219 DESIGN: Models ST24-15, S124-15/75, ST24-30, ST24-60, ST24-75, ST24-1 10, GES24-15, GES24-15175, GES24-30, GES24-60, GES24-751 GE824-110, GES24-177, and GES3- 24 strobe lights; followed by suffix -w (wall mount), followed by -W or -R (white or red). Intended for indoor use and wall mount only. Model GCS-24 strobe light; followed by W or R (white or red color) and P (plain). For indoor use on wall or ceiling mount. *Model AVSM Sync Module intended for indoor use with Gentex synchronizable strobe lights. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Candela: 15cd, 15cd & 75cd at 00 angle axis 30cd, 60cd, 75cd, llOcd, 177cd. Model GCS24: Selectable 15cd, 30cd, 75cd, 95cd and 115cd Model GES3-24: Selectable 15cd, 30cd, 60cd, 75cd and 110cd Electrical: 21-30 VDC *Model AVSM: 8-33 VDCNFWR Flash Rate: 60 flashes per minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical and candela ratings and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired for use with separately listed compatible fire alarm control units. *Rev. 02-03-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 9, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7135-0569:126 Page 1 of 1 Audible Devices Gentex Corporation, 10985 Chicago Dr., Zeeland Ml 49464 Contact: *Keiffer Sestric (616) 392-7195 FAX (616) 392-4219 Model GX91 and GX93 horn. Model GX-93 has selectable continuous or temporal tones. Refer to listee's data sheet for additional product description and operational considerations. Electrical: 8-33 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, model number, electrical ratings and UL label. Listed as horns for use with separately listed compatible fire alarm control units. For indoor use only. Unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. *Rev. 12-09-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or .. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 9, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0785:113 Page 1 of 1 CATEGORY: Audible Devices LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Model MB series bells and Model MBS series bell/strobes. Models MB are suitable for outdoor use when used with Model WBB backbox. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. Rev. 12-08-97 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 21, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1487:100 Page 1 of I CATEGORY: Cables-Fire Protective Signaling LISTEE: Genesis Cable System, 7701 95th Street, Pleasant Prairie, WI 53158-2716 Contact: Orville Allen *(262) 947-0720 Fax (262) 947-0724 DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HDPE or LDPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT-45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, Type "FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. *Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. A REND, Senibr Deputy Program Manager