6971 EL CAMINO REAL; ; FS140014
9/19/24, 2:48 PM FS140014 Permit Data City of Carlsbad Fixed Systems Permit 6971 ELCAMINO Job Address: REAL Permit Type: FIXSYS Parcel No: 2150507200 Lot #: 0 Reference No.: Permit No: FS140014 Status: APPROVED Applied 5/1/2014 Approved: 5/6/2014 Issued: 5/6/2014 PC #: Inspector: Project Title: BEACH PLUM KITCHEN ANSUL 6.0 GALLON SYSTEM TO (2) 3.0 MAN IFOLDED TANKS Applicant: V FIRE SYSTEMS CORPORATION P0 BOX 13278 SAN BERNARDINO, CA 909-398-1591 Owner: PLAZA PASEO REAL ASSCS L L C C/O MADISON MARQUETTE 2001 PENNSYLVANIA AVE NW 10TH FLOOR WASHINGTON DC rI Fees I($) Adcf I Fees ($) Total ($) Balance ($) 149 0 149 I 0 about:blank 6N' CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue -- Carlsbad CA 92008 760.602.4665 .WET CHEMICAL EXTINGUISHING SYSYTEM - ACCEPTANCE TESTING Project/Business Name: Contact: Phone: Address: 417( (''4fA 37: Suite. 2e Carlsbad, CA Zip: 13 Installing Company V.- re,c(c Op CLN: 77''? /3 Phone: 107-66 Monitoring Company: 0 Phone: Account# DRAW A LINE TROUGH THE BOX IF THE LINE ITEM DOES NOT APPLY TO THIS PROJECT. ITEMS CIRCLED ARE ITEMS THAT NEED CORRECT OR ARE DUE. '- Approved "job copy" of the fire protection system plan & permit are provided and maintained on site. (17A 4-1) Contractor's technician on scene shall produce a valid "permit" from the State Fire Marshal's Office. 6—An "inspection report" which includes all items is provided, fully completed, and signed by the "permitee". (For new systems drawing is a required part of this documentation) One copy of the inspection report is provided to the owner. A new "standard service tag" is attached to the system, and any previous tags have been removed. A copy of the manufacturer's listed installation and maintenance manual OR listed owner's manual has been provided to the owner. (17A:4-3.3) B—A signal is provided to show the system has operated. (17A 3-2.1.5) ON A minimum of one pull station is provided; in the path of egress; located <4 feet above the floor. (17A 3-2.1.6) 41(--Wet chemical containers and expellant gas assemblies are located in an environment with temperature ratings within d,C manufacturer's listed temperature ranges. (17A 3-4.1) Manual activation devices are identified as to the hazard they protect. (17A: 2-4.2.3) Wet chemical containers and expellant gas assemblies are located where they are not subject to damage. (17A 3-4.2) At Containers shall be-accessible for inspection, maintenance and recharge. (17A: 3-4.3) Nozzles are connected and secured such that they will not be readily put out of alignment. (17A 3-5.2) Discharge nozzles are provided with a listed cap or other suitable device to prevent entrance of grease vapors or moisture. (17A: 2-3.1.4) 9—If suppression system protects more than one hood it complies with section 3-6. See NFPA 17A: 3-6 for requirements. (17A 3-6) tm..... At least one fusible link or heat detector is provided above each cooking appliance (or group of appliances protected by a single nozzle.) (17A: 3- 6.1.2) c All piping is non-combustible and no galvanized piping is used. (17A:2-5.1) c(. Listed devices seal all piping and conduit penetrations of hood. (17A 3-6.1.3) es— Power / fuel shut offs - All electric power or fuel to cooking appliances under the hood shall be shut down when the system is activated. (17A:2-4.3.1) Electrical connections (such as for fuel shut offs) shall NOT be made in the control head or mechanical release cabinet. (They should be in a separate junction box.) (Installation of these connectors inside the control head or mechanical release cabinet subjects them to mechanical damage when control mechanisms operate.) (17A: 2-7.1, NFPA 70) Direct power connections for make-up air fans or appliances are not connected directly to system micro-switches. (They are for control voltage only.)( 17A:2-7.1, NFPA 70) Make-up air fans that are integral to the hood SHALL shutdown upon system activation, unless listed otherwise. Exhaust fans SHALL continue to operate after system activation. Non-integral make up air may continue to operate after activation. (NFPA 96: 5-2.3 and 5-3) Vh( building or area is provided with a fire alarm, activation of the system shall activate the fire alarm system. (NFPA 96, 7-6.2) LAST detector in a line is tested by replacing with a test link and cutting link. Note: This requirement is normally found in the manufacturer's installation manual. (17A: 4-3) "puff test" or other process is performed to verify that the system piping and nozzles are free and clear of any obstructions. Note: Procedures for this or a similar test are normally found in the manufacturer's installation manual. Test discharge of wet chemical is NOT required by this agency. 17A: 4-3) 41'All detector (fusible link assembly) brackets are secured on both sides, not one. Note: This requirement is normally found in the manufacturer's installation manual. See Ansul R-102 manual, page 5-8, figure 16 for one example. The installer is required by statute to install the system in accordance with manufacturer's instructions. (NFPA 96: 7-2.2.1) Class K fire extinguisher is mounted within 30 feet of the cooking equipment and is equipped with a sign (NFPA 10: 10.2.2 and 96:7-2.1.1) telling users to activate fixed suppression system prior to use of extinguisher.. (NFPA 1, 7-6.3.7; NFPA 10, 3-7) 0 NOTES: F-FfFG systems Ii'c. L--;Bv IWPPFG5Sff0L:,7 oi b?&r c iafl?c9 017 UL 300 Smwrewiaa Susten (sr;t 13e,ci7' /%Uk11 JsA2res (9 7J (/s4id1 1' ?'o9 Job Humber 1 'Y 7' Type of System: Annul R4 02 [V Annul Piranha 0 Ccptive1Aire CORE 0 Pyro Chem El Other________ Rm 2yeeam. 05striDn2w5-1]6 SYST12MS VC. Comy Renp V f/ k' System Iflode2 /Z/'2 25 Iddress -,Serial Plufnbe;______ Fue!1Eiy Shut O? Device Gas Valve: Mechanical [441ectricai 0 Size_______ tnStI3:23d. Tested ea Shunt Breahec V' D3 This Fire Sup cssom System is inctelled in accordance with the Manufactures instructions and dmuAngas !FPA 96 cad 17 (adopted issues) and ci] applicable state and local codes. All eectricaI mmrti or =TN jpwkmcaS by others to cotfete the installation of this system has been completed. Ecetrns to the above are noted Wow. (Use bach of sheet if necessary) bO Ecms (22/2i c4v;T7?</42f7 7)/Mlf P60,4-ie-4 Utcve received a copy of the Fire Suppression System Owner's Manual and I understand it. I also u,ndwztcnd thst it is the reconuteadc2oa of the Motional Fire Protection Association (FPA) that the system be inspected eeiy oin nonIfts to maintain its reliability. ©'t2y C70 Jcctic Fem2ioncV tests have Risi essed and the system nerforms as Pht amte 4 4E\J 4,4J Jurisdiction ______________________