Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6221 METROPOLITAN ST; ; FA090002; Permit
12/13/24, 4:11 PM FA090002 Permit Data City of Carlsbad Fire Alarm Permit 6221 Job Address: METROPOLITAN ST Permit Type: FALARM Parcel No: 2132600100 Lot #: 0 Reference No.: Permit No: FA090002 Status: ISSUED Applied 1/5/2009 Approved: 1/5/2009 Issued: 1/5/2009 PC #: Inspector: Project Title: BRESSI RANCH MEDICAL PLAZA TWO FIRE ALARM INSPECTIONS @ $65 EA Applicant: STANDARD ELECTRONICS 9340 STEVENS RD SANTEE CA 6197596-9950 Owner: BRESSI RANCH MEDICAL PLAZA L L C DAVID DIRIENZO 1280 BISON AVE #139-609 NEWPORT BEACH CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 130 0 130 0 about:blarik 1/1 (if Standard Electronics 9340 Stevens Rd., Santee, CA 92071 (619) 596-9950 FAX 596-8850 BRESSI RANCH MEDICAL PLAZA FIRE ALARM SYSTEM SUBMITTAL APPRr,S s 7v Ila CARL AD RE1 FA OcDOOI2- Standardj November 24, 2008 ics Electronics 9340 Stevens Rd. Santee, CA 92071 Ph# 619-596-9950 Fax# 619-596-8650 SUBMITTAL SHEET PROJECT: BRESS1 RANCH MEDICAL PLAZA, 6221 METROPOLITIAN ST, CARLSBAD, CA 92008 ELEC.CONTR: SASS ELECTRIC, 11657 RIVERSIDE DR, #165, LAKESIDE, CA. 92040 EQUIPMENT FIRE ALARM SECTION ITEM QTY DESCRIPTION MODEL NO. DATA SHEET MICROPROCESSOR CONTROL PANEL 1 1 SFM #7170-0900:148 10070R1 FIKE 2 2 12 VOLT 7AH SEALED LEAD ACID BATTERIES ES7-12 FIKE ADDRESSABLE OUTPUT MODULE 3 3 SFM #7300-0900:140 55 043 FIKE ADDRESSABLE PULL STATION 4 1 SFM #7150-0900:144 20 1063 FIKE ADDRESSABLE MONITOR MODULE 5 6 SFM#7300-0900: 140 55045 FIKE ANALOG PHOTOELECTRIC SMOKE DETECTOR 6 3 SFM#7272-0900: 139 63 1052 FIKE ANALOG HEAT DETECTOR 1350 7 1 SFM#7270-0900: 141 60 1039 FIKE PLUG-IN BASE, FLANGED, 6.2 INCH DIAMETER 8 4 SFM #7300-0900:138 63 1054 FIKE 14 AWG/ 2 CONDUCTOR - SOLID CONDUCTORS POWER LIMITED - OVERALL JACKETED - FIRE PROTECTIVE 9 1K SIGNALING CABLE #994 WEST PENN SFM #7161-0859:101 16 AWG/ 2 CONDUCTOR - SOLID CONDUCTORS POWER LIMITED - OVERALL JACKETED - FIRE PROTECTIVE 10 ..5K SIGNALING CABLE 9990 WEST PENN SFM #7161-0859:101 16 AWG/ 2 CONDUCTOR - SOLID CONDUCTORS POWER 11 1K LIMITED - FIRE PROTECTIVE SIGNALING CABLE #AQ225 WEST PENN SFM #7161-0859:101 IThese plans have been re viewed for appawnt cotop with the current applicable codes and standards in iorce in the jurisdiction. The-owner or contractor may utilize his review in support of an application for a huildine rnnt with the express understanding that this recww in no way relieves the owner or contractor or their prolssional engineer or architect for sole responsibility for full compliance with said codes and standanls. including the building code or for any responsihilty for deficiencies, errors. omissions or negligence in these plans whethL'r or not noted in this review. Date: /2//9" Reviewer4.) M RECOMMEND APPROVAL 11 RECOMMEND APPROVAL. AS NOTED AKE CYBERCATTM 50 INTELLIGENT ARE ALARM CONTROL SYSTEM DESCRIPTION . .. . . . . .. Fike's CyberCat 50 (P/N 10-070) is a statc-of-the-art true intelligent digital peer- . to-peer modular fire alarm control system. It is ideal for all life safcty and propci y protection applications and is intended for both commercial and industrial use. his designed with extensive programmability that allows the almost-instantaneous relay of information and the ability to perform process management tasks with ease including shutdowns, HVAC, Voice Evacuation 'Systentis, Dampers, Doors, Elevators, and Security, CCFT/Building Management Awreriess, This cost-effective panel comes standard with one Signaling Line Circuit (SLC) that supports 50 devices. The 50 devices may be any mix and match of sensors. and modules. Th'e'CyberCar 50 utilizes extreme intelligence via: its eclipse. based sensors including photoelectric, photoelectric with heat, ionization, photoelectric duct, and heat detectors. It also utilizes EclipseTM based modules such as the monitor, mini-monitor, relay, intelligent pull station and control modules. With CyberCat 50 every device cOththunicates as a peer on the signaling 1iie circuit. These, peers not only communicate up-to-the-second information to the control JPWWJ1 I panel, but also communicate with cach,other. hach device is capable of generating . accurate and highly, detailed information. ,Cpnventional fire alarm.ystems give a . . Fike CyberGat 50 ••. general idea of the fire's location, while the CyberCat 50 intelligent sensors indicate precisely which devicis in an alarm state. This intelEgaice provides incredible ' APPROVALS . , speed.with response times as 1tdc as one-quarter second, between manual pull UL S2203 station and notification appliance. 'Its flexibility, allows you to attach the intelligent - . FM 3029134 devices that are required for your specific application. ' The System is programmed with either the Windows. based field configuration sofrrare GIANXThl or through a comprehensive password protected front-panel keypad programming options. This option allows you to quickly update and adapt to any future requirements or changes in the system such as. changes in occupancy.or . . . . .. remodeling. The sophisticated control panel circuitry coupled with the software allows you to read specific information and sensitivity levels of the different Eclipse devices The sensors also compensate for any changes clue to age, contamimstion, or other environmental factors. System Operation The CyberCat 50 Control system operates on a "Zone and State" relationship. In this design, all input and 'output devices must he assigned to at least one zone or to all zones (254 are available), each one defining an area to be protected. Input devices can be assigned up to 253 zones (one zone is typical) and 'output devices may be configured for up to 254 zones. These devices use the SLC signaling line circuit to exchange status information with other devices as well as with the control panel. When an input is activated, it is configured to cause its associated zone to enter into an operational state. Any detection device will cause its associated zone to enter into an alarm state. The output devices are configured to activate to protect and evaluate the endangered zone. This system is completely modular, allowing you the flexibility to design a system that is just right for your application. A typical configuration is shown on page 2 that illustrates the communications of a CyberCat 50 system. Form No. D.1.19.O1-1 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. . (816) 229-3405 . () 229-4615 'ww.fike.com -.1 P,ot&, DceC1Or tJAC Module 'i o,.rrnr,rndc T•-' :• V . 'Tu,ison and n( "'A— globes Canabkd of ii . .qcf,mo*0 nd 1nIay Mocful pulorinS Proc5s Marlagorncr)l Tasks Such As: 'luib, oicet. u;! or Systems MAC 'cc .JJ.I'II ' of II I... .,. cc!.' :crv..ui t. ci 0 ,flç.... cc., d Doos STANDARD FEATURES/SPECIFICATIONS The Cyhercat features are designed to save lives and protect your valuable capital investments through unprecedented speed, intelligence and flexibility. These features include: General Two Class A or B 24VDC, 1.75A NAC (bell) circuits on main board with built in System Sensor or Gentex synchronization protocol 254 user defined zones 80 character, hacidit LCD display Real time clock 3200 event history buffer Critical process monitoring One-perspnWalktestcpabilttv..........., .. _., .. .. Disable by circuit or zone or device Drill function at panel and remote Provides solenoid releasing operation Alarm verification Easy to add/remove devices Diagnostic menus. Local piezo with distinct event tones 10 Status LEDs to easily identify system status Built-in point ID I)ACT Module Supports up to 31 peripheral devices such as Remote Display, LED Graphic,Zone Annunciators, Ethernet Modules and Multi-Interface Modules USB port for programming Page 2 STANDARD FEATURES/SPECIFICATIONS (Continued) Power 5.25 amps useable alarm power Operation from I20VAC/60 Hz or 240 VAC/50 Hz Two 24V DC, 2A continuous auxiliary power outputs Supports up to 75AF1 of batteries Signaling Line Circuit Address devices with Infrared (ER) tool, similar to remote control device One SLC loop, NFPA style 4,6 or 7 50 devices, any mix and match of sensors and modules True peer-to-peer digital protocol for extremely fast and reliable communications Auto address function Automatic day/night sensitivity adjustment Automatic holiday sensitivity adjustment Acclimate operation for sensors JR Tool provides ability to read sensitivity levels or perform remote test of device Devices contain multi-color LED for quick reference of device status Sensors provide early warning pre-alarm detection and can also provide a summing feature (up to eight sensors) NAC Circuit Two NA.0 circuits standard Rated at 24VDC, 1.75 Amps maximum Class A or B Built-in synch protocol for System Sensor®, and Gentex® devices CONTROL SYSTEM MODULES Cybercat 50 Controller (P/N 10-2620) The Controller contains the power supply, microprocessor, hardware interface, display and keypad. The controller's internal power supply provides 2 Amps Normal Standby Current/5.25 Amps Alarm Current. Enclosure Steel Enclosure 22.1" H x 14.35" W a 4" D (Back-box dimensions) Enclosure is equipped with a 0.50" wide lip to facilitate flush mounting . Removable door for ease of installation .Available in red or black .........................................................--. ......................................................................................................... Dead Front option available Point ID Dact (Digital Alarm Communicator Transmitter) Module (P/N 10-2528) The DACT provides interface with Central Station monitoring systems. it is available with 5 contact zones of connection OR the intelligent serial interface which provides point Ii) information. The Contact Ii) form is the preferred reporting format. It provides a four digit account code followed by a three digit event code, a two-digit group number, and a three digit contact number, all of which are used to provide specific point identification. This DACT can also provide an SIA or 4/2 Pulse reporting format. Note: 10-2476 is same as 10-2528 with enclosure for external mounting. This is included in all 50 Point CyberCats Panels. Page 3 CONTROL SYSTEM MODULES (Continued) 14 Button Remote Display Unit (P/N 10-2646) The Pike fourteen button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The FRD is provided with a 80 character, backlit display which performs two display functions. First, it duplicates information provided by the control panel. Additionally the FRD has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. The FRD also includes six keys (Enter, Escape, +1-, left/right arrow) that are used for navigation through events as well as configuration of the device. Additionally it has eight programmable buttons that can be configured for things such as reset, silence, acknowledge, drill, or process. A key lock is included for additional security access. 10 Button Remote Display Unit (P/N 10-2631) The Fike ten button remote display (FRI)), provides remote annunciation of Pike's intelligent control panels. The FRD is provided with a 80 character, backlit display which performs two display functions. First, it duplicates information provide d by the control panel. Additionally the FRD has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. The FRD also includes six keys (Enter, Escape, +/-, left/right arrow) that are used for navigation through events as well as configuration of the device. Additionally it has four dedicated buttons that perform the following functions: drill, silence, acknowledge, and reset. A key lock is included for additional security access. 2 Button Remote Display Unit (P/N 10-2630) The Fike two button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The FRD is provided with an 80 character, backlit display which performs two display functions. First, it duplicates information provided on the main control panel. Additionally, the FRI) has the capability of viewing system conditions such as alarm, trouble, supervisory, etc. Pike Zone Annunciator (P/N 10-2373) The Zone Annunciator provides instant visual status of up to 10 zones of fire protection. Each zone has a red Alarm LED and yellow Trouble/Supervisor)' LED. Each LED is individually programmable for zone(s) and state(s). Each LED can he labeled using Avery Label 6467 or 5418. It is intended to be powered via the CyberCat 50 panel 24VDC auxiliary power. It communicates with the main control panel via RS485 communication. The annunciator provides the capability to remotely reset, silence and acknowledge the main control panel. Security to the unit is available via the standard Fike key. It mounts to a 5 gang masonary box Raco 694). The unit can then be surface or flush mounted. The following system modules are available for the CyberCat Control System: Fike Ethernet Module (P/N 10-2627) This Module provides the ability to remote monitoring of multiple CyberCat 50 panels via Ethernet/IP. This module is connected to the CyberCat 50 via the peripheral connections at PC and will be configured as a peripheral device. In order to utilize the remote monitoring capability, a network ID must be assigned to each panel for identification purposes. This module connects to the Panel at P6 per ± and also requires 24 volts .DC from the panel to l'C 24A ±. Sec the. 06-388 Ethernet Module manual for more details. Pike Multi-Interface (P/N 10-25.83) . . . .. The primary function of the multi-interface module is that it is used as a printer interface for the CyberCat control panels. It provides specific event and point information to be communicated from the panel to the printer. It is compatible with either a Epson FX-890 or equivalent IEEE 1284 standard printer or for EL required applications the Keltron 90 series UL listed fire alarm printer. Page 4 CYBERCAT/PROGRAMMING CONFIGURATION Software All configuration variables can be assigned using C-.LINX software. This software provides the designer the capability to provide a pre-engineered design. The user can review the construction plans to assign the zones. The configuration can also be set to identify the exact device circuit operation desired along with the custom message information. JR Configuration Tool This optional hand-held infrared remote control is available on the CyberCat system. This small device can be used in the field to simplify installation, testing and service. It operates with 2 AA batteries and can read device information such as loop, address, branch and service dates and initiate device test. This tool: Communicates hi-directionally with any CyberCat device Easily addresses devices by setting the loop and address Quickly reads sensitivity levels, date serviced, device type, loop and address, manufacture date Immediately records the date serviced instantly initiates walk test of any setsof or module Accesses and tests hard-to-reach sensor or module (such as duct detector) through any other device on loop Field Wiring Although the installation instructions provided for each module should be used for installation, please sec the a general wiring diagram on the following page. Wiring Specifications Maximum Resistance: 70 ohms Maximum Capacitance: .06 uf 12,000 ft. maximum distance total from panel to last device. FIELD WIRING DIAGRAM ol1r'1 oL____________ LJLJ ____ LEtTL] 1 ItIe'I I I 1 1i fl 11 lILJI!J I I z4ocMrnuN,yllL,i51 III wwtn P2 .P2 Pi —Dbpiy A1-44W €L..5Q PONT PAW ...I FM CWMTO I ::cCA03/5 AL /25 I —. ,, +•— J L. cD E _ E • £1 Page 5 ORDERING INFORMATION - FIKE P/N - Description lndividiialDatasheet # 10-070-c-p or 10-070-c-p-d CyberCat 50 System, includes Controller, Enclosure, and Transformer c; (R=R(..,d, E3'BIack) p: (1=120V, 2= 240V) d=Deadfront 0.1.09.01 10-2620 CyberCat 50 System Controller (included and _with _10-066-c-p_ _—L) D.1.09.1 10-2519-c Dead Front Option c:(R=Red, BBIack) 10-2528 Point ID DACT (Included with CyberCat 50 systems above) D.1.18.01 Peripheral Devices 10-2630 2 Button Expanded Protocol Remote Display P.1.103.01 10-2631 10 Button Expanded Protocol Remote Display P.1.107.01 10-2646 14 Button Expanded Protocol Remote Display P.1.108.01 -10-2373 Zone Annunciator 0.1.16.01 10-2627 Ethernet Module 0.1.22.01 10-2583 Multi-Interface Module P.1.85.01 Intelligent Sensors Photoelectric Smoke Sensor Non-Isolator Version 63-1052 P.1.88.01 63-1058 Photoelectric Smoke Sensor Isolator Version P.1.88.01 63-1053 Photo/Heat Combination Sensor Non-Isolator Version P.1.89.01 63-1059 Photo/Heat Combination Sensor Isolator Version P.1.89.01 60-1039 Thermal Sensor Non-Isolator Version P.1.90.01 60-1040 Thermal Sensor Isolator Version P.1.90.01 67-033 Ion Sensor Non-Isolator Version P.1.91.01 67-034 Ion Sensor Isolator Version P.1.91.01 63-1057 Duct Sensor Non-Isolator Version P.106.01 63-1062 Duct Sensor Isolator Version P.106.01 63-1056 Duct Housing P.106.01 Intelligent Sensor Bases 63-1054 6' Sensor Base Non-Isolator Version P.1.98.01 63-1060 6' Sensor Base Isolator Version P.1.98.01 63-1055 4' Sensor Base Non-Isolator Version P.1.99.01 63-1061 4" Sensor Base Isolator Version P.1.99.01 63-1064 Sounder Base P.101.01 63-1063 Relay Base P.101.01 Intelligent Modules 55-045 Mini-Monitor Module Non-Isolator Version P.1.93.01 55-050 Mini-Monitor Module Isolator Version P.1.93.01 55-041 4 Monitor Module Non-Isolator Version P.1.92.01 55-046 4" Monitor Module Isolator Version P.1.92.01 20-1063 Intelligent Pull Station Non-Isolator Version P.1.65.01 20-1064 Intelligent Pull Station Isolator Version P.1.65.01 55-042 Supervised Control Module Non-Isolator Version P.1.94.01 55-047 Supervised Control Module Isolator Version P.1.94.01- 10-2360 Series Solenoid Diode/Resistor (Needed for solenoids) 10-2413 Masterbox Interface 55-043 Relay Module Non-Isolator Version P.1.95.01 - 55-048 Relay Module Isolator Version P.1.95,01 Programming Parts 55-051 Infrared (I R) Remote Control Tool P.1.97.01 06-327 C-LINX Software 10-2629 1 Interface cable, USB/A Male to USB/B Male 10-2477 JDACT Programmer like Copyright© Fike Corporation All Rights Reserved. Form No, 0,11901-1 September, 2008 Specifications are suect to change without notice. Page 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FE ENGINEERING BUILDING MATERIALS LISTING PROG LISTING SERVICE LISTING No. 7170-0900:148 Page 1 of 2 CATEGORY: Control Unit (High-Rise) LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64024 Contact: Brent Mlika (816) 229-3405 x 1220 Fax (816) 229-5082 brent.mlika@fike.com DESIGN: Model CyberCat 1016 or 254 control unit, part no. 10-064-c-p-d orl0-066-c-p-d (C: R=Red or B=Black; p: 1=120V or 2=240V; d: B=Blank or L=Lexan)and Model Cybercat 50 Control Unit part no. 10-070-c-p(-d)(c: R = Red or B = Black; p: 1 = 120V or 2 = 240V; d: d = Dead Front, Blank = no Dead Front) fully addressable fire alarm control panels. Base configuration includes the main board, enclosure and a transformer. Models 1016, 254 and 50 are suitable for critical process management and voice evacuation via Fike Guard model FGX- MPJDP. Suitable for local, auxiliary, remote and central station services. Also suitable for proprietary PPU and proprietary receiving station when used with Model 10-2627 or 10-074. Refer to listee's data sheet for detailed product description and operational considerations. System components: 10-2472,-2525, 1016, 254 10-2620 50 Point Controller 10-2473 Supplemental Loop Module 10-2474 Supplemental Power Supply 10-2204 CRM4 Relay Module 10-2254 • Reverse Polarity Module 10-1832 Agent Releasing Module Ill 10-2482 Network Card FGX-MP/DP Voice Evacuation System 24-001 thru 24-012 Master Panel Voice Evacuation System 24-013 thru 24-024 Distribution Panel Voice Evacuation System 24-025 Fire Phone Jack S.G. Plate 24-026 Fire Phone Handset 24-027 Fire Phone Handset Cabinet 24-028 Fire Phone Station Surface Mount 24-038 Fire Phone Interface 24-039 Fire Phone Output 10-2483-C Cybercat 254 and 1016 Enclosure 10-2483-C-L Cybercat 254 and 1016 Enclosure with Lexan 10-2621-C Cybercat 50 EridosUre........................................................................... 10-2476 DACT 10-2321 Remote Display 10-11x LED Display Graphic 10-2413 Masterbox Supervision Module 10-2361 Series Impedence 10-2373 Zone Annunciator 55-052, -053 Releasing Module 55-042 Control Module *Rev. 06-27-08 bh 7170-0900:148 Page 2 of 2 FG-25, -25E, -50, -50E, FG-100, -100E, -150, -150E, FG-200, -200E 102630* 2631* -2646- 10-2583* 064* 102627* 074* 10-2624* Audio Adjunct Modules (CSFM # 6911-0900:145) Remote Display Multi-Interface Module Ethernet Module Fiber Optic Network Card RATING: INSTALLATION MARKING: APPROVAL: NOTE: 120 VAC/ 60 Hz or240VAC 50/60 Hz In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as a fire alarm control unit suitable for high rise application for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. This control unit meets the requirements of UL-864, 9th Edition Standards. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev. 06-27-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation "Z criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 17, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division DIMENSIONS Osc2igo twn V& Diflc110 n(Cqit ZCi ES 7-12 NoininI oltage V: 2 Notnina I C-apacity 20hour into t 0.36/ to 10.0V lOhour rate ( 0.72, to Sliour rate 1.22k ici j J •//h ic i ci iOV 3C (21.A to9.0V j 2.Th Vek1Iil :.9I I. b 2i /8 k&j.i Iteuil Rosistan';c• at 1KHz) 19 iri rvtEiuiuru [)19:lulrqo Cuirent icc 30 seconds: I.1IA fv1(iX(I1Jt$i1 0ischario Current icr S seconds: uporalrnq Teinpen aUrre Ra ngc lI(ii(Ji oc:3' 171 to 40 -T OOTTI [scharge 1 5C i5'l) to Storaie -1 5C(5i) to •.i(i'C. (IU'( CIiaro fletentien (sluIf lie) at 20C (G3"F) 1 month 02% 3 rncith S tnc'nth CIiarclinj r,lr.thcds at 15'C (7F) cyclo USC : CliarijIllq 1.' tag I4.I to 'I Maxilirtini Charging Current 2113, Slandiry use : l:Icl ci iii itjln(( Voltage 13.S0 to 11 Pi) V No curren 8 (mmli 10(111 renl Ufe expectancy: Cycle Use : 100% i:Joplh 01 cliscliarqe ?) i::yctes 805 depth of discinaugn 341 .ycles si::ix, del)(11 of discharge 550 cycles Standby Us-- yckirs Case Material AI3S (cut .11K & O.IV. c flanic miardant case) ••Ie:'iiiiiral hi R iiji':il:lc Sealed Lacl.Add atu: 'S. DESCRIPTION The Eclipse protocol, manufactured by System Sensor, is peer-to-peer, all digital ,•._ protocol from that allows for numerous applications such as fire, security, access and I ]VAC control. Eclipse series intelligent modules provides faster device - response time, with more flexibility than ever possible before. This digital, protocol enables pinpoint accuracy in as little as a quarter second - without interference problems that can plague other systems. I 1 The Eclipse system distributes intelligence to the networked devices. In fact; Eclipse turns every networked device into a peer, capable of generating messages readable by the entire system. Additionally, with Eclipse, no special communication cables are required, making it ideal for retrofit applications. The isolator versions have on-board short circuit isolators to prevent shorts on the signaling line circuit (SLC) from disabling all devices on the intelligent loop. Eclipse monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, vaterf1ow switches, and more. Each - module is rigorously designed and tested for electromagnetic compatibility and V environmental reliability, in many cases exceeding industry standards. Full sue modules mount in a standard 4" x 4" x 2 1/8" junction box. Wiring terminals al-c easily accessible for troubleshooting purposes. Relay modules arc to be designed for Uontlgurat!oli IN ibo! (55-0 activating products connected to an alarm system and the mini monitor module can monitor the wiring to the device for open circuits via an end of line resistor. 55-041/55-046 Monitor Modules are used to monitor the normally open contacts of an auxiliary device. In addition to monitoring the contact, the device will supervise the wiring to the device for open circuits .via an end of ]ine resistor. This device is capable of class A or class B operation. Also capable of short circuit detection. The small size of the 55-045/55-050 Mini Monitor Module allows it to fit inside devices or junction boxes behind devices. Also capable of short circuit detection. 55-042/55-047 Control Modules are used to switch an external power Supply or audio amplifier to notification appliances. The devices will supervise the wiring to the auxiliary device for open and short circuits via an end of line resistor. The control module will also have the capability to monitor the external power input for loss of power (DC voltage supplies only). This module is capable of Class A or Class B operation. 55-043/55-048 Relay Modules are designed for use in activation of products that are connected to an intelligent fire alarm system. It provides two sets of Form C contacts that switch together (one DPDT relay). There is also an input that is capable of monitoring a dry set of contacts for open or closed conditions. 55-052/55-053 Releasing Module ale designed to provide reliable operation of a solenoid or, Agent Release Module (ARM) for clean agent, carbon dioxide and pre-action sprinkler/deluge .systcm actuation. Each releasing module is protected from inadvertent operation by an intelligent switch, which requires transmission of a complex code before activating the releasing output. This module is capable of providing up to 20 amps Ca 24 VD( of output power for solenoid applications. The releasing module requires a separate 24 \'DC power source in addition to the SLC. 55-051 Configuration IR Tool is a remote control designed to communicate with F.elmpse devices via infrared IR signals. The remote control will give the user the ability to communicate with the panel and other devices through any selected device on the loop. The 55-051 can read device information such as type, loop, and address along with set loop, address, branch and service date. It can also initiate a walk test and a device test. The 55-051 features a 16-character liquid crystal display and a 17-button keypad. Form No. P.1.53.01-I 704 S. 10th Street . P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. . (816) 229-3405 (816) 229-0314 www.fike.com STANDARD FEATURES/SPECIFICATIONS Peer-to-Peer Communication Distributed intelligence * Greater system design freedom Digital communication protocol Numerous applications (Fire, Security, Access and ii VAC Control) * Fast response time Superior noise immunity Low standby current Mounts to standard 4" junction box Wiring terminals easily accessible Communicate with the devices via hand-held con figuration tool General Module Specifications Operating Voltage: 15-30VDC Alarm Current: 2.0 mA (red LED on) Temperature Range: 320 to 1200F. 00 to 49°C) Relative Humidity: 10% to 93%: non-condensing Dimensions: - 55-045/55-050: 2.7"W x 1.3"1-1 x 0.6"D - Others: 4.26"W x 4.2"H x 1.2"D Specifications: 55-042/55-047 Standby Current Avg.: 560 mA max. avg continuous broadcasts) External Power Supply: 9-80VDC (Normal Range); 0- ZV.DC (Trouble Range) End-of-Line Resistance: 39 k ohms (included) Maximum VAC Circuit Wiring Resistance: 100 Ohms Standby Current: 500 mA max. avg. (continuous broadcasts) Dry Contact Short Circuit Current: 30 mA max. avg. Relay Contact Ratings: - 3.6A @ 30VDC resistive non-coded - 2 A @ 30VDC resistive coded - 0.9 It @ 70.7VAC resistive non-coded - (.).7 A @ 70.7VAC inductive (PF=.35) non-coded Specifications: 55-051 Dimensions: 1.3"l-I x 2.2W x 7.7"L Communication Range: Up to 30 feet Battery Life: 168 hours (typical usage) Operating Temperature Range: 320 to 122°F Relative Humidity: 10% to 90% Ri-I non-condensing Specifications: 55-041/55-046 Standby Current: 485 mA max. (continuous broadcasts) IDC Voltage: 5.4VDC max. VMaximum IDC Wiring Resistance: 100 ohms Specifications: 55-045/55-050 Standby Current: - 485 mA max. (continuous broadcasts) - 745 mA max. continuous broadcasts IDC Shorted) IDC Voltage: 5.4VDC max. Wire Length: 6.5" Maximum IDC Wiring Resistance: 100 ohms AVAILABLE MODELS Description Fike Model No. Manf. Model No. Non-isolator Versions Monitor Module 55-041 EM-IM Relay Module 55-043 CY zpEM-IR Supervised Control Module 55-042 . EM-ISR Mini Monitor Module ........ Releasing Module . . . .55-045.........EM-IMM - 55-052 EM-1104 Isolator Versions Monitor Module 55-046 EM-IMI Relay Module 55-048 EM-IRI Supervised Control Module 55-047 EM-1SRI Mini Monitor Module 55-050 EM-IMMI Releasing Module 55-053 . EM-IRMI Accessories Control Module Barrier 20-1071 Surface Mount Box 20-1072 Configuration IR Tool 55-051 BA-CT — 10 I&" Copyright © Fike Corporation All Rights Reserved. COP P0 RATION Form No. P.1.53.01-1 July, 2005 Specifications are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGIINIEEIUNG - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0900:140 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64013 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 DESIGN: Models 55-042 and 557047 Supervised Control Module; Models 55-041 and 55046 Monitor Module; Models 55-043 and 55-048 Relay Module; 55-045 and 55-050 Mini- Monitor Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 73001653:180* 5Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 10, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Iiite//i,gsnt ,Manual Pu/I .Station APPROVALS UL - S2203 FM - 3020297 MEA - pending CSFM - 7150-0900:144 DESCRIPTION i.:. The Fike Intelligent Manual Pull Station, P/N 20..10i o state-of.the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for hike's intelligent CybetCat and Cheetah Xi fire alarm control panels. Because the 20-1063 is addressable, the control panel can display the exact location of the activated manual pull station. This leads fire service personnel quickly to the location of the alarm. FEATURES Aesthetically pleasing, highly visible, dual-action design. Meets ADA 5 lb. maximum pull force. Easily operated (dual-action). Attractive shape and textured finish. Mounts, semi-flush, to a standard single-gang (2.125" [5.398 cm] minimum depth), double-gang, or 4.0" (10.16 cm) square electrical box. When the handle latches in down position, the word "ACTIVATED" appears at the top of the handle in bright yellow to clearly indicate the station has been operated. Key/lock reset; needs only a 1/4-turn to lock/unlock. Includes Braille text on station handle. Captive screw terminals wire-ready for easy connection to SLC 1001) (accepts up to 12 AWG/3.1 mm2 wire). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Maintenance personnel can open station (for inspection and testing) without causing an alarm condition. Built-in multi color LED, which is visible through the handle of the station, flashes green in normal operation and latches on steady red when in alarm. ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a keyoperated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An ............................ . operated station shall automatically condition itself so as to he visually detected as activated. Manual stations shall be . . constructed of red-colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting or semi-flush mounting on a standard single-gang, double-gang, or 4.0" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on command from the control panel, send data to the panel. representing the state of the manual switch. Manual stations shall provide address setting by use of IR Tool. Form No. P.1.65.01-3 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. (816) 229-3405 . (816) 229-4615 www.fike.com ELECTRICAL SPECIFICATIONS Normal Operating Voltage: 24VDC. Standby Current: 370 pA. max. Average (continuous broadcasts) Maximum Alarm Current: 2 mA (red Led on) Temperature Range: 32°F - 120°F (0°C -- 49°C). Relative 1-Tumidity Range: lO% - 93% non-condensing. Maximum SLC loop voltage: 28.0 VDC. INSTALLATION The 20-1063 can be semi-flush mounted into a singlegang, double-gang, or standard 4.0" (10.16 cm) square electrical outlet box, or surface mounted. CONSTRUCTION Shell, door, and handle are molded of durable IJEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI\TATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automatically resets the switch. Manual stations connect with two wires to one of the control panel SLC loops. Each manual station, on command from the control panel, sends data to the panel representing the state of the pull station switch. IR tool allows address setting (01-254). PRODUCT LINE INFORMATION 20-1063 Dual-action addressable pull station Includes key lock/reset feature. :1 .• -- '_ ,'. -.i• i , .1 V l ;3 - : - . _____________________________________ I •-i• '. - I . LOOP -- - - - - ........................ ............ ....................... --------------------------------.------------- LED iFikoCopyright Fike Corporation All Rights Reserved. -- Form No. P.1.65.01-3 July, 2008 Specifications are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 3 4 LISTING No. 7150-0900:144 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs, MO 64015 Contact: Brent Mlika (816) 229-3405 ext. 1220 FAX (816) 229-5082 alp DESIGN: Models 20-1063 and 20-1064, *20..1343 and *201344 fire alarm pull boxes. Units are dual action pull stations that have normally open switch contacts, key lock, utilizes addressable module. Refer to listee's data sheet for detailed product description and operational considerations. RATINGS: *24 V dc, 300 pA INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, and UL label. APPROVAL: Listed as fire alarm pull boxes, for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Formerly 7150-1653:184 REV 04-02-07 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 10, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division INTELLIGENT LOW PROFILE PLUG-IN DETECTORS DESCRIPTION The Eclipse series intelligent low profile Plug-in detectors manufactured by System Sensor, is a peer to peci all .digital protocol that. allows for numerous applications such as fire secuuty, access and 1-IVAC control ..Eclipse provides faster deuce response time with more fleibilit3 than ever possible before This digital, peer to peer protocol enables pinpoint accuracy in as little as a quarter second without interference problems that can plague other s3stems The Eclipse s)stern distiihutes iritdiligence to the networked deuces In fact Eclipse turns every networked device into 's peer, capable of generating messages readable b3 the entire s3stcm Additional!3 with I clips-,.no special communication cables are required making it ideal for retrofit applications 63-1052 in 63-1054 Base The isolator versions have on board short circuit isolators to prevent shorts on the from disabling devices the intelligent loop signaling line circuit (SL() all on 6371.052/63-1058 Photoelectric Smoke Sensor Photoelectric provides peer- to-peer digital protocol for reliable, fast communications The scnsor includes a tn color LED for instant indication of device status An AcclirnsreTM feature ol is defaulted ON to provide optimum fire detection response This feature 'illows sensors to respond to a particular environment and its operating parameters ire maintained within non-volatile ol'rtik RAM in the sensor. Dual Alarms (night and day sensitivity) with threshold settin,s betssecn 1.3 7 3 6%ft Dual Pie Alarms with threshold setting between 0.5 4 O%ft 604039 in 63-1055 Base 63-1053/63-1059 Photo/Heat Combination Sensor provides peer-to-peer digital protocol .for reliable fast communications The sensoi has the ability to ahim from either or both different types of detection and includes a tn coloi I ED for instant indication of deuce status Dual electronic thermistors acid 135° F fixed temperature thermal sensing to the standard photoelectronic sensor. Esen though this is a dual sensing device it only uses one address on the SLC loop 60-1039/60-1040 Thermal Sensor are. spot type heat detectors designed to be for 'r setpoint range of 135° to 174°F for ordinary detection or programmable 175° to 190°F for intermediate detection Detectors in the ordinary range maybe programmed for either fixed or 15°F rate of rise operation Additional, features include Flame Inhancement and Pre -alarms: from 700 150°F 63-1053 in 63-1060 Base 67-033/67-04 Ion Sensors pros ide peer to peer digitil protocol for relisbie fist corn muni cations. The sensor includes a triLcolor LLD for instant indication of deuce status. An Acclimate feature is defaulted ON to provide optimum fire settings detection response Dual alarms (day and night sensitivity) with threshold 1115 between 80-50 MIC are available Dual pre ahrms with threshold settings between 100-40 MTC are 'ilso available. Configurable for Acclimate alarm strficauon and drift compensation 55-051 Configuration JR Tool is designed to communicate with Eclipse devices vi'i infrared signals The configuration tool will give the user the ability to communicate with the panel and other devices through any selected device on the loop. The 67-033 In 63-1060 Bose 55-051 can read device information such as type, loop, address and sensitivity along with set loop, address, branch and service date. it can also initiate a walk test. The 55-051 features a 16-character liquid crystal display and 17-button keypad. Form No. P.1.52.01-4 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. . (816) 229-3405 (816) 229-4615 www.fike.com STANDARD FEATURES/SPECIFICATIONS Sleek, low-profile design Distributed intelligence Greater system design freedom Peer-to-peer communication * Digital communication protocol Numerous applications (Fire, Security, Access and 11 VAC control) Fast response time Superior noise immunity Low standby current c;ommiimcate with the devices via hand- held configuration tool Height: 2.1" (51 mm) Diameter: 6.1" (155 mni, installed in 63-1054/63-1060 base; 4.1" (104 mm), installed 63-1055/63-1061 base Shipping Weight: - Heat: 4.8 ox. (136 g) - Photo/Photo with Heat: 5.2 ox. (147 Operating Temperature Range: - Photo: 320 to 120°F (00 to 490C) - Photo with Thermal: 32° to 100°F (00 to 38°C) - Thermal: —4° to 100°F (-200 to 38°C); 1350. to 1740F setpoint - High Temperature Thermal: _40 to 15001:: (200 to 660C); 1750 to 190°F setpoint Spacing for Thermal Detectors: - Detectors set between 1350 to 1550F or 1750 to 190°F : 50 foot spacing - Detectors set between 156' to 174°F: 15 foot spacing o Relative I--lumiditv: 0% to 93% Ri-I non-condensing Thermal Ratings: - Default Temperature Setpoint: 135°F (57°C) - Rate of Rise Detection: 15°F/mm. (8.3°C/mm.) - Maximum Temperature Heat: 190°F (88°C) Voltage Range: 15— 30 volts DC peak Standby Current (max. avg.): - Thermal: 215 1iA @24 VDC (continuous broadcasts) - Photo/Photo with Thermal: 481 pA @ 24 VDC (continuous broadcasts) 55-051 Specifications Dimensions: 1.3"Ii x 2.2"W x 7.7"L Communication Range: Up to 30 feet Battery Life: 168 hours (typical usage) Operating Tempeiature Range: 320 to 1220F (00 to 50°C) Relative Humidity: 10% to 90% RH non-condensing AIAII ARt MflflPI S Fike PIN Manf. Model No Description 631052I631058* Photoelectric Smoke Detector 631053/631059* Photoelectric with Thermal 601039I601040* Fixed Temperature/ROR/Hi-Temp Thermal Detector 67033I67034* Ion Sensor Mounting Bases 631054I631060* 6" Flanged Mounting Base 631055/631061* 4" Flangeless Mounting Base 02-10373 RMK400 Recessed Mounting Kit 20-1083 SMK400E . 4" Flangeless Surface Mounting Kit 20-1084 AIO-29-400 6" Flanged Surface Mounting Kit Base 63-1064 63-1063.....- .Relay Sounder Base Accessories 20-1085 F110 Retrofit Flange 02-3868 RA400Z Remote LED Annunciator 20-1087 XR213 Detector Removal Tool (20-1089 included) 02-4986 XP-4 Extension for 02-4985 (5-15 ft) 20-1089 T55-127-000 Detector Removal Head 20-1090 BCK-200B Black Detector Kit 55-051 Configuration lR Tool * Indicates models with bin/I in isolators. Copyright © Fike Corporation All Rights Reserved. Form No. P.1.52.01-4 August, 2008 Speciflcations are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE M LISTING No. 7272-0900:139 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64013 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 DESIGN: Models 63-101O58, 63-1057, 63-1062, 63-1053 and 63-1059 photoelectric smoke detectors. Models 63-1053 and 63-1059 employ a 135° fixed temperature electronic thermistor heat sensor for use only as a supplement to the smoke detector. This thermal circuitry is not approved for use in lieu of required heat detectors. Models 63-1052, -1058, -1053, -1059 are suitable for installation in a duct, velocity range 500-4000 fpm and open area protection, velocity range 0-4000 fpm. Models 63-1057 and 63-1062 are suitable for installation inside 63-1056 duct housing only. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 72721653:181* *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 10, 2008 Listing Expires June 30. 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 11 LISTING No 7270-0900:141 Page 1 of 1 CATEGORY: Heat Detector LISTEE: DESIGN RATING INSTALLATION MARKING APPROVAL XLF Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64013 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 ' 4 011 Models 60-1039 and 60-1040 combination fixed-temperature and rate-of-rise type heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. 21.6 V Fixed Temperature Rating: 135- 155°F at 50 ft spacing 165-174°F atl5ftspacing 175-190°F at 50 ft spacing In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical/temperature rating, and UL label. Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7270-1653:179 *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 10, 2008 Listing Expires June 30. 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0900:138 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64013 Contact: Brent Mlika (816) 2293405 X 1220 FAX (816) 229-5082 DESIGN: Models 6 -1054,63-l055, 63-1060, and 63-1061 detector bases. Each unit consists of resistors, capacitors, diodes, photo diodes and LED, mounted on a printed wiring board inside an enclosure which has an opening to the outside air. These devices are intended for installation on a vertical wall surface, ceiling or in a duct with a UL Listed Head. Refer to the listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible 63 Series smoke or heat detector heads and fire alarm control panels. Refer to listee's Installation Instruction Manual for details. XLF: 7300-1653:178* *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 10, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Technical Data Sheet las, L N NXI Fire Alarm Cables 2833 West Chestnut Street all Washington, PA 15301 Toll Free: (800) 245-4964 Fax: (724) 222-6420 www.westnenn-wpw.corn as ,ass,asssaaaasasaassaassl S se PART NUMBER: 994 DESCRIPTION: 14/2 Solid bare copper conductors, unshielded with an overall jacket. NEC RATING: FPLR, NEC Article 760 APPROVALS: (UL) or (ETL)us Listed APPLICATION: Indoor for (Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits) asss assussasassSsSuserssssuszsssasaasasasasss2srssasasssss-sassus Construction Parameters: Conductor 14 AWG Bare Copper Stranding Solid Insulation Material PVC Insulation Thickness 0.012" Nom. Number of Conductors 2 Shield None Drain None Jacket Material . PVC Jacket Thickness 0.0 15" Nom. Overall Cable Diameter 0.195" Nom. Approximate Cable Weight 41 Lbs/1M' Nom. Flame Rating UL 1666 Riser Flame Test Electrical & Environmental Properties: Temperature Rating -20deg C to 60deg C Operating Voltage 300 V RMS Max.Capacitance Between Conductors @ 1 KHz 32 pf/ft Nom. DC Resistance per Conductor @ 20deg C 2.43 Ohms/1M' Nom. Insulation Colors Black, Red Jacket Color Red, Black, Blue, White, Yellow RoHS Compliant Yes naasss esassasas " ssss,sasasass 555555 ass ass u as. Sn sasnassasas -sasmssasssassnssnr--r -sr- snssr- - Mechanical Properties: Max. Recommended Pull Tension 99.4 lbs. Mm. Bend Radius (Install) 2" Specification Issue Date: 7/06 This document is the property of West Penn Wire. The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire Standard Lengths are l000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY LISTEE DESIGN: INSTALLATION MARKING APPROVAL 7161-0859:101 Page 1 of 1 Cables-Fire Protective Signaling 4010 West Penn Wire, P0 Box 762, Washington PA 15301 Contact: Diane Kelley (724) 222-7060 FAX (724) 2291151* Types FPL and FPLP power limited fire protective signaling cable. Refer to listees data sheet for detailed product description and operational considerations. In accordance with listees printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, type, NEC rating and UL label. Listed as power-limited fire protective signaling cable. *Rev. 05-23-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or fr recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date issued: MAY 1 9, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Technical Data Sheet WMANNIRE Fire Alarm Cables .-.--. . . 2833 West Chestnut Street Washington, PA 15301 Toll Free: (800) 245-4964 - Fax: (724) 222-6420 www.westpenn-wpw.cOrn - C PART NUMBER: 990 DESCRIPTION: 16/2 Solid bare copper conductors, unshielded with an overall jacket. NEC RATING: FPLR, NEC Article 760 APPROVALS: (UL) or (ETL)us Listed APPLICATION: Indoor for (Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits) .................................... Construction Parameters: Conductor Stranding Insulation Material Insulation Thickness Number of Conductors Shield Drain Jacket Material Jacket Thickness Overall Cable Diameter Approximate Cable Weight Flame Rating Electrical & Environmental Properties: Temperature Rating Operating Voltage Max.Capacitance Between Conductors @ 1 KHz DC Resistance per Conductor @ 20deg C Insulation Colors Jacket Color RoHS Compliant Mechanical Properties: Max. Recommended Pull Tension Mm. Bend Radius (Install) 16 AWG Bare Copper Solid PVC 0.010" Nom. 2 None None PVC 0.015" Nom. 0.155" Nom. 25 Lbs/1M' Nom. UL 1666 Riser Flame Test ssam na s -20deg C to 60deg C 300 VRMS 32 pf/fi Nom. 3.85 Ohms/IM'Nom. Black, Red Red Yes 62.4 lbs. 1.75" Specification Issue Date: 7/06 This document is the property of West Penn Wire. The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire Standard Lengths are 100011. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. I Technical Data Sheet Aquaseal ® Fire-Alarm Cables --- PART NUMBER: AQ225 WPtNN WIRE 2833 West Chestnut Street A.1 Washington, PA 15301 Toll Free: (800) 245-4964 Fax: (724) 222-6420 www.westpenn-wpw.COm wal —c:r -- -- - -- DESCRIPTION: 16/2 Stranded bare copper conductors, overall unshielded with Aquaseal tape and overall jacket. NEC RATING: FPL - PLTC, NEC Article 760 And 725 APPROVALS: (UL) or (ETL)us Listed —Direct Burial APPLICATION: Materials suitable for outdoor use (direct burial), and indoor trays, allows a variety of uses for (Low voltage industrial process control circuits, Power-Limited circuits, Power-Limited fire alarm circuits, Power-Limited tray cable PLTC) Construction Parameters: Conductor Stranding. Insulation Material Insulation Thickness Number of Conductors Shield Drain Water-Blocking Tape Jacket Material Jacket Thickness Overall Cable Diameter Approximate Cable Weight Flame Rating Electrical & Environmental Properties: Temperature Rating Operating Voltage Max.Capacitance Between Conductors @ 1 KHz DC Resistance per Conductor @ 20deg C Insulation Colors Jacket Color RoHS Compliant T1A455-82B Water Infiltration Test Compliant UL 444 & 13 Compliant Mechanical Properties: Max. Recommended Pull Tension Mm. Bend Radius (Install) 16 AWG Bare Copper 7x24 PVC with Nylon PVC 0.015" Nom. Nylon .005" Nom. 2 (1 Pair) None None 2 Ply water swellable tape Sunlight/ Moisture Resistant PVC 0.040' Nom. 0.295" Nom. 48 Lbs/lM' Nom. UL 1685 Vertical Tray -20deg C to 60deg C 300 V RMS 28 pf/ft Nom. 4.2 Ohms/lM' Nom. Black, Red Black Yes Yes 54 lbs. 2.9" Specification Issue Date: 7/06 This document is the property of West Penn Wire. The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire Standard Lengths are 100011. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.