Loading...
HomeMy WebLinkAbout3207 GREY HAWK CT; ; FA070046; Permit1/17/25, 3:22 PM FA070046 Permit Data City of Carlsbad Fire Alarm Permit 3207 GREY HAWK Job Address: CT Permit Type: FALARM Parcel No: 2210150100 Lot #: 0 Reference No.: Permit No: FA070046 Status: ISSUED Applied 5/9/2007 Approved: 5/17/2007 Issued: 5/17/2007 PC #: Inspector. Project Title: PALOMAR CONCOURSE ONE TI FIRE ALARM PLAN CHECK & INSPECTION Applicant: STANDARD ELECTRONICS STEA 2830 VIA ORANGE WAY SPRING VALLEY CA 619-670-2332 Owner: CONCOURSE ONE LLC 5330 CARROLL CANYON RD #200 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 117 0 117 0 about:blank 1/1 SUBMITTAL DATA 4/23/2007 Sta=ndard April 23, 2007 Electronics 9340 Stevens Rd. Santee, CA 92071 Ph# 619-596-9950 Fax# 619-596-8850 SUBMITTAL SHEET PROJECT: PALOMAR CONCOURSE SUITE 150, 3207 GREYHAWK CT. CARLSBAD, CA 92008 CONTR: BILBRO CONSTRUCTION CO., 8954 SAN DIEGO DR., SUITE 102, SAN DIEGO, CA 92108 EQUIPMENT FIRE NO SECTION ITEM QTY DESCRIPTION MODEL NO. DATA SHEET ADDRESSABLE MONITOR MODULE 1 5 AMM-2F FCI SFM #7300-0694:178 REMOTE TEST STATION SYSTEM 2 5 RTS451 SFM 7300-1653:110 SENSOR 16 AWG/ 2 CONDUCTOR - SOLID CONDUCTORS POWER LIMITED - RED OVERALL JACKETED - FIRE 3 A/R 990 WEST PENN PROTECTIVE SIGNALING CABLE SFM #7161-0859:101 18 AWG/ 4 CONDUCTOR - SOLID CONDUCTORS POWER LIMITED - OVERALL JACKETED - FIRE PROTECTIVE 4 A/R 982 WEST PENN SIGNALING CABLE SFM #7161-0859:101 FIRE CONTROL LEI INSTRUMENTS by Honeywell Description The FCI VelocitiTM Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit (IDC) with a 471V end-of-line resistor. This mod- ule provides an address for any device or group of de- vices connected to this circuit on the signaling line circuit (SLC) of the FCI addressable series fire alarm control panel. Any initiating device with normally open (NO.) dry contacts may be made addressable when connected to the AMM-2F module. The VelocitilM Series use a communication protocol that substantially increases the speed of communication be- tween the sensors and certain FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier de- signs. The AMM-2F module can be programmed to provide a wide variety of input functions to the FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, plenum detector, water- flow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even pos- sible to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Ordering Information Model Description AMM-2F Addressable monitor module, single circuit Style B, Class B Velociti" and E3 Series' are trademarks of Fire Control Instruments. Velocill'"m Series AMM-2F Addressable Monitor Module . ---- . ! '• '•" -I.- AMM-2F Features Compact size allows easy installation. Class B, Style B, initiating circuit 40 Ohm line resistance for each initiating device circuit Connects to any normally open dry contact device. Bicolor LEDs flash green whenever the module is addressed, and light steady red on alarm.* *Note: Only the red LED is operative in panels that do not oper- ate in VelocitlTm mode. Specifications An ISO 9001-2000 Company SIGNALING ®<>MEA LISTED APPROVEC Approvec t1941 3023594 2210 EVollV 01300 069 118 Supervisory current: Alarm current: Operating temperature: Relative humidity: End-of-line Resistance: Dimensions: 0.0004 amp. 0.0006 amp. 32" to 120" F (0" to 49" C) 10 to 93% (non-condensing) 47K ohms 1.3" Lx2.5"Wx0.5" D (3.3x5.5x 1.3 cm) FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Fire Control Instruments for their use. @2005 Fire Control Instruments. All nghts reserved. www.flrecontrolinstruments.com 9020-0626 Rev. A page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0694:178 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fire Control Instruments, 16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 19 DESIGN: Models AMM-4, *AMM4F AMM-2 and *AMM.2 monitor modules and Models AOM, AOM- 2, AOM-2R, *AOM..2RF AOM-2S and *AOM..2SF control modules. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules XLF: 7300-1653:103 El Rev 09-07-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Models Available BEAM1224 4 wire conventional beam smoke detector with 8 reflector BEAM1224S 4 wire conventional beam smoke detector with 8 reflector and integral sensitivity test Accessories BEAMLRK Long range accessory kit (3) additional reflectors (Required for applications in excess of 230 ft. [70m]) B EAM MM K B EA M SM K RTS45I. RTS451KEY BEAM H K B EAM H KR Multi-mount kit (Provides ceiling or wall mount capability with increased angular adjustment for either the beam or the reflector. When installed with the transmitter/receiver unit, BEAMSMK must be used as well) Surface mount kit Remote test station used to initiate the NFPA sensitivity test function Remote test station with key lock Heater kit for transmitter/receiver unit (See electrical requirements on back) Heater kit for reflector (See electrical requirements on back) S Product Overview 16 to 328 foot protection range Single-ended, reflective design User friendly alignment procedure 6 user selectable sensitivity levels Optional integral NFPA 72 sensitivity test feature Removable plug-in terminal blocks Digital display for easy alignment Built-In automatic gain control compensates for signal deterioration from dust build-up Remote test station optional Paintable cover Easiest alignment in the industry ( DR <jF~M> MEAMSFM LISTED —Rom approved approved $911 3017888 72601.209.228 5444-0 2165 System Sensor Model BEAM1224 is a 4-wire conventional projected beam smoke detector. It is uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. It is to be used with UL Listed compatible control panels only. Installation of the single-ended reflective design is much easier than the dual-ended projected beam detectors. Alignment is quickly accomplished via an optical sight and a 2-digit signal strength meter incor- porated into the product. Listed for operation from —22°F to 1310F, BEAM1224 can be used in open area applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detection. BEAM1224 consists of a transmitter/receiver unit and a reflector. When smoke enters the area between the unit and the reflector it causes a reduction in the signal and, when the smoke level reaches the predetermined threshold, an alarm is activated. BEAM1224 has four standard sensitivity selections along with two Acclimate set- tings. When either of the two Acclimate settings are selected the detector will auto- matically adjust its sensitivity using advanced software algorithms to select the opti- mum sensitivity for the specific environment. BEAM1224S is equipped with an integral sensitivity test feature that consists of a test filter attached to a servo motor inside the detector optics. Using the remote test station RTS451, the motor is activated and moves the filter in the pathway of the light beam, thereby testing detector sensitivity. This integral sensitivity test feature allows the user to quickly and easily meet the annual maintenance and test require- ments of NFPA 72. OPTICAL GUNSIGHT ALiGNM CGNALENT - 0 STRENGTH METER HORIZONTAL OP1TCS ALIGNMENT KNOB .AUGNMENT TEST VERTICAL OPTICS KNOB ALIGNMENT - - RESET CO27t-01 Activated Test Feature (BEAM1224S only) BEAMMMK (detector and surface nit Operational Specifications Protection Range 16 ft. to 328 ft. (5m to lOOm) Adjustment Angle +/— 10 Degrees horizontal & vertical (The optics move independent of the unit) Sensitivity Levels Level 1 — 25% Level 2 — 30% Level 3 — 40% Level 4 — 50% Acclimate Level 1 — 30-50% Acclimate Level 2 — 40-50% Fault Condition (Trouble) 96% or more obscuration blockage In alignment mode Improper initial alignment Self-compensation limit reached Alignment Aid Optical gunsight Integral signal strength indication 2-digit display Alarm Indicator Local red LED and remote alarm Trouble Indicator Local yellow LED and remote trouble Normal Indicator Local flashing green LED Test/Reset Features Integral Sensitivity Test Filter (BEAMI224S only) Sensitivity filter (Incremental scale on reflector) Local alarm test switch Local alarm reset switch Remote test and reset Switch (Compatible with RTS45I and RTS451KEY test station) Smoke Detector Spacing On Smooth ceilings, 30-60 feet between projected beams and not more than one-half that spacing between a projected beam and a sidewall. Other spacing may be used depending on ceiling height, System Sensor Sales and Service airflow characteristics, and response requirements. See NFPA 72. Environmental Specifications Temperature —22°F to 131°F (-30°C to 55°C) Humidity 10-93% RH Noncondensing Electrical Specifications Voltage 10.2 to 32 VDC (BEAM1224) 15 to 32 VDC (BEAM1224S) BEAMI224S should not be used with 12V power sources AVG. Standby Current (24VDC) 17mA Max AVG. Current During Testing 500mA Max AVG. Alarm Current (24VDC) 38.5mA Max AVG. Fault Current (24VDC) 8.5mA Max AVG. Alignment Mode Current (24VDC) 28mA Max Mechanical Specifications Detector Dimensions 10"H x 7.5"W x 3.3"D (254mmH x 191mmW x 84mmD) Reflector Dimensions (16' to 230') 7.9" x 9.1" (200 x 230mm) Reflector Dimensions for (beyond 230') 15.7" x 18.1" (400 x 460mm) Electrical Specifications (BEAMHKR) Voltage 15 to 32V Current 450mA Max at 32V (per reflector) Power Consumption (Per reflector) 7.7W @ 24V; 15W @ 32V Electrical Specifications (BEAMHK) Voltage 15 to 32V Current 92mA at 32V Power Consumption 1.6W @ 24V; 3W @ 32V System Sensor Headquarters System Sensor Canada System Sensor in Chins System Sensor - Far East system Sensor - India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5119 Fx: 85.22.736.6580 Fx: 91.124.237.3118 Ph: 800/5EN50R2 System Sensor Europe System Sensor in Singapore System Sensor - Australia System Sensor - Russia Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 0 2005 System Sensor. The company reserves the right to change product specifications without notice. A05.0365.002.2/05.#1397 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:110 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Lin (630) 377-6580 ext. 1185 FAX (630) 377-7245 AN JV DESIGN: Models RTS45I and R1S451 KEY remote test switches, and Model RTC remote test station kit. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as accessory devices for use with separately listed compatible duct smoke detectors. NOTE: Formerly 7300-0087:129, 7300-1209:129 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Temperature range: -20° (to 75° C dry locations Meets 300 volt requirements as specified in Section 760 of the NEC APPLICATIONS Indoor (non-conduit per NEC) for: Audio circuits itrol circuits iiing circuits Notification circuits SPECIAL NOTES Select cables are available in outdoor and direct burial versions. See Aquaseol® product line for details Orange ripcord under jacket Catalog No. 980, 982, and 990 are also available with a Blue, Green, White or Yellow jacket o UL listed NEC type FPLR __________________________________________ AWG Size & Nom. Insulation (atolog No. of Strandin Thickness Norn. Thickness Jacket Norn. O.D. D.C.R.==now= 1084 ' 6 22 Solid .010 .25 .020 .51 i.179 4.55 17.5 1086 8 22 Solid .010 .25 .020 .51 .193 4.90. 17.5 filM 980 1 18 Solid .010 .25 .020 .51 .156 3.96. Pair 6.5 Q/M 982 4 18 Solid .010 .25 .020 .51 .188 4.78 6.5WM' 984 6 18 Solid 010 25 020 51 224 569 6.5 92/M' 986 8 18 Solid .010 .25 .020 731 .252 6.40 988 .10 18 Solid .010 .25 .020 .51 .294 7.47, 6.5!0/M' 990 1 16 Solid .010 .25 .020 .51 .165 4.19 Pair 4.1Q/M' 992 4 16 Solid .010 .25 .020 .51 .213 5.41 4.1 WM' 994 1 14 Solid .012 .30 .025 .64 .205 5.21 Pair 2.6 WM' 998 1 12 Solid .012 .30 .025 .64 .235 5.97 Pair 1.8c2/M ' Standard spool size 1000 feet I COLOR CODE Refer to page 51 JACKET: Red 50 -1I -WEST PENN WIRE /CDT ower-Limited Multiple Conductor/unshielded DESCRIPTION ASTM bare copper PVC insulation • Twisted pair or cabled construction • PVC fillers as required IlJL • Polyester binders as required • Overall 75° (PVC jacket RATING Constructed in accordance with UL Standard 1424 Complies with UL 1666 Vertical Shaft (riser) Flame Test V CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-0859:101 Page 1 of 1 CATEGORY: Cables-Fire Protective Signaling LISTEE: West Penn Wire, P0 Box 762, Washington PA 15301 Diane Kelley (724) 222-7060 FAX (724) 2291151* DESIGN: Types FPL and FPLP power limited fire protective signaling cable. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type, NEC rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. Rev. 05-23-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 14, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager