HomeMy WebLinkAbout3125 LIONSHEAD AVE; ; FPC2024-0020; PermitPERMIT REPORT C7city of Carlsbad Print Date: 09/23/2024 Permit No: FPC2024-0020 Job Address: 3125 LIONSHEAD AVE, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel : 2218800100 Track #: Applied: 02/08/2024 Valuation: $1,040,920.76 Lot #: Issued: 03/07/2024 Occupancy Group: Project #: Finaled Close Out: 09/23/2024 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Robinson, Jarrod Plan Check 4*: Valdes, Rebecca Cheung, Nathaniel Project Title: Description: RACEWAY INDUSTRIAL (UPS) -REVISION OF DIGITAL SUBMITTAL FOR FIRE ALARM INSTALLATION (183 DEVICES, ADDRESSABLI (REV 1: ADDING 12 MODULES) Applicant: FPContractor: CHULA VISTA ALARM INC CHULA VISTA ALARM INC JAMES RODRIGUEZ 6175 PROGRESSIVE AVE, 4* STE 400 1105 CLOUDWALK CANYON DR SAN DIEGO, CA 92154-6649 CHULA VISTA, CA 91911-6835 (619) 585-9111 (619) 585-9111 FEE AMOUNT FIRE Hourly Services (each additional hour) $170.00 FIRE Hourly Services (first hour) $200.00 FIRE Plan Review (per hr - Regular Office Hours) $170.00 FIRE TI Fire Alarm System $781.00 Total Fees: $1,321.00 Total Payments To Date: $1,321.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov PROJECT: Raceway Industrial Tenant Improvement - UPS 3125 Lionshead Avenue Carlsbad, CA 92008 SYSTEM: FIRE ALARM SYSTEM EXPANSION FOR THE TENANT IMPROVEMENT SUBMITTED BY: CVA Security 6175 Progressive Avenue Suite 400 San Diego, CA 92154 PHONE: (619) 585-9111 DATE SUBMITTED: February 7, 2024 Potter IPA-100 Fire Alarm System Equipment NEW EQUIPMENT LIST Model # Description Mfg. CSFM# IPA-100 Fire Alarm Control Panel Potter 7165-0328:0500 UD-2000 DACT Module Potter 7300-0328:0515 PSN-1000 NAC Extender Power Supply Potter 7165-0328:0195 PAD3 00-PD Photoelectric Smoke Potter 7272-0328:0541 Detector PAD300-6DB Smoke Detector Base Potter 7300-0328:0539 PAD 100-OROI Input/Output Module Potter 7165-0328:0500 PADIOO-RM Addressable Relay Module Potter 7165-0328:0500 PAD100-DRTS Remote Indicator Test Switch Potter 7165-0328:0500 SCRL Ceiling Strobe System Sensor 7125-1653:0504 Multi-Candela PC2RL Ceiling Horn Strobe System Sensor 7135-1653:0503 Multi-Candela Central Station UL Certificate of Compliance (2.)POTTER (IPA-100) The Symbol of Protection (Fire Alarm Control ParcM Features 127 addresses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class A or Class B for SLC, P-Link and NACs 5 Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at I Amp each, ideal for manual release and abort Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event History Buffer Cabinet will house up to 18 AH batteries Optional two line DACT with UD-2000 that can report General, Zone or Point Information Built in [P Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information NYC Fire Dept. !: Product includes 5 year warranty Certificate of Approval UUKL Listed for Smoke Control 6266 APPROVED LISTED Description The IPA-100 is an analog/addressable releasing fire alarm system with a total system capacity of 127 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The IPA-100 has a Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at I Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The 1/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA-100 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-l000 may be used to extend releasing capability. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1 000 adds another 10 Amps of power, 2 additional input circuits and the IPA-100 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- l000E has space to allow the installation of up to six loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Technical Specifications Dimensions 16"W x 17"I-1 x 3 Q'D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 20 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA 5 Amps power for NACs, I/O, and P-Link Battery 3 Amps per NAC, regulated - I Amp per I/O circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of I Amp Temperature and 32° to 1200 (0°C to 49°C) with a maximum Humidity Range humidity of 93% non-condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 92, 750, and 2001 ANSI/UL 864 - Local (L), Remote Station (RS), Central Station (CS), Propriety (PPU). Auxiliary (AUX).Type of Service: Standards Automatic (A), Manual (M), Water flow (WE) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC). Reverse Polarity (Rev Pol), Other Technologies (OT) IBC (International Building Code) Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101- REV 3 • 5/23 PAGE I OF 5 (E.)POTTER (i PA-I O& The Symbol of Protection Fire SLC Loop Accessories The control panel may be connected with up to 127 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD Series-PD Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.1 to 3.50/./foot. UL 268 7th Edition. Combination Analog Photoelectric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.1 to 3.5 '/O/foot PAD Series-PHD obscuration and a fixed temperature range of 135° to 185° F heat detector. Smoke detection compliant with UL 268 7th Edition. Combination Photoelectric Smoke/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Carbon PAD Series-PCD Monoxide detection compliant with UL 2075. Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Heat PAD200-PCHD detection with a fixed temperature range of 1350 to 185° F and UL 521 7th Edition compliant. Carbon Monoxide detection compliant with UL 2075. PAD Series-RD Analog Fixed Temperature (135° - 185°F) or Rate-of-Rise Heat Detector (software selectable). PAD Series-DUCTR Addressable Duct Smoke Detector with Form C Relay rate at lOAmps @ 250/120VAC or 8 Amps at 30VDC. PAD Series-DUCT Addressable Duct Smoke Detector. PAD 100-6DB 6" round base that is mountable to an electrical box and wired for connection to the PAD 100/200 devices. PAD 100-4DB 4" round base that may be mounted to an electrical box and wired for connection to the PAD 100/200 devices. Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop and used for PAD 100-LB connection to the PAD 100/200 devices. PAD 100- RB Addressable Relay Base that contains one relay controlled by the SLC. Relay at rated at 2 amps at 30 VDC or 0.5A at 125VAC. For PAD 100/200 devices only. Addressable Sounder Base that contains an addressable sounder module which allows for configuration of local, group, and/ PAD 00- SB or all call. For PAD 100/200 devices only. PAD Series-CD Addressable CO gas detector. PAD200-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. PAD300-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure or pendant mount applications. Addressable Low Frequency Sounder Base that contains an addressable sounder module which allows for configuration PAD loo-LFSB of local, group, and/or all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) and used for connection to the PAD 100/200 devices. Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W and PAD IOOSPKB used for connection with the PAD 100/200 devices. PAD300-6DB 6" round base which is mountable to an electrical box and wired for connection to the PAD300 devices. PAD300-4DB 4" round base which is mountable to an electrical box and wired for connection to the to the PAD300 devices. Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. Used for PAD300-1B connection to the PAD300 devices. Addressable Relay Base that contains one relay controlled by the SLC. The Relay is rated 2 amps at 30 VDC or 0.5A at PAD300 RB 125 VAC and used for connection to the PAD300 devices Addressable Sounder Base that contains an addressable sounder module which allows for configuration of local, group, and/or PAD300 - SB all call; and used for connection to the PAD300 devices. Addressable Low Frequency Sounder Base that contains an addressable sounder module which allows for configuration PAD300-LFSB of local, group, and/or all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) and used for a connection to the PAD300 devices. Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830101. REV J • 5/23 RAGE 2 OF 5 (E)POTTER (I(RA-) The Symbol of Protection Fire Alarm Control P5nel Modules Description ;Device D100-MtM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. D 100-PSSA Single Action Addressable Pull Station. PAD100-PSDA Dual Action Addressable Pull Station. PAD I 00-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD100- TRTl Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD 100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD 100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-IM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD 100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125 VAC. PAD 00-LED Module provides a single addressable LED that is controlled by the control panel. PADIOO-SM Speaker Module provides switching for two audio channels. PAD I 00-LEDK Addressable LED and key switch that mounts in a single gang box. PADl00-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD 100-OROI One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at I25VAC. Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101- REV J • 5/23 PAGE 3 OF 5 (E)POTTER The Symbol of Protection SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green Alarm - Red Earth Fault -Amber Supervisory - Amber Silenced - Amber Trouble - Amber Pre-Release - Amber Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The IPA-loo has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: RA-6075R —2 x 16 LCD annunciator with a key pad in a locked metal enclosure. PA-1OO Fire Alarm CoWff5lPãffë7' RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) - 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the TPA-100 as releasing circuits. CA-6075 - Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 - UL listed, Dual line telephone alarm communicator DRV-50 - LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-I000 - Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 -. Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 - Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three IPA series panels to share a single reporting technology. IDC-6 - Initiating device circuit provides 6 programmable inputs AE-2 - Two card expansion cabinet AE-8 - Eight card expansion cabinet AE-I4 - Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA-100 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders max' be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard Ill IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101- REV J • 5/23 PAGE 4 OF 5 1*1 . . (E)POTTER The Symbol of Protection (IPA-1 oo) Fire Alarm cowfr?irPare"i Dimensions 0 of TOP • DEPTH =3.75 o DOOR = 16.07" BACKBOX = 15.77" DEPTH =3.84" LEFT SIDE RIGHT SIDE BOTTOM Ordering Information Model Description Stock No. (IPA-100) Fire Alarm Releasing Control Panel 3992715 Replacement Board IPA- 100 3992739 Owe #593-1 Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 732 l8BN4TJNLVN0C112CZ 732 12BN4TNLVNOC322C2 Victaulic 753-E Series Mini Max MX 123 & MX200 wl 8876677 & 889323 Viking 11591, 11601, 11602, 13843,& 13844 TLX IPA0036 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVJ • 5/23 PAGE 5OFS :'..... CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 90_9 OFFICE OF THE STATE FIRE MARSHAL Jj9 FIRE ENGINEERING & INVESTIGATIONS DIVISION i BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 77165-0328:0500 CATEGORY: p7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timd@pottersignal.com DESIGN: Models IPA-60 and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module IPAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *SLCE..127 Loop Expander Page 1 of 2 t5 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTES: 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 (E)POTTER (UD-2O The Symbol of Protection Digital Alarm Communicator Features Allows for communication to Monitoring Station Communicates using SIA-DCS or Ademco Contact ID Protocols For use with IPA, AFC, and ARC series Addressable Panels and PFC-4064 Conventional Panel Status LEDs indicate operation of DACT card Installs with ease behind main panel LCD display via User Interface bracket Device address is set internally to address I Includes two (2) RJ45 phone cords <S>O@ LISTED Description The UD-2000 Digital Alarm Communicator Transmitter (DACT) provides for up to two (2) phone lines for communication to a monitoring station. The UD-2000 communicates using the SlA- DCS or Ademco Contact ID protocols. When enabled, the DACT automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the communication is complete, the DACT will hang up. The DACT is provided with terminal blocks for each phone line and two RJ45 cords. In order for the DACT to work properly, it must be installed on a plain old telephone service (POTS) line or equivalent deemed by the authority having jurisdiction. The DACT must be installed before any other equipment to ensure it can seize the phone line. Phone lines are high voltage and should be run in a separate conduit from other circuits. The wire conductors connecting the DACT to the phone system should be 26 AWG or larger. Technical Specifications Operating Voltage 22.0-24.OV Standby Current 16mA Alarm Current 23mA Max UD-2000s per panel Dimensions 4"W * 6"H * 1-5/8"D Operating Tempuratures 0°C - 49°C (32°F- 120°F) Operating Humidity Range 10% - 93% @ 30°C (86°F) (non-condensing) Mounting Options In FACP Behind keypad Shipping Weight 0.47 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830146- REV B • 6/19 PAGE IOF3 (E)POTTER The Symbol of Protection (P -2000 Digital Alarm (Jommunië?itor RJ3 1X Phone Jack to UD-2000 Plain Old Telephone (POTS) lines Tip (Brown) Ring (Grey) Out to Premises Phones Line In From Telco Out to Premises Phones Line In From Telco Installation The UD-2000 DACT is connected to the control panel using the provided four-wire cable connection (P/N 5210514) between P4 and UD-2000 P1. The connection is power limited and supervised. Power system down. Slide the UD-2000 into the card guides located under the User Interface bracket. Secure the UD-2000 to the User Interface bracket using the provided 0-320/8" screw Install the provided four-wire conductor jumper between UD-2000 P1 and P4. Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830146- REV B 6/19 PAGE 2 OF 3 :...., CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-0328:0515 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES rLISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpottersignal.com DESIGN: Models UD-1000 and Digital Alarm Communicator Transmitters (DACT). Refer to listee's data sheet for detailed product description and operational ,considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as a digital alarm communicatior for use with listee's separately listed fire alarm control panels. Refer to listee's Installation Instruction Manual for details. 'NOTES: *Rev 01-09-19 gt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 (E)POTTER PSN-1 000~q The Symbol of Protection (~iPower Expander) Features 10 Amp Power Supply 3 Amps, regulated per NAC 6 NACs Class B or 3 NACs Class A 2 dry contact inputs Fully programmable and monitored through control panel Isolated P-Link repeater connection, Class A or B Up to 31 power supplies per control panel with system wide sync Quadrasync feature synchronizes strobes from AMSECO, Gentex, Cooper-Wheelock and System Sensor. <S> APPROVED 7/65-0328: 0195 S2930 Description The PSN-1000 series is aUL listed intelligent 10 amp notification power supply and P-Link (RS-485) repeater. The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel. The power supply may be installed 6,500 feet from the control panel. The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six (6) Class B or three (3) Class A power outputs. Each output is regulated and power limited with a 3 Amp maximum rating. In addition, the PSN-1000 has two (2) programmable dry contact inputs. The dry contact inputs are Class B, supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output. In addition, the panel can charge up to 55 AH batteries and will house 18 AU batteries. The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish. A standard Potter key lock is provided for securing the door. Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-l000 is a self contained intelligent power supply/P-Link repeater complete with cabinet. The PSN-I000E is the intelligent power supply/P-Link repeater with additional cabinet roomfor mounting stacker bracket modules including PAD 100-SLCE loop expanders. Both cabinets include space for 18 Al-I batteries. Technical Specifications tPSN-l000 163/4"x 16 1/8"x3 1/2" Size (H x W x D) PSN-1000 E: 26' x 17.6' x 3.75" Enclosure Sixteen (16) gauge sheet steel with hinged, locked doors 120 VAC at 50 1-IZ Power Input 240 VAC at 60 HZ 5.1 Amps/3.0 Amps max draw Current Standby 60 mA Alarm 200 mA Temperature 32° to 120°F, humidity 93% non-condensing IPA Series, AFC/ARC Series, PFC-4064, Compatible Panics P Series*, PFC-6000 Adressable Series* * Legacy Product The power supplies are programmed and controlled through the main control panel P-Link bus. The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns, Amseco®, Gentex®, Cooper Wheelock® and System Sensor®. The ouputs can be also configured for constant power, resettable power, sounder base power, door holder power (with or without a low AC drop out), ANSI temporal Code 3, City Tie or be a releasing circuit for 24vdc solenoids. Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830032- REV E • 04/20 PAGE I OF 2 (E.)POTTER The Symbol of Protection LPSN-1000M) Power Expander PSN-1000(E) Intelligent Power Supply III 10 0 £a 0 M. In, .11 '13r. I I •U••••Ii I 1111116. Potter Fire Alarm Control Panel 4 13 0 C3 U 13 41 limill 6 Class 4-Wire P-Link Circuit Class A NAC Circuits P-Link Circuit Repeater rDC) 0 0 III 111 0 Ordering Information Model Description Stock No. (PSN-1000) Power Expander Standard Cabinet 3992662 PSN-1000(E) Power Expander Large Cabinet 3992665 Potter Electric Signal Company, LLC . St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830032- REV E • 04/20 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0328:0195 CATEGORY 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpottersignal.com DESIGN: Models P100, P200, P300, PFC-6030, PFC-6075, PFC-6075R and PFC-6200 fire alarm control units. Automatic, Manual, waterflow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: CA-6075: Class A Expander UD-1000:DACT 3006460, 3006456, 3006467: Main Boards RA-6075, RA-6075R, RA-6500: Remote Annuciators 3005013, 3005012: EOL Resistors (PSN-1000 PSN-1000(E): Fire Power Expander *Models AE-8, AE-14; Power expander enclosures SLCE-127: Loop Expander RATING: 124 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. 'MARKING: I 'Listee's name, model designation, rating and UL label. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE APPROVAL: Listed as fire alarm control units when use with separately listed electrically and tfunctionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. Units meet the requirements of UL Standard 864, 9th edition. NOTES: *Rev. 05-01-13 gt This listing is based upon technical data submitted by the applicant OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational c' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2of2 (E)POTTER __2PAD300-PD? The Symbol of Protection (Photoelectric Smoke Detector Features Low profile, less than 2 inches with the base Wide selectable sensitivity range of 1.1 to 3.50/.lfoot Detector communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting, no programming tool required Magnetic test switch LED alarm indicator Product includes 5-year warranty UUKL Listed for Smoke Control UL268 7th edition compliant Description The Photoelectric Smoke Detector is a listed Analog Addressable smoke detector compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD300-PD is a low profile smoke detector with a wide sensitivity range. The detector and base are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD300-PD has a sensitivity range of 1.1 to 3.5 % per foot and is UL listed. The PAD300-PD features drift compensation and has built in dirty detector warning as well. The PAD300-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The detector is compatible with any of the PAD300 series detector bases and simply twists on. The PAD300-PD is addressed using DIP switches in the rear of the detector and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from I to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. L I soo 0328-054! Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 iiA Alarm Indicator I LED Alarm Set-point Range 1.1 to 3.50/o/ft (3.6 to I l%!m) installation Temperature Range 32 to 120 " F (0 to 49 C) Operating Relative Humidity 0% to 93% (Non-condensing) range Start-up Time Max. I sec. Maximum Number of Addresses 127 Per Loop Maximum Number of Lighted 30 Indicators in Alarm Per Loop Color Eggshell White Weight (without base) 9 1 g (3.20z) Dimensions (without base) Height: 1.42 in (36mm) Diameter: 3.93 in (100 mm) Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 • www.pottersignal.com 8830216- REV B • 2/23 PAGE I OF 2 (E)POTTER LPAD300-PD' The Symbol of Protection Air Velocity Ratings The PAD300-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD300-PD will operate even though the LED may not illuminate. Operation The PAD300-PD is an analog addressable detector that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD300-PD with the PAD300-4DB or PAD300-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The detector includes an insect screen to prevent foreign objects from reaching the chamber and can be cleaned to restore operation of a dirty detector. Detector Sensitivity The PAD300-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the detector is installed over time, the detector compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty detector. The detector will then have to be cleaned or replaced. The PAD300-PD can be programmed to provide a maintenance alert prior to reaching the dirty detector level which will allow for intervention prior to the detector going into trouble. This allows for detector replacement or cleaning prior to a nuisance trouble occurs. NOTE: As required by NFPA, do not install the detectors until all construction is complete and the work area has been thoroughly cleaned. If the detectors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD300-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, 3-1/2" octagon, 3-1/2" square, double gang, 4" octagon, 4" square, 50mm c/c, 60mm c/c and 70mm c/c boxes. Device Description Stock No. PAD300-4DB 4" Detector Base 3992781 PAD300-6DB 6" Detector Base 3992782 PAD300-IB 6" base with an isolator module included 3992783 PAD300-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125 VAC 3992784 PAD300-SB 6" base with sounder module included. Sound pattern is provided from external source 3992785 PAD300-LFSB 6" base with 520Hz sounder module included. Sound pattern is provided from external source 3992786 Ordering Information Model Description I Stock No. (PAD300-PD) Photoelectric Smoke Detector 3992775 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830216- REV B • 2/23 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: J272-0328:0541) -- - CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpottersignal.com DESIGN: Models PAD300-PHD and PAD300-PHD-I Multi-criteria smoke with complimentary heat detector head. Model sAD ___)and PAD300-PD-I Multi-criteria smoke detector head. Products are intelligent addressable photoelectric smoke detector. Model PAD300-PHD employs components for both smoke and heat detection. Model PAD300-PHD-I employs components for both smoke and heat detection along with components for circuit isolation. Model PAD300-PD employs components for smoke detection. Model PAD300- PD-I employs components for smoke detection along with components for circuit isolation. Refer to listee's printed data sheet for additional detailed product description and operational considerations. tiNSTALLATION: '24VDC In accordance with the listees printed installation instructions, applicable codes and lordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: I IListee's name, model number, electrical rating, and UL label. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE APPROVAL: Listed as photoelectric smoke detector and photoelectric smoke detector with complementary heat detector for use with listee's separately listed compatible detector bases and fire alarm control panels. Refer to listee's Installation Instruction Manual for details. Models PAD300-PHD and PAD300-PHD-1 complies with the applicable requirements in UL 268, 7th Edition and UL 521, 7th Edition. Models PAD300-PD and PAD300-PD-1 complies with the applicable requirements in UL 268, 7th Edition. Compatible Detector Bases: Models PAD300-4DB, PAD300-4DB-1,AD300-6DB] PAD300-6DB-1 (CSFM No. 7300- 0328:0539) Models PAD300-SB, PAD300-LFSB (CSFM No. 7300-0328:0544) Models PAD300-I13, PAD300-RB - only for use with models PAD300-PHD and PAD300- PD (CSFM No. 7300-0328:0543) Compatible Fire Alarm Control Panels: Models IPA-60, IPA-100, IPA-4000 (CSFM No. 7165-0328:0500) Models AFC-50, AFC-100, AFC-1000, ARC-100 (CSFM No. 7165-0328:0509) 1-27-23 DAL Jr This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2of2 (E)POTTER (PAD3OO4DB(6DB The Symbol of Protection 4"7(6" Detector Basej' Features Terminals marked with polarity to assist with installation Duplicate Terminals for In-and-out SLC Wiring Terminals accept 22 to 12 AWG wire sizes Installs on Single Gang, Double Gang, Octagon or 4" Square Box Locking tab prevents unauthorized detector removal Product includes 5-year warranty 6" mounting base comes with trim plate cover / 0328-0539 Application The Potter PAD300-6DB and PAD300-4DB detector bases are used to install PAD300 series detectors. The PAD300-6DB will mount on a single gang, double gang, octagon, 4" square, 50mm, 60mm, and 70mm electrical box. Description The PAD300-6DB and PAD300-4DB are low-profile, surface-mount bases used with Potter's addressable detectors. The base uses screw clamp terminals that accept wire ranging from 22 to 12 AWG. When installed on recessed electrical boxes, the PAD300-6DB is wide enough to completely cover the back box and the immediate surrounding area. The base is equipped with a locking tab to deter unauthorized removal of the attached detector. Technical Specifications Installation Temp Range 32°F to 150°F (0°C to 66°C) Operating Humidity Range 0% to 93% (Non-condensing) PAD300-4DB: 3.93 in / 100 mm Dimension PAD300-6DB: 6.3 in / 160 mm PAD300-4DB: 1.34 oz/ 38 g Weight PAD300-6DB: 3.03 oz / 86 g Height 0.76 in / 20 mm Acceptable Wire Gauge 22 to I2AWG Single Gang Double Gang 3-1/2" Octagon Box 4" Octagon Box Mounting Options 4" Square with Plaster Ring 50mm c/c Box 60mm c/c Box 70mm c/c Box Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com PRINTED IN USA 8830203 - REV B • 2123 PAGE I OF 2 (E)POTTER The Symbol of Protection Locking Feature The PAD300-6DB and PAD300-413B include a locking feature that prevents removal of the detector without using a tool. I. To enable this feature, break off the locking tab (See Figure 1), and then install the detector. Fig. 1 2. To remove the detector from the base when the locking feature has been enabled, insert a small screwdriver into the slot on the base to push the plastic tab while simultaneously turning the detector head counter-clockwise. Fig. 2 (PAD30P74DB* B) 4-16" Detector Base Wiring Diagrams Fig. 3 Class B Wiring: Class A Wiring: Class X Wiring: Insert small screwdriver into slot to remove detector from base. Ordering Information Model Description Stock No. PAD300-4DB 4" Detector Base 3992781 (PAD300-6DB) 6" Detector Base 3992782 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com PRINTED IN USA 8830203- REV B . 2/23 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING CATEGORY: 17300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES * LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpottersignal.com DESIGN: Models PAD300-4DB and Detector Base. Models PAD300-4DB-I and PAD300-6DB-I Isolator Detector Base. All models employ the same basic construction, 1and differ only by terminals for circuit isolation. Model PAD300-4DB is a 4 in. (10.2 cm) base with 2 terminal contacts. Model PAD300-6DB is a 6 in. (15.2 cm) base with 2 terminal contacts. Model PAD300-4DB-I is a 4 in. (10.2 cm) base with 3 terminal contacts used for isolation purposes. Model PAD300-6DB-I is a 6 in. (15.2 cm) base with 3 terminal contacts used for isolation purposes. Refer to listees printed data sheet for additional detailed product description and operational considerations. RATING: Electrical ratings can vary depending on compatible detector models used. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: TListee's name, model number, electrical rating, and UL label. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE APPROVAL: Listed as bases for use with listee's separately listed detector heads. Refer to listee's Installation Instruction Manual for details. Models complies with the applicable requirements in UL 268, 7th Edition, UL 521, 7th Edition, and UL 2075, 2nd Edition. Compatible Detectors: Models PAD300-CD and PAD300-CD-1 (CSFM Listing No. 5278-0328:0537) Models PAD300-HD and PAD300-HD-1 (CSFM Listing No. 7270-0328:0538) Model PAD300-DD (CSFM Listing No. 3242-0328:0540) Models PAD300-PD, PAD300-PD-1, PAD300-PHD, and PAD300-PHD-1 (CSFM Listing INo. 7272-0328:0541) Models PAD300-PCD, PAD300-PCD-1, PAD300-PHD, and PAD300-PHD-1 (CSFM Listinc: No. 7275-0328:0542) tNOTES: 1-27-23 VWW This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational 7 requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06130/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2o12 (E)POTTER The Symbol of Protection Features One (I) Class B monitoring input One (1) Form C relay contact SLC ClassA, Class X& Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG Product includes a 5 year warranty (PAD I 00-OR0I) ('O Relay One Input Module) c,M8 4,;-', 4 1~4 UUKL Listed for Smoke Control NOTE: This addressable module does not support 2-wire smoke detectors. APPROVED LLJ "......' Description The PAD 100-OROI uses one (I) SLC loop address when monitoring one (I) Class B circuit and providing one (I) Form C relay contact. The module mounts on either a 4" square or double gang box. The module is capable of monitoring one (1) Class B circuit. The PAD 100- OROI includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When a the input is activated, the LED will flash at a fast rate. Application ThePADIOO-OROI is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD 100-OROT is an interface module used to monitor dry contact devices such as sprinkler waterfiow, valve tamper switches, or conventional pull stations. The module is capable of monitoring one Class B circuit. The PAD 100- OROI also provides one (I) form C relay contact. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 100-OROI. When the PADIOO- OROI is used to monitor one Class B circuit a single device address is assigned, the input and relay are then identified as a sub-point of the module address. For example, if the address number is assigned as "8", the RLYI relay will be "8.1" and the IN input will be "8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24.OV Max SLC Standby 240iA Current Max SLC Alarm Current 240xA Relay Contacts 2A @30VDC, 0.5A @I25VAC Max Wiring Resistance 100 of IDC Max Wiring I iF Capacitance of1DC EOLResistor 5.1KQ Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 • www.pottersignal.com 8830081 - REVD • 12/18 PAGE! 0F2 (E)POTTER The Symbol of Protection DI 00 -ORO!) !)OnOiëIffMö?iiile Installation Using Compatible Electrical Box Fig I Wiring Diagram PADJOO-OROI With One Class B Circuit Fig 2 o ( 0 FROM FACP OR PREVIOUS MODULE SLC L N Ni ul—al __ ®POTFER END-OF-LINE RESISTOR PAD 100-CRC I 5.1KOHM 1/2W Part #3005013 ONE (1) FORM C RELAY CONTACT It is possible that the internal relay in the PAD 100-OROl may be shipped in the non-normal I activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model I Description I Stock No. PAD I 00-OROI) I One Relay One Input Input Module 13992702 Potter Electric Signal Company, LLC St. Louis, MO . Phone: 800-325-3936 . www.pottersignal.com 8830081-REVD • 12/18 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0328:0500 CATEGORY: 17165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdoottersicinaI.com DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PbiOcDROi)One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module , PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module iPAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *SLCE..127 Loop Expander Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: 24VDC [iINSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, rating and UL label. 'APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTES: 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 (E)POTTER The Symbol of Protection Features One (I) Form C relay contact SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG (PAD I 00-RM (Relay Module) Product includes a 5 year warranty UUKL Listed for Smoke Control <~> APPROVED Description The PADIOO-RM uses one (1) SLC loop address to provide one (1) Form C relay contact. The module mounts on either a 4" square or double gang box. The PAD 100-RM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PAD100-RM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD 100-RM is an interface module providing one (1) Form C relay contact. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 100-RM. The PAD100-RM uses a single device address to identify relay contacts. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: I. Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24.OV Max SLC Standby Current 240iA Max SLC Alarm Current 2400 Relay Contacts 2A @30VDC, 0.5A @125VAC Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830084 -REV D 12/18 PAGE 10F2 (E)POTTER The Symbol of Protection (PADI 00-RM RëkffjMö?liile Installation Using Compatible Electrical Box Fig I Wiring Diagram FADIOO-RM Relay Circuit Fig 2 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE ONE (1)FORM C RELAY CONTACTS It is possible that the internal relay in the PADlOO-RM may be shipped in the non-normal I activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model I Description I Stock No. ADl00-RM) I Relay Module 13992705 Potter Electric Signal Company, LLC . St. Louis, MO Phone: 800-325-3936 . www.pottersignal.com 8830084- REV D • 12/18 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION _______ OFFICE OF THE STATE FIRE MARSHAL ____ FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0328:0500 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpottersignal.com 'DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote 1station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's 1lnstallation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module ?AD 1Q0i)Relay Module PAD 100-SIM Single Input Module PAD 100 TRTl Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander 'MC-lOOO Multi-Connect PAD 100-DUCTR AE-2 Enclosure *sLCE..127 Loop Expander Page 1 of 2 :, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION do-girI OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: 24VDC I- INSTALLATION: In accordance with listee's installation instructions, applicable codes & ordinances printed and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTES: 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2of2 tD-i OO-D !Switch S t Remote Tes (E)POTTER The Symbol of Protection Features Supervised Duct Detector Test Switch Active and Pilot LED indicators Key matches the fire alarm control panels Compatible with IPA and AFC/ARC Series panels Mounts in a single gang box All wiring terminals accept 22 to 12 AWG Product includes a 5 year warranty UUKL Listed for Smoke Control Nu i C ACTIVE PILOT TEST NORM > 0 ( 0 APPROVED Description The PADlOO-DRTS module does not require an SLC loop address. The PAD I OO-DRTS provides a supervised remote test switch for the PAD 100-DUCTR duct detector. Active and Pilot LEDs provide status of the PAD 100-DUCTR detector. Keyed switch allows remote testing of the PAD] OO-DUCTR duct detector. Application The PADIOO-DRTS is compatible with Potter's PADIOO-DUCTR Duct detector. It installs on a single gang box. Technical Specifications Operating Voltage 24.OV Max Standby Current lOmA Max Alarm Current 15mA Environmental 32°F- 120°F(0°-49°C) Limitations Indoor Only Operating Humidity 0 to 93% (non-condensing) Range Max no. of Modules Per PAD 100-DUCTR I unit Dimensions 4.75" (187mm) H x 2.75" (lO8mm)W x 1" (40mm)D Mounting Options Single gang box or Potter P32-BB/DBB Shipping Weight 0.65 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830090-REVD 12/18 PAGE! 0F2 (E)POTTER CPADI OO-DRTS) The Symbol of Protection DitRemotTêfSiiJfth Installation Using Compatible Electrical Box Fig I PADIOO-DRTS Back View and Wiring Fig 2 TO ADDRESSABLE PAD1 00-DUCTR DUCT DETECTOR Ordering Information Model I Description Stock No. (PAD lOO-DRTS) I Duct Remote Test Switch 1 3992711 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830090- REV D • 12/18 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0328:0500 CATEGORY: 7165-FIRE ALARM CONTROL UNIT (COMMERCIAL) 'LISTEE: IPotter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timd(DottersiQnal.com DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, water-flow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module 'PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS)Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *SLCEI27 Loop Expander Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 'RATING: '24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTES: 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test '..' results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 Honeywell I Notification Appliances tMGameweII Lj L-Series,(ndoor Strobe and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for(CeilingjApplications General The L-Series audible visible notification products offer the most versatile and easy-to- use product line of horns, strobes, and horn strobes in the industry. This product includes lowercurrent draws and a modern aesthetic design which reduce installation times and maximize profits. In addition, the L-Series offers white and red plastic housings and wall and ceiling mounting options. Similarto the entire L-Series product line, the ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox. These features make installations fast and foolproof while eliminating costly and time-consuming ground faults. To simplify the installation, the L-Series uses a universal mounting plate allowing you to mount the devices to a wide array of backboxes. With an on-board shorting spring, Installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide range of application requirements using the following: Field-selectable candela settings Automatic selection of 12- or 24-volt operation Rotary switch for horn tones with two volume selections Ceiling Horn Strobe FEATURES & BENEFITS Listed for ceiling mounting only Features a plug-in design so that there is minimal intrusion into the backbox Designed with a tamper-resistant construction Provides an automatic selection of 12- or 24- volt operation at 15 and 30 candela Uses field-selectable candela settings on the following ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 Produces horn rated at 88+ dBA at 16 volts Offers a rotary switch for horn tone and two volume selections Includes a universal mounting plate for ceiling units Contains a mounting plate with a shorting spring feature that checks the wiring continuity before device installation Compatible with MDL3 sync module Supports electrical compatibility with the legacy SpectrAlert and the SpectrAlert Advance devices Architect/Engineer Specifications General The L-Series ceiling-mount strobes and horn strobes shall mount to any of the following: double-gang backbox 4-inch octagon backbox a standard 4 x 4 x 1/2-inch backbox Two-wire products shallalso mountto a single-gang compact 2 x 4 x 17/8-inch backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, the L-Series products, when used with the Sync-Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When it is used with the Sync-Circuit Module, the following occur: 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have the following field- selectable candela settings including: .15 .30 .75 .95 115 • 150 • 177 Strobe The strobe shall bean L-Series Model _______ listed to UL Standard 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. Horn Strobe Combination The horn strobe shall be an [-Series Model ______ listed to UL Standard 1971 and U[ Standard 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shalt operate o a coded or non-coded power supply. Synchronization Module The module shall be a Sync-Circuit model MD[3 listed to U[ Standard 464 and shall be approved for fire protective service. The module shall synchronize the L-Series strobes at 1 Hz and synchronize horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single-pair of wires. The module shall mount to a 4 11/6 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style 7 (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. UL Current Draw Table 1 lists the UL maximum strobe current draw. Candela 8-17.5 Volts 16-33 Volts FWR DC DC 15 87 41) 60 30 153 63 86 75 N/A 1111) 142 95 N/A 134 164 115 N/A n18) 191 150 N/A 189 228 177 N/A 226 264 Table 1: UL Maximum Strobe Current Draw (mA RMS) UL Current Draw Data Table 2 lists the maximum UL Current Draw (mA RMS) allowed for 2-Wire Horn Strobes. DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temporal Low 95 166 54 71 124 161 170 216 258 3.1K Temp Hi 111 1164 69 194 147 1163 184 229 1257 3.lK Tern p Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 1217 229 1271 3.1K Non-Temporal 103 169 54 88 131 155 187 1259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temporal Low 78 101 151 172 1199 229 262 3.lK Temporal High 108 135 179 200 225 256 289 3.lK Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1KNon-TemporalLow 79 101 150 171 196 229 260 Table 2 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe Horn Strobe Tones and Sound Output Data Table 3 lists the horn strobe tones and sound output date. Switch Position Sound Pattern dB 8-17.5 Volts 16-33 Volts FWR DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal lHigh 84 89 89 8 3.1 KHz Non-Temporal ILow 77 83 83 Table 3: Horn Strobe Tones and Sound Output Data 6.83" diameter (173 mr 2.47" (62.7 mm) 1.3T'(34.8 mm) L-Series Dimensions Figure 1 illustrates the dimensions for the ceiling-mount horn strobes. Figure 1 Ceiling-Mount Horn Strobes L-Series Dimensions Figure 2 illustrates the dimensions for the ceiling backbox surface mount backbox. 6.92" diameter (l75. Figure 2 Ceiling-Surface-Mount Backbox L-Series Ordering Information Ceiling Horn Strobes: PC2RL: 2-Wire, Horn Strobe, Red PC2WL: 2-Wire, Horn Strobe, White PCARL: 4-Wire Ceiling Horn Strobe, Red, FIRE PCWL: 4Wire Ceiling Horn Strobe, White, FIRE Ceiling Strobes: (SCRL: StrobeR SCWL: Strobe, White SCWL-CLR-ALERT: Strobe, White, ALERT L- Series Dimensions Figure 3 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 32-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox SL Series Dimensions Figure 4 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 44-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox L-Series Ordering Information Accessories: TRC-2: Universal Ceiling Trim Ring Red TRC-2W: Universal Ceiling Trim Ring White SBBCRL: Ceiling Surface Mount Back Box, Red SBBCWL: Ceiling Surface Mount Back Box, White 4 L-Series, Indoor$trobesand Horn Strobes Tech n icaL Specifications SYSTEMS STANDARDS Temperature Ranges: The L-Series, Ceiling Strobes and Horn Strobes are Standard Operating Temperature: 32°F to 120°F (0°C designed to comply with the following standard: to 49°C) UL Standard: UL 1971 and UL 464 Humidity Range: 10 to 93w/a non-condensing Voltages: Strobe Flash Rate: 1 flash per second Nominal Voltage: Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Range2: 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3): 8.5 to 17.5V(12 V nominal) or 16.5 to 33 V(24V nominal) Wire Gage: Input Terminal Wire Gauge: 12 to 18 AWG Dimensions: Ceiling-Mount Dimensions (including lens): 6.8 diameter ° 2.5 high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCR, SBBCW): 6.9 diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: Full Wave Rectified (FWR) voltage is a non- regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C!32 - 120°F and at a relative humidity 93% ± 2/a RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewetl- fci.com/en-US/ documentation/Pages! Listings.aspx E3 Series® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. ALL specifications are subjectto change without notice. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S5512, S4011 CSFM: 7135-1653:0503 7125-1653:0504 ISO 9001 Certification For more information Learn more about Gamewell-FCI's [-Series, Indoor Strobes and Horn Strobes and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeyweII.com 9021-60928 I C I 03/18 ©2018 Honeywell International Inc. Honeywell _______ OFFICE OF THE STATE FIRE MARSHAL ____ FIRE ENGINEERING & INVESTIGATIONS DIVISION CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7125-1653:0504 CATEGORY: 17125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED I ItiSTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, 1 IL, 60174 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: lisa.branthoneywelI.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; CRJ,$CWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: 1BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, WW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: 4TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. NOTES: *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/21/2023 Listing Expires: 06/30/2024 Authorized By: Jeff Schwartz, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 Honeywell Notification Appliances GameIi L-Series,(Indoor)Strobes andHorn Strobes) Indoor Selectable-Output Strobes/Horn Strobes for(Ceilingjpplications / General The [-Series audible visible notification products offer the most versatile and easy-to- use product line of horns, strobes, and horn strobes in the industry. This product includes lower current draws and a modern aesthetic design which reduce installation times and maximize profits. In addition, the [-Series offers white and red plastic housings and wall and ceiling mounting options. Similarto the entire [-Series product line, the ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility white simplifying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox. These features make installations fast and foolproof while eliminating costly and time-consuming ground faults. To simplify the installation, the [-Series uses a universal mounting plate allowing you to mount the devices to a wide array of backboxes. With anon-board shorting spring, Installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide range of application requirements using the following: Field-selectable candela settings Automatic selection of 12- or 24-volt operation Rotary switch for horn tones with two volume selections Ceiling Horn Strobe FEATURES & BENEFITS Listed for ceiling mounting only Features a plug-in design so that there is minimal intrusion into the backbox Designed with a tamper-resistant construction Provides an automatic selection of 12- or 24- volt operation at 15 and 30 candela Uses field-selectable candela settings on the following ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 Produces horn rated at 88+ dBA at 16 volts Offers a rotary switch for horn tone and two volume selections Includes a universal mounting plate for ceiling units Contains a mounting plate with a shorting spring feature that checks the wiring continuity before device installation Compatible with MD[3 sync module Supports electrical compatibility with the legacy SpectrAlert and the SpectrAlert Advance devices Architect/Engineer Specifications General The [-Series ceiling-mount strobes and horn strobes shall mount to any of the following: double-gang backbox 4-inch octagon backbox a standard 4 x 4 x 1 1/2-inch backbox Two-wire products shall also mountto a single-gang compact2 x 4 x 17/8-inch backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, the [-Series products, when used with the Sync-Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When it is used with the Sync-Circuit Module, the following occur: 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have the following field- selectable candela settings including: .15 .30 - 75 .95 115 • 150 • 177 Strobe The strobe shall be an [-Series Model ______ listed to UL Standard 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. Horn Strobe Combination The horn strobe shall bean [-Series Model ______ listed to UL Standard 1971 and U[ Standard 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern, These options are set by a multiple position switch. The horn on horn strobe models shalt operate o a coded or non-coded power supply. Synchronization Module The module shall be a Sync-Circuit model MD[3 listed to UL Standard 464 and shalt be approved for fire protective service. The module shall synchronize the [-Series strobes at 1 Hz and synchronize horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single-pair of wires. The module shall mount to a 411/6 x4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. UI. Current Draw Table 1 lists the U[ maximum strobe current draw. Candela 8-17.5 Volts 16-33 Volts FWR DC DC 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 1 N/A 226 1264 Table 1: UL Maximum Strobe Current Draw (mA RMS) UL Current Draw Data Table 2 lists the maximum UL Current Draw (mA RMS) allowed for 2-Wire Horn Strobes. DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 i) Oi) 165 ii) 217 2511 Temporal Low 96 165 54 71137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temporal Low 95 1166 54 171 1214 161 1170 216 1258 3.1K Temp Hi 111 164 69 94 147 163 184 229 257 3.lK Temp Low 103 163 54 88143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal 103 169 54 88 1131 155 187 1217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temporal Low 78 101 151 172 199 229 1262 3.lK Temporal High 108 135 179 200 225 256 289 3.lK Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High108 135 179 200 225 255 289 3.1K Non-Temporal Low 179 1101 150 171 196 229 260 Table 2 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe Horn Strobe Tones and Sound Output Data Table 3 lists the horn strobe tones and sound output date. Switch Position Sound Pattern dB 8-17.5 Volts 16-33 Volts FWR DC DC 1 temporaL High) 84 1 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.l KHz Temporal High 83 88 88 6 3.l KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 189 89 8 3.1 KHz Non-Temporal Low 177 183 83 Table 3: Horn Strobe Tones and Sound Output Data 6.83" diameter (173 mr 2.4'r'(62.7 mm) 1.3T'(34.8 mm) L-Series Dimensions Figure 1 illustrates the dimensions for the ceiling-mount horn strobes. Figure 1(ci!2 g-Mount Horn Strobes) L-Series Dimensions Figure 2 illustrates the dimensions for the ceiling backbox surface mount backbox. 6.92' diameter (175; Figure 2 Ceiling-Surface-Mount Backbox L-Series Ordering Information Ceiling Horn Strobes: (PC2[)-Wire, Horn Strobe, Red PC2WL: 2-Wire, Horn Strobe, White PC4RL: 4-Wire Ceiling Horn Strobe, Red, FIRE PCAWL: 4Wire Ceiling Horn Strobe, White, FIRE Ceiling Strobes: SCRL: Strobe, Red SCWL: Strobe, White SCWL-CLR-ALERT: Strobe, White, ALERT L- Series Dimensions Figure 3 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 32-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox SL Series Dimensions Figure 4 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 44-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox L-Series Ordering Information Accessories: TRC-2: Universal Ceiling Trim Ring Red TRC-2W: Universal Ceiling Trim Ring White SBBCRL: Ceiling Surface Mount Back Box, Red SBBCWL: Ceiling Surface Mount Back Box, White i64em) 4 L-Series,(Indoor strobes andrn_ Strobes )Tech n i caL Specifications SYSTEMS STANDARDS For a complete Listing of all compliance approvals and Temperature Ranges: The L-Series, Ceiling Strobes and Horn Strobes are certifications, please visit: Standard Operating Temperature: 32°F to 120°F (0°C designed to comply with the following standard: http://www.gamewetl- to 49°C) UL Standard: UL 1971 and UL 464 fci.com/en-US/ documentation/Pages/ Humidity Range: 10 to 93% non-condensing AGENCY LISTINGS AND APPROVALS Listings.aspx Voltages: Strobe Flash Rate: 1 flash per second Nominal Voltage: Regulated 12 VDC or regulated 24 DC/F WR1 Operating Voltage Range2: 8 to 17.5 V (12 V nominal) or 16 to 33 V(24 V nominal) Operating Voltage Range (MDL3): 85 to 17.5V(12 V nominal) or 16.5 to 33 V(24V nominal) Wire Gage: Input Terminal Wire Gauge: 12 to 18 AWG Dimensions: Ceiling-Mount Dimensions (including lens): 6.8 diameter x 2.5 high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCR, SBBCW): 6.9 diameter x 3.4 high (175 mm diameter x 86 mm high) Notes: Full Wave Rectified (FWR) voltage is a non- regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 491C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 31F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F. For more information Learn more about Gamewell-FCI's L-Series, Indoor Strobes and Horn Strobes and other products available by visiting www.Gamewell-FCl.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9021-60928 I C I 03/18 Honeywell ©2018 Honeywell International Inc. These listings and approvals apply to the modules E3Series°and Gamewell-FCl specified in this document. In some cases, certain are registered trademarks of modules or applications may not be listed by certain Honeywell International Inc. approval agencies, or listing may be in process. Consult factory for latest listing status. UL° is a registered trademark of Underwriter's Laboratories UL: S5512, S4011 Inc. CSFM: 7135-1653:0503 7125-1653.0504 This document is not intended to be used for installation ISO 9001 Certification purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. Allspecifications are subjectto change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 17135-1653:0503 [CATEGORY: 7135 - AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: BraritLisa (203) 484-6105 (203) 484-7309 Email:lisa.branthoneywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models IHWL, HRL, HGWL and HGRL Horns; :cHwL and CHRL Chimes; 1P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RLJ PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC.F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, 1BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W Page 1 of 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listees printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listees Installation Instruction Manual for details. IJf%T. Revision 08-21- 2017 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational c. requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Page 2 of 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Date Issued: 04/21/2023 Listing Expires: 06/30/2024 Authorized By: Damon Lam, Program Coordinator Fire Engineering & Investigations Division Page 3 of 3 U L Applicant ID No: 892912-001 I Service Center No: I I Expires: 31-MAR-2024 I CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Comoanv indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: HUNTINGTON BEACH, CA (HUNTINGTON BEACH) Alarm Service Company: (892912-001) Service Center: (892912-001) GENERAL MONITORING SERVICES INC GENERAL MONITORING SERVICES INC 17951 LYONS CIR 17951 LYONS CIR HUNTINGTON BEACH CA 92647-7167 HUNTINGTON BEACH CA 92647-7167 The Alarm Service Company is Listed in the.followingCertific S78944 UUFX/' [Signal—and Fire Alarm Equip / Services) Central Station Service Categories: and Services] (Protective Signaling I / ***THIS CERTIFICATE EXPIRES ON 31MAR2O24** / / / / / "LOOK FOR THE UL ALARM SYSTEMCERTIFICATE" / N /