HomeMy WebLinkAbout2525 EL CAMINO REAL; ; FA050081; Permit11/21/24, 9:53 AM FA050081 Permit Data City of Carlsbad Fire Alarm Permit 2525 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 1563020900 Lot #: 0 Reference No.: Permit No: FA050081 Status: ISSUED Applied 8/18/2005 Approved: 8/22/2005 Issued: 8/22/2005 PC #: Inspector: Project Title: TACO DEL MAR, SUITE 104 FIRE ALARM INSPECTION Applicant: SIMPLEX GRINNELL 9855 CARROLL CANYON RD SAN DIEGO CA 858-740-0100 Owner: PLAZA CAM INO REAL C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 55 0 55 0 about:blank 1/1 FA05ooS I SirnplexGrinnell LP 9855 Carroll Canyon Road fi San Diego, CA 92131 Security tqca / Fire & IS P1 Xor i nne Tele: (858) 740-0100 I Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM PRODUCT SUBMITTAL PROJECT: Taco Del Mar Plaza Camino Real Space #104 2525 El Camino Real Carlsbad, CA 92008 COPY ApPROVED pd 5((Z4 0) CITY OF C FIRE DEPARTM0 E APPROVED AS TOTED subject to APPROVED D NOT APPROVED RESUBMIT tests notations field IflSPCctjon a CHECIUG IS ONL FORMANY FOR CO T1,11 GONTWUT correspondence' hereon, TH ri OEGN CONCEPT THE C.~,Jt"TRACJOIR IS applicable regulations, and conformance conditions in PPOEOT AD COfl WITH THE I , s 2 not be held to per 02 Dates ( £ AND IORkEL -ED AT THE JOB - SITE HD FOR COORUttTO OE IN WORK OF ALL TRP.D. 8/9/2005 REV.#: 0 PROJECT #: 480-402025-01 ,-' tqca /Fire & / SimplexGrinnell Security SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM ITEM QTY MODEL NO. DESCRIPTION C.S.F.M. NO. A 1 4004-9101 Fire Alarm Control Panel 7165-0026:213 2 2081-9272 6.2AH Battery N/A B 3 4098-9788 2 Wire Base with LED 7300-0026:222 3 4098-9601 Photoelectric Smoke Detector 7272-0026:219 C 1 4098-9686 Duct Detector Housing 3240-0026:241 1 PAM-SD Interposing Relay 7300-1004:101 1 4098-9834 Remote Alarm LED 7300-0026:150 D 1 4090-9101 Monitor ZAM(Ties to Mall System) 7300-0026:223 E 1 4905-9914 Sync Module 7125-0026:248 F 1 4906-9104 Strobe Only Multi-Candela 7125-0026:316 8/9/2005 REV.#: 0 PROJECT #: 480-402025-01 935implex UL Listed FM, CSFM, and NYC, MEA Approved* STANDARD FEATURES Two initiating device circuits (lDCs): - Style B (Class B), expandable to eight - Five programmable operation modes - Internal DACT (standard 4004-9101 & -9102) - Service Disconnect and Alarm Verification are selectable per zone - Fifteen second 'Abort Enable" Two Style Y (Class B) notification appliance circuits (NACs): - Up to four (4) amps, two amps each NAC - General alarm operation - Each selectable for on-until-silence or on-until-reset operation - Five coding options - Programmable alarm cutout - Common disconnect switch for circuit disable Compatible with: - Simplex® 4003 Voice Control Panels, 4009 NAC Power Extenders, and 4601 Series Remote LED and LED/Switch Annunciators Panel features and operation: - Two, seven segment LED status and diagnostic displays - Selectable alarm silence/reset inhibit - Power limited design - Dedicated supervisory status and alarm silenced status LEDs - Selectable active status reminder - WALKTESTTm performance testing** - Auxiliary outputs for alarm, supervisory, and trouble Single chassis assembly with large wiring terminals for easy wiring Easy semi-flush or surface installation: - Semi-flush mount between 16" stud centers - Built-in trim plate for semi-flush mounting - Drywall alignment tabs and nail knockouts - Beige or red cabinet Optional features: - Remote Station/City Connection - Style D/Style Z (Class A), two circuit zone conversion module - Multi-purpose annunciator interface - Internal and remote relay modules NOTE: Contact your local Simplex product supplier for fire alarm control panels suitable for Release Control applications. LifeAlarm® Fire Alarm Controls Fire Alarm Controls 4004 Series Fire Alarm Control Panels; Two to Eight Zones a. a 0!8 u• ... a. a. a.. a-.... a... a. an 88,88 union 4004-9101 Fire Alarm Control Panel (shown with zone labels applied) INTRODUCTION Simplex 4004 Series fire alarm control panels provide easy installation, flexible initiating circuit monitoring, and extensive programmable control capability for areas requiring two to eight IDC zones. Installation ease has been considered throughout, from cabinet design to quick and easy setup. By employing surface mount components, seven segment LEDs, and efficient microprocessor programming, an extensive feature list is provided in a cost-effective and compact package. Panel status is efficiently indicated by discrete LEDs and an alphanumeric zone indicator/diagnostic display. Panel control switches are clearly marked for easy operation. Programming of the selectable features is quickly performed using the LED display and the panel control switches. APPLICATIONS The 4004 Series fire alarm control panel provides protection for a wide variety of smaller facilities in the following fields: Educational, Health Care, Business, Storage, Hospitality, Residential, and General Assembly. Due to its modular construction, the 4004 can be ordered with only the features needed. If the system expands, then additional modules (up to eight zones) can be easily installed on-site. ** WALKIEST performance testing is protected under US Patent No. 4,725,818. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:213 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. This product was not ULC listed as of document revision date. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. S4004-0001-6 7/02 4004 Display/Control Panel CONTROL PANEL FEATURES Alarm Indication Upon receiving an alarm, the Fire Alarm Zone LED displays the number of the alarmed IDC. If multiple IDCs are in alarm, each number will alternately be chronologically displayed. During this time, the internal tone-alert signal will be sounding and the NACs will be operating as programmed. Alarm Silence To silence the alarm, the 'ALARM SILENCE" switch is momentarily pushed and the "ALARM SILENCED" LED will light. Repeated use of the "ACK" switch will scroll through the alarmed zone numbers in chronological order. Supervisory or Trouble Conditions Supervisory conditions are for monitoring devices such as waterilow tamper switches - conditions more serious than a trouble, but not considered an alarm. Troubles include open, shorted, or earthed wiring, AC power loss problems, or other indications (refer to trouble list below). The trouble type is displayed alphanumerically on the LED digits using upper and lower case letters and the period. LED Trouble Identification List IDC Zone Number IDC Auxiliary Output Annunciator Card Trouble Supervised Auxiliary Alarm Output Trouble Battery Low Trouble City Circuit Trouble Configuration Trouble Depleted Battery Trouble NAC 1 Trouble NAC 2 Trouble WALKTEST Enabled (System is in WALKTEST "Trouble") Program Trouble Power Supply Trouble Ground Fault Trouble Supervisory Condition Indication Supervisory conditions are annunciated by flashing the yellow Supervisory LED and activating the tone-alert and the common supervisory output. Supervisory zones are numerically displayed on the red Fire Alarm Zone indicator LED display with a decimal point identifier. Using the ACK switch will scroll the zone numbers chronologically. Alarm Acknowledge Momentarily pressing the "ACK" switch will acknowledge the alarm condition and will silence the local tone-alert signal. Supervisory Acknowledge During Supervisory conditions, the yellow SUPERVISORY LED will stop flashing and remain "on" until the condition is cleared and the panel is reset. Trouble Acknowledge During Trouble conditions, the yellow TROUBLE LED display identifies the specific trouble(s), chronologically scrolling through multiples troubles. Multiple Battery Status Monitoring Batteries are monitored for both presence and proper charging. Additionally, in the event that battery operation extends beyond the available battery capacity, a depleted battery trouble signal will warn when the battery charge is approaching depletion. WALKTEST Performance Testing Simplex WALKTEST performance testing allows a single fire alarm system tester to manually initiate remote troubles and alarms and obtain a verification output from the NACs with an automatic Reset. Alarms are initiated to produce a zone identifying pulse count. With the zone number confirmed, troubles can then be initiated and confirmed with a common pulse output. Inside Front Door Information A reference label inside the front door provides extensive information concerning the following. Emergency operating instructions Fire alarm indicators Trouble indicators Site-specific zone descriptions (custom labels) Programming instructions Panel layout and module location Terminal identification for on-site wiring 4004 OPERATION/PROGRAMMING OPTIONS IDC Operation Standard IDCs are low current and support up to 20 Simplex detectors per IDC, 2 mA maximum. (For detectors with relay bases, use high current expansion modules, see chart on page 3). For further information, refer to field wiring diagram 841-992 and Installation Instructions 574-074. IDCs are individually programmable as: Standard Fire Alarm Alarm Verification Fire/Supervisory Trouble Only or for Current Limit Devices Only (Style C) S4004-0001-6 7/02 page 2 4004 PROGRAMMING OPTIONS (Continued): GENERAL OPERATION Selectable Active Status Reminder is available to provide a reminder every 8 hours that an acknowledged condition still exists Common Outputs for Alarm, Supervisory, and Trouble, 24 VDC, 150 mA open collector relay or LED driver; Common Alarm is supervised the same as the Auxiliary Alarm output Internal Dual Line DACT module has automatic 24 hour test and programmable power fail report delay (standard on models 4004-9101 and 4004-9102) NAC OPERATION/FEATURES General Alarm Operation. Standard is NAC I On-Until-Silenced (to manually silence audible notification appliances) and NAC 2 On-Until-Reset (maintains visible notification until the system is restored to normal); each can be jumper selected as either type Notification Coding is programmable as: Steady Signaling, Temporal Pattern, March Time @ 20 BPM, March Time @ 120 BPM, or Simple Coding (Simple coding is a repetitive code equal to the zone number that initiated the alarm) Supervised Auxiliary Alarm Output per IDC, 24 VDC, 150 mA open collector driver, current limited, UL listed for Pilot duty; provides auxiliary control and circuit supervision of a compatible annunciator or remote relay for emergency control in accordance with NFPA 72 and NFPA 101 NAC OPERATION/FEATURES (Continued) Signal Silence Inhibit is programmable as: 0, 1, 2, 3, 4, or 5 Minutes (time after alarm occurs that Signal Silence Switch will be intentionally unable to silence alarm) Alarm Silence Cutout is programmable as 0, 10, 20, or 30 minutes (time after alarm when automatic silence occurs) OPTIONAL ON-SITE INSTALLED MODULES Standard Low Current Operation, 2 IDC and 4 IDC modules, for up to 20 detectors per IDC, 2 mA maximum detector power (for detectors without relay bases) High Current Operation, 2 IDC and 4 IDC modules, for up to 30 detectors per IDC, 3 mA maximum detector power (for detectors with relay bases) Dual Circuit City Connection module, selectable as local energy or reverse polarity; Reverse polarity is selectable for Alarm/Trouble, Alarm, Supervisory, or Trouble only reporting (available with or without disconnect switches) Class A (Style DlStyle Z), 2 Circuit Adaptor module for either lDCs or NACs Supervised Annunciator Interface module, 3 inputs (remote Reset, ACK, and Silence), and 4 outputs (Trouble, Supervisory, Alarm Silenced, Remote Sounder), 24 VDC, current limited, 150 mA open collector each Relay Module provides separate dry contact outputs for Alarm, Supervisory, and Trouble; selectable as N.O. or N.C.; rated 2 A @ 32 VDC 4004 Model Selection Chart TdI 'Description Standard Control Panels (4004-910j) Beige Cabinet 120 VAC, 60 Hz 40049102* Red Cabinet 4004 Fire Alarm Control Panel, Class B Operation, 2 lDCs, 2 NACs, 4004-9201 Beige Cabinet 220/240 VAC, 50/60 Hz with 4 A Power Supply 4004-9202 Red Cabinet Expansion Modules 4004-9802 2 Point IDC, Class B I Standard Operation, for detectors without relays I Select one maximum 4004-9822 I High Current Operation, for detectors with relay bases 04-98 4 Point IDC, Class B I Standard Operation, for detectors without relays Select one maximum 4004-9824 I I High Current Operation, for detectors with relay bases Optional Modules 4004-9806 Class A (Style D/Style Z) Two Circuit Adaptor Five (5) maximum 4004-9808 Annunciator Interface, 3 Inputs, 4 Outputs Select one maximum 40049809* City Connect Module, 2 Circuits, with disconnect switches Select one maximum 40049829* City Connect Module, 2 Circuits, without disconnect switches 40049810* Internal DACT, connects to RJ31X Telco jacks, requires one DACT cable/line 40049803* Relay Module; Alarm, Supervisory, and Trouble relays Batteries** (2081-9272) 1 6.2 Ah battery, typical for 24 hour standby, 2 required Select one as required 774 110 Ah battery, typical for 60 hour standby, 2 required Accessories (select as required) 1 I Four alarm relays mounted on a 6 gang plate; coils require 20 mA each at 24 VDC; contacts are rated 1/2 A at 4001-9810 120 VAC, 2 A at 30 VDC, resistive (refer to data sheet S4001-0003) 4601 Series Remote LED and LED/Switch Annunciators (refer to data sheet S4601-0002) 2080-9047 DACT cable with RJ45 oluci. 14 ft lona (4.3 m). reauired for DACT use * 4004-9101 and 4004-9102 include a DACT as standard equipment. Operation allows for either a City Connection Module, or a DACT Module, or a Relay Module. 4004-9810 is for aftermarket add-on. The DACT module is programmed using a terminal or a laptop computer in terminal emulation mode. Connection and programming details are provided with the installation instructions (publication 574-049). ** Refer to Field Wiring Diagram 841-992 for battery selection. S4004-0001-6 7/02 page 3 t7 B.x incls . d m s einsl.048" (1 .22 mm) thick tnn trim or i_f u h mounting. Height and Width are same as door. 3-7/8° (98 mm) TKnockouts are I provided for nailing. I Two on each side I 1/2' and one each on top Land bottom. (13 mm Specifications f JUtPOWer 102-132 VAC, 60 Hz 2 A maximum 204-264 VAC, 50/60 Hz 1 A maximum - Auxiliary Alarm Outputs 150 mA @ 24 VDC, open Common ALM, supv, TBL collector, current limited Resettable Smoke Detector 500 mA @ 24 VDC, open Power collector, current limited Auxiliary Power 2 A maximum @ 24 VDC Alarm, Supervisory, and Trouble 4004-9803 Relay relays, each relay output is rated 2 A maximum @ 32 VDC; selectable as N.O. or N.C. [vimnmental Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range 10% to 93% RH, non-condensing @ 90° F (32° C) Mounting Dimensions Module Currents* Module Supv. Current Current 82 mA** Base Panel, 120 or 240 VAC 52 mA 4004-9802, 2 IDC, Low Current 7 mA 38 mA** 4004-9804, 4 IDC, Low Current 14 mA 45 mA" 4004-9822, 2 IDC, High Current 14 mA 86 mA** 4004-9824, 4 IDC, High Current 27 mA 94 mA** 4004-9806, Class A Adapter 0 mA 0 mA 4004-9808, Annunciator Interface Module 4 mA 4 mA + Annun. loads 4004-9809 2 Circuit City Connect Modules 20 mA 36 mA 4004-9829 1 DACT Module (4004-9810) 30 mA 45 mA 4004-9803 Relay Module 10 mA 37 mA * Note: Add IDC 2-wire detector current and NAC loads for total. Refer to Field Wiring Diagram 841-992 for battery selection and additional detail. ** Conditions: Both NACs on; one IDC in alarm per module, remaining lDCs in supervisory mode. Add NAC loading and 2-wire detector load current per application. Reference, 16" Stud Centers 7 Box Width = 14-1/2° (368 mm) ..... :• •.• .-u ••••.. .,. .. .. U. •IIU Door Height 16-7/8' (429 mm) .. .. .,. U• •• •• •U U •'U U.•.• •U •.• au •• •• U. •• •U •u •.0 •.•u•. .1 •U •U •• •• •• U. •• U• ,. U U•• •.•,•U •'• U .UU U-U. U• •.f• Width = 15-5/16° (389 m Ho 'Drywallmarkers indicate .7 mm) depth, each side. 16" (406 mm) NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. Tvco, Simplex, the Simplex logo, L(feAlarm, and WALKTEST are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 70, NFPA 72, and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). SirnpIex TEPG-US • 91 Technology Drive • Westminster, Massachusetts • 01441-0001• USA S4004-0001-6 7/02 © 2002 TEPG-US (a Tyco company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:213 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Mod ~,cal, 9102, -9201 and -9202 fire alarm control units. Power-limited, coded, non-c ocal, auxiliary, remote station, proprietary and central station fire alarm service; automatic, manual and waterfiow alarm and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 565-573 System Board 4004-9802, -9804, -9822, -9824 Initiating Expander Board 4004-9806 Style Z Adapter 4004-9809,-9829 City Connect Board 4004-9808 Annunciator Interface Board 2080-9044 DACT 4004-9810 DACT 2088-9007 Shunt Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire control units for use with separately listed compatible initiating and indicating devices. The control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to listee's Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature, the maximum Retard/Reset/Restart must be adjusted to 30 sec. or less. Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Multi-Application Peripherals 935implex and Accessories Batteries and Chargers 2081 Series System Batteries, 6.2 Ah to 50 Ah FEATURES Rechargeable, sealed lead-acid design: - Lead-calcium grid structure - Immobilized electrolyte in absorbent separator - High reliability dual seal construction - Low maintenance, no need to add water - Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities DESCRIPTION Simplex rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see Figure 1, page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. SPECIFICATIONS Nominal Voltage Rating...............................12 V/battery Discharge Rating.......................................20 Hour Rate Typical Charge/Discharge Cycles .................100 to 150 Preferred Charge Temperature Range .... 600 F to 90° F (15.6° C to 32.2° C) - These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact Simplex for proper battery selection per system requirements. Sealed Lead-Acid Batteries for Panel Mounting APPLICATIONS Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through Simplex Service.) Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. © 2000 Simplex Time Recorder Co. All rights reserved. S2081-0006-15 6/00 Qnc.Ind ni .+nr ,'e,nr Cell case (high impact polystyrene) Inner Absorb used Lead- SEALED LEAD ACID BATTERY CONSTRUCTION DETAILS: (actual appearance will vary with battery size) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator Figure 1. Battery Construction Reference S2081-0006-15 6/00 page 2 BATTERY SPECIFICATIONS AND SELECTION CHART Battery Mechanical Specifications* Battery Model Ah, 20 Hour Width Depth Height with Approximate Weight Rate(Ah) Terminals 6.2 6 1/8" (156 mm) 2 5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 6" (153 mm) 4 1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 6" (153 mm) 4" (102 mm) 4(102mm) 9 lbs (4.1 kg) 2081-9275 18 7 1/4" (184 mm) 3 3/8" (86 mm) 6 5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 6 5/8" (168 mm) 5" (127 mm) 7" (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular) 33 12 1/2" (318 mm) 3 3/8" (86 mm) 7 1/16" (179 mm) 26.6 lbs (12.1 kg) 2081-9276 (square) 33 7 3/4" (197 mm) 5 1/4" (133 mm) 6 3/4" (171 mm) 26.5 lbs (12 kg) 2081-9296 50 9 1/2" (241 mm) 5 1/2" (140 mm) 87/8" (225 mm) 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Selection Chart for Fire Alarm Control Panel Mounting Battery Ah, 20 Simplex Control Panel Series (see legend and notes below) Model Hour Rate - .., -. -. 4020 4100/4120 4003 4004 4005 4009 4010 (2,4or 6-Unit) (2,4or_6-Unit) 6.2 Yes 2081-9274 10 Yes 2081-9288 12.7 Yes Yes Yes Yes Yes 2081-9275 18 Ext Note 1 2081-9287 25 Ext Yes Ext 2081-9271 (rectangular) 33 Note 3 Note 2 Ext 2081-9276 33 Yes (square) Ext 2081-9296 (Note 4) 50 Ext Yes = Can be placed in the respective equipment cabinet Ext = External battery cabinet required, refer to selection chart on page 4 Shaded area = Not applicable NOTES: 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. Refer to individual fire alarm control panel product data sheets for additional battery application information. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact Simplex for proper battery selection per system requirements. S2081-0006-15 6/00 page 3 EXTERNAL BATTERY CHARGER AND CABINET REFERENCE External Battery Cabinets - - Externally Mounted Battery Battery Cabinets without Chargers Battery Ah, 20 Cabinets with Chargers (connects to charger in panel) Model Hour Rate. AIQ4 2081 9301'206-9303-2081 .Series 9270* zD81 -9281 2081 9282 4009-9801 4009-9802 2081-9275 18 Yes 2081-9287 25 Yes Yes 2081-9271 Yes 33 2081-9276 2081-9296 50 Yes * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. Yes = Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specifications Model Description Color, '.Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25 3/4" W x 20 3/4" H x 6 3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 2081-9270t External battery cabinet without charger 26 1/2" W x 12" H x 12" D 2081-93011 External battery cabinet with charger Red (673 mm x 305 mm x 305 mm) 2081-9303t er1 battery cabinet with charger and with meters for voltage and current 4009-9801 External battery cabinet without For up to 18 Ah 16 1/4" W x 13 1/2" H x 4 1/8" D charger, with solid door and battery harness, for close-nippled mounting batteries Bei e g (413 mm x 343 mm x 105 mm) 4009-9802 For up to 33 Ah 25 3/4" W x 20 3/4" H x 4 1/8" D to fire alarm control panel cabinet batteries (654 mm x 527 mm x 105 mm) 4081 Companion cabinet and charger for For up to 50 Ah Available in beige 22 1/2" W x16 3/4" H x 83/8" D Series1 the 4010 fire alarm control panel batteries or red (572 mm x 425 mm x 213 mm) t Refer to Simplex data sheet S2081-0002 for additional information. tt Refer to Simplex data sheet S4081-0001 for additional information. Simplex and the Simplex logo are registered trademarks of the Simplex Time Recorder Co. S2081-0006-15 6/00 5SirnpIec Westminster, Massachusetts 01441-0001 U. S. A. Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnef.com All specifications and other information shown were current as of printing and are subject to change without notice. £5Simplex UL, ULC Listed; FM, CSFM, and MEA (NYC) Approved* I ui* Photoelectric smoke detector with on-board TrueAlarm sensitivity drift compensationt UL listed to Standard 268 Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: 4098-9601, Standard Sensitivity, nominal 2.8%/fl obscuration 4098-9605, Special Application Sensitivity, nominal 3.5%/fl obscuration Available base options: Bases for 2-wire or 4-wire operation Auxiliary alarm relay output Optional remote alarm indicating LED Simplex® TrueAlarm photoelectric detectors provide many of the proven TrueAlarm analog sensing features for applications where detectors are connected to conventional 2-wire or 4-wire initiating device circuits (IDCs). Each TrueAlarm detector has an on-board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. TrueAlarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high performance smoke capture abilityt. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. TrueAlarm® Smoke Detectors TrueAlarm Photoelectric Smoke Detectors for Two-Wire and Four-Wire Bases 4098-9601 TrueAlarm Photoelectric Detector Mounted in Base Specifications Voltage 15 to 32 VDC from Fire Alarm Control Panel IDC Standby Current 100 1iA @ 24 VDC Alarm Current, 2-Wire Up to 86 mA maximum, exact current is Operation determined by alarm current limiting of connected lDC Alarm Current, 4-Wire Operation 24 mA typical @ 24 VDC Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0.2000 ft/mm (0-610 rn/mm) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 15° to 122° F (-9° to + 50° C) Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non-condensing Color Frost White 4-7/8" Dia. x 1-7/8" H, mounted in base Dimensions (124 mm x 48 mm); refer to page 3 for detail * ULC listed models are designated with a "C' suffix such as 4098-9601G. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7272-0026:219 for allowable values and/or conditions concerning material presented in this document It is subject to re- examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. t TrueAlarrn smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; 0388,352; 0392,573. S4098-0015-5 10/02 Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accumulation of dust and dirt. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. (See page 3.) V±19M lTtaT11 ti 1:1 i:1iT.1:J Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke detector spacing of 30 ft (9.1 m) may be used as a guide. For detailed installation information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). Sensitivity Selection. The 4098-9601 standard sensitivity detector is recommended for most applications. When a special application for a reduced sensitivity detector is required, the 4098-9605 should be considered. Consult your local Simplex product supplier for assistance in determining the proper selection. diitt SItir Smoke Detectors Model' Description Nominal Sensitivity CotblIiti ,4098-9601 TrueAlarm Photoelectric Detector 2.8%/ft (standard) Compatible with bases: 4098-9788, 4098-9682, and 4098-9605 3.5%/ft 4098-9683 Compatible Bases ijescripuon - ueIaiIs: 4098 9788 2-Wire Base with connections for IDC and LED connections are screw terminals for in/out wiring, - Remote Alarm LED Indicator 1 18 to 14 AWG 4-Wire Base with Auxiliary Alarm Relay Contacts and connections for 4098-9682 Remote LED Alarm Indicator !QIg: Requires external 24 VDC for operation Relay Ratings, Single Form "C", For Suppressed Loads: Power limited, 3 A @ 28 VDC; Non-power limited, 3 A @ 120 VAC Wiring Connections (In/Out where required): Relay contacts and IDC wiring, color coded 18 AWG leads; LED wiring, screw terminals for 18 to 14 AWG 4098-9683 2-Wire Base with Auxiliary Alarm Relay Ratings, Dual Form "C", For Suppressed Loads: Relay & connections for Remote LED Power limited, 1 A @28 VDC; Non-power limited, 1/2 A @ 120 VAC Indicator NOTE: Must be connected as the only I Wiring Connections (In/Out where required): device on the IDC to ensure relay I Relay contacts and IDC (-), color coded 18 AWG leads; operation. IDC (+) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories Model - Description Details -_ Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes 4098-9832 I Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098-9788, -9682, & -9683 4098-9830 1 Remote LED Indicator I Mounted on single gang stainless steel plate 2098-9739 Encapsulated I Dimensions: 2-1/2" x 1-1/2" x 1" Required for 4-wire circuits using 24 VDC (64 mm x 38 mm x 25.4 mm) i 4098-9682 base, one per circuit; select I End-of-Line Relay Mounted on single gang I mounting type as required; wiring is 2098-9735 Plate Mounted stainless steel plate color coded 18 AWG wire leads * Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm2; 14 AWG = 2.08 mm2 S4098-0015-5 10/02 Detector Status LED Indications I LED Indication Status - Pulses approximately every 4 seconds Normal Steady On I - - Alarm LED Response to Magnetic Test * LEDIndication FollowedBy Status Action LED turns ON Alarm is initiated Normal, sensitivity is within None compensation range LED pulses quickly, More sensitive, out of normal 6 times in 3 seconds, Alarm is initiated compensation range Cleaning or other then turns ON service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensationrange Does not initiate Alarm Detectorismalfunctioning Serviceisrequired then turns ON * Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual 574-709 for further test and maintenance information. Dimensions and Reference Information 1/4" (6.4 mm) (162 mm) 4098-9832 Adapter Plate 7-1 ~- Base height 11/16" (17 mm) 4-7/8" (124 mm) 0.1 IT 1-7/8° - ;7' (48 mm) u'1fl7 LED Status Indicator (with clear lens) 4098-9601 & -9605 Dimensions Mounted on Base ALARM 0 Tlpex 4098-9830 Remote LED Indicator (not to scale) 3 S4098-0015-5 10/02 4" (102 mm) square box .4" (102 mm) octagonal box Mounting Information (Electrical boxes are supplied by others.) Electrical Box Requirements: Without ri (base 4098-9788): 4" octagonal or 4" square, 1-1/2" deep Single gang, 2" deep 3ffift relay (bases 4098-9682 and 4098-9683): 4" octagonal, 1-1/2" deep, with 1-1/2" extension ring 4" square, 1-1/2" deep, with 1-1/2' extension ring Surface mount reference 1-1/2" (38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4" (6.4 mm) maximum recess 4098-9832 Adapter Plate, reauired for mounting to surface mounted boxes and to 4" scivare flush mount boxes 4098-9682 and 4098-9683 include a relay module that mounts in base electrical box Smoke Detector Bases 4098-9788, 9682, & -9683 4098-9601, -9605 Smoke Detector Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). BSirriplex TEPG-US • 91 Technology Drive" Westminster, Massachusetts • 01441-0001 • USA S4098-0015-5 10/02 © 2002 TEPG-US (a Tyco company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:219 Page 1 of 1 CATEGORY: Photoelectric Smoke Detectors LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Mode 9601-9601TSP, -9602, -9602TSP, -9605, -9605T5P; *G5A40989601 *..9602 * 5 photoelectric type smoke detectors. Models 4098-9602, -9602TSP; and *GsA4098..9602 employs an integral 1350F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector and not intended for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed system description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with listee's listed Models 4098-9682, - 9683 or -9788 detector bases *(CSFM Listing No. 7300-0026:222) and separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation V' criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:222 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441 -0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Models 4098-9682, 4098-9683 40E le 88 nd 4098-9684 detector bases. Refer to listee's data sheet for additional deproduct description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label APPROVAL: Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 5$implex TrueAlarm® Smoke Detectors UL, ULC Listed; FM, CSFM, Duct Detector Housings with TrueAlarm Photoelectric and MEA (NYC) Approved* Detector for 2-Wire or 4-Wire Operation I1iuii* Compact air duct detector housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke detector' and features: On-board TrueAlarm sensitivity drift compensation and dirt accumulation tracking Multi-function status LED indicator Magnetic test that initiates an alarm and provides detailed diagnostic information Clear cover allowing visual inspection Test ports provide functional smoke testing access with cover in place . UL listed to Standard 268A Model availability: 4098-9685, 2-Wire standard operation 4098-9688, 2-Wire with supervised control for a single remote relay (relay included) 4098-9686, 4-Wire operation with supervised control for multiple remote relays (includes one remote relay) Mounts to rectangular ducts or round ducts Minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetically operated functional test: Initiates alarm and displays dirt accumulation status using the detector status LED Assists with maintenance priorities by categorizing detector status and identifying dirty detectors Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Red alarm LED (4098-9830) Test stations with LED(s) and keyswitch (refer to page 2 for compatibility) Relays for remote control applications * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. ULC listed models are designated with a "C' suffix such as 4098-9685C. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarm smoke detector Operation is protected by one or more of the following US Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,552,765; 5,710,541; 0383,407; D388,352; 0392,573. Duct Detector Housing, Front View H® 1]G ® H iig.H 1 g. 4098-9830 (:98) 4098-9835 Remote Alarm Indicators and Test Stations diictie Operation. Simplex® air duct smoke detector housings provide a TrueAlarm smoke detector for monitoring air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke detector mounted in the housing. These duct detector housings with smoke detectors are compatible with Simplex fire alarm control panels that provide conventional two-wire or four-wire initiating device circuits (IDCs). lrf.rI .1'TlF1 Each supports a remote red alarm LED or a remote test station with LED(s). Models with relay output provide relay coil wiring supervision that will transfer a trouble to the DC if supervision is lost. 2-Wire Model 4098-9685 provides basic smoke detection for applications that do not require a remote relay. Power is from the IDC. 2-Wire Model 4098-9688 provides a supervised relay output for connection to a single 4098-9841 relay. This model is powered from the DC and requires connection as the only device to ensure relay operation. 4-Wire Model 4098-9686 provides a supervised relay control output that can control up to 15, PAM-SD control relays. Relay supervision troubles are indicated by a yellow LED on the interface board. (Resettable 24 VDC is required, see page 4.) Remote test station 4098-9835 is available for use with this model to provide a test keyswitch, a red LED alarm indicator and a green power-on LED. S4098-0029-4 10/2003 iwf flctttnr Slcctir Duct Smoke Detector Housing with Photoelectric Detector* Model ôcription Coñipatibillty 4098-9685 2-Wire Duct Detector, standard operation No relay(s) 2-Wire Duct Detector with supervised single remote relay output; includes one 4098-9841 relay; NOTE: Must be only device on Supplied relay is required Remote LED 4098-9688 IDC for proper relay operation; (When used with the Simplex for proper operation indicator and "high 4004 or 4005 fire alarm control panel, connect to current" test stations lDCs only) per below -, 4-Wire Duct Detector with supervised multiple remote relay output, Up to 15 total PAM-SD 4098-9686 requires resettable 24 VDC fire alarm power and relay end-of-line relays (additional relays are -....._-- resistor; includes one PAM-SD relay ordered separately) LED Indicator and Remote Test Stations (Select one if required) Each assembly is on a single gang stainless steel plate, wiring is 18 AWG (0.82 mm2 ) color coded wire leads Moci'"" - Compatibility Mounting' 4098-9830 Red LED alarm indicator 4098-9685 4098-9688 Use single gang box, Test Station with keyswitch and red LED alarm indicator 4098-98349834 (turning switch to "TEST" initiates alarm for system testing) 4098-9686 3" H x 2" W x 2" D (76 mm x 51 mm 4098-9835 Test Station with keyswitch, red LED alarm indicator, and green 4098-9686 only x 51 mm) power-on LED Epoxy Encapsulated Remote Relays (wiring is 18 AWG (0.82 mm2 ) color coded wire leads) Mounting -Description T ICompatibility :i:. 4098-9841 Relay, dual Form C (1/2 A @ 120 VAC); 4098-9688 only, included with 4098-9688 Refer to pages 3 I and 4 for I one maximum I I Locate relays within I 3 ft (1 m) of device Relay, single Form C (10 A @ 120 VAC); order I additional relay I 4098-9686 only, I being controlled, per PAM-SD separately from Air Products & Controls, Ltd.; information connect up to 15 NFPA 72 one included with 4098-9686 * Each duct housing includes an internally mounted model 4098-9601 TrueAlarm photoelectric detector and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. IiiT fin .iiri II WAI Overall Duct Width (305 mm) Tube Required 2098-9796 SuggestedCut Length 1/2 in. (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2 in. (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 098-9797 2 in. (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2 in. (51 mm) longer than duct width 71" to 95" (1803 min to 2413 mm) 2098-9799 2 in. (51 mm) longer than duct width lITTYi F11111 'I 1flh!T1 I IIfl1IIUMT1 LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm Detector LED Response to Magnetic Test ** LED Indication Folloéd By Status. Action None LED turns ON Alarm is initiated Normal, sensitivity is within compensation range LED pulses quickly, More sensitive, out of normal 6 times in 3 seconds, then turns ON Alarm is initiated compensation range Cleaning or other service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required ** Testing requires placing a magnet at the designated location on the duct housing cover for 4 seconds and referring to the response from the red LED status indicator on the detector. Refer to Installation Instructions 574-776 for further test and maintenance information. S4098-0029-4 10/2003 171 mmii •!I Sampling be access hol tu e .iuui:riinryiIn- 1911111-i'mmm NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. 4 11-3/8(289mm)' - = - Magnetic test area (Exhaust tube access hole) Conduit (by others Metal I plate with dual holes 1 1 • for 314' (19 mm) conduit, plug supplied for unused hole 4098-9601 Smoke detector1 1 Yellow LED, relay control troubl mounted in base (supplied) indicator (4098-9686 only) I _____ I Winngt r k,2 apte fastening screws (4 T Mount as shown (prefeed) or with electronics area located to ansparent cover) [sketed detector are, the LEFT or UP ONLY 3-318" (86 mm) (21 mm) 1 Test ports (2) provided for measuring airflow, and for aerosol injection Sampling tube, ordered separately per duct width End View with Duct and Tubes [Duct housing 118" Round duct outlinel L (minimum diameter)] —I ) tube L48 Square duct outline1 (minimum width . •j , f• Sampling tube, keyed for proper hole alignment I with holes facing into airflow (template is I provided for proper tube installation) I Duct wall 1 tube I Remote Relays NOTE: Mount in separate electrical box within 3 ft (i m) of device being controlled per I NFPA72 1-1/4 (13 mm) 2-3/8(60 mm) [_4098-9841 (1/2 A @ 120 VAC) ) 13/16" (21 mm) I1in (38 mm) l 1-3/16" (30 mm) [PAM-SD (10 A © 120 VAC)) 3 S4098-0029-4 10/2003 liii u.Irrniiiirnii iiii* Preferred Duct Detector Locations: 1. A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. .Return 2. On the downstream side of filters to detect fires in the Air filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standard for the installation ofAir Conditioning and —supply Ventilating Systems. Air Locations to Avoid: Filter " Detector Do not locate bank OK detec Bend or other here obstruction Return 6 Duct au' (6 Duct 9 widths ,/ widths L 0.: ' minimum minimum Specifications Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Air Velocity Range (linear ft/mm) 300 to 4000 ft/min (91 to 1220 rn/mm) UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Black base with clear cover [Two-Wire Operation, Models 4098-9685 and 4098-9688 Operating Voltage 18-32 VDC, from compatible IDC 4098-9685 (no relay) Standby Current Alarm Current 100 jsA © 24 VDC 40 mA maximum © 24 VDC 4098-9688 (with single relay control) NOTE: Only one 4098-9688 per IDC Standby Current Alarm Current Relay Control Relay Rating Relay Location 2.7 mA © 24 VDC (includes relay supervision current) 40 mA maximum © 24 VDC 4098-9841 relay only, one maximum Dual Form C, 1 A @28 VDC, 1/2 A @ 120 VAC, Resistive 100 ft (30 m) maximum to relay coil, relay must be within 3 ft (1 m) of device being controlled per NFPA 72 [Four-Wire Operation, Model 4098-9686,Requires Resettable and Fused 24 VDC from Fire Alarm Power Supply Operating Voltage 18-32 VDC (24 VDC nominal) Standby Current 12 mA © 24 VDC, 32 mA © 24 VDC with 4098-9835 Test Station Alarm Current 45 mA © 24 VDC, 65 mA @ 24 VDC with 4098-9835 Test Station Add 15 mA @ 24 VDC per PAM-SD relay Supervised Remote Relay Control For use with relay PAM-SD, quantity of 15 maximum, distance of 500 ft (152 m) maximum, requires 10 1<92, 1/2 Wend-of-line resistor [PAM-SD Relay Output Ratings, Single Form C, use with Model 4098-9686 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output Relay Contacts, Resistive Ratings 7 A @28 VDC; 10 A © 120 VAC; 250 pA @ 5 VDC Location Distance 500 ft (152 m) maximum to relay coils, relays must be within 3 ft (1 m) of device being controlled per NFPA 72 Remote Alarm LED (4098-9830, -9834, & -9835) 1.7 mA, no impact to alarm current Remote Alarm LED and Test Station Distance 1 250 ft (76 m) maximum Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of Tyco international Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). .Simplex93 Tyco Safety Products Westminster - Westminster, MA - 0144 1-0001 - USA S4098-0029-4 10/2003 www.tycosafetyproducts-usa-wm.com 0 2003 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. Exhaust Detector Damper OK Exhaust Fresh air CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:241 Page 1 of I CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 0144 10001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4098-9755, *4098..97 * 098-9755TTP, 4098-9756, *4098..9756Tsp *4098..9756TTP 4098-9685 4098-9686 098-9687 and 4098-9688 photoelectric type air duct smoke detector units and o e 098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ..• . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:101 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Air Products and Controls Inc., 1749 East Highwood, Pontiac, Ml 48340 Contact: *Richard Steele (248) 332-3900 *FA)( (248) 332-8807 DESIGN: Models MR-101/C, MR-104/C, MR~ Oysuffix -201/CX, MR-204/C, MR-204/CX, PAM-1, PAM-2, PAM-2X, PAM-3, PAM IC-1 and RIC-2 relay modules. Models MR- 101/C, -201/C and -201/CX may e -R or -S. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING Listee's name, electrical rating and UL label. APPROVAL Listed as relay modules for use with separately listed compatible control units. *Rev. 05-28-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: APRIL 19, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:150 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Dr, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-854 *Fax (978) 731-8881 DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator test switch; Model 2098-9816 remote power/alarm/trouble indicator; ModeQ22L9834>remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Simplex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET Il® or lDNetTM Communicating Devices and MEA (NYC) Approved* 4090-9101 and 4090-9106, Zone Adapter Modules MAPNET II or IDNet communications** compatible Monitor ZAMs (Zone Adapter Modules) provide an addressable interface to a conventional initiating device circuit (IDC) Available for Class B or Class lDCs: 4090-9101, Class B (Style B) monitoring for 2-wire or 4-wire initiating devices, with power reset connections for 4-wire devices 4090-9106, Class A (Style D) monitoring for 2-wire initiating devices Zone device power is supplied separately (typically from fire alarm control panel) Refer to device compatibility list on page 2 Compatible with Simplex: Model Series 4010/4100/4120/4020 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 communicating device transponders (CDTs) equipped with MAPNET II communications Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4" square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 sirintii MAPNET Il/IDNet Monitor ZAMs allow a single addressable point to monitor a conventional initiating device circuit (IDC) populated with 2-wire or 4-wire initiating devices. Refer to page two for compatible devices. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 1300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact Simplex for the latest status. MAPNET II and IDNet addressable designs are protected by U.S. Patent 4,196,025. 4090 Series IDNet Relay IAM/ZAM Package (shown approximately 1/2 size) Specifications Communications MAPNET II or IDNet, 1 address per device ZAM Input Voltage 18.9 to 32 VDC (nominal 24 VDC) Supervisory = 16 mA maximum ZAM Current @ 24 VDC Alarm =72 mA maximum (actual current is determined by total device requirements) 4090-9101 ZAM, Zone 3.3 k, 1 W Supervision Resistor Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire Up to 2500 ft ( 162 m) from fire alarm control panel Up to 10,000 ft ( 3048 m) total wiring MAPNET II or IDNet Wiring distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 41/8"Hx41/8°Wx13/8°D (105 mm x 105 mm x 35 mm) Housing Material Black thermoplastic Mounting Plate Material Sheet metal, galvanized Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RI-I at 100° F (38° C) © 2000 Simplex Time Recorder Co. All rights reserved. S4090-0003 8/00 ITYr1TLr1rT1 ZAM Module i Model Number Description 9lol Zone adapter module, for Class B monitoring of 2-wire or 4-wire initiating devices, with power reset connections for 4-wire devices 4090-9106 1 Zone adapter module for Class A monitoring of 2-wire initiating devices Optional Trim Plates and Mounting Bracket 4090-9801 For semi-flush mounted box Trim plate with LED viewing window, includes mounting screws 4090-9802 For surface mounted box Description L • Model Number :Compatible xhi1 Bases um 0 Direct connect photoelectric smoke detector 2098-9209 4098-9401 No base 4098-9402 required 20 4098-9403 4098-9404 Electronic heat detectors 4098-9612 4098-9788 4098-9613 20 4098-9614 4098-9684 4098-9615 4098-9683 1 4098-9601 4098-9788 20 Photoelectric smoke detectors 4098-9602 4098-9683 1 4098-9605 4098-9788 20 Ionization smoke detector 4098-9603 4098-9683 1 Duct detector housing with 4098-9601 detector 4098-9685 N.A. 20 Reference for Existing Equipment 2098-9201 2098-9211 20 2098-9202 Smoke detectors 2098-9203 2098-9576 2098-9637 1 4098-9407 Electronic heat detectors 4098-9408 2098-9211 20 .4098-9409 4098-9410 NOTES: Four-wire detector operation is compatible with conventional listed contact closure initiating devices. Four-wire detectors require detector voltage to be connected to resettable power terminals. Refer to installation instructions 574-183, and field wiring diagram 842-073 for additional information. Contact Simplex for additional compatible devices. Simplex Time Recorder Co. 2 S4090-0003 8/00 ZAM Mounting Information 11 Address setting under resealable label 4(102mm) square box, 2 1/8 \\ (54 mm) minimum depth, RACO 232 or equal (supplied by others) 4090-9101/9106 ZAM Double gang blank cover plate and mounting screws, for use when LED is not required to externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate 49/16" (116 mm) © © © © Light pipe for LED viewing ('109 m) © © © © —4 9/16" (116 mm) ii 45/16" (109 mm) PP 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED Simplex Time Recorder Co. 3 S4090-0003 8/00 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:223 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattem (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4090-9001, *..9001TsP *..9001uP and *..9051 Supervised lAM Monitor Module; 4090-9002, *..9002TsP and *..9002uP lAM odule; 4090-9106, *..9106TSp and 9I06TTP Class "A" LAM Initiating Module, 090-9101 -9I01TSP, and *..91 01 UP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 09-25-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ... . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager £®Simplex TrueAlert® Notification Appliances UL, ULC Listed; FM, CSFM, SmartSyncTm Control Module and and MEA (NYC) Approved* Strobe Synchronization Modules I1ui*i Convert conventional Notification Appliance Circuits (NACs) into SmartSync circuits or synchronized strobe circuits: SmartSync Control Modules combine separate horn and strobe NAC inputs into a 2-wire control that can silence horns while maintaining synchronized strobe operation** Synchronized Flash Modules provide a 2-wire synchronized strobe output that also operates compatible 24 VDC conventional reverse polarity notification appliances* * SmartSync Control Module (SCM) provides two-wire control to separately activate horns and strobes: Operation allows "on-until-silenced" and "on-until-reset" on the same two-wire pair while maintaining supervision continuity SmartSync horns sound as Temporal or March Time pattern, or continuous, controlled separately from strobes on the same circuit Strbes on the same circuit operate at a synchronized 1 Hz flash rate Output is either Class B or Class A Conventional strobe synchronization models: Encapsulated package with color coded wire leads provides 1 Hz strobe synchronization and maintains supervision continuity Conventional horns and other DC appliances operate on the same 2-wire circuit Models are available with Class B or Class A output Small size allows convenient mounting UL listed to Standard 1971 * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:198 and 7125-0026:235 for allowable values and/or conditions concerning material presented in this document. It is Subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. 4905-9938 SmartSync Control Module (SCM), Shown Approximately 1/2 Size 4905-9922, Class A Synchronized Flash Module, Shown Approximately 1/2 Size Model 4905-9938 SCM (SmartSync Control Module) converts two conventional NAC inputs into a SmartSync two-wire NAC output. One NAC can be programmed to operate as "on-until-silenced" and would be designated as the horn control (non-coded, on continuously during alarm). A second NAC would be programmed to provide "on-until-reset" operation and would be for the visible appliance (strobe) control (also non-coded, on continuously during alarm). Power is supplied by the strobe control NAC. Selectable Horn output and Synchronized Strobes. In addition to operating the strobe and the horn independently, the SCM can be switch selected to operate the horns as temporal coded, march time coded (60 beats/minute), or on continuously. Strobes are activated with 1 Hz synchronized flashes. S4905-0003-2 9/2004 Multi-Sync Mode. Up to eight SCMs can be interconnected to synchronize system notification. Interconnected SCMs are supervised for proper circuit connection. The horn input NAC powers the Multi-Sync function. Isolated NAC Inputs. Both NAC inputs are isolated from each other and can be supplied from different control panels. Class B (Style Y) and Class A (Style Z) output operation are both supported. Earth fault detection is provided by the strobe control NAC during supervision mode. UT .1 FI irmr Model 4905-9914 and 4905-9922 add the required control to activate Simplex synchronized strobes for NACs that do not provide that control. Conventional horns or other compatible 24 VDC notification appliances on the same circuit ignore strobe synchronization and operate when the NAC is in alarm. For additional information refer to Installation Instructions 579-232. For additional information refer to Installation Instructions 574-719. Product Selection f d Description, PaceDetaIIs 4905-9938 SmartSync Control Module, Class A Dimensions: 4" x 4-1/8" x 1-1/4" D (102 mm x 105 mm x 32 mm); - or Class B output mounts in 4" (102 mm) square box 4905-9914) Class B Synchronized Flash Module Dimensions: 1-3/8" x 2-7/16" x 13/16" D (35 mm x 62 mm x 20 mm); epoxy encapsulated with 8" (203 mm) in/out 18 AWG (0.82 mm2) wire 4905-9922 1 Class A Synchronized Flash Module leads; rated for 2 A NAC; requires 5 mA for power Specifications General Specifications Temperature Range 1 32* to 122° F (0° to 50° C) Humidity Range 1 10% to 93%, non-condensing at 100° F (38° C) 4905-9938 SmartSync NAC Modules (for use with SmartSync compatible appliances) Input Voltage Range 16 VDC to 33 VDC; with a maximum ripple of 2 V peak-to-peak Output Ratings 2 A maximum; can be wired as Class A or Class B Up to 35 maximum SmartSync appliances with strobes Up to 40 maximum SmartSync horn-only appliances Strobe Control NAC Input Current Output NAC current, plus 30 mA @ 24 VDC for SCM operating power Horn Control NAC Current 4 mA @ 24 VDC Class A Operation Mounting Requirement Mount SCM within 20 ft (6 rn) of control panel, use metal conduit 4905-9914 & 4905-9922 Synchronization Modules Input Voltage Range 116 VDC to 33 VDC 2 A maximum output; requires 5 mA for power Output Ratings Up to 35 maximum strobes per synchronized circuit Mount in control panel or separate 4" (51 mm) square electrical box, 1-1/2" (38 mm) minimum depth S4905-0003-2 9/2004 NAG Capability Reference RtrolPanels/NAC Source Available Output - Module Required/Function 4010 Series Fire Alarm Control Class A or Class B Strobe Synchronization NA Class B SmartSync Operation 4905-9938 for Class A SmartSync operation Panels 4006, 4008, and 4100U Series Class A or Class B Strobe Synchronization NA Fire Alarm Control Panels Class A or Class B SmartSync operation NA Model Series 4003, 4004, 4005, Conventional reverse polarity NACs, 4905-9914 for Class B synchronized strobes 4100, 4120, 4020, 4001, & 4002 additional modules are required to control Control Panels; 2190 Series synchronized strobes and/or SmartSync 4905-9922 for Class A synchronized strobes Signal ZAMs; 4009 Series Conventional NAC Extenders appliances 4905-9938 for SmartSync control 4009 IDNet NAC Extenders Class A or B Strobe Synchronization NA Class B SmartSync Operation 4905-9938 for Class A SmartSync operation Module Reference Module.. Description 4905-9938 SmartSync Control Module, provides Class A or Class B SmartSync operation 4905-9914 Class B Strobe Synchronization Module 4905-9922 Class A Strobe Synchronization Module Compatible Appliance Reference [Appliance TypiTi Model* Module Reference 4905-9938 Horn Wall mount; selectable for SmartSync operation 4901-9820 Strobes Wall mount; synchronized; also SmartSync compatible 4904-9331 4904-9342 4906-9101 4905-9914 4905-9922 4905-9938 4904-9332 4904-9343 4906-9103 4904-9333 4904-9344 Ceiling mount; selectable for synchronized flash; also SmartSync compatible 4904-9183 4904-9345 49069102 4904-9184 4904-9346 4906-9104 4904-9185 AN Horn/Strobe Wall mount; horn and strobe can be wired separately (4-wire); strobes are selectable for synchronized flash 4903-9425 4903-9427 4903-9432 4905-9914 4905-9922 4903-9426 4903-9431 4903-9433 Wall mount; SmartSync operation only (2-wire) 4903-9331 4903-9342 4906-9127 4905-9938 4903-9332 4903-9343 4906-9129 4903-9333 4903-9344 Ceiling mount; SmartSync operation only (2-wire) 4906-9128 4906-9130 Rectangular case wall mount; horn and strobe can be wired separately (4-wire); strobes are selectable for synchronized flash 4903-9252 4903-9257 4903-9256 4905-9914 4905-9922 4903-9253 4903-9258 4903-9254 4903-9255 Ii SN Speaker/Strobe Wall mount; strobes are selectable for synchronized flash 4903-9356 4903-9359 4906-9151 4905-9914 4905-9922 4903-9357 4903-9360 4906-9153 4903-9358 ___________ 4903-9361 Ceiling mount; strobes are selectable for synchronized flash 4903-9196 4903-9198 4906-9154 4903-9197 Rectangular case wall mount; strobes are selectable for synchronized flash 4903-9148 4903-9150H 4903-9194 4903-9149 4903-9153 4903-9195 __________ 4903-9150 4903-9193 *Bolded PlDs are Multi-Candela products. ** Modules listed are required if control panel NAC or NAC extender does not provide either synchronized strobe output or SmartSync control output as required for proper appliance operation. S4905-0003-2 9/2004 IurnIrIrIf]1]Ir.( 4905-9938 SmartSync C cj Control Module (SCM)\ I (T 0 0 0 0 0 flAiL 0 \\dIrL)0 Mounting Box (by others): Square box, 4" (102 mm), required depth depends on total conductor requirements Minimum depth = 2-1/8" (54 mm), RACO 232 or equal 4" square cover plate, RACO 752 or equal Extended depth (for maximum (by others) conductors), add 1-1/2" (38 mm) extension ring, RACO 201 or equal Tyco, Simplex, the Simplex logo, TrueAlert, and SmartSync are trademarks of Tyco International Services AG or its affiliates in the US. and/or other countries. .Simplex93 Tyco Safety Products Westminster• Westminster, MA 0144 1-0001 • USA S4905-0003-2 9/2004 www.tycosafetyproducts-usa-wm.com 02004 Tyco Safely Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision dale and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:248 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex Time Recorder, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul D. Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4904-9174 through -9185 strobes, Models 4904-9345, -9346 synchronized strobes, and *Model 4905-9914 r4905-9922 synchronized modules. Synchronized modules are required for sync ronizing strobe lights if the interconnected control unit cannot provide synchronization itself. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24 VDC Candela: -9176, -9177, -9178, -9183, -9345: 15cd, 1Hz. -9174, -9179, -9180, -9184, -9346: 30cd, 1Hz. -9175, -9181, -9182, -9185: 110cd, 1Hz. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as strobes for use with separately listed electrically compatible fire alarm control units. For indoor use only. All models are for wall mount except for Models -9183, -9184,-9185,-9345 and -9346 are for wall/ceiling mount. *Rev. 02-18-2003 JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager BSimplex TrueAlert® Multi-Candela Notification Appliances UL, UL Listed; Visible Notification Appliances with Synchronized Flash; FM Approved* Non-Addressable, SmartSyncTM Operation Compatible I1ii* Visible only (VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: . UL listed to Standard 1971 intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: 4010 Series and 4100U Series fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control** 4009 IDNetTM NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes * This product was not approved by CSFM or MEA (NYC) as of document revision date. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. ----------------------- FIRE Wall Mount Strobes t± IIJIW V1K 4tM!01 J Ceiling Mount Strobes Descrintinn Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. lntcnsitv Scictir During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Strobe Annlicitinn Rcfrne Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S4906-0001 4/2004 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). Fr.T1Iieiiit.*i Class B SmartSync two-wire control is available from: 41001J and 4010 Fire Alarm Control Panels; 4010 panels require operating software Revision 2.X or higher (refer to data sheet S4010-0001 for details; refer to data sheet S4100-0031 for basic 4100U information) 4009 IDNet NAC Extender, models 4009-9201 and 4009-9301 (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938, converts separate conventional horn and strobe NAC inputs into a SmartSync NAC output; up to eight SCMs can be synchronized to each other Class A SmartSync two-wire control is available from 4100U NACs and from the 4905-9938 SCM. Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. u OT-RIM rtr1 Multi-Candela Visible Notification Appliances (Strobes) :M0deI Mounting Housing Color FIRE Lettering - 4906-9101 I I Red I White Wall I 4906-9103 J White Red 4906-9102 I Red White Ceiling .4906-9 White Red Wall Mount Strobe Adapters Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; SmartSync two-wire control compatible TMdeI -- Description - Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" D 4905-9940 White deep surface mounted boxes (136 mm 133 mmx4l mm) Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 (200mmx130mrnx70mm) Ceiling Mount Strobe Adapter iv!Oaei uescrlption 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to handy box; not needed when using 4905-9926 guard Synchronization Modules (refer to data sheet S4905-0003 for additional information) 4-7/8" x 3-1/8" x 0.060" D (124 mrnx79 mm x 1.5) - - Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, 4905-9922 Class A requires 10 mA for power 1-3/8" x 2-7/16" x 13/16" (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in I 4" x 4-1/8" x 1-1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Dimensions 4905-9992 Red cover with white "FIRE" lettering For Wall mount strobes 5-1/8" H x 5" W x 1-1/2" D 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) 49059961* Wall mount I 6-1/16" H x 6-1/16" W x 3-1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) 4905-9926" semi-flush or surface mounted boxes 6-1/8" x 4-3/8" x 2-7/8" deep Ceiling mount (156 mmxlii mmx73 mm) * UL listed by Space Age Electronics Inc 2 S4906-0001 4/2004 Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others Wiring access hole Wiring terminals \ -- \\ Mounting Holes: - Double e gang Transparent housing and lens assembly Intensity selection 75 plug, accessible only [ I] [IND[ from rear of housing; factory setting is 15 Cd Removable cover Strobe intensity (tool required) viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly above bottom outline of compatible boxes \4 box NFPA72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor Jr ________ 1T Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 VDC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 c 30cd .. 75 c 110cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 55 mA 85 mA 169 mA 226 mA I 4imA 63 164 mA_ Housing Dimensions (with lens) 4-3/4" Lx 2-5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 Cd 30 Cd 75 cd 110 Cd 75 mA 125 mA 4 1 233 mA 316 mA Reference RMS Currents 18 VDC átother,voltages 24VDC 64 mA 102 mA 199 mA 266 mA 49 mA 76 mA 146mA 195 mA NOTES: 'Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting Ceiling Mount Strobe Installation Reference Single gang box (Wiremold V5744S) 2-1/4' (57 mm) deep, supplied by others Handy box, 1-1/2" (38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2 (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, required for 000 surface mount with handy box unless using the 4905-9926 wire guard FT Ceiling mount strobe Optional 4905-9926 wire guard U VU ' with mounting plate - - - - - Strobe intensity H viewing slot I Intensity selection plug, - accessible only from rear of lens' housing factory setting is 15 c Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt 145 Box fl 11flJl IMom 0 LLD ni o o r 4905-9931 Adapter Plate" 0 4905-9961 Optional Wire Guard (shown here for reference only, 4905-9931 Adapter Plate) can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4(102mm) square box profile, 1-1/2" (38 mm) deep Optional 4905-9961 Wire Guard - 7 Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco. Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSync are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). .Simplex Tyco Safety Products Westminster• Westminster, MA '01441-0001 'USA S4906-0001 4/2004 93 www.tycosafetyproducts-usa-wm.com 02004 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:316 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable s lights. Models 4906-9101 and —9103 are for wall mount. Models 4906-9102 and 9104 re for ceiling mount. Synchronizing modules are required for synchronizing stro e lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager SirnplexGrinnell LP 9855 Carroll Canyon Road tqca IF/re & /SimplexGrinnefi San Diego, cA 92131 T&e: (858) 740-0100 /Fire Fax: (858) 740-0156 www.simplexgrinnell.com Contractor License # 802591 * * * Business Information * * * SIMPLEX GRThNELL L P 6952 PRESTON AVE STE A LIVERMORE, CA 94550 Business Phone Number: (925) 273-0100 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2005 * * * License Status * * * This license is current and active. All information below should be reviewed. * * * Classifications * * * Clasi ] Description tcio IIELECTRICAL 16 * * * Certifications * * * Description I F ASBESTOS - (for bidding purposes only) * * * Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 81880913 in the amount of $10,000 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2004 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL(1): This license filed Bond of Qualifying Individual number 81880915 for RONALD GILBERT MAYLE in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 BOND OF QUALIFYING INDIVIDUAL(2): This license filed Bond of Qualifying Individual number 81880914 for FRANKLIN MICHAEL BROWN in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 * * * Workers Compensation Information * * * This license has workers compensation insurance with the AMERICAN HOME ASSURANCE COMPANY 8/9/2005 REV.#: 0 PROJECT #: 480-402025-01 SimplexGrinnell LP 9855 Carroll Canyon Road tqca / Fire & / SimplexGrinneII San Diego, CA 92131 Tele: (858) 740-0100 Security / Fax: (858) 740-0156 www.simplexgrinnell.com Policy Number: RMWC5898786 Effective Date: 10/01/2004 Expire Date: 10/01/2005 SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. 8/9/2005 REV.#: 0 PROJECT #: 480-402025-01