Loading...
HomeMy WebLinkAbout2508 EL CAMINO REAL; ; FS030006; Permit11/21/24, 9:44AM FS030006 Permit Data City of Carlsbad Fixed Systems Permit 2508 EL CAM INO Job Address: REAL Permit Type: FIXSYS Parcel No: Lot #: 0 Reference No.: PC #: Project Title: MEXICAN VIEJO Permit No: FS030006 Status: ISSUED Applied 2/28/2003 Approved: 3/11/2003 Issued: 3/11/2003 Inspector: Applicant: Owner: 1 Fees ($) Add'l Fees ($) Total ($) Balance ($) 100 0 100 0 about:blank 1/1 ccy%, Chapter 3 - System Design CHAPTER III SYSTEM DESIGN GENERAL This section will cover the proper design of the Protex Series II Restaurant Fire SuppressiQn System. It is divided into four (4) sections: Cylinder Sizing Nozzle Coverage and Placement Piping Limitations Detector Requirements Each of these sections must be completed before attempting any installation. SYSTEM CYLINDER SIZING Each of the nozzles in the section, "Nozzle Coverage and Placement" has its own flow point value. Each of the three different agent tanks can support a maximum number of flowpoints, based on the volume of the pipe used. Select the system tank(s) by calculating the total number of flow points associated with the appliances(s), plenum, and ducts, plus the total piping volume. ' CAUTION Do not exceed the maximum number of flowpoints as shown on the Tank Chart, page 46. If the number of flow points or the pipe volume required exceeds the amounts shown, additional tank(s) or changes in piping design are required. NOZZLE COVERAGE AND PLACEMENT This section will provide guidelines for determining nozzle type, positioning, and quantity for duct, plenum, and appliance protection. A. DUCT PROTECTION It is not required that the fan be shut down or the exhaust duct be dampered for the system to operate properly. Each nozzle is approved to protect exhaust ducts of unlimited length. Duct protection requires that a nozzle by positioned to dis- charge up, into the duct. The nozzle is a Part No. NL2D. The NL2D duct nozzle is a two (2) flow nozzle. A single 6 IN. INTO DUCT 2D NO LE Figure 3-1 NL2D nozzle is capable of protecting square or rectangular duct with a maximum of 100 in. perimeter, with the longest side being a maximum of 34 in. It can also protect a round duct with a maximum diameter of 31 7/8 in. Two (2)NL2D duct nozzles can protect a square or rec- tangular duct with a maximum of 150 in. perimeter, with the longest side being a maximum of 51 in. They can also pro- tect a round duct with a maximum diameter of 47 1/2 in. When two (2) NL2D duct nozzles are used to protect a single duct, the cross sectional area of the duct must be divided into two equal symmetrical areas. The nozzle must then be installed on the centerline of the area it protects and aimed directly into the duct opening. The nozzle(s) must be installed on the centerline of the duct, with the tip located 0 to 6 in. into the opening, and aimed directly into the duct opening. See Figure 3-1. TRANSITION DUCTS The protection of non-standard ducts should be reviewed by the authority having jurisdiction. Protex Series II recommends that transition ducts be protected as follows: A. TRANSITION DUCTS - LARGER TO SMALLER In cases where the duct/plenum interface opening is larger than the final exhaust duct, measure the perimeter/diameter UL XXXX January 15, 2002 11 Part # PMAN2 rev 0 V-BANK Chapter 3 - System design B. PLENUM PROTECTION The NL1H nozzle is a one (1) flow nozzle used for plenum protection. A single NL1H nozzle can protect a plenum (with single or V-bank filters) 10 ft. long by 4 ft. wide. Dividing the length into sections equal to or less than 10 ft. in length and positioning a nozzle at the start of each section can be done to protect longer plenums. On V-bank plenums, the nozzle(s) must be located at the center of the V-bank width, 1/3 of the vertical height of the 'filters. On single filter bank plenums, the nozzle must be located 2 in. from the back edge of the filter, 1/3 down from the vertical height. For either application, the nozzle must be located within 6 in. of the end of the plenum (or module) and aimed directly down the length of the plenum. See Fig. 3-2. I SINGLE BANK Figure 3-2. a UL XXXX January 15, 2002 13 ?act # PMAN2 rev 0 Chapter 3 - System Design C. APPLIANCE PROTECTION Note: When protecting appliances which are larger than sin- gle nozzle coverage, multiple nozzles can be used. Larger appliances can be divided into several modules, each equal to or smaller than single nozzle coverage. Exception: Fryers must not exceed a maximum of 864 sq. in. For modularizing fryers, refer to "Protecting Large Fryers by Dividing Their Area Into Modules," page 22. Design Index Chart and Nozzle Coverage Summary Sheet Area/ Mm. Max Nozzle Flow Width Length Height Height Appliance Mount Figure Type Points (in) (in2lin) (in) (in) Deep Fat Fryer Vat H 3-31 NL2H 2 19-.1/2 19 24 48 Deep Fat Fryer - Vat L 3-4 NL2L 2 19-1/2 19 13 24 Deep Fat Fryer wl drip board H 3-5 NL2H 2 24 48 Deep Fat Fryer wl drip board L 3-6 NL2L 2 13 24 Tilt Skillet/Braising-Pan. H 377 NL2H 2 27-3/4 500 24 48 Tilt Skillet/Braising Pan L 3-8 NL2L 2 27-3/4 500 13 24 Four Burner Range 3 9 NL2L 2 28 28 34 48 Two Burner Range H 3-10 NL1H 1 12 28 40 50 two. Burner Range L 311 NL1L 1 12 28 13 213-1/2 Small Wok H 3-12 NL1H 1 24" dia. 6' depth 24 48 Small Wok L .3-13 NL1L 1 24 dia 6 depth 13 24 Large Wok H 3-14 NL2H 2 30" dia. 8" depth 24 48 Large Wok L 3-15 NL2L 2 30 dia 8 depth 13 24 Small Griddle H 3-16 NL1H 1 36 1080 24 48 Small Griddle L &17 NL1L 1 36 1080 10 24 Large Griddle H 3-18 NL2H 2 48 1440 24 48 Large Griddle L 3 19 NL2L 2 48 1440 13 24 Gas Radiant Char-Broiler H 3-20 NL1 H 1 26 624 24 48 Gas Radiant Char Broiler L 3 21 NL1L 1 26 624 13 24 Large Gas Radiant Char-Broiler H 3-22 NL2H 2 36 864 36 48 Large Gas Radiant Char Broiler L 323 NL2L 2 36 864 13 36 Lava Rock Char-Broiler H 3-24 NL2L 2 26 624 24 35 Lava Rock Char Broiler L 325 NL2L 2 26 624 15 24 Natural Charcoal Char-Broiler H 3-26 NL1H 1 24 480 24 35 (max. fuel depth 6") Natural Charcoal Char Broiler L 327 NL1L 1 24 480 15 24 Mesquite Char-Broiler H 3-28 NL1 H 1 24 480 24 35 (max. fuel depth 6') Mesquite Char Broiler L 329 NL1L 1 24 480 15 24 Upright/Salamander Broiler 3-30 NL1L 1 36W 28 D Front Edge above the chain Chain Broiler (Internal Chamber) .3-31 -Nu L1 1 27W 38 D Fr ont Edge 1-3.1 above the chain ULXXXX January 15, 2002 15 Part # PMAN2 rev 0 * Chapter 3 - System Design Fryers with Drip Board (High Mount Nozzle) Compulsory Nozzle NL2H Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection Condition 1 Deep Vat Cooking Area 324 square inches with a maximum longest side dimension of 18 inches. (excludes drip board) Overall Cooking Area 500 square inches with a maximum longest side dimension of 27-3/4 inches. (includes drip board) Condition 2 Deep Vat Cooking Area 371 square inches with a maximum longest side dimension of 19-1/2 inches. (excludes drip board) Overall Cooking Area 495 square inches with a maximum longest side dimension of 25-3/8 inches. (includes drip board) Nozzle Location Anywhere over the protected area. Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming Aimed at the center of the cooking area. Graphic Representation See Figure 3-5 L bo1e must be located anywhere within the shaded area and aimed at the center of the protected zone OVERALL COOKING AREA LONGEST SIDE DIMENSION 27-3I4 500 SQUARE INCHES MAXIMUM COOKING AREA - I OVERALL COOKING AREA LONGEST SIDE DIMENSION 495 SQUARE INCHES MAXIMUM COOKING AREA 324 SQUARJ INCHES MAXIMUM DEEP VAT AREA Part # PMAN2 rev 0 371 SQUA INCHES MAXIMUM DEEP VAT AREA 18" LONGEST SIDE DRIPBO -. DIMENSION (DEEP VAT) Condition 1 Figure 3-5 18 Condition 2 law, LONGEST SIDE DIMENSION (DEEP VAT) UL XXXX January 15, 2002 Chapter 3 - System Design S J Four Burner Range Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) - Number of Nozzles Required 1 (One) Maximum Area of Protection 28 inches x 28 inches Nozzle Location On both the front to back centerline and side to side centerline. Nozzle Height 34 inches to 48 inches above the cooking surface. Nozzle Aiming Directly down. Graphic Representation See figure 3-9 Nozzle must be located anywhere within the shaded area on the intseötionof the center lines and aimed at the center of the protected zone. Figure 3-9 Part # PMAN2 rev 0 23 UL XXXX January 15, 2002 Chapter 3 7 $ystem Design Small Griddle (High Mount Nozzle) Compulsory Nozzle NL1H Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 1080 square inches with a longest side dimension of 36 inches Nozzle Location Above any corner of the protected area. Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming At a point 12 inches in and 12 inches over from the corner below the nozzle. Graphic Representation See figure 3-16 Ni zz1e must be located anywhere within the shaded area and aimed at the center of the protected zoi I - L /1 NOZZLE CAN BE .----. MOUNTED ABOVE A ':-- ANY CORNER 1080 SQUARE INCHES MAXIMUM COOKING AREA Figure 3-16 Part # PMAN2 rev 0 30 UL XXXX January 15, 2002 Chapte 3 - System Design Large Griddle (High Mount Nozzle) Compulsory Nozzle NL2H Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 1440 square inches with a longest side dimension of 48 inches Nozzle Location Above any corner of the protected area. Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming At a point 12 inches in and 12 inches over from the corner below the nozzle. Graphic Representation See figure 3-18 [Nozzle must be located anywhere within the shaded area and aimed at the center of the protecte zone.1 <•1- ________ :. T I NOZZLE CAN BE MOUNTED ABOVE A ANY CORNER \ 1440 SQUARE INCHES MAXIMUM COOKING AREA Figure 3-18 Part # PMAN2 rev 0 32 UL XXXX January 15, 2002