HomeMy WebLinkAbout2525 EL CAMINO REAL; ; AS070304; Permit11/21/24, 9:35 AM AS070304 Permit Data City of Carlsbad Sprinkler Permit 2525 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 1563020900 Lot #: 0 Reference No.: Permit No: AS070304 Status: ISSUED Applied 12/28/2007 Approved: 12/28/2007 Issued: 12/28/2007 PC #: Inspector: Project Title: MOTHERHOOD MATERNITY, STE 131B TI FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: BRADSHAW ENGINEERING CORP 8645 ARGENT ST SANTEE CA 619-448-4300 :IA!AA II] PLAZA CAM INO REAL C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Fees ($) lAdd'I Fees ($) Total ($) Balance($) 130 0 130 0 about:blank 1/1 A The Concealer® A Concealed Sprinkler With %" (13mm) or 1%" (38mm) Adjustment Features Push-on/Thread-off cover plate assembly attachment with ½" (13mm) adjustment. Does not require clips or springs. 11/2" (38mm) Total adjustment provided by adjustable inlet versions. Adjustable inlet version available with either 1" NPT ale or female threads eliminating costly reducing coupling. Smooth aesthetic ceiling profile. Available in white or other color painted or brass, chrome, or black plated finishes. Ordinary and intermediate temperature ratings. Multiple orifices for design flexibility. Approvals & Listings Underwriters Laboratories Inc. (UL) Underwriters Laboratories of Canada. (ULC) 3.N.Y.C. BS&A No. 587-75-SA. Note: Approvals are for light and ordinary hazard, except for small orifice sprinklers which are limited to light hazard occupancies. The cup and skirt are fabricated from plated steel and are intended for interior non corrosive applications. U.S. Patent No. 4,880,063. ppuicaiion The Reliable Model 04 Concealer® is the most versatile concealed sprinkler available. It provides the best form of fire pro- tection while offering an attractive appearance and 1/21? (13mm) of cover adjustment for ease of instal- -: - lation. The adjustable 1" NPT inlet versions have iy" (38mm) of total adjustment and also eliminates the need for a reducing cou- pling. The small diameter Push-on/Thread-off cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an automatic sprinkler system. Bulletin 121 Rev.! Model G4 Concealed FD Automatic Sprinkler 73 Do The Concealer® is designed for use where aesthetic ap- pearance is important. Offices, hospitals, motels and res- taurants are but a few of the applications where it can be used. It is available in different orifice sizes allowing the de- signer to optimize system performance, thereby achieving a most efficient installation. The Concealer® can eliminate the need for precise cutting of drop nipples. The Push-on/Thread-off cover plate assem- bly can be adjusted without tools so it mates accurately with the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Product Description The Reliable Model 04 Concealer® uses the proven Model 0 fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The Push-on/Thread-off cover plate and sprinkler cup assem- blies are held tight by a flexible tooth engagement to the threaded cup. This threaded engagement provides 1/2'? (13mm) of cover adjustment. The flat cover plate is attached to the skirt using an ordinary temperature classification sol- der. This results in a strong cover plate assembly with an or- dinary temperature rating, and an intermediate temperature sprinkler which can be installed in 150°F (66°C) environ- ments. When the ceiling temperature rises, the solder hold- ing the cover plate to the skirt melts, the flat cover plate released thus exposing the sprinkler inside to the rising am- bient temperature. The subsequent fusing of the sprinkler element opens the waterway and causes the deflector to drop into position to distribute the discharging water. Any secure engagement of the threads between the cover plate and cup will assure that the drop—down deflector is properly located below the ceil- ing when a sprinkler operates. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Installation Do not install The Concealers in ceilings which have positive pressure in the space in the space above. After a 2/ inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model G4 Wrench. The wrench has drive tangs which insert into cup slots. When installing a sprin- kler the wrench is first positioned into the sprinkler/cup assembly until the wrench tangs engage drive slots in the top of the cup (there are two sets of mating drive slots in the cup). The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY The adjustable inlet versions are similar to the standard Model G4 except that an addition 1" (25mm) of adjustment is provided by means of a telescoping inlet section that threads in or out of a stationary coupling reducer (either 1 male or 1 female) as shown in Fig. 2 or Fig. 3. These sprinklers must be installed before the ceiling is in place, by wrenching on only the coupling reducer Temperature Ratings Classification Sprinkler Cover Plate Max. Ambient Temp. Ordinary 135°F/57°C 135°F157°C 100°F/38°c Ordinary 165°F174°c 135°F/57°C 100°F/38°C Ordinary 165°F/74°C 165°F/74°c 100°F/38°C Intermediate I 212'F/1 00'C 165°F/74°C 150°F/66°C Installation Data hex flats. After the ceiling has been installed with holes for the sprinkler, each telescoping inlet section is to be adjusted with the G4 Wrench. Install the push-on/thread-off cover plate assembly over the sprinkler by holding and pressing it straight up into the cup. Final adjustment of each cover assembly is made by hand turning it clockwise until it is tight against the ceiling. Maintenance The Model G4 Concealer should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick re- placement of damaged or operated sprinklers. Prior to installa- tion, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Cover Plate Finishes (1) Ordering Information Sprinkler Model Temperature Rating Nominal Orifice Flat Cover Plate Finish Inlet Type Note: Unless otherwise specified, the 165°F (74°C) sprinkler will be provided with the 165°F (74°C) cover. Standard Finishes Bronze Chrome Plated White Special Application Finishes Black Plated Bright Brass Off White Black Paint Sprinkler Inlet Total Adjustment Nominal Orifice Nominal actnr Thread Approvals Sprinkler I Identification Number (SIN) US Metric Non:-Adjustable X"(l3mm) X"(l5rrrn) 5.6 80 )"NPT(R½) 1,2,3 R2115 Non--Adjustable X"(l3mm) 7/6 (llrrm) 4.2 80 X" NPT (R1/2) 1,2,3 R2113 Non-Adjustable X"(i 3mm) " (lOnTfl) 2.8 40 " NPT (R1/2) 1,2,3 R2111 Adj.jtabIe iX"(38mm) X"(lEmm) 5.6 80 1"NPT Male rFemale 1,2,3 R2118 Adjustable 1)"(38mm) 7X6"(11111i) 4.2 80 1"NPT Male cjrFemale 1,2,3 R2113 Adjustable 1)"(38mm) 3"(1T1T) 2.8 I 40 1"NPT MaiecFemale 1,2,3 R2112 11 Other colors and finishes are available. Consult factory for details Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Installation Wrench Model G4 Sprinkler Wrench ,.. ,r( G 'I1l1l) I /lili ' I I -11TIf 1, -MTf f—1 , -. Hg. 3- 1" NI-'I I-emaie--/Acljustaole iniet Fig. 1 -X" (R)/2) NPT Non-Adjustable Inlet Fig. 2- 1" NPT Male-Adjustable Inlet The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Office (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices Revision lines indicate updated or new data. www.reliabiesprinlder.com Internet Address EG. Printed in USA 06/02 PIN 9999970014 AS0034 Bulletin hiM The Most Compact Attractive and Easily Installed Sprinkler Ever Designed! Features 11/2" (38mm) Total adjustment provided by adjustable inlet versions. ½" (13mm) Total adjustment provided by economical standard inlet version. Adjustable inlet version available with either 1" NPT male or female threads eliminating costly reducing coupling. Small diameter escutcheon. Available in brass, chrome orwhitefin ish. Multiple orifice sizesfordesignflexi bility. Listed by Underwriters Laboratories Inc. & Underwriters' Laboratories of Canada. Approved by Factory Mutual Research Corp. & Loss Prevention Council, NYC BS&A No., 587-75-SA. Product Description Today's modern buildings demand that a sprin kler not only provide the best fire protection but also achieve an attractive appearance. Reliable's Model G Recessed Sprinkler meets both criteria. It combines the fire fighting ca pa bil ityof aproven sprin klerwith thesmall estpracti ca- ble recessing unit. Its small profile does not disrupt the overhead aesthetics, and yet one vertical glance upward gives a visual assurance of the finest in fire protection, an automatic sprinkler system. The Model G Recessed Sprinkler's threaded two-piece construction makes initial field installation a very easy task. it allows ceilings panels to be removed without shutting down the fire protection thus facilitating maintenance of above ceiling services. The adjustable one inch NPT in let versions have one and one half inches of adjustment which eliminates both the normally re- quired reducing coupling and the need to accurately cut drop nip pies. This sprin klercan bead justed at terthe ceil- ing is in place and even while the system is pressurized eliminating the final corrections to pipe hangers or ceil- ings that might otherwise be required. The Reliable Model G Automatic Sprinkler is the heart of the Recessed Sprinkler. This sprinkler utilizes the cen- ter strut solder in compression principle of construction. The fusible alloy, captured inthecyl inder of asmall solder capsule by stainless steel ball, acts as the trigger of the sprin kler. when the fusible alloy melts, the sprin kier op er- ating parts sprinkler free from the sprinkler clearing the waterway and allowing the deflector to distribute the dis- charging water. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New Yorki 0552 t lif jj111 IL_i AM I CI4C ALI / ½" NPT Non-Adjustable Inlet 1" NPT Male-Adjustable Inlet Figure 1 Figure 2 2. Installation The Reliable Model G Recessed Sprinkler has been designed with ease of installation in mind. A choice of three inlets with up to one inch adjustment coupled with the 1/2" (13mm) escutcheon adjustment enables most system to be installed using pre-cut drop nipples. The adjustment can be accomplished after the ceiling instal- lation and while the system is pressurized thereby provid- ing sprin klerprotection before con struction is completed. The Non-Adjustable inlet version (Figure 1) Con sists of the Reliable Model G Sprinkler with an attached cup re- cessed in the ceiling. A ceiling hole of 21/2"(67mm) di am- eter is recommended. The Adjustablein letversion uses the same sprin Her as the Non-Adjustable inlet version uses the same sprinkler as the Non-Adjustable in lettype ex ceptthe 1 of additional adjustment is provided by a telescoping sprinkler inlet section that threads in or out of a stationary Coupling Re- ducer (either 1 male or 1 female) as shown in fig ures 2 or 3. The Sprin Her-Cup as sem blyco mes attached to the in- let Coupling Reducer Comes attached to the inlet Cou- pling Reducer and is retained from separation past its maximum adjustment length by a snap ring. This combi- nation is simply installed after the system drop nipple, el - bow or tee has been "roughed in" to the dimensions shown in figures 2 or 3. Wrenching means are provided by hex flats on the coupling reducer as depicted in the figures-do not wrench on any other part of the sprinkler. After the ceiling tiles have been cut and in stalled in place (a 21/4" [57mm)hole is recommended), the sprinkler can be adjusted using the RC-1 Concealed Wrench. When using the wrench in this application, however, do not over-torque beyond the adjustment stops. Figure 4 shows a ½" NPT (R½) non-adjustable inlet sprinkler, with the attached sprinkler cup combination in - serted into the special Reliable Model RC-1 Installation Wrench. This wrench must be used. The wrenching pads of the sprinkler easily slip into the rectangular cut-outsofthewrench as theoutside diameter locates the threaded cup. A ½" (13mm) drive ratchet can then be used for installation and tightening. Figure 5 shows the removal of the wrench. Care should be taken during this procedure to avoid hittingthe deflector with the wrench. The wrench should be lowered until it clears the sprinkler. The installation completed by threading the escutcheon on until it contacts the ceiling. To avoid leaving smudge marks on the ceiling, the Reli- able Model FEA Flush Sprinkle Escutcheon Wrench should be used. See Bulletin 205 Note: 1. Use hex wrench on Coupling Reducer to tighten Ad- justable Sprinkler into fittings. Do not use RC-1 Wrench tor this purpose. 2 Do not install the Model G Recessed Sprinkler in ceil - ings which have positive pressure in the space above. Maintenance The Model G Recessed Pendent Sprin Hers should be inspected quarterly and the sprinkler system maintained in ac cor dancewith N FPA 20. Do not clean sprinklers with soap and water, ammo niaor anyother clean ing fluid. Re- move any sprinkler that has been painted (other that fac - tory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of dam agedorop er ated sprin Hers. Priorto instal Ia- tion, sprinklers should be maintained in the original cartons and packaging until used to minimize the poten- tial for damage to sprinklers that would cause improper operation or non-operation. j(I.. I , I I. 1 !J 1" NPT Female-Adjustable Inlet Figure 3 Tk;I fl+ Total K" Factor Approval Sprinkler Identification Sprinkler Inlet Adjustment NominalOrifice U.S. Metric Thread Organizations Number (SIN) . Non-Adjustable ½" (13nmi) ½" (15rrrn) 5.62 81.0 ½" NPT (R½) 1 2,3,4,5, R1015 ' I Non-Adjustable ½"(larrn) 17/32"(11 mm) 4.24 61.0 ½"NFt(iR'/2) 1,3,4 R1013 Non-Adjustable ½" (larrn) %"(lon-rn) 2.82 40.6 ½" NP1 (1R1/2) 1, 3, 4 R1011 Non-Adjustable ½" (13rrrn) 17/" (arrrn) 7.66 114.7 1/2 NFl (R'/2) 1,3 R1016 Adjustable 11/2"(39rrn) ½"(lSnTn) 5.53 79.7 1"NPlMaleorFemale 1,2,3,4 R1118 Adjustable 11/2" (38M) 7/"(11mm) 4.24 61.0 1"NPlMaleorFemale 1,3,4 R1113 Adjustable 1112" (39Tn1) 11(10rrrn) 2.75 39.2 1" NFl Maleor Female 1,3, 4 R1117 Adjustable 1½"(rm) 15rrrn 53 79.7 RlMaleorFemale 5 R1118 * Sprinkler escutcheon provides ½ (13mm) of the total adjustment. Adjustable inlets, when used, provide 1 (25mm) of the total adjustment. (1) Identified by pintle extending above the deflector. Tcmncrfi ir Rifinns Maximum Ambient Sprinkler Rating Temperature °F °C °F Classification Ordinary Ordinary 135 166 57 74 100 100 38 38 Intermediate 212 100 150 66 Approval Organizations Underwriters Laboratories Inc. Factory Mutual Research Corp. Light Hazard Occupancies - No limitations Ordinary Hazard Occuncies - Groups 1 & 2, Wet Systems Only Underwriters Laboratories of Canada NYC BS & A No. 587-75-SA Loss Prevention Council XLH, OHI and OHII Occupancies Only 6. NYC MEA 258-93-E Note: Unless otherwise indicated, Ordinary hazard ap- provals are without limitations. (11mm) and (10mm) orifice sprinklers are limited to light hazard OC CU- pancies. Figure 4 Ordering Information Specify: 1. Temperature Rating 2 Nominal Orifice 3 Sprinkler Finish 4 Escutcheon Finish 5 Sprin kier Type: Either Non-Adjustable In let (Fig. 1); 1" Male Adjustable Inlet (Fig. 2); 1" Female Adjustable Inlet (Fig.3) Iinichcc (1) Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome White Painted White Painted Special Application Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Satin Satin Polyester Coated PolyesterCoated Other color Finishes avail ableupon request. Con suit I-ac torytor details. Only frame, deflector and cap are plated Only frame and deflector are painted or coated. Operating parts are chrome plated. UL Listed and MEA Approved only. Figure 5 3. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers guards Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Supertrol electrical system Sprinkler emergency cabinets Sprinkler Wrenches Sprinkler escutcheons and Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bul le fin istobein stalled in accordance with the latest per ti nentStandardsoftheNationaJFireProtecfion As sociation,FactoryMutual Research Corporation, orothersim i larorganizallonsand alsowith the provisions of governmental codes or ordinances when everapplicable. Prod uctsman u tac tured and distributed by Re liable have been protecting lifeand property for over 80 years, and are installed and serviced by the most highly quaIl fled and rep u table sprin klercorr trac torslocated throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprin klerCo., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 CorporateOffices www,reliablesprinWer.com Internet Address ®Recycled Paper Revision lines indicate updated or new data EG. Printed in U.S.A. 12100 P/N999997006