HomeMy WebLinkAbout2525 EL CAMINO REAL; ; FA050114; Permit11/21/24, 9:34AM FA050114 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA050114 2525 EL CAM INO Job Address: Status: ISSUED REAL Permit Type: FALARM Applied 12/14/2005 Parcel No: 1563020900 Approved: 12/20/2005 Lot #: 0 Reference No.: Issued: 12/20/2005 PC #: Inspector: Project Title: WEI MAN SHOES FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: SIMPLEX GRINNELL 9855 CARROLL CANYON RD SAN DIEGO CA 858-740-0100 Owner: PLAZA CAM INO REAL C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) __- 115 0 115 0 about:blank 1/1 FA050 I I+ tqcci /Fire & IS implex6rinnellf Security SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tale: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM PRODUCT SUBMITTAL PROJECT: Weiman Shoes Plaza Camino Real 2525 El Camino Real Carlsbad, CA 92008 12/8/2005 REV.#: 0 PROJECT #: 480401977-05 tqco / Fire & / SimplezGrinnell Security SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM ITEM QTY MODEL NO. DESCRIPTION C.S.F.M. NO. A 1 4005-9101 Fire Alarm Control Panel 7165-0026:212 2 2081-9272 6.2AH Battery N/A B 8 4098-9788 2 Wire Base with LED 7300-0026:222 8 4098-9601 Photoelectric Smoke Detector 7272-0026:219 C 1 4905-9938 Sync Module 7125-0026:235 D 1 4906-9130 Horn/Strobe Only Multi-Candela 7125-0026:317 12/8/2005 REV.#: 0 PROJECT #: 480401977-05 05implex UL, ULC Listed FM, CSFM, and NYC, MEAApproved* STANDARD FEATURES 80 Character, alphanumeric LCD readout with wide viewing angle Eight, Initiating Device Circuits (lDCs), Style B (Class B) Four, Notification Appliance Circuits (NACs), Style Y (Class B) Four amp power supply/battery charger Power limited design Pluggable terminal blocks Internal DACT Simplex® system accessory compatibility: - 4602 Series Remote Control Unit (RCU) and Status Command Unit (SCU), two-wire serial communications - 4601 Series Annunciators - 4003 Voice Control Panels - 4009 NAC Power Extenders SOFTWARE FEATURES Menu-driven programming On-site programmable custom labels Four operator access levels Historical event logs Circuit selectable alarm verification WALKTESTTm performance testing** Selectable active status reminder OPTIONAL FEATURES Expansion modules: - Two circuit IDC, two circuit NAC/relayt - Four circuit NAC/relayt - Four circuit IDC (low current and high current versions) - Four circuit Style D/Style Z (Class A) NAC or IDC zone conversion - Eight circuit I/O module - Remote station/city connection Additional five amp power supply * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:212 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. See page 7 for ULC designations. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. LifeAlarm® Fire Alarm Controls Fire Alarm Controls 4005 Series Fire Alarm Control Panels; Eight to Thirty-Six Zones Model 4005 Fire Alarm Control Panel INTRODUCTION For areas requiring eight to thirty-six IDC zones, Simplex 4005 series fire alarm control panels provide flexible initiating circuit monitoring, extensive programmable control capability, and LCD annunciated circuit-specific custom labels. Surface mount components, efficient microprocessor programming, and easy-to-use control panel operation combine to provide an extensive feature list in a compact, "installation friendly" package. Panel status and circuit information is efficiently indicated by an alphanumeric LCD readout featuring two lines of 40 characters each. The panel control switches are clearly marked for intuitive operation. Programming of the selectable features is performed by using the display and the panel control switches while in the programming mode. APPLICATIONS The 4005 series fire alarm control panel provides protection for a wide variety of mid-size facilities in the following fields: Educational, Health Care, Business, Storage, Hospitality, Residential, and General Assembly. Its modular design allows IDCs and NACs to be incremented in groups of two or four to satisfy circuit requirements without specifying excess capacity. If the system expands, then additional "snap-in-place" modules can be easily installed on-site. ** WALKTEST performance testing is protected under US Patent No. 4,725,818. t NACs may be individually configured for dry contact relay operation. NOTE: Contact your local Simplex product supplier for fire alarm control panels suitable for Release Control applications. S4005-0001-7 8/02 4005 STANDARD CONFIGURATION INCLUDES: 4005 Central Processing (CPU) Board: - Contains the main microprocessor and 4005 programming, evaluates the status of all I/O modules, processes the required responses, and provides a watchdog timer that resets the panel in the event of an abnormal operation - Controls the LCD readout and switches that comprise the operator interface - Controls the flash EPROM that contains the non- volatile site-specific programming information - 4-Wire Smoke Detector Power. Dedicated terminals, 5 second reset, rated 24 VDC, 500 mA, open collector type, power limited and short circuit protected - Remote Unit Serial Interface (RUI). Connections for up to 16, style 4 (class B), supervised remote annunciators model 4602-9102, Remote Control Unit (RCU), or 4602-9101, Status Command Unit (SCU). (Further described under Accessories on page 5.) Power Distribution Board: - Connections for up to 5 plug-in module cards - Auxiliary power connections. Two, 24 VDC, each rated for 2 A, power limited. Connections are isolated from NAC power. Power Supply/Battery Charger: - Switch Selectable for 120 or 240 VAC - 24 VDC Power, 4 A, regulated and power limited, is available specifically for notification appliances and auxiliary output use, via two taps of 2 A each. - InternaIt .Oi Js supplied via - Battery Charging for up to 18 Ah batte 'ithin the 4005 cabinet and up to 33 Ah thin mounted in an external battenica - FunctioiiMoIttrii .ns:iffissing, depleted, and low battery, Earth fault detection, AC power loss, AC power brownout (low input voltage), signal power overload, supply voltage monitoring, and charger failure. - Depleted Battery Trouble Indication advises when standby operation has exceeded battery capacity. Internal DACT Module: - Reports Alarm, Supervisory, Trouble, and AC Failure - Dual line operation with automatic 24 hour test and programmable power fail report delay Eight, Initiating Device Circuits (lDCs): - Two, 4 circuit IDC plug-in modules are standard, providing 8, Style B (Class B) lDCs - Standard lDCs are low current, support up to 20 Simplex detectors per IDC, 2 mA maximum (for detectors with relay bases, use high current expansion modules, see chart on page 7). tDCs (Continued): - lDC operation is individually programmable with the following operating mode choices (an abbreviated mode description is part of the IDC display information): Combination Fire/Emergency Combination Smoke/Fire Zone Combination Smoke/Manual Station Current Limit=Fire Alarm, Short/Open=Trouble Duct Detector Fire Alarm Generic Fire Pump Monitor Flame Detector Generator Monitor Heat Detector Latching Supervisory Manual Station Non-Alarm Utility Smoke Detector Sprinkler Supervision, Normally Open Sprinkler Supervision, Normally Closed Supervisory Fire Pump Monitor Supervisory Generator Monitor Supervisory, Generic Trouble Monitor Verified Generic Verified Smoke Zone Verified Combination Smoke/Fire Zone Verified Combination Smoke/Manual Station Waterflow Switch Waterflow/Sprinkler Supv., Normally Open (WSO) Waterflow/Sprinkler Supv., Normally Closed (WSC) Four, Notification Appliance Circuits (NACs): - One, 4 circuit NAC/Relay plug-in module is standard, providing 4, Style Y (Class B) NACs that can be individually reconfigured for dry contact relay operation. - NAC operation is individually programmable as Steady Signaling, Temporal Coded, March Time @ 20 BPM, or March Time @ 120 BPM, and with the following operating modes (an abbreviated mode description is part of the NAC display information): AHU On/Off Relay, Single Relay Control AHU On Relay, Dual Relay Control AHU Off Relay, Dual Relay Control Audible Signal, On-Until-Silenced Audible Signal, On-Until-Reset Doorholder Control Elevator Capture, Primary Elevator Capture, Alternate Generic Signal Sprinkler Supervisory Signal, On-Until-ACK Trouble/Supervisory Signal, On-Until-ACK Trouble/Supervisory Signal, On-Until-Clear Visible Signal, On-Until-Silenced Visible Signal, On-Until-Reset Waterflow Signal, On-Until-Silenced Waterflow Signal, On-Until-Reset S4005-0001-7 8/02 page 2 Notification Appliance Circuit (NAC) Relay Mode Operation: - NAC/Relay Selection. Each NAC can be on-site selected for NAG operation or for unsupervised, dry contact, auxiliary relay operation. When operating in the relay mode, either the normally open or the normally closed contact can be connected to the output terminal block. Contacts are rated at 2 A, 32 VDC, for transient suppressed loads - Relay Operation is individually programmable with the following operating mode choices (an abbreviated mode description is part of the relay display information). 4005 BASIC OPERATOR FUNCTIONS Display Indications Upon receiving an abnormal condition of alarm, supervisory, or trouble, the 80 character backlit LCD will identify the quantity and type of abnormal indications. With the locked door closed, the display, status LEDs and primary operator switches are visible through the transparent door viewing panel as shown in FIGURE 1. This figure represents the LCD during normal conditions showing normal status, time, and date. FIGURE 2 represents typical fire alarm display screens. SYSTEM IS NORMAL 12:02:15pm Fri 22-Feb-02 FIRE SYSTEM SYSTEM ALARM'AC ALARM ST ISORY TROUBLE SILENCED POWER SYSTEM AK K ACK SILENCE RBSEJ FIGURE 1. Basic Operator Function Keys with Normal Display of Status, Time, and Date For this example, the presence of three fire alarm conditions is shown in the top screen - fire zones 2, 7, and 6, displayed in chronological order of occurrence (up to 10 zones may be shown). The display will alternate with the one shown below it as the operator is prompted to assist with the next required action. FIRE =3 SUPERVISORY =0 TROUBLE =0 FIRE ZONES 02 07 06 FIRE =3 SUPERVISOR-Y=O TROUBLE =0 " FIRE ** Press ACK to Review FIGURE 2. Typical 4005 Displays with Alarm Activity RELAY MODES: AHU On/Off Relay, Single Relay Control AHU On Relay, Dual Relay Control AHU Off Relay, Dual Relay Control Alarm Relay, On-Until-Silenced Alarm Relay, On-Until-Reset Doorholder Control Elevator Capture, Primary Elevator Capture, Alternate Generic Relay Sprinkler Supervisory Signal, On-Until-Acknowledged Trouble/Supervisory Signal, On-Until-Acknowledged Trouble/Supervisory Signal, On-Until-Clear Visible Signal, On-Until-Silenced Visible Signal, On-Until-Reset Waterfiow Signal, On-Until-Silenced Waterfiow Signal, On-Until-Reset Alarm ACK, Supervisory ACK, Trouble ACK The ALARM ACK, SUPV ACK, or TROUBLE ACK key will silence the local tone-alert, corresponding to the type of abnormal condition. Subsequent entry of the appropriate ACK key will chronologically scroll through the specifics for each abnormal condition. Screen information includes custom labels for each zone that provides a detailed report of the location, device type description, device condition, and list count for the first point in the Alarm, Supervisory, or Trouble list. FIGURE 3 represents a typical screen that would appear after using the ALARM ACK key to scroll to the first fire condition. It displays the zone location as "First Floor East Wing Room 12", the device type as 'Smoke Detector" and the device condition of 'Alarm". The 1/3 indicates that the displayed alarm is the first of three alarms present in the panel at this time. Site-specific labels can be upper or lower case and can provide a discrete annunciation that can assist fire response with clearly defined zone locations and device types. First Floor East Wing Room 12 Smoke Detector ALARM 1/3 FIGURE 3. Typical 4005 Fire Alarm Information Custom Label Display Alarm Silence The ALARM SILENCE key will silence the notification appliances programmed for on-until-silence (typically audible notification appliances) and the ALARM SILENCED LED will remain illuminated until the panel is reset. System Reset When the source of the abnormal condition is corrected, the SYSTEM RESET key will reset the panel and return the status to normal. S4005-0001-7 8/02 page 3 4005 EXPANDED OPERATOR FUNCTIONS AND PROGRAMMING INFORMATION SYSTEM IS NORMAL** 12:02:15pm Fri 22-Feb-02 FIRE SYSTEM SYSTEM ALARM AC ALARM SUPERVISORY TROUBLE SILENCED POWER CS ACK ACK ACK SILENCE RESET) W WDbIeW W W WW W Menu AdlmIi e I A Enter A IPreviousi A FIGURE 4. The Complete 4005 Operator Interface Includes Nine Expanded Operation/Programming Keys Passcode Access The 4005 has four levels of passcode access: Level I is basic access and is available by unlocking the door. Access includes the standard operator functions and historical log information. Levels 2 and 3 are on-site programmable to control functions required by local needs such as clock set, enable/disable, Walk Test, and custom label changes. Level 4 access provides passcode programming of critical life safety functions, access level programming, and service level diagnostics and programming. Expanded Operator Functions Unlocking the door provides access to the operator control panel and reveals nine additional keys used for expanded operator functions and for circuit type and programming selections (refer to FIGURE 4). The following expanded operator functions are available: - Circuit Disable/Enable, available for each individual IDC, NAC, or relay circuit. - WALKTEST Performance Testing allows a single fire alarm system tester to manually initiate remote alarms and troubles and obtain a verification output from the NACs with an automatic Reset. Alarms are initiated to produce a pulse count that identifies the zone. With the zone number confirmed, troubles can be then initiated with a common pulse output for a complete functional test of each zone. - Indicator Test confirms that all panel LED and LCD indicators are properly functioning. - History Logs provide up to 50 fire alarm logs and up to 100 trouble logs. They are available for chronological review as fire, trouble, or fire and trouble combined. Programming NOTE: During programming, monitoring remains active and the 4005 will perform enabled responses. Programming Operations Include: - Abort Enable, 30 second delay allows zone status confirmation before enabling. - Alarm Cutout time delay. - Active Status Reminder (Alarm/Supervisory/Trouble Resound every 8 hours). - Alarm Silence Inhibit Timer. - Assignment and selection of passcodes and access levels. - Custom control equations. - Custom label generation and revision. - Doorholder time delay (drop upon Alarm, drop upon AC power loss). - IDC circuit type (reference list on page 2). - Module allocation and identification. - NAC or Relay circuit type (reference lists on pages 2 and 3). - NAC/Relay output coding of: Steady Signaling, Temporal Coded, March Time @ 20 BPM, or March Time @ 120 BPM. - Selling of time and date, and selection of 12 or 24 hour format. Menu Selection and Response Keys: The 4005 LCD provides menu driven prompts for performing functions. Navigating through the menu is easily performed by using the operator keys at the bottom of the interface panel (see FIGURE 4). - Menu always produces the main menu. - Function provides a list of the available actions that can be performed depending on which programming or functional area is being displayed. (continued next page) S4005-0001-7 8/02 page 4 Menu Selection and Response Keys (Continued): - Disable/Enable toggles status of the displayed circuit. - Exit/Clear provides a path out of the chosen menu and allows manual entries to be cleared. 4005 SYSTEM OPTIONAL MODULES Class A (Style D/Style Z), 4 Circuit Adaptor Module for either IDCs or NACs (4005-9806): - Individually isolated circuit design adapts either IDCs or NACs for Class A operation allowing a combination of circuit types - Mounts on top of the module, maintaining full module capacity Power Distribution Module (4005-9807): - Extends 4005 capacity to ten plug-in modules - Mounts on left side of 4005 chassis - Required when plug-in module requirements extend beyond five and/or for connection of expansion power supply 4005-9813 City Circuit Module (4005-9809): - Single circuit, selectable as local energy, reverse polarity, or form 'C' contact 4005 SYSTEM CAPACITY EXPANSION MODULES Optional and expansion modules can be easily installed and programmed on-site. Their "snap-in-place" design installs without tools or hardware, allowing configuration for the initial system capacity or for later system expansion. 2 Circuit IDC with 2 Circuit NAC/Relay (4005-9803): - Two, standard low current IDCs, for up to 20 detectors per IDC, 2 mA maximum - Two circuits, individually on-site selectable as either Style B (Class B) NAC, or N.O. or N.C. relay circuits - Combined on one plug-in module - Operation and programming is the same as the standard control panel IDCs and NAC/Relay circuits 4 Circuit IDC Module (4005-9804): - Four, standard low current IDCs on one plug-in module, for up to 20 detectors per IDC, 2 mA maximum - Operation and programming is the same as the standard control panel IDCs 4 Circuit NAC/Relay Module (4005-9805): - Four, NAC/Relay Circuits on one plug-in module ACCESSORIES 4602 Series Annunciators: - Supervised Serial communications with twisted, shielded pair - SCU has 16 LED zone status indicators - RCU has 8 LED zone status indicators, Power-On LED and Trouble LED, Local tone-alert, and - Enter confirms the selection made and enters program changes into memory. - Left, Previous, Next, and Right arrow keys move the display cursor or select screens or specific choices, depending on the displayed functional area. City Circuit Module (Continued): - Reverse polarity is selectable for Alarm/Trouble, Alarm, Supervisory, or Trouble only reporting - Up to two modules mount directly to 4005 chassis below the CPU assembly Expansion Power Supply (4005-9813)- - Regulated 24 VDC, rated at 5 A - Power Limited Design - Installs on the left side of the 4005 chassis and fits behind expansion modules, allowing full module capacity - Switch selectable for 120 VAC or 240 VAC Provides additional power for notification appliances, 4-wire detectors, annunciator power, or other fire alarm auxiliary functions 4 Circuit NAC/Relay Module (Continued): - Operation and programming is the same as the standard control panel NAC/Relay circuits 8 Circuit I/O Module (4005-9808): - Select each circuit as either an input or output - Input mode supervises hard wired connections to 4601 Series annunciator switches or utility switch inputs - Output mode is rated 24 VDC, 150 mA open collector driver, short circuit protected, UL listed for pilot duty - Output mode provides supervised auxiliary control of a compatible annunciator or remote relay for emergency control in accordance with NFPA 72 and NFPA 101 4 Circuit IDC, High Current, Required for Detectors with Relay Bases (4005-9824): - Four, high current IDCs on one plug-in module - High current operation for up to 30 detectors per IDC, 3 mA maximum detector power (required for detectors with relay bases) - Operation and programming is the same as the standard control panel IDCs keyswitch enabling of Trouble and Alarm Silence, System Reset, and Manual Evacuation 4601 Series Annunciators: - Provides LED status indications and switches for acknowledge, silence, and reset - Modular design allows sizing as needed S4005-0001-7 8/02 page 5 ACCESSORIES (Continued) 4001-9810 Fire Alarm System Control Relays - Four Alarm Relays mounted on a 6 gang plate, coils rated 20 mA each at 24 VDC - Contacts rated 1/2 A at 120 VAC, 2 A at 30 VDC, for transient suppressed loads 4005-9150 and 4002 Adapter Kits for Retrofit: - Replace existing 4002 Fire Alarm Control Panels with the 4005 panel features, supplied with high current IDC modules for convenient retrofit - Cabinet, door, and electronics may be ordered separately to satisfy early cabinet (backbox) installation requirements Specifications [Electrical Standard Panel Input (Switch Selectable) 102-132 VAC, 60 Hz; 2 A maximum 204-264 VAC, 50/60 Hz; 1 A maximum Main Power Supply Output* 4 A @ 24 VDC (Regulated) Expansion Power Supply Input (Switch Selectable) 102-132 VAC, 60 Hz; 3 A maximum 204-264 VAC, 50/60 Hz; 1.5 A maximum Expansion Power Supply Output* 5 A @ 24 VDC (Regulated) 8 Circuit I/O Module Input Mode Output Mode Dry Contact, supervised with 2.2 kc end-of-line resistor 24 VDC, 150 mA, open collector NAC Operation, Per Circuit 24 VDC nominal, 2A maximum Relay Operation, N.O./N.C. 2 A @ 32 VDC Resettable 4-Wire Smoke Detector Power 24 VDC, 500 mA, open collector Auxiliary Power Connections (two taps) 2A@24 VDC maximum each tap, power limited General On-Site Wiring Terminal Blocks Pluggable type, wire size is 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Operating Temperature 32° F to 120° F (0° C to 49° C) Operating Humidity Range I up to 93% RH, non-condensing @ 90°F (32° C) *NOTE: Power supply output currents listed are entirely available for NAC appliances and auxiliary equipment. 4005 modules are powered from separate circuits. Battery Requirements (refer to document 900-012 for battery selection) Module Quantity J rm Quantity Standard PanelT I Includes 2,4005-9804 & 1,4005-9805 111 135 61 Select Includes 2,4005-9824 & 1, 4005-9805 one 4005-9150, Electronics OnIy Seoarate Modules: Standard. ODtional. and Exnansion: see NOTES ( below 4005-9806, Class A Adapter 1 x = 33 x = 4005-9807, Expansion Power Distribution Module 1 x = 1 x = 4005-9809, 1 Circuit Remote Station/City Connect 10 x = 10 x = 4005-9813, Expansion Power Supply 12 x = 12 x = 4005-9803, 2 lOG, Low Current, and 2 NAC/Relay (1, 2, 3, 4, 5) 14 x = 34 x = 4005-9804,4 IDC, Low Current (1,2,3) 23 x = 57 x = 4005-9805, 4 NAC/Relay (5) 3 x = 34 x = 4005-9808, 8 Circuit I/O Module 1 x = 1 x = 4005-9824,4 IDC, High Current (1,2,4) 40 x = 94 x = Internal DACT (aftermarket PID 4005-9810) (6) 30 x = 30 x = t Standard panels and 4005-9150 include IDC loop currents for both supervisory and alarm. Total, 4005 Modules Total, 4-Wire Detector Power + + Total, Other Auxiliary Power + + Total, Notification Appliance Power + + Total Supervisory Current Total Alarm Current NOTES: IDC supervisory currents include loop currents of 2 mA/circuit for "low" current lOCs and 3 mA/circuit for "high" current lDCs. IDC Alarm currents, add as required. Low current lDCs = 30 mA/circuit; High current lOGs = 65 mA/circuit. Add 8 mA supervisory current per SC, WSC point used. Add 10 mA supervisory current per SC point used. Add 8 mA supervisory current per circuit if used as auxiliary relay and programmed for normally on. DACT Current is 45 mA when reporting. S4005-0001-7 8/02 page 6 293 one 4005 Product Selection Chart Category Model Description Standard 40059101* Beige 4005 Fire Alarm Control Panel; includes: 8 standard lDCs, 4 NAC/Relay Control Panels cabinet I circuits, 4 A power supply, internal Dual Line DACT, cabinet and door 40059102* Red cabinet (DACT requires one cable per line, see Accessories on page 8) Electronics 4005-9150 4005 Fire Alarm Control Panel, 8 high current lDCs, 4 NAC/Relay Circuits, 4 A power Only supply, requires 4002 Adapter Kit or separately ordered cabinet and door Four Circuit Class A (Style Z/Style D) Adapter Module for use with IDC and/or MAC 4005-9806 modules, standard or expansion; mounts on top of plug-in IDCINAC module; circuits convert either NAC or IDC, or combination, compatible with module being adapted Additional Five Slot Power Distribution Module, required 4005-9807 when plug-in module count exceeds five, or for connection of Qty, 1 Max. ____________ Expansion Power Supply Optional Modules 40059809** Single (1) Circuit City Module , chassis mounted, below CPU _______________________________ Qty, 2 Max.** __________ Internal Dual Line DACT; aftermarket add-on; for connecting to 40059810** RJ31X Telco jacks, requires one DACT cable per line (see 4005 Qty, 1 Max.** Accessories on page 8) Expansion Power Supply, 24 VDC, 5 A, regulated; chassis mounted 4005-9813 beneath left side modules; requires 4005-9807 Power Distribution Qty, 1 Max. Module. Expansion 4005-9803 Standard Operation, 2 Circuit IDC with 2 NAC/Relay circuits Modules 4005-9804 Standard Operation, 4 Circuit IDC Module (system capacity is 10 expansion slots, 4005-9805 4 Circuit NAC/Relay Module 3 expansion slots 4005-9808 are used in base 8 Circuit Programmable I/O Module panel) 4005-9824 4 Circuit IDC Module, high current operation, Class B, for detectors with relay bases Cabinets 2975-9209 Beige 4005 Cabinet 2975-9210 Red 4005 Cabinet Order cabinets if required for pre-installation. 4005-9150 Electronics only model requires a Doors 4005-9857 Beige Door cabinet and door or a 4002 Adapter Kit. 4005-9858 Red Door 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC 2081-9288 2081-9288 12.7 Ah Battery, 12 VDC required Batteries (select one set, 2081-9275 18 Ah Battery, 12 VDC refer to chart on page 6) 2081-9271 33 Ah Battery, 12 VDC I F Requires External Battery Cabinet 4009-9802 External Battery Cabinet, beige with solid door; includes battery harness; for mounting 4009-9802 close-nippled to 4005 cabinet. Cabinet size: 25-3/4" W x 20-3/4" H x 4-1/8" D (654 mm x 527 mm x 105 mm) 4005-9850 Two Unit, 4002 Adapter 4002 Cabinet size Includes 4005 chassis adapter plate with beige 4005-9851 Four Unit Kits retainer panel 4005-9852 Six Unit (for mounting 4005-9150 electronics into a 4005-9853 Two Unit Simplex Model 4002 Cabinet size Includes 4005 chassis adapter plate with red 4005-9854 Four Unit 4002 cabinet) retainer panel 4005-9855 Six Unit * ULC listed models are designated with a suffix of "C" for English and "CF' for French (example: 4005-9I0ICF). ** DACT module is standard equipment on 4005-9101 and 4005-9102. Operation allows for either a DACT module or one or two City Connection modules. The DACT is programmed using a terminal or a laptop computer in terminal emulation mode. Connection and programming details are provided with the Installation Instructions (publication 574-049). For further 4005 information, refer to Field Wiring Diagram 841-990 and Installation Instructions 574-068 S4005-0001-7 8/02 page 7 4005 Accessories Selection Chart [_Model Description 4602-9101 Status Command Unit (SCU), 16 LED serial connection annunciator Remote Command Unit (RCU), 8 LED serial connection annunciator with remote tone-alert and control 4602-9102 panel status LEDs, and switch control for Trouble and Alarm Silence, System Reset, and Manual Evacuation (4602 Series Annunciators are available for multiple packaging applications, for further information, refer to data sheets S4602-0001, S4602-0004, and S4602-0005) 4601 Series e LED/Switch Annunciators, modular design allows selection of required LEDs and control switches (refer to data sheet S4601-0002) 4001-9810 Four Alarm Relays mounted on a 6 gang plate, Coils: 20 mA each at 24 VDC, Contacts: 1/2 A at 120 VAC, 2 A at 30 VDC, for transient suppressed loads 2080-9047 DACT Cable with RJ45 Plug, 14 ft long (4.3 m); required for DACT use MOUNTING DIMENSIONS Conduit knockouts are provided on top and bottom Reference, 24' stud centers Knockouts are provided for nailing. Two on each sjde and width = 22-1/2" (572 one each on top and bottom. I • •• • amU U U-UU •• • •.• •.•U'•U MEN ass S ON 010 am: U 0 •• Uan 8 U N'S •U U'• arm• •U •UUU UU a US an UU Drywall markers indicate 1/2' (13 mm) depth, two on each side 24" (610 mm) .. UU UUU UU-•U •U U• •• •• •• .. US UU UU•U-UU S• .. .. U.. es eu •• UU U• •U •• •••U •UUU UU CU .. U. UUU •• •• •U •U s•U •U'UU UU ••••U••• CU U. US UUU •U •• •• •U U• sUU U. UU U• U••C•• S• (594 NBox includes an 0.048' (1.2 mm) thick trim for semi- flush mounting. Height and width are same as door. I 23' I (584 mm) 1/2" L 3-7/8" (13 mm) (98 mm) NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, article 250, and NFPA 780. Tyco, Simplex, the Simplex logo, Life Alarm, and WALKTEST are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 70, NFPA 72, and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). O Sirtiplex TEPG-US • 91 Technology Drive • Westminster, Massachusetts• 01441-0001 • USA S4005-0001-7 8/02 © 2002 TEPG-US (a Tyco company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:212 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Model 4005-9101 and 4005-9102 fire alarm control units. Coded, non-coded, local, local, auxiliary, remote station, proprietary and central station fire alarm service; automatic, manual and waterfiow alarm and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 565-469 CPU Board 565-479 Power Supply Board 565-471 Power Distribution Board 565-473, -610 Four Point IDC Board 565-477 Four Point NAV/Relay Board 565-522 IDC/NAC Relay Board 565-536 Class A Adapter Board 565-554 Eight Point I/O Board 565-481 Expansion Power Supply 565-550 City Circuit Board 2080-9044 DACT 4005-9810 DACT 2088-9007 Shunt Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire control units for use with separately listed compatible initiating and indicating devices. The control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to listee's Installation Instructions Manual for details. NOTE: For Fire Alarm Verification Feature, the maximum Retard/Reset/Restart must be adjusted to 30 sec. or less. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 5$implex Fire Alarm Control Panel Accessories Cabinet Mounted System Batteries; 2081 Series, Sealed Lead-Acid; 6.2 Ah to 50 Ah Rechargeable, sealed lead-acid design: Lead-calcium grid structure Immobilized electrolyte in absorbent separator High reliability dual seal construction Low maintenance, no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size For applications requiring 110 Ah batteries: Refer to data sheet S4081-0002 for 4100U systems Refer to data sheet S2081-0012 for 4100/4120 series system JU Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. I:fl'I Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery* capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets I Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. [Specification Summary Nominal Voltage Rating 12 V/battery Discharge Rating 20 Hour Rate Typical Chart/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. S2081-0006-16 9/2004 Inner cover Absorbent sei used to imrr e1e Lead-calciur C Typical Construction Details Actual appearance will vary with battery size. QnInr1 ni ifar -- Cell case (high impact polystyrene) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator S2081-0006-16 9/2004 Battery Specifications [Battery Model ____ - Width* Depth* Height with Terminals Approximate 2081-9272 6.2 Ah 6-1/8" (156 mm) 2-5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081.9274 ______ 6"(153 mm) 4-1/16" (103 mm) 4"(102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah (153 mm) (102 mm) 4(102mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) (127 mm) (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 (square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9-1/2" (241 mm) 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Simplex Control Panel Model Series (see legend and notes below) Capacity Model 4003 4004 4 004R 4005 4006 & 4009 4010 4100U 4100 &4120 4020 4008 (all models) (2 or 3 bay) (2, 4 or 6-Unit) (2, 4 or 6-Unit) 2081-9272 6.2 Ah / / / / / / / / / / 2081-9274 10 Ah 1 / / / / / / / / / 2081-9288 12.7 Ah 2081-9275 18 Ah / Note 3 / Ext Ext Note 2 2081-9287 25 Ah F Note 3 Ext / / / Ext 2081-9271 (rectangular) 33 Ah Note 3 Ext Note 3 / Ext Note 4 2081-9276 33 Ah Note 3 Ext Note 3 / / Ext square 2081-9296 50 Ah Note 3 Note 3 / Ext Ext / = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 Shaded areas = Not applicable NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. S2081-0006-16 9/2004 External Battery Cabinet Compatibility Reference Externally Mounted Battery Battery Cabinets without Chargers Battery Capacity Cabinets *j fl Chargers ___________ (connects to charger in panel) _________ __________ ''Model - 4081 _________ _________ __________ 2081-9301— 20819303es Seriest 2081-W70- 2081-9281 20814282.. 4009-9801 4009-9802 2081-9275 18 Ah 2081-9287 25 Ah 2081-9271 I I I I I I I (rectangular) 33 Ah 2081-9276 I I I I 1 1 ("square) 2081-9296 50 Ah * Batteries smaller than those listed are normally mounted in the product cabinet. - ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. 1= Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specification Reference Model Description . -. Color Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 2081-9270* External battery cabinet without charger Red 26-1/2" W x 12" H x 12" D 2081-9301 External battery cabinet with charger. 2081 9302* External battery cabinet without charger and with meters for voltage and current (673 mm x 305 mm x 305 mm) 2081-9303 External battery cabinet with charger and with meters for voltage and current 4009-9801 For up to 18 Ah External battery cabinet without charger, 16-1/4" W x 13-1/2" H x 4-1/8" 0 batteries with solid door and battery harness, for close-nippled mounting to fire alarm control panel cabinet Beige (413 mm x 343 mm x 105 mm) 4009-9802 For up to 33 Ah 25-3/4" W x 20-3/4" H x 4-1/8" D batteries . (654 mm x 527 mm x 105 mm) 4081 For up to 50 Ah Companion cabinet with charger for the Beige or 22-1/2" W x16-3/4" H x 8-3/8" D Series** batteries 4010 and 4004R fire alarm control panel Red (572 mm x 425 mm x 213 mm) * Refer to Simplex data sheet S2081-0002 for additional information. ** Refer to Simplex data sheet S4081-0001 for additional information. Tyco, Simplex, and the Simplex logo are trademarks of Tyco international Services AG or its affiliates in the U.S. and/or other countries. SirripIex Tyco Safety Products Westminster- Westminster, MA. 01441-0001 USA S20981-0006-16 9/2004 www.tycosafetyproducts-usa-wm.com 02004 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. 5$implex TrueAlarm® Smoke Detectors UL, ULC Listed; FM, CSFM, TrueAlarm Photoelectric Smoke Detectors and MEA (NYC) Approved* for Two-Wire and Four-Wire Bases Photoelectric smoke detector with on-board TrueAlarm sensitivity drift compensationt UL listed to Standard 268 Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: 4098-9601, Standard Sensitivity, nominal 2.8%/ft obscuration 4098-9605, Special Application Sensitivity, nominal 3.5%/ft obscuration Available base options: Bases for 2-wire or 4-wire operation Auxiliary alarm relay output Optional remote alarm indicating LED Simplex® TrueAlarm photoelectric detectors provide many of the proven TrueAlarm analog sensing features for applications where detectors are connected to conventional 2-wire or 4-wire initiating device circuits (IDCs). Each TrueAlarm detector has an on-board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. TrueAlarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high performance smoke capture abilityt. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. 4098-9601 TrueAlarm Photoelectric Detector Mounted in Base Specifications Voltage 15 to 32 Vflfl from Fire Alarm Control Standby Current 100 1.sA @ 24 VDC k Alarm Current, 2-Wire Up to 86 mA maximurixact current is Operation 07 eerniined bylairrent limiting of Alarm Current, 4-Wire Operation 24 mA typical @ 24 VDC Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/mm (0-610 m/min) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 15° to 122° F (-9° to + 50° C) Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non-condensing Color Frost White 4-7/8" Dia. x 1-7/8" H, mounted in base Dimensions (124 mm x 48 mm); refer to page 3 for detail ° ULc listed models are designated with a C suffix such as 4098-9601G. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety code. See CSFM Listing 7272-0026:219 for allowable values and/or conditions concerning material presented in this document. It is subject to re- examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. t TrueAlarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573. 0 S4098-0015-5 10/02 111117 "M —11 hii* Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accumulation of dust and dirt. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. (See page 3.) ri1'1iiurii Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke detector spacing of 30 ft (9.1 m) may be used as a guide. For detailed installation information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). Sensitivity Selection. The 4098-9601 standard sensitivity detector is recommended for most applications. When a special application for a reduced sensitivity detector is required, the 4098-9605 should be considered. Consult your local Simplex product supplier for assistance in determining the proper selection. dirnt SIctir Smoke Detectors ______ Description 1111inalSenSitiYitY_mpatibility 4098-9601 ________ . rueAlarm Photoelectric Detector 2.8%/ft (standard) Compatible with bases: 4098-9788, 4098-9682, and 3.5%/ft 4 - 4098-9683 Compatible Bases Option Qetails* 0989788 Wire Base with connections for IDC and LED connections are screw terminals for in/out wiring, mote Alarm LED Indicator 18 to 14 AWG 4-Wire Base with Auxiliary Alarm Relay Ratings, Single Form "C", For Suppressed Loads: Relay Contacts and connections for Power limited, 3 A @28 VDC; Non-power limited, 3 A @ 120 VAC 4098-9682 Remote LED Alarm Indicator Wiring Connections (In/Out where required): NOTE: Requires external 24 VDC for operation Relay contacts and IDC wiring, color coded 18 AWG leads; LED wiring, screw terminals for 18 to 14 AWG 2-Wire Base with Auxiliary Alarm Relay Ratings, Dual Form "C", For Suppressed Loads: Relay & connections for Remote LED Power limited, 1 A @ 28 VDC; Non-power limited, 1/2 A @ 120 VAC Indicator Wiring Connections (In/Out where required): 4098-9683 NOTE: Must be connected as the only device on the IDC to ensure relay Relay contacts and IDC (-), color coded 18 AWG leads; operation. IDC (+) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories Model - l 'Description Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes 4098-9832 Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098-9788, -9682, & -9683 4098-9830 Remote LED Indicator Mounted on single gang stainless steel plate 2098-9739 Encapsulated Dimensions: 2-1/2" x 1-1/2" x 1" I Required for 4-wire circuits using 24 VDC End-of-Line Relay (64 mm x 38 mm x 25.4 mm) I 4098-9682 base, one per circuit; select mounting type as required; wiring is Mounted on single gang 2098-9735 Plate Mounted stainless steel plate color coded 18 AWG wire leads * Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm2; 14 AWG = 2.08 mm2 S4098-0015-5 10/02 Detector Status LED Indications Status LED Indication Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * [ LED Indication Followed By .Status'--_____ - Action LED turns ON Alarm is initiated Normal, sensitivity is within None compensation range LED pulses quickly, More sensitive, out of normal 6 times in 3 seconds, then turns ON Alarm is initiated compensation range Cleaning or other service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range Does not initiate Alarm Detector is malfunctioning Service is required then turns ON * Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual 574-709 for further test and maintenance information. Dimensions and Reference Information 1/4" (6.4 mm) L11 6-3/8" (162 mm) 4098-9832 Adapter Plate I." 4-7/8" (124 mm) Base height / 1-7/8" 11/16" 1 (48 mm) (17 mm) I lIlT 1 1 h I Ill I - (with clear lens) 4098-9601 & -9605 Dimensions Mounted on Base ALARM 0 4098-9830 Remote LED Indicator (not to scale) 3 S4098-0015-5 10/02 Mounting Information - (Electrical boxes are supplied by others.) Electrical Box Requirements: Without iQj (base 4098-9788): 4" octagonal or 4" square, 1-1/2" deep Single gang, 2 deep With relay (bases 4098-9682 and 4098-9683): 4" octagonal, 1-1/2' deep, with 1-1/2" extension ring 4" square, 1-1/2" deep, with 1-1/2" extension ring Surface mount reference 4(102mm' square box 4" (102 mm) --------- octagonal box 1-1/2" (38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4" (6.4 mm) maximum recess 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and to 4" square flush mount boxes 4098-9682 and 4098-9683 include a relay module that mounts in base electrical box Smoke Detector Bases 4098-9788, 9682, & -9683 4098-9601, -9605 Smoke Detector Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). O Sirnplex TEPG-US• 91 Technology Drive• Westminster, Massachusetts• 01441-0001 • USA S4098-0015-5 10/02 02002 TEPG-US (a Tyco company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:222 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Models 4098-9682, 4098-9683, 4098-9788 and 4098-9684 detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. *Rev. 05-13-2003 ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation V criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:219 Page 1 of I CATEGORY: Photoelectric Smoke Detectors LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 0 1441 -0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Model 4098-9601, -9601TSP, -9602, -96021SP, -9605, -9605TSP; *GSA40989601 *..9602 and *..9605 photoelectric type smoke detectors. Models 4098-9602, -96021SP; and *GSA4098..9602 employs an integral 1350F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector and not intended for use in lieu of required heat detectors. Refer to.listees data sheet for additional detailed system description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with listee's listed Models 4098-9682, - 9683 or -9788 detector bases *(CSFM Listing No. 7300-0026:222) and separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager B®Simplex TrueAlert® Notification Appliances UL, ULC Listed; FM, CSFM, SmartSyncTM Control Module and and MEA (NYC) Approved* Strobe Synchronization Modules Convert conventional Notification Appliance Circuits (NACs) into SmartSync circuits or synchronized strobe circuits: SmartSync Control Modules combine separate horn and strobe NAC inputs into a 2-wire control that can silence horns while maintaining synchronized strobe operation** Synchronized Flash Modules provide a 2-wire synchronized strobe output that also operates compatible 24 VDC conventional reverse polarity notification appliances* * SmartSync Control Module (SCM) provides two-wire control to separately activate horns and strobes: Operation allows "on-until-silenced" and "on-until-reset" on the same two-wire pair while maintaining supervision continuity SmartSync horns sound as Temporal or March Time pattern, or continuous, controlled separately from strobes on the same circuit Strobes on the same circuit operate at a synchronized 1 Hz flash rate Output is either Class B or Class A Conventional strobe synchronization models: Encapsulated package with color coded wire leads provides 1 Hz strobe synchronization and maintains supervision continuity Conventional horns and other DC appliances operate on the same 2-wire circuit Models are available with Class B or Class A output Small size allows convenient mounting UL listed to Standard 1971 * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:198 and 7125-0026:235 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex® product supplier for the latest status. Lislings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. B L19 NIB BIB BIydIBI'Bd I .LflO I tii I 3NIS Ititioti I NAC C A NAC IINBOINI OUT OUT IN I * . + + 2 3 4 5 4905-9938 SmartSync Control Module (SCM), Shown Approximately 1/2 Size 4905-9922, Class A Synchronized Flash Module, Shown Approximately 1/2 Size Ti F-Twel Model 4905-9938 SCM (SmartSync Control Module) converts two conventional NAC inputs into a SmartSync two-wire NAC output. One NAC can be programmed to operate as "on-until-silenced" and would be designated as the horn control (non-coded, on continuously during alarm). A second NAC would be programmed to provide "on-until-reset" operation and would be for the visible appliance (strobe) control (also non-coded, on continuously during alarm). Power is supplied by the strobe control NAC. Selectable Horn output and Synchronized Strobes. In addition to operating the strobe and the horn independently, the SCM can be switch selected to operate the horns as temporal coded, march time coded (60 beats/minute), or on continuously. Strobes are activated with 1 Hz synchronized flashes. S4905-0003-2 9/2004 Multi-Sync Mode. Up to eight SCMs can be interconnected to synchronize system notification. Interconnected SCMs are supervised for proper circuit connection. The horn input NAC powers the Multi-Sync function. Isolated NAC Inputs. Both NAC inputs are isolated from each other and can be supplied from different control panels. Class B (Style Y) and Class A (Style Z) output operation are both supported. Earth fault detection is provided by the strobe control NAC during supervision mode. irr.mr Model 4905-9914 and 4905-9922 add the required control to activate Simplex synchronized strobes for NACs that do not provide that control. Conventional horns or other compatible 24 VDC notification appliances on the same circuit ignore strobe synchronization and operate when the NAC is in alarm. For additional information refer to Installation Instructions 579-232. For additional information refer to Installation Instructions 574-7 19. Product Selection Model Description Package Details 4905-9938 - SmartSync Control Module, Class A Dimensions: 4" x 4-1/8" x 1-1/4" D (102 mm x 105 mm x 32 mm); 10r Class B output mounts in 4" (102 mm) square box 4905-9914 Class B Synchronized Flash Module Dimensions: 1-3/8" x 2-7/16" x 13/16" D (35 mm x 62 mm x 20 mm); epoxy encapsulated with 8" (203 mm) in/out 18 AWG (0.82 mm2) wire 4905-9922 Class A Synchronized Flash Module leads; rated for 2 A NAC; requires 5 mA for power [Specifications General Specifications Temperature Range 1 32* to 122° F (0° to 50° C) Humidity Range 110% to 93%, non-condensing at 100° F (38° C) 4905-9938 SmartSync NAC Modules (for use with SmartSync compatible appliances) Input Voltage Range 16 VDC to 33 VDC; with a maximum ripple of 2 V peak-to-peak Output Ratings / 2 A maximum; can be wired as Class A or Class B Up to 35 ma S ap liances with strobes Up 40 m imum Smart ync h rn-o ap ances Strobe Control NAC Input Current Output NAC current, plus 30 mA @ 24 VDC f r S M operating power Horn Control NAC Current 4 mA @ 24 VDC Class A Operation Mounting Requirement N 44akt SCjwithi20 ft J6 m) ct,ontr , use metal conduit - 4905-9914 & 4905-9922 Synchronization Modules Input Voltage Range 1 16 VDC to 33 VDC 2 A maximum output; requires 5 mA for power Output Ratings Up to 35 maximum strobes per synchronized circuit Mount in control panel or separate 4" (51 mm) square electrical box, 1-1/2" (38 mm) minimum depth 54905-0003-2 9/2004 ski [of M.-MINTIZEMMM çtrol Pane Is/ NAC_Source Available Output ModLdei Required/Function 4010 Series Fire Alarm Control Class A or Class B Strobe Synchronization NA Panels Class B SmartSync Operation 4905-9938 for Class A SmartSync operation 4006, 4008, and 4100U Series Class A or Class B Strobe Synchronization NA Fire Alarm Control Panels Class A or Class B SmartSync operation NA Model Series 4003, 4004, 4005, Conventional reverse polarity NACs, 4100, 4120, 4020, 4001, & 4002 additional modules are required to control Control Panels; 2190 Series synchronized strobes and/or SmartSync Signal ZAMs; 4009 Series appliances Conventional NAC Extenders Class A or B Strobe Synchronization 4009 IDNet NAC Extenders I Class B SmartSync Operation 4905-9914 for Class B synchronized strobes 4905-9922 for Class A synchronized strobes 4905-9938 for SmartSync control NA 4905-9938 for Class A SmartSync operation Module Reference [Moule" Descnphon - - -- 4905-9938 SmartSync Control Module, provides Class A or Class B SmartSync operation 4905-9914 Class B Strobe Synchronization Module 4905-9922 1 Class A Strobe Synchronization Module - Compatible Appliance Reference Appliance Type - Wall mount; selectable for SmartSync Horn operation 4901-9820 Module Reference 4905-9938 Strobes Wall mount; synchronized; also SmartSync compatible 4904-9331 4904-9342 4906-9101 4905-9914 4905-9922 4905-9938 4904-9332 4904-9343 4906-9103 4904-9333 4904-9344 Ceiling mount; selectable for synchronized flash; also SmartSync compatible 4904-9183 4904-9345 49069102 4904-9184 4904-9346 4906-9104 4904-9185 AN Horn/Strobe Wall mount; horn and strobe can be wired separately (4-wire); strobes are selectable for synchronized flash 4903-9425 4903-9427 4903-9432 4905-9914 4905-9922 4903-9426 4903-9431 4903-9433 Wall mount; SmartSync operation only (2-wire) (2-wire) 4903-9331 4903-9342 4906-9127 4905-9938 4903-9332 4903-9343 4906-9129 4903-9344 Ceiling mount; SmartSync operation only (2-wire) 4906-9128 4906-9130 Rectangular case wall mount; horn and strobe can be wired separately (4-wire); strobes are selectable for synchronized flash 4903-9252 4903-9257 4903-9256 4905-9914 4905-9922 4903-9253 4903-9258 4903-9254 4903-9255 SN Speaker/Strobe Wall mount; strobes are selectable for synchronized flash 4903-9356 4903-9359 4906-9151 4905-9914 4905-9922 4903-9357 4903-9360 4906-9153 4903-9358 4903-9361 ___________ Ceiling mount; strobes are selectable for synchronized flash 4903-9196 4903-9198 4906-9154 4903-9197 Rectangular case wall mount; strobes are selectable for synchronized flash 4903-9148 4903-9150H 4903-9194 03-9149 4903-9153 4903-9195 03-9150 F49 _______ 4903-9193 *Bolded PlDs are Multi-Candela products. ** Modules listed are required if control panel NAC or NAC extender does not provide either synchronized strobe output or SmartSync control output as required for proper appliance operation. 3 S4905-0003-2 9/2004 SCM Installation Reference - Mounting Box (by others): Square box, 4" (102 mm), required depth depends on total conductor requirements Minimum depth = 2-1/8" (54 mm), RACO 232 or equal 4" square cover plate, RACO 752 or equal Extended depth (for maximum (by others) conductors), add 1-1/2" (38 mm) extension ring, RACO 201 or equal Tyco, Simplex, the Simplex logo, TrueAlert, and SmartSync are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. 93 Tyco Safety Products Westminster. Westminster, MA - 0144 1-0001 • USA S4905-0003-2 9/2004 .Simplex www.tycosafetyproducts-usa-wm.com © 2004 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:235 Page 1 of 1 CATEGORY: Fire Alarm Device for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Models "TrueAlert non-addressable " 4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable " 4904-9168, 4904-9171, 4904-9169, 4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904- 9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904- 9360, 4909-9361 synchronized strobe lights. Model 4905-9938 sync control module. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, *..9353 -9356, *..9359 -9168, -9171: 15cd, 1 Hz. 4904-9332, 9343 *..9351 *..9354 *..9357 *9360 -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, *9352, 9355, *9358, -9361: 110cd, 1 Hz. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. *corrected 03-04-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 5Simplex TrueAlert® Multi-Candela Notification Appliances UL, ULC Listed; Visible Notification Appliances with Horn and Synchronized FM Approved* Flash; Non-Addressable, SmartSyncTM Operation Compatible In- k'it*u Audible/visible (NV) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair Horn control that can be selected to be temporal coded, march time coded, or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938 Class A (Style Z) operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs Wall mount A/Vs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich output sound suitable for either coded or steady operation UL listed to Standard 464 o L FIRE. F 1,13 III' Wall and Ceiling Mount A/Vs Dfscrintic Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. lntnsitv Slefie During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product was not approved by CSFM or MEA (NYC) as of document revision date. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. S4906-0002 4/2004 Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117. 1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). UIiTT1T Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. fl7iuT1i SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." SmartSync Control Sources 4100U and 4010 Fire Alarm Control Panels (refer to data sheet S4010-0001 for details; refer to data sheet S4100-0031 for basic 4100U information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-993 8 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela A/Vs Mode-1 M;7u—nti 4906-9127 Wall 4906-9129 Ceiling Red White White Red Red White White Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire control 17WMdfl9 NV Adapters_______ ______ D ______- ion -- - Dimensions escript 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 5-3/8"Hx5-1/4"Wx1-5/8"D (136 mm x 133 mm x 41 mm) 4905-9940 White surface mounted boxes depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8"x5-1/8'x2-3/4' D (200 mm x 130 mm x 70 mm) SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Descriphon Dimensions 4905-9992 Red cover with white "FIRE" lettering 5-1/8" H 5" W 1-1/2" D 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions - 49059961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 49059927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mm x_156mmx76mm) 49059928* I Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" I Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4" x 6-7/8' x 1-1/2" deep, 4905-9916 Red 1-1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) * UL listed by Space Age Electronics Inc 2 S4906-0002 4/2004 VVAY&.1TilTTh.iij Wall Mount or Ceilinq Mount. Common SDecifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 VDC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAG Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Horn Output Ratings Sound Type (see Note 2) © 10 ft (3 m) Reverberant Chamber, UL 464 Test Steady Coded Steady Coded Steady Coded 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 3 below) .15cd .' 30 c '. 75 c 110cd 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC. at other voltages 24 VDC 70 mA lolrmA 184 mA 243 mA 60 mA 84 mA 143 mA 185 mA Housing Dimensions with lens) 4-3/4 L" x 6-7/8" W x 2-5/8" D (121 mm x 175 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 Cd 30cd 75 Cd 110 Cd 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC at other voltages 24VDC 81 mA 119 mA 216 mA 70 mA . 97. mA 167 mA 217.mA. NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAG under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) I1fllFUT&1 ](c]Ij*jThI*Z.].flTj1! rr1r1rrnrnTI çTh Th Mounting is compatible with single gang, double gang, and _____ ___ 4"(lO2 mm) square boxes, 1-1/2" (38 mm) deep, by others '7 jo TME Mounting Holes: \ 4" square (4) - \ Single gang (2) -\. Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; - - factory selling is 15 cd Removable cover Strobe Intensity' (tool required) viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, orslightly above bottom of compatible boxes r;=e 7 NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80' and not greater than 96' above the finished floor S4906-0002 4/2004 Wiring access hole Wiring terminals for SmartSync operation 45 Box I Ceiling Mount AN and Guard Installation Reference - Ceiling reference, 4" (102 mm) square box, surface mounted box / 1-1/2 (38 mm) minimum depth C Ceiling reference, flush mounted bo: Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are located behind the housing Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side - Optional 4905-9927 Red Wire Guard End View / Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd -------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt - 0 4905-9931 Adapter Plate 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mout nd box show 4" (102 mm' squ box profile,1 (38 mm) d Optional 4905-9961 Wire Guard --7 Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco, Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSync are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). USimplex Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4906-0002 4/2004 .www.tycosafetyproducts-usa-wm.com 02004 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:317 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4906-9127, 4906-9129 wall mount and Models 4906-9128 and 4906-9130 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation Instruction Manual for details. 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager SirnplexGrinnell LP tqca 'Fire & /SimplexGrinneii 9855 Carroll Canyon Road San Diego, CA 92131 /Fire Tele: (858) 740-0100 Fax: (858) 740-0156 www.simploxgrinnell.com APPENDIX ITEM DESCRIPTION A BUSINESS LICENSE B WARRANTY 12/8/2005 REV.#: 0 PROJECT #: 480-401977-05 SimplexGrinnell LP tqca /Fire & /SimplexGrinneii 9855 Carroll Canyon Road San Diego, CA 92131 I Security Tele: (858) 740-0100 Fax: (858) 740-0156 www.simpiexgrinnell.com Contractor License # 802591 * * * Business Information * * * SIMPLEX GRINNELL L P 6952 PRESTON AVE STE A LIVERMORE, CA 94550 Business Phone Number: (925) 273-0100 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2005 * * * License Status * * * This license is current and active. All information below should be reviewed. * * * Classifications * * * ff Description C1O ELECTRICAL FIRE PROTECTION C16 CONTRACTOR * * * Certifications * * * I Description Rr ASBESTOS - (for bidding purposes only) * * * Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 81880913 in the amount of $10,000 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2004 Contractor's Bonding History BOND OF QUALIFYING 1IND1VJDUAL(1): This license filed Bond of Qualifying Individual number 81880915 for RONALD GILBERT MAYLE in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 BOND OF QUALIFYING INDIVIDUAL(2): This license filed Bond of Qualifying Individual number 81880914 for FRANKLIN MICHAEL BROWN in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 * * * Workers Compensation Information * * * This license has workers compensation insurance with the AMERICAN HOME ASSURANCE COMPANY Policy Number: RMWC6610498 Effective Date: 10/01/2005 Expire Date: 10/01/2006 tqco IF/re & I Security l SimplexGsinnell Sirnp!exGrinne!I LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. WARRANTY SERVICE HOURS: 8:00 AM TO 5:00 PM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST.