HomeMy WebLinkAbout2525 EL CAMINO REAL; ; FS960011; Permit11/21/24, 9:33 AM FS960011 Permit Data City of Carlsbad FIXED SYSTEMS PERMIT 2525 EL CAM INO Job Address: REAL Permit Type: FIXSYS Parcel No: 1563020900 Lot #: 0 Reference No.: Permit No: F5960011 Status: ISSUED Applied 5/14/1996 Approved: 5/15/1996 Issued: 5/15/1996 PC #: Inspector: Project Title: REMD KIT., ADD RANGE HOOD, REMOVE/ADD WALL HOOD & DUCT Applicant: Owner: DUSTY HATFIELD/ALTERNATIVE PLAZA CAM INO REAL 3420 UNIVERSITYAV SAN DIEGO CA. 619-280-8295 Fees ($) Add'l Fees ($) Total ($). Balance ($) 80 0 80 0 about:blank • 1/1 Chapter 3—System Desigr S Page 3- Rev. CHAPTER III System Design f(4 oô(( This section will cover the proper design of the Pyro Chem Res- taurant Fire Suppression System. It is divided into four (4) sections: Nozzle Coverage and Placement. Cylinder Sizing. Piping Limitations. Detector Requirements. Each of these sections must be completed before attempting any installation. SECTION 1 Nozzle Coverage and Placement This section will provide guidelines for determining nozzle type, positioning, and quantity for duct, plenum, and appliance protection. A. Duct Protection The following three (3) nozzles have been developed for the protection of exhaust ducts: Model NL-R Model NL-D2. Model NL-D3. Each nozzle is approved for use with the exhaust fan dampered, undampered with -tfie fan on, or undampered with the fan off. It is not required that the fan be shut down or the exhaust duct be dampered for the system to operate properly. Each nozzle is approved to protect exhaust ducts of unlimited length. 1. Model NL-P. The Model NL-P nozzle is a one (1) flow point nozzle designed for the protection of exhaust ducts. One (1) or two (2) Model NL-P nozzles can be used on a single duct branch. A single Model NL-P exhaust duct nozzle can protect a square or rectangular duct with a maximum perimeter of 50 inches and a maximum one-side length of 17 inches. It can also protect a round duct with a maximum circumference of 50 inches and a maximum diameter of 16 inches (see Figure 3-1). The nozzle must be installed on the centerline of the duct and aimed directly into the duct opening (see Figure 3-2). Two (2) Model NL-P exhaust duct nozzles can protect a square or rectangular duct with a maximum perimeter of 84 inches and a maximum one-side length of 34 inches. They can also protect a round duct with a maximum circumference of 84 inches and a maximum diameter of 26.5 inches. When two (2) Model NL-P nozzles are used to protect a single duct, the cross sectional area of the duct must be divided into two equal symmetrical areas. The nozzle must then be installed on the center line of the area it protects and aimed directly into the duct opening (see Figure 3-2.1). Model NL-D2. The Model NL-D2 nozzle is a two (2) flow point nozzle designed for the protection of exhaust ducts. Only one (1) Model NL-D2 nozzle can be used on a single duct branch. A single Model NL-D2 exhaust duct nozzle can protect a square or rectangular duct with a maximum perimeter of 75.5 inches and a maximum one-side length of 25 inches. It can also protect a round duct with a maximum circum- ference of 75.5 inches and a maximum diameter of 24 inches (see Figure 3-1). The nozzle must be installed on the centerline of the duct and aimed directly into the duct opening (see Figure 3-2). Model NL-D3. The Model NL-D3 nozzle is a three (3) flow point nozzle designed for the protection of exhaust ducts. One (1) or two (2) Model NL-D3 nozzles can be used on a single duct branch. A single Model NL-D3 exhaust duct nozzle can protect a square or rectangular duct with a maximum perimeter of 100 inches and a maximum one-side length of 33 inches. It can also protect a round duct with a maximum circum- ference of 100 inches and a maximum diameter of 31.75 inches (see Figure 3-1) The nozzle must be installed on the centerline of the duct and aimed directly into the duct opening (see Figure 3-2). Two (2) Model NL-D3 exhaust duct nozzles can protect a square or rectangular duct with a maximum perimeter of 150 inches and a maximum one-side length of 66 inches. They can also protect a round duct with a maximum circumference of 150 inches and a maximum diameter of 47.5 inches. When two (2) Model NL-D3 nozzles are used to protect a single duct, the cross sectional area of the duct must be divided into two equal symmetrical areas. The nozzle must then be installed on the centerline of the area it protects and aimed directly into the duct opening (see Figure 3-2.1). NL-P M-02 M-D3 3 (37LX) 2L+2W-5OMAX a+2W-75SMAX X).+2W100MAX I I Li I I Li Lii LI ..-L 425 MAX) - L-L 33 MAX) HrJ HrJ il.. X).5 MAX -4-- -()-- —4- l8S MAX -4-----1- 25 MAX MAX 18.5 MAX -....-2 -4 Figure 3-1. Duct Nozzle Coverage Limitations. ULEX 3830 November 1, 1994 hapter 3w-System Design age 3-2 ev.1 Figure 3-2. Single Nozzle Placement In Duct. 4 MAX I5X MAX Figure 3-2.1. Dual Nozzle Placement In Duct. MAXIMUM MAXIMUM NOZZLE SIDE PERIMETER FLOW POINTS NL-P 17" 50" 2xNL-P 34" 84" 2 NL-D2 25" 2 NL-D3 33 ioo" 2xNL-D3 66" 150' r NOTE: A SINGLE DUCT BRANCH CAN ONLY SUPPORT. A Single NI-P A Single NI-D2 A Single NL-D3 Two NL-P's Two NL-D3's B. Plenum Protection The Model NL-A nozzle is a one (1) flow point nozzle that 61 MAX XX' MAX has been developed to protect the plenum section of the exhaust hood. Only one (1) Model NL-A nozzle can be used on a single plenum branch. A single Model NL-A can protect a plenum (with single or V-Bank filters) with rectangular dimensions of 8 x 4' or less. Larger plenums can be protected by dividing the hazard area so that each nozzle protects an area of 8' x 4 or less (see Figure 3-3). The nozzle(s) must be located at the center of the V-Bank width or centered between the filter width when used with a single bank filter plenum. It must be within 4 of the wall it is mounted against (see Figure 3-4), or within 4" of the edge of the protected zone. ) MAX Duct Nozzle Coverage Chart 'SS MAX 00 MAX Figure 3-3. Plenum Coverage Limitations, Model NI-A Nozzle. JLEX 3830 Jovember 1, 1994 7Pyr Pre-Engineered Fire Number 95-005 .- Date:6-23-95 To: Authorized Pyro Ch&n Restaurant Pre-Engineered Fire Suppression System Distributors. Pyro Chem has developed two new nozzles for protecting range tops. They may be used in addition to the range top' protection currently q.iaIified for the PCL-Series systems. A. The Model NL-RH2 is a two (2) flow point nozzle that can be used for range top protection. The maximum range top area that can be protected by a single NL-RH2 nozzle is 28" by 28. The nozzle must be located within 5 of the center of the protected zone and aimed at the center of the protected zone. The nozzle must be mounted 32 to 45 above the cooking surface. Øiary Note: Nozzle must be located anywl within the shaded area and aimec 11 center of the protected zon. Enclosed with this bulletin is Revision 2 of Page 3-4a and Page 3-4b of the Technical Manual which illustrates this coverage. This new page can be inserted in the Technical Manual for easy reference by removing and discarding Revision 1 of Page 3-4a. All other system parameters and limitations are listed in the Technical Manual. Nqte: Any branch that utilizes the NL-RH2 for range top protection must comply with the limitations listed in the Technical Manual for an Appliance Branch of the appropriate number of nozzles on the branch (one; two, or three). Four nozzle range branch piping Pyro Chem, Inc. 8005261079 - 301 Division Street 201.3359750 Boonton, New Jersey 07005 FAX 201.3350253 p 2. Griddle Coverage. The Model NL-R nozzle is a one (1) flow point nozzle that is used for griddle protection. The maximum griddle area that can be protected by a single NL-R nozzle is 30' x 30". The nozzle must be located over the griddle cooking surface, no more than six (6) inches from the edge of the protected zone. The nozzle must be aimed at the center of the protected zone. The nozzle must be mounted 24" to 50" above the cooking surface. See Figure 3-7. NOTE Nozzle shall be located anywhere in the shaded area and aimed at the center of the protected zone. Figure 3-7. Model NL-R Nozzle Placement, Griddle. 54- 1 INC Figure 3-8. Model NL-F2 Nozzle Placement, Deep Fat Fryer. LONGEST SIDE If SHORTEST SIDE Figure 3-8.1. Model NL-F2 Nozzle Aiming. LONGEST SIDE apter 3—System Design ge 3-4 VA Nozzle Height: The nozzle must be mounted 40" to 500 above the cooking surface. b. Nozzle Aiming. The tip of the Model NL-F1.25 nozzle has two flat areas designed to assist aiming. The nozzle must be positioned so that these flat areas are parallel to the longest side of the protected zone. See Figure 3-6. The tip of the Model NL-F2 nozzle has two flat areas designed to assist aiming. The nozzle must be positioned so that these flat areas are parallel to the longest side of the protected zone. See Figure 3-8.1. NOTE Nozzle shall be located anywhere in the shaded area and aimed at the center of the protected zone. 3. Deep Fat Fryer Coverage. The Model NL-F2 nozzle is a two (2) flow point nozzle that is used for the protection of a single vat of a deep fat fryer. The maximum area that can be protected by a single NL-F2 nozzle is: Cooking Area: 14.75" x 14.00" Integral Drip Board: 14.75" x 7.5' The nozzle must be located over the cooking surface and aimed at the center of the protected zone. The nozzle must be mounted 30" to 50" above the top surface of the deep fat fryer (see Figure 3-8). LEX 3830. ovember 1, .1994 Chapter 3- System Desk' Page 3- 3.1. Deep Fat Fryer Coverage. The Model NL-F2 nozzle isat o(flowpoint nozzle that is used for the protection of a single vat of a deep fat` fryer. The maximum area that can be protected by a single NL-F2 nozzle is: Cooking Area: 18" x 18" Integral Drip Board: 1.8" x 9.75" The nozzle must be located within 11.875" of the center of the longest side, and within 7" of the center of the shortest side 01 the cooking surface and.aimedatthe center of the protected. zone. • The nozzle must be mounted 30" to 42" above .thetop surface of the deep fat fryer (see,Flgure 34.Z). The tip of the Model NL.-F2 nozzle has two fiat areas designed to assist aiming. The nozzle must be positioned so that these flat areas are parallel to the Iongst side of the protected zone. See Figure 3-8.1.' N)T Nozzle shall be located anywhere in the shaded area and aimed at the center of the protected zone. NOTE For installations that require the use of the Model NL-F2 nozzle to protect a deep fat fryer in accordance with Deep Fat Fryer Coverage 3.1 shown here (See Figure 3-8.2), the following additional restrictions apply to the main supply line piping: Minimum length, linear: 8 feet Miminum length, equivalent: 14.1 feet Minimum system.f low points: 4 Minimum branches (total): 3 2775" ?'c— ,- >n-<-.. -'.--. ir INTEGRAL OF FAN COOKING,,' AREA Figure 34.2. Model NL-F2 Nozzle Placement, Deep Fat Fryer. ULEX 38Z June 1, 1 BE NOTE Nozzle shall be located anywhere in the shaded area and aimed at the center of the protected zone.: 0° Figure 3-10. Model NL-F2 Nozzle Placement, Synthetic Rock Charbroiler. 6. Natural Class "A" Charbroiler Coverage. 0 naper i—ysem LJeSl9fl Page 3-5 Rev.1 4. Radiant Charbroiler Coverage. NOTE A radiant charbroiler is distinguished by the use of gas or electrically heated metal strips (radiants) that are used for cooking. The Model NL-R nozzle is a one (1) flow point nozzle that is used to protect either gas or electrically fueled radiant charbroilers. The maximum area that can be protected by a single NL-R nozzle is 25° x 25°. The nozzle must be located over the cooking surface and aimed at the center of the protected zone. The nozzle must be mounted 24" to 50" above the cooking surface. See Figure 3-9. depth shall not exceed two (2) layers of lava, pumice, or synthetic rocks. The maximum area that can be protected by a single NL-F2 nozzle is 25" x 25". The nozzle must be located over the cooking surface and aimed at the center of the protected zone. The nozzle must be mounted 30" to 50" above the cooking surface (see Figure 3-10). The tip of the Model NL-F2 nozzle has two flat areas designed to assist aiming. The nozzle must be positioned so that these flat areas are parallel to the longest side of the protected zone. See Figure 3-8.1. NOTE Nozzle shall be located anywhere in the shaded area and aimed at the center of the protected zone. Figure 3-9. Model NL-R Nozzle Placement, Radiant Charbroiler. 5. Synthetic Rock Charbroiler Coverage. NOTE Asynthetic rock charbrôiler is distinguished by the use of Java, pumice, or synthetic rocks that are used for cooking. The Model NL-F2 nozzle is a two (2) flow point nozzle that is used for the protection of either gas or electrically fueled synthetic rock charbroilers. The maximum fuel NOTE A Class "A" charbroiler is distinguished by the use of charcoal, mesquite chips, chunks, and/or logs that are used for cooking. The Model NL-A nozzle is used for the protection of Class "A" charbroilers with a maximum fuel depth of six (6) inches. The maximum area that can be protected by a single NL-A nozzle is 20° x 24°. The nozzle must be located over the cooking surface and aimed at the center of the protected zone. The nozzle must ULEX 3830 November 1, 1994 Chapter 3—System DesiCr Page 37 Re Figure 3-13. Model NL-UB Nozzle Placement, Closed Top Chain Broiler. b. Open Top Chain Broiler Coverage. The Model NL-A nozzle is a one (1) flow point nozzle that is used for open top chain broiler protection. The maximum area that can be protected by an NL-A nozzles is 32" x 34". The nozzle must be located over the opening and aimed at the center of the protected zone. The nozzle must be mounted 10" to 22" above the cooking surface. See Figure 3-14. 9. Wok Coverage. The Model NL-R nozzle is a one (1) flow point nozzle that is used for wok protection. A single NL-R nozzle can cover a single wok of 14" to 24" in diameter. The nozzle must be mounted 40" to 50" above the cooking surface at a radius of 12" from the center of the wok, regardless of wok diameter. The nozzle must be aimed at the center of the protected zone. See Figure 3-14.1. NOTE Nozzle shall be located anywhere in the shaded area and aimed at the center of the protected zone. 24 Dia, - 241 Dia. Max. -,. I iO 40" NOTE Nozzle shall be located anywhere in the shaded area and aimed at the center of the protected zone. Figure 3-14.1. Model NL-R Nozzle Placement, Wok. Figure 3-14. Model NL.A Nozzle Placement, Open Top Chain Broiler. ULEX 383( November 1, 199 Figure 3-12. Model NL-UB Nozzle Placement, Upright Broiler. 8. Chain Broiler Coverage. Two types of chain broilers are commonly used; open and closed top. Each is protected in a different manner. a. Closed Top Chain Broiler Coverage. The Model NL-UB nozzle is a one-half (V2) flow point nozzle that is used for closed top chain broiler protection. Two (2) Model NL-UB nozzles are commonly used for this application. The purpose of using two nozzles is to distribute the chemical evenly between the cooking surface (on top) and the drip pan (below). For closed top chain broilers that have no drip pan, a single Model NL- UB nozzle can be used. The maximum area that can be protected by a pair of NL-UB nozzles (or a single NL-UB nozzle when no drip pan is present) is 30" x 34". One nozzle must be positioned in the front entrance of the broiling chamber and aimed at the diagonal corner. The nozzle will be positioned above the cooking surface. The second nozzle (if necessary) must be installed above the front edge of the grease drip pan and aimed at its midpoint. See Figure 3-13. Chapter 3—System Design Page 34 Rev., be mounted 15" to 35" above the cooking surface. See Figure 3-11' NOTE Nozzle shall be located anywhere in the shaded area and aimed at the center of the protected zone. S. Figure 3-11. Model NL-A Nozzle Placement, Class A" Charbroiler. 7. Upright Broiler Coverage. The Model NL-UB nozzle is a one-half (1/2) flow point nozzle that is used for upright broiler protection. Two (2) Model NL-UB nozzles are commonly used for this application. The purpose of using two nozzles is to distribute the chemical evenly between the cooking surface (on top) and the drip pan (below). For upright broilers that have no drip pan, a single Model NL-UB nozzle can be used. The maximum area that can be protected by a pair of NL-UB nozzles (or a single NL-UB nozzle when no drip pan is present) is 30" x 34". One nozzle must be positioned in the front entrance of the broiling chamber and aimed at the diagonal corner. The nozzle will be positioned above the cooking surface. If necessary, the second nozzle must be installed above the front edge of the grease drip pan and aimed at its midpoint. 'See Figure 3-12. ULEX 3830 November 1, 1994