2525 EL CAMINO REAL; ; FA050087; Permit
11/21/24, 2:18 PM FA050087 Permit Data City of Carlsbad Fire Alarm Permit 2525 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 1563020900 Lot #: 0 Reference No.: Permit No: FA050087 Status: APPROVED Applied 9/20/2005 Approved: 9/20/2005 Issued: 9/20/2005 PC #: Inspector: Project Title: PAPAYA CLOTHING FIRE ALARM INSPECTIONS Applicant: SIMPLEX GRINNELL 9855 CARROLL CANYON RD SAN DIEGO CA 858-740-0100 Owner: PLAZA CAM INO REAL C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 55 0 55 0 about:blank 1/1 I' IFi re & Scurity SimplexGrinnell SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM PRODUCT SUBMITTAL PROJECT: Papaya Clothing Plaza Camino Real Space #260 2525 El Camino Real Carlsbad, CA 92008 te AROVEO /) APPROVED AS NOTED NOT APPROVED, RESUBMIT CHECKING IS ONLY FOR COFORMAN WITH THE DESiGN CONCEPT uF THE PROJECT AND COMPLIANCE WITH THE INFORMAHON GIVEN IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE IIR [NAEHSIONS TO BE CONFIRMED D CORRELATED AT THE JOB SITE AND FOR COORDINATION Of AlE WORK OF ALL TRAD 8/31/2005 REV.#: 0 PROJECT #: 480-402025-01 tqcci lFire & / SimplexGrinnell Security SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM ITEM QTY MODEL NO. DESCRIPTION C.S.F.M. NO. A 1 4004-9101 Fire Alarm Control Panel 7165-0026:213 2 2081-9272 6.2 AH Battery N/A B 8 4098-9788 2 Wire Base with LED 7300-0026:222 8 4098-9601 Photoelectric Smoke Detector 7272-0026:219 C 1 4090-9101 Monitor ZAM(Ties to Mall System) 7300-0026:223 D 1 4905-9938 Sync Module 7125-0026:235 E 1 4906-9130 Horn/Strobe Only Multi-Candela 7125-0026:317 8/31/2005 REV.#: 0 PROJECT #: 480-402025-01 935implex UL Listed FM, CSFM, and NYC, MEA Approved* STANDARD FEATURES Two initiating device circuits (lDCs): - Style B (Class B), expandable to eight - Five programmable operation modes - Internal DACT (standard 4004-9101 & -9102) - Service Disconnect and Alarm Verification are selectable per zone - Fifteen second "Abort Enable" Two Style Y (Class B) notification appliance circuits (NACs): - Up to four (4) amps, two amps each NAC - General alarm operation - Each selectable for on-until-silence or on-until-reset operation - Five coding options - Programmable alarm cutout - Common disconnect switch for circuit disable Compatible with: - Simplee 4003 Voice Control Panels, 4009 NAC Power Extenders, and 4601 Series Remote LED and LED/Switch Annunciators Panel features and operation: - Two, seven segment LED status and diagnostic displays - Selectable alarm silence/reset inhibit - Power limited design - Dedicated supervisory status and alarm silenced status LEDs - Selectable active status reminder - WALKTESTTm performance testing** - Auxiliary outputs for alarm, supervisory, and trouble Single chassis assembly with large wiring terminals for easy wiring Easy semi-flush or surface installation: - Semi-flush mount between 16" stud centers - Built-in trim plate for semi-flush mounting - Drywall alignment tabs and nail knockouts - Beige or red cabinet Optional features: - Remote Station/City Connection - Style D/Style Z (Class A), two circuit zone conversion module - Multi-purpose annunciator interface - Internal and remote relay modules NOTE: Contact your local Simplex product supplier for fire alarm control panels suitable for Release Control applications. LifeAlarm® Fire Alarm Controls Fire Alarm Controls 4004 Series Fire Alarm Control Panels; Two to Eight Zones 4004-9101 Fire Alarm Control Panel (shown with zone labels applied) INTRODUCTION Simplex 4004 Series fire alarm control panels provide easy installation, flexible initiating circuit monitoring, and extensive programmable control capability for areas requiring two to eight IDC zones. Installation ease has been considered throughout, from cabinet design to quick and easy setup. By employing surface mount components, seven segment LEDs, and efficient microprocessor programming, an extensive feature list is provided in a cost-effective and compact package. Panel status is efficiently indicated by discrete LEDs and an alphanumeric zone indicator/diagnostic display. Panel control switches are clearly marked for easy operation. Programming of the selectable features is quickly performed using the LED display and the panel control switches. APPLICATIONS The 4004 Series fire alarm control panel provides protection for a wide variety of smaller facilities in the following fields: Educational, Health Care, Business, Storage, Hospitality, Residential, and General Assembly. Due to its modular construction, the 4004 can be ordered with only the features needed. If the system expands, then additional modules (up to eight zones) can be easily installed on-site. ** WALKTEST performance testing is protected under US Patent No. 4,725,818. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:213 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. This product was not ULC listed as of document revision date. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. S4004-0001-6 7/02 4004 Display/Control Panel CONTROL PANEL FEATURES Alarm Indication Upon receiving an alarm, the Fire Alarm Zone LED displays the number of the alarmed IDC. If multiple IDCs are in alarm, each number will alternately be chronologically displayed. During this time, the internal tone-alert signal will be sounding and the NACs will be operating as programmed. Alarm Silence To silence the alarm, the "ALARM SILENCE" switch is momentarily pushed and the "ALARM SILENCED" LED will light. Repeated use of the "ACK" switch will scroll through the alarmed zone numbers in chronological order. Supervisory or Trouble Conditions Supervisory conditions are for monitoring devices such as waterfiow tamper switches - conditions more serious than a trouble, but not considered an alarm. Troubles include open, shorted, or earthed wiring, AC power loss problems, or other indications (refer to trouble list below). The trouble type is displayed alphanumerically on the LED digits using upper and lower case letters and the period. LED Trouble Identification List IDC Zone Number IDC Auxiliary Output Annunciator Card Trouble Supervised Auxiliary Alarm Output Trouble Battery Low Trouble City Circuit Trouble Configuration Trouble Depleted Battery Trouble NAC I Trouble NAC 2 Trouble WALKTEST Enabled (System is in WALKTEST "Trouble") Program Trouble Power Supply Trouble Ground Fault Trouble Supervisory Condition Indication Supervisory conditions are annunciated by flashing the yellow Supervisory LED and activating the tone-alert and the common supervisory output. Supervisory zones are numerically displayed on the red Fire Alarm Zone indicator LED display with a decimal point identifier. Using the ACK switch will scroll the zone numbers chronologically. Alarm Acknowledge Momentarily pressing the "ACK" switch will acknowledge the alarm condition and will silence the local tone-alert signal. Supervisory Acknowledge During Supervisory conditions, the yellow SUPERVISORY LED will stop flashing and remain "on" until the condition is cleared and the panel is reset. Trouble Acknowledge During Trouble conditions, the yellow TROUBLE LED display identifies the specific trouble(s), chronologically scrolling through multiples troubles. Multiple Battery Status Monitoring Batteries are monitored for both presence and proper charging. Additionally, in the event that battery operation extends beyond the available battery capacity, a depleted battery trouble signal will warn when the battery charge is approaching depletion. WALKTEST Performance Testing Simplex WALKTEST performance testing allows a single fire alarm system tester to manually initiate remote troubles and alarms and obtain a verification output from the NACs with an automatic Reset. Alarms are initiated to produce a zone identifying pulse count. With the zone number confirmed, troubles can then be initiated and confirmed with a common pulse output. Inside Front Door Information A reference label inside the front door provides extensive information concerning the following. Emergency operating instructions Fire alarm indicators Trouble indicators Site-specific zone descriptions (custom labels) Programming instructions Panel layout and module location Terminal identification for on-site wiring 4004 OPERATION/PROGRAMMING OPTIONS IDC Operation Standard IDCs are low current and support up to 20 Simplex detectors per IDC, 2 mA maximum. (For detectors with relay bases, use high current expansion modules, see chart on page 3). For further information, refer to field wiring diagram 841-992 and Installation Instructions 574-074. IDCs are individually programmable as: Standard Fire Alarm Alarm Verification Fire/Supervisory Trouble Only or for Current Limit Devices Only (Style C) S4004-0001-6 7/02 page 2 4004 PROGRAMMING OPTIONS (Continued) GENERAL OPERATION Selectable Active Status Reminder is available to provide a reminder every 8 hours that an acknowledged condition still exists Common Outputs for Alarm, Supervisory, and Trouble, 24 VDC, 150 mA open collector relay or LED driver; Common Alarm is supervised the same as the Auxiliary Alarm output Internal Dual Line DACT module has automatic 24 hour test and programmable power fail report delay (standard on models 4004-9101 and 4004-9102) NAC OPERATION/FEATURES General Alarm Operation. Standard is NAC 1 On-Until-Silenced (to manually silence audible notification appliances) and NAC 2 On-Until-Reset (maintains visible notification until the system is restored to normal); each can be jumper selected as either type Notification Coding is programmable as: Steady Signaling, Temporal Pattern, March Time @ 20 BPM, March Time @ 120 BPM, or Simple Coding (Simple coding is a repetitive code equal to the zone number that initiated the alarm) Supervised Auxiliary Alarm Output per IDC, 24 VDC, 150 mA open collector driver, current limited, UL listed for Pilot duty; provides auxiliary control and circuit supervision of a compatible annunciator or remote relay for emergency control in accordance with NFPA 72 and NFPA 101 NAC OPERATION/FEATURES (Continued) Signal Silence Inhibit is programmable as: 0, 1, 2, 3, 4, or 5 Minutes (time after alarm occurs that Signal Silence Switch will be intentionally unable to silence alarm) Alarm Silence Cutout is programmable as 0, 10, 20, or 30 minutes (time after alarm when automatic silence occurs) OPTIONAL ON-SITE INSTALLED MODULES Standard Low Current Operation, 2 IDC and 4 IDC modules, for up to 20 detectors per IDC, 2 mA maximum detector power (for detectors without relay bases) High Current Operation, 2 IDC and 4 IDC modules, for up to 30 detectors per IDC, 3 mA maximum detector power (for detectors with relay bases) Dual Circuit City Connection module, selectable as local energy or reverse polarity; Reverse polarity is selectable for Alarm/Trouble, Alarm, Supervisory, or Trouble only reporting (available with or without disconnect switches) Class A (Style D/Style Z), 2 Circuit Adaptor module for either lDCs or NACs Supervised Annunciator Interlace module, 3 inputs (remote Reset, ACK, and Silence), and 4 outputs (Trouble, Supervisory, Alarm Silenced, Remote Sounder), 24 VDC, current limited, 150 mA open collector each Relay Module provides separate dry contact outputs for Alarm, Supervisory, and Trouble; selectable as N.O. or N.C.; rated 2A@ 32 VDC 4004 Model Selection Chart II 'Description Standard Control Panels (4004-9101) Beige Cabinet 120 VAC, 60 Hz I 4004 Fire Alarm Control Panel, Class B Operation, 2 lDCs, 2 NACs, I with 4 A Power Supply I I 40049102* Red Cabinet 4004-9201 Beige Cabinet I 220/240 VAC, 50/60 Hz i 4004-9202 Red Cabinet Expansion Modules 4004-9802 2 Point IDC, Class B I Standard Operation, for detectors without relays Select one maximum 4004-9822 4 Point IDC, Class B I High Current Operation, for detectors with relay bases i~:470704-98 0! Standard Operation, for detectors without relays Select one maximum 4004-9824 High Current Operation, for detectors with relay bases Optional Modules 4004-9806 Class A (Style D/Style Z) Two Circuit Adaptor Five (5) maximum 4004-9808 Annunciator Interface, 3 Inputs, 4 Outputs Select one maximum 40049809* City Connect Module, 2 Circuits, with disconnect switches 40049829* City Connect Module, 2 Circuits, without disconnect switches 40049810* Internal DACT, connects to RJ3IX Telco jacks, requires one DACT cable/line 40049803* Relay Module; Alarm, Supervisory, and Trouble relay Batteries** (2081-9272) 6.2 Ah battery, typical for 24 hour standby, 2 required 174 10 Ah battery, typical for 60 hour standby, 2 required Accessories (select as required) Select one maximum Select one as required 4001-9810 Four alarm relays mounted on a 6 gang plate; coils require 20 mA each at 24 VDC; contacts are rated 1/2 A at 120 VAC, 2 A at 30 VDC, resistive (refer to data sheet S4001-0003) 4601 Series Remote LED and LED/Switch Annunciators (refer to data sheet 84601-0002) 2080-9047 DACT cable with RJ45 plug, 14 ft long (4.3 m), required for DACT use * 4004-9101 and 4004-9102 include a DACT as standard equipment. Operation allows for either a City Connection Module, or a DACT Module, or a Relay Module. 4004-9810 is for aftermarket add-on. The DACT module is programmed using a terminal or a laptop computer in terminal emulation mode. Connection and programming details are provided with the installation instructions (publication 574-049). ** Refer to Field Wiring Diagram 841-992 for battery selection. S4004-0001-6 7/02 page 3 Specifications putPower , 102-132 VAC, 60 Hz 2 A maximum 204-264 VAC, 50160 Hz 1 A maximum Auxiliary Alarm Outputs 150 mA @ 24 VDC, open collector, current limited Common ALM, supv, TBL Resettable Smoke Detector 500 mA @ 24 VDC, open Power collector, current limited Auxiliary Power 2 A maximum @ 24 VDC Alarm, Supervisory, and Trouble 4004-9803 Relay relays, each relay output is rated 2 A maximum @ 32 VDC; selectable as N.O. or N.C. [invfronrnent& Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range 10% to 93% RH, non-condensing @ 90° F (32° C) Mounting Dimensions Module Currents* - ' Module L. •.,, Base Panel, 120 or 240 VAC —Current 52 mA Current 82 mA** 4004-9802, 2 IDC, Low Current 7 mA 38 mA** 4004-9804, 4 IDC, Low Current 14 mA 45 mA** 4004-9822, 2 IDC, High Current 14 mA 86 mA** 4004-9824, 4 IDC, High Current 27 mA 94 mA** 4004-9806, Class A Adapter 0 mA 0 mA 4004-9808, Annunciator Interface Module 4 mA 4 mA + Annun. loads 4004-9809 2 Circuit City Connect Modules 20 mA 36 mA 4004-9829 DACT Module (4004-9810) 30 mA 45 mA 4004-9803 Relay Module 10 mA 37 mA * Note: Add IDC 2-wire detector current and NAC loads for total. Refer to Field Wiring Diagram 841-992 for battery selection and additional detail. ** Conditions: Both NACs on; one IDC in alarm per module, remaining lDCs in supervisory mode. Add NAC loading and 2-wire detector load current per application. Reference, 16' Stud Centers P 1 Box Width = 14-1/2" (368 mm) . .. .. .. N •• •u us us us •. •u .0 us •u •• •• .... au us u.s uu au• .u.•u WE uuuu au •uauu. us I-•• U ••• •• •• •• UU U •• •• •• •..• •.:••• usus uui• WE 55 Width = 15-5/16" (389 mm 0. includes an 0.048" (1.22 mm) thick [ B Box trim for semi-flush mounting. Height and are same as door. Knockouts are I (98 mm) I Two on each side 3-7/8" I provided for nailing. I I and one each on top 1/2" and bottom. (13 mm) Door Height 16-7/8" (429 mm) NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. Tyco, Simplex, the Simplex logo, L(feA/arm, and WALKTEST are trademarks of Tvco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 70 NFPA 72, and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). 5Sirriplex TEPG-US • 91 Technology Drive • Westminster, Massachusetts• 01441-0001 USA S4004-0001-6 7/02 © 2002 TEPG-US (a Tyco company). All rights resented. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:213 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattem (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Mod' od 4004-9101 9102, -9201 and -9202 fire alarm control units. Power-limited, coded, non-co e , cal, local, auxiliary, remote station, proprietary and central station fire alarm service; automatic, manual and waterfiow alarm and sprinkler supervisory service. Refer to listees data sheet for additional detailed product description and operational considerations. System components: 565-573 4004-9802, -9804, -9822, -9824 4004-9806 4004-9809,-9829 4004-9808 2080-9044 4004-9810 2088-9007 System Board Initiating Expander Board Style Z Adapter City Connect Board Annunciator Interlace Board DACT DACT Shunt Module INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as fire control units for use with separately listed compatible initiating and indicating devices. The control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to listees Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature, the maximum Retard/Reset/Restart must be adjusted to 30 sec. or less. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Multi-Application Peripherals 935implex and Accessories Batteries and Chargers 2081 Series System Batteries, 6.2 Ah to 50 Ah FEATURES Rechargeable, sealed lead-acid design: - Lead-calcium grid structure - Immobilized electrolyte in absorbent separator - High reliability dual seal construction - Low maintenance, no need to add water - Low self-discharge characteristics One-piece, high impact polystyrene cell cover LJL 924 recognized pressure relief valves Available in a variety of capacities DESCRIPTION Simplex rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see Figure 1, page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. SPECIFICATIONS Nominal Voltage Rating...............................12 V/battery Discharge Rating.......................................20 Hour Rate Typical Charge/Discharge Cycles .................100 to 150 Preferred Charge Temperature Range . . .60° F to 90° F (15.6° C to 32.2° C) - These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact Simplex for proper battery selection per system requirements. Sealed Lead-Acid Batteries for Panel Mounting APPLICATIONS Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through Simplex Service.) Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. © 2000 Simplex Time Recorder Co. All rights reserved. S2081-0006-15 6/00 Q-1-4 n, .tnr ,%n,nr Cell case (high impact polystyrene) Inner Lead- Absorb used I SEALED LEAD ACID BATTERY CONSTRUCTION DETAILS: (actual appearance will vary with battery size) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator Figure 1. Battery Construction Reference S2081-0006-15 6/00 page 2 BATTERY SPECIFICATIONS AND SELECTION CHART Battery Mechanical Specifications* Battery Model Ah, 20 Hour Rate (Ah) Width Depth Height with Terminals Approximate Weight 6.2 6 1/8" (156 mm) 2 5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 6" (153 mm) 4 1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 6' (153 mm) 4" (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 7 1/4" (184 mm) 33/8" (86 mm) 6 5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 6 5/8" (168 mm) 5" (127 mm) 7" (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular) 33 12 1/2" (318 mm) 3 3/8" (86 mm) 7 1/16" (179 mm) 26.6 lbs (12.1 kg) 2081-9276 (square) 33 7 3/4" (197 mm) 5 1/4" (133 mm) 63/4" (171 mm) 26.5 lbs (12 kg) 2081-9296 50 9 1/2" (241 mm) 5 1/2" (140 mm) 87/8" (225 mm) 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Selection Chart for Fire Alarm Control Panel Mounting Ah, 20 Simplex Control Panel Series (see legend and notes below) Battery Model Rate 4003 4004 4005 4009 4010 40215 014120 (2 4or6Umt) (2 4 o 6-Unit) 2081-9272 6.2 Yes 2081-9274 10 Yes 2081-9288 12.7 Yes Yes Yes Yes Yes 2081-9275 18 Ext Note I 2081-9287 25 Ext F Yes Ext 2081-9271 (rectangular) 33 Note 3 Note 2 Ext 2081-9276 33 Yes (square) Ext 2081-9296 (Note 4) 50 Ext Yes = Can be placed in the respective equipment cabinet Ext = External battery cabinet required, refer to selection chart on page 4 Shaded area = Not applicable NOTES: 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. Refer to individual fire alarm control panel product data sheets for additional battery application information. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact Simplex for proper battery selection per system requirements. S2081-0006-15 6/00 page 3 EXTERNAL BATTERY CHARGER AND CABINET REFERENCE External Battery Cabinets Externally Mounted Battery Battery Cabinets without Chargers Battery Ah Cabinets with Chargers (connects to charger in panel) Model our Rate UO - - 2081-9301— 2081 9303** Series 2081 927O** 2081-9281 2081 9282 4009-9801 4009-9802 - 2081-9275 18 Yes Yes Yes 2081-9287 25 2081-9271 Yes 33 2081-9276 2081-9296 50 Yes * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. Yes = Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specifications Model Description Color Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25 3/4W x 20 3/4" H x 6 3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 2081-9270t External battery cabinet without charger e Red 26 1/2" W X 12" H x 12" D (673 mm x 305 mm x 305 mm) 2081-9301t External battery cabinet with charger 2081-9303t External battery cabinet with charger and with meters for voltage and current 4009-9801 External battery cabinet without For up to 18 Ah 16 1/4" W x 13 1/2" H x 4 1/8" D charger, with solid door and battery harness, for close-nippled mounting batteries Beige (413 mm x 343 mm x 105 mm) 4009-9802 For up to 33 Ah 25 3/4" W x 20 3/4" H x 4 1/8" D to fire alarm control panel cabinet batteries (654 mm x 527 mm x 105 mm) 4081 Companion cabinet and charger for For up to 50 Ah Available in beige I 22 1/2" W x16 3/4" H x 8 3/8" D Seriestt the 4010 fire alarm control panel batteries r (572 mm x 425 mm x 213 mm) t Refer to Simplex data sheet S2081-0002 for additional information. tt Refer to Simplex data sheet S4081-0001 for additional information. Simplex and the Simplex logo are registered trademarks of the Simplex Time Recorder Co. S2081-0006-15 6/00 BSirnpIec Westminster, Massachusetts 01441-0001 U. S. A. Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of pnnting and are subject to change without notice. 5Simplex TrueAlarm® Smoke Detectors UL, ULC Listed; FM, CSFM, TrueAlarm Photoelectric Smoke Detectors and MEA (NYC) Approved* for Two-Wire and Four-Wire Bases Photoelectric smoke detector with on-board TrueAlarm sensitivity drift compensationt UL listed to Standard 268 Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: 4098-9601, Standard Sensitivity, nominal 2.8%/ft obscuration 4098-9605, Special Application Sensitivity, nominal 3.5%/ft obscuration Available base options: Bases for 2-wire or 4-wire operation Auxiliary alarm relay output Optional remote alarm indicating LED I'.z*.Illt1 Simplex® TrueAlarm photoelectric detectors provide many of the proven TrueAlarm analog sensing features for applications where detectors are connected to conventional 2-wire or 4-wire initiating device circuits (lDCs). Each TrueAlarm detector has an on-board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. TrueAlarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high performance smoke capture abilityt. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. 4098-9601 TrueAlarm Photoelectric Detector Mounted in Base Specifications Voltage 15 to 32 VDC from Fire Alarm Control Panel IDC Standby Current @ 24 VDC Alarm Current, 2-Wire I Up to 86 mA maximum, exact curr) Operation determined by alarm current limiting of nected IDC Alarm Current, 4-Wire Operation - 24 mA typical @ 24 VDC Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/mm (0-610 rn/mm) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 15° to 122° F (-9° to + 50° C) Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non-condensing Color Frost White 4-7/8" Dia. x 1-7/8' H, mounted in base Dimensions (124 mm x 48 mm); refer to page 3 for detail * ULC listed models are designated with a "C" suffix such as 4098-9601C. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7272-0026:219 for allowable values and/or conditions concerning material presented in this document. It is Subject to re- examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. t TrueAlarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573. S4098-0015-5 10/02 - Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accumulation of dust and dirt. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. (See page 3.) !!1'1 ITitTi Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke detector spacing of 30 ft (9.1 m) may be used as a guide. For detailed installation information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). Sensitivity Selection. The 4098-9601 standard sensitivity detector is recommended for most applications. When a special application for a reduced sensitivity detector is required, the 4098-9605 should be considered. Consult your local Simplex product supplier for assistance in determining the proper selection. r1imt Slaitir Smoke Detectors [_I Dription - Nominal Sensitivity C iiiy 4098-9601 2.8%/ft (standard) Compatible with bases: 4098-9788, 4098-9682, and TrueAlarm Photoelectric Detector 4o98.96o5 4098-9683 Compatible Bases 4098-9788 2-Wire Base with connections for IDC and LED connections are screw terminals for in/out wiring, Remote Alarm LED Indicator 18 to 14 AWG 4-Wire Base with Auxiliary Alarm Relay Ratings, Single Form "C", For Suppressed Loads: Relay Contacts and connections for Power limited, 3 A @ 28 VDC; Non-power limited, 3 A @ 120 VAC 4098-9682 Remote LED Alarm Indicator Wiring Connections (In/Out where required): NOTE: Requires external 24 VDC for operation Relay contacts and IDC wiring, color coded 18 AWG leads; LED wiring, screw terminals for 18 to 14 AWG 2-Wire Base with Auxiliary Alarm Relay Ratings, Dual Form "C", For Suppressed Loads: Relay & connections for Remote LED Power limited, I A @ 28 VDC; Non-power limited, 1/2 A @ 120 VAC Indicator Wiring Connections (In/Out where required): 4098-9683 NOTE: Must be connected as the only device on the IDC to ensure relay Relay contacts and IDC (-), color coded 18 AWG leads; operation. IDC (+) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories odel -7 LT a Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes 4098-9832 Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098-9788, -9682, & -9683 4098-9830 Remote LED Indicator Mounted on single gang stainless steel plate 2098-9739 Encapsulated Dimensions: 2-1/2" x 1-1/2" x 1" Required for 4-wire circuits using 24 VDC End-of-Line Relay (64 mm x 38 mm x 25.4 mm) 4098-9682 base, one per circuit; select mounting type as required; wiring is Mounted on single gang 2098-9735 Plate Mounted stainless steel plate color coded 18 AWG wire leads * Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm2; 14 AWG = 2.08 mm2 S4098-0015-5 10/02 - LED Inthcation Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * r Followed By - Status Action T LED turns ON Alarm is initiated Normal, sensitivity is within None compensation range LED pulses quickly, 6 times in 3 seconds, Alarm is initiated More sensitive, out of normal then turns ON compensation range Cleaning or other service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required * Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual 574-709 for further test and maintenance information. Dimensions and Reference Information 1/4" (6.4 mm) 6-3/8" (162 mm) 4098-9832 Adapter Plate 4-7/8" (124 mm) "I F- T I Base height 1-7/8" 11/16" I (48 mm) (17 mm) I_lit__I _III LED Status Indicator (with clear lens) 4098-9601 & -9605 Dimensions Mounted on Base ALARM 0 & 4098-9830 Remote LED Indicator (not to scale) 3 S4098-0015-5 10/02 Mounting Information (Electrical boxes are supplied by others.) Electrical Box Requirements: Without (base 4098-9788): 4" octagonal or 4" square, 1-1/2 deep Single gang, 2" deep With relay (bases 4098-9682 and 4098-9683): 4" octagonal, 1-1/2" deep, with 1-1/2" extension ring 4" square, 1-1/2" deep, with 1-1/2" extension ring Surface mount reference 4" (102 mm square box 4" (102 mm) octagonal box 1-1/2" (38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4" (6.4 mm) maximum recess 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and t04" square flush mount boxes 4098-9682 and 4098-9683 include a relay module that mounts in base electrical box Smoke Detector Bases 4098-9788, 9682, & -9683 4098-9601, -9605 Smoke Detector Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). O Sirriplex TEPG-US• 91 Technology Drive• Westminster, Massachusetts" 01441-0001" USA S4098-0015-5 10/02 © 2002 TEPG-US (a Tyco company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:219 Page 1 of 1 CATEGORY: Photoelectric Smoke Detectors LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Mode€96019601TSP, -9602, -96021SP, -9605, -9605TSP; *GsA40989601 *..9602 * 5 photoelectric type smoke detectors. Models 4098-9602, -96021SP; and *GsA4098..9602 employs an integral 1350F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector and not intended for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed system description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with listee's listed Models 4098-9682, - 9683 or -9788 detector bases *(CSFM Listing No. 7300-0026:222) and separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ., ., recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation V criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:222 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Models 4098-9682, 4098-9683 40~ eprOduct nd 4098-9684 detector bases. Refer to listee's data sheet for additional deal description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 5$implex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET Il® or IDNetTM Communicating Devices and MEA (NYC) Approved* 4090-9101 and 4090-9106, Zone Adapter Modules MAPNET II or IDNet communications** compatible Monitor ZAMs (Zone Adapter Modules) provide an addressable interface to a conventional initiating device circuit (lDC) Available for Class B or Class lDCs: 4090-9101, Class B (Style B) monitoring for 2-wire or 4-wire initiating devices, with power reset connections for 4-wire devices 4090-9106, Class A (Style D) monitoring for 2-wire initiating devices Zone device power is supplied separately (typically from fire alarm control panel) Refer to device compatibility list on page 2 Compatible with Simplex: Model Series 4010/4100/4120/4020 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 communicating device transponders (CDTs) equipped with MAPNET H communications Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4" square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 Dcasrrintic MAPNET ll/IDNet Monitor ZAMs allow a single addressable point to monitor a conventional initiating device circuit (DC) populated with 2-wire or 4-wire initiating devices. Refer to page two for compatible devices. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact Simplex for the latest status. MAPNET II and IDNet addressable designs are protected by U.S. Patent 4,796,025. 4090 Series IDNet Relay IAM/ZAM Package (shown approximately 1/2 size) Specifications Communications MAPNET II or IDNet, 1 address per device ZAM Input Voltage 18.9 to 32 VDC (nominal 24 VDC) Supervisory = 16 mA maximum ZAM Current @ 24 VOC Alarm = 72 mA maximum (actual current is determined by total device requirements) 4090-9101 ZAM, Zone 3.3 kQ, 1 W Supervision Resistor Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire Up to 2500 ft (762 m) from fire alarm control panel Up to 10,000 ft (3048 m) total wiring MAPNET II or IDNet Wiring distance (including 1-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 41/8°Hx41/8"Wx1 3/8"D (105 mm x 105 mm x 35 mm) Housing Material Black thermoplastic Mounting Plate Material Sheet metal, galvanized Temperature Range 32* to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) © 2000 Simplex Time Recorder Co. All rights reserved. S4090-0003 8/00 110 Product Selection ZAM Module Model Number Description - - - - ................................................ 91o1 Zone adapter module, for Class B monitoring of 2-wire or 4-wire initiating devices, with power reset connections for 4-wire devices 4090-9106 Zone adapter module for Class A monitoring of 2-wire initiating devices Optional Trim Plates and Mounting Bracket [Model Number Descnption * 4090-9801 For semi-flush mounted box Trim plate with LED viewing window, includes mounting screws 4090-9802 For surface mounted box Monitor ZAM Two-Wire Initiating Device Compatibility Reference Chart ModelNumber Compatible 2098-9209 No base 4098-9401 4098-9402 required 4098-9403 4098-9404 4098-9612 4098-9788 4098-9613 4098-9614 4098-9684 - 4098-9683 4098-9615 Maximum Quantity 20 20 1 20 1 20 1 20 Description Direct connect photoelectric smoke detector Electronic heat detectors Photoelectric smoke detectors Ionization smoke detector Duct detector housing with 4098-9601 detector 4098-9601 4098-9788 4098-9602 4098-9605 4098-9683 4098-9603 4098-9788 4098-9683 4098-9685 N.A. Reference for Existing Equipment - -- - 2098-9201 2098-9211 20 2098-9202 Smoke detectors 2098-9203 2098-9576 2098-9637 1 4098-9407 I I Electronic heat detectors 4098-9408 2098-9211 20 4098-9409 I 4098-9410 I NOTES: Four-wire detector operation is compatible with conventional listed contact closure initiating devices. Four-wire detectors require detector voltage to be connected to resettable power terminals. Refer to installation instructions 574-183, and field wiring diagram 842-073 for additional information. Contact Simplex for additional compatible devices. Simplex Time Recorder Co. 2 S4090-0003 8/00 \ 4" (102 mm) square box, 2 1/8 (54 mm) minimum depth, RACO 232 or equal (supplied by others) 4090-9101/9106 ZAM Double gang blank cover plate and mounting screws, for use when LED is not required to externally viewed (supplied by others) 11 Address setting under resealable label - FEW ZAM Mounting Information Mounting Reference, Double Gang Blank Cover Plate 49/16" (116 mm) © © © © Light pipe for LED viewing 4 5/16" (109 mm) © © © © —4 9/16" (116 mm) PP. 45/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED Simplex Time Recorder Co. 3 S4090-0003 8/00 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:223 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattem (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4090-9001, *..goolTsp *..9001uP and *..9051 Supervised lAM Monitor Module; 4090-9002, *..9002TSp and *..9002uP lAM odule; 4090-9106, *..910615p and 9106TTP Class "A" ZAM Initiating Module, 090-9101 -9IOITSP, and *..g1O1uP Class "B" ZAM Initiating Module; and 2190-9173 Two- oint I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. "Rev. 09-25-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation ' criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager BSimplex UL, ULC Listed; FM, CSFM, and MEA (NYC) Approved* I1(!I1*I Convert conventional Notification Appliance Circuits (NACs) into SmartSync circuits or synchronized strobe circuits: SmartSync Control Modules combine separate horn and strobe NAC inputs into a 2-wire control that can silence horns while maintaining synchronized strobe operation* * Synchronized Flash Modules provide a 2-wire synchronized strobe output that also operates compatible 24 VDC conventional reverse polarity notification appliances* * SmartSync Control Module (SCM) provides two-wire control to separately activate horns and strobes: Operation allows "on-until-silenced" and "on-until-reset" on the same two-wire pair while maintaining supervision continuity SmartSync horns sound as Temporal or March Time pattern, or continuous, controlled separately from strobes on the same circuit Strobes on the same circuit operate at a synchronized 1 Hz flash rate Output is either Class B or Class A Conventional strobe synchronization models: Encapsulated package with color coded wire leads provides 1 Hz strobe synchronization and maintains supervision continuity Conventional horns and other DC appliances operate on the same 2-wire circuit Models are available with Class B or Class A output Small size allows convenient mounting UL listed to Standard 1971 TrueAlert® Notification Appliances SmartSyncTM Control Module and Strobe Synchronization Modules FIN ON a a a a p p NIVd WVd 100 NI I IN flUII1UOV xain ,moa "3 ' NAC 01"A NAC OUT OUT IN 34 4905-9938 SmartSync Control Module (SCM), Shown Approximately 1/2 Size 4905-9922, Class A Synchronized Flash Module, Shown Approximately 1/2 Size Model 4905-9938 SCM (SmartSync Control Module) converts two conventional NAC inputs into a SmartSync two-wire NAC output. One NAC can be programmed to operate as "on-until-silenced" and would be designated as the horn control (non-coded, on continuously during alarm). A second NAC would be programmed to provide "on-until-reset" operation and would be for the visible appliance (strobe) control (also non-coded, on continuously during alarm). Power is supplied by the strobe control NAC. Selectable Horn output and Synchronized * These products have been approved by the California State Fire Marshal (CSFM) pursuant Strobes. In addition to operating the strobe and the horn to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:198 and 7125-0026:235 for allowable values and/or conditions concerning independently, the SCM can be switch selected to operate material presented in this document. It is subject to re-examination, revision, and possible the horns as temporal coded, march time coded cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. (60 beats/minute), or on continuously. Strobes are Additional listings may be applicable; contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of activated with 1 Hz synchronized flashes. Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. S4905-0003-2 9/2004 Multi-Sync Mode. Up to eight SCMs can be interconnected to synchronize system. notification. Interconnected SCMs are supervised for proper circuit connection. The horn input NAC powers the Multi-Sync function. Isolated NAC Inputs. Both NAC inputs are isolated from each other and can be supplied from different control panels. Class B (Style Y) and Class A (Style Z) output operation are both supported. Earth fault detection is provided by the strobe control NAC during supervision mode. Model 4905-9914 and 4905-9922 add the required control to activate Simplex synchronized strobes for NACs that do not provide that control. Conventional horns or other compatible 24 VDC notification appliances on the same circuit ignore strobe synchronization and operate when the NAC is in alarm. For additional information refer to Installation Instructions 579-232. For additional information refer to Installation Instructions 574-719. Product Selection 4!JQPi9!L .. 4905 9938 SmartSync Control Module, Class A Dimensions: 4" x 4-1/8" x 1-1/4" D (102 mm x 105 mm x 32 mm); - or Class B output mounts in 4" (102 mm) square box 4905-9914 Class B Synchronized Flash Module Dimensions: 1-3/8" x 2-7/16" x 13/16" 0 (35 mm x 62 mm x 20 mm); epoxy encapsulated with 8" (203 mm) in/out 18 AWG (0.82 mm2) wire 4905-9922 Class A Synchronized Flash Module leads; rated for 2 A NAC; requires 5 mA for power Specifications General Specifications 4905-9938 SmartSync NAC Modules (for use with SmartSync compatible appliances) Input Voltage Range 16 VDC to 33 VDC; with a maximum ripple of 2 V peak-to-peak Output Ratings 2 A maximum; can be wired as Class A or Class B Up to 35 maximum SmartSync appliances with strobes Up to 40 maximum SmartSync horn-only appliances Strobe Control NAC Input Current en plus 30 mA @ 24 VDr SCM operating power Horn Control NAC Current 4mA@24VDC) Class A Operation Mounting Requirement Mount SCM within 20 ft (6 m) of control panel, use metal conduit 4905-9914 & 4905-9922 Synchronization Modules Input Voltage Range 1 16 VDC to 33 VDC 2 A maximum output; requires 5 mA for power Output Ratings Up to 35 maximum strobes per synchronized circuit Mount in control panel or separate 4" (51 mm) square electrical box, 1-1/2" (38 mm) minimum depth S4905-0003-2 9/2004 NAC Capability Reference Contro Panels/NAC Soie Available Output '" Module Required/Fuition Class A or Class B Strobe Synchronization 4010 Series Fire Alarm Control NA Panels Class B SmartSync Operation 4905-9938 for Class A SmartSync operation 4006, 4008, and 4100U Series Class A or Class B Strobe Synchronization NA Fire Alarm Control Panels Class A or Class B SmartSync operation NA Model Series 4003, 4004, 4005, Conventional reverse polarity NACs, 4905-9914 for Class B synchronized strobes 4100, 4120, 4020, 4001, & 4002 Control Panels; 2190 Series additional modules are required to control 4905-9922 for Class A synchronized strobes Signal ZAMs; 4009 Series synchronized strobes and/or SmartSync 4905-9938 for SmartSync control Conventional NAC Extenders appliances 4009 IDNet NAC Extenders Class A or B Strobe Synchronization NA Class B SmartSync Operation 4905-9938 for Class A SmartSync operation Module Reference Module 5ription SmartSync Control Module, provides Class A or Class B SmartSync operation 4905-9914 Class B Strobe Synchronization Module 4905-9922 Class A Strobe Synchronization Module Compatible Appliance Reference LAppance Type •T. ___ ___ Horn Wall mount; selectable for SmartSync operation Model 4901-9820 4905-9938 Strobes Wall mount; synchronized; also SmartSync compatible _______________________________ 4904-9331 4904-9342 4906-9101 4905-9914 4905-9922 4905-9938 4904-9332 4904-9343 4906-9103 4904-9333 4904-9344 Ceiling mount; selectable for synchronized flash; also SmartSync compatible 4904-9183 4904-9345 4906-9102 4904-9184 4904-9346 4906-9104 4904-9185 - AN Horn/Strobe Wall mount; horn and strobe can be wired separately (4-wire); strobes are selectable for synchronized flash 4903-9425 4903-9427 4903-9432 4905-9914 4905-9922 4903-9426 4903-9431 4903-9433 Wall mount; SmartSync operation only (2-wire) 4903-9331 4903-9342 4906-9127 4903-9332 4903-9343 4906-9129 4903-9333 4903-9344 Ceiling mount; SmartSync operation only (2-wire) Q6 9i8 4906-9130 Rectangular case wall mount; horn and strobe can be wired separately (4-wire); strobes are selectable for synchronized flash 4903-9252 4903-9257 4903-9256 4905-9914 4905-9922 4903-9253 4903-9258 4903-9254 4903-9255 SN Speaker/Strobe Wall mount; strobes are selectable for 4903-9356 4903-9359 4906-9151 4905-9914 4905-9922 synchronized flash 4903-9357 4903-9360 4906-9153 4903-9358 4903-9361 Ceiling mount; strobes are selectable for synchronized flash 4903-9196 4903-9198 4906-9154 4903-9197 Rectangular case wall mount; strobes are selectable for synchronized flash 4903-9148 4903-9150H 4903-9194 4903-9149 __________ 4903-9153 4903-9195 4903-9150 4903-9193 *Bolded PIDs are Multi-Candela products. ** Modules listed are required if control panel NAC or NAC extender does not provide either synchronized strobe output or SmartSync control output as required for proper appliance operation. S4905-0003-2 9/2004 SCM Installation Reference 116 Mounting Box (by others): Square box, 4" (102 mm), required depth depends on total conductor requirements Minimum depth = 2-1/8' (54 mm), RACO 232 or equal 4" square cover plate, RACO 752 or equal Extended depth (for maximum (by others) conductors), add 1-1/2" (38 mm) extension ring, RACO 201 or equal Tyco, Simplex, the Simplex logo, TrueAlert, and SmartSync are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. Tyco Safety Products Westminster• Westminster, MA 0144 1-0001• USA S4905-0003-2 9/2004 .Simplex www.tycosafetyproducts-usa-wm.com 0 2004 Tyco Safer,' Prochicts Westminster All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:235 Page 1 of I CATEGORY: Fire Alarm Device for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN-'Models "TrueAlert non-addressable "4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable " 4904-9168, 4904-9171, 4904-9169, 4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904- 9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904- 9360, 4909-9361 synchronized strobe lights. ModeloEiioync control module. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, *..9353 -9356, *..9359 -9168, -9171: 15cd, 1 Hz. 4904-9332, -9343, *..9351 *..9354 *..9357 *..9360 -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, *..9352 9355, *..935 -9361: 110cd, 1 Hz. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. *Corrected 03-04-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager BSimplex TrueAlert® Multi-Candela Notification Appliances UL, ULC Listed; Visible Notification Appliances with Horn and Synchronized FM Approved* Flash; Non-Addressable, SmartSyncTM Operation Compatible Iiuii*. Audible/visible (NV) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair Horn control that can be selected to be temporal coded, march time coded, or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938 Class A (Style Z) operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs Wall mount A/Vs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich output sound suitable for either coded or steady operation UL listed to Standard 464 FI:RE dplo Wall and Ceiling Mount A/Vs Dscrintic Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. I1IT1Ti1 rnnrri During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product was not approved by CSFM or MEA (NYC) as of document revision date. Refer to page 2 for listing status of wire guards. Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operabon is protected by U.S. patent No. 5,559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. S4906-0002-1 7/2004 RE MET, M0 17MR-111mr-M M-1 Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). PTEM Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." SmartSync Control Sources 4100U and 4010 Fire Alarm Control Panels (refer to data sheet S4010-0001 for details; refer to data sheet S4100-003 1 for basic 4100U information) 4009 lDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-993 8 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. 71rrrl-flriTrI1 Multi-Candela AIVs Description 4906-9127 I Wall Red White Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9129 White Red 4906-9128 .- —L I Ceiling Red White control White Red 4906-9l3 Op Wall Mount A/V Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to Cover 1-1/2" (38 mm) deep 4905-9940 White surface mounted boxes depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) SmartSync Control Module ';Dimension 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs L_Model Description - - -- Dimensions - 4905-9994 Red cover with white "FIRE" lettering 5-1/8" H x SW x 1-1/2" D 4905-9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount A/V Adapter ModeI Description - - - Dimensions 4905-9961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 49059927* Red Wire Guard for mounting to flush mounted electrical box (216 mm 156 mm x 76 mm) 49059928* Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4" x 6-7/8" x 1-1/2" deep, 4905-9916 Red 1-1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) "UL listed by Space Age Electronics Inc 2 S4906-0002-1 7/2004 Wall Mount or Ceilina Mount. Common Soecifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 VDC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Horn Output Ratings Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft (3 m) Reverberant Chamber, UL 464 Test 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8"H x 5"W x 2-3/4"D (130 mm x 127 mm x 70 mm) Wall Mou nt Maximum RMS Current Rating per Strobe Strobe Setting (see Note 3 below) 15 cd' 30 cd 75 cd.- 110 cd 75 mA 116 mA 221 mA 285 mA 18 VDC, at other voltages 24 VDC 70 mA 101 mA 184 mA 243 mA 60 mA 84 mA 143 mA 185 mA Housing Dimensions (with lens) 4-3/4 L" x 6-7/8" W x 2-5/8" D (121 mm x 175 mm x 67 mm) Ceiling Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd .30 cd 75 cd Jj.Q.. 86 mA (320 mMount A) 132 mA 250 mA Reference RMS Currents I8VDC at other voltages 24 VDC 81 mA 119 mA 216 mA 70 mA 97 mA 167 mA . 217 mA NOTES: Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) LTh çTh ( Mounting is compatible with single gang, double gang, and Hi, 4" (102 mm) square boxes, 1-112" (38 mm) deep, by others Wiring access hole 0 '' a Wiring terminals for a ff1 SmartSync operation EFEH Removable cover Strobe intensity - (tool required) viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even ith, orslightly w above bottom of compatible boxes T7=ne NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0002-1 7/2004 Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; 15 factory setting is 15 cd Ceiling Mount AN and Guard Installation Reference Ceiling reference, 4" (102 mm) square box, surface mounted box 1-1/2" (38 mm) minimum depth C 0 0--I ::: (D — Ceiling reference, -. flush mounted box Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are located behind the housing Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side - III1II1IIIL'iU L- MLiI Optional 4905-9927 Red Wire Guard End View ------------------------------------ Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing: factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt 45 Box Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mm) square box profile, 1-1/2" (38 mm) deep Optional 4905-9961 Wire Guard AN .0 4905-9931 Adapter Plate 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red: 4905-9940, White (conduit knockouts are provided on all four sides) Tyco, Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSync are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). 93 Tyco Safety Products Westminster" Westminster, MA • 01441-0001 • USA S4906-0002-1 7/2004 .Simplex www.tycosafetyproducts-usa-wm.com C2004 Tvco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:317 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4906-9127, 4906-9129 wall mount and Models 4906-9128 and 4906-9130 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detaile ct description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used listee's separately listed fire alarm control units. All models require the use of Mode 4905-9938 SFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are-u-s-e-d with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation Instruction Manual for details. 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation * criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager U SimplexGrinnell LP 9855 Carroll Canyon Road tqcaIFire &ff SanDiego,CA 92131 Security /SimplexGrinne Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com Policy Number: RMWC5898786 Effective Date: 10/01/2004 Expire Date: 10/01/2005 SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. 8/9/2005 REV.#: 0 PROJECT #: 480-402025-0 tqca /Fire & IS implex6rinneff Security SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com Contractor License # 802591 * * * Business Information * * * SIMPLEX GRINNELL L P 6952 PRESTON AVE STE A LIVERMORE, CA 94550 Business Phone Number: (925) 273-0100 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2005 * * * License Status * * * This license is current and active. All information below should be reviewed. * * * Classifications * * * Clas 11 Description IclTcL [C16 I FIRE PROTECTION * * * Certifications * * * Description F- ASBESTOS - (for bidding purposes * * * Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 81880913 in the amount of $10,000 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2004 Contractor's Bonding History BOND OF QUALIFYING IND1VIDUAL(1): This license filed Bond of Qualifying Individual number 81880915 for RONALD GILBERT MAYLE in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 BOND OF QUALIFYING INDIVIDUAL(2): This license filed Bond of Qualifying Individual number 81880914 for FRANKLIN MICHAEL BROWN in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 * * * Workers Compensation Information * * * This license has workers compensation insurance with the AMERICAN HOME ASSURANCE COMPANY 8/9/2005 REV.#: 0 PROJECT #: 480-402025-0 SimplexGrinnell LP 9855 Carroll Canyon Road tLgcQ I Fir Security e & /SimPIexGrinne San Diego, CA 92131 Tele: (858) 740-0100 I Fax: (858) 740-0156 www.simplexgrinnell.com APPENDIX ITEM DESCRIPTION A BUSINESS LICENSE B WARRANTY 8/31/2005 REV.#: 0 PROJECT #: 480-402025-0