The Concealer®
A Concealed Sprinkler
With Y2" (13mm) or
1%" (38mm) Adjustment
Features
Push-on/Thread-off cover plate assembly
attachment with ½" (13mm) adjustment.
Does not require clips or springs.
11/2" (38mm) Total adjustment provided by
adjustable inlet versions.
Adjustable inlet version available with either
1" NPT ale or female threads eliminating
costly reducing coupling.
Smooth aesthetic ceiling profile.
Available in white or other color painted or
brass, chrome, or black plated finishes.
Ordinary and intermediate temperature
ratings.
Multiple orifices for design flexibility.
Approvals & Listings
Underwriters Laboratories Inc. (UL)
Underwriters Laboratories of Canada. (ULC)
N.Y.C. BS&A No. 587-75-SA.
Note: Approvals are for light and ordinary hazard, except for
small orifice sprinklers which are limited to light hazard
occupancies. The cup and skirt are fabricated from plated
steel and are intended for interior non corrosive applications.
U.S. Patent No. 4,880,063.
Application
The Reliable Model G4
Concealer® is the most versatile
concealed sprinkler available. It
provides the best form of fire pro-
tection while offering an attractive
appearance and ½" (13mm) of
cover adjustment for ease of instal-
lation. The adjustable 1" NPT inlet
versions have iy" (38mm) of total
adjustment and also eliminates the need for a reducing cou-
pling. The small diameter Push-on/Thread-off cover plate
assembly is easily attached and blends into the ceiling, con-
cealing the most dependable fire protection available, an
automatic sprinkler system.
'Aso---002_16
Bulletin 121 Red
Model G4 Concealed
Automatic Sprinkler
-S
CD
Ilk
The Concealer® is designed for use where aesthetic ap-
pearance is important. Offices, hospitals, motels and res-
taurants are but a few of the applications where it can be
used. It is available in different orifice sizes allowing the de-
signer to optimize system performance, thereby achieving a
most efficient installation.
The Concealer® can eliminate the need for precise cutting
of drop nipples. The Push-on/Thread-off cover plate assem-
bly can be adjusted without tools so it mates accurately with
the ceiling. The fire protection system need not be shut
down to adjust or remove the cover plate assembly.
Product Description
The Reliable Model G4 Concealer® uses the proven
Model C fusible element in a standard style sprinkler frame
with a drop-down deflector. This assembly is recessed into
the ceiling and concealed by a flat cover plate. The
Push-on/Thread-off cover plate and sprinkler cup assem-
blies are held tight by a flexible tooth engagement to the
threaded cup. This threaded engagement provides ½"
(13mm) of cover adjustment. The flat cover plate is attached
to the skirt using an ordinary temperature classification sol-
der. This results in a strong cover plate assembly with an or-
dinary temperature rating, and an intermediate temperature
sprinkler which can be installed in 150°F (66°C) environ-
ments. When the ceiling temperature rises, the solder hold-
ing the cover plate to the skirt melts, the flat cover plate
released thus exposing the sprinkler inside to the rising am-
bient temperature.
The subsequent fusing of the sprinkler element opens the
waterway and causes the deflector to drop into position to
distribute the discharging water. Any secure engagement of
the threads between the cover plate and cup will assure that
the drop—down deflector is properly located below the ceil-
ing when a sprinkler operates.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552
Installation
Do not install The Concealer® in ceilings which have positive
pressure in the space in the space above.
After a 2/5 inch diameter hole is cut in the ceiling, the sprinkler
is to be installed with the Model G4 Wrench. The wrench has
drive tangs which insert into cup slots. When installing a sprin-
kler the wrench is first positioned into the sprinkler/cup assembly
until the wrench tangs engage drive slots in the top of the cup
(there are two sets of mating drive slots in the cup). The sprinkler
is then tightened into the pipe fitting. When inserting or removing
the wrench from the sprinkler/cup assembly care should be
taken to prevent damage to the sprinkler. DO NOT WRENCH
ON ANY OTHER PART OFTHE SPRINKLER/CUPASSEMBLY.
The adjustable inlet versions are similar to the standard Model
G4 except that an addition 1" (25mm) of adjustment is provided
by means of a telescoping inlet section that threads in or out of a
stationary coupling reducer (either 1 male or 1 female) as shown
in Fig. 2 or Fig. 3. These sprinklers must be installed before the
ceiling is in place, by wrenching on only the coupling reducer
Temperature Ratings
Classification Sprinkler Cover Plate Max. Ambient
Temp.
Ordinary 135°F/57°C 135°F/57°c 100°F/38°C
Ordinary 165°F/74°C 135°F/57°C 100°F/38°C
Ordinary 165°F/74°C 1651F/741C 100°F/38°C
Intermediate 212°F/100°C 165°F/74°C I 150°F/66°C
Installation Data
hex flats. After the ceiling has been installed with holes for the
sprinkler, each telescoping inlet section is to be adjusted with the
G4 Wrench. Install the push-on/thread-off cover plate assembly
over the sprinkler by holding and pressing it straight up into the
cup. Anal adjustment of each cover assembly is made by hand
turning it clockwise until it is tight against the ceiling.
Maintenance
The Model G4 Concealer® should be inspected quarterly and
the sprinkler system maintained in accordance with NFPA 25.
Do not clean sprinklers with soap and water, ammonia or any
other cleaning fluids. Remove any sprinkler that has been
painted (other than factory applied) or damaged in any way. A
stock of spare sprinklers should be maintained to allow quick re-
placement of damaged or operated sprinklers. Prior to installa-
tion, sprinklers should be maintained in the original cartons and
packaging to minimize the potential for damage to sprinklers that
would cause improper operation or non-operation.
Ordering Information Cover Plate Finishes (1)
Sprinkler Model
Temperature Rating
Nominal Orifice
Flat Cover Plate Finish
Inlet Type
Note: Unless otherwise
specified, the 165°F (74°C)
sprinkler will be provided with
the 165°F (74°C) cover.
Sta ndard Finishes
Bronze
Chrome Plated
white
Special Application
Finishes
Black Plated
Bright Brass
Off white
Black Paint
Nominal Sprinkler
Identification Sprinkler Total Nominal .tOt_ Thread Approvals Number Inlet Adjustment Orifice
(SIN)
Non-Adjustable ,t'(13mm) )ç'(15m) 5.6 80 )" NPT (R½) 1,2,3 R2115
Non-Adjustable ,t11(13mm) 7/6"01rrm) 4.2 80 )" NPT (R½) 1,2,3 R2113
Non-Adjustable X % "(l3mm) "(lOTrn) 2.8 40 )" NPT (R½) 1,2,3 R2111
Adjustable1X"(38mm) ,"(15ITfl1) 5.6 80 1"NFT Male orFernab 1,2,3 R2118
Adjustable 1,"(38mm) il(e"(11MM) 4.2 60 1"NPT Male orFemale 1,2,3 R2113
Adjustable 1X"(38mm) %"(lOfllTi) 2.8 40 1"NFT Made orFemale 1,2,3 R2112
Other colors and finishes are
available. Consult factory for
details
Note: Paint or any other
coatings applied over the
factory finish will void all
approvals and warranties.
Installation Wrench
Model G4 Sprinkler Wrench
ii
---1f,t-:-- 2 JLL__ lii
r 1.j--11- 1
ER I ti
ce(vJoed®
Fig. 1 - ,i/2" (R)) NPT Non— Adjustable Inlet Fig. 2 - 1" NPT Male—Adjustable Inlet Fig. 3- 1" NPT Female-Adjustable Inlet
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced bythe most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
- - The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Office
(800) 848-6051 Sales Fax
(914) 668-3470 Corporate Offices Revision lines indicate updated or new data.
www.reliabiesprinkler.com Internet Address EG. Printed in U.S.A. 06i02 P/N 9999970014