Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2525 EL CAMINO REAL; ; FA060007; Permit
11/21/24, 2:15 PM FA060007 Permit Data City of Carlsbad Fire Alarm Permit 2525 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 1563020900 Lot #: 0 Reference No.: Permit No: FA060007 Status: ISSUED Applied 3/21/2006 Approved: 4/4/2006 Issued: 4/4/2006 PC #: Inspector: Project Title: PAC SUN STE. 230 FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: SIMPLEX GRINNELL 9855 CARROLL CANYON RD SAN DIEGO CA 858-740-0100 Owner: PLAZA CAM INO REAL C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) L 11510 L 1150 about:blank 1/1 FAo 000- tqca /Fire & IS implexerinneff Security SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnelf.com FIRE DETECTION AND ALARM SYSTEM PRODUCT SUBMITTAL PROJECT: Pac Sun Plaza Camino Real 2525 El Camino Real Carlsbad, CA 92008 3/30/2006 REV.#: 1 PROJECT #: tqca /Fire & IS implex6rinneff Security SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tale: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM ITEM QTY MODEL NO. DESCRIPTION C.S.F.M. NO. A 1 4006-9101 Fire Alarm Control Panel 7165-0026:318 2 2081-9272 6.2AH Battery N/A B 6 4098-9788 2 Wire Base with LED 7300-0026:222 6 4098-9601 Photoelectric Smoke Detector 7272-0026:219 C 2 4098-9686 4-Wire Duct Detector 3240-0026:241 3/30/2006 REV.#: 1 PROJECT #: 5Simplex UL, ULC Listed; FM, CSFM, and MEA (NYC) Approved* Iiuit*i Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient panel status information Operation is programmable using a multi-function keypad and the panel LCD or via service computer (PC) RS-232 service port provides upload/download PC access for panel configuration and event history logs Software updates are via PC download Convenient library of standard custom label terms Standard on-board DACT provides: Contact ID, 3/1, 4/2, BFSK, and SIA formats WALKTESPM silent or audible system test** Voltage and current for both the battery charger and the battery can be displayed at the front panel LCD Five Standard Initiating Device Circuits (IDCs): Five Class B IDCs with optional expansion to ten, all with individual zone disable Monitor 2-wire or 4-wire initiating devices including TrueAlarm® smoke detectors Optional Class A Adapter Module Two Standard Notification Appliance Circuits (NACs): Class A or Class B outputs with solid state overcurrent protection per NAC, each rated for 2 A Selectable for Simplex® SmartSyncTM two-wire horn/strobe control or synchronized strobe controlt Standard Power Supply Provides 3 A maximum @ nominal 24 DC Automatic input power selection operates with 120 VAC or 240 VAC, 50 or 60 Hz On-board temperature compensated battery charger for up to 12.7 Ah batteries in cabinet (UL and ULC) and up to 25 Ah batteries in separate cabinet (UL only) Additional standard features: Two auxiliary relays IDCs, NACs, and Relay outputs are power limited per NFPA 72® (AC input, battery circuits, and City Circuit Module outputs are non-power limited) UL listed to Standard UL 864, 9th Edition Available option modules: Door mounted 24 LED annunciator (standard on ULC models) 3 A Expansion Power Supply with two on-board 2 A NACs that operate the same as standard NACs LifeAlarm`r&Fire Alarm Control Panels 4006 Series Fire Alarm Control Panels Providing up to Ten lDCs and Four NACs 4C06-9101 Standard Control Panel 4006-9121 Control Panel with 24 LED Annunciator Available option modules (Continued): Expansion IDC module with five Class B IDCs Class A [DC Adapter Module, City Interface Module, and Auxiliary Relay Module Remote LCD and LED/Switch Annunciators Dscrintin For areas recuEr ng from five to ten initiating zones, the Simplex 4006 Series fire alarm control panels provide flexible initiating circuit monitoring, extensive programmable control capability, and LCD annunciated circuit-specific 20 character custom label. * See page 2 for additional ULC and MEA information. This product has been approved by the California S~ate Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:318 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and pcssIe cancellation. Additional listings may be applicable, contact your local Simples® prodct supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are me property of Tyco Safety Products Westminster. ** WALKTEST sys:e-n testis protected under US Patent No. 4725,818. t SmartSync honjsrobe operation is protected under U.S. Patent No. 6,281,789. Two-wire synctiror ization circuit operation is protected by U.S. patent No. 5,559,492. S4006-0001-3 7/2005 Five Class B IDCs are each capable of supporting up to 30 Simplex current-limited smoke detectors or electronic heat detectors (see list on page 4) as well as manual stations and other compatible contact closure initiating devices. IDCs are capable of Class A operation with an optional adapter module and can be programmed as Style C (short or open initiates a trouble) for use with current limited devices only. Two, 2 A On-Board NACs provide conventional reverse polarity operation, selectable as Class A or Class B, with electronic control and overcurrent protection. Operation is selectable for synchronized strobe or SmartSyncTM horn/strobe two-wire operation. Horn control can be selected at the panel for: Temporal pattern coding, Steady On, Slow March Time (20 beats per minute), or Fast March Time (120 beats per minute). Note: When selected for SmartSync horn/strobe control, March Time produces 60 beats per minute. The 24 VDC Auxiliary output provides up to 500 mA for system use. (Auxiliary output current is counted for total power supply capacity.) Standard Auxiliary Relay Outputs. Two relay outputs are available, selectable as normally open or normally closed, rated 2 A @ 30 VDC per below: Aux Relay 1 is normally assigned to General Alarm operation but is programmable (see page 7) Aux Relay 2 (Trouble) is energized when Normal and is de-energized with a Trouble condition. On-Board Dual Line DACT. Operation can be selected for Contact ID, SIA, 3/1, 4/2, and BFSK formats. Reporting includes Alarm, Supervisory, Trouble, and AC Failure. Operation includes automatic 24 hour test and programmable power fail report delay. Power Supply and Battery Charger. DC power output is 3 A @ 24 VDC for panel use. The temperature compensated battery charger (sealed lead-acid batteries only) is rated for up to 25 Ah batteries per UL 864 and up to 12.7 Ah per ULC-S527. (Up to 12.7 Ah batteries fit in the cabinet, larger batteries require an external cabinet.) Panel electronics can measure and display voltage and current for the power supply, batteries and the battery charger (standard and expansion power supply). Depleted battery trouble is monitored and annunciated and depleted battery cutout can be selected. Active battery status monitor supervises charger operation. IMP W-IMEMERIT-lem- M. Expansion Power Supply. Provides 3 A total 24 VDC, two additional 2 A NACs, and an additional auxiliary power output of 500 mA. Output operation is the same as on the standard power supply. Expansion IDC Module. Provides 5 additional Class B IDCs with operation the same as the standard IDCs. Expansion Relay Module. Provides 10 programmable relays, jumper selectable as N.O. or N.C. Contacts are rated 2 A @ 30 VDC. Typical application is to track status of each IDC. See page 7 for relay program options. Class A Adapter Module. Converts 5 IDCs from Class B to Class A operation. Two modules can be mounted for use with the Expansion IDC Module. City Circuit Modules. These modules are available with or without on-board disconnect switches, depending on local requirements (either type can be disconnected through the front panel under password control). Connections are for Remote Station (reverse polarity) or Municipal Master (local energy). Reporting includes Alarm, Supervisory, and Trouble. Control Panel 0 e scription LiStii 4006-9101 andard fire alarm control panel UL, FM, 4006-9121 ire alarm control panel with & CSFM 24 LED Annunciator on front door MEA 4-1/4" Red cabinet; 5 Class B IDCs, 2 Class B/Class A (108 mm) NACs, 3 A power supply with battery charger; on-board DACT; for input voltage of 4-5/8" ULC (117 mm) 120/240 VAC, 50/60 Hz (autoselect) ifThePth Standard Features j Option Modules Model Description = - 4006-9801 Expansion Power Supply; 3 A, with 2 NACs, 120/240 VAC, 50/-60--Hz- 4006-9802 Expansion IDC Module; 5 Class B IDCs Select up to one of each as required 4006-9803 Expansion Relay Module; 10 relays selectable as either N.C. or N. C. 4006-9804 Class A Adapter Module; converts 5 IDCs from Class B to Class A Select up to two maximum 4006-9805 City Circuit Module with disconnect switch 4006-9806 City Circuit Module without disconnect switch Select one if required Accessories Model Description 2975-9812 Red semi-flush trim kit; 1-7/16" (37 mm) wide; includes four corners and trim pieces for top, bottom, and sides 4009-9801 Beige External Battery Cabinet for up to 25 Ah batteries; mounts close-nippled to control panel cabinet; dimensions = 16-1/4" W x 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) [depth increased for 25 Ah effective 7/20051 Batteries, 12 Volt (select one battery model per system standby requirements; order quantity of two) M61) Size I Model I Size I Location - Model I Size Location 2081-9272 I) 6.2 Ah 2081-9288 12.7 Ah 11 10 Ah For cabinet mount S4006-0001-3 7/2005 2081-9275 18 Ah 1 Requires 4009-9801 External Battery 2081-9827 25 Ah 1 Cabinet (UL listed only) Keyboard Reference FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on until reset 2 X 20 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 20 characters for custom label information FIRST ALARM DISPLAY: Operation can be selected for maintained display of first alarm until acknowledoed THREE PROGRAMMABLE LEDs provide custom labeling (labels insert into a pocket), the top two LEDs are selectable as red or yellow, the bottom LED is selectable as green or yellow SYSTEM NORMAL 12: 35: 15 m 6/03/05 CONTROL PANEL I PANEL VIEW with door closed - ALARM ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the active Alarm list SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal TROUBLE ACK acknowledges I Ito be silenced, used after evacuation is complete and system troubles, logs the \ (while alarm source is being investigated acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the FOUR EXTENDED FUNCTION KEYS: ENTER confirms active Trouble list selections, EXIT/CLEAR backs out of the present screen menu and clears information that has not been entered, FUNCTION enables the active function menu, DISABLE/ENABLE toggles the function or circuit status as appropriate per the selected screen SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the active Supervisory list I I ALARM SILENCE causes audible notification appliances hi! ts th FIVE NAVIGATION KEYS: MENU selec e on-screen programming menu; left and right arrows moves the position on the screen, and PREVIOUS and NEXT navigate screen selections RED LED IDC1 IDC5 - IDC9 IDC2 IDC6 IDC1O IDC3 IDC7 T1 ID 14 CUSTOM LABEL AREAS are available, typically for IDC and NAC annunciation (shown labeled for reference, blank I FOUR YELLOW LEDs provide labels are provided); dual LED locations have a Red LED default NAC Trouble annunciation (top) and a Yellow LED (bottom); labels insert into pockets ((shown labeled as NAC 1-4) behind the overlay; LED operation is programmable to track other monitored status conditions S4006-0001-3 7/2005 Sioecifications (Refer to I -f M4"fi-1 "I If- owerRatings Input Voltage J 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select AC Input Ratings Input Current, Standard 12 A maximum @ 120 VAC input; 1.5 A maximum @ 240 VAC input Input Current with Expansion Power Supply 4 A maximum @ 120 VAC input; 3 A maximum © 240 VAC input Power Supply Output Rating 3 A maximum © 24 VDC in alarm (see NAC details on page 6) Temperature compensated charger is rated for up to 25 Ah per UL 864; up to Battery Charger 12.7 Ah per ULC-S527 Standby Current 130 mA; with 5 lDCs fully loaded, tone-alert silenced, trouble LED on Standard Circuit Ratinqs (NOTE: Total DC current= 3A maximum) - - Notification Appliance Circuits (NACs) NOTE: See details on page 6 2A maximum @24VDC, per circuit; available as Class Aor Class B; - - Class B end-of-line resistor = 10 1/2W; Model 4081-9008 (P/N 733-894) Supervisory Current Initiating Device Alarm Current 3 mA maximum 60 mA maximum Circuits (IDCs) Capacity Each IDC supports up to 30 detectors (smoke or electronic heat) and manual stations as required; wiring distance is limited to 50 C) maximum End-of-Line Resistor 3.3 kC), 1/2 W; Model 4081-9002 (P/N 733-893) for Class B lDCs Quantity Supported Up to four annunciator modules per panel (see page 5 for details) Wiring Type Twisted pair, or twisted, shielded pair; 18 AWG (0.82 mm2) Bus-Style Wiring Up to 4000 ft (1219 m); 0.58 i.iF (580 nF) maximum capacitance; 35 C) max. Annunciator °T-Tap" Wiring Up to 10,000 ft (3048 m) total wiring; up to 2500 ft (762 m) to farthest device Communications Line Matching Resistor Bus-style, connect one at panel 100 C), 1/2 W; 4081-9011; T-Tap, connect one at panel and one at end of line (part number 733-974) Suppression Use 2081-9044 Overvoltage Protectors where wiring leaves and enters a building (refer to data sheet S2081-0016) Auxiliary Power Output 500 mA maximum © 24 VDC Standard Auxiliary Relay Outputs Relay 1 Relay 2 Programmable operation I Contacts rated 2 A @ 30 VDC, 0.35 power factor; jumper selectable as N.O. or N.C. Trouble operation Wiring Connections for Above Circuits and AC Input Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) 9p gs = Class A lDC Adapter Module Five circuits per module, rated same as circuits Ten Relay Auxiliary Contact Ratings 2 A @ 30 VDC, 0.35 power factor; jumper selectable as N.O. or N.C. Module 4006-9803 Wiring Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) Environmental Ratings Operating femperature Range 32° to 120°F (0° to 49° C) Operating Humidity Range Up to 93% RH, non-condensing @ 100.4° F (38° C) maximum Reference Information, Compatible Simplex Peripherals Compatible Simplex Detectors Model 4098-9601 jyr~! Photoelectric smoke detectors for 2-wire and 4-wire bases Description - Standard detector (2.8% nominal) DataSheet S4098-0015 4098-9605 Reduced sensitivity detector (3.5% nominal) 4098-9602 Combination smoke and heat detector S4098-0017 4098 Series Duct detector housings 2-wire and 4-wire models 84098-0029 4098 Series Ionization Smoke Detectors 2-wire and 4-wire models S4098-0018 4098-9612 Electronic heat detectors for 2-wire and 4-wire bases 135° F (57°C) I Fixed temperature heat detector I S4098-0014 4098-9614 200° F (93°C) 4098-9613 135° F (57°C) I Fixed temperature heat detector with rate-of-rise detection 4098-9615 200° F (93°C) Compatible System Expansion Panels Model Type Description - Data Sheet Provides a remote voice control panel with on-board NACs, internal 4003 Series Voice Control Panel S4003-0001 microphone, and remote microphone input 4009 Series Remote NAC Extender Provides remote NACs; includes power supply and battery charger; S4009-0002 4 extenders max/NAC; 4006 uses NAC output to provide control Note: Contact your local Simplex Product Supplier for additional compatible peripherals 4 S4006-0001-3 7/2005 'Rfodel J.sipor Alarm 4006-9101 Standard fire alarm control panel 130 mA - 160 mA + 60 mA per IDC in Alarm - 4006-9121 Control panel with 24 LED Annunciator (._)s48.iAX.___+6 21 rn rn per in larm 4006-9801 Expansion Power Supply 50 mA 60 mA 4006-9802 Expansion IDC Module 50 mA 50 mA + 60 mA per IDC in Alarm 4006-9803 Expansion Relay Module 0 mA 0 MA + 10 mA per energized relay + 10 mA per energized relay 4006-9804 Five Circuit IDC Class A Adapter 0 mA normal; 0 mA normal; 10 mA per IDC in trouble 10 mA per IDC in trouble 4006-9805 City Circuit Module with disconnect switch 30 mA 60 mA 4006-9806 City Circuit Module without disconnect switch 30 mA 60 mA 4606-9101 Remote LCD Annunciator (see data sheet 100 mA 150 mA S4606-0001) 4610-9111 Remote LED/Switch Annunciator (see data 40 mA 70 mA sheet S4610-0001) (all LEDs and tone-alert on) ** Current Calculation Information: To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. Remote Annunciator Options I - The 4006 supports up to four annunciator options including: Door Mounted 24 LED Annunciator 4610-9111 Remote LED/Switch Annunciators 4606-9101 Remote LCD Annunciators Annunciators communicate at a rate of 9600 baud with 24 VDC power supplied by separate wiring. 4610-9111 LED Annunciator Features: 4606-9101 LCD Annunciator Features: LCD readout with two lines of 40 characters each and LED backlighting Wide viewing angle, super-twist design Keyswitch access controlled Control switches and status LEDs for: Alarm, supervisory, or trouble acknowledge Alarm silence and System Reset 16 LEDs with programmable functions and dedicated Three programmable LED indicators: LEDs for Alarm Silenced, Lost Communications, Trouble, and Power-on • Two LEDs are selectable as red or yellow Keyswitch access controlled switches for • One LED is selectable as green or yellow Acknowledge, Alarm Silence, Reset, and Lamp Test • With provisions for custom labeling Local tone-alert SYSTEM IS NURt4AL samj2j 04 4610-9111 LED/Switch Annunciator 4606-9101 LCD Annunciator 5 S4006-0001-3 7/2005 IDC Operation Modes The following IDC operation modes are selectable from either the front panel or the PC programmer I .11 T TT !!T 11 Normal = NORMAL FIRE Fire monitor zone Current Limited = FIRE Short = FIRE Open = TROUBLE WATER Waterfiow monitor zone Normal = Current Limited = Short = Open = NORMAL FIRE FIRE TROUBLE HEAT Heat detector zone DUCT Duct detector zone PULL Manual (pull) station zone SMOKE Smoke detector zone Normal = NORMAL SO Sprinkler Supervisory Current Limited = SUPERVISORY Short = SUPERVISORY Open = TROUBLE Normal = NORMAL WSO Combination waterfiow and water supervisory Current Limited = SUPERVISORY zone Short = ALARM Open = TROUBLE Normal = NORMAL SUPV Supervisory monitor Current Limited = SUPERVISORY Short = SUPERVISORY Open = TROUBLE Normal = OFF UTIL Supervised utility monitor Current Limited = ON Shortr ON Open = TROUBLE Normal = NORMAL TROUBLE Trouble monitor Current Limited = TROUBLE Short = TROUBLE - Open = TROUBLE Normal = NORMAL Verified fire alarm; the abnormal (current limited) Current Limited = VERIFY VSMOKE state causes the alarm verification cycle to start; a short is an immediate alarm Short = FIRE Open = TROUBLE Normal = NORMAL STYLEC Style C fire monitor Current Limited = FIRE Short TROUBLE Open = TROUBLE Normal = NORMAL LATSUPV Latching supervisory monitor (supervisory Current Limited = SUPERVISORY latches until system is reset) Short = SUPERVISORY Open = TROUBLE Detailed NAG Ratings NAG Ratings, Maximum per NAC Appliances - - - - Simplex 4901 Series (horns) and the following 4906 Series Multi-Candela: strobes, Special Application: horn/strobes, and speaker/strobes (see data sheets S4906-0001, S4906-0002, & strobe synchronization is UL listed across all S4906-0003) 4 system NACs for these 4906 Series 4906-9101 4906-9103 4906-9127 4906-9129 4906-9151 4906-9154 appliances 4906-9102 4906-9104 4906-9128 4906-9130 4906-9153 Regulated 24 VDC: j. NOTE: Maximum strobe load on main power supply or expansion power supply is 1.35 A All other UL Listed Notification Appliances; use associated external per power supply (2.7 A total); remainder of synchronization modules where required power supply rating is available for other S4006-0001-3 7/2005 Relay Operation Modes The following relay operations are selectable from either the front panel or the PC programmer. Common Fire Alarm Operations Fuy ayActwaft 'Upon Relay Deactivates Upon SRELAY General Alarm Silence RRELAY General Alarm Reset SUPV Supervisory condition Clear TRBL Trouble condition Acknowledged Special Functions Function Type UTILITY Description Utility IDC in the same alarm group activates PRIMARY General alarm; relay is tied to Primary Elevator Recall contacts ALTERN General alarm; relay is tied to Alternate Elevator Recall contacts DRESET Relay provides 24 VDC power to 4-wire detectors; relay turns off for 5 seconds on System Reset DHOLDER Relay provides 24 VDC to larger door holder relay with separate power source; relay activates on general alarm to remove power to door holder relay and close doors Additional Programming Feature Details Function Details Custom labels Up to 20 characters per point; a built-in message library provides for commonly used words for easy front panel programming For front panel label creation convenience, the following words can be selected as part of a custom label (_designates a built-in space; typing the first letter of a word/number will select the closest word in alphabetical/numerical_sequence) Message Library North Center Fir Basement Floor Lobby Lobby main Boiler_RM Elevator South rear Flr_4 Garage Office first Classroom Entrance Storeroom East 5th Flr_5 Hallway Patient 2nd Closet_ Restroom Wing West Fir-1 RM_ HVAC_Room upper 3rd Corridor Room Zone Front Flr_2 Kitchen lower 4th Elect RM Stairway Three separate logs: Alarm (100 entries), Supervisory (100 entries), and Trouble (300 entries); logs can be History logs queried separately, or as a combined log; logs can be downloaded for printing or archiving using the RS-232 service port Automatically scans system for installed option modules and configures panel programming accordingly; Autoprogram modes are available to detect new modules only, recreate default programming and then add all modules found Alarm Groups Up to 99 alarm groups are available, any point may be in up to 3 alarm groups; this allows NAC and relay operation to be associated with IDC inputs according to local response requirements WALKTEST Allows one person to perform system testing; alarm or trouble tests are followed by automatic reset; the alarm zone is sounded out by associated audible notification or the response is silently logged into the Alarm log Manual Control Allows selection of individual relays or NACs for system testing Level 1 = Acknowledge, Silence, System Reset, View logs, View point information, and Lamp Test Passcode Protection Level 2 = All Level 1 + Set Time/Date, Point Control, Enable/Disable points (4-digit number) Level 3 = All Level 2 + Clear logs, Clear verification tallies, Custom label editing, and WALKTEST Level 4 = All Level 3 + Programming, Upload/Download; this is the Service access level S4006-0001-3 7/2005 Installation and Module Placement Reference Box width 15-5/8" (397 mm) ij M are top s l Q c: cO 0 (Top and side views are shown with door installed) Box depth = 4-1/4" (108 mm) standard 4-5/8" (117 mm) w/annunciator door (IDC I 11-1/4" (286 mm) _—"I Module* Expansion) Class A Adapter .0 I fm liiiiiiii 111111111 11-11111111 1! IIIIIIIIFli o. 0 0 ERel:a, M. j.__. I!J111111111111111111ir11111IFtI III IIIfl - on M F r,r-ir--ir-ir-I 4 Door thickness I I 5/8"(l6mm) W OE I%I (406 mm) CMain board)W U0 __________ CAC Input Terminals (City Module* Power Supply* I (extends under DC Expansion 1Module space) — I Battery Area 1 No conduit or wiring in this area - II 13-1/4" (337 mm) NOTE: For semi-flush mounting, cabinet * Indicates optional modules must extend 1-1/2" (38 mm) minimum from wall surface Tvco, Simplex, the Simplex logo, TrueAlarm, WALKTEST, and SmartSvnc are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4006-0001-3 7/2005 .Simplex www.tycosafetyproducts-usa-wm.com © 2005 Tvco Safety Products Westminster. All rights reserved. Al/ specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:318 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Model 4006-9101 006-9121,4008-9101, and 4008-9121 Commercial Fire Alarm Control Panels. Loca, auxiliary, remote station, central station service. Refer to listees data sheet for additional detailed product description and operational considerations. System components: 4006-9801, 4008-9801 4006-9805, -9806 4006-9804 4006-9803, 4008-9802 4006-9802 4090-9007 Expansion Power Supply (EPS) City Circuit Modules (CCM) Class A Adaptor (CLA) Relay Modules (ARM) Expansion Initiating Device Circuit (XIUM) IDNet Signal Individual Adapter Module (SigI) RATING INSTALLATION MARKING APPROVAL: 120 v, 60 Hz, 2 A In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. 12-14-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager BSimplex Fire Alarm Control Panel Accessories Cabinet Mounted System Batteries; 2081 Series, Sealed Lead-Acid; 6.2 Ah to 50 Ah Rechargeable, sealed lead-acid design: Lead-calcium grid structure Immobilized electrolyte in absorbent separator High reliability dual seal construction Low maintenance, no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size For applications requiring 110 Ah batteries: Refer to data sheet S4081-0002 for 4100U systems Refer to data sheet S2081-0012 for 4100/4120 series system iescrintir Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets I 'Tl(iThI.J1lJaj Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Specification Summary Nominal Voltage Rating 12 V/battery Discharge Rating 20 Hour Rate Typical Chart/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 600 F to 900 F (15.6°C to 32.2° C) These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. S2081-0006-16 9/2004 Inner cover Absorbent sei used to imrr ele Lead-calciur C Typical Construction Details Actual appearance will vary with battery size. Cell case (high impact polystyrene) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator S2081-0006-16 9/2004 Battery Specifications Capacity20 HOUr Width" WeL ighr, Height with Approximate x,- r-7 2 2 081-9272 Dcharge Rate Terminals 2-5/8" (67 mm) 6.2 Ah 6-1/8" (156 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 10 Ah (153 mm) 4-1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6(153mm) (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) (127 mm) (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 (square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) I 2081-9296 1 50 Ah 9-1/2" (241 mm) 1 5-1/2" (140 mm) 1 8-7/8" (225 mm) 1 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Model Capacity Simplex Control Panel Model Series (see legend and notes below) 4003 4004 4004R 4005 4006 & 4008 4009 (all models) 4010 4100U (2 or 3 bay) 4100 &4120 (2, 4 or 6-Unit) 4020 (2, 4 or 6-Unit) 20819272 6.2 Ah f 1 1 1 f 1 1 1 1 1 2081-9274 10 Ah 1 1 1 1 1 1 1 1 1 1 2081-9288 12.7 Ah 1 1 1 1 1 1 1 1 1 2081-9275 18 Ah / Note 3 1 Ext Ext Note 2 1 1 1 2081-9287 25 Ah Note 3 Ext 1 1 1 Ext 2081-9271 (rectangular) 33 Ah Note 3 Ext Note 3 1 Ext Note 4 2081-9276 " 33 Ah (square) Note 3 Ext Note 3 If 1 Ext 2081-9296 50 Ah Note 3 Note 3 / Ext Ext / = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 Shaded areas = Not applicable NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. S2081-0006-16 9/2004 External Battery Cabinet Compatibility Reference Externally Mounted Battery Battery Cabinets without Chargers Battery Capacity Cabinets with Chargers (connects to charger in panel) 4081 Model 2081-9301-1 2081-9303— Series 2081-9270** 2081-9281 2081-9282 4009-9801 4009-9802 2081-9275 18 Ah 2081-9287 25 Ah 2081-9271 / (rectangular) 33 Ah 81-9276 0su 2081-9296 50 Ah * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. /= Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specification Reference odel Descnption - Color Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 20819270* External battery cabinet without charger Red 26-1/2W x 12" H x 12" D 20819301* External battery cabinet with charger * 2081-9302 External battery cabinet without charger and with meters for voltage and current (673 mm x 305 mm x 305 mm) 2081-9303 External battery cabinet with charger and with meters for voltage and current 4009-9801 For up to 18 Ah External battery cabinet without charger, 16-1/4" W x 13-1/2" H x 4-1/8" D batteries with solid door and battery harness, for close-nippled mounting to fire alarm control Beige (413 mm x 343 mm x 105 mm) For up to 33 Ah 25-3/4" W x 20-3/4" H x 4-1/8" D 4009-9802 batteries panel cabinet (654 mm x 527 mm x 105 mm) 4081 For up to 50 Ah Companion cabinet with charger for the Beige or 22-1/2" W x16-3/4" H x 8-3/8" D Series** batteries 4010 and 4004R fire alarm control panel Red (572 mm x 425 mm x 213 mm) * Refer to Simplex data sheet S2081-0002 for additional information. ** Refer to Simplex data sheet S4081-0001 for additional information. Tyco, Simplex, and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. 93 co Safety Products Westrninster• Westminster, MA • 01441-0001 • USA S20981-0006-16 9/2004 a -mplex Ty www.tycosafetyproducts-usa-wm.com 0 2004 Tt'co Safety Products Westminster. All rights reserved All specifications and other information shown were cnn-ent as ofdocument revision date and are subject to change without notice. BSimplex TrueAlarm® Smoke Detectors UL, ULC Listed; FM, CSFM, TrueAlarm Photoelectric Smoke Detectors and MEA (NYC) Approved* for Two-Wire and Four-Wire Bases Photoelectric smoke detector with on-board TrueAlarm sensitivity drift compensationt UL listed to Standard 268 Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: 4098-9601, Standard Sensitivity, nominal 2.8%/ft obscuration 4098-9605, Special Application Sensitivity, nominal 3.5%/ft obscuration Available base options: Bases for 2-wire or 4-wire operation Auxiliary alarm relay output Optional remote alarm indicating LED I'i*iFUT1 Simplex® TrueAlarm photoelectric detectors provide many of the proven TrueAlarm analog sensing features for applications where detectors are connected to conventional 2-wire or 4-wire initiating device circuits (IDCs). Each TrueAlaim detector has an on-board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. TrueAlarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high performance smoke capture abilityt Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. 4098-9601 TrueAlarm Photoelectric Detector Mounted in Base Specifications Voltage Standby Current 100 pA @ 24 VDC Alarm Current, 2-Wirj Up to 86 mA maximum, exact current is Operation determined by alarm current limiting of connected lDC Alarm Current, 4-Wire Operation Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 if/mm (0-610 mimin) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 15° to 122° F (-9° to + 50° C) Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non-condensing Color Frost White 4-7/8" Dia. x 1-7/8° H, mounted in base Dimensions (124 mm x 48 mm); refer to page 3 for detail * ULC listed models are designated with a "C" suffix such as 4098-9601C. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7272-0026:219 for allowable values and/or conditions concerning material presented in this document It is subject to re- examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. t TrueAlarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573. S4098-0015-5 10/02 Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accumulation of dust and dirt. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. (See page 3.) !TTl1flTT1 lii iTI Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke detector spacing of 30 ft (9.1 m) may be used as a guide. For detailed installation information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). Sensitivity Selection. The 4098-9601 standard sensitivity detector is recommended for most applications. When a special application for a reduced sensitivity detector is required, the 4098-9605 should be considered. Consult your local Simplex product supplier for assistance in determining the proper selection. dLmt SIcrtir Smoke Detectors script ion Sensitivity Compatibility 9601 TrueAlarm Photoelectric Detector 2.8%/ft (standard) Compatible with bases: 4098-9788, 4098-9682, and 3.5%/ft 4098-9683 Compatible Bases iel es Dcription Details 4098-9788 2-Wire Base with connections for IDC and LED connections are screw terminals for in/out wiring, çRemote Alarm LED Indicator 18 to 14 AWG 4-Wire Base with Auxiliary Alarm Relay Ratings, Single Form "C", For Suppressed Loads: Relay Contacts and connections for Power limited, 3 A @ 28 VDC; Non-power limited, 3 A @ 120 VAC 4098-9682 Remote LED Alarm Indicator Wiring Connections (In/Out where required): NOTE: Requires external 24 VDC for operation Relay contacts and IDC wiring, color coded 18 AWG leads; LED wiring, screw terminals for 18 to 14 AWG 2-Wire Base with Auxiliary Alarm Relay Ratings, Dual Form "C", For Suppressed Loads: Relay & connections for Remote LED Power limited, 1 A 28 VDC; Non-power limited, 1/2 A @ 120 VAC Indicator 4098-9683 NOTE: Must be connected as the only Wiring Connections (In/Out where required): device on the IDC to ensure relay Relay contacts and IDC (-), color coded 18 AWG leads; operation. IDC (+) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories Model Description - Details Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes 4098-9832 Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098-9788, -9682, & -9683 4098-9830 Remote LED Indicator Mounted on single gang stainless steel plate 2098-9739 Encapsulated Dimensions: 2-1/2"x 1-1/2" X 1" Required for 4-wire circuits using 24 VDC End-of-Line Relay (64 mm x 38 mm x 25.4 mm) 4098-9682 base, one per circuit; select mounting type as required; wiring is Mounted on single gang 2098-9735 Plate Mounted stainless steel plate color coded 18 AWG wire leads * Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm2; 14 AWG = 2.08 mm2 S4098-0015-5 10/02 Detector Status LED Indications I LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal, sensitivity is within None compensation range LED pulses quickly, 6 times in 3 seconds, Alarm is initiated More sensitive, out of normal then turns ON compensation range Cleaning or other service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required * Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual 574-709 for further test and maintenance information. Dimensions and Reference Information 1/4" (6.4 mm) 6-3/8" (162 mm) _ I 4 4098-9832 Adapter Plate i go 4-7/8" (124 m Base height 11/16" (17 mm) / 1-7/8" / (48 mm) IL LED Status Indicator (with clear lens) 4098-9601 & -9605 Dimensions Mounted on Base ALARM 0 Diplex 4098-9830 Remote LED Indicator (not to scale) S4098-0015-5 10/02 4" (102 mm) square box 14" (102 mm) octagonal box Mounting Information (Electrical boxes are supplied by others.) Electrical Box Requirements: Without iI (base 4098-9788): 4" octagonal or 4" square, 1-1/2" deep Single gang, 2" deep With relay (bases 4098-9682 and 4098-9683): 4" octagonal, 1-1/2" deep, with 1-1/2" extension ring 4" square, 1-1/2" deep, with 1-1/2" extension ring Surface mount reference 1-1/2" (38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4" (6.4 mm) maximum recess 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and to 4" square flush mount boxes 4098-9682 and 4098-9683 include a relay module that mounts in base electrical box Smoke Detector Bases 4098-9788, 9682, & -9683 4098-9601, -9605 Smoke Detector Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of T,vco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). BeSirriplex TEPG-US• 91 Technology Drive • Westminster, Massachusetts• 01441-0001 USA S4098-0015-5 10/02 02002 TEPG-US (a Tvco company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:222 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Models 4098-9682, 4098-9683, 4098-9788 and 4098-9684 detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:219 Page 1 of 1 CATEGORY: Photoelectric Smoke Detectors LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Model 4098-9601, -9601TSP, -9602, -9602TSP, -9605, -9605T5P; *GsA40989601 *..9602 and *..9605 photoelectric type smoke detectors. Models 4098-9602, -9602TSP; and *GsA4098..9602 employs an integral 135°F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector and not intended for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed system description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with listee's listed Models 4098-9682, - 9683 or -9788 detector bases *(CSFM Listing No. 7300-0026:222) and separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager f3Simplex TrueAlarm® Smoke Detectors UL, ULC Listed; FM, CSFM, Duct Detector Housings with TrueAlarm Photoelectric and MEA (NYC) Approved* Detector for 2-Wire or 4-Wire Operation I1tuii* Compact air duct detector housing with clear cover to monitor for the presence of smoke Includes factory installed TrueAlarm photoelectric smoke detectort and features: On-board TrueAlarm sensitivity drift compensation and dirt accumulation tracking Multi-function status LED indicator Magnetic test that initiates an alarm and provides detailed diagnostic information Clear cover allowing visual inspection Test ports provide functional smoke testing access with cover in place UL listed to Standard 268A Model availability: 4098-9685, 2-Wire standard operation 4098-9688, 2-Wire with supervised control for a single remote relay (relay included) 4098-9686,4-Wire operation with supervised control for multiple remote relays (includes one remote relay) Mounts to rectangular ducts or round ducts Minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetically operated functional test: Initiates alarm and displays dirt accumulation status using the detector status LED Assists with maintenance priorities by categorizing detector status and identifying dirty detectors Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Red alarm LED (4098-9830) Test stations with LED(s) and keyswitch (refer to page 2 for compatibility) Relays for remote control applications * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. ULC listed models are designated with a "C' suffix such as 4098-9685C. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarrn smoke detector operation is protected by one or more of the following US Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,552,765; 5,710,541; D383,407; 0388,352; D392,573. Duct Detector Housing, Front View rr & 0 0 & & & 4098-9830 4098-9834 4098-9835 Remote Alarm Indicators and Test Stations lntrndiictinn Operation. Simplex® air duct smoke detector housings provide a TrueAlarm smoke detector for monitoring air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke detector mounted in the housing. These duct detector housings with smoke detectors are compatible with Simplex fire alarm control panels that provide conventional two-wire or four-wire initiating device circuits (IDCs). lrn.u1:ETIF1 Each supports a remote red alarm LED or a remote test station with LED(s). Models with relay output provide relay coil wiring supervision that will transfer a trouble to the DC if supervision is lost. 2-Wire Model 4098-9685 provides basic smoke detection for applications that do not require a remote relay. Power is from the IDC. 2-Wire Model 4098-9688 provides a supervised relay output for connection to a single 4098-9841 relay. This model is powered from the IDC and requires connection as the only device to ensure relay operation. 4-Wire Model 4098-9686 provides a supervised relay control output that can control up to 15, PAM-SD control relays. Relay supervision troubles are indicated by a yellow LED on the interface board. (Resettable 24 VDC is required, see page 4.) Remote test station 4098-9835 is available for use with this model to provide a test keyswitch, a red LED alarm indicator and a green power-on LED. S4098-0029-4 10/2003 Duct Detector Selection Chart Duct Smoke Detector Housing with Photoelectric Detector* Model Description Compatibility 4098-9685 2-Wire Duct Detector, standard operation No relay(s) 2-Wire Duct Detector with supervised single remote relay output; includes one 4098-9841 relay; NOTE: Must be only device on Supplied relay is required Remote LED 4098-9688 IDC for proper relay operation; (When used with the Simplex for proper operation indicator and "high 4004 or 4005 fire alarm control panel, connect to current" test stations IDCs only) below per -Wire Duct Detector with supervised multiple remote relay output, Up to 15 total PAM-SD 4098-9686requires =4 resettable 24 VDC fire alarm power and relay end-of-line relays (additional relays are resistor; includes one PAM-SD relay ordered separately) LED Indicator and Remote Test Stations (Select one if required) Each assembly is on a single gang stainless steel plate, wiring is 18 AWG (0.82 mm2 ) color coded wire leads L Model Description Compatibility Mounting 4098-9830 Red LED alarm indicator 4098-9685 4098-9688 Use single gang box, 3" H x 2" W x 2" D 4098-9834 Test Station with keyswitch and red LED alarm indicator (turning switch to "TEST" initiates alarm for system testing) 4098-9686 (76 mm x 51 mm 4098-9835 Test Station with keyswitch, red LED alarm indicator, and green 4098-9686 only x 51 mm) power-on LED Epoxy Encapsulated Remote Relays (wiring is 18 AWG (0.82 mm2 ) color coded wire leads) [Micll Description Compatibility Miting_ J 4098-9841 Relay, dual Form C (1/2 A 120 VAC); 4098-9688 only, included with 4098-9688 Refer to pages 3 I and 4for one maximum Locate relays within 3ft(1 m) of device Relay, single Form C (10 A @ 120 VAC); order additional relay 4098-9686 only, being controlled, per PAM-SD separately from Air Products & Controls, Ltd.; information connect up to 15 NFPA 72 one included with 4098-9686 1 * Each duct housing includes an internally mounted model 4098-9601 TrueAlarm photoelectric detector and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Overall Duct Width Tube Required Suggested Cut Length (305 mm) 2098.9796 1/2 in. (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2 in. (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2 in. (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2 in. (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2 in. (51 mm) longer than duct width TrueAlarm Detector Status LED Indications LED Indication Status Pulses approximately every 4 seconds Normal - Steady On I Alarm Detector LED Response to Magnetic Test ** F LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal, sensitivity is within None compensation range LED pulses quickly, More sensitive, out of normal 6 times in 3 seconds, then turns ON Alarm is initiated compensation range Cleaning or other service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required Testing requires placing a magnet at the designated location on the duct housing cover for 4 seconds and referring to the response from the red LED status indicator on the detector. Refer to Installation Instructions 574-776 for further test and maintenance information. S4098-0029-4 10/2003 NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. - 1-3/8(289 (Magnetic test area (Exhaust tube access hole) Conduit (by othei)) x IRLI& x Metal plate with dual holes for 3/4" (19 mm) conduit, plug FSt-atus LED_ supplied for unused hole \N4098-9601 Smoke detectOr Yellow LED, relay control trouble (Sampling tube mounted in base (supplied) lindicator (4098-9686 only) access hole 4lI1. WiringVrruriL AL (Stationary baffle (builti (Captive fastening screws (4) - - - - Mount as shown (preferred) or (Transparent cover) ted detector area] with electronics area located to the LEFT or UP ONLY 3-3/8" IIj4U_ii (86 mm) ' 13/16" (21 mm) Duct wall Test ports (2) provided Samplingtube,ordered [separately per duct width for measuring airflow and for aerosol injection lExhaust tube (supplied) End View with Duct and Tubes Duct housing [18__ Round duct outlin -------(mmum diameter) (minimum width) (!sttube ,48"Squareductouii1 S S J hole alignment 1 with holes facing into airflow (template is I Sampling tube, keyed for proper I provided for proper tube installation) Remote Relays NOTE: MOL nt in separate electrical box within 3 ft 1 m) of device being controlled per NFF'A 72 r 1-1/4' 1/2' (13 mm) 1H 2-3/8" (60 mm) ( 4098-9841(1/2 A@120 VAC)] 13/16" (21 mm) IL (33 mm) 1-3/16" (30 mm) [PAM-SD (10 A@ 120 VAC)) 3 S4098-0029-4 10/2003 Duct Detector Location Reference Exhaust Detector Damper OK Return Air Do not locate detector here Return air damper I Ii Supply Air Do not locate i-liter " Detector detector here bank OK Bend or other obstruction - Return air. 9 6 Duct inlet 6 Duct widths idths " minimum minimum Preferred Duct Detector Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standardfor the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Exhaust Fresh air Specifications 11 Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 1400 F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Black base with clear cover Tw Wire 9peratlon Models 4098-9685 and 4098-9688 * Operating Voltage 118-32 VDC, from compatible IDC 4098-9685 (no relay) Standby Current 1100 tA @ 24 VDC Alarm Currenfl \ Standby Curi(ent 2.7 mA @ 24 VDC (includes rel4 supervision 4098-9688 Alarm Currt 140 mA maximum @ 24 VDC ) (with single relay control) Relay Cool onAmamum I".J I ; JflIy one Relay Rating Dual Form C, 1 A © 28 VDC, 1/2 A @ 120 VAC, Resistive 4098-9688 per IDC RelayLocation 100 ft (30 m) maximum to relay coil, relay must be within 3 ft (1 m) of device on being controlled per NFPA 72 Four Wire Operation Model 4098 9686 Reqwres Resettable and Fused 24 VDC from Fire Alarm Power Supply Operating Voltage 18-32 VDC (24 VDC nominal) Standby Current 12 mA @ 24 VDC, 32 mA @ 24 VDC with 4098-9835 Test Station Alarm Current 45 mA @ 24 VDC, 65 mA @ 24 VDC with 4098-9835 Test Station Add 15 mA @24 VDC per PAM-SD relay - Supervised Remote Relay Control Sinale For use with relay PAM-SD, quantity of 15 maximum, distance of 500 ft (152 m) maximum, requires 10 kQ, 1/2 Wend-of-line resistor C. use witK Model 409R-86 Only Coil Current 15 mA @24 VDC, up to 15 maximum per relay control output Relay Contacts, Resistive Ratings 7 A @ 28 VDC; 10 A Q 120 VAC; 250 jsA @ 5 VDC Location Distance 500 ft (152 m) maximum to relay coils, relays must be within 3 ft (1 m) of device being controlled per NFPA 72 Remote Alarm LED (4098-9830, -9834, & -9835) 1.7 mA, no impact to alarm current Remote Alarm LED and Test Station Distance 1250 ft (76 m) maximum Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster. Westminster, MA - 0144 1-0001 - USA S4098-0029-4 10/2003 .Simplex www.tycosafetyproducts-usa-wm.com © 2003 Tyco Safet-i' Products Westminster. All rights reserved Al/ specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:241 Page 1 of 1 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441*0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4098-9755, *4098..9755 *4098..9755TTp 4098-9756, *4098..9756T5p *4098..9756up 4098-968 098-968 098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager SimplexGrinnell LP 9855 Carroll Canyon Road SanDiego,CA 92131 tqco /Fire & / SimplexGrinnell Tale: (858) 740-0100 / Security Fax: (858) 740-0156 www.simplexgrinnell.com Contractor License # 802591 * * * Business Information * * * SIMPLEX GRINNELL L P 6952 PRESTON AVE STE A LIVERMORE, CA 94550 Business Phone Number: (925) 273-0100 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2005 * * * License Status * * * This license is current and active. All information below should be reviewed. * * * Classifications * * * FMI Description ELECTRICAL IF]IFIRE PROTECTION CONTRACTOR * * * Certifications * * * Description RL - (for bidding purposes * * * Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 81880913 in the amount of $10,000 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2004 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL(1): This license filed Bond of Qualifying Individual number 81880915 for RONALD GILBERT MAYLE in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 BOND OF QUALIFYING INDIVIDUAL(2): This license filed Bond of Qualifying Individual number 81880914 for FRANKLIN MICHAEL BROWN in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 * * * Workers Compensation Information * * * This license has workers compensation insurance with the AMERICAN HOME ASSURANCE COMPANY Policy Number: RMWC6610498 Effective Date: 10/01/2005 Expire Date: 10/01/2006