Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; ; FA120010; Permit12/5/24, 11:04 AM FA120010 Permit Data City of Carlsbad Fire Alarm Permit 2525 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 1563020900 Lot #: 0 Reference No.: Permit No: FAI200I0 Status: APPROVED Applied 2/9/2012 Approved: 3/14/2012 Issued: 3/14/2012 PC #: Inspector: Project Title: ROBINSONS MAY T.I.-SPRINKLER MONITORING Applicant: SIMPLEX GRINNELL 3568 RUFFIN RD SAN DIEGO CA 858-633-9100 Owner: PLAZA CAM INO REAL C/O WESTFIELD PROPERTY TAX DEPT P0 BOX 130940, DEPT WFLD CARLSBAD, CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 257 0 257 0 about:blank ill SimplexGrinnell LP 9855 Carroll Canyon Road II San Diego, CA 92131 tLICI3/Fire & /SiniplexGrinne Tele: (858) 740-0100 SecurIty Fax: (858) 740-0156 www.simplexgrinnell.com FIRE ALARM PRODUCT SUBMITTAL PROJECT: Westfield Plaza Camino Real Robinsons-May Sprinkler Monitoring 2525 El Camino Real Carlsbad, CA 92008 2/2/2012 REV.#: 0 PROJECT #: tqco IF/re & /SimplexGrinnell I Security I SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com ITEM MODEL NO. DESCRIPTION C.S.F.M. NO. A 4010-9101 4010 FACP 7170-0026:226 B 2081-9274 10 Amp/Hour Batteries N/A C 4606-9101 LCD Annunciator 7120-0026:179 D 4098-9792 Addressable Detector Base 7300-0026:217 4098-9714 Photo Detector 7272-0026:218 E 4090-9001 Addressable Monitor 7300-0026:223 F 4906-912 Horn/Strobe Multi-cd 7125-0026:317 2/2/2012 REV.#: 0 PROJECT#: S. Simplex TrueAlarm® Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved; Model 4010 Fire Alarm Control Panel for TrueAlarm MEA (NYC) Acceptance* Analog Sensors and IDNetTM Addressable Devices Ittii .i-. Standard features include: Up to 250 addressable TrueAlarm sensor or addressable device points using IDNet communications that operate with either shielded or unshielded twisted pair wiring** Four, 2 A notification appliance circuits (NACs) with solid state current protection Power supply/battery charger with 4 A available for NACs and auxiliary power Internal event reporting DACT module (standard on models 4010-9101, 4010-9102, & 4010-9150) UL listed to Standard 864 Installation convenience features: Power-limited design provides electronic modules on a one-piece chassis with up-front terminal blocks for wiring access Compact NEMA I rated cabinet is available in beige or red and can be pre-shipped for early installation Setup, programming, and maintenance features: Device level ground fault search, locate, and isolate Auto Program for general alarm operation TrueAlarm individual analog sensing with front panel information and selection access "Dirty" TrueAlarm sensor maintenance alerts, service and status reports including "almost dirty" Default TrueAlarm sensor device type operation TrueAlarm sensor peak value performance report Duplicate address error detection Front panel or PC programming WALKTESTTI silent or audible system testt Software verification simulation mode Supports the following IDNet devices: Addressable manual stations; TrueAlarm sensor bases, duct housings, and isolator bases Quad-state zone adapter modules (ZAMs) for initiating device monitoring Quad-state line powered individual addressable modules (JAMs) for initiating device monitoring and relay control 4009 IDNet NAC Extenders and TrueAlertov Addressable Controllers and accessories Available option modules include: Door mounted 24 LED annunciator (std. on ULC models) Network connection, or Point Reporting DACT Class A, NAC adapter module RS-232 ports for printer and maintenance PC Expansion power supply; Auxiliary Relay Module or City Interface Equipment for Suppression Release Applications (refer to data sheet S4010-0003) Compatible with Simplex® auxiliary panels: 4003 Voice Control Panel 4081 Battery Cabinet with charger for 50 Ah batteries 4010 Fire Alarm Control Panel (with standard door) DAstrintir TrueAlarm fire alarm control panels have the ability to provide location accuracy for monitoring and control. When equipped with TrueAlarm analog sensing for smoke and heat detection, the processing power of the control panel also has the ability to analyze conditions at each location to provide accurate detection with significantly reduced maintenance costs. The 4010 TrueAlarm Fire Alarm Control Panel has been specifically designed to provide addressable operation and analog detection in a cost-effective package for application sizes that previously were considered only appropriate for conventional zoned monitoring. Installation and Service Ease. The 4010 mounts on a single chassis for quick installation and removal. Terminal blocks are large and up-front for easy access and inspection. Optional modules are easily and quickly installed, and programmed as required. The 4010 cabinet provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting. Smooth cabinet surfaces are provided for locally cutting conduit entrance holes exactly where required. 4010 cabinets and electronics can be ordered separately, allowing early cabinet installation. Ground Fault Assistance. Ground fault problems often occur during installation. The 4010 provides isolating circuitry, control of isolator bases, and software-control led sequencing to isolate ground faults to specific identified locations. This assistance helps the installer to accurately locate the wiring problem for quicker repair. * Refer to page 6 for listing details. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. See CSFM Listing 7170-0026:226 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; Contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. TrueAlarm analog smoke detection and IDNet addressable devices are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,552,765; 5,552,763; DES. 377,460; 4,796,025; 5,966,002; and 6,034,601. t WALKTEST system test is protected under U.S. patent #4,725,818. S4010-0001-12 8/2009 Extensive Feature List. The 4010 Fire Alarm Control Panel provides access to an extensive feature list that includes: Providing easy and powerful operator information with a logical, menu-driven display Extensive and automatic diagnostics for maintenance reduction History Logs available from the LCD or capable of (optionally) being printed Software Verification, allowing detailed logic programming simulation to be conducted without activating connected outputs Control Panel (or service PC) label editing Password access control Auto Program Quick Configuration (Quick-CFIG) of connected modules and IDNet devices for general alarm operation to quickly get the system up and running E101101 ']fl '1 1TT11 rrn I I] tt!IiD11 ti M1 ri Convenient Status Information. With the locking door closed, a window allows viewing of the status display. The 4010 status panel provides a two line by 40 character, super-twist LCD information display and eight status LED indicators as shown in the illustration below. From this display, the LED indicators will describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door will provide access to the control switches and allow further inquiry by scrolling the display for additional detail. (Refer to control panel functional illustration below.) WALKTEST Diagnostic Operation Mode. The patented WALKTEST process allows a single person to perform system test. The system records test inputs such as intentional alarms or trouble and either logs the response (silent WALKTEST operation) or outputs a brief, recognizable audible notification signal (audible WALKTEST operation). Extended Operator Control Panel Functions FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on until reset THREE PROGRAMMABLE LEDs custom labeling (labels insert into 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 40 characters for custom label information L0vde a pocket), the top two LEDs are FIRST ALARM DISPLAY: Operation can be selected for maintained display of first 1 selectable as red or yellow, the bottom alarm until acknowledcied LED is selectable as green or yellow -- /SYSTEM IS NORMAL 15'rri Mon 17—Aug-09 CONTROL -• - -- - .. SYSTEM RESET restores PANEL VIEW with - control panel to normal when 4010 door closed all alarmed inputs are returned to normal -TAI ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge and silences the operator panel and all annunciator tone-alerts L--------------------- -------------- NINE EXTENDED FUNCTION KEYS (accessible with door \ open) select and scroll through display prompts for locating \ additional system information, performing maintenance \ functions, or for front panel programming SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts ALARM SILENCE causes audible notification appliances to be silenced, used after evacuation is complete and while alarm source is being investgated TROUBLE ACK acknowledges system troubles, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts S4010-0001-12 8/2009 TrueAlarm heat sensors can be selected for rate-of-rise detection as either 15° F (8.3° C) or 200 F (11.10 C) per minute with an independent fixed limit of 135° F (57° C) or 155° F (68° C). TrueAlarm heat sensors can also be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (00 C to 680 C). This feature can provide freeze warnings or alert to HVAC system problems. To additional IDNet devices, up to 250 total I Modular TrueAlarm TrueAlerl Addressable Controller sensor with base Supervised lAM Modular TrueAlarm sensor with IDNet isolator base Addressable station 4009 IDNet NAC Extender Quick-Connect Monitor Z.AMs and TrueAlarm sensor I Relay lAMs 4010 Fire Alarm Control Panel with annunciator door I111 4010 Control Panel with Typical IDNet Devices L!J..IIiI.111 E*L1 ii. I II rniiii 'i'i 1!J TrueAlarm operation gives the 4010 system the ability to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 (National Fire Alarm Code) requirement for a test of the sensitivity range of the sensors is fulfilled by the TrueAlarm ability to maintain the sensitivity level of each sensor. Modular TrueAlarm sensors use the same base and different sensor types (photoelectric smoke sensor, or heat sensor) can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. Il']vrit**iirTTi Overview. The 4010 provides IDNet addressable device communications. Using a two-wire circuit, individual devices such as manual fire alarm stations, TrueAlarm sensors, and sprinkler waterfiow switches can be directly connected (or interfaced) to the IDNet controller to communicate their identity and status. This addressability allows the location and condition of the connected device to be displayed on the 4010 panel LCD and on system annunciators. Additionally, control circuits (fans, dampers, etc.) may be individually controlled by using a relay JAM (individual addressable module). The 4009 IDNet NAC Extender or the TrueAlert Addressable controller can be controlled for local or remote notification appliance expansion. (Refer to compatible device lists on document S4090-0011 and to individual device documentation for further details.) Capacity. A total of 250 addressable monitor and control points may be intermixed on the same pair of wires. By using Zone Adaptor Modules (ZAMs) or Individual Addressable Modules (JAMs), conventional initiating devices can be connected to the IDNet circuit. IDNet Addressable Operation. The IDNet controller continuously interrogates each addressable device on the communication channel for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Sophisticated poll and response communication techniques ensure supervision integrity and allow for "T-tapping" of the circuit for Class B operation. Wiring Requirements. Refer to the specifications chart below. Distances are for shielded or unshielded wire. Shielded wire may provide protection from unexpected sources of interference and may be required for some applications. Wiring Specifications Size 18 AWG (0.82mm2 ) Wire Preferred Shielded twisted pair (SIP) Unshielded twisted pair (UTP) Acceptable Farthest Distance from Control Up to 2500 feet (762 m) Panel to Device Total Wire Length Allowed With Up to 10,000 ft (3 km). "I"_ Taps _for Class B_Wiring Ml iW_1 F II4iI lI TrueAlarm System Operation. IDNet communications are used for TrueAlarm smoke and temperature sensors. Every four seconds, smoke sensors transmit an output value based on their smoke chamber condition. The 4010 CPU maintains a current value, peak value, and an average value of each sensor's output. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Programmable Sensitivity. The sensitivity of each sensor can be field programmed at the 4010 Control Panel for different levels of smoke obscuration (in percent) or for specific heat detection levels. In order to evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read and compared to the alarm threshold directly in percent. S4010-0001-12 8/2009 Printer (Simplex model 4190-9013) / 7 Local maintenance computer \ 4--- lIIl!I1sI \ 4010 Fire Alarm \One connection type per 4010, Control Panel selected by module choice; max. -U wiring distance is 300 ft (91 m) @9600baud Remote authorized maintenance computer connected via dial-up Service Modem Connection TrueAlarm Information Details True Alarm sensor data can be displayed on the system LCD, on a remote maintenance PC, or printed on a remote printer. With the proper operator access, a TrueAlarm Service Report can be generated to list the specific details of each TrueAlarm device. This report, as well as the Status Report can either be displayed on the remote maintenance PC or captured permanently by using a remote 80 character printer. Status and Service Reports. The report samples below illustrate the format provided on either the remote maintenance PC or a printer. This information is available at the system LCD by identifying the specific point of interest and reading one point at a time. Compatible Printer. Model 4190-9013 is a UL Standard 864 listed 80 column, 24 pin dot matrix printer (refer to data sheet S4190-001 1). RS-232 Connection Options (refer to module selection on page 6) TrueAlarm Status and Service Report Samples Simplex 4010 Fire Alarm System Page 1 REPORT 3 : TrueAlarm Status Report 2:43:03 pm Mon 09-Mar-09 Zone Sensi- Almost Name Custom Label tivity Device Status Dirty Ml-1 ANALOG PHOTO CLEAN ROOM 0.5 % NORMAL M1-2 ANALOG ION CLEAN ROOM 1.3 % NORMAL M1-3 ANALOG PHOTO MAIN LOBBY 2.5 % NORMAL *YES* Ml-4 ANALOG PHOTO CONFERENCE ROOM 1 2.5 % NORMAL Ml-10 HEAT DETECTOR GARAGE 135 F NORMAL Ml-ll ANALOG PHOTO KITCHEN 3.7 % NORMAL *YES* END OF REPORT Typical TrueAlarm Status Report Information Printout and/or Maintenance PC Screen Simplex 4010 Fire Alarm System Page 1 REPORT 4 : TrueAlarm Service Report 2:56:09 pm Mon 09-Mar-09 Dev Alarm Avg Current/ Peak/ State Num Custom Label at: val % alarm % alarm 1 ANALOG PHOTO - CLEAN ROOM 0.5/ 83 67 68/ 1% 72/ 10% NOR 2 ANALOG ION - CLEAN ROOM 1.3/209 94 97/ 2% 101/ 1% NOR 3 ANALOG PHOTO - MAIN LOBBY 2.5/185 117 117/ 0% 125/ 42% NOR 4 ANALOG PHOTO - CONFERENCE ROOM 1 2.5/161 93 93/ 0% 93/ 0% NOR 10 HEAT DETECTOR - GARAGE 135F/253 --- 63/-67F 66/ 69F NOR 11 ANALOG PHOTO - KITCHEN 3.7/216 116 116/ 1% 110/ 36% NOR END OF REPORT Typical TrueAlarm Service Report Information Printout and/or Maintenance PC Screen 4 S4010-0001-12 8/2009 FITT FTV I TT I 'i *i N2 Communications for Serial Annunciator Control. Control for up to 6 remote Simplex Annunciator products including 24 Point I/O Module, and LCD Annunciator. Includes extensive troubleshooting diagnostics. (See list in next column for compatible devices.) Access Port. RS-232 service port for connecting PC tools for service diagnostics and for programming the CPU Flash EPROM memory. IDNet Addressable Communications Channel. Addressable channel provides communications for up to 250 remote addressable devices, including TrueAlarm analog sensors and isolator bases (see details on page 3). Four NACs. Class B output is standard, rated for 2 A 24 VDC nominal, with solid state current protection. Class A operation is optional with the addition of an adapter module. NAC operation can be selected for "on-until-Silence" or "on-until-Reset," and can be Continuous, Temporal pattern, or March Time pattern. (March Time is selectable for 20 bpm or 120 bpm for conventional appliances; or 60 bpm for SmartSyncTM appliances.) NACs are individually selectable to control Simplex synchronized strobes or for Simplex SmartSync control that provides separate horn and synchronized strobe control using a 2-wire circuit. (SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789.) Two Auxiliary Output Circuits. Operation is programmable for trouble, alarm, supervisory, or other fire response functions. Output is one Form "C" dry contact each, rated 2 A @ 24 VDC. An optional relay kit is available for switching up to 0.5 A at 120 VAC. Standard Power Supply. Output is rated 4 A for "Special Application" appliances and for "Regulated 24 DC" appliance power. (Special Application appliances include Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, horn/strobes, and speaker/strobes. Seepage 7for additional information.) Internal system power is provided separately, allowing the 4 A to be available for NAC and auxiliary power tap functions. Over-current protection is solid state and self-resetting. Auxiliary Power Tap. Provides up to 0.5 A of the standard power supply voltage, over-current protected. Compatible uses include power for: remote LCD annunciators, 24 Point I/O modules, sensor bases and duct housings that require external power, and addressable devices requiring external power. Battery Charger. Capable of charging up to 25 Ah sealed lead-acid batteries (4010 cabinet mounted). A recharge time of 24 hours is typical with stable 120 VAC input. For applications requiring larger batteries, external charger/cabinet assemblies are available. A depleted battery cutout feature is programmable to advise and/or to reduce current when battery voltage is low. rem 110 rivr m r (The 4010 is available with a Simplex Network Interface. 4010 points can be declared "public.") Network Interface, Modular Media. Available for wired connections or fiber optic. Require separate media modules. May be both wired, both fiber optic, or one of each. JTTTi1. I :i i I1L'F rn (171Ij Network Interface, Fixed Media. Available for wired applications. DACT, Point Reporting Module. Provides serial output information that can send location details to a remote receiving station. DACT, Event Reporting Module. For applications where simple event status information is required (Alarm, Trouble, Supervisory, and AC power failure). Dual RS-232 Module. Available for interfacing to a printer and a maintenance PC. Single RS-232 Module with Service Modem Connection. Provides one port dedicated for connection to a printer, and a second port dedicated for dial-in from a service computer, typically located off-site. With an off-site computer, programming changes and system diagnostics can be performed remotely, reducing service time for repair or reprogram. Security is maintained by password protection. jri r. r mu Jj rr m r 4 A Expansion Power Supply provides two taps of 2 A each, 28 VDC, filtered, non-regulated. Output rating is 4 A for auxiliary power, 4 A for "Special Application" appliances and 2 A for "Regulated 24 DC" appliance power. Battery Meter Module provides panel mounted ammeter and voltmeter for power supply monitoring. Dual Circuit Class A NAC Adapter Module mounts on the main 4010 printed circuit assembly and provides the additional circuitry needed for Class A operation. Dual Circuit City Connect Module provides the interface required for direct wired reporting to conventional city connection circuits. (Available with or without disconnect switches.) Expansion Power Distribution Module provides two additional termination points for the 0.5 A auxiliary power output, or for one tap of the expansion power supply. Relay Option Module provides three relays, one each for Alarm, Supervisory, and Trouble. Relay contacts are selectable for normally open or normally closed and are rated 2 A @ 32 VDC maximum. 10 fr1' 111 11I ii !T1 !iFT rfl ! Up to six of the following modules may be connected to the Simplex N2 serial communications bus. 4606-9101 LCD Annunciators provide remote acknowledge, reset, and alphanumeric status display. First Alarm display will work same as for the panel when selected (see page 2). (Refer to data sheet S4606-0001.) 24 LED Annunciator Doors are standard on ULC listed models and are available as door-only assemblies for electronics only packages or other aftermarket applications. This option uses the 24 Point I/O module with all points pre-assembled as LED outputs, with individual labels and each LED is selectable as red or yellow. 4605 Series 24 Point 110 Modules are available for remote mounting and provide 24 points that can be programmed as either general purpose switch inputs or system controlled outputs. Typical applications are for remote annunciators and monitoring and control of other related processes. (Refer to data sheet S4010-0002.) S4010-0001-12 8/2009 Category Model Description Voltage Color 401 0-91 01 UL Listed 4010 Fire Alarm Control Panel with: door, cabinet, power 120 VAC Beige 4010-9102 supply/battery charger, IDNet interface, 4 NACs, 2 programmable Red 4010-9201 auxiliary relays, and external N2 communications interface; 4010-9101 Beige and 4010-9102 include internal common event reporting DACT 240 VAC Control Panel 4010-9202 Red Assembly 4010-9101C English ULC Listed 4010 Fire Alarm Control Panel; same as above 120 VAC Beige (select one) 4010-9101 CF French except: with 24 LED Annunciator door; and without DACT 4010-9150 UL Listed 4010 Fire Alarm Control Panel, Electronics Only; for pre-shipped 4010-9150C ULC English cabinets, requires door and cabinet ordered separately; 120 VAC input; 4010-9150CF Listed I French 4010-9150 has event reporting DACT; C & CF suffix models delete DACT Optional Expansion Slot Features (two slots are available, select modules as required) Category Reporting and Network Modules Model 4010-9810 Description DACT Module (Common Event Reporting) Includes two, 7 ft (2.1 m) long RJ45 cables DACT Module (Point Reporting) 4010-9816 (select one) 4010-9821 Network Interface Module with fixed, wired connections 4010-9817 Network Interface Module, Modular; requires 2 (In/Out) media modules (see below) Media Modules 4010-9818 Network Wired Media Module Media modules mount on the 4010-9817 module Network Fiber Optic Media Module without impact to slot allocation space. 4010-9819 RS232 Communications 4010-9811 Dual RS-232 Interface Module (select one) 4010-9812 Single RS-232 Interface Module with Service Modem connection Chassis Mounted Expansion Modules (select as required) Category Model Description Expansion Power Supply 4010-9813 120 VAC input 4 A Expansion Power Supply; rated 4 Afor "Special Application" appliances; 4010-9823 (select one) "Regulated 240 VAC input rated 2 A for 24 DC" appliance power 4010-9820 Battery Meter Module (ammeter and voltmeter) Optional Features (select one) 4010-9825 24 VDC Expansion Power Distribution Module, provides two additional termination points for an expansion power supply tap or the auxiliary power output 4010-9806 Dual Circuit Class A NAC Adapter Module, two maximum Optional Features (select as 4010-9809 Dual Circuit City Connect Module indicated) 40109829* Dual Circuit City Connect Module w/o disconnect switches Select one I maximum 4010-9803 1 Relay Option Module Accessories Category Model 4010-9826 Description 120 VAC Auxiliary Relay Kit, allows one auxiliary relay to control up to 0.5 A @120 VAC, select as required; 2 maximum Optional Features 4010-9830 (CAF) Suppression Release Appliqué, required for suppression release applications; suffix CAF selects a French appliqué 2975-9801 Semi-flush trim, beige, 1-7/16" (37 mm) wide 2975-9802 Semi-flush trim, red, 1-7/16" (37 mm) wide Batteries 2081-9272 6.2 Ah Battery, 12 VDC (required if 2081-9274 10.0 Ah Battery, 12 VDC batteries are internal; select one 2081-9288 12.7 Ah Battery, 12 VDC size; two batteries 2081-9275 18 Ah Battery, 12 VDC; NOTE: This battery size will not allow bottom entry conduit are required) 2081-9287 25 Ah Battery, 12 VDC Cabinets (select one if pre-shipped) 2975-9215 Red Cabinet Dimensions: 22" H x 18" W x 5-3/8" D Beige Cabinet; CF suffix has French labels (559 mm x 457 mm x 137 mm) 2975-9214(CF) Doors (select one for use with 4010-9150) 4010-9858 if pre-shipped or Red Door with dress panel Dimensions: 22" H x 18" W x 5/8" D Beige Door with dress panel; CF has French labels (559 mm x 457 mm x 16 mm) 4010-9857(CF) 40109860* Beige Door with 24 LED Annunciator and dress panel Dimensions: 22" H x 18" W x 1-23/32"D (559 mm x 457 mm x 1 Red Door with 24 LED Annunciator and dress panel 44 mm) [see also S4010-0002] 40109861* * As of document revision date: 4010-9829 is not ULC listed; 4010-9860 and 4010-9861 are listed by UL, ULC, and CSFM; and FM approved; 6 S4010-0001-12 8/2009 14010 Operating Specifications Input Power Requirements AC Input, 120 VAC base models Voltage Range 102 to 132 VAC Frequency 60 Hz Maximum Current 2 A AC Input, 240 VAC base models 204 to 264 VAC 50/60 Hz 1 A AC Input with 120 VAC expansion power supply 102 to 132 VAC 60 Hz 4 A AC Input with 240 VAC expansion power supply 204 to 264 VAC 50/60 Hz 2 A Environmental Operating Temperature Range 32° to 120°F (0 to 49° C) Operating Humidity Range up to 93% RH, non-condensing @ 100.4° F (38° C) maximum Output Ratings : Rated 4 A for "Special Application' appliances and for Standard Power Supply Output "Regulated 24 DC" appliance power; Battery charger for up to 25 Ah sealed lead-acid batteries Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, and Special Application combination horn/strobes and speaker/strobes (contact your Simplex Notification Appliance Reference product representative for compatible appliances) Power for other UL listed appliances; use associated external Regulated 24 DC synchronization modules where required Auxiliary Power Output Tap from Standard Power Rated 0.5 A maximum @ 19.4 to 32 VDC; Supply subtract current used from standard power supply output Rated 4 A for "Special Application" appliances and auxiliary power; Expansion Power Supply Output Rated 2 A for "Regulated 24 DC" appliance power; Two output taps of 2 A each are provided NAC Ratings 2 A each maximum; up to 33 synchronized strobes maximum per NAC Current Ratings for Optional Modules and Remote LCD Annunciator Model 4010-9810 Module DACT (Common Event Reporting) Supervisory Current 40 mA Alarm / Current " 40 mA , 4010-9816 DACT (Point Reporting) 40 mA 40 mA -- 4010-9821 Network, wired communications 125 mA 125 mA 4010-9817 Network Modular, add media cards separately 24 mA 24 mA 4010-9818 Network Wired Media 47 mA 47 mA 4010-9819 Network Fiber Optic Media 36 mA 36 mA 4010-9811 Dual RS-232 75 mA 75 mA 4010-9812 Single RS-232 with Service Modem 100 mA 100 mA 4010-9806 Dual Class A NAC Adapter 0 mA 0 mA 4010-9809 Dual Circuit City Connect 20 mA 36 mA 4010-9829 Dual Circuit City Connect w/o disconnect switches 20 mA 36 mA 4010-9803 Relay Option Module 10 mA 37 mA 4010-9860 4010-9861 & ULC 4010s 24 LED Annunciator door 60 mA 83 mA (all LEDs on) 4606-9101 Remote LCD Annunciator (refer to data sheet S4606-0001) 65 mA 140 mA System Current (supplied separate from power supply output) Base System with: no IDNet devices Supervisory Current** 195 mA Alarm Current** 295 mA 50 IDNet devices 230 mA 330 mA 100 IDNet devices 265 mA 365 mA 150 IDNet devices 300 mA 400 mA 200 IDNet devices 335 mA 435 mA 250 IDNet devices 370 mA 470 mA Current Calculation Intormation: To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. 7 S4010-0001-12 8/2009 ; - - - - - r 20i 1B3 TB4 4010-9809 Meter Module 4010-9806 4010-9806 or-9829 :: or Class A : Class A • : City Module 4010-9825 Module Module 4010 -9803 or 24 VOC Power: - -=- - - -=.- - - Distribution Relay Module Block Or 0 ------------------- © L DO mood 0 0 0 00 0 © 0 : 4010-9813 or 4010-9823 rV Expansion Power Supply L-------------------- © a no Expansion Slots 1 & 2 / .1 - - k_ Typicalconduit entry area (cut holes as required) 18" (457 mm) II IF 0 Ll 21" O0®6000 33 mm -------------------------------- 14-1/2" (368 mm) Battery Area No conduit entry or wiring in this area 4 Shaded area is for non-power limited wiring / Standard 1-19/32"---.- door profile (40 mm) 7-3/32" (180 mm) (159 mm) Annunciator 5-1/2" (140 mm) (19 mm) - door profile - Wall thickness guides for 1/2' (13 mm) wall board Standard Door, -_ 5/8' It mm) thick Wall thickness guides for 5/8" (16 mm) wall board) Annunciator Door, Internal straps are 1-23/32' (44 mm) thick provided for wiring management (2 each side) Door and exposed cabinet dimension - - for semi-flush mount 2-15/32" (63 mm) Knockout screw/nail holes (for semi-flush mount) Wall board position reference for semi-flush mount (5 4010 Module Layout Reference EXTN2 0 IDNOt NAC1 NAC2 NAC3 N*04 F iF Mounting Information POWER I Tyco is ci registered trademark of Tyco l,iie,-,ianotial Services GmbH and is used undei license. Simpler, the Simpler logo. TrueAlarm. WALKTEST IDNet, SmartS mc, and TrneAlert are trademarks of Tyco International Ltd. and its affiliates and are used i,,idei' license. NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA). ,Simplex13 Tyco Safety Products Westminster• Westminster, MA 01441-0001 USA S4010-0001-12 8/2009 www.tycosafetyproducts-usa-wm.com © 20(19 Tvco Safety Pi-oditcis Westminster. All rig/its reserrec/. All spec (fl rations and oilier information slmooc vein current as of document rei'ision date and are subject to change mrhumoui notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION rØi OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE !M LISTING No. 7165-0026:0226 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Simplexl0o Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4010-9101, -9102, -9201, and -9202 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station (protected premises), proprietary (protected premise), waterflow, and sprinkler supervisory service. Suitable for releasing device service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 4010-9101-9102-9201 ,-9202Control Unit 4010-9150 Standard Function I/O 4010-9809-9829 City Circuit Card 4010-9810 Event Report DACT 4010-9816 Point Report DACT 4010-9817 Modular Network Interface 4010-9821 RS-485 Net Interface 4010-9806 Class A Adapter 4010-9811 Dual RS-232 Interface 4010-9812 RS-232 Service Modem 4010-9813 Expansion Power Supply 4010-9814 Suppression Release Kit 4010-9818 Wired Media Module 4010-9819 Fiber Optic Media 4010-9820 Battery Meter Module 4010-9823 Expansion Supply 4010-9824 Suppression Release Kit 2081-9046 Coil Supervision Module 4010-9860-9861 Replacement Door with Annunciator 4010-9803 Relay Module RATING: 120, 220, 240 VAC primary; 24 VDC secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Also suitable for high-rise application when installed with Model 4003 *Rev. 01-15-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructionsafid/ôr'other Date Issued: July 01, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Listing Expires Listing No. 7165-0026:0226 Page 2 of 2 Series Voice Evacuation System (CSFM Listing No. 6911-0026:196). Refer to listee's Installation Instructions Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly from 71700026:226* *Rev. 01-15-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VG operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division iSimpIex Fire Alarm Control Panel Accessories Cabinet Mounted System Batteries; 2081 Series, Sealed Lead-Acid; 6.2 Ah to 50 Ah Rechargeable, sealed lead-acid design: Lead-calcium grid structure Immobilized electrolyte in absorbent separator High reliability dual seal construction Low maintenance, no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size For applications requiring 110 Ah batteries: Refer to data sheet S4081-0002 for 4100U systems Refer to data sheet S2081-0012 for 4100/4120 series system IIi*!.lrM1 Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. I:I,Tfl1 Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Specification Summary Nominal Voltage Rating 12 V/battery Discharge Rating 20 Hour Rate Typical Chart/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. S2081-0006-16 9/2004 Inner cover Absorbent sei used to imrr e1e Lead-calciur C Typical Construction Details Actual appearance will vary with battery size. Cell case (high impact polystyrene) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator S2081-0006-16 9/2004 Battery Specifications Battery Model Capacity @ 20 Hour Width* Depth*Terminals Height with Approximate Discharge Rate Weight* 2081-9272 6.2 Ah 6-1/8" (156 mm) 2-5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah 6" (153 mm) 4-1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6" (153 mm) 4" (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) 5(127mm) 7" (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16(179mm) 26.6 lbs (12.1 kg) typically _for _service) 2081-9276 ("square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9-1/2" (241 mm) 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Simplex Control Panel Model Series (see legend and notes below) Model Capacity 4003 4 4 00 40 04R 4 005 4006& 4009 4010 4100U 4100 &4120 4020 4008 (all models) (2 or 3 bay) (2, 4 or 6-Unit) (2, 4 or 6-Unit) 2081-9272 6.2 Ah / ,f / 2081-9274 10 Ah I 1 1 1 2081-9288 12.7 Ah / / / 2081-9275 18 Ah / Note 3 1 Ext Ext Note 2 2081-9287 25 Ah Note 3 Ext I I I Ext 2081-9271 (rectangular) 33 Ah Note 3 Ext Note 3 1 Ext Note 4 2081-9276 square 33 Ah Note 3 Ext Note 3 1 1 Ext 2081-9296 1 50 Ah Note 3 Note 3 / Ext Ext I = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 Shaded areas = Not applicable NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. S2081-0006-16 9/2004 External Battery Cabinet Compatibility Reference Externally Mounted Battery Battery Cabinets without Chargers Battery Capacity Cabinets fli Chargers (connects to charger in panel) 4081 Model * 20819301** 20819303** Seriest 20819270** 2081-9281 2081-9282 4009-9801 4009-9802 2081-9275 18 Ah 2081-9287 25 Ah 2081-9271 (rectangular) 33 Ah 2081-9276 (square") 2081-9296 50 Ah * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. 1= Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specification Reference Model Description Color Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 20819270* External battery cabinet without charger Red 26-1/2" W x 12" H x 12" D 2081-9301 External battery cabinet with charger 20819302* External battery cabinet without charger and with meters for voltage and current (673 mm x 305 mm x 305 mm) 2081-9303 External battery cabinet with charger and with meters for voltage and current 4009-9801 For up to 18 Ah External battery cabinet without charger, 16-1/4" W x 13-1/2" H x 4-1/8" D batteries with solid door and battery harness, for close-nippled mounting to fire alarm control Beige (413 mm x 343 mm x 105 mm) 4009-9802 For up to 33 Ah 25-3/4" W 20-3/4" H x 4-1/8" D batteries panel cabinet (654 mm x 527 mm x 105 mm) 4081 For up to 50 Ah Companion cabinet with charger for the Beige or 22-1/2" W x16-3/4" H x 8-3/8" D Series** batteries 4010 and 4004R fire alarm control panel Red (572 mm x 425 mm x 213 mm) * Refer to Simplex data sheet S2081-0002 for additional information. ** Refer to Simplex data sheet S4081-0001 for additional information. Trco. Simpler, and the Simpler logo we trw/e,nwks of Trco International Services AG or Its a//i/later i,, the U.S. and/or other comitries. ,,Simplex Tyco Safety Products Westminster • Westminster, MA 01441-0001• USA S20981-0006-16 9/2004 www.tycosafetyproducts-usa-wm.com 02004 Trco So/dr Products Westminster. All rights reserved. All specifications and other in/oI'moflon shown were cws cut or o/docwneut revision (late and are subject to change oil/tout notIce £®Simplex Multi-Application Peripherals and Accessories UL, ULC Listed; CSFM, FM, 4606-9101 LCD Annunciator and MEA (NYC) Approved* for the 4010 Fire Alarm Control Panel Remote LCD annunciator for use with the Simplex 4010 fire alarm control panel LCD readout provides: Two lines of 40 characters each Wide viewing angle, super-twist design LED backlighting Control switches and status LEDs for: Alarm, supervisory, or trouble acknowledge Alarm silence System reset Three programmable LED indicators: Two LEDs are selectable as red or yellow One LED is selectable as green or yellow With provisions for custom labeling Information is transmitted over one twisted, shielded pair (Simplex N2 communications) Tone-alert sounder provides local audible indication Lamp and LCD are functionally tested each time keyswitch is switched on Mounts flush on standard 6-gang electrical box Mounting and trim options: Surface mount box model 2975-9217 (ordered separately) Brushed aluminum trim model 4603-9111 (ordered separately) * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7120-0026:225 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact Simplex for the latest status. SYSTEM Is 010"L 12:02:15 71 4606-9101 LCD Annunciator Description The Simplex 4606-9 101 LCD Annunciator provides remote annunciation using an 80 character, back-lit, alphanumeric, LCD readout. Information is presented in clear, descriptive English language and includes: point status (alarm, trouble, etc.), alarm type (smoke detector, manual station, etc.), number of system alarms, supervisory conditions, troubles, and custom location labels up to 40 characters long. Communications require a single twisted, shielded pair and can also support the 4605 Series 24 1/0 module on the same wire pair (up to six devices total). Alarm, Supervisory, and Trouble conditions are also indicated by dedicated LEDs and a tone-alert audible indication. Each condition has a dedicated acknowledge push-button switch that silences the tone-alert but leaves the LED on until all conditions in that category are restored to normal. Repeated operation of the appropriate acknowledge switch will scroll the LCD display showing activity in the sequence of occurrence. The internal tone-alert also sounds to indicate the operation of any of the push-button switches. Operation All switches on the annunciator are controlled by the "ENABLE" key switch with a key that is removable only in the disabled position. When enabled, notification appliances can be deactivated by pressing the "ALARM SILENCE" switch. Pressing the "SYSTEM RESET" switch restores the system to normal operation. When system activity is normal, the LCD displays the time, date, and "SYSTEM IS NORMAL." © 2000 Simplex Time Recorder Co. All rights reserved. S4606-0001-3 6/00 14606-9101 Operator Information 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions. FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information. LEDs flash to indicate the condition and then when THREE PROGRAMMABLE LEDs acknowledged, remain on steady until reset. each with custom labeling pocket 0/I _ - SYSTEM IS NORMAL ** 12:02:1 5pm Mon 12-Jun-00 'I w & __'' I V~T 0 IT I L'_ 0 Simplex ALARM ACK acknowledges a \ Fire Alarm condition and / \ CONTROL ENABLE KEY SWITCH silences the panel and all / \ controls all switch functions. Key is annunciator tone-alerts / \ \ removable only in disabled position. SUPV ACK acknowledges system supervisory conditions and silences the panel and all annunciator tone-alerts. TROUBLE ACK acknowledges system troubles and silences the panel and all annunciator tone-alerts. SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal. ALARM SILENCE causes audible notification appliances to be silenced, used after evacuation is complete and while alarm source is being investigated. Simplex Time Recorder Co. 2 S4606-0001-3 6/00 4606-9101 LCD Annunciator Specifications General Operating Specifications Voltage 18.9 to 32 VDC, system supplied Normal Operating Current 110 mA (LED backlighting is on) Battery Standby Current 65 mA (during battery backup, LED backlighting is turned off after 30 seconds without switch activity) Alarm Current 140 mA maximum (LED backlighting is on and tone-alert is sounding) Operating Temperature Range 32° to 120° F (0° to 49° C) Operating Humidity Range up to 93% RH, non-condensing at 100° F (38° C) Communications Type N2 externalannunciator communications line from 4010 Fire Alarm Control Panel Capacity Wiring Requirements Power and Earth 18 to 12 AWG wires for 24 VDC system power and Earth ground for electical box (ground per local code) Mounting Information Trim Dimensions 4 1/2" H x 1113/16" W(114 mm x 300 mm) Assembly Depth 1 5/16" (33 mm), 1 1/2" at terminal block location (38 mm) Standard Trim Finish Steel, painted beige 4603-9111, Optional Trim Brushed aluminum (ordered separately) Trim Hardware Supplied with both slotted and tamper resistant screws Boxes for Flush Mounting (supplied by others) Masonry boxes Six-gang box, 2 1/2" (64 mm) deep minimum RACO # 960, 2 1/2" deep or RACO # 965, 3 1/2" (89 mm) deep or equal Single an boxes g gang Six, single gang boxes, 3 1/2" (89 mm) deep minimum, RACO # 600 or equal Box selection note Conduit entrance is box dependent, refer to additional mounting information on page 4 and Installation Instructions 574-188 2975-9217, Surface Mount Box Option* (ordered separately) Dimensions 12W x 45/8" H x 1 3/4" D (305mm x 117mm x 44mm) Finish I Painted steel, ivory finish * Reference Wiremold box number V5748-6. Up to 6 annunciator modules total, 4606-9101 or 4605 series, 24 point I/O modules Communications Single twisted, shielded pair, 18 AWG_-- Simplex Time Recorder Co. 3 S4606-0001-3 6/00 Mounting Information Flush Mount Ganged Boxes: Use 6-gang box, 3 1/2" (89 mm) mm. depth, RACO #590 using knockouts 2 1/2" from front, or RACO #600 using side knockouts or rear cable clamps, or equal (supplied by others) Ti3E t3tTf El1Tf tJtT iEifl Flush Mount Masonry Box: Use 6-gang box, RACO #960, 2 1/2" deep (64 mm) using top or bottom knockouts, or RACO #965,3 1/2" (89 mm) deep, using knockouts 2 1/2" from front, or equal (supplied by others) Surface Mount Box: t - ° ° 0 ° 0 ° (ordered separately)I (—'I Trim plate - 0 0 Terminal block access at flsbmk.rear of enclosure, this side Annunciator Assembly NOTE: Enclosure extension into box is 10" W x 2 5/8" H x 1 5/16" D, 1 1/2" deep at terminal block access, offset to left (254 mm x 67 mm x 33 mm, 38 mm), select conduit entry accordingly. I Wiring Reference Interconnection Wiring: Communications require a single 18 AWG twisted, shielded pair. Power requires two, 18 to 12 AWG wires for 24 VDC system power, plus Earth Ground to each electrical box. IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIL Refer to Installation Instructions 574-188 for additional wiring specifications 1 4606-9101 LCD Annunciators IIIIIIIIIIIIIIIIIIItIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIDhIIF 4010 Fire Alarm Control Panel .Sinip/e.r and the Simplex io'a are ret,'i'aered iraden,arkc u/Si,np/es 7/tue Recorder Co./ (/' and al/Icr cauniries. 111irentold is a irade,,,a,'k nfl/ic /Vire,uald ( nlupali) S4606-0001-3 6/00 Sirii lex Westminster, Massachusetts 01441-0001 USA visit us on the world wide web at www.simplexnet.com At specifications and other information shown were current as of printing and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0026:0179 Page 1 of 1 CATEGORY: 7120--ANNUNCIATORS LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern©tycoint.com DESIGN: Model *4603-9101 annunciator. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, *reference to the installation instructions, *intended installation environment: Indoor Dry, *use of product: Annunciator and UL label. APPROVAL: Listed as an annunciator for use with the following control units: Model 4100 (CSFM Listing No. 7165-0026:160, and 7165-0026:251) or Model 4020-8001 (CSFM Listing No. 7165-0026:178). NOTE: Not suitable for use with Model 4100 fire alarm control unit when the control unit is configured for proprietary receiving service. *Recerl 10-17-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing shou,-nbrbe used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation nstructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 201i2 / Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division !iSimplex TrueA!arm® Analog Sensing UL, ULC Listed; FM, CSFM, TrueAlarm Analog Sensors - Photoelectric, and NYC, MEA Approved* Ionization, and Heat; Compatible Bases and Accessories I ku I (4. TrueAlarm' analog sensing provides digital transmission of analog sensor values via MAPNET ll or lDNetTM, two-wire communications** Fire alarm control panel provides: Individual sensitivity selection for each sensor Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allowing accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check that verifies sensor integrity Automatic environmental compensation Display of sensitivity directly in percent per foot Multi-stage alarm operation Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors: Seven levels of sensitivity from 0.2% to 3.7% Heat sensors: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Ionization smoke sensors*: Three levels of sensitivity; 0.5%, 0.9% and 1.3% For use with Simplex: 4010, 4020, 4100, and 4120 Series control panels Universal Transponders and 2120 TrueAlarm CDTs equipped for MAPNET II operation Magnetic test feature Functional and architecturally styled chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Optional accessories include remote LED alarm indicator and output relays UL listed to Standard 268 These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. It is subject Is re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Refer to page 4 for ULC listing status. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. 4098-9714 lrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement that is digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the pane!. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. lrueAlarm analog sensors and MAPNET II and IDNet ccimunicahoss are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,552,765; 5,552,763; 4,796,025; DES. 377,460. S4098-0019-8 12/01 TrueAlarm Sensor Bases and Accessories Base mounted address selection: Address remains with its programmed location Accessible from front (dipswitch under sensor) Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design Magnetically operated functional test Mounts on standard outlet box Fi.i i1f'] 4098-9792, Standard sensor base 4098-9789, Sensor base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (unsupervised) 4098-9791, Sensor base with supervised relay driver output (not compatible with 2120 CDT): Relay operation is programmable and can be manually operated from control panel Use with remote mount 2098-9737 relay Also includes wired connections for remote LED alarm indicator or 4098-9822 relay Fi- i1.] !T 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A 0a 28 VDC; non-power limited rating of 3 A 0a 120 VAC (requires external 24 VDC coil power) 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @1 28 VDC; non-power limited rating of 1/2 A 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm & Indicator: Mounts on single cane box ALARM (shown in illustration to right) 0 9 Simplex Dscri ntic TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionization, or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. ivuounung rcererence Electrical Box Requirements: (boxes are by others) Without jJ: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With reIa: 4" octagonal or 4" square, 1-1/2" deep. with 1-1/2" extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference-..,,,, LO C' _ 1-1/2" (38 mm) minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (64 mm) maximum recess -------------------------------------------------- 2098-9737 Relay (mounts in 4098-9822 Relay (mounts base electrical box or remotely) in base electrical box) Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 cubic inches) (64mmX38mmX254mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. ------------------------------------------------ 6-3/8" (162 mm) 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and 4" square flush box H 4-7/8" (124 mm) 15/16' I (24 mm) 0 TrueAlarm Bases 4098-9789, -9791, & -9792 S4098-0019-8 12/01 TrueAlarm Sensors Iiit*i Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Listed to UL Standard 521 for 60 ft (18.3 m) spacing for 135° F (57.2° C) alarm, and 40 ft (12.2 m) spacing for 155° F (68° C) alarm Smoke Sensors: Photoelectric or ionization technology sensing 360° smoke entry for optimum response TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1°C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° Q. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to 1-IVAC system problems. (Refer to specific panels for availability.) 4-7/8 (124 mm) I ULED status indicator 2-3/8 (60 mm) TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. A built-in screen keeps insects from entering the smoke chamber. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 4-7/8" (124 mm) T LED status indicator 2-1/8" (54 mm) n p III) j r-17Tr7 4098-9714 Photoelectric Sensor with Base isi.t;m raE.] ii riTiIp]iD] TrueAlarm Ionization sensors use a single radioactive source with an outer sampling ionization chamber and an inner reference ionization chamber to provide stable operation under fluctuations in environmental conditions such as temperature and humidity. Smoke and invisible combustion gases can freely penetrate the outer chamber. With both chambers ionized by a small radioactive source [Am 241 (Americium)], a very small current flows in the circuit. The presence of particles of combustion will cause a change in the voltage ratio between chambers. This difference is measured by the electronics in the sensor base and digitally transmitted back to the control panel for processing. Three levels of sensitivity are available for each ionization sensor: 0.5, 0.9, and 1.3% per foot of smoke obscuration. 4-7/8' (124 mm) P1 J LED status indicator 2-1/8" - nl) (54 mm) 4098-9733 Heat Sensor with Base 4098-9717 Ionization Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. öJi IE*14.J 1 { E1iiIi Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide. For detailed application information, refer to 4098 Detectors, Sensors, and Bases Application Manual (5 74-709). S4098-0019-8 12/01 I ITti iw1 I-fiflflT1 7T rrM1T rti' WI TrueAlarm Sensor Bases Model Description Compatibility Mounting Requirements 4098-9792 (C) Standard Sensor Base, no options - Sensors 4098-9714, -9733, & -9717 4" octagonal or 4" square box,1-1/2" mm. depth, with 30-ring; or single gang box, 2" mm. depth Sensor Base with connections for Sensors 4098-9714, -9733, & -9717 4098-9789 (C) Remote LED Alarm Indicator or Unsupervised Relay 4 octagonal or 4 square box with 3" 0-ring, 2098-9808 remote LED alarm indicator or 4098-9822 relay Box depth requirements depend Sensor Base with connections for Sensors 4098-9714, -9733, & -9717 4098-9791 (Ct Supervised Remote Relay and on total wire count and wire size, refer to accessories list below for reference. 2098-9737 remote relay (supervised) remotealarm indicator or connections for Remote Alarm Indicator or Unsupervised Relay relay TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 (C) Photoelectric Smoke Sensor 4098-9717 (C) Ionization Smoke Sensor Bases 4098-9792, 4098-9789, and 4098-9791 Refer to base requirements 4098-9733 (C) Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Comoatibrhtv Mountina Reauirempnts Remote Mounting requires 4" octagonal or 2098-9737 Supervised Relay, mounts remote For use with 4098-9791 base 4" square box, 1-1/2" minimum depth or in base electrical box Base Mounting requires 4" octagonal box, 2-1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Bases 4098-9789 and 4098-9791 Single gang box, 1-1/2" minimum depth Relay, tracks base LED status 4" octagonal box, 2-1/8" deep with 1-1/2" 4098-9822 (C) (unsupervised, mounts only in base extension ring electrical box) Required for surface or semi-flush 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 mounted 4" square box without 3" 0-ring, ani for surface mounted 4" octagonal box i-eter to puolication 4uvd vetectors, sensors, anci bases /4PPlICtl0fl Manual(b/4-NU) tor additional Intormation. ULU listed model numbers are designated by (C) and require a "C" suffix such as 4098-9794C. T [.1 i General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet, auto-select, 24-40 VDC w/data, 400 tA typical, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG UL Listed Temperature Range 32" to 100° F (0" to 38" C) Operating with 4098-9717 or 4098 -9733 Temperature Range with 4098-9714 32" to 122° F (0" to 50° C) 15" to 122° F (-9° to 50° C) Humidity Range 10 to 95% RH Smoke Sensor 4098-9714, Photoelectric Sensor Ambient Ratings 4098-9717, Ionization Sensor Air velocity is 0-2000 ft/mm (0-610 rn/mm) Air velocity is 0-100 ft/min (0-30 rn/mm); Altitude is up to 8000 ft (2.4 km) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 tA, from 24 VDC supply Alarm Current with 2098-9737 Relay 1 28 mA, from 24 VDC supply 4098-9822 Unsupervised Relay Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current I Supplied from communications Alarm Current 13 mA from separate 24 VDC supply lyco, Simplex, the Simplex logo, 77i,eAlann, /vlAPNii 1/, and IDNet are trademarks 0/ l)co International Services AG or Its it//i/tales in the U.S. and or oilier countries NI/UI 72 is 0 i'eg,.ilered trademark if the Ncnwnal Fire ]'rolecnon Asiociatiot, (NFPA). Sirr1pIex Westminster, Massachusetts 01441-0001 USA www.simplexnet.com S4098-0019-8 12/01 /17 200/ Simplex Dote Recorder Co. /17/54 77'G-(JS (ci i)co company). All rights reserred. A/I speci/icaltons and other rn/am-ma/ton shown mrere curreni as nfdoctmtent revision dale rind are subject to chan/1'e nil/tout no/ice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: SimplexlOo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4098-9789,-9789E, 9789TSP, -978911P, -9791, -9791E, -9791TSP, 9791TTP,-9792, -9792E, -9792TSP, 979211P, -9793, -9793E, -9793TSP, -9793TTP, -9794, -9794TSP, -9794TTP, -9795,-9795TSP, -9795TTP, -9796, -9796T5P, -9796TTP; *GsA40989792 *9793 *..9795 and *..9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Bases are intended for use with the following units: Models 4098-9714 and *GSA4098.9714 series photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:231); and Models 4098-9733 and *GsA4098.9733 heat detector (CSFM Listing No. 7270-0026:216). Models 4098-9795, -9795TSP, -9795TTP, -9796, -9796T5P, -9796T1P; *GSA40989795 and *9796 are only intended for use with Models 4098-9754 or *GsA4098..9754 photoelectric smoke detector *(CSFM Listing No.7272-0026:218). Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, -9794TSP, -97941TP, -9795, -9795TSP, -9795TTP; and *GSA40989795 employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. NOTE: *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4098-9714, -9714TSP, -971411P, -9754 -975415P, -9754TTP; *GsA40989714 and *9754 analog photoelectric type smoke detectors. Units are intended for use with smoke detector bases Models 4098-9789 9789TSP, -9789TTP, -9791, -9791T5P, -9791TTP, -9792, -97921SP, 9792T1P, -9793, 9793TSP, -9793T1P, -9794, -9794TSP,-97941TP; *GsA40989792 and *..9793 (CSFM Listing No. 7300-0026:217). Models 4098-9714, -971415P and -97141TP are listed for use with Models 4098-9750-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755, -9755T5P and -9755TTP duct detector units (CSFM Listing No. 3240-0026:241). Models 4098-9754, -9754TSP, -9754TTP; *GsA40989754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed Models 4100, 4010, 4020, 4120 and *4008 series fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division i®SimpIex Multi-Application Peripherals UL, UL C, CSFM Listed; FM Approved; lDNetTM and MAPNET H® Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (lAMs) IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from JAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use with following Simplex control panels: Model Series 4008, 4010, and 4100U fire alarm control panels for IDNet communications Model Series 4100!4100U, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 MWE 4090-9001 Supervised [AM (shown approximately 3/4 size) 4090-9051 Supervised lAM (shown approximately 3/4 size) I'i4f. i 17. MR, Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. * These products have been approved by the California Stale Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for ** IDNet and MAPNET II addressable communications are protected under U.S Patent use - City of New York Department of Buildings - MEA35-93E. Additional listings may be Nos 4,796,025; 5,966,002; and 6,034,601 applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4090-0001-8 2/2006 L.IiiiIrTh Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). ['iii tM-6 i 471U For use with IDNet communications only, these lAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterflow switch monitoring can be determined and communicated by a single addressable point. lAM Product Selection Model Description 4090-9001 Supervised lAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 1 Supervised IAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws; galvanized steel 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. I Description 4081 -9004 733-886 6.8 kQ, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 kf2, 1/2 W 4081-9005 733-984 1.8 kI, 1/2W Use for current limited monitoring applications Specifications Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per ]AM Input Requirements Normally open, dry contacts Wire Connections 4090-9001 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2 Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9151 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from lAM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 1 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 4090-9001 4090-9051 1-9/16" W 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) 1-9/16" W 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-8 2/2006 Mounting Information 4090-9001 IDNet Field wiring shown supervised lAM for reference - 4-1/4" (108 mm) LED viewing port Single gang electrical box 2-1/2' (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate Light pipe for LED viewing (114 mm) CD _________ 2-1/2" (64 mm) 4090-9806, Trim plate for semi-flush mounted box 2-13/16" _ (72 mm) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-8 2/2006 4090-9051 Mounting Information Address setting is at rear of housing 4090-9051 Encapsulated Supervised lAM as~ Single gang electrical box 2-1/2 (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) Teco. Simplex. the Simpler logo. MAPA'ETI/. and ID/Vet are trademarks of Tvco Intet national Services AG or its affiliates in the U.S. and/or other countries. -mplex . Tyco Safety Products Westminster Westminster, MA 01441-0001 USA S4090-0001-8 2/2006 www.tycosafetyproducts-usa-wm.com 02006 Tvco Sajett Ptoth,cts Westminster. All iigl its reset ted. All specifications and otlter ,nfattnanott s/totin were current as ofdocument ret/sian date a,td ate suject to change tiithottt notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL Fe- FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattem©tycoint.com DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106TSP, and-9106T1P Class "A" ZAM Initiating Module; 4090-9101, -9101TSP, and -9I01TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: "Rece 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division £LSimplex UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* IFk'i*i Individually addressable manual fire alarm stations with: Power and data supplied via IDNet or MAPNET II addressable communications using a single wire pair Operation that complies with ADA requirements The NO GRIP Single Action Station and Retrofit Kit are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate Pull lever that protrudes when alarmed Break-rod supplied (use is optional) Models are available with single or double action (breakglass or push) operation UL listed to Standard 38 Compatible with the following Simplex® control panels: Model Series 4100ES, 4100U, 40IOES, 4010, 4008, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Compact construction: Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes I llltT1 The Simplex addressable manual station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (JAM) constantly monitors status and communicates changes to the connected control panel via IDNet or MAPNET II communications wiring. * Refer to page 2 for specific model listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code, See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet or MAPNET II Communicating Devices Addressable Manual Stations 4099-9001 4099-9020 4099-9805 Single action NO GRIP NO GRIP Single action Retrofit kit OP KEY ED ERAT ONLY Lf 4099-9002 4099-9003 With 2099-9828 Breakglass Push Institutional Cover kit Dn ratic Activation of the 4099-9001 single action manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Single Action NO GRIP Station 4099-9020. For applications such as California Building Code, Title 24, which requires "Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist" the model 4099-9020 station provides a more easily operated pull lever compared to standard stations. Retrofit of existing stations is available using the 4099-9805 Retrofit kit. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break- rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. S4099-0001-8 11/2011 Addressable Manual Stations, Red Housinq with White Letters and White Pull Lever Model 4099-9001 .escriptlon T Single action, English Housing FIRE ALARM Pull Lever_,.,Listings PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9001C8 Single action, Bilingual English and French FEU FIRE TIREZ PULL ULC, FM 4099-9001 CF Single action, French ALARME FEU ABAISSEZ 4099-9002 Double action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9003 Double action, Push operation, English 4099-9020 1 Single action NO GRIP operation, English I FIRE ALARM I PULL DOWN I UL, ULC, FM, CSFM Accessories Model 2975-9178 Description Surface mount steel box, red Refer to page 3 for dimensions Cast aluminum surface mount box, red 2975-9022 2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 Surface trim plate for Wiremold box V5744-2, red 2099-9814 2099-9819 Flush mount adapter kit, black Refer to page 4 for details Flush mount adapter kit, beige 2099-9820 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 4099-9805 Retrofit Kit for field conversion of a single action station to a NO GRIP station: refer to Installation Instructions 579-1007 for details TTUrk.] jl7r;1I Power and Communications IDNet or MAPNET II communications, 1 address per station Address Means DIP switch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 3-3/4" W x 1" D (127 mm x 95 mm x 25 mm) Single Gang Box Mount 4" Square Box Mount Single gang box, 2-1/2" deep 4" (102 mm) square box, 2-1/8" (54 mm) minimum (64 mm), RACO #500 or equal depth, RACO #231 or equal (supplied by others) cjTh (supplied by others) \\ p Mount flush or with 1/16" (2 mm) maximum extension -H..-- ______ Square box Gl olil RECESS 4" DO NOT , with Hcover plate L 0 Station [ALARM] side view or equal (supplied by others) - - - -) - Single gang cover plate, 3/4" tDOWN (19 mm) extension, RACO #77 Single gang box outline Wall surface Semi-Flush Mount Side View [Simplex / 2 S4099-0001-8 11/2011 Addressable Manual Stations Surface Mounting Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 2975-9178 Box 5-3/16" H 4" W x 2-3/16" D (132 mm 102 mm x56 mm) (ordered separately) Knockouts located top and bottom 2975-9022 Cast Box 5" H x 3-7/8' W x 2-3/16" 0 (127 mm x 98 mm x 56 mm) (ordered separately) I II 0 1!] PULL DOWN Access for 3/4" threaded 5- conduit located top and bottom (127 mm) _L L ra Simplex) 1(25.4mm) 3-3/4" (95 mm) 4099 Series Addressable Manual Station Iil1TiMTrrnttt n;. ri 'it-il Pifli I IPt1TI ii iiar. Refer to NFPA 72, the National Fire Alarm and Signaling Code, and all 11/4" applicable local codes for complete Field wiring (32 mm) Simplex 2975-9178 box requirements for manual stations. The (shown for reference) (shown for reference) following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed Address setting under _....L -y h—n in the protected area such that they resealable label (accessible are unobstructed and readily with cover open) accessible. 2-5/8 / (67 mm) Mounting shall be with the I operable part not less than 3-1/2 ft Station cover / I (1.1 m) and not more than 4-1/2 ft hinges open for I (1.37 in) above floor level. installation access 1. At least one station shall be "- Switch wiring provided on each floor. Additional (prewired) stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0001-8 11/2011 Addressable Manual Station, Additional Mounting Information For retrofit and new installations, additional compatible mounting boxes VC and the required adapter plates 2099-9814 Surface trim for Wiremold box are shown in the illustration to 5-1/8 H x 5W the right. (130 mm x 127 mm) 4099-9001 IDNet addressable station 2099-9813 Semi-flush trim for 2 gang switch box, 6" H x 4-1/2" W -i (152 mm x 114 mm) Wiremold C:IDI receptacle box H I model V5744-2 (supplied by others) GD Two gang switch box, each 3" H x 2"W x 2-3/4" D (76 mm x 51 mm x 70 mm) (supplied by others) 0 Erfror7mm.i rin ir1TrnrnTI rn Flush mount adapter kit 2099-9819, Black 2099-9820, Beige Box must be recessed into wall 1" to 1-1/8" (25.4mm to 29 mm) 1 Q 8' (203 mm) Hole cutout must be a 0 :. ()(j!i DOWN of 6" H by 5W 6" (152 _______ 1 . -- (152mmby127mm) mm) 0 " .. - - - - 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum Wall depth (by others) (121 mm) ________ surface Front View Side View TYCO. SIMPLEX, and the product names listed in this material are ,,tarks and/or registered marks. Unat,t/to,'i:ed use is strict! v pm'ohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark of/lie Gene,'a/ Electric Co. Wiremold is a trademark of the Wim'e,nold Company. I;.Si MPIEX Tyco Fire Protection Products" Westminster, MA 01441-0001 • USA S4099-0001-8 11/2011 www.simplexgrinnell.com 0 201I Tyco Fire P,'otectio,t Pm-or/acts. Al/tights t-esert'ed, Al/ specifications and outer information shown itete cut 'rent OS of documemtt revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: SimplexlOO Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models* 4090-9001, -900ITSP, -9001 TTP, and -9051 Supervised IAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106TSP, and-9106TTP Class 'A" ZAM Initiating Module; 4090-9101, -9101TSP, and -9101TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: "Recert. 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Simplex TrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSyncTM Operation AudibleNisible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable I1(Ii1*I Audible/visible (NV) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount: Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Operation requires connection to a compatible SmartSync operation NAC or to SmartSync Control Module (SCM) 4905-9938 Wall mount ANs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional UL/ULC listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex (R) 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs* Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Regulated circuit design ensures consistent flash output and provides controlled inrush current Listed to UL 1971 and ULC S526 Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) Listed to UL 464 and ULC S525 Wall and Ceiling Mount A/Vs psrrintir Multi-Candela TrueAlert ANs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. 7Y1 rni'i- rrn During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Refer to page 2 for listing status of wire guards. Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Simplex multi-candela SmartSync two-wire horn/strobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6,201 789; 6,954,137; 7,005,971; and 7,006,003. S4906-0002-5 9/2009 Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). U'IY IPT1 TIT1 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. I SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." F11iT4s1T1II.i,i 4006, 4008, 4100U, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination I JTT rrri-n ri -, horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color FIRE Lettering Description 4906-9127 Red White 4906-9129 Wail White Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9128 Ceiling White control control 4906-9130 White Red Wall Mount AN Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep Hx5Wx i-5/8"D 4905-9940 White surface mounted boxes depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Optional Sound Damper; package of 20; field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1-3/4" Diameter (44.5 mm) NOTE: After Sound Damper installation, measure sound level to ensure with 0.31" (8 mm) sound opening comoliance with aoolicable code recuirements SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description 4905-9994 Red cover with white "FIRE" lettering 4905-9995 White cover with red "FIRE" letterina Wire Guards and Ceiling Mount AN Adapter Model Description 49059961* Wall mount red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes 4905-9927" 1 1 Red Wire Guard for mounting to flush mounted electrical box 4905-9928" Ceiling Red Adapter Plate, required to mount guard to surface Mount mounted electrical box 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4905-9916 Red 1-1/2" deep surface mounted boxes Dimensions 5-1/8" H x 5" W x 1-1/2" 0 (130 mm x 127 mm x 38 mm) Dimensions 6-1/16" H x 6-1/16" W x 3-1/8" D (154 mm x 154 mm x 79 mm) 8-1/2"x6-1/8" x3" (216 mm x 156 mm x 76 mm) 9" x 7" (229 mm x 178 mm) 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) * UL listed by Space Age Electronics Inc. S4906-0002-5 9/2009 2 Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others LTh LTh çTh 0 0 Optional 4905-9838 Sound Damper, field attached to attenuate sound 5 to 6 dBA Wiring access hole Wiring terminals for SmartSync operation Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; factory setting is 15 cd AN Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 DC; see Note 1 below Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Model Type Wall Mount Ceiling Mount Horn Output Sound Type (see Note 2) Ratings Steady Coded Steady Coded (see Note 2 for Reverberant Chamber Test, polar dispersion per UL 464 @ 10 ft (-3 m) 86 dBA 82 dBA 87 dBA 83 dBA reference) Anechoic Chamber Test per 88 dBA 94 dBA 90 dBA 98 dBA Wall Mount Housing Dimensions (with lens) 5-1/8" H x 5W x 2-3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC at other voltages .24 VDC 67 mA 103 mA 196 mA 253 mA 50 mA 77 mA 147 mA 190 mA Ceiling Mount Housing Dimensions (with lens) 4-3/4 L' x 6-7/8" W x 2-5/8" D (121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 76 mA 117 mA 222 mA 284 mA 57 mA 88 mA 167 mA 213 mA NOTES: "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Polar dispersion per ULC S525 testing = -3 dBA at +1-40° off-axis; -6 dBA at +1- 50° off-axis. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) ffllrTIrTh z rrn ii1iiiUIT9 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly Electrical above bottom outline of compatible J'box 7 NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor L --- ___j I Removable cover Strobe Intensity (tool required) viewing slot 3 S4906-0002-5 9/2009 Ceiling Mount AN and Guard Installation Reference Ceiling reference, 4" (102 mm) square box, surface mounted box /" 1-1/2" (38 mm) minimum depth - Ceiling reference, - - flush mounted box --L~g Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are ('located behind the housing Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side -. 1111~I1130111 Nall 11=1= Optional 4905-9927 Red Wire Guard En d View View ------------------------------------ Strobe intensity viewing slot te Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 Cd -------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt 45 Box Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for 4" (102 mm) square box profile, 1-1/2" reference (38 mm) deep Optional 4905-9961 Wire Guard AN Eel 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, 0 4905-9961 Optional Wire Guard 1-1/2" deep: 4905-9937, Red; (shown here for reference only, 4905-9940, White (conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco is ci registered trademark of Tyco Inte,'nat,onal Services Gmbl-i vinci is used under license. Simplex. the Simplex logo. IDNet. T,'ueAle,'t, and Sma,'tSync are t,'ode,narks of Tyco inte,'nanonal Ltd. and its affiliates and are used nude,' license. AIFPA 72 and National Fire Ala,',,, Code are ,,'ade,na,'hs of the National Fire Protection Association (NFPA) -mplex Tyco Safety Products Westminster Westminster, MA 0144 1-0001 USA S4906-0002-5 9/2009 a www. tycosafetyproducts-usa-wm. corn © 2009 Tvco Safety Products Westminster. All rights rese,'red, All specifications and other informationnauo, sho,,n it ere current as ofclocianent P elision date and are subject to change ,,'itho,,t notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0317 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexlo0 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4906-9127, 4906-9129 wall mount and Models 4906-9128 and 4906-9130 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation Instruction Manual for details. NOTE: 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division License Number: 802591 Extract Date: 10/06/2010 SIMPLEX GRINNELL L P Business ATTN: LICENSING DEPT Information: P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number: (818) 247-1199 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2011 License Status: This license is current and active. All information below should be reviewed. DESCRIPTION Classifications: C10 ELECTRICAL C16 FIRE PROTECTION CONTRACTOR CONTRACTOR'S BOND This license filed Contractor's Bond number 81880913 in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2007 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL Bonding: 1. This license filed Bond of Qualifying Individual number 81880915 for RONALD GILBERT MAYLE in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2007 BQI's Bonding History 2. This license filed Bond of Qualifying Individual number 82199925 for TIMOTHY PAUL ROSTEN in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 05/27/2010 This license has workers compensation insurance with the NATIONAL UNION FIRE INSURANCE COMPANY OF PITTSBURGH, PA Workers' Policy Number: W0026149513 Compensation: Effective Date: 10/01/2010 Expire Date: 10/01/2011 Workers Compensation History Miscellaneous Information: 10/28/2005 ASB CERTIFICATION REMOVED SimplexGrinnell BE SAFE. A Tyco International Company SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www. sirnolexcirinnell. corn SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: 8:00AM TO 1 7:00PM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. 9/29/2009 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XXXXXXXXX NFPA Record of Completion Name of Protected Property Plaza Camino ReaIRobinsonsIMay Shell' Address r2525El Camino Real, Carlsbad CA- 92OO8_. Rep. of Protected Property (name/phone) Authority Having Jurisdiction Carlsbad Fire Department Greg Ryan Address I Phone Number 760- Type(s) of System or Service: X NFPA 72, Chapter 3 - Local if alarm is transmitted to location(s) off premise, list where received: Simplex Central Station NIA NFPA 72, Chapter 3 - Emergency Voice /Alarm Service: Quantity of voice/alarm channels Single: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in the system: CX\D uu CT) Multiple: NIA NFPA 72, Chapter 4 - Auxiliary Indicate type of connection: Local Energy, Shunt, Parallel Telephone Location and telephone number for receipt of signals: N/A NFPA 72, Chapter 4- Remote Station Alarm: Supervisory: NIA NFPA 72, Chapter 4- Proprietary If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving alarm: Indicate how alarm is retransmitted: N/A NFPA 72, Chapter 4 - Central Station: The prime contractor: Central Station Location: Means of transmission of signals from the protected premise to the central station: Mculloh Multiplex One-Way Radio Digital Alarm Communicator Two-Way Radio Others Means of transmission of alarms to the public fire service communications center: N/A N/A System Location: Organization Name / Phone Representative Name I Phone Installer SimplexGrinnell Bob Ciereck 858-633-9100 Supplier Simplex Grinnell Lane Smith 858-633-9100 Service Organization SimplexGrinnell Brian Piokin 858-633-9100 Page 1 of 1 NFPA Record of Completion Location of (As-Built) Drawings: Plaza Camino Real - Security Office Location of Owners Manuals: Same Location of Test Reports: Unknown A contract, dated N/A , for test and inspection in accordance with NFPA standard(s) No(s), dated , is in effect. Record of System Installation (Fill out after installation is complete and wiring checked for opens,shorts,ground faults and improper branching but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below,was inspected by SimplexGrinnell on , includes the devices shown below and has been in service since x NFPA 72, Chapters 1 3 4 5 6 7 (Circle all that apply) x NFPA 70, National Electric Code ,Article 760 x Manufacturer's Instructions Other ( Specify) Signed: - Date: Organization: SimplexGrinnell 3. Record of System Operation All operational features and functions of this system were tested by SimplexGrinnell Date: and found to be operating properly in accordance with requirements of: X NFPA 72, Chapters 1 3 4 5 6 7 (Circle all that apply) X NFPA 70, National Electric Code ,Article 760 X Manufacturer's Instructions Other ( Specify) Signed: Date: Organization: SimplexGrinnell 4. Alarm Initiating Devices and circuits (Use blanks to indicate quantity of devices.) Manual I Manual Stations x Noncoded,Activating Transmitters Coded Combination Manual Fire Alarm and Guard's Tour Coded Stations. Automatic Coverage: Complete Partial X I Smoke Detectors Ion X Photo 0 Duct Detectors Ion X Photo 0 Heat Detectors FT RR X FT/RR RC 2 Sprinkler Waterfiow Switches Transmitters X Noncoded,Activating Coded 0 Other(list): 5. Supervisory Signal Initiating Devises and Circuits (Use blanks to indicate quantity of devices.) Guards Tour N/A Coded Stations N/A Noncoded Stations Activating Transmitters N/A Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations Note: Combination devices recorded under 4(b) and 5(a). Page 1 of I NFPA Record of Completion Sprinkler System 5 Coded Valve Supervisory Signaling Attachments NIA Valve Supervisory Switches Activating - NIA Building Temperature Points NIA Site Water Temperature Points NIA Site Water Supply Level Points Electric Fire Pump: N/A Fire Pump Power N/A Fire Pump Running N/A Phase Reversal Engine Driven Fire Pump: N/A Selector in Auto Position I) N/A Engine or Control Panel Trouble N/A Fire Pump Running Engine Driven Generator: N/A Selector in Auto Position I) N/A Control Panel Trouble N/A Transfer Switches N/A Engine Running Other Supervisory Function(s) (Specify) NONE Transmitters 4 Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: 0 Bells Inch 0 Speakers 0 Horns 0 Chimes 0 Other: I Visual Signals Type: Xenon I with audible 0 Local Annunciator 0 w/o audible Signaling Line Circuits: Quantity and Style (See NFPA 72, Table 3-6) of signaling line circuits connected to the system. Quantity: I Style: Y System Power Supplies Primary (Main): Nominal Voltage: I20VAC Current Rating: Overcurrent Protection: Type: Circuit Breaker Current Rating: Location: Secondary (Standby): X Storage Batteries Amp-Hour Rating 10 amp hour Calculated capacity to drive system, in hours: X 24 60 NIA Engine driven generator dedicated to fire alarm system: N/A Location of fuel storage: Emergency/Standby System used as backup to Primary Power Supply, instead of useing a secondary Power supply: N/A Emergency System described in NFPA 70, Article 700 N/A Legally Required Standby System described in NFPA 70, Article 701 N/A Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 Page 1 of I NFPA Record of Completion 9. System Software Operating System Software Revision Level(s) Application Software Revision Level(s): Revision Completed by: Tom Wilkins SimplexGrinnell (name) - ,. (firm) (sig4ed - f®r Central Station or Alarm Service Company (title) (date) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): NOT IN CONTRACT System deviations from the referenced NFPA standard(s) are: NONE (signed) for Central Station or Alarm Service Company (title) (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) (date) Page 1 of 1