HomeMy WebLinkAbout2525 EL CAMINO REAL; ; AS090087; Permit12/5/24, 11:03 AM AS090087 Permit Data City of Carlsbad Sprinkler Permit 2525 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 1563020900 Lot #: 0 Permit No: AS090087 Status: ISSUED Applied 7/29/2009 Approved: 7/29/2009 Reference No.: Issued: 7/29/2009 PC #: Inspector: Project Title: 1-MOBILE T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: BRADSHAW ENGINEERING CORP 8645 ARGENT ST SANTEE CA 619-448-4300 Owner: PLAZA CAMINO REAL C/O WESTFIELD PROPERTY TAX DEPT P0 BOX 130940, DEPT WFLD CARLSBAD, CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 ASo9ôô Bulletin 121 Rev.I Model G4 Concealed Automatic Sprinkler (0 The Concealer® A Concealed Sprinkler With %" (13mm) or 1%" (38mm) Adjustment Features Push-on/Thread-off cover plate assembly attachment with 1/2" (13mm) adjustment. Does not require clips or springs. 11/2" (38mm) Total adjustment provided by adjustable inlet versions. Adjustable inlet version available with either 1" NPT ale or female threads eliminating costly reducing coupling. Smooth aesthetic ceiling profile. Available in white or other color painted or brass, chrome, or black plated finishes. Ordinary and intermediate temperature ratings. Multiple orifices for design flexibility. Approvals & Listings Underwriters Laboratories Inc. (UL) Underwriters Laboratories of Canada. (ULC) N.Y.C. BS&A No. 587-75-SA. Note: Approvals are for light and ordinary hazard, except for small orifice sprinklers which are limited to light hazard occupancies. The cup and skirt are fabricated from plated steel and are intended for interior non corrosive applications. U.S. Patent No. 4,880,063. Application The Reliable Model G4 - concealer® is the most versatile concealed sprinkler available. It provides the best form of fire pro- tection while offering an attractive appearance and ½" (13mm) of cover adjustment for ease of instal- lation. The adjustable 1" NPT inlet versions have 1)/2" (38mm) of total adjustment and also eliminates the need for a reducing cou- pling. The small diameter Push-on/Thread-off cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an automatic sprinkler system. N.. The concealer® is designed for use where aesthetic ap- pearance is important. Offices, hospitals, motels and res- taurants are but a few of the applications where it can be used. It is available in different orifice sizes allowing the de- signer to optimize system performance, thereby achieving a most efficient installation. The concealer® can eliminate the need for precise cutting of drop nipples. The Push-on/Thread-off cover plate assem- bly can be adjusted without tools so it mates accurately with the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Product Description The Reliable Model G4 concealer® uses the proven Model G fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The Push-on/Thread-off cover plate and sprinkler cup assem- blies are held tight by a flexible tooth engagement to the threaded cup. This threaded engagement provides ½" (13mm) of cover adjustment. The flat cover plate is attached to the skirt using an ordinary temperature classification sol- der. This results in a strong cover plate assembly with an or- dinary temperature rating, and an intermediate temperature sprinkler which can be installed in 150°F (66°C) environ- ments. When the ceiling temperature rises, the solder hold- ing the cover plate to the skirt melts, the flat cover plate released thus exposing the sprinkler inside to the rising am- bient temperature. The subsequent fusing of the sprinkler element opens the waterway and causes the deflector to drop into position to distribute the discharging water. Any secure engagement of the threads between the cover plate and cup will assure that the drop—down deflector is properly located below the ceil- ing when a sprinkler operates. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Installation Do not install The Concealer® in ceilings which have positive pressure in the space in the space above. After a 2/ inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model G4 Wrench. The wrench has drive tangs which insert into cup slots. When installing a sprin- kler the wrench is first positioned into the sprinkler/cup assembly until the wrench tangs engage drive slots in the top of the cup (there are two sets of mating drive slots in the cup). The sprinkler is then tightened into the pipe fithng. When inserting or removing the wrench from the sprinkler/cup assembly care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OFTHE SPRINKLER/CUP ASSEMBLY. The adjustable inlet versions are similar to the standard Model G4 except that an addition 1" (25mm) of adjustment is provided by means of a telescoping inlet section that threads in or out of a stationary coupling reducer (either 1 male or 1 female) as shown in Hg. 2 or Fig. 3. These sprinklers must be installed before the ceiling is in place, by wrenching on only the coupling reducer Temperature Ratings Classification Sprinkler Cover Plate Max. Ambient Temp. Ordinary 135°F/57°c 135°F/57°C 100°F/38°C Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Ordinary 165°F/74°C 165°F/74°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C Installation Data hex flats. After the ceiling has been installed with holes for the sprinkler, each telescoping inlet section is to be adjusted with the G4 Wrench. Install the push-on/thread-off cover plate assembly over the sprinkler by holding and pressing it straight up into the cup. Final adjustment of each cover assembly is made by hand turning it clockwise until it is tight against the ceiling. Maintenance The Model G4 Concealer® should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick re- placement of damaged or operated sprinklers. Prior to installa- tion, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Cover Plate Finishes (1) Sprinkler Model Temperature Rating Nominal Orifice Flat Cover Plate Finish Inlet Type White Note: Unless otherwise specitied, the 165°F (74°C) sprinkler will be provided with the 165°F (74°C) cover. Standard Finishes Bronze Chrome Plated Special Application Finishes Black Plated Bright Brass Off White Black Paint Nominal Sprinkler Sprinkler Total Nominal ._KYactoL. Identification Thread Approvals Inlet Adjustment Orifice US Metric Number (SIN Non-Adjustable X"(13mm) )"(15rrrn) 5.6 80 X"NFr(R½) 1,2,3 R2115 Non-Adjustable ," (13mm) 7X6"(llmm) 4.2 El) X" NPT(RY2) 1,2,3 R2113 Non-Adjustable )"(13mm) %"(lCtrrn) 28 40 ,"NPT(R½) 12,3 R2111 Adjustable 1,"(38mm) )°(15rrfli) 5.6 80 1"NPT Male crFemale 1,2,3 R2118 Adjustable 1X"(38mm) %6"(11—)6"(llm) 4.2 El) 1"NPT Mae erFen-ale 1,2,3 R2113 Adjustable 1X"(38mm) 3/8"(1CtTT1) 2.8 40 1"NFT Male erFoniata 12,3 R2112 111 Other colors and finishes are available. Consult factory for details Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Installation Wrench Model G4 Sprinkler Wrench Fig. 1 - )'" (Ry2) NPT Non— Adjustable Inlet Fig. 2- 1" NPT Male-Adjustable Inlet Fig. 3- 1" NPT Female—Adjustable Inlet The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by — - The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Office (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/02 PIN 9999970014