HomeMy WebLinkAbout2525 EL CAMINO REAL; 227; AS070050; Permit12/5/24, 10:17 AM AS070050 Permit Data
City of Carlsbad
Sprinkler Permit
2525 EL CAM INO
Job Address:
REAL
Permit Type: SPRINK
Parcel No: 1563020900
Lot #: 0
Reference No.:
Permit No: AS070050
Status: ISSUED
Applied 3/6/2007
Approved: 3/6/2007
Issued: 3/6/2007
PC #: Inspector:
Project Title: ZUMIEZ, STE. 227 Ti. FIRE SPRINKLER PLAN CHECK &
INSPECTION
Applicant:
BRADSHAW ENGINEERING CORP
8645 ARGENT ST
SANTEE CA
619-448-4300
Owner:
PLAZA CAM INO REAL
C/O WESTFIELD CORP INC
11601 WILSHIRE BLVD
LOS ANGELES CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
L 124 0 124 0
about:blank 1/1
Aso_-oo 50
December 15, 2006 Sprinkler 20a
HORIZON® MIRAGE®
STANDARD AND QUICK
RESPONSE CONCEALED
PEN DENT SPRINKLERS
The Viking Corporation, 210 N industrial Park Road, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com
DESCRIPTION
Viking Horizon® Mirage® Standard and Quick Response Concealed Pendent
Sprinklers are small solder link and lever spray sprinklers designed for installation on
concealed pipe systems where the appearance of a smooth ceiling is desired.
Horizon® Mirage® Standard and Quick Response Concealed Sprinklers are hidden
from view by low-profile cover plates installed flush to the ceiling. The cover plates
are available with various decorative finishes to meet design requirements.
The two-piece design of the unit allows installation and testing of the sprinklers prior
to installation of the cover plates. After the system has been tested and the ceiling
finish applied, the "push-on", "thread-off design of the cover plate assemblies allows
easy installation of the cover plates with up to %" (12.7 mm) adjustment available.
The "thread-off' feature is designed to prevent unwanted disengagement of the cover
assemblies. This feature also permits temporary removal of ceiling panels without
taking the sprinkler system out of service or removing the sprinkler.
LISTINGS AND APPROVALS
cULus Listed: Category VNlV
FM Approved: Class 2015
NYC Approved: MEA 89-92-E, Volume 27 and 28
NOTE: International approval certificates are available upon request.
Refer to the Approval Chart on page 20d and Design Criteria on page 20e for cULus Listing and FM Approval requirements that
must be followed.
TECHNICAL DATA
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar) Viking Technical Data may be found on
Maximum Working Pressure: Sprinklers VK405 and VK454 are rated The Viking Corporation's Web site at
for use with water working pressures ranging from the minimum http:I/www.vikingcorp.com.
7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. The Web site may include a more recent
High-pressure (HP) sprinklers can be identified by locating "250" edition of this Technical Data Page.
stamped on the sprinkler body. Sprinkler VK404 is rated to a maxi-
mum 175 psi (12 bar) wwp.
Factory tested pneumatically to 95 psi (6.55 bar)
Spring: U.S.A. Patent No. 4,570720
Thread size: 1/2" (15 mm) NPT
Nominal K-Factor: 5.6 U.S. (80.6 metrict)
tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
Available Cover Plate Vertical Adjustment: %" (12.7 mm) +1- 1/4" (6.4 mm)
Material Standards:
Sprinkler Body: Brass UNS-C84400
Body Cap: Brass UNS-C26000
Deflector: Copper UNS-C19500
Deflector Pins: Stainless Steel UNS-S30300
Button: UNS-C23000 H55-H80
Screw: Brass UNS-C36000
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape
Fusible Link Assemblytt: Nickel Alloy and Eutectic Solder
ttThe fusible link of the Quick Response Concealed Sprinkler is marked with a purple stripe or dot for identification purposes only.
Fusible Link Levers: Stainless Steel UNS-S31600
Lever Bar: Copper Alloy UNS-C72500
Form No. F_021993 Replaces page 20a-c, dated May 19, 2006
(reformatted).
Sprinkler 20b December 15, 2006
HORIZON® MIRAGE®
's1IF(1I*1G STANDARD AND QUICK
RESPONSE CONCEALED
PENDENT SPRINKLERS
The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com
Cover Assembly Materials:
Cover Plate Assembly: Brass UNS-C26000 or UNS-C26800
Spring: Nickel Alloy
Solder: Eutectic
Ordering Information: (Also refer to the current Viking price list.)
Viking Horizon5 Mirage5 Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be or-
dered separately:
Sprinklers: Base Part No. 09782A, 09783A, or 12292
Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number:
Temperature Suffix (°F/°C): 165°/74° = C, 220°/i 04° = F
For example, sprinkler VK404 with a 165 °F/74 °C temperature rating = 09783AC.
Cover Plate Assembly:
Base Part No. 11225 with a 2-3/4" (69.8 mm) diameter, 135 °F/57 °C rated
Base Part No. 09804 with a 2-3/4" (69.8 mm) diameter, 165 °F/74 °C rated
Base Part No. 11697 with a 3-5/16" (84.1 mm) diameter, 135 °F/57 °C or 165 °F/74 °C rated
Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the
appropriate suffix for the cover temperature rating to the base part number:
Finish Suffix for Covers 09804 and 11697: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A,
Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/SW1004, Painted Ivory = M-/SW1634, Painted Black =
M-/SWi 007
Finish Suffix for Cover 11225: Polished Chrome = F
Temperature Suffix (°F/°C): 1350/57° = A, i 65°I74° = C
For example, cover 09804 with a Polished Chrome finish and a 165 °F/74 °C temperature rating = 09804FC.
Available Finishes And Temperature Ratings:
Refer to Table 1
Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.)
Sprinkler Wrenches*:
Heavy Duty Part Number 08336W/B (available since 1983), or
Light Duty Part Number 10366W1B** (available since 1998)
*Requires a 1/2' ratchet (not available from Viking).
**Ideal for sprinkler cabinets.
Sprinkler Cabinet: Part No. 01731A, Capacity: six (6) sprinklers (available since 1971)
INSTALLATION
Refer to appropriate NFPA Installation Standards.
OPERATION
During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches.
Continued heating of the sprinkler causes the heat-sensitive fusible link to disengage, releasing the deflector and sealing assembly.
Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern to extinguish or control the fire.
INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
AVAILABILITY
Viking concealed sprinklers are available through a network of domestic and international distributors. See The Viking Corporation
web site for the closest distributor or contact The Viking Corporation.
GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
December 15, 2006 Sprinkler 20c
HORIZON® MIRAGE®
STANDARD AND QUICK .JII(1r4IG RESPONSE CONCEALED
PENDENT SPRINKLERS
The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com
TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES
Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of Cover cover Plate
Classification Temperature Rating' Ceiling Temperature2 Assembly (Required) Base Pait Number'
Ordinary 165 °F(74°C) 100°F(38°C)
135°F (57 °C) 11225 or 11697
165°F (74 °C) 09804 or 11697
Intermediate 220 °F (104 °C) 150°F (65 °C)
135°F(57°C) 11697
165°F (74 °C) 09804 or 11697
Cover Plate Finishes: For Covers 09804 and 11697: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed
Brass, Brushed Copper, Painted White, Painted Ivory, and Painted Black. For Cover 11225: Polished Chrome
Footnotes
The sprinkler temperature rating is stamped on the sprinkler body.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having
Jurisdiction. Refer to specific installation standards.
Base part number is shown. For complete part number, refer to Viking's current price list schedule.
Concealed
Sprinkler
rLJ:4RTl Body
Protective
Sprinkler
Shell
Concealed Sprinkler
Wrench** Part
No. 08336W/B
A 1/2 ratchet
is required (not
available through Viking).
1___ l i
Figure 1: Sprinkler Installation and Correct Use of Wrenches
pill! _
J= =I J =1 LJ
Sprinkler VK405 Sprinkler VK404
or VK454
Figure 2: Concealed Sprinklers and Cover Assemblies
Sprinkler 20d December 15, 2006
HORIZON® MIRAGE®
\I 1K] F1G'i I:II[.1.Lw STANDARD AND QUICK
RESPONSE CONCEALED
PENDENT SPRINKLERS
The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com
Approval Chart
Horizon Mirage Standard and Quick Response T
Concealed Pendent Sprinklers l*G rFs4 AV KY
Sprinkler NPT Thread Nominal Maximum Overall Length Listings and Approvals45
Base Part SIN Size K-Factor Water Working (Sprinkler Body) (Refer also to Design Criteria on page 20e.)
Number' Pressure Inch mm u.s. metric2 Inches mm cULus6 FM7 NYC
Standard Response Applications
09782A VK405 1/2" 15 5.6 80.6 250 psi (17.2 bar)3 2-11132" 59.5 AW2,AY1, BY -- AW2,AY1, BY 18
09783A VK404 1/2" 15 56 80.6 175 psi (l2bar) 2-11/32" 595 -- AX1,AY1,AZ1 AXI,AYI,AZ19
Quick Response Applications
09783A VK404 1/2" 15 56 80.6 175 psi (12 bar) 2-11/32" 595 -- AW2,AX1,AYI,
AYI,BX1,BY1
12292 VK454 1/2" 15 5.6 80.6 250 psi (17.2 ba r)3 2-11/32" 59.5 --
AW2,AX1,AY1,
Ay1,Bx1,By1
Cover Plate Assembly Temp. Ratings10 - Finishes of the Cover Plate Assembly
Sprinkler Temperature Ratings W- 135 °F(57 °C) cover 11225 1 - Polished Chrome, Brushed Chrome, Bright Brass,
A - 165°F (74 °C) X - 135 °F (57 °C) cover 11697 (large diameter) Antique Brass, Brushed Brass, Brushed Copper,
B - 220 F (104 C) Y - 165F (74 ° °C' cover 09804 /
Painted" White (No. 1004)12, Painted" Ivory (No.
Z - 165 F (74 C) cover 11697 (large diameter) 1634)12, or Painted" Black (No. 1007)I2
2 - Polished Chrome
Footnotes
Part number shown is the base part number. For complete part number, refer to current Viking price list schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3The Water Working Pressure rating is stamped on the sprinkler body.
' This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad-
ditional approvals.
5Listings and approvals are for hazard occupancies up to and including Ordinary Hazard, Group II.
Listed by Underwriter's Laboratories for use in the U.S. and Canada.
FM Approval is limited to wet systems and preaction systems qualifying as wet systems
Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 28.
Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 27.
'°The 135 °F cover has an orange label. The 165 °F cover has a white label.
"Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors.
12Sherwin-Wi Ilia ms5 Color AnswersTM Interior Color Number.
December 15, 2006 Sprinkler 20e
HORIZON® MIRAGE®
Si IIIf1G STANDARD AND QUICK
RESPONSE CONCEALED
PENDENT SPRINKLERS
The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com
DESIGN CRITERIA
(Also icier to the Approval Chad on page 20d
cULus Listing Requirements:
Horizon® Mirage® Standard and Quick Response Concealed Pendent Sprinklers are cULus Listed for installation in accordance with the latest edition
of NFPA 13 for standard coverage pendent spray sprinklers as indicated below:
For hazard occupancies up to and including Ordinary Hazard, Group II.
Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m).
Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13.
Minimum distance from walls is 4 in. (102 mm).
Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured
perpendicular to the wall.
The sprinkler installation and obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed.
NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only.
FM Aøoroval Requirements: Horizon® Mirage® Concealed Pendent Sprinkler VK404 is FM Approved as a standard response standard spray sprinkler
as indicated in the Approval Chart. For use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for hazard occupancies
up to and including Ordinary Hazard, Group II. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical
Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum
water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below
the ceiling.
NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria.
NOTE: Covers 09804 or 11697 must be used for all Factory Mutual Approved installations. Previous Model B-i Cover Plate Assembly Part Number
08310 may still be used for cULus installations. The correct Horizon® Mirage® Sprinkler can be verified by checking the fusible link for the following
identification scheme:
Standard Response: No stripe or dot.
Quick Response: Purple stripe or dot.
EC or QREC: Yellow stripe or dot.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page
SRI-2 or QRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed
in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global,
LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordi-
nances, and standards, whenever applicable.
Note' Upon sprinkLer activation, the deflector descends to
approximateLy 13/16' (20.6 min) beLow the sprinkLer body.
2" (508 mm)
diameter opening 1/2"
required, or 2-5/8" ç_ __ (15 mm)
It
I -
using large
(66.7 mm) when t ' t I NPT
'Cover 11697
F1 i 2-3/4" (69.8 mm)
or 3-5/16"
I (84.1 mm) for
large Cover 11697
Figure 3: Sprinkler Dimensions and Cover Installation
THIS PAGE
INTENTIONALLY
I q 42 9:1 kil ki 121,
i
Form No. F_021993 Replaces page 20a-c, dated May 19, 2006
(reformatted).
BRADSHAW ENGINEERING CORPORATION
FIRE PROTECTION ENGINEERS & CONTRACTORS
CA LICENSE # 383330 LICENSE CLASS C16 C34 HIC
8645 ARGENT ST, SANTEE, CA 92071-4179
TELEPHONE: 619-448-4300 FAX: 619-448-0535
TRANSMITTAL
TO:
ATTENTION: PLAN REVIEW DATE: MARCH 1, 2007 JOB NO: L3238
REGARDING: FIRE SPRINKLERS PLANS
CARLSBAD FIRE PREVENTION
1635 FARADAY AVENUE
CARLSBAD, CA 92008
(760) 602-4665
JOB SITE:
ZUMIEZ SPACE #227
PLAZA CAMIMO REAL
2525 EL CAMINO REAL
CARLSBAD, CA 92008
WE ARE SENDING YOU THE FOLLOWING:
COPIES DATE DESCRIPTION
I COPY OF CARLSBAD FIRE DEPARTMENT PERMIT APPLICATION
BUILDING PERMIT # CB 070051
I CHECK FOR $124.00
3 PRINTS OF FIRE SPRINKLER TI
I SET SPRINKLER HEAD CUT SHEETS
IF YOU HAVE ANY QUESTIONS, PLEASE FEEL FREE TO CALL ME,
THANK YOU,
PATSY GOFKOWSKt