Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 227; AS070050; Permit12/5/24, 10:17 AM AS070050 Permit Data City of Carlsbad Sprinkler Permit 2525 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 1563020900 Lot #: 0 Reference No.: Permit No: AS070050 Status: ISSUED Applied 3/6/2007 Approved: 3/6/2007 Issued: 3/6/2007 PC #: Inspector: Project Title: ZUMIEZ, STE. 227 Ti. FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: BRADSHAW ENGINEERING CORP 8645 ARGENT ST SANTEE CA 619-448-4300 Owner: PLAZA CAM INO REAL C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) L 124 0 124 0 about:blank 1/1 Aso_-oo 50 December 15, 2006 Sprinkler 20a HORIZON® MIRAGE® STANDARD AND QUICK RESPONSE CONCEALED PEN DENT SPRINKLERS The Viking Corporation, 210 N industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Horizon® Mirage® Standard and Quick Response Concealed Pendent Sprinklers are small solder link and lever spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. Horizon® Mirage® Standard and Quick Response Concealed Sprinklers are hidden from view by low-profile cover plates installed flush to the ceiling. The cover plates are available with various decorative finishes to meet design requirements. The two-piece design of the unit allows installation and testing of the sprinklers prior to installation of the cover plates. After the system has been tested and the ceiling finish applied, the "push-on", "thread-off design of the cover plate assemblies allows easy installation of the cover plates with up to %" (12.7 mm) adjustment available. The "thread-off' feature is designed to prevent unwanted disengagement of the cover assemblies. This feature also permits temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approved: Class 2015 NYC Approved: MEA 89-92-E, Volume 27 and 28 NOTE: International approval certificates are available upon request. Refer to the Approval Chart on page 20d and Design Criteria on page 20e for cULus Listing and FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Viking Technical Data may be found on Maximum Working Pressure: Sprinklers VK405 and VK454 are rated The Viking Corporation's Web site at for use with water working pressures ranging from the minimum http:I/www.vikingcorp.com. 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. The Web site may include a more recent High-pressure (HP) sprinklers can be identified by locating "250" edition of this Technical Data Page. stamped on the sprinkler body. Sprinkler VK404 is rated to a maxi- mum 175 psi (12 bar) wwp. Factory tested pneumatically to 95 psi (6.55 bar) Spring: U.S.A. Patent No. 4,570720 Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Available Cover Plate Vertical Adjustment: %" (12.7 mm) +1- 1/4" (6.4 mm) Material Standards: Sprinkler Body: Brass UNS-C84400 Body Cap: Brass UNS-C26000 Deflector: Copper UNS-C19500 Deflector Pins: Stainless Steel UNS-S30300 Button: UNS-C23000 H55-H80 Screw: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Fusible Link Assemblytt: Nickel Alloy and Eutectic Solder ttThe fusible link of the Quick Response Concealed Sprinkler is marked with a purple stripe or dot for identification purposes only. Fusible Link Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Form No. F_021993 Replaces page 20a-c, dated May 19, 2006 (reformatted). Sprinkler 20b December 15, 2006 HORIZON® MIRAGE® 's1IF(1I*1G STANDARD AND QUICK RESPONSE CONCEALED PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Cover Assembly Materials: Cover Plate Assembly: Brass UNS-C26000 or UNS-C26800 Spring: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Horizon5 Mirage5 Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be or- dered separately: Sprinklers: Base Part No. 09782A, 09783A, or 12292 Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 165°/74° = C, 220°/i 04° = F For example, sprinkler VK404 with a 165 °F/74 °C temperature rating = 09783AC. Cover Plate Assembly: Base Part No. 11225 with a 2-3/4" (69.8 mm) diameter, 135 °F/57 °C rated Base Part No. 09804 with a 2-3/4" (69.8 mm) diameter, 165 °F/74 °C rated Base Part No. 11697 with a 3-5/16" (84.1 mm) diameter, 135 °F/57 °C or 165 °F/74 °C rated Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix for Covers 09804 and 11697: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/SW1004, Painted Ivory = M-/SW1634, Painted Black = M-/SWi 007 Finish Suffix for Cover 11225: Polished Chrome = F Temperature Suffix (°F/°C): 1350/57° = A, i 65°I74° = C For example, cover 09804 with a Polished Chrome finish and a 165 °F/74 °C temperature rating = 09804FC. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches*: Heavy Duty Part Number 08336W/B (available since 1983), or Light Duty Part Number 10366W1B** (available since 1998) *Requires a 1/2' ratchet (not available from Viking). **Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: six (6) sprinklers (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the sprinkler causes the heat-sensitive fusible link to disengage, releasing the deflector and sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking concealed sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. December 15, 2006 Sprinkler 20c HORIZON® MIRAGE® STANDARD AND QUICK .JII(1r4IG RESPONSE CONCEALED PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of Cover cover Plate Classification Temperature Rating' Ceiling Temperature2 Assembly (Required) Base Pait Number' Ordinary 165 °F(74°C) 100°F(38°C) 135°F (57 °C) 11225 or 11697 165°F (74 °C) 09804 or 11697 Intermediate 220 °F (104 °C) 150°F (65 °C) 135°F(57°C) 11697 165°F (74 °C) 09804 or 11697 Cover Plate Finishes: For Covers 09804 and 11697: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, and Painted Black. For Cover 11225: Polished Chrome Footnotes The sprinkler temperature rating is stamped on the sprinkler body. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Base part number is shown. For complete part number, refer to Viking's current price list schedule. Concealed Sprinkler rLJ:4RTl Body Protective Sprinkler Shell Concealed Sprinkler Wrench** Part No. 08336W/B A 1/2 ratchet is required (not available through Viking). 1___ l i Figure 1: Sprinkler Installation and Correct Use of Wrenches pill! _ J= =I J =1 LJ Sprinkler VK405 Sprinkler VK404 or VK454 Figure 2: Concealed Sprinklers and Cover Assemblies Sprinkler 20d December 15, 2006 HORIZON® MIRAGE® \I 1K] F1G'i I:II[.1.Lw STANDARD AND QUICK RESPONSE CONCEALED PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Approval Chart Horizon Mirage Standard and Quick Response T Concealed Pendent Sprinklers l*G rFs4 AV KY Sprinkler NPT Thread Nominal Maximum Overall Length Listings and Approvals45 Base Part SIN Size K-Factor Water Working (Sprinkler Body) (Refer also to Design Criteria on page 20e.) Number' Pressure Inch mm u.s. metric2 Inches mm cULus6 FM7 NYC Standard Response Applications 09782A VK405 1/2" 15 5.6 80.6 250 psi (17.2 bar)3 2-11132" 59.5 AW2,AY1, BY -- AW2,AY1, BY 18 09783A VK404 1/2" 15 56 80.6 175 psi (l2bar) 2-11/32" 595 -- AX1,AY1,AZ1 AXI,AYI,AZ19 Quick Response Applications 09783A VK404 1/2" 15 56 80.6 175 psi (12 bar) 2-11/32" 595 -- AW2,AX1,AYI, AYI,BX1,BY1 12292 VK454 1/2" 15 5.6 80.6 250 psi (17.2 ba r)3 2-11/32" 59.5 -- AW2,AX1,AY1, Ay1,Bx1,By1 Cover Plate Assembly Temp. Ratings10 - Finishes of the Cover Plate Assembly Sprinkler Temperature Ratings W- 135 °F(57 °C) cover 11225 1 - Polished Chrome, Brushed Chrome, Bright Brass, A - 165°F (74 °C) X - 135 °F (57 °C) cover 11697 (large diameter) Antique Brass, Brushed Brass, Brushed Copper, B - 220 F (104 C) Y - 165F (74 ° °C' cover 09804 / Painted" White (No. 1004)12, Painted" Ivory (No. Z - 165 F (74 C) cover 11697 (large diameter) 1634)12, or Painted" Black (No. 1007)I2 2 - Polished Chrome Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3The Water Working Pressure rating is stamped on the sprinkler body. ' This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. 5Listings and approvals are for hazard occupancies up to and including Ordinary Hazard, Group II. Listed by Underwriter's Laboratories for use in the U.S. and Canada. FM Approval is limited to wet systems and preaction systems qualifying as wet systems Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 28. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 27. '°The 135 °F cover has an orange label. The 165 °F cover has a white label. "Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. 12Sherwin-Wi Ilia ms5 Color AnswersTM Interior Color Number. December 15, 2006 Sprinkler 20e HORIZON® MIRAGE® Si IIIf1G STANDARD AND QUICK RESPONSE CONCEALED PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com DESIGN CRITERIA (Also icier to the Approval Chad on page 20d cULus Listing Requirements: Horizon® Mirage® Standard and Quick Response Concealed Pendent Sprinklers are cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below: For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. FM Aøoroval Requirements: Horizon® Mirage® Concealed Pendent Sprinkler VK404 is FM Approved as a standard response standard spray sprinkler as indicated in the Approval Chart. For use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for hazard occupancies up to and including Ordinary Hazard, Group II. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. NOTE: Covers 09804 or 11697 must be used for all Factory Mutual Approved installations. Previous Model B-i Cover Plate Assembly Part Number 08310 may still be used for cULus installations. The correct Horizon® Mirage® Sprinkler can be verified by checking the fusible link for the following identification scheme: Standard Response: No stripe or dot. Quick Response: Purple stripe or dot. EC or QREC: Yellow stripe or dot. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-2 or QRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordi- nances, and standards, whenever applicable. Note' Upon sprinkLer activation, the deflector descends to approximateLy 13/16' (20.6 min) beLow the sprinkLer body. 2" (508 mm) diameter opening 1/2" required, or 2-5/8" ç_ __ (15 mm) It I - using large (66.7 mm) when t ' t I NPT 'Cover 11697 F1 i 2-3/4" (69.8 mm) or 3-5/16" I (84.1 mm) for large Cover 11697 Figure 3: Sprinkler Dimensions and Cover Installation THIS PAGE INTENTIONALLY I q 42 9:1 kil ki 121, i Form No. F_021993 Replaces page 20a-c, dated May 19, 2006 (reformatted). BRADSHAW ENGINEERING CORPORATION FIRE PROTECTION ENGINEERS & CONTRACTORS CA LICENSE # 383330 LICENSE CLASS C16 C34 HIC 8645 ARGENT ST, SANTEE, CA 92071-4179 TELEPHONE: 619-448-4300 FAX: 619-448-0535 TRANSMITTAL TO: ATTENTION: PLAN REVIEW DATE: MARCH 1, 2007 JOB NO: L3238 REGARDING: FIRE SPRINKLERS PLANS CARLSBAD FIRE PREVENTION 1635 FARADAY AVENUE CARLSBAD, CA 92008 (760) 602-4665 JOB SITE: ZUMIEZ SPACE #227 PLAZA CAMIMO REAL 2525 EL CAMINO REAL CARLSBAD, CA 92008 WE ARE SENDING YOU THE FOLLOWING: COPIES DATE DESCRIPTION I COPY OF CARLSBAD FIRE DEPARTMENT PERMIT APPLICATION BUILDING PERMIT # CB 070051 I CHECK FOR $124.00 3 PRINTS OF FIRE SPRINKLER TI I SET SPRINKLER HEAD CUT SHEETS IF YOU HAVE ANY QUESTIONS, PLEASE FEEL FREE TO CALL ME, THANK YOU, PATSY GOFKOWSKt