Loading...
HomeMy WebLinkAbout5858 DRYDEN PL; ; AS160124; Permit12/5/24, 4:19 PM AS160124 Permit Data City of Carlsbad Sprinkler Permit Job Address: 5858 DRYDEN PL Permit Type: SPRINK Parcel No: 2120910600 Lot #: 0 Permit No: AS160124 Status: ISSUED Applied 5/10/2016 Approved: 5/27/2016 Reference No.: Issued: 5/27/2016 PC #: Inspector: Project Title: DRYDEN FLORAL CENTER TI TI OF EXISTING 6,000 SF OF SECOND FLOOR. INCLUDES NEW PARTITIONS CREATING NEW OFFICE SPACES. Applicant: PACIFIC FIRE SYSTEMS, INC. 13142 NELSON LANE POWAY, CA 858-722-9865 Owner: SUNROAD RESEARCH CENTER PARTNERS L P C/O SUNROAD ENTERPRISES 4445 EASTGATE MALL #400 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 483 0 483 0 about:blank 1/1 MATERIAL DATA SUBMITTAL DRYDEN FLORAL CENTER Tenant Improvement 5858 Dryden Place Carlsbad, CA 92008 ICrJ Pj0 FJPLE SYSTEMS, INC Pacific Fire Systems, Inc. 12316 Oak Knoll Rd. Suite B Poway, CA 92064 (858) 883-2333 Phone • (858) 883-2334 Fax AS 160124 5858 DRYDEN PL DynamThread 0 Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch4O with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. P QUO L <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Specificati onsI:WApprovals Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40fDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pc WI/Lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs;.Lg— ill 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 1056 11/4' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11/i 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2' 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 8.80 30 871 998 1037 16100 S. Lathrop. Harvey, IL 60426 Customer Service: ti/Co c: llied 11350 Norcom Rd.. Philadelphia, PA 19154 (800) 882-5543 a vital part of your world TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3 -3 SMITH - COOPER <@> INTERNATIONAL Ductile Iron Threaded Fittings C®US * ALL FITTINGS 1009/6 AIR TESTED * ASME/ANSI B16.3 * ISO 9001:2000 MANUFACTURER ASTM A536 Grade 65,45,12 USTEI) * LISTED/APPROVED AT 500 PSI * ASME/ ANSI B 1.201 APPRWED fliwbl., lrrni Rjill i.1il Too fliwf1e Irnn PpIndno Tpp Fkiir RT Figure 35BT - FHf - Size A I B I C Wqt 3/4 x 3/4 x I 1.45 1.45 1.37 0.68 1 x x 1-1/4 1.67 1.67 1.58 0.97 1x1x1-1/2 1.80 1.80 1.65 1.14 1-1l4xlx1-112 1.88 1.80 1.82 1.43 1-114 x 1-1/4 x 1-1/2 1.88 1.88 1.82 1.52 1-1/4x1-1/4x2 2.10 12.101 1.90 2.00 1-1/2x1-1/4x2 2.16 12.101 2.021 1.94 1-1/2x1-1/2x2 2.16 2.16 2.02 2.00 2 x 2 x 2-112 2.60 1 2.60 2 flneHle lrnn Hoy RMiwntv Cniin1iny Figure 35RC Size T Wgt LI . I x 1/2 1.69 0.40 1x314 169 0.38 1-1/4x314 2.06 0.53 2 x 1(not hex) 2.81 0.63 fltwH1 Trnn ('m £ Rp4ii,4no' ('rnl - Figure 35X Size A * A .". A W o B 1.56""1.50 0.97 1-1/4 1.75 1.75 1.59 -1/2 1.94 1.94 1.89 Figure 3M -- Size A B !. -1I4x 1 1.67 1.58 1.25 1-1 X1 T5 T -7.48 2x1 fliufilo. lrnri P111w Figure 35SP - Size - 'T Wf 1 i + 1/2 0.94 0.10 3/4 1.12 0.18 1 1.25 0.28 1-1/4 1.37 0.50 1-1/2 1.44 0.70 2 Size r -r -" 3J4x314x 1/2 120 1.201 1 0.46 1x1/2x1 1.50 1.36 1.50 0.70 1x3/4x3/4 1.38 1.31 1.45 0.68 I x3/4 xl 1.50 1.45 1.50 0.77 1xlx1/2 1.26 1.26 1.36 0.66 I x I x 3/4 i. 13 1.45 07 1-1/4x1/2x1-1/4 1.75 1.53 1.75 1.04 1-114x314x1-1/4 1.75 1.62 1.75 1.09 1-1/4x 1 x 11 1.34 1.26 1,53 0.81 1-1/4 x I x3/4 1.45 1.38 1.63 0.90 1-114x I x 1.581 1.50 1.69 1.03 -1/4x1x1-1/4 75 1.69 1.75 1.10 .i771..1/4x1/2 34 1.34 1.53 0.87 -114x1-114x314 ;-T-W .1. 0.96 -1/4 x1-114 x I 1.10 -112 .M i.Y x 1/2 x 1-114 T7 1-112 T. .! x 1/2 x 1-1/2 f.•1.94 1.42 1-1/2x3/4x1-1/4 1.94 1.66 1.88 1.42 1-1/2x314x1-1/2 1.94 1.75 1.94 1.47 1-1/2 x I x 1/2 1.4411.25 1.691 0.97 1-1/2 x x 3/4 1.50 1.44 1.761 1.14 1-1/2 x I x 1 9 ' i TöO 1.14 1-1/2x1 x1-1/4 1.82 1.67 1.88 1.47 1-112Th1-1r2 'i i 7W T T 1-1P2x1-1/4x112 141 1.34'-W T05 1-1/2x1-1/4x3/4 1.521 1.45 1.75 1.10 1-1/2 x 1-1/4 x 1 1.65 1.58 1.80 1 1.31 1-1/2x1-114x1-1/4 1.82 1.75 1.88 1 1.52 1-1/2Ix1-1/4x1-1/2 T 1.88 T94 T30 1-1/ x 1-1/2 x 1/2 TT 1.41 T 1'T 1-1/2 x1-1/2 x3/4 1.52 1.52 1.75 1.23 1-1/2x1-1/2x1 1.65 1.651 1.80 1.38 -1I2 x 1-1/2 x 1-1/4 1.82 1.82 1 1.88 TO xfx2 2.25 2.02 2.25 TTI x1-1/4x2 2.25 2.10 2.25 2.31 x' -1/2 x 1/2 1.49 1T1 T -1.501 x 3/4 - '.O -1-W TY TT xl-1/2x1 .73 1 1.65 2.02 1.65 x1-1/2 x1-1/4 1.901 1.82 2.10 2.03 x1-1/2x1-1/2 2.02 1.94 2.16 2.37 x 1-112 x 2 2.25 2.16 12.25 2.53 x2xl/2 1.49 1.49 1.88 1.50 x 2 x 3/4 - =6 T T*Y 1.7 x2x1 1 1.73 1.73 2.02 1.91 x2x1-1/4 . 1.90 1.90 2.10 2.05 2 x 2 x 1-1/2 TOY1 2.02 T9 SMITH - COOPER IN TERN AT ION AL Ductile Iron Threaded Fittings c ®us * ALL FITTINGS 1000/a AIR TESTED *ASME/ANSI B16.3 <0 > * ISO 9001:2000 MANUFACTURER * ASTM A536 Grade 65,45,12 USTED * LISTED/APPROVED AT 500 PSI * ASME/ ANSI B 1.20.1 fliwHlp Irnn Qfl° Plhnw Figure 35E Size I A I I - j t1 /_.1.13 0.24 3/4 321 0.40 1.50 0.64 -1141.75 095 -1/2 1.94 1.24 2.25 1.74 ntte4fla ii.rnl 0(1° Ui1..m, Figure 35RU Size ••A Y WT A* $ 3/4x1/2 1.22 1.20 0.33 1x1/2 1.36 1.26 0.44 I x3/4 1.45 .38 - 0.53 1-114x112 1 153 1.34 0.64 1-1/4 x 314 1.631 1.45 0.75 1-1/4 x 1 1.67 .58 0.77 1-1/2x1f2 175 1.52 - p. X 3/4 1.76 1-1/2x1 11.65 0.99 1-112x1-114 1.88 1. T'fl 2x1/2 1.97 1.60 1.35 2x3/4 1.97 1.60 1.39 2 x 1 2.02 1.73 1.58 2x1-1/4 2.10 1.90 1.62 2x1-1/2 2.16 2.02 .67 2-1/2 x 1-1/2 2.51 2.16 ;2.32 2-1/2x2 Tö Ductile Imrt Bra Sai IIrtinn Figure 35U Slze 'X Wgt 11 1/2 t1 4 ' i -i. 1 L 1 2.19 1.08 1-1/4 2.50 1.54 2.602 2.03 2 3.15 Thwtih' Trnn ('niinlinor Pigwe35CP Size A FJ A 4, 1/2 1.38 0.18 314 1.63 0.26 1 1,75 0.44 1-1/4 i 0.54 1-1/2 Til 0.71 2 2.62 1.15 2-1/2 flmH1. Trnvi ('in 35C Size A __ rf 'I' . + 1/2 0.87 0.15 3/4 097 022 1.16 0.33 1-1/4 1.28 0.54 1-1/2 1.33 0.68 2 11 .461 096 2-12 1 1.701T5 - - flut'+ilp Trnri How fliithrici Figure 35HB Size r WF x 1/2 1.06 0.22 x3/4 1.06 0.18 -1/4x1 1.19 0.31 -1/2 x 1 1.25 0.53 -112x1-1/4 1.25 035 x 1.38015 xl-1/4 1.38 x 1-1/2 . ö Ductile Iron 4O IIhnw Figure 35F Size 4 /2 0802 /4 098 033 1.13 0.48 -1/4 - 1.29 0.73 -1/2 44 093 Ductile Iron Beam Clam L \ -tip I Size I A IWgU 13/8 0.75I oi i MODEL V-723 SADDLE-LET (Small Mechanical Tee) -c The Model 723 Saddle-Let is the ideal outlet fitting for direct connections to sprinkler heads dip nipples and or gauges No need for welding lust cut or drill a hole at the desired outlet location. Position the Saddle-Let so that the locating collar fits within the - hole and secure with the U-bolt and nuts. The Saddle-Let comes with a standard black finish or as an option can be supplied elects zinc plated or painted orange. The Saddle- Let allows full bore flow and is pressure rated to 300 psi (20 bar). c®Us S; LISTED APPROVED Hole Dia 0 teiisionc-nmVm Take-Out Nominal Size +1.6, -0/+0.063, -O 1 Bolt Size Bolt Torque Wutglit 01m1115 mm/in A B C mm/in N to/Lb-Ft Kgo Lbs 32 X 15 30 53,0 890 56.0 35.0 3180 20-30 fbI 1.25x0.5 118 208 350 2.20 138 U-Bolt- 15-22 019 32 *20 30 53,0 89.0 56,0 35.0 3/8o 20-30 154 125 0075 118 208 350 220 138 U Bolt 15 22 159 32 025 30 56.0 89.0 56.0 38.0 3/8o 20-310 04 1.25*1 1.18 .2.20 3,50 . 2.20 1.50 U-Bolt 15-22 40 0 15 30 55.0 89.0 56.0 35.0 3/80 , 20-30 154 1.5*0.5 1,18 2.16 3.50.. 2.20 1.38.. U-Bolt 69 40020 30 55.0 89.0 56.0 390 3/80 20-30 154 15 *075 118 216 350 220 138 U Bolt 15 22 09 40* 25 30 58.0 89.0 56.0 38.0 3/80 20-30 04 15iti 118 228 350 220 150 U Bolt 15-22 6,9 50* 15 30 64.0 98.0 56.0 42.0 3/80 20-30 154 2*05 118 251 385 220 165 U Bolt 15-22 159 50*20 30 64.0 98.0 56.0 42.0 3/8o 20-30 154 2*0.75 1.18 . 2.51 3.85 120 1,65 U-8olt. . 1522 159 50*25 30 67.0 98.0 56.0 45.0 3/8o 20- 30 04 2*1 118 263 385 220 177 uBolt 15 22 159 65* 15 30 69.0 111.0 56.0 51,0 3/8o 20-30 154 25x05 118 271 437 220 2.W.US It 15-22 09 65 x 20 30 69.0 111.0 56.0 51.0 3/80 20-30 04 25 x 075 118 2.71. 437 2.20.200 U SoIl 15-22 09 65 * 25 30 72.0 111.0 56.0 54.0 3/80 20-30 155 25 * 1 118 283 437 220 213 U B It 15-22 II i. Mole Diameters listen are suggestea 0010 saw Diameters. 2. T: Take-out (Center of mis to end of pipe to be engaged) Trusted above all.TM 25 1 NAAJ SAMMYS FOR WOOD tot less than Wood Flooring ' ,ommn width No pie-drilling required Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs Manufactured in the USA, f .' 4'atah a video de'oOetiooat —gwww.itwbulldex.com a. #14 Black Nut Driver Part It 8113910 I #14 SW Red Nut Driver Part #8114910 114' 8002957 GST 1*0 14 x 1' 210 (7fl5'OSB) 800' 14x2 - 8 800 3T1 4x1 34p 38'800c 3ST2 4x2 8061 GOT 211-OS 1750 (Fr) 800 3ST25-383 112 2113 )F) 8011 GOT 00 2060 F 806C GST3-SS - 801:. GST2 8015925 GOT 3 .4 x 31' - - 25 125 25 125 370 25 125 850 - 25 125 850 25 125 'oo 5 125 00 25 125 125 - 125 25 125 a WWI I,*, 10 000oa.cruaor LS a. SPECIAL NUT DRIVER SYSTEM: The nut drive a were designed with a unique spin-off featre which provides a fast and safe installation each time. When the face of the driver comes into , contact with the material you are installing into, cntinue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Not lots than 2 nominal width (11/20) Lip tc 3-1/2 pipe; not less than 3 (2-1/2) nominal width 4 & 5 pipe IN I 0 7Fbor At f Minimum 21/20 from bottom for branch lines. Minimum 3 from bot- tom for main lines. Exception: This requirement shall not apply to 2 or No pre-drilling required. Quick to install using the Sammy Nut Driver with an iSV cordless drillldriver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Q U 1 1/4 8019957 S/1G I /8 8020957 SWG 8 , 8021957 SWG #14 SIN Red _38 Nut Dover Part #8114910 May require pre-d, mO. consult joist manufacturer. watch a video demc,,msftabon at www.itwbulldex.com Screw ,scriptions Ultimate Pullout (lbs) UL Test Box Case Load (lbs) Qty Qty 1/4 a 2' 1725 (Fir) 25 125 1/4x1 1 622 (Fir) /. 25 1- 114 x 2- 1725 (Fir) -- HL. 25 14x2 12° 3)8x2-1)Z 2245 1:4x 11 3 1884 r 125 Eliminates distortion of threaded rod. Accommodates up to 3 W x 12 pitch roof. Allows 17 deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. -14 Black Hilt Ddver Pa #8113910 2 May require pre-driliinç conceit joist manufacturer. #140H3 arqtr N;J 'er part #827j910 CL 82699 H GSli.ST2O F 550 45-25 12b 903 Dim. Lumber 8303957 SH-GST/CST 2.0 5/16 x 1-3/4 1406 @ 450 verficet 25 125 Dim. Lumber Component of State of California OSHPD Approved Seismic Restraints System FIG. 98 Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8' thru 7/8' hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Plannino and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD oroiects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number . L Fli Fig. 99 - All Thread Rod Cut to Length Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F WtJ100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 Size Range - Secures 3/8" thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92819 • PH: 951.737.5599 • FAX: 951.737,0330 CUSTOMER SERVICE • 800.786.5286 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2' thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8') in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. a,, Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 2/e 400 11 3/4 3/8 8mm or10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 3/e 2% 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 11/2 3/8 8mm or 10mm 3/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 4½ 600 27 3 3/8 10mm 5/8 4 600 29 31/2 3/8 10mm 7% 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 9517375599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com H November 16, 2010 Sprinkler 41 a MICROFAST® AND MicrofastHP® QUICK sI IIlrIG RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 9-92-E, Volume lö ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e104 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-C PD-40 170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41 d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pros- http:llwww.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 06662B and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Form No. F081296 Replaces page 41a-f, dated October 8, 2010. (Updated deflector material for PN 0672013.) Sprinkler 41 b November 16, 2010 MICROFAST® AND MicrofastHP® QUICK "iI II(I11G RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-EnIo = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°I57° = A, 155°I68 = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the 'Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Coated and/or Recessed Sprinklers: Part No. 12144W/B* (available since 2003) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. *A 1/2 ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The 'liking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flats Protective Sprinkler Cap 10896 (D Figure 1: Standard Sprinkler Wrench 10896W/B November 16, 2010 Sprinkler 41 c MICROFAST® AND MicrofastHP® QUICK \,J II(IISIG RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS flAND 1IlFINISHES Sprinkler Temperature ' Sprinkler Nominal Maximum Ambient Bulb u oar Classification Temperature Rating Ceilhg Temperature Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) tOO °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 'F (65 'C) Green High 286 'F (141 °C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approvng agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. I I ___..-_-,_ :1 - ---- Carefully slide the wrench sideways L7 around the protective cap ensuring engage— merit with the sprinkler *wA 1/2' ratchet is required wrench flats (not available from Viking). - Sprinkler Wrench 12144W/3** for InstallIng coated arid/or recessed pendert sprInkler's with protective caps. Sprinkler 41d November 16, 2010 MICROFAST® AND MicrofastHP® QUICK I II(IIs1G RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com ADDroval Chart 1 (UL) Microfast and MicrofastHP Quick Response Pendent Sprinklers A I X I Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No." NPT BSP U.S. metric? Inches mm cULus4 NYC5 VdS LPCB CE Standard Orifice 06662B I VK302 1/2" 115 mm 5.6 80.6 } 2-1/4" 1 58 1 AIX, BIY AiX, BIY A3 A3X, 133Y C3X, E3Y11 C3X, E3Y13 Large Orifice 06666B I VK352 1 3/4" 20 mm 1 8.0 1 115.2 1 2-3/8" 1 60 1 AiX, B1Y I AiX, B1Y I A3 I A3X I C311 -- 06765B I VK352 1/2" 1 15 mm 1 8.0 1 115.2 1 2-3/8" 1 60 1 AIX, BIY I AiX, B1Y I A3 -- -- -- Small Orifice' 06718B9 VK329 1/2" 15 mm 2.8 40.3 2-3/16' 56 AiX, B1Y AiX, B1Y -- -- -- -- 06720B9 VK331 1/2" 15 mm 42 57 2-1/4" 58 AiX, B1Y AiX, B1Y -- -- -- -- 06932B VK331 -- 10 mm 4.2 57 2-3/8" 60 -- -- A3 -- G212 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN - K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metri& Inches mm cULus4 NYC'- VdS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4' 58 AiX, B1Y AiX -- -- -- -- Maximum 250 PSI (17 bar) WWP Small Orifice' 1229010 VK342 1 1/2" 1 15 mm 2.8 1 40.3 I 2-3/16" 1 56 AiX, B1Y AiX -- -- -- I -- Approved Temperature Ratings A - 135 °F (57 °C), 155°F (68 °C), 175 °F (79 °C), 200 °F (93 °C), Approved Escutcheons and 286 °F (141 °C) Approved Finishes x - Standard surface-mounted escutcheon or B - 135°F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F 1 - Brass, Chrome-EnIoy, White the Viking Microfast Model F-i Adjustable Polyeste 7, Black Polyeste 7, Escutcheon C -155 °F(68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F and Black T eflon (141 °C) Y - Standard surface-mounted escutcheon or D - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F 2 - Brass and Chrome-Enloy the Viking Microfast Model F-i Adjustable (141 °C) 3 - Brass, Chrome-Enloy, White Escutcheon or recessed with the Viking E - 155 °F (68 °C), 175 °F (79 "C), and 200 °F (93 °C) Polyester7, and Black Polyester7 Micromatic® Model E-1 or E-2 Recessed F - 155 °F (68 °C), 175 °F (79 °C), and 286 °F (141 °C) Escutcheon G - 155 °F (68 °C) I Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 0 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. 10Ap9epted for use, City of New York Department of Buildings. MEA Number 89-92-E, Vol. 16. 11 .t Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 (f Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 1 13 0 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-108. November 16, 2010 Sprinkler 41e MICROFAST® AND A MicrofastHP® QUICK NIKJW*i RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA - UL Ar' ro10r :0 Apro.a CLrt 1 or oogo 11d cULus Listing Requirements: Microfast and MicrofastHP11 Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page Q11111-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16' (587 mm) minimum I 2-1/8' I 2-1/2' (63,5 rim) mOXUM (54 1/2' (15 mm) ______ •i:::::::::::i::;::::::: ______ NPT ______ iii 1-3/4' r~r 2-1/4' (445 rim) (381 mm) (58 rim) (5 mum (41 ) \IK ,I1/ M Pendent Sprinkler 06662B (VK302) Installed with a standard 1/8' surface- mounted escutcheon, Installed with a Microfast Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size 2-1/8' (54 mm) 2-5/16' (58.7 mm) Minimum (54 mm) 2-1/2' (635 mm) maximum (4, Mc Installed with a Micr-omatic Model E-1 Recessed Escutcheon \L ) ,1/ 1-1/8" (28,6 mm) (50,8 mm) \-J Minimum Maximum Installed with a thread on Model E-2 Recessed Escutcheon mm) Sprinkler 41f November 16, 2010 MICROFAST® AND MicrofastHP® QUICK "44,J I KJ RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2: (:FM) KEY Microfast Quick Rspons Pendent Sprinklers Maximum 175 PSI 12 bar) WWP Sprinkler Thread Size Nominal K-Factor 1 Overall Length FM Approvals3 SIN Base Part No.1 NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) StE ndard Orifice 06662B VK302 1/2" 115 mm 5.6 60.6 1 2-1/4" 58 A2X, B2Y Large Orifice 06666B I VK352 "" I 20 mm 8.0 115.2 1 2-3/8" I 60 AIX, B1Y Small Orifice' 06718B6 VK329 1/2" 1 15 mm 2.8 .0.3 2-5/16" I 56 AIX Approved Escutcheons Approved Temperature Ratings Approved Finishes X - Standard surface-mounted escutcheon or the Viking A- 135 OF (57 "C), 155 OF (68 "C), 175°F (79 "C), I- Brass and Chrome-Enloy® Microfast Model F-i Adjustable Escutcheon 200 OF (93 "C), and 286 OF (141 "C) 2-Brass,Chrome-Enloy®,White Polyester', Y - Standard surface-mounted escutcheon or the OF B - 135°F (57 "C), 155 OF (68 °C), 175 (79 "C), arid Black PoIester5 Viking Microfast Model F-i Adjustable Escutcheon OF "C) and 200 (93 or recessed with the Viking Micromatic5 Model E-1 or E-2 Recessed Escutcheon Footnotes Base part number is shown. For complete part number, refer to Viking's current prce schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of 3rint1ng. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (incuding Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. 6 The sprinkler orifice is bushed. DESIGN CRITERIA - FM Ao refer 1:ppm crrI2 FM ADDroval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approvad as quck resDonse Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines reating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. tSpnnklers VK302 and VK352 are also FM Approved as quick respoise Rack Storage standard spray pendent sprinklers. Refer to technical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page 0111-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated October 8, 2010. (Updated deflector material for PN 0672013.) July 12, 2012 Sprinkler 51 a MICROFAST® AND MicrofastHP® QUICK 'ij II(IF1G® RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHPO Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester and Polytetrafluoroethylene (PTFE) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in Approval Chart 1. (Note: FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV M Ann,nsrn,1 ')rvv) ,rsd )1fl T: •71 nflhl NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificates G4060054, G4060056, G4880046, G4930039, and G4980020 LPC Approved: Ref. No. 096e/03, TE30401, and TE30872 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, 0786-CPD-40171, and 0786-CPD-40278 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on pages 51c-d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 51e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi (0.5 The Viking Corporation's Web site at bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure http:/Iwww.vikinggroupinc.com. (HP) sprinklers can be identified by locating "250" stamped on the The Web site may include a more recent deflector. All other Part Nos. not mentioned above are rated to a maxi- edition of this Technical Data Page. mum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 "F (-55 "C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12978, 06766B, 07060, and 12281. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12978, 06764B, and 12281. Copper UNS-C19500 for Sprinklers 06665B, 07060, and 14817. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 067178, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Form No. F080488 Replaces page 51a-e, dated August 4, 2011. (Revised main image and VK300 - part number, removed brand name and replaced with PTFE) Sprinkler 51b July 12, 2012 MICROFAST® AND MicrofastHP® QUICK "4sj IKI FIG RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast' and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy' = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N Temperature Suffix (°F/"C): 135"/57° =A, 155"/68" = B, 175°/79" = D, 200"/93" = E, and 286"/141° = G For example, sprinkler VK300 with a 1/2" thread, Brass finish and a 155 °F/68 "C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfase and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. f:]I TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Ii Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 °F (57 "C) 100 "F (38 "C) Orange Ordinary 155 "F (68 "C) 100 "F (38 °C) Red Intermediate 175 "F (79 "C) 150 "F (65 "C) Yellow Intermediate 200 "F (93 "C) 150 °F (65 °C) Green High 286 "F (141 "C) 225 "F (107 "C) Blue Sprinkler Finishes: Brass, Chrome_Enloye, White Polyester, Black Polyester, and Black PTFE Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black PTFE Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and PTFE coatings. July 12, 2012 Sprinkler 51c MICROFAST® AND MicrofastHP® QUICK 41KJNG*:RESPONSE UPRIGHT AND VENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Approval Chart I (UL) KEY Microfast and McrofastHP Quick Response - A1X fpi - Upright and Conventional Sprinklers - -- - Maximum 175 PSI (12 bar) WWP Base Part SIN Thread Size Nominal K-Factor Overall Length Listin and Approvals3 (Refer also to Design gs Criteria on page 51d.) Number' I NP TT BSP U.S. I metric2 Inches mm cULus4 I NYC8 VdS LPCB I CE I Upright-Standard Orifice 12978 VK300 I 1/2 I 15 mm I 5.6 I 80.6 2-3/16 I 56 I Al See Footnote 7.1 -- 07060 VK345 -- 15 mm 5.6 I 80.6 2-3/16 I 56 -- I - A2 A2 B212 I B21 Conventional-Standard Orifice 06766B I VK31O I 1/2" 15 mm j 5.6 I 80.6 2-3/16 I 56 j A2 I A2 - I A2 8212 I B215 Upright-Large Orifice 06665B I VK350 i" 1 - 8.0 115.2 2-5/16 59 1 Al Al A2 I A2 B212 - 14817 VK350 - I 20 mm 8.0 115.2 2-5/16 59 Al Al A2 A2 8212 - 06764B [ VK350 1/2 j 15 mm 8.0 115.2 2-5/16 59 [ Al Al A2 -- 13 -- Conventional-Large Orifice __________ - 06768B VK354 3/4" ] 20 mm } 8.0 115.2 1 2-5/16 1 59 Al A2 .- [ A2 B212 -_ Upright-Small Orifice" 0671713111 VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Al - -- - -- 06719B11 VK327 1/2" 15 mm 4.2 57 2-3/16 56 Al Al - -- - C3,4 -- -- 06931 B11 VK327 - 10 mm 4.2 57 2-3/16 56 -- -- A2 -- Maximum 250 PSI (17 bar) WWP Upright-Standard Orifice Base Part SIN Thread Size ____________ Nominal K-Factor ______________ Overall Length _____________ Listings and Approvals' (Refer also to Design Criteria on page _______________ _____ _____ 51d.) Number' NPT I BSP U.S. I metric2 Inches I mm cULus4 I NYC9 VdS LPCB _____ CE 12281 VK315 1/2" 15 mm 5.6 80.6 2-3/16 56 Al T Al - -- - -- Upright-Small Orificele 1228611 I VK340 j 1/2" 15 mm 2.8 I 40.3 1 2-3/16 56 Al Al - I -- I - -- Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155 °F (68 °C), 175°F (79 °C), 200°F (93 °C), and - Brass, Chrome-Enloy , White Polyester' .6, Black Polyester56, 286 °F (141°C) and Black PTFE5 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - Brass, Chrome-Enloy5, White Polyester',', and Black C - 155 °F (68 °C) Polyester56 3 - Brass and ChromeEnloya Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. °cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. Meets New York City requirements, effective July 1, 2006. Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. lo Listings and Approvals limited to Light Hazard Occupandes where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. 72 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40278. 14 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 11 • MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. Sprinkler 51d July 12, 2012 MICROFAST® AND MicrofastHP® QUICK 1I FI Ir1G'i RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESIGN CRITERIA - UL rc:fr fo ..Appr u.in! Char 1 on .Oln) cULus Listing Requirements: Microfasr and MicrofastHP8 Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in Approval Chart I for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Protective Sprinkler Flat Wrench Cop Figure 1: Standard Sprinkler Wrench 10896W/B July 12, 2012 Sprinkler 51e MICROFAST® AND MicrofastHP® QUICK IIttttt1I II(II1G® RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart 2 (FM) Microfast Quick Response Upright Sprinklers AIX 4 r Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length J FM Approvals3 Number' SIN (Refer also to Design Criteria below.) NPT BSP U.S. j metric2 Inches j mm Standard Orifice 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A2 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 A2 Large Orifice 06665B VK350 3/4" - 8.0 115.2 2-5/16 59 A2 14817 VK350 - 20 mm 8.0 115.2 2-5/16 59 A2 06764B VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 A2 Small 4 _Orifice 06717B5 I VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Approved Finishes Approved Temperature Ratings I - Brass and Chrome-Enloy A- 135°F (57 °C), 155°F (68 °C), 175 °F(79 °C), 200°F (93 °C), and 286°F (141°C) 2 - Brass, Chrome-Enloy, White Polyester',, and Black Polyester' Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response Non-Storage pendent sprinklers. For specific application and installation requirements, reference the latest appli- cable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Approvals as the standard colors. The sprinkler orifice is bushed. DESIGN CRITERIA - FM Also r.firtr ppmvi1 Car: 2 FM AorovaI Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-Storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. THIS PAGE INTENTIONALLY Form No. F_080488 Replaces page 51a-e, dated August 4, 2011. (Revised main image and VK300 part number, removed brand name and replaced with PTFE)