Loading...
HomeMy WebLinkAbout5927 PRIESTLY DR; ; FPC2019-0046; PermitCr'city of PIERMJtT REPORT Carlsbad Print Date: 12/06/2024 Permit No: FPC2019-0046 Job Address: 5927 PRIESTLY OR, CARLSBAD, CA 92008-8800 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120610800 Track U: Applied: 03/07/2019 Valuation: $0.00 Lot U: Issued: 03/14/2019 Occupancy Group: Project U: Finaled Close Out: 09/25/2019 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Salcedo, Felix Plan Check U: Project Title: Description: UNITE PACIFIC COMMON AREA -SPRINKLER TI (15 HEADS) Applicant: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION AMERICAN AUTOMATIC FIRE SUPPRESSION INC INC JAZZMIN DEEKEN 9925 PROSPECT AVE, #STE B 9925 PROSPECT AVE, U B SANTEE, CA 92071 SANTEE, CA 92071 (619) 562-3010 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov tLicia Fire Protection Products C2o -oo4 Worldwide www.tyco-fire.com Contacts I Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.61K, 1/2'S NPT TY323 ......Pendent 5.61K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar1/2) FEBRUARY 2014 --. Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly Deflector * DEFLECTOR* 7/16 (11,1 mm) NOMINAL MAKE-IN 2 (50,8 mm) 1/2 NPT** ESCUTCHEON PLATE 1/2 7/161 SEATING SURFACE NPT** NOMIN 0=6 (50,8 mm) 1-3/8' (34,9 mm) WR F1 DEFLECTOR* STYLE 15 or 20 :11,1 mm) RECESSED L MAKE-IN ESCUTCHEON 2-7/8" (73,0 mm) DIA. *Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector can be provided on special request. 4 - Bulb 5 - Compression Screw CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135'F (57'C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) - 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8' (15,9 mm) (9,5±7,9 mm) \ ___ ___ _______ FLUSH ____________________________________________________________________________________________________ I 3/8±5/16' MOUNTING \_ (32 _____ mm) SURFACE ______ CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 3/4 (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) (7964 mm ) 1/2 (12,7 mm) i H FLUSH ,7 F~ 177' / MOUNTING SURFACE / (3,2 mm) / CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N* 77 - XXX - X - XXX I SPRINKLER TEMPERATURE I FINISH RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2NPT) TY313 3 PURE WHITE (RAL9010)** POLYESTER 371 56K PENDENT (1/2 NPT) TY323 POLYESTER SIGNAL WHITE (RAL9003) * Use suffix for ISO 7-1 connection, 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales only TABLE A SERIES TV-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F(57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP 770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark at The DuPont Corporation. Fire Protection Products Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (°F) (°C) I ps bar psi bar psi bar bar -200 to 1500 -28.9° to 301: 65.6° 20.7 500 34.5 600 41.4 200° 93,30 26 18.3 455 31,4 550 37.9 2500 121.10 22E 15.5 405 27.9 505 34.8 3000 148.90 18 12.8 360 24.8 460 31.7 3500 176.7° 151- 10.3 315 21.7 415 25.6 4000 204.4° 11( 7.6 270 18.6 370. 25.5 450° 232.20 Th 5.2 225 15.5 325 22.4 500° 260.6° - - 180 12.4 1 280. 19.3 550° 287.8° - - 130 9.0 1 230 15.9 Note: Unions with Copyar or Ccpps Alloy seats are not intended fo use where tempeea:ura exceeds 4 50°F c®us APPROVED For Listings/Approval De-ails and Limitations, visit our websito www.anvilintl.com or ortact an Anvil/AnvilStar Sales Representative. Mal lea ole Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 ___________ Sites V'-l' '&•25 inta Sites 1/ -2' 32 51 irm) Sites 2% '3" 1164 76 rem) (°F) '°G,l psi I 'bar' psi bar psi La psi bar -20° to 150° 28,90 to 300 20.7 2,000 65.60 137.9 1,50C 103.4 1,000 68.9 200° 93.3 265 15.3 1,785 123.1 1,350 93.1 1 910 62.7 2500 121.1 225 15.5 1,575 108.6 1,200 82.7 325 56.9 3000 148.9 185 t2.8 1,360 93.8 1,050 72.4 735 50.7 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 5500 287.8 - - 300 20.7 300 29.7 300 20.7 F- - 0 E 0 Anvil Class 150/30 Malleable Iron Fittings conform to ASME j B16.3 and Unions conform to ASME B16.39. ALL ELBOWS & TEES %' (IC ON) and LARGER ARE '00* GA TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) - - _ 0 : .1*CL (er CL ' co . Awiaim- : Li k CL I .. :•: (j[P I LI IL NO - ww ~O-~ >. 2 0 1) w in :3 - w (I) 0 0 2 -J -I m - 7. At rr - H rLTi iD VA I !7A D ull Moose Tube® is a customer focused, D" growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by r. ,rrr;rr f.r .r,riI -trrmnrc OLI IIVII IJ .)U1JI Ru III ICIlILIUl JI 1¼J1 11101 ILL. www.BullMooseTub ___ 0 \ it?m _SCHEOULE 4 800.325.4467 T, EDIDYLITEA - 440y. 1/ BULL MOOSE TUBE COMPANY ( c®us LISTED <9> APPROVED mo 7*\ ONF4 NFPA I Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED <9> APPROVED, 1] 4 s oiw!SA NFPA' ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. 'Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 4fl® I ijlit threddable Schedule 40 replacement with corrosion resislarice ratio of 1.0. Eddylite®: Liglrtwall threadable with standard outside dianielet. Eddy Flow®: Cost effective replacement br Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube° reserves the right to change product specifications without notice and without incurring obligation. ull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose TubeO made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testingas our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to.meet FM & UL specifications. — r c®us LISTED <9> I APPROVED (;] 4 ONFSA s1 ri SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 1527 141 lbs/ft 1.820 91 -1 _-1/47 L TTJ 2J [ -9-91----1 ilbfF 2'_5l 8 1 1-1/2 1.900 1.682 7.76 2.09Ibs/ft 3.053 61 - 627 LTI2IIT _j iT.iT] ETEITTE1 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3.500 Jr__3. M i 4 4.500 4.260 2.50 -, 5.62 !bs/ft 1 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINALPIPE O.D. I.D. WATER FILLED BUNDLE - ------ SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 --70- 1-1/4 _._! L 1 660 [ 1 3801 [ fö I fll 2918l L_51 11/2 1 900 1.610 1.00 - 2 72 lbs/ft - 166-2 - 375 J [T67 J 1 00 [3 66 Ib/ft 5 1 1 1_3- 2-1/2* i 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 F_3*3_500 3_068][i_00 jl 7_58 lbT10_7831r _ - 4* - - 4.500 - 4.026 1.00 - 1080 lbs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIIrnoosetube.com C~, ~0 Or From Canada Call (800) 882-4666 sales@builmoosetube.com 8 - 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Case Grande, AZ Dallas, TX Masury, OH BULL MOOSETUBE COMPANY 63017 STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 Trim piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com vICTAUlJc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVG \4taulicr 10.52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 _________ 1¼ ½ 15¼ I 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 1 33.0 46.5 2712 4 98.34 65.0 0.45 a/4 1,83 1.10 3.87 2.56 1.1 1Y 1.28 20 1 30.2 32.5 1 1¼ 1.52 46.5 2.18 27.9 1.10 98,3 65.0 387 . 2.56 98.3 65.)) 0.50 1.2 (1.54 1½ 40 25 ½ 15 30.2 j 38,6 (ISo 1 1.42 30.2 36.1 55.4 1.95 _495 , 27.9 1.22 0 4.08 2.56 r03.6 1.2 L -2-51 Y4 13¼ 1,40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.)) 103.6 65.)) 0,54 (ISo 1.64 1 2,3)) 1.22 4.08 2.56 1.3 25 30.2 41.7 58,4 31.)) 103.6 65.0 4.60 2.56 059 ) 1,3 2 1/1 15¼ 1.66 2.19 1.46 50 15 30.2 42.2 55.6 37.1 ' 116,8 65.0 059 15¼ ' 1.64 2.19 1.46 Y~ 4.60 2.56 1.4 20 30.2 I 41.7 55.6 1 37.1 116.8 65.0 064 11¼ 1,88 1.5 1 2,54 1.46 4.60 2.56 25 30.2 47.8 64.5 37.1 116.8 I 65.0 0.68 1.6 2½ ½ (ISO 1.91 2.44 1.71 5,40 j 2.56 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 11¼ 1,89 2.44 1.71 3/4 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 073 (ISo 2.13 1 2.79 1 1.71 5.4)) 2.56 1.6 25 30.2 54.1 7012 43.4 137.2 65.0 033 76.1 reIn ½ X lslo 1.91 2.44 1,71 5,5)) ' 2.56 1.6 15 30.2 48,5 62.0 I 43.4 139.7 65.0 ((.73 t2.Sô Y4 11¼ 1,89 2124 1.71 5.50 1.6 20 30.2 48.0 62.0 i 43.4 139.7 4 65.0 ((.73 1 Y16 2.13 1 2.79 1.71 5,5)) 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 _65.0 _080 FireLock® Outlet-I STYLE 922 DIMENSIONS Ipint t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result In assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions ale approximate). www.victaulic.com vrcTAuLrt; IS A REGISTERED TRADEMARK OF vrCTAuLrc COMPANY. 02)8)9 \SCTAULrc COMPANY. ALL RIGHTS RESERVED. 10.522 J4tauIic0 REV PS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 PERFORMANCE Run Size e Outlet Size Equivalent Length of inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)*, FT Ftiiter 40 x 25 2.6 -I Hazen-Williams coefficient of ifictiori is 120 FireLock® Outlet-T STYLE 922 www.victaulic.com tauIac VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY ALL RIGHTS RESERVED, REVO 10.52 .1 3 STYLE 922 INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV 0 UPDATED 12/2009 4-nt-aulic ViCTAULiC IS REGISTERED TRADEMARK OF viCTAULiG COMPANY. FT 21109 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 thru 4 inch pipe LISTED FOR STEEUCPVC 112&3/4 inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8' or 1/2' SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - C®US 203-EX 2551 1"- 8" Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW.-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 131), these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA13 PIPE ROD I WI. 5 WT.+250 UL TEST LOAD I 318 30.75 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 634.75 750 21/2 3/8 11835 841.75 850 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711.00 3805.00 4050 551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON#300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCONprodncts are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- .4 FCON will NOT warrant against site failure of its products when used its combination svitls other products, parts orsystcnss not manufactured or said by AFCON. AFCONshatl NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited In loss of business or profit, when ston.AFCONproduct,s have been, or are used. 1/08 ONI IkI 3 LA Not less than 2 nominaIvdth 00 Flooring Wood Product Features 4l11/2 ) No pre-drilling required. Notiesothon 1 Quicicto install using the Sammy I .IJ Nut Driver with an 18V cordless thickness (2-l/?( (depth or side Wood Joist drill/driver. of vertical member( r - I! Saves time from traditional Double 5heetioctc methods Ceiiin Reduces installation cost. 25-380. recommended *Pre-drilling Composite Truss installation point may be required for Tool available at? page GST 10, Made inthe U.S.A. Approvals Rod Size Part Number Model Screw Descri ptions Uitimate Pullout (Ibs) UL Test Load I'M Test BOX Obs) Load (lbs) City Cas M'. 04 1/4 8002957 GST 100 1/4 xl' 210 (7/16'OSB) 25 125 - 1/4 8003957 GST 200 1/4x2" 1760 (Fir) 25 125 1/4' 8004957 GST 300 1/40 3' 2060 (Fir) 2512IIj 3/8' 8006957 GST 75 1/4 x 3/4 564 (3/4 Ply) 25 125 3/8" 8007957 GST 10 1/40 1' 210 (7/16'OSB) 300 25 125 3/8' 8008957 GST 20 1/4x 2 1760 (Fir) 850 1475 25 125 3/8 8068925 GST 20 SS 1/402 1760 (Fir) 850 25 125.] 3/8 8009925 GST 25-380 3/8x2-1/2° 2113 (Fir) 1500 25 125 E.0 3/88o10957GST 301/403_2060 ()_150014752512.J 3/8' 8069925 GST 30-SS 1/40 3' 2060 (Fir) 25 125 I_3/88011925 GST 4O1/4s4__2180 Fir) 25125_J 3/8' 8012925 GST 60 1/4x6 2230 (Fir) 25_ -- 125 : 8013925 GST2J/4x2__1760(Fir) 25 i'j 1/2' 8014925 GST 2.5-380 3/8x2-1/2'2113(Fir) 25 125 1/211 8015925 qqj3 - 2275 [r) 1/2"8016925 GST 4 1/4x4'_2180(Fir) 25 125 [ _1_/2"____801.7925_ GST6 1/4x6________2230 -(Fir), 25T] ii #14 Black Nut Driver Part #8113910 k #14 SW Red Nut Driver Part # 8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3 1/a" x 12 pitch roof. • Reduces installation cost. 11 Allows 17° deflection from vertical. • Made in the U.S.A. I 4? UL Test Fill Test Min _•.M.t.rew _Thickness 20,_1l4x2 .. ........1257(Fir). --1050 1475 - 25125125 3/8 81419b/ SH.GSI 30 1/4x3" 1720 (Fill 1500 1475 __5_1_25__'_ #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and sate installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free, Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com 4-"" (0 .. V _A =1141333 El LIJ Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an iSV cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. a Not loon them 2' nominal width (1-1/2') up to 342' pipe; not loss than 3' (2-1/2') nomhal width 4' 85' pipe 4 I Minimum 2-1/2' from bottom for branch lines. Minimum 3' from bottom for main lines. Exception: This requirement shall not apply to 2' or thicker nailing ships resting on top of steel beams. Flow Joist a at E7 Q~ 1/4 1/4' ,N klnlmsc, 8018957 8019957 SWG 100 SWG 200 114x 1" 1/40 2' .pn.e,umLu,I.-p.o..snyw .pun(gp.w. 622Lft 1725 (Fir) 25 25 125_J 125 il 3/8 8020957 SWG 10 1/4 x" 622 (Fir) 300 25 125.] - . 3/8' 8021957 SWG 20 1/402' 1725 (Fir) 1050 25 125 3/8' 8073925 SWG 20-SS /4 x 2' 1725 (Fir) 850 25 12J #14 SW Red 4-. 3/8" 8022925 SWG 25-380 3/80 2-1/2 2249 (Fir) 1500 25 125 Nut Driver I 3/8' 8023925 SWG 30 1/4x3" 1884 (Fir) 25 125] Part #8114910 n Insert the appropriate nut driver into a 3/8" or 1/2" portable drill Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight 5 the member When the nut driver spins freely on the SAMM'S, stop drill and remove. The SAMMYS is now ready to receie 1/4", 3/8", 1/2" or metric all thread rod, boll stock. (The 1/2" r?quires the #14S W red nut driver) Note: When installing DSTR, follow thst above instructions, then add retainer nut and torque to 20 root lbs. for maximum pullout in purlin steel. LWIf Insert the appropriate nut driver into a 3/8" or 112"portable drill. Insert the SAMMYS into the #14S W (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note; When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. a SPECIAL NUT DRIVER SYSTEM: The not divers were designed with a unique spin-off feature which provides a fast and safe installation each lime. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate not driver for installations.