5927 PRIESTLY DR; ; FPC2018-0156; Permit
I:iii1Ii 1]i Lcity of Carlsbad Print Date: 12/06/2024 Permit No: FPC2018-0156 Job Address: 5927 PRIESTLY DR, CARLSBAD, CA 92008-8813 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Track #: Applied: 05/16/2018 Valuation: $0.00 Lot #: Issued: 05/29/2018 Occupancy Group: Project #: Finaled Close Out: 04/05/2021 ifof Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Wong, Cindy Plan Check 4*: Project Title: Description: HARSCH RUTHERFORD CORPORATE CENTER -SPRINKLER TI (47 HEADS) Applicant: FPContractor: HAMILTON FIRE PROTECTION INC HAMILTON FIRE PROTECTION INC MATT HAMILTON 25060 HANCOCK AVE. 4* STE 103 25060 HANCOCK AVE, U STE 103 MURRIETA, CA 92562-5930 MURRIETA, CA 92562-5930 (951) 834-6305 (951) 348-2068 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov H Hamilton Fire Protection, Inc. 25060 Hancock Ave., Suite 103 Murrieta, CA 92562 Phone (951) 834-6305 Fax (951) 848-0966 License# 883855 / 016 Material Cut Sheet Submittal for: Harsch Rutherford Corporate Center T.I. 5927 Priestly Dr. Carlsbad, CA 92008 Date: 5-15-18 I I By: LM I Trust Bull Moose when it comes to protecting your most valuable assets. As the leading manufacturer of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. BULL MOOSE ADVANTAGES: UL listed (US & Canada) and FM approved ASTM A135 and A795 Type E, Grade A Certified Complies with NFPA-13, 13R and 14 Industry-leading hydraulic characteristics. CRR of 1.0 and greater All pipe NDT weld tested OTHER BENEFITS/SERVICES: We have the most stocking locations in industry, for best delivery and availability Plain end or roll groove Eddy Guard IV bacterial-resistant internal coating Custom length options Hot dipped galvanization Reddi-Pipe® red pipe to eliminate field painting Compatible for use in wet, dry, preaction and deluge sprinkler systems c®us LISTED <@APPROVED NMI N F PA spdnkle. AoWton Bull Jill]ProductT4r1Iinformation Q1 I Ip ' w 90 l &W 0.0. (in) 1.660 1.900 2.315 2.875 3.500 4.500 I.D. (in) 1.530 1 1.728 2.203 2.705 3.334 4.310 Empty Weight (lb/It) 1.222 1.844 2.330 2.809 3.351 4.968 Water Filled Weight (lb/It) 2.019 2.860 3.982 5.299 1.144 11.290 U- >_ C.R.R. 1.98 3.44 2.78 1.65 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 LU Lift Weight (Ibs) 21 lengths 1,565 2,362 1,810 1,170 1,341 1,982 Lift Weight (Ibs) 24 lengths 1,799 2,100 2,069 2,022 1,533 2,265 Lift Weight (Ibs) 25 lengths 1,864 2,812 2,155 2,101 1,596 2,360 0.0. (in) 1.315 1.650 1.900 2.375 2.875 3.500 4.500 6.625 8.625 I.D. (in) 1.097 1.442 1.682 2.151 2.635 3.260 4.260 6.351 8.249 Cz Empty Weight(Ib/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 LLI Water Filled Weight (lb/It) 1.820 2.518 3.053 4.223 5.893 1.957 11.796 23.038 40.086 C.R.R. 15.21 9.91 7.16 6.27 4.92 3.54 2.50 1.158 1.805 LAJ Pieces per Lift 91 61 61 31 30 19 19 10 7 LA Lift Weight (Ibs) 21 lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 Lilt Weight (Ibs) 24 lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 Lift Weight (Ibs) 25 lengths 3,208 2,160 3,181 2,442 2,648 2,062 2,610 O.D. (in) 1.295 1.650 1.900 2.315 I.D. (in) 1.083 1.418 1.645 2.123 Empty Weight (lb/It) 1.461 2.070 2.547 3.308 Water Filled Weight (lb/It) 1.860 2.154 3.468 4.842 C.R.R. LLJ 1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 Cll Lift Weight (Ibs) 21 lengths 2,148 2,211 2,353 2,084 LIJ Lift Weight (Ibs) 24 lengths 2,454 2,534 2,690 2,382 Lift Weight (Ibs) 25 lengths 2,551 2,639 2,802 2,481 O.D. (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 I.D. )in) 1.049 1.380 1.610 2.061 2.469 3.068 4.025 Empty Weight(lb/ft) 1.680 2.210 2.120 3.660 5.800 7.580 10.800 Lai water Filled weight (lb/It) 2.055 2.918 3.602 5.114 1.815 10.183 16.315 Cll I.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 LU Pieces per Lift 70 51 44 30 30 19 19 Lift Weight (Ibs) 21 lengths 2,470 2,431 2,513 2,306 3,654 3,024 4,309 Lift Weight (Ibs) 24 lengths 2,822 2,118 2,872 2,635 4,176 3,456 4,925 _j Lift Weight )Ibs) 25 lengths 2,940 2,894 2,992 2,745 4,350 3,601 5,130 Threaded Mechanical Branch Tee Model MT-30 mechanical tee serves the same function as MT. 1 & MT-8 but uses a steel electro-plated U-Bolt to save space and for easier installation in tight places. It is ideal for direct connections with sprinkler heads and drop nipples. iNiLStar Fire Products Division of Anvil' International Submittal Sheet UL C APPROVED For Listing /Approval details contact your AnvilStarmi Representative. I A WARNING For dry pipe systems and freezer applications lubrication of the gasket is required, Gruviok® XtremeTM Lubricant is recommended. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12. U-BOLT & NUTS: li-bolt is carbon steel SAE Grade 2, Zinc Plated with plated hex nuts carbon steel ASTM A- 194, Zinc Plated. THREADS: MT-30 NFl per ANSI/ASME B1.20.1 COATINGS: Zinc Electroplated Other (Specify): Example: RA13000 or RAL9000 Series For other Coating requirements contact an AnvilStor Representative. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. 1 Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range) (-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, salts, oil-free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS. Ci Other :I'!11sIINFORMATION: APPROVAL STAMP: i Project: Date: Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: PAGE 10F2 SPF Couplings, Fittings, Flanges, Clamps For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06-0033 go to www.anvilslar.com or contact your local AnvilStar representative A-WALBtar- Threaded Mechanical Branch Tee Fire Products Division of Anvil* International Submittal Sheet f I- !jIc1u MECHAMICAL 11* Nominal Hole Diameter Max. Wk. Dimensions Approx. Mm, Max. A B c Size 0. D. Pressure Wt. [a. Diameter Diameter Take-Out In1DN(mm) In./mm In ./mm In ./mm PSI/bar InJmm In1mm In/mm In ./mm Lbs/kg 11/4 x ½ 1.660 x 0.840 1/16 1.10 300 21/8 31h 21/4 1/8 0.8 32x /2 42.4x21.3 30 33 20.7 54 89 57.2 42 0.4 11/4 x 1/4 1.660 x 1.050 1/16 1/I6 300 2'/u 31h 2% 1/8 0.8 32x19 42.4x76.7 30 33 70.7 54 69 57.7 47 0.4 11/4 4 1 1.660x1.315 1A6 1A6 300 21/4 31h 21/4 1/e 1] 32x25 42.4x33.7 30 33 20.7 58 89 57.2 41 0.5 1½ /2. 1.900 x 0.840 13/16 15/16 300 21/4 31/2 21/4 13/4 0.8 40x 12 48.3x21.3 30 33 20.1 51 89 51.2 48 0.4 1½ x'14 1.900x1.050 1/16 1/16 300 21/4 31h 21/4 13/4 0.9 40x /9 48.3x26.1 30 33 1 20.7 51 89 51.2 48 0.4 1½ x 1 1.900x1.315 13/16 1/16 300 2/t 31/2 21/4 1/4 1.1 40x25 48.3x33.7 30 33 20.7 61 89 57.2 44 0.5 2 x ½ 2.315x0.040 V/i, 300 2½ 33/4 21/4 2 0.9 50x12 60.3x21.3 30 33 20.1 64 95 57.2 51 1 0.4 2 x 3/4 2.315 x 1.050 11 6 iAt 300 21h 33/4 21/4 2 0.9 50X 19 60.3x26.1 30 33 20.7 64 95 51.2 51 0.4 2 x 1 2.375 x 1.315 13/16P,ls 300 2/ 33/4 21/4 2 1.1 50x25 60.3x 33.7 30 33 20.7 61 95 51.2 50 0.5 2½ x ½ 2.875x0.840 1 /16 1 5A 300 23/4 41/4 21/4 21/4 0.9 65x17 13.0x21.3 30 33 1 20.1 70 108 51.2 51 1 0.4 21it it 1/4 2.875 x 1.050 1/I6 ]5,14 300 2/4 4% 21/4 21/4 0.9 65x19 73.0x26.7 30 33 207 70 103 57.2 57 0.4 21/2 x 1 2.875 x 1.315 1/16 1/l6 300 2/ 41/4 21/4 21/4 1.1 65x25 1 73.0 e33.7 1 30 33 20.7 73 1 /08 51.2 56 0.5 BSP equivalent is available as a MT-90. NOTE: Tighten nuts alternatively too recommended torque of 18-22 ft-lbs (25- 30 N-ml on pipe wall less than schedule 10 or 23-27 ft-lbs (31 -37 N-m) on pipe walls schedule 10 and above. PAGE 2 OF 2 SPF Couplings, Fittings, Flanges, Clamps For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06-0034 go to www.anvilstar.com or contact your local AnvilStar representative 4/9/2014 Print ANVIL Q:F~- ~--!QiP Malleable Iron Screwed Fittings - Class 150 MATERIAL SPECIFICATIONS USTD PPflOVEO øtt4 4rd V44 f" 4 1,s *!L1 im fl1* REDUCING COUPLh[r JonioI Size Dimenian A Approx. Wt. Fnh ki k. ( thi (kg) X 1.00 0.07 1.13 0.09 1.13 0.10 Tod 2j 1.25 1.25 0.13 ).i r V, aij, VPl 1,25 014 t 705 61 f15 144 018 144 020 1.44 v.21 hx½ 1.44 0.22 U ... , . 41 ix 1.69 0.34 2.06 0,47 2.06 52 _________________ Elf xi 2.06 0.51 1½x 2.31 062 I 1h X Y4 2.31 0.66 O3' Pix 1 2.31 0,73 51~cli 0,11.1 1½o 1% .......0,80 http:/Mw.anAJintI.carrvProductSearch/PrintProductasp?Iid=4379 Dimensional: Filings: ASME 816.3 Unions: ASME B16,39 Bushings/Plugs: ASME B16.14 Material: ASTM A.1 97 Galvanizing-, ASTM A-153 (Hot Dip Galvanizing) Threading*: ASME 81 .20. 1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 916-39 Bushings/Plugs: ASME .816.14 Pressure Testing: All malleable iron Fittings are tested For through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions are UL Listed and FM Approved. * Briish Siandard threadng per 6$ 21 ovoilobte upon request. REDUCING COUPLING Nominal Site Dimension A Approx. Wt. Ead 4 th. 2.81 0.94 1U1 043 2 281 0.99 2x1 2.81 1.03 7x1 2.81 117 116 2.81 L25 Thx 4 3,25 L81 24xl 3.25 1.90 2c 006 Th x 2 3.25 2.04 3x I 369 2.48 ,yc 01 ?3 t2 . t 3x Th 3.69 2.5 3x fl 3.69 7.67 3x 2 3.69 2.78 3 x 21,i 3.69 :3.23 147 4 x 2 4.38 4.43 4x2 4.38 4.81 4 x 3 4.38 5.29 112 iffe APPOtEO VAPWWjJ WI& 4 *'f *n 4/9/2014 Print Cd ES: /~ ~- L> Malleable Iron Screwed Fittings - Class 150 tIk1 :[.Tj' Nominal Size Dimension A Approx. Wt. Eorh in. (OW thi (kg YJ 0.69 0,010 0.81 0.10 0.95 0.15 112 022 1.31 0.36 1 1.50 0,57 1,7 0.87 Ph 1.94 1.16 2 2.2S 1.81 Th 7.70 123 I IQ 3 3.08 4.82 4 3.79 8.41 6 S.13 19.96 F-MATERIAL SPECIFICATIONS Dimensional: Filings: ASME 816.3 Unions: ASME 8 16.3 9 Bushings/Plugs: ASME B1o.14 Material: ASTM A-i 97 Galvanizing: ASTM, A-153 Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: FitfiAgS ASME BI 6.3 Unions: ASME BI 6.39 &shings/Plug.s: ASME 816.14 Pressure Testing: All ffiolIble iron fittings ore rested for through wall porosity using an air under water process. .Agency Approvals: All malleable iron fittings and unions are UL Listed and FM Approved. ' Briish Siaidcn'd threc3ding p& BS 21 availoble Upon request. http://wm.anlintl.comlProductSearch/PrintProduct.aspOIid=4370 112 A I MYS° 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST20SS X 2-1/2 850 1.5 8010957 GST30 X 4 1500 1.5 X 4 1475 1.5 8009925 GST25-380 X 4 1500 1.5 8022925 SWG25-380 X 3-1/2-4° 1500 1.5 8021957 SWG20 X 2-1/2-3°" 1250 1.5 8073925 SWG2OSS X . 2-1/2 1250 -1.5 8139957 SHGST20 X 3 1050 1.5 X 4 1475 1.5 8141957 SHGST30 - X 4 1500 1.5 X 4 1475 1.5 UL Max Pipe UL Test Mm, Steel FM Max FM Test Mm. Steel Part No. Steel UL FM . Size, n. i Load Thickness, n. i Pipe Size Load Thickness, in. 8038957 OSTR1 X 4 1500 .035 X 4 1475 .1050 8037957 DSTR 1-1/2 X 4 1500 .035 X 4 1475 .1050 8039957 DSTR516 X 4 1500 .037 X 4 1475 .1050 8045957 DST 516 X 4 1500 .188 X 4 1475 .1875 8046957 TEK50 X 4 1500 .250 X 4 1475 .1875 8055957 SWDR 1 X 4 1500 .037 X 4 1475 .0600 8056957 SWDR 516 X 4 1500 .037 X 4 1475 .0600 8054957 SWDR 1.1/2 X 4 1500 .037 X 4 1475 .0600 8137957 SHDSTR1 X 4 1500 .035 X 4 1475 .1050 8150922 XP 20 X 2-1/2 850 .027 X 4 1475 .1050 8153922 XP 35 X 3-1/2 1250 .043 X 4 1475 .1050 8294922 SXP 20x X 2 750 .027 X 4 1475 8295922 SXP 35 - X 3-1/2 1250 .060 X 4 1475 8293957 SWXP35 X 3-1/2 1250 .060 X 4 1475 UL Max Pipe UL Test . FM Max FM Test Part No. Concrete UL Mm. PSI FM Material i Size, n. Load Pipe Size Load 8059957 CST 20 3000 X 4 1475 3000 PSI 8061957 SWC20 3000 X 4 1475 3000 PSI 8150922 XP 20 X 2-112 850 Pre Pour Structural 3000 PSI 8150922 XP 20 X 2-1/2 850 Post Pour Range II LWC :5 35 PCF SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" °SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4° °SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" Sff/G 20 Maximum pipe size in wood timber or joist allowed by UL is 2-1/2" ASXP 20 Maximum allowable angle in 22 ga. steel is 450 UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weighth of water filled schedule 40 pipe 250 pounds. P\ nBudex www.itwbuildex.com 800-BUILDEX SSS39 082007 IMPERIAL MAX REC. LOAD LBS. METRIC PIPE ROD PIPE ROD 1/2 3/8 400 10 3/4 3/8 400 20 tO 3/8 400 25 1 10 11/4 3/8 400 32 10 11/2 3/8 400 40 10L. 2 3/8 400 50 tO 2112 3/8 600 65 to 600 80 to 31/2 3/8 600 10 3/8 1000 5 1/2 1250 125 12 6 1250 iso t 8 1250 Order Part #300m Note: 1/2 Ring Hanger not <FM> approved PE A B I Ism t 1 114 2.1343 2.7843 I 112 zam tallo 2 24B 8,4310 2112 3AW 411143 3 &Th46 4.4311 4 4,3 4.0043 B SC008 0M43 B 1.5788 8.O 1/2 and 3/4 inch pipe 5 thru 8 inch pipe P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 thru 4 inch pipe LISTED FOR STEELICPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - 203-EX 2551 Approval guide - Pipe Hangers OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION -Per NFPA-13, 13R and 13D. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. 2/07 L'1 Worldwide www.tyco-fire.com Contacts Series RFII - 5,6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFll 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate/ Retainer Assembly and a Sprinkler/ Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. NflI)tL.I The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. MARCH 2013 1Y3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/p5i112 (80,6 LPM/bar1'2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFPI8I SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO H RETAINER SUPPORT fi WITH THREAD CUP UNTIL 0 0 _- DIMPLES MOUNTING I SURFACE IS 11 EJECTION FLUSH WITH El SPRING CEILING H / SOLDER -' '-_. COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY 1/2 NP1 FRAME SUPPOR CUP WIT] ROLL FOR1 THREAD GUIDE PINS (2) DEFLECTOR ------------ EALING SEMBLY CAP BULB PRESSION CREW LECTOR ROPPED POSITION) TFPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ TEFLON Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. NL.Jt(. Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200'F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION C SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING 74- SURFACE MOUNTING Fx I ' 3/16 to 11/16' MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE - PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. WiL•J1LI As long as the Protective Cap remains in place, the system is considered "Out of Service" Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate! Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFPI8I Page 4 of 4 Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, "Royal Flush II" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C) 200°F (93°C) TY3531 51-792-1-155 51-792-1-200 1Y3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003) .... 56-792-4-135 56-792-4-165 Jet Black (RAL9005) .... 56-792-6-135 59-792-6-165 Brushed Chrome........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. INCIP TEFLON is trademark of The DuPont Corporation. ur rVag 0) Fire Protection Products Worldwide www.tyco-fire.com Contacts I Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (1Y313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 IA(I)i(•l The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psil/2 (80,6 LPM/bar1/2) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* 5 t 7/16 (11,1 mm) f /fl"••\\ ______ _____ MAKE-IN _____ (50,8 mm) 4 _____ P NOMINAL 2 F1 2 1-3/8 3 (50,8 mm) I(34,9 mm) / ill I WRENCH _______ FLATS 1/2 NPT** DEFLECTOR * 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS (USE ONLY END FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm), Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TV-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLE AO FITTING 5/8"(15,9 mm) FLUSH 3/8±5/16 MOUNTIN 1/8" SURFACE _(3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON -* 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4" (7,9±6,4 mm) 1/2" (12,7 mm) FLUSH I MOUNTING 1/', SURFACE/ \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77XXXX_XXX I I I SPRINKLER TEMPERATURE I FINISH -J- RATINGS SIN 1 NATURAL BRASS I 370 5.6K UPRIGHT (1/2' NPT) TY313 3 PURE WHITE (RAL9010)°° 155 155°F POLYESTER 371 5.6K PENDENT (1/2 NPT) 1Y323 POLYESTER SIGNAL WHITE (RAL9003) Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F (57°C) (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F(141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqcc TEFLON is trademark of The DuPont Corporation. Fire Protection Products