5901 PRIESTLY DR; 303; FPC2019-0004; Permit
PERMIT REPORT (city of Carlsbad Print Date: 12/06/2024 Permit No: FPC2019-0004 Job Address: 5901 PRIESTLY DR, # 303, CARLSBAD, CA 92008-8825 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120610300 Track #: Applied: 01/08/2019 Valuation: $55,439.92 Lot #: Issued: 01/17/2019 Occupancy Group: Project #: Finaled Close Out: 04/05/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fieri, Dominic Plan Check #: Wong, Cindy Project Title: Description: RED DOT - FIRE ALARM TI Applicant: RED HAWK FIRE AND SECURITY CA LLC ROBERT HASTINGS 920 S ANDREASEN DR, # 102 ESCONDIDO, CA 92029-1936 (760) 233-9787 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov FIRE ALARM SYSTEM TENANT IMPROVEMENT SUBMITTAL For RED DOT CENTERPOINT PLAZA 5901 PRIESTLY DRIVE, SUITE 303, CARLSBAD, CALIFORNIA 92008 Submitted By: RED HAWK FIRE & SECURITY 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 PROJECT INFORMATION SHEET PERMIT NUMBER: INSTALLING CONTRACTOR: CONTRACTORS LICENSE PROJECT MANAGER: PROJECT NAME: PROJECT ADDRESS: RED HAWK FIRE & SECURITY 920 South Andreasen Drive, Suite 102, Escondido, California 92029 Phone: (760) 233-9787 C-10/C-16 #713099, 11/30/20 John Stasukevich RED DOT Centerpoint Plaza 5901 Priestly Drive, Suite 303, Carlsbad, California 92008 SCOPE OF WORK: Fire Alarm System Tenant Improvement January 7, 2019 RE: Red Dot Centerpoint Plaza 5901 Priestly Drive, Suite 303, Carlsbad, CA 92008 Fire Alarm System - Tenant Improvement Red Hawk Fire & Security is pleased to submit the following equipment for your approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is sprinklered and monitored. QTY. MODEL NO. DESCRIPTION C.S.F.M. G1F-VM Multi Candela, Strobe, Wall Mount 7125-1657:0218 GI F-HDVM Multi Candela, Horn/Strobe, Wall Mount 7125-1657:0202 Notes: The existing Fire Alarm Control Panel is manufactured by EST and is compatible with all new & existing devices. Respectfully submitted, RED HAWK FIRE & SECURITY V1 ME =N\M V1 AMIN US, I Mq- MINIM I 11111m '50 =,itdZT, EDWARDS Catalog fr Strobes, Horns, Bells, Chimes nul 8218, 85389, 82970 MEA * 7125-1657:0202, 0218, 0284; 7135-1657:0230 FC (E LIFE SAFETY INCIDENT MANAGEMENT Field Configurable .. Horns and Strobes S' (5) Gle ECS/MNSappliancesavailab nesis with clear or amber lenses. L._ Overview The Genesis line of fire alarm and mass notification/emergency communications (ECS/MNS) signals are among the smallest, most compact audible-visible life safety signaling devices in the world. About the size of a deck of playing cards, these devices are designed to blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular re- flectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the UL-1971 and ULC-S526 light distribution requirements. Genesis strobes and horn-strobes offer selectable candela output by means of a conveniently-located switch on the side of the device. Models are also available that offer fixed 15/75 cd output. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent unauthorized tampering. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between fire alarm and mass notification alerts. Standard Features Unique low-profile design - The most compact UL-1 971 /ULC-S526 listed strobe available - Ultra-slim - protrudes less than one inch - Attractive appearance - No visible mounting screws Four field-configurable options in one device - Select 15, 30, 75, or 110 cd strobe output - Select high (default) or low dB horn output - Select temporal (default) or steady horn output - Select public mode flash rate (default) or private mode temporal flash Fixed 15/75 cd model available ECS/MNS models available Easy to install - Fits standard 1-gang electrical boxes - no trim plate needed - Optional trim plate accommodates oversized openings - Pre-assembled with captive hardware - #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Industry's most even light distribution - Meets tough synchronizing standards for strobes Single microprocessor controls both horn and strobe - Independent horn control over a single pair of wires - Highly regulated in-rush current - Multiple frequency tone improves sound penetration - Field-programmable temporal strobe output option Page lof6 DATA SHEET E850010573 Not to be used for installation purposes. Issue 1.1 Application Genesis strobes are UL 1971-listed for use indoors as wall-mount- ed public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. WARNING: These devices will not operate without electrical power. As tires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB and features a unique multiple frequency tone that results in excellent sound penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. Horn-only models may be ceiling-mounted or wall-mounted. The suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. ECS/MNS Applications Genesis ECS/MNS strobe appliances bring the same high- performance fire alarm features and unobtrusive design to mass notification applications. Available with amber lenses and optional ALERT housing labels, they are ideal for applications that require differentiation between fire alarm and mass notification alerts. Installation Genesis horns and strobes mount to any standard one-gang sur- face or flush electrical box. Matching optional trim plates are used to cover oversized openings and can accommodate one-gang, two-gang, four-inch square, or octagonal boxes, and European 100 mm square. All Genesis signals come pre-assembled with captive mounting screws for easy in- stallation. Two tabs at the top of the signal unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Genesis Horn/Strobe Field Configuration with optional trim plate Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. Units may be con- figured for use with coded systems by cutting a jumper on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal circuit. A Genesis Signal Master is required when horn- strobe models are configured for coded systems. Non-temporal, horn-only models sound a steady tone. Genesis clear strobes and horn-strobes are shipped from the fac- tory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting a jumper on the circuit board. This battery-saving feature is intended for private mode signaling only. Genesis clear strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output. The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horns, strobes, and combination horn-strobes are interconnected with a single pair of wires as shown below. Polarity shown in alarm condition To next appliance, end-of-line Or return to control equipment Note: Strobes must have continuous voltage. Page 2of6 DATA SHEET E850010573 Not to be used for installation purposes. Issue 1.1 Horns Wall or Ceiling Mounted Temporal Horns (G1-HD) UL Rating High dB (RMS) Low dB (RMS) 16 Vdc 26 19 24 Vdc 36 27 33 Vdc 41 33 16Vfwr 51 37 24Vfwr 69 52 33Vfwr 76 70 Current RMS RMS 17 19 22 26 30 34 38 47 Horns (GI -PI 16 Vdc 22 20 Vdc 24 24 Vdc 27 33 Vdc 32 16Vfwr 34 20 Vfwr 40 24Vfwr 45 33Vfwr 52 Wall or Ceilina Mounted UL Designation Voltage Range Max. Current, RMS Regulated 24 16 - 33 Vdc Vdc 13 mA 24fwr 16-33Vfwr 11 m Typical Current RMS 24 Vdc 10 24 Vdc 11 31 Vdc 12 20Vfwr 9 24Vfwr 10 Current values are shown in mA. Current Draw Strobes, Horn-Strobes MuItc&WallStrob(Gi'VMr UL 15 cd* 30 cd* 15/75 cd** ] 75cd -- 110 cd* Rating RMS RMS RMS RMS RMS - - 16 Vdc 103 141 152 255 311 16Vfwr 125 179 224 346 1 392 i-VM multi-cd; L1 --Vi 575 fixed 15/75 cd Typical 156d 30 cd 15/75 75 cd 110 cd Current RMS RMS RMS RMS RMS 16 Vdc 85 127 150 245 285 20 Vdc 71 98 123 188 240 24Vd 59 82 104 152 191 33 Vdc 46 64 84 112 137 16Vfwr 119 169 223 332 376 20Vfwr 103 143 189 253 331 24Vfwr 94 129 169 218 262 33Vfwr 87 112 148 179 205 Rating RMS RMS TRMS RMS RMS 16 Vdc f 129 167 172 281 337 16Vfwr 176 230 269 397 443 Typical 15 cd 30 cd 15/75 75 cd Lj10cd Current RMS RMS RMS RMS RMS 16 Vdc 102 135 160 246 309 20 Vdc 88 109 137 193 248 81 94 122 161 33 Vdc 74 72 106 124 154 16Vfwr 144 182 247 352 393 20Vfwr 141 162 220 274 362 24Vfwr 136 152 203 235 282 33Vfwr 125 144 196 201 232 Wall Temporal Horn-strobes - Low dB Setting Wall mpra1iHornstrobes,High,dB:Sethng UL *G1HDVM multi-cd **G1FH0V1575 fixed 15/75 cd 15 30 15/75 75 110 cd cd cd** cd* cd* I I I UL 15 30 1517T 75 1101 i I Rating cd* I cd I cd** cd* cd* RMS I RMS RMS RMS RMS 16 Vdc 122 I 160 146 274 330 16Vfwr 162 216 231 383 429 *G1HDVM multi-cd **G1 F-H0V1575 fixed 15/75 cd Typical { 15cd 30 cd 15/75J 75 ,,cd 110 Cd Current RMS RMS RMS RMS RMS 16 Vdc 96 130 158 243 302 20 Vdc 79 104 133 189 241 24 Vdc 68 88 119 156 197 33 Vdc 56 71 100 118 146 16Vfwr 128 180 241 344 389 20Vfwr 118 157 213 266 343 24Vfwr 113 144 195 230 279 33Vfwr 112 137 182 197 226 Page 3 of 6 DATA SHEET E85001-0573 Not to be used for installation purposes. Issue 1.1 dBA output Temporal Horns. Horn-strobes (G1-HD. G1-HDVM series High UL464 —J Average Peak dB - Setting Temporal [ Steady. Temporal! Steady Temporal! -Steady 16 Vdc 81.4 85.5 1 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc 86.3 90.4 1 96.9 1 99.5 Low dB UL464 --- -------- ----- Average Peak ____ Setting Temporal Steady Temporal! Steady Temporal/ Steady 16 Vdc 76.0 80.1 86.3 89.2 24 Vdc 79.4 83.5 89.8 92.5 33 Vdc 82.1 86.5 92.5 95.3 Steady Tone Horns (G1-P series) UL464 Average Peak 16 Vdc 77 dBA, min 85 dBA 91 dBA 16Vfwr 1 77 dBA, min 85 dBA 91 dBA Notes All values shown are dBA measured at 10 feet (3.01m). UL464 values measured in reverberant room. Average and Peak values are measured in anechoic chamber. Average Sound Output (dBA) (High dB setting, anechoic, 24V, measured at 1 Oft) Light output - (effective cd) Percent of UL rating versus angle Specifications Housing Red or white textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Lens Optical grade polycarbonate (clear) Strobes and horn-strobes are for wall-mount installation only. Horn-only models may be ceiling- or wall-mounted. Mounting Flush mount: 21/2 inch (64 mm) deep one-gang box (indoor only) Surface mount: Model 27193 surface mount box, wiremold box, or equivalent surface-mount box With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor only: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Agency listings/approvals UL 1971 (S218), UL 1638 (S218), UL464 (S218), ULC S525, ULC S526, CSFM, CE, FCC, MEA. (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) Dimensions (HxWxD) Signal: 4-1/2" x 2-3/4" x 13/16" (113 mm x 68 mm x 21 mm) Trimplate: 5 (127 mm); Height -5-7/8" (149 mm); Depth -1/2" (13 mm) G1-HD series temporal-tone horns: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc F\NR (or coded when horn set to steady tone) Operating voltage G1-HDVM series temporal-tone horn-strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional Gi M Genesis Signal Master) G1-VM series strobes: non-coded, filtered 16 - 33 Vdc or unfiltered 16-33 Vdc F\NR G1-P series steady-tone horns: coded or non-coded, filtered 20-31 Vdc or unfiltered 20-27 Vfwr UL 1971, UL 1638, ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 cd output Strobe output rating UL 1971: 15 cd (fixed 15/75 cd models) UL 1638, ULCS526: 75 cd (fixed 15/75 cd models) Gi -VM strobes and G1-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Strobe flash rate Gi M Genesis Signal Master indefinitely within 10 milliseconds. Temporal setting (private mode only): synchronized to temporal output of horns on same circuit SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS10A, APS6A, APS10A, i064, i0500, Fireshield Plus 3, 5 and 10 zone. Add G1 M for G1-CVM &G1 -HDVM devices only. Horn pulse I rate Gi -HD temporal-tone horns and Gi -HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely within 10 milliseconds. G1-P steady-tone horns: continuous, steady tone only Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, 11/2 sec OFF, then repeat cycle Page 4 of 6 DATA SHEET E85001-0573 Not to be used for installation purposes. Issue 1.1 Candela Output Fire appliances available with white or red housings. Lens Switch Color Rating Switch Position Switch Position Switch Position 1).\ ' Position A '.. t 777 Amber 0L1638 110 cd 75 cd 30 cd 15 cd Amber UL 1971* 88 cd 60 cd 24 cd 12 cd Clear UL 1971 110 cd 75 cd 30 cd 15 cd ECS/MNS appliances available with clear or amber lenses. * Equivalent Rating ALERT i ALERT w. . Ordering Information I Model Housing j Marking Lens Strobe Horn Ship Wt. lbs(kg) Fire Alarm Appliances (c/w running man icon screen printed on housing) G1-VM White None Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) Gi F-HD White FIRE Clear Horn only Selectable high/low dB 0.25 (0.11) Gi F-HDV1575 White FIRE Clear 15/75 Cd1 Temporal hi/lo dB-24V 0.25 (0.11) iEHDVM White FIRE Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) Gi F-P White FIRE Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) Gi F-V1575 White FIRE Clear 15/75 cd' Strobe only 0.25 (0.11) tG1-VtVj White FIRE Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) G1-HD White None Clear Horn only Selectable high/low dB 0.25 (0.11) G1-HDVM White None Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) GI-P White None Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) Gi RF-HD Red FIRE Clear Horn only Selectable high/low dB 0.25 (0.11) G1RF-HDV1575 Red FIRE Clear 15/75 cd' Temporal hi/lo dB-24V 0.25 (0.11) Gi RF-HDVM Red FIRE Clear Selectable 15, 30, 75, or-1 10 cd Selectable high/low dB 0.25 (0.11) G1 RF-P Red FIRE Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) G1RF-V1575 Red FIRE Clear 15/75cd1 Strobe only 0.25 (0.11) G1IRF-VM Red FIRE Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) G1R-HD Red None Clear Horn only Selectable high/low dB 0.25 (0.11) G1 R-HDVM Red None Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) G1 R-P Red None Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) G1R-VM Red None I Clear Selectable 15, 30, 75, or 110 cd I Strobe only 0.25 (0.11) ECS/MNS Appliances (no running man icon on housing) G1WA-VMA White I ALERT Amber I Selectable A, B, C or D Strobe only 0.25 (0.11) G1WA-VMC White ALERT Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) G1WN-VMA White None Amber Selectable A, B, CorD Strobe only 0.25 (0.11) Gi WN-VMC White None Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) Trim Plates G1T White None Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) GiRT Red None Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) Gi T-FIRE White FIRE Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) GiRT-FIRE Red FIRE Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) G1WT-ALERT White ALERT Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) Surface Boxes 27193-16 White N/A One-gang surface mount box 1 1(0.4) 27193-11 Red N/A One-gang surface mount box 1 1(0.4) 1 These 15/75 cd models provide fixed output and are not multi-candela devices. The 15 cd output component complies with UL1 971, while the 75 cd output component complies with UL 1638. Page 5 of 6 DATA SHEET E85001-0573 Not to be used for installation purposes. Issue 1.1 OWARDS [1FF SAFETY S INCIDENT MANAGEMENT Contact us... Email: edwards. fire@fs.utc.com Web: edwards-fire.com 1016 Corporate Park Drive Mebane, NC 27302 EDWARDS is a registered mark in the United States and other countries. © 2018 United Technologies Corporation. All rights reserved. Page 6 of 6 DATA SHEET E85001-0573 Not to be used for installation purposes. Issue 1.1 STATE FIRE MARSHAL LISTING SHEETS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models G1-VM, G1R-VM, GV1t G1RF-VM, G141575, G1R-V1575, G1F-V1575, G1RF-V1575, G1WA-VMC and G1WN-VMC synchronizable type strobe lights. The suffix R refers to red and W refers to white color enclosure; the suffix F refers to the word "FIRE" refers to a silk-screened word "FIRE" on the strobe housing; the A in the model number indicates (Alert) marking; N in the model indicates no marking. Intended for indoor and mounted on a wall only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 V dc/VFWR Candela GI-VM and G1W-VMC series 15cd, 30cd, 60cd, 75cd, 110cd Selectable G1-V1575 series 15/75cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Units are synchronizable when used with Models G1 M or G1 M-RM sync module (CSFM Listing No. 7300-1657:201) which may employ Models SIGA-CC1S or SIGA-MCC1S Auto-Sync output modules as an accessory (CSFM Listing No. 7300-1657:121). For indoor use and wall mount only. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:218 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VC operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7256570202 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST" G1-HV15, -HV30, -HV60, -HV-75, GI-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIF-HOV15, -HOV30, -HOV60, -HOV75, -HOV110,_GIRF-HOV15, .-HOV3O, -HOV60, -H0V75, -HOV110, G1-HDVM, G1R-HDVM, G1FHDVM G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, G1 R-HDV1575, G 1 F-H DV1575, and G 1 RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33 Vdc/Vfwr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, G1R-HDV1575, Gi F-HDV1575, G1 RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, Gi R-HDV1575, G1 F-HDV1575, G1 RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GCHDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division