Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5901 PRIESTLY DR; 302; FPC2017-0136; Permit
cCity of Carlsbad Print Date: 12/06/2024 Job Address: 5901 PRIESTLY DR, # 302, CARLSBAD, CA 92008-8825 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120610300 Track #: Valuation: $184,458.66 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2017-0136 Status: Closed - Finaled Applied: 05/22/2017 Issued: 06/20/2017 Finaled Close Out: 04/05/2021 Final Inspection: INSPECTOR: Fieri, Dominic Project Title: Description: CROSS COUNTRY MORTGAGE -SPRINKLER TI 7-100 HEADS (37 HEADS) FPContractor: COSCO FIRE PROTECTION INC 1075 W LAMBERT RD BREA, CA 92821-2944 (858) 444-2000 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date.. $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov San Diego B,izch Office 00 so 4990 GreerraigLaiie ••. .•.•• I . cosco San Dieg4CA 92123 "..• I Fire Protection (858) 444-2000 far 444-2056 CALic.: C46 #577621 www.cosafire.com MATERIAL SUBMITTAL Date: 04/11/17 Cross Country Mortgage LI 5901 Priestly Dr. suite 302 Carlsbad, CA 92008 JOB # 10.CD_5747 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. FPC20I7-0136 5901 PRIESTLY DR Submitted by: Felipe Alvarez UNIT302 Los Angeles 0 San Francisco • Orange • Fresno • San Diego • Seattle December 4, 2013 Sprinkler 51a MICROFAST® AND MicrofastHP® QUICK sI I F(I Fi1G'i RESPONSE UPRIGHT AND CON VENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHPO Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design require- ments. The special Polyester, Polytetrafluoroethylerie (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984B-PDA VdS VdS Approved: Certificates G4060054, G4060056, G4880046, G4930039, and G4980020 LPC Approved: Ref. No. 096e103, TE30401, and TE30872 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, 0786-CPD-40171, and 0786-CPD-40278 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1 008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart I and Design Criteria on pages 51c-d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 51e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Viking Technical Data may be found on Available since 1987. The Viking Corporation's Web site at Minimum Operating Pressure: 7 psi (0.5 bar)* http://www.vikinggroupinc.com. Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for The Web site may include a more recent use with water working pressures ranging from the minimum 7 psi (0.5 edition of this Technical Data Page. bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the de- flector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12978, 06766B, 07060, and 12281. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12978, 067648, and 12281. Copper UNS-C19500 for Sprinklers 06665B, 07060, and 14817. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Form No. F080488 Replaces page 51a-e, dated. June 28, 2013. - (Changed 06931 toVK3271) Sprinkler 51b Dmber4, 2013 MICROFASPAND MicrofastHP® QUICK l:llE..7'w RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsv1ingcorp.com Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the apLpriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part numba Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N, EI11= JN Temperature Suffix (°F/°C): 135°/57" = A, 155°/68° = B, 175°/79° = D, 200°I93° = E, and 2860/1410 = G For example, sprinkler VK300 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 2978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasingthe pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a unifm spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The 'liking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a niork of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Vikir! Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES _ Ordinary 135 F(57 C) 100 F(38 C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 "C) 150 °F (65 °C) Green High 286 °F (141 "C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratingsexcept 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority l-ving Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 5tc-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatirgs are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior arfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the watiay is coated. December 4, 2013 Sprinkler 51c MICROFAST® AND TECHNICAL___________ MicrofastHP® QUICK iII(I11G ® RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com I I I pprova Base Part Thread Size I Nominal K-Factor Overall Length Listings and A Is, I SIN I I (Refer also to Design Criteria on page 51d.) Number' I I NPT BSP I U.S. I metric' Inches I mm cULus4 I NYC- I VdS I LPCB CET 0 Upright -Standard Orifice 12978 I VK300 I 1/2" 15 mm I 5.6 I 80.6 2-3/16 I 56 I Al, B4 ISee Footnote 7 I -- I -- I -- I -- 07060 VK345 -- I 15 mm 5.6 I 80.6 2-3/16 56 -- I -- I A2 A2 B212 I B2 Conventional-Standard Orifice 06766B I VK310 I 1/2" 15 mm 5.6 I 80.6 1 2-3/16 I 56 A2 A2 -- I A2 I B212 I B215 Upright -Large Orifice 06665B [ VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B4 1 Al A2 1 A2 B212 14817 I VK350 -- 20mm 8.0 115.2 2-5/16 59 Al,B4 I Al A2 1_A2 B212 06764B16 VK350 1/2" 15mm 8.0 115.2 2-5/16 59 Al,B4 ] Al A2 ] -- A213 Conventional-Large Orifice 06768B [vK354 3/4" 20 mm 8.0 115.2 1 2-5/16 1 59 Al A2 -- ] A2 B212 Upright-Small_Orifice' 06717B11 I VK325 1 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Al -- -- 067191311 F VK327 1 1/2" 15 mm 4.2 57 2-3/16 56 Al Al -- -- -- 06931B11 VK3271 -- 10 mm 4.2 57 2-3/16 56 -- -- A2 -- C314 Maximum 250 PSI (17 bar) WWP Upright-Standard Orifice Base Part SIN Thread Size Nominal K-Factor Overall Length Listing and Approval83 s also to Design Criteria on page _(Refer ________________________________ 51d.) Number' NPT I BSP U.S. I metric' Inches I mm cULus4 I NYC9 I VdS I LPCB I 12281 VK315 1/2" 15 mm 5.6 80.6 2-3/16 I 56 Al Al -- -- -- I -- Upright-Small Orifice16 1228611 I VK340 I 1/2" I 15 mm 2.8 40.3 1 2-3/16 56 I Al I Al -- -- I -- I -- Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and - Brass, Chrome, White Polyester5'6, Black Polyester' '6, and 286 °F (141°C) Black PTFE5 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2- Brass, Chrome, White Polyester5'6, and Black Polyester5'6 C-155°F(68°C) 3 - Brass and Chrome 4-ENT' Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Methc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. Meets New York City requirements, effective July 1, 2008. 8Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 9Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. IS Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40278. 14 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 15 • MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-108. "The 1/2 NPT Large Orifice Sprinkler is Listed and Approved for retrofit only Sprinkler 51d December 4, 2013 MICROFASTAND MicrofastHP® QUICK NIKJNG4 RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvkingcorp.com cULus Listing Requirements: Microfase and MicrofastHP® Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard whft'e allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional iprinklers, refer to the installation guidelines for old style (conventional) sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be instIed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, aid standards, whenever applicable. Protective SprinRlEr Wrench Flat Co.P 10896 Figure 1: Standard Sprinkler Wrench 10896W1B December 4, 2013 Sprinkler 51e MICROFAST® AND MicrofastHP® QUICK 'si I FI ItI® RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Base Part Thread Size Nomi Overall Length FM Approvals3 !17met7riej SIN Number' NPT BSP US.nches mm (Refer also to Design Criteria below.) Standard Orifice 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A2, B3 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 A2 Large Orifice 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 A2, B3 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A2, B3 06764B7 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 A2, B3 Small_Orifice4 __________________________________ 0671766 VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Approved Finishes Approved Temperature Ratings 1 - Brass and Chrome A- 135 °F (57 °C), 155°F (68 °C), 175°F (79 °C), 200 °F (93 °C), and 286°F (141°C) 2 - Brass, Chrome, White Polyester5, and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyester5 3 - ENT8 Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response Non-Storage pendent sprinklers. For specific application and installation requirements, reference the latest appli- cable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Approvals as the standard colors. The sprinkler orifice is bushed. 7The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only 8 FM approved as corrosion resistant. FM Amroval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-Storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_080488 Replaces page 51a-e, datedJune 28, 2013. (Changed 06131 toVK3271) December 4, 2013 Sprinkler 41a MICROFAST'AND A MicrofastHP® QUICK 'J I KI I1J RESPONSE PENDENT SPRINKLES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvlingcorp.com DESCRIPTION Viking Microfast5 and MicrofastHPO Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In ad- dition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resist- ant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and 64980021 LPC Approved: Ref. Nos. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0786-CPD-40130, 0786-CPD-40170and 0786-CPD- 40279, 0832-CPD-2001, and 0832-CPD-2003 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart I and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's b site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http://www.vikinggroupk.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include amore recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Oita Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressurelor LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12979 and 12282. Brass UNS-C84400 for all otter sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 12979, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C 19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT coated. Form No. F 081296 Replaces page 41a-f, dated June 28, 2013. - (Changed 069B to VK3311.) AEEEEERL Wrench Flat Protect Spriaki Shietc Protective Sprinkler Cap 1: r= 10896 (D Sprinkler 41b December 4, 2013 MICROFAST'AND "si 11(1 I1Gu l:II[u.YIv MicrofastHP® QUICK RESPONSE PENDENT SPRINKLES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsv1ingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Microfase and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, and ENT= JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, and 286 °F(141 °C) = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B* (available since 2011) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) *A 'A" ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to BLietin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a unifmn spray pattern to extinguish or control the fire. I INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance require- ments. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench1O896WJB I December 4, 2013 Sprinkler 41 c MICROFASTAND MicrofastHPO QUICK RESPONSE PENDENT SPRINKLES The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 "F (57 "C) 100 "F (38 "C) ' Orange Ordinary 155 "F (68 °C) 100 °F (38 "C) Red Intermediate 175 "F (79 "C) 150 "F (65 "C) Yellow Intermediate 200 °F (93 °C) 150 "F (65 "C) Green High 286 "F (141 "C) 225 "F (107 "C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratingsexcept 135 "F (57 "C). Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority HMng Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Apprl Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the watings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposedexterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers the waterway is coated. H_ - Sprinkler Wrench 16036W/B*w for installing recessed pendent sprinklers *A 1/2' ratchet is required (not available from Viking). Carefully slide the wrench sideways around the protective cap, ensuring engage- ment with the sprinkler wrench flats. Sprinkler 41 d December 4, 2013 MICROFASPAND MicrofastHP®QUICK N I1(1 fjJ RESPONSE PENDENT SPRINKLES The Viking Corporation, 210 N Industrial Park Drive, Hastings Mi 49058 Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metric2 Inches mm cULus4 NYC5 VdS LPCB I Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 AiX, B1Y, C4, E4Z AiX, B1Y -- -- - -- 18021 VK302 1/2" 15 mm 56 80.6 2-1/4" 58 A% B1Y AiX, B1Y A2 A2X, 132Y C2X,Y11 C2X, E2Y14 Large Orifice 06666B VK352 3/4" 20 mm 80 115.2 2-3/8" 60 AiX, 131Y, C4, E4Z AiX, 131Y A2 A2X C2- 067651311 VK352 1/2" 15 mm 80 115.2 2-3/8" 60 AiX, B1Y, C4, E4Z AiX, 131Y A2 -- AF -- Small Orifice' 06718139 VK329 1/2" 15 mm 2.8 40.3 2-3116" 56 AiX, B1Y AiX, B1Y -- -- - -- 06720B9 VK331 1/2" 15 mm 4.2 57 2-1/4" 58 AiX, BiY AiX, B1Y -- -- - -- 06932B VK3311 -- 10 mm 42 57 2-3/8" 60 -- -- A2 -- G313 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Nominal Overall Listings and Approvals3 Base SIN Thread Size K-Factor Length (Refer also to Design Criteria on page 41a.) Part No' U.S. metric2 Inches mm cULus4 NYC'- VdS LPCB 12282 VK317 [~15 5.6 80.6 2-1/4" 58 AiX, B1Y AiX -- -- - -- Maximum 250 PSI (17 bar) WWP Small Orifice9 1228010 1 VK342 1 1/2" 115 mm 2.8 1 40.3 2-3/16" 56 AiX, B1Y AiX -- -- - -- Approved Temperature Ratings Approved Esctheons A - 135 OF (57 CC), 155 OF (68 "C), 175 OF (79 "C), 200 OF (93 "C), and Approved Finishes X - Standard surface-mored escutcheon or 1 - Brass, Chrome, White Polyester 6'7, Black P t1 the Viking Microfasdel F-i Adjustable B 135 F C), F C), 175 F(79 C), 200 F C) - (57 155 (68 and (93 Polyester6'7, and Black PTFE6 Escutcheon C - 155 OF (68 C), 175 F (79 C), 200 F (93 C), and 286 F (141 2 - Brass, Chrome, White Polyester7, and Black Y - Standard surface-moiMed escutcheon or C) Polyester7 the Viking Microfast sdeI F-i Adjustable D - 135 OF (57 "C), 155 OF (68 "C), 175 OF (79 "C), and 286 OF (141 - Brass an, , rome Escutcheon or recess with the Viking "C) Micromatic' Model E-1 E-2, or E-3 Recessed E - 155 "F (68 "C), 175 "F (79 "C), and 200 "F (93 "C) ENT6 Escutcheon F - 155 OF (68 "C), 175 OF (79 "C), and 286 OF (141 "C) Z - Standard surface-mounted escutcheon or re- G - 155 OF (68 "C) cessed with the Viking romatic® Model E-i Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 6 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized The sprinkler orifice is bushed. 10Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. " CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40279. 13 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 14 MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1 003 and 0832-MED-1008. 15 The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. December 4, 2013 Sprinkler 41e MICROFAST®AND 'IIIII1G l:ll[.q•.yM MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vlkngcorp.com cULus Listing Requirements: Microfastw and MicrofastHPw Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation .accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be insted in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16' (58,7 mm) minimum 2-1/8' 2-1/2' (63.5 mm) maximum (54 ) 1/2' (15 mm) il( NPT -1/4' 8 mm) (41 mm) Pendent Sprinkler f 1-3/4' ______ (44. mm) Installed with a standard 1/8' surface- mounted escutcheon, - LUlLII. 11 all ' I _ Maximum L Installed with a Microfast Model F-i Adjustable Escutcheon W Note' At maximum, adapter is exposed 1/2' (12.7 mm) from face of ceiling. Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8" Ceiling Opening Size: 2-1/8" (54 mm) 2-5/16" (58,7 mm) minimum (54 mm) 2-1/2" (63,5 mm) maximum (4, Installed with a Micromatic Model E-1 Recessed Escutcheon 2" 1-1/8" (28,6 rim) (50.8 mm) Minimum Maximum _______ Installed with a thread on Model E-2 Recessed Escutcheon mm) Sprinkler 41f Dmber4, 2013 MICROFASPAND MicrofastHP®QUICK '1 11(1 I1G® RESPONSE PENDENT SPRINKLES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs'vkingcorp.com Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 A2X, 132Y, C3,111113Z 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A2X, B2Y Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 A2X, B2Y, C3,03Z 06765B7 VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A2X, 132Y, 03,11113Z Small Orifice4 06718136 VK329 1 1/2' 15 mm 2.8 40.3 2-3/16" 1 56 AiX Approved Temperature Ratings Approved Escutchs A - 135 "F (57 °C), 155 °F (68 °C), 175 °F (79 °C), X - Standard surface-mounted escueon or the Viking 200 "F (93 °C), and 286 "F (141 °C) Approved Finishes Microfast Model F-i Adjustable Escutcheon B - 135 °F (57 "C), 155 °F (68 "C), 175 "F (79 "C), 1 - Brass and Chrome Y - Standard surface-mounted amitcheon or the and 200 °F (93 °C) 2 - Brass, Chrome, White Polyesters, and Viking Microfast Model F-i Acable Escutcheon C- 155 °F (68 °C), 175 °F (79 °C), 200 "F (93 °C), Black Polyesters or recessed with the Viking Miciinatic® Model E-i, and 286 °F (141 °C) 3 - ENT' E-2, or E-3 Recessed Escutchi D - 155 "F (68 °C), 175 °F (79 "C), and 200 "F Z - Standard surface-mounted esceon or recessed (93 C) with the Viking Micromatic® Mo E-1 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factoithown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional apprLs. "FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation reqLments, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. The sprinkler orifice is bushed. The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. FM approved as corrosion resistant. FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklersas indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Dat.Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water sily requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceilint NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. tSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer tatechnical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pageQR1-3 for gen- eral care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with tie latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similaorganizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated June 28, 2013. (Changed 069B toVK3311.) FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in mm' [in ii mm mm [ptj[ kg/] CRR [ Lift 1% 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 i[9OO 48.3 1.682 42.7 09 E2.7T1 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 21 J 2.875 f 730 2.635 11 669 1T20 L 305 353 526 35 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46' 2.6 19 4 r4.500 1 114.3 4.260 11 108.2 - 3.05 .120 5.62 8.37! - 1.6 19 L. .. .. .. . 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6J 6 625 1683 6387 161 5 134 340 930 1 13 8 10 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 'Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category WY. The CRR is ratio value used to measure the ability of a pipe to withstand corrosion Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES j mm[][m j[ In mm E]I kg/mi CRRI Lift ] 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1 1660 422 1380 351 IT4o 356 227 33911100 111 51 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.051 1.00 44 375 6031 2.067 525 [154 391 366 100 L 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category The CRR is ratio value used to measure the ability of a pipe to withstand corrosion Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C@ APPROVED PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYJE: LOCATIONS: COMMENTS: D BLACK HOT-DIP GALVANIZED Wheatland Tube 700 South Dock Street Sharon, PA 16146 i t• wi'i P 800.257.8182 1 F 724.346.7260 1 info@wheatland.com I wheatland.com Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line B3183) Size Range: 3/4" (20mm) thru 2" (50mm) CPVC pipe Material: Pie-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" 2< 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pie-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Max. Hanger Fastener Hex Arox. Pipe Size A B C Spacing Head Size VLt100 Part No. in. (mm) in. (mm( in. (mm) in. (mm) Ft. (ml in. (mm) Lk (kg) L 24./4 3k'(20) 25/16" (58.7) 1/32' (27.8) 13/16(30.2) 51/2 (7) /i6"(79) 9 ( 24-1 1 (25) 2/8' (66.7) 1/16" (33.3) 1/16" (30.2) 6 (1.83) /16' (7.9) 914.1) [ 24-l'I4 11/4" (32) 3" (76.2) 11/2" (38.1) 13/16" (30.2) 61/2 (1.98) /16' (7.9) 11(5.0) 24-11I2 11/2' (40) 31/4" (82.5) 1/8" (42.3) 1/16" (30.2) 7 (2.13) /16' (7.9) 11(5.4) J4-2 2" (50) 311/16" (93.7) 127/32" 1/16" (30.2) 8 (2.44) /16" (7.9) 1L (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4' (20mm) thru 2" (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" (20mm) thru 2' (40mm). Patent #5,344,108 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwia specified. 38 Fire Proteon Solutions Beam Clamps Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65X1 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: VOW Fig. 65 - 1/2"_13 rod sizes, and I8'-1 1 rod sizes Fig. 65XT - 3/8'-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /8'-16 rod will support 1/2" 115mm1 thru 4" )loomm) pipe 1/2'..13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65-/2 1/2"13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-I8 /8"-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) 65.1I2 11/4" (31.7) 55 (24.9) ] 65-/8 11/4" (31.7) 55 (24.9) Set Screw and Locknut Included FL 1. >1 51 'USTEfl p I8 2l Fig. 65X1-3/8 - Beam Clamp Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Finish: Plain or Electro-Galvanized Order By: Figure number and finish (19.01 Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" (100mm) pipe. Set Screw and Locknut Included Designed to meet or exceed requirements of FM DS 2-0. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. BLiflè Fire Protection Solutions 13 by ET4N Locknut Included All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 14 Fire Protection Solutions B-Line Beam Clamps Fig. 66 - Reversible Steel C-Type Beam Clamp 11/4" (31.7mm) Throat Opening 6T0 LM Size Range: /8'-16, 1/2'13 rod sizes, and 5/'-11 rod sizes Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 11/4' (31.7mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /8'-16 rod will support 1/2" (15mm) thru 4" (1 00mm) pipe 1/2"..13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 66-/e /8"-16 1/16" 130.21 11/4" (317) 1" (25.4) /16" (11.1) 66-1/2 1/2"13 11/2" (38.1) 11/4" (31.7) 1" (25.4) /16" (14.3) [i 5/e /811-11 11/2" 138.1) 11/4" (31.7) 1" (25.4) /16" (14.3) Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) 66-3/8 1.' (25.4) 28 (12.7) 66-1/2 11/4" (31.7) 55 (24.9) 1/4" (31.7) * -- 55 (24.9) Beam Clamps Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: I8'-16 & 1/2 l3 rod 4" (101,6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore the beveled locking slot of the Fig. 69R will provide a secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Finish: Pre-Galvanized Order By: Figure number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) For Use With: Any B-Line or TOLCO beam clamp. * Patent #5,947,424 Slot Width Length Part No. in. (mm) 6811.7 '(30i)SpeJ 69R-1/2-L /16" (30.1) Specify TCLccr Component of State of - California OSHPD Approved Seismic Restraints System Lima A-A All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 17 B-Linè by E*fe'$j All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 86 Fire Protection Solutions BLiflè by Ft.Nt' Upper Attachments Fig. 75 - Swivel Attachment Size Range: - /8'-16 Rod Attachment Material: Steel Function: Recommended applications for this product: May be used as a Branch Line Restraint for structural attachment to anchor bolt, beam clamp, etc. May be used in a pitched or sloped roof application, to meet requirements of NFPA 13 (2010) 9.1.2.6. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support up to 4" (lOOmm) pipe. Finish: Electra-Galvanized Weight: Approx. Wt./1 00 - 13.3 Lbs. 16.Okgl Order By: Figure number Patent: #7,887,248 C Fig. 78 All Steel Ceiling Plate Fig. 75 Swivel Attachment Fig. 2GO All Threaded Rod Adjustable Band Hanger Fig. 25 Surge Restrainer May be used as a structural attachment component of a branch line restraint - -- Fig. 65XT Reverte Beam Clamp W-Beam ); Fig. 75 Swivel - - -- - Attachment All Threaded Th d Rod May be used with a pitched roof application, to meet requirements of NFPA 13 (2010) Sec. 9.1.2.5. A Thread Size Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B32051 - Threaded Rod (right & left hand threads) Size Range: /8'16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish - - Standard Design Load Thread Size Thread Length TL 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) [ B3205-3/s x 1 3/8 -16 21/2' (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x '/2-13 21/2' (63.5) 1350 (6.00) 1057 (4.70) [ B3205-5/ex 5/8 -11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 1 B3205-3/4 x L /4"-l0 3' (16.2) 3230 (14.31) 2530 (11.25) B3205-1/8 x L /8"-9 31/2' (88.9) 4480 (19.93) 3508 (15.60) 1 For larger sizes consult full line pipe hanger catalog ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8'-16 thru 11/2"-6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. Threads Recommended Load Approx. Wt./100 Ft. & Size Per Inch Lbs. (kN) Lbs. (kg) AIR 'IC x 1' 20 240 (1.07) 12 (5.44) J ATR 3/C x'1' 16 730 (3.24) - 29 (13.15) LRThI2_xl 13 35o 53 (24O4) AIR /8' x'1' 11 2160 (9.60) 89 (40.37) . 3Ll. 1 AIR /8" x'1' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. - All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Me by ff.ilr41V *. 94 Fire Protection Solutions Fig. 200-I to 200-2 Fig. Z-21/2 to 200-8 Fig. 200F Pipe Hangers Fig. 200 - Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pie-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F )343°C) Finish: Pie-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Pipe Size Rod Size A B Approx. Wtj100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) L200-1I2 1/"(m) ft"-l6 3W')79A) 25Lt' (663) 11(5.OL_J 200-I4 3/4' (20) /8"-16 31/8" (79.4) 21/2' (63.5) 11 (5.0) [ 200-1 1" (25) I8"-16 3/8(85.7)2/8'(66.7) 12(5.5) ] 200-11/4 11/4" (32) /8"-16 33/4' (94.0) 2/8' (73.0) 13 (5.9) I 200-11/2 11/2" (40) - /8"-16 3/8" (98.4) 2/8' (73.0) 14 ()_ 200-2 2" (50) /8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) [i-2'I2 21/2° (65) /8"-16 55/8"(142)41/8"l104M 27 (123) 200-3 (75) /811-16 5/8' (149.1) 4' (101.6) 29 (13.3) I 200-3V2 31/2' (90) - 3/811-16 73/8'(187.3)51/4'(133 6)T 200-4 (100) /8"-16 7/8' (187.3) (127.0) 35 (16.0) [200-5 5"_(125)_ 1/2"13 91/8" (231.8) 61/4°(158.1) 66 200-6 6" (150) 1/2"_13 101/8" (257.2) 6/4' (171.4) 13 (33.4) 200-8 8' (200) 1/2"713 --13-1/8"(33-34) 8/4" (222.2) 136 (62.3) Fig. 200S Al) dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. V V Fire Protection Solutions B1ine21 by'E'1,N' Installs into Metal Deck, Purlin, or Tubular Steel DESCRIPTION/SUGGESTED SPECIFICATIONS Sammy X-Press Revolutionizes The Pipe Handing Trades— The Sammy X-Press® System is designed to provide direct attachment of threaded rod in ml deck (22-16 gauge) and thin gauge purlin (18-16 gauge), while providing reduced installation cons in terms of time and materials. The X-Press Anchors eliminate the need for costly "armovers" in pipehanging installations. Current methods offered for thin gauge purlin require use of a time-consuming retaining nut on the threaded portion of the fastener toprevent pullout and are not designed for use in metal deck. lnmany instances, access to the backside of the installed fastenis prohibited by panel liner or roofing insulation. Sammy X-Press® anchors deliver the performance installers require without the use of a retaining nut! I Sammy X-Press the patent-pending X-Press Anchors consist a threaded - fastener and expandable sleeve. The X-PressSystem features an easy-to-install anchor with expanding anchoring strips that collapse to prevent pullout after installation. The Sammy X-Press' It Installation Tool assures a perfect installation every time offering the a&d convenience of one-tool efficiency —just drill and drive in seconds! SECONDS! ADVANTAGES D Installs in seconds, saving time & m Less jobsite material needed. installation costs. No retaining nut required. Use in applications where access to the back of Provides design flexibility. the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Sammy's X-Press, Swivel and Sidewinder The Sammy X-Press expanto provide direct vertical attachment in: - Metal Deck (22-16 gauge) Patent No. 6,935,821 - Z-Purlin (18-16 gauge) t The Sammy X-Press Swivdallows you to hang plumb in extreme roofpitches: - 89° in 7-Purlin Patent Pending 450 in metal deck for 12/1Z pitch The Sammy X-Press Sidewinder expands xf to provide horizontal attachment in: patentpending \, - 16 ga - 3/16' steel - purIirtubuIar steel. Rooc pnclttS [512 SAMMYS ITg, bistnjction Products (all our toll free number 800-381-9692 or visit www.itwco9structiza for general information. Visit ITW Buildex'sSAMMYS web site www.sammvnuDencrew.com for the most current prndiuland technical information. UXPIT Patent Pending I PART NUMBER MODEL DESCRIPION EACH QTY 94910 UXPIT Universal X-Press Itbol 1 8152910 XPDB 25/64" Drill Bit 1 iMPJ1I. 2. Attach Sleeve. Sammy X-Press Sprinkler Systems Pipes/Plumbing Electrical Lighting and Fixtures HVAC Equipment and Fixutres The X-Press System has earned the 9R21 and ISES UL Listing. SAMMY X-PRESS ir INSTALLATION IDOL To watch a video demonstration of the SammyX-Press, visit http://wwwsammysuperscrew.com/sammyxpress.htm *Tool Includes: Sleeve, Bit Receiver, Flex Wrench, and /64" Drill Bit, ITW ConsUuctionPmduc Call our toll free number 800-387-9692 or sins www.itwconstnjction.ca for general information. Visit 13W Builder's SAMM VS web site www.rammnsuperscrew.com for the most current product and technical information. SAMb1YS S13 [ROD PART 1 F"' ULTIMATE MODEL DESCRIPTION I PULLOUT TEST LOAD ' TEST I LOAD MAXMIN B (AS! APPLICATION SIZE NUMBER us THICK THICK QTY QTI (LBS) LISTED (LBS) (LBS) Sidewinder 1250 (31h' Pipe) 8293957 SWXP35 1798 (16 ga) 80 (Luminaire) .060" .125" 25 125 Purlin X-Press 35 (Conduit& Cable) SAMMYS X-Press Horizon tal Mount Sammy X-Press SELECTION CHART ROD PART ULTIMATE SIZE NUMBER MODEL DESCRIPTION PULLOUT - - (LBS) 1/4' 8181922 - XP 200 X-Press 200 (22 ga) 6,935,821 1146 T 3/8" 8150922 XP 20 X-Press 20 1146 (22 ga) F3/8'8153922 XP35 X-Press35 1783 (16ga) L) TEST LOAD M TEST <> LOAD MIN MAX BOX CM! APPLICATION us LISTED (LBS) (LBS) THICK THICK QTY QTY 185 (Luminaire) .027" 125 25 125 Metal Deck 250 (Luminaire) 056 850 (21/2" Pipe) 940 (2" Pipe) .027" 185 (Luminaire) 250 (Luminaire) 1475 (4" Pipe) .027" .125" 25 125 Metal Deck 283 (Conduit& Cable) .056" 1250 (3½" Pipe) .060" 85 (Luminaire) 940 (2"I.105" 250 (Luminaire) 1475 (4".027,125 25 125 Purlin 416 (Conduit & Cable) .056" Metal Deck 3/8" 8150922 XP 20 Sammy 1146 (22 gal 850 (2½ Pipe) Pre-Pour Structural Concrete@ 3000 psi 25 125 (Pre-Pour) X-Press 20 Post-Pour Range)) LWC:5 35 PCF (lbs/f3) Metal Deck (Post-Pour) Pre- Pour Structural concrete @3000 psi Post-Pour Range II 11C:05 PG (lbs/OS') 77. 7 -_~ Epp ii J,n8 ParnoPendOg EvOgEME lialif pings ROD PART MODEL DESCRIPTION ULTIMATE PULLOUT QUS LOAD TEST TEST MIN MAX BOX CLIV APPLICATION SIZE NUMBER THICK THICK QTY QI! (LBS) LISTED (LBS) (LBS) 750 (2" Pipe) 170 vertical (Luminaire) Swivel 1061 (22 ga Vertical) 80 @ 45° (Luminaire) 3/8" 8294922 SXP 20 X-Press20 829 (45° Off Vertical) 283 vertical 635 (2" Pipe) .027" .125" 25 15 Metal Deck (Conduit & (able) 233 @45° (Conduit & Cable) 1500(4" Pipe) 250 vertical (Luminaire) Swivel 1675 (16 ga Vertical) 80 @90° (Luminaire) 3/8" 8295922 SXP35 X-Press 1558 189° Off Vertical) 500 vertical 635 (2" Pipe) .060" .125" 25 11 Purlin (Conduit & Cable) 333@89° (Conduit & Cable) 1/2° 8272957 SXP2.0 Swivel 1061 (22 ga Vertical) .027" .125" 25 IA Metal Deck X-Press2.0 829 (45° Off Vertical) 1/2" 8271957 SXP3.5 Swivel 1675 (16 ga Vertical) .060" .125" 25 IA Purlin X-Press3.5 1558 (89° Off Vertical) L 514 SAMMYS ,Tw iistnjciion Products (all our toll free number 800-387-9692 or visit www utwconstnicthisa for general information. Visit lTW8uildWsSAMMY5 web site www.sammmu8efscrew.com for the most current prodaod tmhnical information. SXP 20 AND SXP 35 FOR 3/8" ROD Structural attachment for installation of branch/end of line restraint using 3/8 all thread (.299" OD) or end thread rod (.374" OD). SXP 20 for 3/8" Rod: Designed for use in metal deck ranging from 22 ga. through 18 ga. in low slope or pitched roof designs (12/12). SXP 35 for 3/8' Rod: Designed for use in steel purlin ranging from 16 ga. through 1/8' in low slope or pitched roof designs (12/12). The Swivels may be used to attach short length of rod to eliminate lateral sway bracing per NFPA 13, 9.3.5.3.8, (2007). SXP 2.0 AND SXP 3.5 FOR 1/2" ROD . Structural attachment for installation of branch/end of line restraint using 1/2" all thread (.405" OD) or end thread rod (.500" OD), SXP 2.0 for 1/2" Rod: Designed for use in metal deck ranging from 22 ga. through 18 ga. in low slope or pitched roof designs (12/12). SXP 3.5 for 1/2" Rod: Designed for use in steel purlin ranging from 16 ga. through 1/8" in low slope or pitched roof designs (12/12). The Swivels may be used to attach short length of rod to eliminate lateral sway bracing per NFPA 13, 9.3.5.3.8, (2007). FEATURES O Structural attachment and restraint component combined; ready for selected rod. C Access to the back of fastener not required. C Does not require use of a C Aesthetkally pleasing. retaining nut. C Quick and easy installation. RE IREAII SPECIFICATION Bon% DEW t\th tceoRtV. FOR 3/8" ROD AND 1/2" ROD t. Restrained Pipe Size: Up to Schedule 40 pipe 2" or less Max Length of Restraint Material: See Maximum Horizontal LoadTables below. Maximum Angle: 45° from horizontal Material: Carbon Steel Screw Description: 1/4-20 x 1-1/8' with expandable sleeve Finish: Electro-Zinc Testing: Tested to GR-63-CORE Standaidlor performance in structural steel in seismic restraint applications as outlinedkr use in NFPA 13(2007), 9.3 at an independent test lab. The calculated force used fthe testing was equal to that found in a Zone 4 and an 8.4 Richter scale seismic evet. Listing for 3/8" Rod: UL 203 listed as pipe hanger File EX 5098 - SXP 20 (22 ga.) 0-45° from horizontal -2" Schedule 40 pipe - SXP 35 (16 ga.) 0-90° from horizontal - 3-1 /2"Schedule 40 pipe •L UL 203A File EX 15565 ®us LISTED LISTED Listing for 1/2" Rod: UL 203A File EX 15565 BENEFITS C Reducedinstallation cost. C Design ihibility. C Less onte material (GO GREEN). Less merial coordination. SELECT-IONr CHART i ROD I PART I MODEL MIN MAX I I APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER I THICKNESS THICKNESS _________ QTY QTY 3/8" I 8294922 SXP 20 22 ga I 18 ga. I Metal Deck 25 125 1/2" I 8272957 I SXP 2.0 22 ga I 18 ga. I Metal Deck 1 SWXP 35 must be installed 3/8" 8295922 I SXP 35 I 16 ga I 1/8" I Purlin 25 125 h WIT Tool (Part No. 8194910); pre-drilling required. 1/2" I 8271957 SXP 3.5 16 ga t-,"/81, I Purlin Restraint Shape and Size Nominal Diameter Area (in .2) Least Radius of Gyration, r (in.) hr = 100 Rods (all thread) 3/8 in. 0.07 0.075 0.6 1/2 in. 0.129 0.101 0.8 Rods (threaded at ends only) 3/8 in. 0.11 0.094 0.8 1/2 in. 1 0.196 0.125 1 1.0 Reference: NFPA 13, (2007) Reference: NFPA 13, (2010) ITW Construction Products Call our toll free number 800387.9692 on visit wwwjtwconsmictiops.ca for general information. Visit ITW Buildex's 5,4 MM I'S web site www.sammyouisaew.com for the most current product and technical information. Maximum Rod LenØfor hr (ft) I/r=200 Ih=300 I/r=400* 1.3 1.9 2.5 1.7 2.5 3.4 1.6 2.4 3.1 2.1 3.1 4.2 SAMA'IYS° 515 SAMMYS X-Press for Seismic Restraint SWXP 35 FOR 3/8" ROD Structural attachment for installation of branch/end of line restraint using 3/8" threaded rod. Used primarily in purlin, bar joist, or other steel structural members. These fastening systems provide a secure and economical attachment to the structure. The SWXP 35 model provides upper structural attachment in a range of steel thicknesses, from 16 ga. through 1/8". An expandable sleeve is included with each fastener, eliminating need for retaining nut. Restrained Pipe Size: Up to Schedule 40 pipe 2" or less Max Length of Restraint Material: See Maximum Horizontal Load Tables below. Maximum Angle: 45° from horizontal Material: Carbon Steel Screw Description: 1/4"-20 X 1-1/8" with expandable sleeve Finish: Electro-Zinc (cap & screw) Testing: BX Report# R-1362 Listing: UI. 203 as a pipe hanger UL UL 203A pending LISTED 7177sw MIN MAX APPLICATIONMODEL BOX CASE INSTALLATION TOOL THICKNESS THICKNESS QTY QTY The SWXP 35 mtbe installed XP 35 16 ga. 1/8' Steel Purlin or Bar Joist 25 125 with WIT Tool (Part No. 8194910); pre-drilling requil. Iliusol d I Maximum Rod Length for l/rtft) Restraint Shape and Size Nominal Diameter Area (in.2), r (in.) hr = 100 = 200 hr = 300 hr = 400* 3/8 in. 0.07 0.075 0.6 1 1.3 1.9 2.5 Rods (all thread) t 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 3/8 in. 0.11 0.094 0.8 t 1.6 2.4 3.1 Rods (threaded at ends only) 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Reference: NFPA 13, (2007) * Reference: NFPA 13, (2010) L S16 SAMMYS ,Tw DiUuction Products (all our toll free number 800387-9692 or visit wwwAtwcorisUueti.cu for general information. Visit ITW Buildex'oSAMMYS web site www.sammysupencrew.com for the most current prodialand technical information. FireLock Outlet-T STYLE 922 For Complete Information Request Publication 10.52 Incorporates 1/2-1'/10-25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products UL/ULC Listed, LPCB, VdS/FM Approved for branch connections on wet and dry systems Style 922 FireLock Outlet-Ts are not approved for cross configurations Pressure rated up to 300 psi/2065kPa and rated up to 230 psi/16 Bar at the ambient temperatures typical for fire protection systems Sizes from PA x ½"/32x 15 mm through 2½x 1/76.1 x25 mm Hole Cut Piping System Hole Approx. Size !flSIIIIII uJl,mlnhr.10. Vgt. Each Run x Branch Inches +0.06/+1.5 Inches Inches Inches Inches Inches Lbs. 56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 -0.45 3/~ 1 ~6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 ½ 13A6 1.42 1.95 1.22 4.08 2.56 1.2 40 > 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 15~ 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 19~ 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 ½ 15~ 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 1 65.0 0.59 3/~ 13A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30,2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 1.88 2.54 1.46 4.60 2.56 1.5 25 1 30.2 1 47.8 64.5 37.1 116.8 65.0 0.68 21/2 ½ 19~ 1 1.91 2.44 1.71 5.40 2.56 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 -0.73 3/4 1 1.89 2.44 1.71 5.40 2,56 1.6 20 30.2 48.0 62.0 434 137.2 65.0 0.73 1 1996 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 1h 13/16 1.91 2.44 1.71 5.50 2.56 1.6 761 mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0,73 3/4 1996 1.89 2,44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139,7 1 65.0 0,73 1 1 2.13 2.79 1.71 5.50 1 2.56 1.7 25 30.2 54.1 70,9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) malt pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitabiTi in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). Mill4 MM A MI TYPICAL FOR ALL SIZES 59 \J'tauIic WWW.VICTAULIC.COM G-105 FIRE PROTECTION CATALOG Mechanical-I® STYLES 920 AND 920N STYLES 920 AND 920N STYLEO CROSS PATENTED Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder° locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify Choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature rar€e plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in acrdance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/-i-82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral ads within the specified temperature range. Not recommended for hot water services over +150°T/.i-66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that thee are services for which these gaskets are not recommended. Reference should always bemade to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chen*a1 requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect ____________ Para__________ Location Date Approved www.victaulic.com VICTAi.JLiC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2010 vIcTAtJLIc COMPANY. ALL RIGHTS RESERVED. RE V_K jctauIicr 11.02_i DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size Dime-ions :~ght Each Inches +0.13 Inches Inches Inches Inches Inches Inches L, S. Lbs. 2 ½)a)a 5.35 275 31 ON '150 x j5 50 3450 38,1 51 64 70 ~ (a) 920¼ 500 1.50 1.97 2.53 1.61 5.35 2.75 81 20 3450 38.1 50 64 41 136 70 15 1 (a) 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 30 25 47 64 41 136 70 1.4 1 1/4 (a) 'l'a 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 35 3.2 32 3450 44.5 52 70 76 1 41 136 76 57 1.5 1½ (a) t a 920¼ 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 36 3.2 40 3450 44.5 52 70 79 41 136 1 83 1.7 1.5 2 x 1/2 (a) §n 920¼ 500 1.50 2.21 2.74 91.82 5.64 2.75 10 65 15 3450 38.1 56 70 - 46 143 70 - 14 IK )a( 920¼ 500 1.50 2.18 2.74 1.82 5.64 2.75 30 20 3450 38.1 55 70 46 143 70 - 14 1(a) 920¼ 500 1.50 2.06 2.74 1.82 5.64 2.75 29 25 3450 38.1 52 70 46 143 70 14 114 t(a)a 500 1J5 2.30 3.00 3.25 1.82 6.29 3.00 35 3.2 32 920N 3450 44.5 58 76 83 46 160 76 1.7 1.5 1112 t (a) a 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 36 3.3 40 3450 50.8 58 76 83 46 159 83 Il 1.6 76.1 < ½(a) 0N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 is 2065 38.1 56 70 - 57 164 81 - 1.8 3/4 (a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 39 20 2065 38.1 1 56 70 57 164 81 18 1(a) 920N 300 1.50 2.07 2.75 2.25 6,46 3.18 . SB - 25 2065 .- Il 1¼ (a) a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 35 3.2 32 3450 44.5 58 76 84 49 160 76 16 1.5 1½ (a) a 920¼ 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 35 3.3 40 3450 50.8 58 76 84 49 160 83 16 1.5 3 x 1/2 (a) a 500 1.50 2.52 3.05 2.28 6.15 2.75 1.4 80 15 0N3450 38.1 1 64 78 1 1 58 156 70 16 3/4 (a) a 920¼ 500 1.50 2.49 3.05 2.28 6.15 2.75 34 20 3450 38.1 63 78 58 156 70 18 - 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2,75 33 25 3450 38.1 61 78 58 156 70 16 1¼ (a) to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 32 3.7 32(b) 0 44.5 65 83 90 58 156 Th 18 1.8 1 ½ (a) to 920¼ 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 41 3.8 40(b) 0 50.8 n 89 90 58 156 83 0 1.8 2 (a) a 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 49 4.6 50 .3450 63.5 70 89 90 58 172 99 1.3 2.1 3½ X 2 92 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 90 50 3450 63.5 - 76 95 62 171 99 1.8 TABLE CONTINUED INUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on oider. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. Vds approved for fire protection services a -PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 REVK DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 Fri m through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections, CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N St, le M- Work Approx. Size No. Pressure@ Dimensions Weight Each Inch es or psi +0 ' 13 Inches Inches Inches Inches Inches inches Los. L, S. mm 920N kPa -0.00 mm mm mm mm man mm kg kg TABLE CONTINUED FROM PAGE 2 920½ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 100 15 3450 38.1 77 90 68 178 70 1.8 3A (a) u 920½ 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 1.8 1(a) 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 73 1.8 - lit (a) to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 10 36 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1h (a) to920N 500 2.00 3.28 4.00 4.00 169 701 125 42 39 40(b) 3450 50.8 83 102 102 1 68 1 178 83 2.0 1.9 2 (a) ' 920½ 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 2½ (a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 761 mm 920 500 2.75 188 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 - 102 68 186 118 - 2.9 3 (a) t 920 500 3.50 3.31 4.50 4.12 2.69 773 512 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 1080 x 1/. (a( a 920N 500 1.75 3.08 3.78 2.63 7,64 3.05 5.0 32 3450 44.5 78 96 67 194 78 2.3 - 1 1/2 )a( 0 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 67 194 83 2.3 - 2 (a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 63.5 83 102 67 194 102 19 - 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 78 3450 69.9 73 102 102 67 194 109 3.6 3.5 3(a) 920 500 3.50 3,31 4,50 4.50 2.63 763 4.88 6.8 6.5 80 3450 88,9 84 114 114 67 194 124 3.1 3.0 1½ (a) 1 920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 1.4 7.6 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a) t 920 500 2.50 4.00 4.75 4.75 3.16 170 4.38 8.2 8.0 50 3450 1 63.5 102 121 121 80 246 111 3.7 3.6 2½ (a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 79 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm u 920 500 2.75 3.75 4.75 3.16 9.70 4.63 - 8.0 3450 69.9 95 1 121 80 246 118 - 3.6 3 (a)t 920 500 3.50 3.81 5.00 4.63 3.16 920 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 1330 x 2 920½ 500 2.50 3.75 4.50 3.17 8.00 188 8.0 50 3450 63.5 95 114 - 81 203 99 3.6 - 920 500 3.50 3.81 5.00 3.00 9.46 531 8.0 80 3450 88.9 97 127 76 240 135 3.6 - TABLE CONTINUED ON PG. 4 Lenter or run to engaged pipe end, temale threaded outlet only (dimensions approximate t Available with grooved or female threaded outlet. Specify choice on order, * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT' clearly onorder. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victauljc.com ictaul- VIcTAULIc IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2010 vICTAULIC COMPANY. ALL RIGHTS RESERVED. ______________ REV_K 11.02_3 DIMENSIONS GROOVED OUTLET I lip 9 "N III FEMALE THREADED OUTLET IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2'750 x 15 mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size Dimensions Inches +013 Inches Inches Inches Inches Inches Inch(g. TABLE CONTINUED FROM PAGE 3 19 n1m -0.00 mm mm mm mm Trun mmE 1 ½ t 139.7 x 920¼ 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 114 84 209 83 3.2 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 - 84 209 99 4.1 - 6 1¼ (a) < 920 N 500 1.75 4.43 513 513 3.79 9.15 3.25 5.1 4.8 150 32(b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 1½ (a) to 20N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 1 130 1 96 232 1 83 2.4 1 2.3 2(a) fo 920¼ 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 76.1 mm 920 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 - 132 94 267 118 - 3.8 . 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 1 ½(a) 159.0 x 920N 500 2.00 4,41 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 - 92 239 83 3.5 - 2(a) 920¼ 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 - 50 3450 63.5 111 130 - 92 239 99 3.6 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 92 239 155 - 4.5 4 920 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 114.3 96.80 146 - 92 239 159 8.2 TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet, Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services e LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com 'Ltauiic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vIcTAuLIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 REV _K DIMENSIONS GROOVED OUTLET siI 04 * awmME FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½/SO x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Work M Size Run x Branch Nominal Size I psi Inches mm kPa ,cq' ax. CONTINUED FROM PAGE 4 1651 )< 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 116 96 237 70 3.6 1 A a 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130. - 96 237 83 3.8 - 1½ (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2 (a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm ° 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 699 1 110 130 132 92 267 118 39 3.4 (a) 1 0 920 500 3.50 1 4.31 5.50 523 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4 Ia) 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2(a) t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 316 114 5.3 5.3 2½ (a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 1 122 316 114 1 53 53 76.1 mm 9 0 500 2.75 5.25 6.25 4.81 12.42 4.56 3450 69.9 133 159 122 316 116 3 (a) tO 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 6.25 [E5 80 3450- 88.9 135 165 165 122 316 135 4 (a) 920 500 4.50 4.81 6.75 6.38 4.81 12.42 100 3450 114.3 122 171 162 122 316 159 center or run to engagea pipe end, Female threaded outlet only (dimensions approximate t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com \,#'tauI_____________jc VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. _ REV_K 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical—I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalT® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/-i-16°C are shown in the table below. Formulas for C 1Ky Values: AP = Q2 Where: AP = Where: Q = Flow (GPM) K Q = Flow (m3/h) Q = C x AP = Pressure Drop (psi) C = Flow Coefficient AP = Pressure Drop (bar) Q = K X JAP K = Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Sc hedule 40 Carbon Steel Pipe OUTLET I NOMINAL ACTUAL DIAMETER 0. D. InImm Inlrnrn GROOVED THREADED GROOVED THREADED 1/2 I 0.840 11 15 21.3 - 2 - 9.4 3/4 1.050 - 16 20 267 - 13.7 1 1.315 21 - 8 25 33.7 - 1.8 iv4 1.660 50 48 32 42.7 6 42.9 41.1 1 1/2 1.900 11 53 53 40 98.3 45.4 45.4 2 2.375 112 104 50 60.3 9 10 /2 96 89.1 2½ 2.875 119 150 65 73.0 20 12½ 102 128.5 3.000 161 76.1 mm 16 - - 76.1 138.1 3.500 249 237 80 88.9 14 151/2 213.4 203.1 4.500 421 401 100 114.3 20 22 360.8 1 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165ini4.2mm. www.victaulic.com VIcTAULIc IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2010 VICTAIILIC COMPANY. ALL RIGHTS RESERVED. 11.02_6 REV_K CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subct to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and apprals. Run Nominal Inches/mm Actual Siz~ Di mete, Inchestrum Outlet Size Approval ItI:#.l,.,j1. Agency Vds outside Siz : 21/2 - 6 .875 - 6.625 Inches/mm Schedule All 1040 LIL 400 LILC 400 FM 400 LPCB (Style 920) ',Style 920N) 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875 - 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875 - 4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 300 300 250 290 232 362 150 168.3 10 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 1 0,40 400 - - - 145 200 219.1 2755 1000 8 8.625 3,4 10 300 - 250 145 - 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 - 300 - 145 - 200 219.1 2065 2065 1 11000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 87100 - 200MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/345OkPa, The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted 0n4"/100mm, 57125mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 21/2'i5mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com \11taUIjc vicrAuuc IS REGISTERED TRADEMARK OF VICTALJLIC COMPANY. © 2010 ViCTALIC COMPANY. ALL RIGHTS RESERVED. REV_K 11.02_7 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products ID be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 148O REV K UPDATED 4/2D10 ictaulico VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_K