Loading...
HomeMy WebLinkAbout5901 PRIESTLY DR; 301; FPC2017-0113; PermitI ir1 PIll i sfl (Jiity of Carlsbad Print Date: 12/06/2024 Job Address: 5901 PRIESTLY DR, # 301, CARLSBAD, CA 92008-8825 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: CENTERPOINT SUITE 301- SPRINKLER TI 7-100 HEADS (41) Applicant: COSCO FIRE PROTECTION MATT JORGENSEN 4990 GREENCRAIG LN SAN DIEGO, CA 92123-1673 (858) 444-2000 FEE Permit No: FPC2017-0113 Status: Closed - Finaled Applied: 05/05/2017 Issued: 05/31/2017 Finaled Close Out: 04/05/2021 Final Inspection: INSPECTOR: Stowe, Daniel FPContractor: COSCO FIRE PROTECTION INC 1075 W LAMBERT RD BREA, CA 92821-2944 (858) 444-2000 AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov San Diego Branch Office .00000 .. 4990 Greencraig Lane 00 cosco San Diego, CA 92123 ::::: • Protectionre (858) 444-2000 fax: 444-2056 CA Lie.: C-16#577621 www.coscofire.com MATERIAL SUBMITTAL Date: 5/5/2017 Centerpoi*nt Suite 301 5901 Priestly Dr. Suite 301 Carlsbad, CA 92008 JOB #1O.CA 5747 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. FPC20I7-0113 5901 Priestly DR UN1T301 Submitted by: Felipe Alvarez Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle December 4, 2013 Sprinkler 51a MICROFAST® AND MicrofastHP® QUICK I 1(1 t1G® RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHPO Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design require- ments. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-F, Volume 16 ABS Certified: Certificate 04-HS407984B-PDA VdS VdS Approved: Certificates G4060054, G4060056, G4880046, G4930039, and G4980020 LPC Approved: Ref. No. 096e/03, TE30401, and TE30872 CE Certified: Standard EN 12259-1 EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, 0786-CPD-40171, and 0786-CPD-40278 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on pages 51c-d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 51e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Viking Technical Data may be found on Available since 1987. The Viking Corporation's Web site at Minimum Operating Pressure: 7 psi (0.5 bar)* http://www.vikinggroupinc.com. Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for The Web site may include a more recent use with water working pressures ranging from the minimum 7 psi (0.5 edition of this Technical Data Page. bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the de- flector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12978, 06766B, 07060, and 12281. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12978, 06764B, and 12281. Copper UNS-C19500 for Sprinklers 06665B, 07060, and 14817. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Form No. F 080488 Replaces page 51a-e, dated June 28, 2013. - (Changed 06931 to VK3271) Sprinkler 51b December 4, 2013 MICROFAST® AND MicrofastHP® QUICK N I Kj RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sorinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N, ENT = JN Temperature Suffix (°F/"C): 135"/57" = A, 155"/68° = B, 175°/79" = D, 200°/93° = E, and 286"/141" = G For example, sprinkler VK300 with a 1/2" thread, Brass finish and a 155 "Ff68 "C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5.., OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES ir Ordinary 135 "F (57 °C) 100 "F (38 "C) Orange Ordinary 155 °F (68 "C) 100 "F (38 °C) Red Intermediate 175 "F (79 "C) 150 "F (65 "C) Yellow Intermediate 200 °F (93 "C) 150 "F (65 "C) Green High 286 "F (141 "C) 225 °F (107 "C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 "F (57 "C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51 c-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. December 4, 2013 Sprinkler 51c MICROFAST® AND MicrofastHP® QUICK 44JkJ RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com I I Base Part I Thread Size Nominal K-Factor Overall Length Listings and Approvals3 SIN I (Refer also to Design Criteria on page 51d.) I I I Number' I I NPT I BSP I U.S. I metric2 Inches I mm cULus4 I NYC- I VdS I LPCB I CE I Upright -Standard Orifice 12978 I VK300 I 1/2" I 15 mm I 5.6 I 80.6 2-3/16 I 56 I Al, B4 See Footnote 7.1 I -- 07060 I VK345 -- 15 mm 5.6 80.6 2-3/16 56 -- I -- A2 A2 B212 I B2 Conventional-Standard Orifice 06766B I VK310 I 1/2" I 15 mm 5.6 I 80.6 1 2-3/16 I 56 I A2 I A2 I -- I A2 B212 I B215 Upright -Large Orifice 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B4 Al F A2 A2 1 B2'2 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B4 Al F A2 A2 I B212 06764B16 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, B4 Al A2 -- j A213 Conventional-Large Orifice 06768B VK354 3/4" 20 mm 8.0 115.2 1 2-5/16 1 59 1 Al A2 -- A2 J B2'2 Upright-Small_Orifice1' 0671713" VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Al F -- -- -- 06719131' VK327 1/2" 15 mm 4.2 57 2-3/16 56 Al Al F -- -- -- 06931 B11 VK3271 -- 10 mm 4.2 57 2-3/16 56 -- -- A2 -- C314 Maximum 250 PSI (17 bar) WWP Upright-Standard Orifice Base Part SIN Thread Size _ Nominal K-Factor _ Overall Length _ s Listing and Approvals3 (Refer also to Design Criteria on page __________ 51d.)__ Number' NPT I BSP U.S. I metric2 Inches I mm cULus4 I NYC' I VdS LPCB CE 1 • 12281 VK315 1/2" I 15 mm 5.6 I 80.6 2-3/16 56 Al Al [ -- -- -- Upright-Small Orifice10 1228611 1 VK340 I 1/2" I 15 mm T 2.8 I 40.3 1 2-3/16 56 Al I Al -- Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155°F (68 "C), 175°F (79 °C), 200°F (93 "C), and - Brass, Chrome, White Polyester5'6, Black Polyester5'6, and 286 "F (141°C) Black PTFE5 B - 155 "F (68 "C), 175 "F (79 "C), 200 °F (93 "C), and 286 °F (141°C) 2- Brass, Chrome, White Polyester',', and Black Polyester5'6 C - 155 °F (68 "C) 3 - Brass and Chrome 4 - ENT Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. Wien pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. °cULus Listed as corrosion resistant ° Other colors are available on request with the same Listings and Approvals as the standard colors. Meets New York City requirements, effective July 1, 2008. °Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. °Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. 0 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40278. 14 CECertified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 15 • MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. 16 The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only Sprinkler 51d December 4, 2013 MICROFAST® AND MicrofastHP® QUICK "ill lI(IIIG® RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com cULus Listing Requirements: Microfast® and MicrofastHP11 Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler FL Wrenchch Protective Cep e :=1089E =(D) Figure 1: Standard Sprinkler Wrench 10896W113 December 4, 2013 Sprinkler 51e MICROFAST® AND MicrofastHP® QUICK NiKING4 RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' NPT BSP U.S. I metric2 Inches mm (Refer also to Design Criteria below.) Standard Orifice 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A2, B3 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 A2 Large Orifice 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 A2, B3 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A2, B3 06764B7 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 A2, B3 Small_Orifice4 0671786 VK325 1/2" 15 mm 2.8 40.3 1 2-3/16 56 Al Approved Finishes Approved Temperature Ratings i - Brass and Chrome A- 135 °F (57 °C), 155°F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286°F (141°C) 2 - Brass, Chrome, White Polyester5, and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyester' 3 - ENT" Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response Non-Storage pendent sprinklers. For specific application and installation requirements, reference the latest appli- cable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Approvals as the standard colors. 6 The sprinkler orifice is bushed. 'The 1/2' NPT Large Orifice Sprinkler is Listed and Approved for retrofit only 8 FM approved as corrosion resistant. FM Arnroval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-Storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_080488 Replaces page 51a-e, dated June 28, 2013. (Changed 06931 to VK3271) FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES TJT'1 mm in. _ 1Tn. IEI1 :1r'CRR. Lift] 11/4 1.660 42,2 '1.900 j 48.3 1 1.442 1.682 36.6 .109 2.77 427 J[iIj 2,77 1.81 2.09 2.69 7.3 61 3.11 5.8 61 2 2.375 60.3 - 1 2½_j[ 2,875 73.0 1 2.157 2.635 10 54.8 .109 2.77 66.9 [.1203.05 2.64 3.53 3.93 4.7 37 5.26 1 =30 3 3.500 88.9 =4F4 70.1 114=3 3.260 4.260 82.8 .120 3.05 108.2 .120 __3.05 1 4.34 1 5.62 6.46 2.6 1 19 8.37 IL_1.6 19 5 5.563 141.3 I 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 II_168.3 6.367 161.5 .1343.40] 9.30 13,85 =1 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in.1I_J[rJJ[mm_Ibs./ft.][k9/m [cRR'J Lift I 1 1.315 33.4 1.049 1 II 1 1.660 42.2 1.380 .133 3.38 .140 3.56 35.1 II_ 1.68 2.50 2.27 00 70 1t1.00 il 1 U/i 1.900 48.3 1.610 2.375 60.3 1 2.067 40.9 .145 3.68 52.5 1[±_1[_3.911_3.66 2.72 ' 4.05 __5.45 1.00 44 [1.0030 Calculated using Standard (II. CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C& < APPROVED I PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: LI BLACK HOT-DIP GALVANIZED Wheatland Tube 700 South Dock Street Sharon, PA 16146 1. P800.257.8182 1 F 724.346.7260 1 info@wheatIand.com I wheatland.com 1 ii. I11ThT L1j Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line B3183) Size Range: 3/4" (20mm) thru 2' (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4' x 1' tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. Part No. CPVC Pipe Size in. (mm) A in. (mm) B in. (mm) C in. (mm) Max. Hanger Spacing Ft. (m) Fastener Hex Head Size in. (mm) Approx. W000 Lbs. (kg) 24-/4 3/4' (20) 2/16" (58.7) 1/32" (27.8) 13/16 (30.2) 51/2 (1.67) /16" (7.9) 9 (4.1)] 24-1 1" (25) 2I8" (66.7) 1/16" (33.3) 1/16' (30.2) 6 (1.83) /16" (7.9) 9 (4.1) 24-1'I4 11/4 (32) 3' (76.2) 11/2 (38.1) 1/16' (30.2) 61/2 (1.98) /i' (7.9) 11 (5.0) I 24_11/2 11/2 1401 31/4 (82.5) 1/8' (42.3) 1/16" (30.2) 7 (2.13) /16" (7.9) 12 (5.4) I42 2' (50) 311/16' (93.7) 127/32 (43.6) 1/16" (30.2) 8 (2.44) /16" (7.9) 15 (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4 (20mm) thru 2' (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" (20mm) thru 2' (40mm). Patent #5,344,108 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. BL in' ne- byf1J 38 Fire Protection Solutions 3/ (19. Set Sc Locknui 1/8 (221) Beam Clamps Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65X1 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: 1ST$UL Fig. 65 - 1/2'..13 rod sizes, and 5/8"-11 rod sizes Fig. 65XT - I8'-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /'-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2'..13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Set Screw and Locknut Included Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mml 65.1/2 1/2"_13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-/8 I8"-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) [ 65-I2 11/4" (31.7) 55 (24.9) 1 65./8 11/4" (31.7) 55 (24.9) Fig. 65XT-3/ - Beam Clamp Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Finish: Plain or Electro-Galvanized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cUlus) and FM Approved (FM) for up to 4" (100mm) pipe. Designed to meet or exceed requirements of FM DS 2-0. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. .. -.., BLine Fire Protection Solutions , 13 Beam Clamps Fig. 66 - Reversible Steel C-Type Beam Clamp 11/4" (31.7mm) Throat Opening Size Range: /8'-16, 1/2'..13 rod sizes, and /8'-1 1 rod sizes Material: Steel with hardened cup point set screw and jam nut Function: Recommended Recommended for hanging from steel beam where flange thickness does not exceed 11/4" (31.7mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UI) and Canada (cUl). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /8'-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2'..13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Locknut Included Part Rod Size B C D F No. A in. (mm) in. (mm) in. (mm) in. (mm) 66-3/s /8"-16 1/16" (30.2) 11/4" (31.7) 1" (25.4) /16" 111.11 66-1/2 1/2"_13 11/2" (38.1) 11/4" (31.7) 1" (25.4) /16" (14.3) /8"-11 11/2" (38.1) 11/4" (31.7) 1" (25.4) /16" (14.3) Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) 66-3/8 1" (25.4) 28 (12.7) 66-1/2 11/4" (31.7) 55 (24.9) [5I8 11/4" (31.7) 55 (24.9) . Al) dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B4LIn•e 14 Fire Protection Solutions Component of State of ' California OSHPD Approved Seismic Restraints System A-A Slot Width Length Part No. in. (mm) I 6911-3/8-1. /16" (30.1) Sy_J 6911-1/2-1. /16" (30.1) Specify Beam Clamps Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: Ie°-16 & 1/2'..13 rod 4" (101,6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore the beveled locking slot of the Fig. 69R will provide a secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Finish: Pre-Galvanized Order By: Figure number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) For Use With: Any B-Line or TOLCO beam clamp. * Patent #5,947,424 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. . - e - BLin Fire Protection Solutions 17 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 86 Fire Protection Solutions Upper Attachments Fig. 15 - Swivel Attachment Size Range: - /8-16 Rod Attachment Material: Steel Function: Recommended applications for this product: May be used as a Branch Line Restraint for structural attachment to anchor bolt, beam clamp, etc. May be used in a pitched or sloped roof application, to meet requirements of NFPA 13 (2010) 9.1.2.6. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUl) to support up to 4' (100mm) pipe. Finish: Electro-Galvanized Weight: Approx. Wt./1 00 - 13.3 Lbs. (6.0kg) Order By: Figure number Patent: #7,887,248 --------------------- I Fin. 78 All Steel V Ceiling Plate M Fig. 75 Swivel Attachment Fig. 200 All Threaded Rod to Adjustable Band Hanger Fig. 25 Surge Restrainer May be used as a structural attachment component of a branch line restraint Fig. 65XT Reversible Beam Clamp W-Beam Fig. 75 Swivel - - -. Attachment All I Threaded Rod May be used with a pitched root application, to meet requirements of NFPA 13 (2010) Sec. 9.1.2.5. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 94 Fire Protection Solutions Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B32051 - Threaded Rod (right & left hand threads) Size Range: /8-16 thru 3-4 rod Material: Steel TI Function: Recommended for use as a hanger support in hanger assemblies. Specify length < Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) IL Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and A materials. Thread Size Order By: Figure number, rod size, length and finish 1000 Standard Design Load Thread Size Thread Length IL 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. )kN) B3205-3/a x 1 /8-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-112 X '1 1/f-13 21/2 (63.5) 1350 (6.00) 1057 (4.70) I B3205-518 x L i8"-11 21/2' (63.5) 2160 (9.61) 1692 (1.52) B3205-314x '1' /4'-10 3" (76.2) 3230 (14.37) 2530 (11.25) I 83205-718 x '1' /8-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: I8"-16 thru 11/2"-6 rod in 10' )3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. & Size Threads Per Inch Recommended Load Lbs. )kN) Approx. Wt./100 Ft. Lbs. (kg) 1 AIR 1/4" x 'U 20 240 (1.07) 12 (5.44) ATR /8" x 'U 16 730 13.241 29 (13.151 [ATR i/f x 'L' 13 1350 (6.00) 53 (24.04) 7 AIR /8" x 'L' 11 2160 (9.60) 89 (40.37) [AIR 3/4' x 'L' 10 3230 (14.37) 123 (55.79) 1 ATR /8" x'1' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog Fig. 200C - B 200-1/2. 200-/4 Fig. 200-I to 200-2 Fig. 200-21/2 to 200-8 Fig. 200 Fig. 200F Fig. 200S Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specificatiQns Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications \N\N-H-171 E & A-A-I 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Part No. Pipe Size in. (mm) Rod Size in. A (mm) in. B (mm) Approx. Wt./100 lbs. (kg) L2oo/2 1/2" (15) /o"-16 3V8' )19.4l 2/8" (66.71 11 (5.0) ] 200-/4 3/4" (20) /8'-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 1 200-1 1" (25) /8"-16 3/8" (85.7) 2/8° (66.7) 12 (5.5)........J 200-11I4 11/4° (32) /8"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) II200-11/2 11/2 (40) /s"-16 3/8° (98.4) 2/8' (73.0) 14 (6.4(___j 200-2 2' (50) /8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21I2 21/2' (65) /t"-16 5/8' (142.9) 41/8 (104.7) 27 (12.3)_J 200-3 3" (75) /8"-16 5/8' (149.1) 4" (101.6) 29 (13.3) I 20031/2 31/2' (90) /8-16 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7/8' (187.3) 5" (127.0) 35 (16.0) I 200-5 5" (125) 1/2"13 91/8 (231.8) 61/4" (158.7) 66 (30.2)__.J 200-6 6" (150) 1/2 .13 101/8" (257.2) 6/4' (171.4) 73 (33.4) 200-8 8" (200) V2"-13 131/8" (333.4) 8/4" (222.2) 136 (62.3) I All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 b B Line yE Installs into Metal Deck, Purlin, or Tubular Steel DESCRIPTION/SUGGESTED SPECIFICATIONS Sammy X-Press Revolutionizes The Pipe Handing Trades— The Sammy X-Press® System is designed to provide direct attachment of threaded rod in metal deck (22-16 gauge) and thin gauge purlin (18-16 gauge), while providing reduced installation costs in terms of time and materials. The X-Press Anchors eliminate the need for costly "armovers" in pipe hanging installations. Current methods offered for thin gauge purlin require use of a time-consuming retaining nut on the threaded portion of the fastener to prevent pullout and are not designed for use in metal deck. In many instances, access to the backside of the installed fastener is prohibited by panel liner or roofing insulation Sammy X Press® anchors deliver the performance installers require without the use of a retaining nut' Sammy X-Press The patent-pending X-Press Anchors consist of a threaded fastener and expandable sleeve. The X-Press System features an easy-to-install anchor with expanding anchoring strips that collapse to prevent pullout after installation. The Sammy X-Press® It Installation Tool assures a perfect installation every time offering the added convenience of one-tool efficiency - just drill and drive in seconds! SECONDS! Installs in seconds, saving time & U Less jobsite material needed. installation costs. U No retaining nut required. Use in applications where access to the back of U Provides design flexibility. the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Sammy's X-Press, Swivel and Sidewinder The Sammy X-Press expands to provide 1 direct vertical attachment in: - Metal Deck (22-16 gauge) Patent 6,935,821 -Z-Purlin (18-16 gauge) The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: (5WXP) I - 89° in L-Purlin Patent Pending - 450 in metal deck for 12/12 pitch The Sammy X-Press Sidewinder expands to provide horizontal attachment in: Patent Pending - 16 ga - 3/16 steel - purlin, tubular steel. ROOr PflC-MES 512 SAMMYS iTw Construction Pmducts (all our toll free number 800-387-9692 or visit wwwAtwcopnstniction.ca for general information. Visit 1W Buildex'oSAMMYS web site www.sanrm0511Dersaew.cunl for the most current product and technical information. 1. Pre-Drill. 2. Attach Sleeve. 3. Insert Anchor. 4. Install. To watch a video demonstration oftheSammyX-Press, visit http://wwwsammysuperscrewcom/sammyxpress.htm Sammy X-Press Sprinkler Systems Pipes/Plumbing Electrical Lighting and Fixtures HVAC Equipment and Fixutres The X-Press System has earned the 91121 and 25E5 UL Listing. SAMMY X-PRESS IT INSTALLATION TOOL Patent Pending PART NUMBER MODEL DESCRIPTION EACH QTY 8194910 uxpir" Universal X-PressltTool 1 8152910 XPDB 25/64" Drill Bit 1 "Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64" Drill Bit. IT7 Construction Produciis (all our roll free number 800-381-9692 or visit www.itwconstnscton.ca for general information. Visit 11W Buildexo IA MM VS web site www.sammysuDerraew.com fur the most current product and technical information. SAMMYS 513 SAMMYS X—Precs_Verticnl Mou it -ROD PART - MODEL DESCRIPTION ULTIMATE PULLOUT L TEST LOAD LOA MIN MAX BOX CASE APPLICATION SIZE NUMBER THICK THICK QTY QTY (LBS) LISTED (LBS) (LBS) 8181922 XP 200 X-Press 200 1146 185 (Luminaire) - .027' - .125" - 25 - 125 Metal Deck (22 ga) 250 (Luminaire) .056" 850 (2½" Pipe) 940 (2" Pipe) .027" 3/8 8150922 XP20 8 Press20 1146 (22 gal 185 (Luminaire) 250 (Luminaire) 1475 )4" Pipe) .027" .125" 25 125 Metal Deck 83(Conduit&Cable) .056" 1250 (3½" Pipe) .060" 3/8" 8153922 XP 35 X-Press 1783 85 (Luminaire) 940 (2" Pipe) .105" .125" 25 125 Purlin (16 gal 250 (Luminaire) 1475 (4"Pipe) .027" 416 (Conduit & Cable) .056" Metal Deck 3/8" 8150922 XP 20 Sammy X-Press 20 1146 (22 ga) 850 (2½ Pipe) Pre-Pour Structural Concrete@ 3000 psi Post-Pour Range II LWC~ 35 P(F (lbs/It3) 25 125 (Pre-Pour) Metal Deck I - - (Post-Pour) Sammy X—Press SELECTION CHART Pro-Pour Structural Concrete @3000 psi gr Post-Pour Range II LWC 35 PCF (IbsIft°) 77. _- 771 —1... —7 _~ 7- 7 - —- . _7 —1. 7—k 1W VA I7-7 1: f Tfrf A ROD PART MODEL DESCRIPTION ULTIMATE PULLOUT I TEST LOAD TEST MIN MAX BOX CASE APPLICATION SIZE NUMBER $ THICK THICK QTY QTY (LBS) LISTED (LBS) (LBS) 750 (2" Pipe) 170 vertical )Luminaire) SoP) 009 Pitent Pending 3/8" 8294922 SXP 20 Swivel X -Press 20 1061 (22 ga Vertical) 80 @45° (Luminaire) 283 vertical 635 (2"Pipe) .027" .125" 25 125 Metal Deck Off Vertical) 829(45° (Conduit & Cable) 233 @1 45° 8000 PaCKS (Conduit & Cable) 1500(4" Pipe) 250 vertical (Luminaire) Swivel 1675 (16 ga Vertical) 80 @90° (Luminaire) 3/8" 8295922 SXP3S X-Press 35 1558)89° Off Vertical) 500 vertical 635 (2" Pipe) .060" .125" 25 125 Puffin (Conduit & Cable) 333@89° (Conduit & Cable) 1/2" 8272957 SXP2.0 Swivel 1061 )22gaVertical) .027" .125" 25 125 Metal Deck X-Press 2.0 829 )450 Off Vertical) 1/2" 8271957 SXP3.5 Swivel 1675 (16 ga Vertical) .060" .125" 25 125 Purlin X-Press3.5 1558 (89* Off Vertical) ROD PART MODEL DESCRIPTION PULLOUT ULTIMATE TEST £ TEST' LOADI LI MIN MAX BOX CASE APPLICATION SIZE I NUMBER I us THICK THICK QTY QTY I (LBS) LISTED (LBS)I (LBS) Sidewinder 1250 (31/2" Pipe) 3/8" 8293957 SWXP 351 1798 (16 ga) 80 (Luminaire) .060" .125" 25 125 Puffin X-Press 35 416 (Conduit & Cable) I - ITftW Construction Products Call our toll free number 800-387-9692 or visit www.itwonstruction.ca for general information. 514 SAfV1I'VIY"S Visit ITW Osiides SAMMYS web site www.samrnysuDerscrewom for the most current product and technical information. SAMMYS X-Press Horizontal Mount Ii r FEATURES Structural attachment and restraint component combined; ready for selected rod. Access to the back of fastener not required. Does not require use of a • Aesthetically pleasing. retaining nut. E r a Quick and easy installation. . £ IRE MI 10 SPECIFICATI ON Sam .. sc CA SCRIE2 FOR 3/8" ROD AND 1/2" ROD E. & Restrained Pipe Size: Up to Schedule 40 pipe 2" or less Max Length of Restraint Material: See Maximum Horizontal Load Tables below. Maximum Angle: 45" from horizontal Material: Carbon Steel Screw Description: 1/4-20 x 1-1/8' with expandable sleeve Finish: Electro-Zinc Testing: Tested to GR-63-CORE Standard for performance in structural steel in seismic restraint applications as outlined for use in NFPA 13(2007), 9.3 at an independent test lab. The calculated force used for the testing was equal to that found in a Zone 4 and an 8.4 Richter scale seismic event. Listing for 3/8" Rod: UL 203 listed as pipe hanger File EX 5098 - SXP 20 (22 ga.) 0-45" from horizontal -2" Schedule 40 pipe - SXP 35 (16 ga.) 0-90" from horizontal - 3-1/2" Schedule 40 pipe - $ UL 203A File EX 15565 ®us Listing for 1/2" Rod: UL 203A File EX 15565 usTED SXP 20 AND SXP 35 FOR 3/8" ROD Structural attachment for installation of branch/end of line restraint using 3/8' all thread (.299" OD) or end thread rod (.374" OD). SXP 20 for 3/8" Rod: Designed for use in metal deck ranging from 22 ga. through 18 ga. in low slope or pitched roof designs (12/12). SXP 35 for 3/8" Rod: Designed for use in steel purlin ranging from 16 ga. through 1/8" in low slope or pitched roof designs (12/12). The Swivels may be used to attach short length of rod to eliminate lateral sway bracing per NFPA 13, 9.3.5.3.8, (2007). SXP 2.0 AND SXP 3.5 FOR 1/2" ROD Structural attachment for installation of branch/end of line restraint using 1/2" all thread (.405" OD) or end thread rod (.500" OD). SXP 2.0 for 1/2" Rod: Designed for use in metal deck ranging from 22 ga. through 18 ga. in low slope or pitched roof designs (12/12). SXP 3.5 for 1/2" Rod: Designed for use in steel purlin ranging from 16 ga. through 1/8" in low slope or pitched roof designs (12/12). The Swivels may be used to attach short length of rod to eliminate lateral sway bracing per NFPA 13, 9.3.5.3.8, (2007). BENEFITS Reduced installation cost. Design flexibility. Less on site material (GO GREEN). Less material coordination. SELECTIONrCHART ROD PART I MODEL I MIN MAX I APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER I THICKNESS THICKNESS _________________________________________________________________ QTY QTY 3/8" I 8294922 SXP 20 I 22 ga I 18 ga. Metal Deck 25 125 The SWXP 35 must be installed 1/2" I 8272957 SXP 2.0 22 ga I 18 ga. I Metal Deck 25 125 3/8" 8295922 SXP 35 I 16 ga I 1/8" I Purlin -:-- --- with WIT Tool (Part No. 81949101; pre-drilling required. 1/2" I 8271957 SXP 3.5 16 ga I 1/8" Purlin 25 125 Least Radius of Maximum Rod Length for hr (ft) ___________________________ __________________________ Restraint Shape and Size Nominal Diameter Area (in.') Gyration, r (in.) hr = 100 I hr = 200 hr = 300 hr = 400* 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 Rods (all thread) 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 Rods (threaded at ends only) 1/2 in. 0.196 0.125 1.0 I 2.1 3.1 I 4.2 Reference: NFPA 13, (2007) "Reference: NFPA 13, (2010) IT1W Construction Products Call our toll free number 800-387-9692 or Visit www.itwconstn,ctlon.ca for general information. Visit 11W Bsildexn SAMMYS web site www.sammyslsoersaew.cem for the most current product and technical information. SAMMYS 515] SAMMYS X-Press for Seismic Restraint DESCRIPTION (SIDEWINDER) SWXP 1.I FOR ROD Structural attachment for installation of branch/end of line restraint using 3/8" threaded rod. Used primarily in purlin, bar joist, or other steel structural members. These fastening systems provide a secure and economical attachment to the structure. The SWXP 35 model provides upper structural attachment in a range of steel thicknesses, from 16 ga. through 1/8". An expandable sleeve is included with each fastener, eliminating need for retaining nut. Restrained Pipe Size: Up to Schedule 40 pipe 2" or less Max Length of Restraint Material: See Maximum Horizontal Load Tables below. Maximum Angle: 45° from horizontal Material: Carbon Steel Screw Description: 1/4"-20 X 1-1/8" with expandable sleeve Finish: Electro-Zinc (cap & screw) Testing: BX Report # R-1362 Listing: UL 203 as a pipe hanger UL UL 203A pending USTED I ROD I SIZE I PART NUMBER MODEL MIN THICKNESS MAX THICKNESS I APPLICATION BOX QTY CASE QTY INSTALLATION TOOL I The SWXP 35 must be installed 3/8" I 8293957 SWXP 35 16 qa. 1/8' Steel Pudin or BanJoist 25 125 with WIT Tool (Pad No. 8194910); pre-drilling required. Restraint Shape and Size Nominal Diameter Least Radius of Area On.')Gyration, r (in.) Maximum Rod Length for hr (ft) l/r = 100 hr = 200 hr = 300 I hr = 400* 3/8 in. Rods (all thread) 1/2 in. 0.07 0.075 0.6 I 1.3 1.9 2.5 0.129 0.101 0.8 1.7 2.5 I 3.4 3/8 in. Rods (threaded at ends only) 1/2 in. 0.11 0.094 0.8 1.6 2.4 3.1 0.196 0.125 1.0 I 2.1 1 3.1 1 4.2 Reference: NFPA 13, (2007) ° Reference: NFPA 13, (2010) 1 516 SAMMYS ITUW Construction Products (all our toll free number 800387-9692 or unit www.itwconstnrctf mica for genera! information. Visit 11W Builder', SAMMYS web site www.sammysuDerscrew.com for the most current product and technical information. Hole Cut Piping System Incorporates 1/2-1710-25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products UL/ULC Listed, LPCB, VdS/FM Approved for branch connections on wet and dry systems Style 922 FireLock Outlet-Ts are not approved for cross configurations Pressure rated up to 300psi/2065kPa and rated up to 230 psi/16 Bar at the ambient temperatures typical for fire protection systems Sizes from P/4x½"I32x 15 mm through 21/2x1776.1x25mm Hole •• Diameter Run x Branch Female Pipe Threadst IJi,iIl.k1I.Iik Approx. Wgt. Each Nominal Size T Inches +0.061+1.5 Inches 1% ½ 11/rn 1.30 V Inches 1.83 1.10 Inches Inches 3.87 2.56 Lbs. 1.0 32 15 30.2 33.0 46.5 27,9 98.3 65.0 0.45 Y4 19~ 1.28 1.83 1.10 3.87 2.56 11 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 3/rn 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1 ½ 1/2 11/6 1.42 1.95 1.22 4.08 2.56 1.2 40 x 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3% 1 996 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1996 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 1 65.0 0.59 2 ½ 1 3A6 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/4 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 1 55.6 37.1 116.8 65.0 0.64 1 1146 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 ½ X 1/2 13A6 1.91 2.44 1.71 5.40 2.56 1.6 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/~ 1 3A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm x ½ 1996 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 31~ 13/rn 1.89 2.44 1.71 5.50 2.56 1.6 20 1 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1 1A6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 1 54.1 70.9 43.4 139.7 65.0 1 0.80 FireLock Outlet-T STYLE 922 For Complete Information Request Publication 10.52 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). jMile TYPICAL FOR ALL SIZES 5-9 \/'taUIiC WWW.VICTAULIC.COM G-105 FIRE PROTECTION CATALOG MechanicaIT® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-lap Il Mechanical-I unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date__________________________________ www.victaulic.com - - vIcTAULIc ISA REGISTERED TRADEMARK OF VICTALILIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. • ctaukc REV_K 11.02_1 DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size Dimensions ro App x' Weight EachN Inches mm 2 ½ (a) 920N 500 +0.13 Inches Inches -0.00 mm mol 1.50 2.00 2.53 Inches Inches Inches mol mm MIT, 1.61 5.35 Inches mm 2.75 Lbs. Lbs. kg kg 3,1 50 15 3450 38.1 51 64 - 41 136 70 - 1.5 ~ (a) a 920N 500 1.50 1.97 2,53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - 1(a) a 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 - 1¼ (a) to 920¼ 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44,5 52 70 76 41 136 76 1.7 1.5 ,a 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2 X 1/2 (a) 5a 920 N 500 1.50 2.21 2.74 91.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 - 46 143 70 1.4 - Y4 (a) §n 920 N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 1 70 1.4 - 1 (a) §n 20N 500 1.50 2.06 2.74 1.82 5,64 2.75 2.9 25 3450 38.1 52 70 - 46 143 70 1.4 - 1 ¼ t (a) a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1½ 'I (3) a 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 920N 3450 50.8 58 76 83 46 159 83 1.7 1.6 ½ (a) 76.1 X 920N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 - 57 164 181 1.8 3/~ (a) 920N 300 1.50 2.19 2,75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 - 57 164 81 1.8 - 1(a) 920N 300 1.50 2.07 2.75 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 - 57 164 81 1.7 - 1¼ (a) a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 ½ (a) a 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 x 1/2 (a) a 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 - " 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 - 58 156 70 1.6 - 1(a) 20N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 - 58 156 1 70 1.6 . - I ¼ (a) to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a) a 920¼ .500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 1 172 99 2.3 2.1 31/2 2 920N 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 90 50 340 63.5 76 - 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 aa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a -PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ,4tauuic. VICTAULICIS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 REV_K DIMENSIONS Iciffle KIM GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Size Appr x. Dimensions Weight Each Inches +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. olm -0.00 rnm rnm mm mm mm mm kg lig TABLE CONTINUED FROM PAGE 2 1/2 (a) a 920N 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 100 15 3450 38.1 77 90 - 68 178 70 1.8 - 3/~ (a) a 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 1.8 - 1 (a) a 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 36 25 3450 38.1 73 90 - 68 178 70 1.8 1.75 3.08 3.78 4.00 2.69 7.01 3.00 40 16 1 1/4 )a) to 920N 500 32 )b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 ½ (a) to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2 )a( to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 2½ (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 - 102 68 186 118 - 2.9 3 (a) t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 1080 X 1¼ (a)a 920N 500 1.75 3.08 3.78 2.63 7.64 3.05 10 32 3450 44.5 78 96 - 67 194 78 2.3 1 ½ (a)a 920N 500 2.00 3.28 4.00 2.63 7.64 125 5.0 40 3450 50.8 83 102 67 194 83 2.3 - 2 (a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 63.5 83 102 - 67 194 102 1.9 - 761 mm 920 500 2.75 2.88 4.00 4.00 263 7.64 4.29 8.0 78 3450 69.9 73 102 102 67 194 109 16 3.5 3 (a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 X 1½ (a) t 920 500 2.00 4.03 4.75 4.75 3.16 9,70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 1 246 94 3.4 3.4 2 (a) t 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 1 102 121 121 80 246 111 3.7 3.6 2½ (a)t 920 500 2,75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 1 121 80 246 118 3.8 3.6 761 mm a 920 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 3450 69.9 95 - 121 80 246 118 - 3.6 3 (a) t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 14 18 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 1330 x 2 920N 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 50 3450 63.5 95 114 - 81 203 99 3.6 - 920 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 . 3450 88.9 97 127 - 76 240 135 3.6 - TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings Cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT Clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVK Ar- -ta U -1i C r 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS III Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. TABLE CONTINUED FROM PAGE 3 1 ½ t 139.7 x 40 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 3450 50.8 96 114 - 84 209 83 3.2 - 2 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 84 209 99 4.1 - 6 lÀ(s) >< 920N 500 1.75 4.43 513 513 3.79 9.15 3.25 5.1 4.8 150 32(b) 3450 44.5 112 130 130 96 232 83 1½ (a) to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 1 96 232 83 2.4 2.3 2(a) to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 761 ram 920 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 - 132 94 267 118 - 3.8 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 1 110 140 1 130 94 1 267 1 135 4.5 1 3.8 4(a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 625 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 59.0 x1½ (a) 920N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 - 92 239 83 3.5 - 2 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 92 239 99 3.6 - 761 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 1080 mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 92 239 155 4.5 920 500 4.50 1 114.3 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 96.80 1 146 - 1 92 239 159 8.2 TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 JtauIic REV_K CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm Size Approx. Run x Branch Dimensions Weight Each Inches +0.13 Inches Inches Inches Inches Inches Inches Lbs Lbs. III; TABLE CONTINUED FROM PAGE 4 1651 x 920N 500 1.50 3.88 4.56 I I 9.34 2.75 8.0 25 3450 38.1 99 116 - 96 237 70 16 - 1 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 - 1½ (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2(a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 1 92 1 267 118 1 3.9 3.4 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 x 2(a)t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 so 3450 69.9 138 157 159 122 316 114 5.3 5.3 2½ (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 53 5.3 76.1 mm 0 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3450 699 133 - 159 122 316 116 - 5.3 3 )a) to 920 500 3.50 5.31 6.50 6.30 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4(a) to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 (enter of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com - VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED ictauluc REV_K 1I.02_5 FLOW DATA Exaggerated for clarity CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical—I® Bolted Branch Outlets STYLES 920 AND 920N Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalF® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C, and Ky Values Values for flow of water at +60°F/-i-16C are shown in the table below. Formulas for C5 1K, Values: AP = Where: AP = Q2 Where: C Q = Flow (GPM) K 0 = Flow (m3/h) AP Pressure Drop (psi) AP= Pressure Drop (bar) 0 =Cv x ç = Flow Coefficient 0 = K x K = Flow Coefficient Equivalent Length of Outlet Size Schedule I;IIL1i1 40 Carbon . 120)t FT Cv/Kv Values NOMINAL ACTUAL DIAMETER 0. D. In/mun In/mm GROOVED THREADED GROOVED THREADED 1/1 0.840 11 15 21.3 94 1/4 1.050 16 20 26.7 - 4 137 1 1.315 21 - 8 - 25 33.7 1.8 1 ¼ 1.660 50 48 32 42.7 5½ 6 42.9 41.1 1 ½ 1.900 53 53 40 98.3 45.4 45.4 2 2.375 112 104 50 603 9 10½ 96 891 2½ 2.875 119 150 65 730 20 121/2 102 1285 3.000 161 761 mm 16 - 761 1381 - 3.500 249 237 80 88.9 14 15½ 213.4 203.1 4.500 421 401 100 114.3 20 22 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. www.victaulic.com _,4tauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_6 REV _K CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size wI Inches/mrn Nomi Size Diameter Outlet Size Pipe Approval Rated Workin g Pressures Agency — psi/kPa Vds 21/2 - 6 Inc .875 - 6.625 Inci All Schedule 10,40 UL 400 ui I 400 400 920) 290 (Style 920N) 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875 -4.500 All OF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875 -4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 - - - 145 - 200 219.1 2755 1000 8 8.625 3,4 10 300 - 250 - 145 - 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 300 - 145 - 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DE refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 8"/100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 5/125mm, 6/150mm and 8/200 mm diameter pipe. The Style 931 comes with a 2½765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com _14'ctauiic. vIcTAuLIc IS A REGISTERED TRADEMARK OF VICTALILIC COMPANY. Or 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED, REV_K 11.027 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV K UPDATED 412010 ictaulic VICTAIJLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_K