5901 PRIESTLY DR; 180; FPC2019-0029; Permit
PERMIT REPORT Caty of Carlsbad Print Date: 12/06/2024 Permit No: FPC2019-0029 Job Address: 5901 PRIESTLY DR, # 180, CARLSBAD, CA 92008-8825 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel 4*: 2120610300 Track 4*: Applied: 02/19/2019 Valuation: $90,787.52 Lot U: Issued: 03/04/2019 Occupancy Group: Project 4*: Finaled Close Out: 04/05/2021 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Fieri, Dominic Plan Check 4*: Project Title: Description: SPEC SUITE 180 -ALARM SYSTEM TI Applicant: RED HAWK FIRE AND SECURITY CA LLC ROBERT HASTINGS 920S ANDREASEN DR, 4* 102 ESCONDIDO, CA 92029-1936 (760) 233-9787 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov FACP Battery Calculations (Existing) 5901 Priestly Drive iO1000GD Fire Alarm Control Panel Description Quantity Standby (Amps) Total Standby (Amps) Alarm (Amps) Total Alarm (Amps) iO1000GD Base Panel 1 x 0.155000 - 0.155000 0.204000 0.204000 SA-DACT Internal Dialer 1 x 0.041000 0.041000 0.100000 0.100000 iO-SDC1 Single Loop Controller (Fully 1 x Loaded Loop) 0.055000 - 0.055000 0.125000 0.125000 GCF-VM, 15cd Strobe, Ceiling 6 x 0.000000 - 0.000000 0.063000 0.378000 G1F-HDVM, 15cd Horn Strobe, Wall 1 x 0.000000 - 0.000000 1 0.081000 0.081000 G1F-HDVM, 110cd Horn Strobe, Wall 2 x 0.000000 0.000000 0.203000 0.406000 0.000000 - 0.000000 0.000000 0.000000 Total: ..t 0.251000 1.294000 Battery Calculation ne_ Multiplier Amp Hours Supervisory Hours 24 x 0.251000 = 6.024000 Alarm Hours (5 Minutes) 0.083 x 1.294000 = 0.107402 Total Amp Hours = 6.131402 Battery Used (AH) = 18.000000 Battery Spare (AH) = 11.868598 FACP Battery Calculations (Revised) 5901 Priestly Drive iOl 000GD Fire Alarm Control Panel (With Added NAC Devices) Description - Quantity Standby (Amps) Total Standby (Amps) Alarm (Amps) Total Alarm (Amps) iO1000GD Base Panel I x 0.155000 0.155000 0.204000 0.204000 SA-DACT Internal Dialer 1 x 0.041000 0.041000 0.100000 0.100000 iO-SDC1 Single Loop Controller (Fully 1 x Loaded Loop) 0.055000 - 0.055000 0.125000 0.125000 GCF-VM, 15cd Strobe, Ceiling 6 x 0.000000 - 0.000000 0.063000 0.378000 G1F-HDVM, 15cd Horn Strobe, Wall 1 x 0.000000 - 0.000000 0.081000 0.081000 G1F-HDVM, 1 10c Horn Strobe, Wall 2 x 0.000000 - 0.000000 0.203000 1 0.406000 GCF-VM, 15cd Strobe, Ceiling 3 x 0.000000 - 0.000000 0.063000 0.189000 GCF-HDVM, 30cd Horn Strobe, Ceiling 2 x 0.000000 - 0.000000 0.101000 0.202000 X 0.000000 0.000000 0.000000 0.000000 Total: - - 0.251000 1.685000 Battery Calculation Time Multiplier - Amp Hours SuperAsory Hours 24 x 0.251000 = 6.024000 Alarm Hours (5 Minutes) Total Amp Hours 0.083 x 1.685000 = 0.139855 6.163855 Battery Used (AH) = 18.000000 . Battery Spare (AH) 11.836145 NOTE: THE MAXIMUM CHARGING CAPACITY OF THE 101000 FIRE ALARM CONTROL PANEL IS 26 AMP HOURS. TWO (2) 18 AMP HOUR BATTERIES ARE BEING SUPPLIED. THE BATTERIES ARE SEALED LEAD ACID, 12 VOLT, WIRED IN SERIES FOR 24 VOLT SYSTEM BACKUP. FACP BATTERY CALCULATION FIRE ALARM SYSTEM TENANT IMPROVEMENT SUBMITTAL For SPEC SUITE 180 CENTERPOINT PLAZA 5901 PRIESTLY DRIVE, SUITE 180, CARLSBAD, CALIFORNIA 92008 Submitted By: RED HAWK FIRE & SECURITY 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 0 Co DO) CD (Y D1 9 PROJECT INFORMATION SHEET PERMIT NUMBER: INSTALLING CONTRACTOR CONTRACTORS LICENSE PROJECT MANAGER: PROJECT NAME: PROJECT ADDRESS: RED HAWK FIRE & SECURITY 920 South Andreasen Drive, Suite 102, Escondido, California 92029 Phone: (760) 233-9787 C-10/C-16 #713099,11/30/20 John Stasukevich SPEC SUITE 180 Centerpoint Plaza 5901 Priestly Drive, Suite 180, Carlsbad, California 92008 SCOPE OF WORK: Fire Alarm System Tenant Improvement February 15, 2019 RE: Spec Suite 180 Centerpoint Plaza 5901 Priestly Drive, Suite 180, Carlsbad, CA 92008 Fire Alarm System - Tenant Improvement Red Hawk Fire & Security is pleased to submit the following equipment for your approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is sprinklered and monitored. QTY. MODEL NO. DESCRIPTION C.S.F.M. 1 BPS10A Remote Booster Power Supply 7300-1657:0229 3 GCF-VM Multi Candela, Strobe, Ceiling Mount 7125-1657:0219 2 GCF-HDVM Multi Candela, Horn/Strobe, Ceiling Mount 7125-1657:0202 Notes: 1. The new Remote Booster Power Supply is manufactured by EST and is compatible with all new devices. Respectfully submitted, RED HAWK FIRE & SECURITY * 7300-1657: 0229 IlEA 176-91-E vol.13 EDWARDS Ca)a)oq t> Power Suppits and Accessories 1UithIiie LIFE SAFETY INCIDENT MANAGEMENT Remote Booster Power Supplies BPS6A, BfS±O*' Overview The Booster Power Supply (BPS) is a UL 864, 9th Edition listed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification! Emergency Communication (MNEC), as well as life safety, security, and access control applications. The BPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the BPS can support batteries totaling up to 65 ampere-hours in an external enclosure. The BPS has four Class B (convertible to two Class A) NACs. These can be activated in one or two groups from the BPS's unique dual input circuits. The BPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The BPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 9th edition )uo)O(lFire Alarm systems UL636 (ANET, UEHX7) Holdup Alarm Units and Systems UL609 )AOTX, AOTX7) Local Burglar Alarm Units and Systems UL294 )ALW, UEHX7) Access control Systems UL365 (APAw, APAW7) Police Station Connected Burglar Alarm Units and Systems 01-1076 )APOU, APOU7) Proprietary Burglar Alarm System Units UL1610 )AMCX) Central Station Alarm Unit uLC-5527 )UO)O(C) Control Units, Fire Alarm (Canada) ULC-S303 )AOTX7) Local Burglar Alarm Units and Systems (Canada) C22.2 No. 205 Signaling Equipment (Canada) Standard Features Allows for rel able filtered and regulated power to be installed where needed Cost effec:ive sys:em expansion Provides for Genesis and Enhanced lntegrit notification ap- pliance synchronization Supports coded output operation Self-reStorrg ove-current protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board d agno.st c LEDs identify wiring or i-iternal faults Standard EDWARDS keyed lockable steel cEbinet with re- movable cocr 110 and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual batte-y charging rates Optional esthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Page lof4 DATA SHEET E850050125 t\bt to be used for inatallatioti purposes. Issue 1 D5 0 00I Top View D2-øI ft D3 0 81— D4 —*8 S S Front View > cl) 0 All knockouts for 3/4 in conduit (1.9 cm) Dl NMI ME CD CD CD Power-limited wiring area Application Dimensions The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations and can easily be installed where needed. Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the BPS can still be activated upon command. A separate AC Fail contact is available on the BPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. BPS NACs can be configured for a 3-3-3 temporal or continuous Dl D2 D3 D4 D5 D6 output. California temporal rate outputs are also available on cer- 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in tain models. This makes the BPS ideal for applications requiring (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) signaling rates that are not available from the main system. Engineering Specification Supply, where needed, EDWARDS BPS Series Booster Power Supplies (BPS) that are interconnected to and supervised by the main system. The BPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The BPS battery compliment shall be sized to match the require- ments of the main system. The BPS shall be capable of supervis- ing and charging batteries having the capacity of 24 ampere-hours for Mass Notification/Emergency Communication (MNEC), life safety and security applications, and the capacity of 65 ampere- hours for access control applications. <<The BPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The BPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- vided with automatically restoring overcurrent protection. The BPS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. BPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, California rate. Fault conditions on the BPS shall nbt impede operation of main sys- tem NAC. The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2of4 Notes 1. Maintain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL, FPLR, or FPLP cable per NEC. Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxiliary power. Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 In addition to the internally generated signal rates, the BPS can also be configured to follow the coded signal rate of the main Wire routing system NACs. This allows for the seamless expansion of existing NACs. The BPS enclosure has mounting brackets for up to three Signa- ture modules to the right of the circuit board. Route AC supply through these knockouts only (Nonpower-limited and supervised) Typical Wiring Single or cascaded booster NAC Circuit \ / > To next signaling device booster, booster, or NAC Circuit anywhere on a notification appliance circuit EOL re Existing NAC end-of-line resistors are not required to be Fire Alarm I ) NAC output #1 NAC output #2 installed at the booster's terminals. This allows multiple control Panel ) NAC Output #3 boosters to be driven from a single NAC circuit without the -D 0 ) NAC Output #4 need for special configurations. Booster Power Supply Configuring the Booster for Multiple CC1 (S) modules using the AC Power Fail delay operation* BPS's sense inputs TBI 0 Notification appliance circuit (NAC) 0 TBI Notification appliance circuit (NAC) NAC1/+ - UL listed UL listed AUX1 - - EOL 15kO NAC1I +J - AUX1 - - EOL 15 KW NAC2/ + AUX2 - Notification appliance circuit (NAC) NAC2/ +j AUX2 Notification appliance circuit (NAC) UL listed NAC3/ + - UL listed AUX3 - - EOL 15kO AUX3 - - NAC3/ + - 3z V EOL 15 KW NAC4/ + NAC4/ + AUX4 - AUX4 - 200 mAAUX o 200 mAAuX - Continuous - ___________ Continuous IN - IN Sense 1 COM - Sense 1 COM Ei - OUT E9311 - + OUT EOL 47 K IN EW 11011111 11 lNl± 109 Sense 2 COM EOL47 kO Sense 2COM ouiL E0L47 K OUT J CC1(S)m0du1ej NOE II 00 NO ______________ Trouble COM F 87 65 4 3 2 1 91 Trouble COM E IEJj] ___________________ NC I NC 109 I 109 —1.I-1+I-I TB2 LL7 TB2 CC1(S) module F CCI(S) module m J I Data out to CT1 II 8765 4321 0 00 0 876 pr ce :,__I next device ___________mouI[4]I __________ ______ Ti W+TWI -Ti--J or Signature I IvIct I 3 2 controller 1i ___ Data in from previous )i jJ *The Booster supports AC Data out to Power fail delay device or Signature of three hours via its trouble contact when next device controller dip switch Sw2-6 is on. All other troubles are reported to supervising module or panel without delay via Sense inputs. Security and access BPS 24 V I NAC1/ +_ =24DC12 I AUXI -- NAC2/ + I AUX2 -EJ NAC3/ AUX3 -LI1 NAC4/ AIIVA 12 V Security Security EOL device d e =vic e device To next device or end [1] Disable the BPS's ground fault jumper (JP3) Page 3 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 Specifications DS Model 6.5 amp Booster 1Bbtë? AC Line Voltage 120VAC or 220-240VAC 50/60Hz J 120VA0 or 220-240VAC 50/60Hz 390 watts I 580 watts LIFE SAFETY S INCIDENT MANAGEMENT Notification Appliance 3.OA max. per circuit @ 24Vdc 3.OA max. per circuit @ 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 10A max total all NACs Contact us... Trouble Relay 2 Amps @ 30Vdc Email: edwards.fire@fs.utc.com Auxiliary Outputs Four configurable outputs replace NACs 1 2, 3 or 4. as auxiliary Web: Edwards-fire.com outputs and 200 mA dedicated auxiliary. (See note 2.) Input Current 3mA @ 12Vdc, 6mA © 24Vdc EDWARDS is a UTC brand. (from an existing NAC) 1016 Corporate Park Drive Booster-Internal 0ZWA+ 35 mA for each circuit set to AUX Mebane, NC 27302 02016 United Technologies Corporation. Ot6QStëTdSl Alarm 270Th All rights reserved. Signature Mounting Accomodates three two-gang modules. Space Maximum Battery Size 10 Amp Hours (2 of 1 2V1OA) in cabinet up to 24 Amp hours with ex- ternal battery cabinet for fire and security applications; up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing © 32°C Temperature Rating 32° to 120°F (0° to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, California rate, 3-3-3 temporal, or follow installed panel's NAC. (See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL, ULC, CSFM Model BPSCM provides selection for California rate, in place of temporal. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Description ' Shipping Number Wt. lb (kg) BPS6A 6.5 Amp Booster Power Supply 13(5.9) BPS6AC 6.5 Amp Booster Power Supply (ULC) 13(5.9) BPS6A/230 6.5 Amp Booster Power Supply (220\) 13(5.9) BPS6CAA 6.5 Amp Booster Power Supply with California rate 13(5.9) tBPSJQA 10 Amp Booster Power Supply 13(5.9) BPS1 OAC 10 Amp Booster Power Supply (ULC) 13(5.9) BPS1 OA/230 10 Amp Booster Power Supply (220 13(5.9) BPS1 0CM 10 Amp Booster Power Supply with California rate 13(5.9) Requires installation of sepa- rate battery cabinet. Related Equipment BPS supports batteries greater 12V6A5 7.2 Amp Hour Battery, two required 3.4 (1.6) than 24 Amp hours control applica tions for access 12V10A 10 Amp Hour Battery two required 9.5 (4.3) For earthquake anchorage, 3-TAMP Tamper switch including detailed mounting BC-i EQ Seismic Kit for BC-1. Order BC-1 separately. See note 3. weights and center of gravity BPSEQ Seismic kit for BPS6A or BPS1 0 Booster Power Supplies. See detail, refer to Seismic Applica- note 3 tion Guide 3101676. Approval of panel anchorage to site BC-i Battery Cabinet (up to 2 - 40 Amp Hour Batteries) 58 (26.4) structure may require local BC-2 Battery Cabinet (up to 2 - 17 Amp Hour Batteries) 19(8.6) AHJ, structural or civil engineer i 2Vi 7A 18 Amp Hour Battery, two required (see note 1) 13(5.9) review. 12V24A 24 Amp Hour Battery, two required (see note 1) 20 (9.07) i2V40A 40 Amp Hour Battery, two required (see notes 1, 2) 32 (14.5) 12V50A 50 Amp Hour Battery, two required (see notes 1, 2) 40 (18.14) 1 2V65A 65 Amp Hour Battery, two required (see notes 1, 2) 49 (22.2) Page 4 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 MVVARDS Catadorg, 0- Strobes, Horns, Bells, Chimes FEED 11 ~15 WWZ%Mori,':~ IHFF SAFET' NCHDFNT iANACEMENT çF Field Configurable Ceiling Strobes < > RE,` * @ MEA C ( 7125-1657: 0219 S5389 Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1 971 and ULC-5526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear amber or blue lenses. They are ideal for applications that re- quire differentiation between life safety and mass notification alerts Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - Amber and blue lens models available. See Ordering Information for details. Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULC listed for ceiling or wall use Page 1 of 4 DATA SHEET E85001-0557 Not to be used for installition purposes, Issue 2 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear, amber or blue lenses with optional ALERT markings, they are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red or green lenses. nstal at ion All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/8 (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 6.8' dia. (173 mm) (25 mm) - U.60(15 mm) Light output (effective cd) Percent of UL rating versus angle - Percentage of rated output - 0 Angle - Honzontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output Candela switch (see ordering information). The output / setting is changed by simply opening the device and sliding the switch to the desired setting. The strobe does not have to be removed to change the output setting. / The setting remains visible through a small lnditor window on the front of the device after the cover is closed. WARNING: These deviceswill not operate without electncal power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. 90' EN To listed To next fire alarm j appliance, control panel I end-of-line LiJ LU I or return to control equipment Page 2of4 DATA SHEET E850010557 Not to be used for installation purposes. Issue 2 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value ECS/MNS appliances are selectable by A, B, C, or D designations. Standard output models (mA) High Output models (mA) UL 15 or D 30 or C 75 or B 95 or A 950r ID 115 or C 150 or ;61;,177 or A Rating RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 109 151 281 318 330 392 502 565 16Vfwr 131 194 379 437 432 518 643 693 Standard output models (mA) High output models (mA) Typical 111511 or I'D"30 or CI; 75 or "B" 95 or "A" 95or D 115 arC 150 or B 177 or A Current RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 94 140 273 325 333 392 499 551 20 Vdc 74 108 205 244 259 303 378 429 90 168 194 212 245 306 342 33 Vdc 48 70 124 139 155 180 211 236 16Vter 126 187 368 403 484 570 673 724 20Vfwr 108 156 281 333 380 438 537 604 24Vfwr 97 139 240 270 318 361 434 484 33Vfwr 89 119 197 214 245 269 308 338 Light Output Standard output models High output models Lens Listings Switch Settings (candela) Listings ngs (candela) Switch Settings- ----------------------------------------------- ------------------ --- color Standard Setting Setting Setting Setting color Standard Setting Setting Setting Setting Clear UL 1971 95 cd 75cd 30cd 15 cd Clear UL 1971 177 cd 150 cd 115 cd 95 cd Amber UL 1638 82 cd 65 cd 26 cd 13 cd Amber UL 1638 155 cd 130 cd 100 cd 82 cd Blue UL 1638 40 cd 31 cd 12 cd 6 Cd Blue UL 1638 80 cd 78 cd 59 cd 48 cd Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (Clear). Mounting Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. environment Agency listings! Meets or exceeds year 2004 UL requirements for standards UL1 638 and UL1 971 and Canadian requirements for standards approvals CAN!ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating Clear: UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Amber: CAN!CSA-C22.2 No. 205, CANIULC-S526, UL 1638: selectable 13/26/65/82 cd (GCW*VMA), 82/100/130/155 cd (GCW*VMHA) Blue: CAN!CSA-C22.2 No. 205, CAN/ULC-5526, UL 1638: selectable 6/12/31/40 cd (GCW*VMB), 48/59/78/80 cd (GCW*VMHB) Strobe operating GC-VM series strobes: non-coded, filtered 16-33 Vdc voltage or unfiltered 16-33 Vdc F\NR. Strobe flash rate GC-VM series strobes: one flash per second synchronized with optional G1 M Genesis Signal Master indefinitely within 10 milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Synchronization Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. Synchronization SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Sources BPS6A, BPS10A, APS6A, APS1OA, iO Series, Fireshield Plus 3,5 and 10 zone. Add G1 for G1-CVM &G1-HDVM devices only. ---- Page 3 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2 Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric __________________ candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. LIFE SAFETY & INCIDENT uANAGEMENT Model Housing IMarking I Lens Strobe - 'ship wt. Life safety Appliances (c/vv running man icon screen Drinted on housinal GC-VM White None Clear Selectable 15, 30, 75, or 95 cd 1.8 lb. (0.82 kg.) White "FIRE" GCFR-VM Red "FIRE" GC-VMH White None Selectable high output 95, 115, 150, or 177 cd GCF-VMH White "FIRE" ECS/MNS Appliances (no running man icon on housin& GCWA-VMA White "Alert" Amber Selectable A, B, C, D 1.8 lb. GCWA-VMC Clear GCWN-VMA None ______ Amber GCWN-VMB Blue GCWN-VMC Clear GCWA-VMHA "Alert" Amber (0.82 kg.) Selectable high output A, B, C or D Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMBH Blue GCWN-VMHC Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2017 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2 WA Pon, him S EDWARDS Catoloo Strobes, Horns, Bells, Chimes LiFE SAFETY INCIDENT MANAGEMENT Field Configurable.________One or more patents pending. Ceiling Horn -Strobes .-.. l F I)I ?C 0202 IVIEA CE 7300-1657: Overview Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - idea] for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page lof4 DATA SHEET E850010559 Not to be used for instajlitlon purposes. Issue 1 Application Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 çd. EDWARDS recommends that strobes in sleeping rooms be rated at at least ii 0 Cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Dimensions - (173 mm) J(25Fmm) 0.60(15 mm) Page 2 of 4 Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. G Polarity alarm c FQJ D next oliance, 1-of-line etum to ontrol ipment Note: Strobes must have Continuous voltage. DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 11 Light output - (effective cd) Percent of UL rating versus angle PerCa,1toIULRAUng Current Draw GC-HDVMH High cd Temporal Horn-strobe: High dB Setting GC-HDVM Temporal Horn-strobe: High dB Seng setting UL 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Rating RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 147 190 316 372 341 399 506 570 16Vfwr 189 253 417 451 487 578 670 711 • GC-HDVMH High cd Temporal Horn-strobe: High dB GGaHDVM.Temporal-Horn-strobe: .High dB.Sethng - - Setting Typical l5cd 30rccb 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 24V4c 80 71 108 185 180 212 207 220 217 252 249 304 301 341 338 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 16Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 24Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 33Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 G C-HDVMH High cd Temporal Horn-strobe: Low dB GC-HDVM Temporal Horn-strobe: Low dB Setting Setting Typical 15 cd 30 cd 75 cd 95 cd 65 cd 11.5 cd i50 cd' 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411 24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332 33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232 16Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 20Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 24Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264 33Vfwr 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output UL464 Average Peak High dB Setting Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 85 87.8 95.7 98.7 . Low Setting UL464 Average Peak Temporal Steady Temporal/ Steady Temporal/ Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 80.9 85.9 1 91.8 1 95.1 Notes 1. All values shown are dBA measured at 10 feet (3.01 m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 Specifications '(~_r_=DWARDS Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear) Mounting North-American 4" square box, 2 1/8(54 mm) deep (indoor wall or ceiling applications only). Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-S525 & ULC-5526, year 2004 UL Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies with UL1 480. All horn-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc F\NR (or coded (audible NAC only) when used with optional G1 M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-I-IDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1 M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchronization Sources G1M-RM, SIGA-CC1S, SIGA-MCC1S, BPS6A, BPS10A GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1 M Genesis Signal Master) Temporal audible pattern ½ sec ON, 1/2 see OFF, ½ sec ON, ½ see OFF, ½ see ON, 11/2 sec OFF, then repeat cycle Ordering Information L -F SAFETY & 1 NCiDENr VANAGFMFN Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Catalog Housing Ship Marking Description Wt. lbs Number Color GC-HDVM White None GCEHDVM White 'F " Genesis Ceiling/Wall Horn-Strobe "FIRE IRE" with selectable 15, 30, 75, or 95 cd output 0.82 GCFR-HDVM Red (1.8) GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories G1M-RM Genesis Signal Master— Remote Mount (1-gang) 0.2 (01) 0.5 SIGA-CC1S Intelligent Synchronization Output Module (2-gang) , 0.18 SIGA-MCCIS Intelligent Synchronization Output Module (Plug-in UIO) White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. Page 4of4 DATA SHEET E850010559 Not to be used for install&tion purposes. Issue 1 STATE FIRE MARSHAL LISTING SHEETS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 730O716570229' Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models BPS6A, BTöA, BPS6A/230, BPS10A/230, BPS6CAA, and BPS10CAA remote booster power supplies. *Models APS6A, APS6A/230, APS6CAA, APS10A, and APS1ON230 Auxiliary Power Supply. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 V/240 V, 60 Hz, 50 Hz INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as remote booster power supplies for use with listee's separately listed compatible fire alarm control units to extend the notification appliance circuit. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:229 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. R251-657-25O2:9- Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model Gi M-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 'v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. y:25:.657.:0202. Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models 'EST" G1-HV1S, -HV30, -HV60, -HV-75, G1-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIRF-HOV15, -HOV30, -HOV60, -HOV75, -HOV1I0, GI-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GCHDVMH,tF:Hl, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, GIR-HDV1575, Gi F-HDV1575, and G1 RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33VdcNfwr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, G 1 R-HDV1575, G1F-HDV1575, G1RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, Gi R-HDV1575, Gi F-HDV1575, G1 RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC..HDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division