2675 ROOSEVELT ST; ; FPR2019-0107; Permit
irjillty of PERMIT REPORT Carlsbad Print Date: 12/06/2024 Permit No: FPR2019-0107 Job Address: 2675 ROOSEVELT ST, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel #: 2031013801 Track if: Applied: 05/07/2019 Valuation: $0.00 Lot #: Issued: 11/10/2020 Occupancy Group: Project #: DEV04098 Finaled Close Out: 12/04/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Maldonado, Adalmira Plan Check #: Project Title: BEACHWALK AT ROOSEVELT Description: BEACH WALK AT ROOSEVELT - ALARM MONITORING Applicant: ADVANTAGE SECURITY AND MULTIMEDIA INC MICHAEL CLIFTON 9655 GRANITE RIDGE DR, # STE 200 SAN DIEGO, CA 92123-2676 (858) 586-0335 FEE AMOUNT FIRE Reinspection (per inspection) $193.00 FIRE Reinspection (per inspection) $193.00 FIRE Sprinkler Monitoring $383.00 Total Fees:_- $769.00 Total Payments To Date: $769.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov FPR2019-0107 BEACHWALK AT ROOSEVELT BLDG 1: 2693 ROOSEVELT ST- UNIT 8 2695 ROOSEVELT ST -UNIT 9 BLDG 2: PLAN 2 2675 ROOSEVELT ST - UNIT 1 2677 ROOSEVELT ST - UNIT 2 BLDG 3: PLAN 3 2661 ROOSEVELT ST - UNIT 3 2683 ROOSEVELT ST - UNIT 4 2685 ROOSEVELT ST -UNIT 5 BLDG 4: PLAN 4 2689 ROOSEVELT ST - UNIT 6 2691 ROOSEVELT ST - UNIT 7 2697 ROOSEVELT ST - UNIT 10 2699 ROOSEVELT ST - UNIT 11 BLDG 5: PLAN 3 2701 ROOSE3VELT ST - UNIT 12 2703 ROOSEVELT ST - UNIT 13 2705 ROOSEVELT ST- UNIT 14 BLDG 6: PLAN 2 2709 ROOSEVELT ST - UNIT 15 2711 ROOSEVELT ST - UNIT 16 Contractor's Material and Test Certificate for Aboveground Piping Procedure: Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property Name: Beachwalk © Roosevelt Property Address: 2685, 2687, 2715 Roosevelt St. Carlsbad, CA 92008 Date: 11-24-20 Plans Accepted by Approving Authorities (Names): City Of Carlsbad Fire Department Address: 1635 Faraday Ave., Carlsbad, CA 92008 Installation conforms to accepted plans: II Yes U No Equipment use is approved: Yes U No If no, explain deviations: Instructions Has person in charge of fire equipment been instructed as to Yes 0 No location of control valves and care and maintenance?: If no, explain: Have copies of the following been left on the premises?: System components instructions L1 Yes 0 No Care and maintenance instructions Yes 0 No 3.NFPA25 EYes El No Location of System Supplies Buildings: All buildings supplied by 6" ACP Water City Main on Roosevelt St. by a 4° lateral to riser rooms. Make Model Year of Manufacture Office Size Quantity Temperature Rating TYCO LFII 2017 4.9K 246 165° Sprinklers TYCO LFII 2017 4.9K 88 175° TYCO SAS BBI 2017 4.2K 30 200° TYCO SAS AP 2017 4.2K 1 21 1 200° Pipe and Fittings Type of Pipe: Blazemaster CPVC Type of Fittings: CPVC Alarm Valve Alarm Device Maximum Time to Operate Through Test Connection or Flow Type Make Model Min Sec Indicator Flow Indicator System Sensor 1-Tap Dray Valve Q.O.D. Make Model Serial # Make Model Serial # Dry Pipe Operating Time to Trip Through Test Connection Water Pressure Air Pressure Trip Point Air Press. Time Water Reach Test Outlet \larm Operated Properly? Test Min Sec PSI PSI PSI Min Sec Yes No Without Q.O.D. With Q.O.D. Operation: 0 Pneumatic 0 Electric 0 Hydraulic Piping Supervised? 0 Yes 0 No Detecting Media Supervised? 0 Yes 0 No Deluge and Does valve operate from the manual trip, remote, or both control stations? 0 Yes U No Preaction Valves Is there an accessible facility in each circuit for testing? 0 Yes 0 No If no, explain: Make Model Each Circuit Operate Supv. Loss Alarm? Each Circuit Operate Valve Release? Maximum Time to Operate Release Yes No Yes No Min Sec ___ 0 0 11 11 Pressure Location & Make & Setting Static Pressure Residual Pressure (Flowing) Flow Rate Reducing L Floor Model Left (psi) Outlet (psi) Inlet (psi) I Outlet (psi) Flow (gpm) Valve Test _I Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for 2 hours or 50 psi (3.4 bars) above static pressure in excess of 150 psi (10.2 bars) for 2 hours. Differential dry-pipe valve Test clappers shall be left open during the test to prevent damage. All aboveground leakage shall be stopped. Description Pneumatic: Establish 40 psi (2.7 bars) air pressure and measure drop, which shall not exceed I % psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1 1/2 psi (0.1 bars) in 24 hours. All piping hydrostatically tested at _____psi bars for hrs If no, state reason: Dry piping pneumatically tested U Yes 0 No Equipment operates properly D Yes 0 No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? U Yes 0 No Drain Test Reading of gauge located near water Residual pressure with valve test in I Tests supply test connection: __psi Lbars) connection open wide: __psi (_bars) Underground mains and lead in connections to system risers flushed before connection made to sprinkler piping: Verified by copy of the U-Form No. 85B 0 Yes 0 No Other (explain): Flushed by installer of underground sprinkler piping 0 Yes 0 No If powder-driven fasteners are used in concrete, has representative If no, explain: sample testing been satisfactorily completed? 0 Yes U No Blank Number Used Locations Number Removed Testing Gaskets Welded Piping? D Yes [!J No If yes: Do you certify as the sprinkler contractor that welding procedures comply with the requirements of at least AWS DI0.9, Level AR-3? U Yes U No Welding Do you certify that the welding was performed by welders qualified in compliance with the requirements of at least AWS DI0.9, Level AR-3? 0 Yes LJ No Do you certify that welding was carried out in compliance with a documented quality control procedure to ensure that all discs are retrieved, that openings in piping are smooth, that slao and other welding residue is removed, and that the internal diameters of piping are not penetrated? Yes 0 No Cutouts Do you certify that you have a control feature to ensure that all cutouts (discs) are retrieved? (Discs) I Ill Yes [:]No Hydraulic Nameplate provided? El Yes U No If no, explain: Data Nameplate Date left in service with all control valves open: Remarks Name of Sprinkler Contractor: Test Symons Fire Protection, Inc. Witnessed For Property Owner (signed) TITLE DATE By For Sprinkler Contractor (signed) TITLE DATE Additional Explanation and Notes: Revised: 2013-May-02 Building Inspections Forms and Handouts G:\DSDSystem\HandoutsBuiIding'?Iumbing\ContractorsAboveeroundPiping.docx Page 2 of 2 POTTER PANEL`/ The Symbol of Protection SPRINKLER MONITORING PANEL FPR20I9-0107 2675 ROOSEVELT ST BEACHWALKAT ROOSEVELT - ALARM MONITORING Features: PogramrnabInitiating Device Circuits Class A or Class B Waterfiow Initiating Circuit 2 Wire Smoke Detector Compatibility 1.0 Amp Power Supply 1 Notification Circuit rated at 0.5 Amps Regulated Strobe Synchronization for Potter/AMSECO, Gentex, System DEV04098 2031013801 5/22/2019 FPR20I9-0107 Sensor and Cooper/Wheelock 0.5 Amp Auxiliary Power, Programmable as Constant or Resettable 2 x 16 LCD display with system LEDs for clear system status Keypad for system features P-Link for Remote Annunciator Connections Capacity to charge and house 18AH batteries Onboard Dual Line Digital Alarm Communicator Built-in Ethernet Connection with listed IP Communicator Ability to E-mail system status, reports and system configuration Service Reminder E-mails Electrical Specs AC Mains l.O amp @120 VAC 60Hz Battery (1mA standby) j AiAi Dimensions 18 1/2" H x 14 1/4 W x 4 3/4" D PFC Series 0 go SIGNAUNG c®uS LISTED 9 S735 7 165-0328:0204 General Description The PFC-6006 is a listed small conventional fire system ideally suited to monitor a small fire system such as a fire sprinkler system. The first input is selectable as a Class A or Class B water flow input and the other five zones are selectable from a menu of options including two-wire smoke detection. The panel has a 1.0 amp power supply that powers the panel, charges the batteries and supplies 0.5 amps to a notification appliance circuit and 0.5 amps of auxiliary power. The auxiliary power is programmable as constant or resettable. The control panel is in a metal cabinet with a key lock and lexan window for viewing the system status. The printed circuit assembly is mounted for quick removal and installation to allow the cabinet to be installed with minimal effort. The cabinet houses up to two 12VDC, 18 AH batteries. The display is a thirty-two (32) character LCD with system status LEDs. The system status is clearly displayed and the panel includes a history buffer for past events. The key pad allows navigation into the system menu, limited programming and system control. The condition and events on the panel are clearly displayed to allow the user and installer to determine the system status. The panel has adual telephone line digital alarm communicator transmitter (DACT) built on-board. One or both telephone lines may be enabled to allow communication to a remote monitoring station. In addition, an updated panel configuration may be sent to the panel through the telephone lines. The panel has line in and line out to allow the panel to be installed ahead of other telephone equipment on the premises. The panel will support upto four (4) of the RA-6075 remote annunciators on the P-Link bus. These annunciators include a metal enclosure with a key lock and provide full functionality of the system. The panel is pre-programmed from the factory for monitoring a typical wet or dry fire sprinkler system. The programming maybe changed using the Potter Fire Panel Programmer(available free from www.pottersignal. corn) and a standard Ethernet cable. The default program is as follows: Input 1 - Waterfiow Input 2 - Smoke Detection (two-wire) Input 3 - Manual Pull Station Input 4 - Non-Latching Supervisory Input 5 - Valve Tamper Input 6 - Valve Tamper Potter Electric Signal Co., LLC • St. Louis, MO • CustService: 866-240-1870 Tech Support: 866-956-1211 Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT #883 003 8 - REV A PAGE 1 OF 2 06113 PFC-6006 Sprinkler Monitoring Panel ALARM SIGNAL ACTIVATION PRESS LEFT & RIGHT ARROW KEYS AT SAME I1METOTRIG(SER ALARM SIGNAL ACTIVATION, A CAU11ON ONLY DETECTORS THAT ARE SHOWN IN THE COMPA11BILITY LIST ARETO BE USED. (iNVENTIONALRE PANEL!FI (DPOTTER FFC-6OQ The Symbol of Protection SPRINKLER MONITORING PANEL General Description (Cont.) In the standard program, Input I is defaulted as a Water flow zone. Input 1 is the only Class A/Class B zone. The panel will automati- cally determine Class A or B based on wiring and the presence of the end of line resistor. All of the inputs may be programmed for General Alarm, Waterfiow, Two-Wire Smoke Detector, Heat Detector, Manual Pull Station, Non-latching Supervisory, Latching Supervisory, or Valve Tamper. The NAC is listed for strobe synchronization and the panel is listed with Potter/AMSECO, Gentex, System Sensor, and Cooper Wheelock signals. Please refer to the Potter Notification Compatibility Docu- ment for the maximum number of strobe devices that may be con- nected. The maximum output is 0.5 amps. The Ethernet connection may be connected to a building network with Internet to provide e-mail notifications of system status, reports, or system configuration. In addition, the Ethernet connection is listed for IP reporting to a monitoring station. CAUTION: De-Energize Unit Prior to Servicing 1 PO-ff FR Connect to separate WHITE 12OVAC6OHz BLACK The Symbol of Proteciiyn unswitched AC circuit Use 14 AWG or heavier gauge wire with 600V insulation WARNING: RADIO FREQUENCY FROM TRANSMI1NG DEVICES MAY IMPAIR INTENDED MSE OPERATION OF THE CONTROL UNIT. MAINTAIN A MINIMUM OF 30 CM BETWEEN TRANSMITUNG DEVICES AND CONTROL UNIT. AVERTISSEMENT: LES RADIOFREQUENCES EMISES PAR LES DISPOS[I1FS DIE TRANSMISSION PEUVENT NUIRE AU FONCTIONNEMENT PREVU DU POSTE DE CONTROLE. MAINTENIR UNE DISTANCE D'AU MOINS 30 CM ENTRE LES DIsPOSmFS DE TRANSMISSION El LE POSTE DE CONTROLE. Primary AC 120VAC. 80H4 .75 AMP Min Low AC Detect 98VAC Battery Chargog 27.3VDC@,5A FUSE Low Battery Detect @20.4vDC All Circuit Impedance Value, Short CIrcuit: 0 Ohms SEMNS O pen Circoit>10K Earth Fault loony terminal: 0 Ohms c.J[)us Main Fuse Specificotion USIBIl 1.6A.250VAC FIRE ALARM Batt. Fuse Specihcotlon EQS PAlEsT 2.5A-250VAC 3JS simeoLsysTEw CONTROL 01ST F.C.C. This des,cn has been senSed to —ply with FCC Rules Past 15, Class A Operation is subject to the foBowing conditions: ThIs device may net cause radio interference. This device must accept any interference received including any that may cause undesired operation. Acknowledgements Genter, Cooper Wheelock and System Sensor • synchronization protocols used with permission. Cooper Wlreelouk Patent Nos. 5.400,009. Potter Electric Signal Company LLC PFC-6006 US: POTALOt BSMP Complies with 47 CFR Part 68. Mad. in USA. See board lot Senal 0. P/N 5406280 (10/31/2)12) cp080000 ORLORM OEORTHFOJJIJ 0 &PtR080ttf O80EOcE0 0 r,nOuuoc 0EJ 0 MEK] M1 ED LAMP TEST: PRESS FErdLERt, 151, PASSWORD, 63. PRESSTHE IESCI KEY WHEN DONE. FE EO.L, E.O.L. kilL E.O.L HilL E.UL Programming 6 Conventional Inputs, fully programmable Connection & support 2-wire smoke detector Requirements System must be fully tested after installation. Intended for indoor use in dry locations only. Bette Separation of power limited wiring from non-power limited wiring must beat least 1/4. Install In accordance wirh Installation manual Part Number 5403559. and Operating instructions - Part 85406282 See Smoke Detector Compatibility irlentifer'A NFPA Commercial Protected Premises Control Unit for UL Installation,: 13, 75, and NFPA 72. Alarm activation requiring activation of two or more automatic detection devices shall not utilIze any time delay. Setvice Use for UL Installations: - Local - Remote Station - Proprietary Central Station Battery contrectlno lnorvpower limited). SERVICE USE P341) COMMERCIAL PROTECTED PREMISES UNIT FOR ULC INSTALLATIONS: Use two 12) t2V batteries connected in series. WIRING METHODS SHALL BE IN ACCORDANCE WITH CSA C22.1, SAFETY STANDAHO FOR ELECTRICAL INSTALLATIONS, CANADIAN ELECTRICAL CODE, PART I, SECTIONS 32. LOCAL SERVICE TYPES (N ON-CODED): A, M, 55, WE. Potter Electric Signal Co., LLC St. Louis, M0 CustService: 866-240-1870 • Tech Support: 866-956-1211 Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MKT #8830038- REVA PAGE 2 0F2 06/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17'T65-0328 0204) Page 1 of 1 CATEGORY: 7165FIREALARMCONTROLUNIT (COMMERCIAL) - 1 LISTEE: (iqtter Electric -Sign c'1609 Park 370 Place, Hazelwood, 63042 United States Contact Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: ------ 0odelPFC-6006 fire alarm control paneL Automatic, Manua waterfiow and spr:nklerj supervisory type device and local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. RATING: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 07-25-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (Listing Expires 30, 20i Authonzed By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER CPHOTOELECTR The Symbol of Protection MOKEDETECTOR UL, ULC, and CSFM Listed, FM Approved Light Source: (}aAlAs infrared Emitting Diode Rated Voltage: 17.7 - 33.0 VDC Working Voltage: 15.0-33.0 VDC Maximum Voltage: 42 VDC 24 VD Surge Current: 160 IiA Max. at 24 VDC m Current: 150 mA Max. at 24 VDCJ Ambient Temperature: 32°F to 120°F (0°C to 49°C) Sensitivity Test Feature: Automatic Sensitivity window verification test. Mounting: Refer to Potter SB Series Smoke Detector Base series, bulletin no. 8840008. Stock number: 1430011 Standard Features Low profile, 1.8" high (with base) 2 or 4 wire base compatibility, relay bases available Highly stable operation, RFlFransient protection Low standby current, 45 IiA at 24 VDC Two built-in power/sensitivity supervision/alarm LED's Non-directional smoke chamber Vandal resistant security locking feature Built-in magnetic go/no go detector test feature Removable smoke labyrinth for cleaning or replacement Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 7. Inspection, Testing and Maintenance. Compatible with IS-24 ionization detectors Backwards compatible with Potter PS and IS detectors. Compatible with Potter releasing controls Operation The PS-24 photoelectric smoke detector utilizes two bi-colored LED's for indication of status. In a normal standby condition the LED's flash green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sensitivity window the LED's will flash red every 3 seconds. When the detector senses smoke and goes into alarm the status LED's will latch on red. The detector utilizes an infrared LED light source and silicon photo diode receiving element in the smoke chamber. In a normal standby condition, the receiving element receives no lightfromthe pulsingLED light source. In the event of afire, smoke enters the detector smoke chamber and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Signals are processed and compared to a reference level, and when two consecutive signals exceeding the reference level are received within a specified period of time, the time delay circuit triggers the SCR switch to activate the alarm signal. The status LED's light continuously during the alarm period. Application The PS-24 can be used in all areas where Photoelectric Smoke Detectors are required. The wide range smoke chamber makes thePS-24 well suited for fires ranging from smoldering to flaming fires. SB Series Style basesmay be usedwiththe PS-24. Current interchangeable/ compatible devices are the IS-24 ionization detector. Potter Electric Signal Co., LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support: 866-956-1211 • Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MKT. 98840007 - REV G PAGE 1 OF 2 8104 (E)POTTER PHOTOELECTRIC The Symbol of Protection SMOKE DETECTOR Engineering Specifications The contractor shall furnish and install where indicated on the plans, Potter Model PS-24 photoelectric smoke detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire alarm panel. The base shall permit direct interchange with Potter, PS-24H, combination photoelectric/heat detector and IS-24 ionization type smoke detector. The base shall be appropriate twist-lock base SB Series. In the event of partial or complete retrofit, the PS-24 may be used in conjunction with, or as a replacement for, Potter detectors (PS-24, PS-24H and the IS-24) the SB base applications. The smoke detector shall have two flashing status LED's for visual supervision. When the detector is in standby condition the LED's will flashgreen. When the detector is outside the UIL listed sensitivity window the LED's will flash red. When the detector is actuated, the flashing LED's will latch on red. The detector may be reset by actuating the control panel reset switch. The sensitivity ofthe detector shall be capable of being measured. It shall be possible to perform a functional test of the detector without the need of generating smoke. The sensitivity of the detector shall be monitored automatically and continuously to verify that it is operating within the listed sensitivity range. To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Specifications subject to change without notice. PS-24 Sensitivity Test Feature The PS-24 Photoelectric Smoke Detector has a built-in automatic sensitivity test feature. In normal condition, both LED's flash green. When the sensitivity drifts outside of its sensitivity limits, both LED's flash red. In the alarm state both LED's are red continuously. When the sensitivity drifts outside of its sensitivity limits and both LED's flash red, the device needs to be cleaned or returned to the factory for cleaning. PRINTED IN USA MKT. 118840007- REV G PAGE 2 OF 2 8/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 72:032891 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: [Pt Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Models BPS-2, PS-24H anPS-24 photoelectric type smoke detectors. Unit with sufftx " m (ptoysasuppiernental heat sensor. Refer to listee's data sheetfor additional detailed product description and operational considerations. - RATING: 12 VDC and 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units when used in conjunction with listee's listed bases (CSFM Listing No. 7300-0328:153). Models with supplemental heat sensor are not approved for use in lieu of the required heat detectors. XLF: 7272-0410:0107 9-11-2001 To This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Vi • operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 stingExpire [June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Universal full event sole path cellular & dual path cellular &Ior IP commercial fire alarm reporting from any panel brand, virtually anywhere For use as primary or backup communications on all 12V-24V control panels and FACPs that communicate using Contact ID and 4/2 (such as on legacy panels) Reports to any Central Station nationwide, via dial up or IP Communicate critical life and safety alarm reports on cyber-protected multibillion-dollar cellular nationwide reliable networks, Verizon Network Certified or AT&T, for maximum security & liability protection Easy, flexible installation, activation & online account management Cost-saving models and plans for any code requirement. Substantial savings over monthly dedicated landline charges. And, $100 saving incentive for system upgrades from old radios (all makes) and old POTs landlines, as well as new installations StarLink Fire Commercial Fire Alarm Communicators. COMM ERCIALFIRE CELLULAR &lP Sole & Dual PathCel-lular &tor IP UL and NFPA 72 Fire Code-Compliant, the StarLink Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. With broadest coverage footprint available in Verizon Network Certified1M CDMA or GSM 314G models on the AT&T network, as well as mercantile models, all provide the most economical solution and for easy, versatile installation. Safeguard Accounts & Reliability. For applications currently relying upon quickly-disappearing traditional phone lines, StarLink wireless communicators can be used for primary or backup communications, and will not only safeguard the fire alarm reporting transmissions for the future, but provide the end-user monthly savings for each costly FACP-dedicated landline they replace. And, for upgrading older wireless fire alarm communicators on 2G and other phased-out cellular networks, all StarLink Fire radios, offer a $100 tradeup incentive to help defray the cost of the hardware replacement to the advanced state-of-the-art StarLink model of choice. Flexible Performance & Reporting Options. StarLink Fire provides full data reporting, in sole and dual path, as a primary or backup, to any central station of your choice, without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes and requirements, with supervisory check-ins from 200 seconds, to 5-minutes, to an hour. The units are very easily activated, plans and options are selected, and 24/7 account management is provided all through www.napcocomnet.com. And, StarLink Fire Communicators are easily connected to any panel or Fire Alarm Control Panel (FACP) standardly operating between 12V and 24V. Flexible in any application, StarLink Fire also comes in standard, or Mercantile Models in metal housings, with code-compliant supervision, with or without using conduit; and choice of power options, powered by the panel or using its own 120V Power Supply. - - .-. 4 ; _J 1 - -- Code-compliant standard or mercantile metal models (right and left respectively) Napco StarLink Universal Fire Alarm Communicators verqg, NETWORK CERTIFIED mo NFPA Sole Path Cellular and Dual Path Cellular &/or IP Models Choice of plans (varies by model) - check-ins from 200 seconds, to 5-minutes to 1 hour, Verizon or AT&T Patented Signal BoostTm signal amplification circuit and high-gain performance antenna for longer range and reliability nationwide Money-saving Tradeup incentive credit Bonus: Full High-Speed Napco Panel remote uploading! downloading COMPLIANCES. NFPA72 Editions: 2016,2013,2010,20071- UL 864, 9th Ed., UL1 610, UL985, UL1 023, NYCFD; CSFM NAPCD (IIEDAL 7 \ StarLink Fire Specifications STANDARD MODELS: Durable ABS plastic housing includes three keyhole slots for mounting (for commercial application, aligns with triple gang boxes.) Dimensions: 5-3/8"x 7-7/8' 1-7/8" (HxWxD) Weight: 13.5 oz 3 LED Indicators - Green, Signal Strength; Amber- Busy! Activation; Red-Trouble Patented Signal Boost signal amplification circuit and high- gain performance antenna Operating Environment: 0 to 49° C (32-1200F), up to 93% humidity (non-condensing) 12V - 24V Universal FACP Support, auto-current sensing. Support all brands communicating in Contact ID and 4/2 Powered by Panel, Low current draw, 71 mA standby, 200mA transmit MERCANTILE MODELS (similar to above, with): Locking Metal Enclosure with Hinged door & 2 key-slots for wall mounting (LED indicators, inside). Dimensions: 9-5/8"x 11-3/4" x 3-3/8"D (Hx'fD) Weight: 8 lbs (max., power supply models) Electrical Ratings for 120VAC, 60Hz For Models with Power Supply: Input Voltage: 120VAC Nominal Input Current: 400mA maximum Maximum Charging Current: 200mA Electrical Ratings for +12V For Models without Power Supply: Input Voltage: 11-15VDC (power-limited output from listed control panel) Input Current: 71 mA with peak RF transmission current of 200mA. Electrical Ratings for the IN 1 Burg/Fire Input: Input Voltage: 9-15VDC Maximum Input Current: Up to 2mA from FACP NAC circuit Electrical Ratings for IN 2 and IN 3: Maximum Loop Voltage: 15VDC Maximum Loop Current: 1.2mA Electrical Ratings for 3 PGM Outputs: Open Collector Outputs: Maximum voltage 3V when active; iSV maximum when not active Maximum PGM Sink Current: 50mA mount. Operating Environment 0 to 49°C (32-1200F), up to 93% humidity (non-condensing) 12V - 24V Universal FACP Support, auto-current sensing. Support all brands communicating in Contact ID and 4/2. Ordering Information COMMERCIAL FIRE SOLE PATH CELLULAR & DUAL PATH CELLULAR &IOR IP ("1" MODELS):* SLE-CDMA-FIRE Standard ABS (Red) Fire Sole Path Alarm Communicator, Cellular CDMA, Verizon-Network Certified SLE-CDMAI-FIRE as above, Dual Path Alarm Communicator, Cellular &/or IP (primary or backup, selectable) SLECDMA-CFB-PS Commercial Fire Mercantile model in red metal housing, CDMA, Verizon-Network Certified. Direct 1 2OVAC Powered (w/ provisions for backup battery/charger). Or, Optional TRF1 2 plug-in transformer may be used, where codes permit SLECDMA-CFB Commercial Fire Mercantile model in red metal housing on CDMA, Verizon-Network Certified Powered directly from control panel Note: Substitute prefix "SLE3/4G-" on any models above for AT&T 3/4G Network ACCESSORIES: SLE-DLEXT Optional, as above, for downloading, extends distance to Napco panel up to 100' TRF1 2 Optional Plug in AC Transformer, 16.5V / 20VA (use is subject to local code compliance) SLE-DLCBL Optional High-Speed Napco Panel Up/download cable Also Available: StarLink Intrusion Radios in standard and mercantile versions SLE-GSM-3/4G Standard Burglary Radio (Black), GSM 3/4G on AT&T Network powered by panel. SLE-CDMA as above, but CDMA communications, Verizon-Network Certified. SLECDMA-CB Commercial Burglary COMA Radio, Verizon Certified, in white metal housing. Powered directly from control panel. SLE3/4G-CB as above, but GSM 314G on AT&T Network. SLE3/4G-CB-TF Commercial Burglary COMA, Verizon Certified in white metal housing with power supply - - -• - powered by plug-in 16.5V I 20VA transformer & provision for battery. venzp StarLink Fire.NETWORK CERTIFIED COMMERCIAL FIRE CELLULAR & IP 333 Bayview Ave., Amityville, NY 11701 USA 1-800-645-9445 Fax: 1-631-789-9292 www.napcosecurity.com [] NFPA1 COMPLIANCES: NFPA72 Editions: 2016,2013,2010,2007; UL864, 9th Ed., UL161O, UL985, UL1023; NYCFD; CSFM *StaJnk Fire are also rated to support Intrusion/Burglary alarm reports where applicable. StarLink' and Signal Boost are trademarks of NAPCO. Pats. Pending. Specifications subject to change. IBNAPCO, NAPCO SecurityTechnologies Inc. (N/.SoAQ:NSSc) A676E 2017.1 * Verizon and Verizon Network Certified, UL, AT&T and other trademarks, are trademarks of their respective companies, and are unaffiliated with NAPCO. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7360-6992:0144 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Napco333 BayviewAvene, Amityville, NY 11701 Contact David Wagner (631) 842-9400 Fax (631) 842-2726 Email: dwagnernapcosecurity.com DESIGN: Models SLE3I4G-CB, SLE3/4G-CB-TF, SLE3/4G-CFB, SLE3/4G-CFB-PS, SLE-CDMA, (Si:abMA:FiR SLE-GSM-3/4G, SLE-GSM-FIRE, SLECDMA-CB, SLECDMA-CB-TF, SLECDMA-CFB, SLECDMA-CFB-PS, *SLELTEVFIRE *SLE..LTEV8D *SLELTEV *SLELTEVCFB..PS *SLELTEVC B-TF, *SLE..LTEVCFB and *SLELTEVCB Communicators. Models SLECDMAI-CFB-PS, SLE3/4Gl-CFB-PS, SLECDMAI-CB-TF, SLE3/4G1-CB-TF, SLECDMAI-CFB, SLE3/4Gl-CFB, SLECDMAI-CB, SLE3/4Gl-CB, SLE-GSMI-3/4G, SLE-CDMAI, SLE-GSMI-FIRE and SLE-CDMAI-FIRE Dual Path Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 Vac - SLE3/4G-CB, SLE3/4Gl-CB-TF, SLE3/4G-CFB-PS, SLE3/4Gl-CFB-PS, SLECDMA-CFB-PS, SLECDMAI-CFB-PS, SLECDMA-CB-TF, SLECDMAI-CB-TF, *SLE.LTEVCFBPS *SLELTEVCB.TF 10-15 Vdc- SLECDMAI-CB, SLE3/4Gl-CB, SLE-GSMI-3/4G, SLE-CDMAI, *SLELTEV *SLELTEV8D *SLE..LTEV.CB 10-25 Vdc- SLECDMAI-CFB, SLE3/4Gl-CFB, SLE-GSMl-FIRE, SLE-CDMAI-FIRE, *SLELTEVFIRE *SLELTEVCFB 11-15 Vdc- SLE3/4G-CB, SLE-CDMA, SLE-GSM-3/4G, SLECDMA-CB 11-25 Vdc - SLE3/4G-CFB, SLECDMA-CFB, SLE-CDMA-FIRE, SLE-GSM-FIRE INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev 07-06-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (Listing Expires' June 30, Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division