HomeMy WebLinkAbout7720 RANCHO SANTA FE RD; ; FA150035; Permit12/6/24,10:51 AM FA150035 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA150035 7720 RANCHO Job Address: Status: ISSUED SANTA FE RD Permit Type: FALARM Applied 6/10/2015 Parcel No: 2230602800 Approved: 6/12/2015 Lot #: U Reference No.: Issued: 6/12/2015 PC #: Inspector: Project Title: HP INVESTORS INSTALL A NEW FIRE SPRINKLER! ELEVATOR RECALL SYSTEM PER PLANS. INCLUDE DETECTORS AT THE FACU, ELEV. MACH. ROOM, AND EACH ELEVATOR LANDING. INCLUE RELASY FOR PRIMARY AND SECONDARY RECALL AND FIRE HAT ACTIVATION. -CONNECT AND MONITOR ALL FIRE SPRINKLER DEVICES. -THIS DEDICATED FUNCTION FIRE ALARM CONTROL UNIT WILL REPORT TO A CENTRAL STATION. NOTE: THE COMMUNICAITON METHOD FOR THIS SYTEM IS S AGSM UNIVERSAL WIRELESS ALARM COMMUNICATOR. THE COMMUNICATOR SHALL BE INSTALLED PER THE REQUIREMENTS OF NFPA72, 2013 SECTION 26.6.3.1. -THE DOCUMENTS FOR THIS PROJECT WILL BE STORED IN A CABINET NEXT TO THE FACU. Applicant: BAY ALARM COMPANY 4883 RONSON CT SUTE C SAN DIEGO, CA 92111 714-719-9334 Owner: SANTA FE LA COSTA L LC 9404 GENESEE AVE #330 LA JOLLA CA about:blank 1/2 12/6/24,10:51 AM FA150035 Permit Data Fees ($) Add'l Fees ($) Total ($) Balance ($) 289 0 289 0 about:blank 2/2 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 PROTECTED PREMISE HP Investors 7720 Rancho Santa Fe Rd. Carlsbad, CA 92009 MONITORING COMPANY Bay Alarm Company 60 Berry Drive Pacheco, CA 94553 800-470-1000 California Alarm Operating License Number: ACO28 HI. EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 92111 1(800)470-1000 Contractor License # 880138 I.SJ: •1 11 IPGSM-4G Single or Dual Path Commercial Fire Communicator General The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel (FACP) that has a built-in dialer. This single or dual path com- municator connects directly to the primary and secondary communication ports of a fire panels Digital Alarm Communi- cator Transmitter (DACT). It offers three selectable reporting paths which include: Cellular only, IP only, or IP primary/cellu- lar backup. All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station. The state of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-1 and 800 PLUS services, providing true redundancy and multipath message delivery. Alternative communication methods are critical in the market- place due to VoIP (Voice over IP), migration from POTS (Plain Old Telephone Service) and growth of digital radio networks. The IPGSM-46's single path communications solution allows one technology to be used (Either IP or cellular) to provide the appropriate connectivity to a central station. For added reliabil- ity, our exclusive dual path solution allows both technologies (IP and cellular) to be used together for maximum survivability or for local jurisdiction requirements that specify a dual tech- nology system. The IPGSM-4G is designed to operate over the most common cellular networks including 2G,3G and 4G. Its multi-GSM plat- form technology automatically chooses the best available cel- lular signal in the area based on signal strength and seamlessly self-adjusts to maintain critical life safety communi- cation. In addition, it connects to any type of customer pro- vided Ethernet 10/100 base network connection (LAN or WAN), DSL model or cable modem. Our selectable reporting path feature allows the radio to be configured for a single or dual path solution as well as the appropriate supervision inter- vals based on NFPA 72 requirements. (See diagram below for selectable paths and supervision timing intervals.) Selectable Path Description Supervision Times 2010 GSM Single Path (cellular only) 5 minutes 2010 IP Single Path (IP only) 5 minutes 2010 IP & GSM Dual Path (IP and cellular) 24 hours 2013 GSM Single Path (cellular only) 1 hour 2013 IP Single Path (IP only) 1 hour 2013 IP & GSM Dual Path (IP and cellular) 6 hours Features Saves the cost of two dedicated phone lines. Single or dual path communications. (Can communicate to central station using cellular technology, Internet or both. Requires no change to the existing Fire Alarm Control Panel configuration. (Connects directly to the primary and secondary telephone ports of a DACT.) Multi-GSM platform compatibility for 2G, 3G and 4G net- works. Operates over the following communication protocols: HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) GPRS (2G). Selectable reporting paths and supervision intervals to meet NFPA 72, chapter 26 requirements. (Compliant with NFPA 722010 and 2013 supervision requirements.) Works over any type of customer provided Ethernet 10/100 based network connection (LAN or WAN), DSL modem or cable modem. Data transmits over standard contact-ID protocol but is secured with the industry's advanced encryption standard (AES 256 bit). Supports both dynamic (DHCP) or Public and Private Static IP addressing. Built-In Power Supply module: On board charging circuit design accommodates back-up battery. Includes primary power and battery supervision. Diagnostic LEDs: Signal strength and status indicators. Reliable connection: IP and GSM connection tested every day. QOS: Quality of Service diagnostics via AlarmNet conveys vital communicator information including when message was received, signal strength, and message path used. 7720P Hand-held programmer for easy setup. Operation When an event occurs, the Fire Alarm Control Panel goes off hook to dial the central station. The IPGSM-4G Dialer Capture Module detects the off-hook condition and provides the fire panel with a dial tone. When the fire panel detects the dial tone, it begins dialing the central station. After the dialing is completed, the Dialer Capture Module returns a handshake to the fire panel. The fire panel then sends the contact ID reports to the Dialer Capture Module, which in turn sends a kiss-off after the report is successfully received from the fire panel. The Dialer Capture Module sends the contact ID reports to the IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- tions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent on configuration). Easy to Program The IPGSM-4G communicator can be pie-programmed using the 7720P programmer to enter all central-station information. This is saved to the IPGSM-4G communicator panel memory. When the IPGSM-4G communicator is installed at the site and connected to the Internet/Intranet, it registers itself with the AlarmNet receiver. For most installations, the only required parameters are: Primary City ID (two digits) obtained from your monitoring station. Primary Central Station ID (two digits) obtained from your monitoring station. Primary Subscriber ID (four digits) obtained from your mon- itoring station. Communication Modules MAC ID, and MAC CRC number located on outside of box, and inside of the module. All of these parameters are assigned by the monitoring station. NOTE: Some assembly is required. See Installation and Setup Guide #800-12454 for full details. Fire Communicator Capability The IPGSM-4G is compatible with fire panels that use the Contact ID communications format as described in the SIA DC-05 standard. AlarmNet Honeywell's AlarmNet has been the nationwide leader in alarm communications technology since 1986. A reliable alter- native for the transmission of alarm signals, our radio network provides extensive coverage in the United States and Canada. AlarmNet Network Control center processes signals from pow- erful servers in multiple locations equipped with 24/7 infra- structure support. The AlarmNet network consist of redundant hardware servers, hot back-up databases and generators with battery back-up at all locations to ensure continuity of service. Signals from Alarm-Net are transmitted to the central station's receivers using multiple communications paths consisting of the Internet, radio network or toll-free POTS service. Installation Requirements UL COMPLIANCE To meet UL864/NFPA, ensure the following: IPGSM-4G must be installed in accordance with NFPA (National Fire Protection Association) standards 70 and 72. IPGSM-4G must be mounted in the same room and within 20 feet of the fire panel. IPGSM-4G, and all equipment used for the IP connection (such as the router, hub, modem, etc.) shall be listed, must be powered from an un-switched branch circuit, and be pro- vided with appropriate standby power. IPGSM-4G must use the 7AH battery (not supplied) to pro- vide 24-hour backup capability. Electrical Specifications Transformer: - Primary 120VAC, 60Hz, 0.5A. - Secondary: 18VDC, 50VA. Battery: - One 12 V 7.0 AH lead-acid battery (not supplied). - Battery charging current: 1 Amp maximum. - Battery discharge curent: Standby 230mA, Active 950mA. Cabinet Specifications Dimensions: 14.875° H x 12.75° W x 3.0° D (37.8 cm H x 32.4 cm W x 7.6 cm D). Color: Red. Shipping Specifications Weight: 5.3 lbs. (6.94 kg). Dimensions: 15.625° H x 13.79° W x 9.25° D (39.7 cm H x 34.9 cm W x 23.9 cm D) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (non condensing at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Product Line Information IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- cator Panel. Includes red cabinet with Ademco key and lock, wall outlet box, Dialer Capture Module, IGSM Communications Module, antenna & mounting adapter, PowerBoostl power supply, LED display board, transformer, manual, & required screws, cables, etc. Antenna Kits GSM-ANT3DB25KT: 25 ft. antenna kit. Includes GSM-ANT3DB, WA7626-CA adapter cable, and a 25' RF cable. GSM-ANT3DB50KT: 50 ft. antenna kit. Includes GSM-ANT3DB, WA7626-CA adapter cable, and a 50' RF cable. Antenna External Hardware GSM-ANT3DB: 3db gain external/remote antenna. WA7626-CA: SNA to N Adapter. 7626-50HC: 50 ft. antenna cable, low loss. 7626-25HC: 25 ft. antenna cable, low loss. NOTE: The GSM-ANT3DB and the WA 7626-CA are both required for installing an external antenna along with the necessary cable needed (7626-50HC: 50 ft. or 7626-25HC: 25 ft.) Other Accessories 7720P: IPGSM-43 hand held programmer. HPTCOVER: Plug in transformer box for IPGSM communicator. BAT-1270: Battery 12 Volts, 7 AH, sealed. Agency Listings and Approvals The listings and approvals below apply to the basic IPGSM-4G communicator panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S789. CSFM: 7300-1645:0199. FDNY: COA #6150. Page 2 of 3— DH-60769:B • 3/25/13 www.Iioneywell.com This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. 02014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I, Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpp_techserv@honeywelI.com www.honeywellpower.com DH-60769:B April 2014 0 Made in the U.S.A. Iso 9001 ® U.S. Registered Trademark ________________ © 2014 Honeywell International Inc. Page 3 of 3 OIALITY SYSTEMS Features Multiple configurations for installations: - Single- and dual-circuit models - Fixed temp and combination fixed- temp/rate-of-rise 135°F 01194°F ratings. Plain housing for residential installations (Model 5601 P) Easy-to-use terminal screws A broad range of back box mounting options: - Single gang - 3.5" and 4 Octagonal - 4" square with square to round plaster ring Reversible mounting bracket Agency Listings ®4jMEA , LISTED 02101 APPROVED 3016008 approved 99-03-0 7270-1209.227 Multiple configu ratio ms. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit rodels are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate,c,rrise (ROR) activation. The ROR element of the fixed/ROR models is -storable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mcnts to single-gang and octagonal back boxes. And these models. accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature modes are identified FX, while combination fixed/rate-of-rise units ars marked FX/ROR. The 5600 series also provides a post-activatic-i indicator in the form of a collector. When the detector is activated. :he collector drops from the unit, making it easy to identify the unit ' alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series modl number _________.listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall berated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (83°C) per minute.The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Maximum Installation Temperature 5601 F, 5603, 5621, and 5623: 100°F (38°C) 5602,5604,5622, and 5624:150'F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 457 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602,5604,5622, and 5624:194F (90°C) Weight 6 oz. (l7ograms) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601 P, 5602,5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box -- 4-inch square back box with a square to round plaster ring Operating Voltage! Contact Ratings 6-125VAC / 3A 6-28VDC/1A 125VDC/0.3A 250VDC/0.1A Input Terminals 14-22 AWG 5601P 5602,S622 Orderina Information 5603, 5623 5604, 5624 5621 5601 P Single None 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet >< 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) STEM 5°ENZS'OR 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2 . Fax: 630-377-6495 02 M systen, Sensor. Product specificationssubject to odiangewithout notice, Visit systernsensorcorn for fth, data sheet , - CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . . OF THE STATE FIRE MARSHAL I -OFFICE • FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. 7300-1645:0199 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 I Email: issa.khouryawadHoneywell.com DESIGN: Models iPGSM-COM, iPGSM-DP, and iPGSM-4G Internet and Digital Cellular Fire Communicators. Units are suitable for residential and commercial applications. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a control unit accessory for use with *separately listed compatible commercial and residential fire alarm control units. Refer to listee's installation Instruction Manual for details. I NOTE: Burglary and other non-fire functions were not examined. iPGSM-COM, iPGSM-DP formerly listed in 7300-1645:0183. I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I _____ LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 11 LISTING No. 7270-1653:0167 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.Iinhart@systemsensor.com DESIGN: Models 5601 5601 P, 5602, 5621, and 5622 combination fixed-temperature and rate-of-rise type and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models 5601, 5601P, 5603, 5621, & 5623 have a fixed temperature of 135°F. Models 5602, 5604, 5622, & 5624 have a fixed temperature of 194°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details and UL directory for dimensions. NOTE: Formerly 7270-1209:227 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 8205 Ronson Rd. Ste F San Diego, CA 92111 (800)470-1000 Contractor License # 880138 PROTECTED PREMISE HP Investors 7720 Rancho Santa Fe Rd. Carlsbad, CA 92009 MONITORING COMPANY Bay Alarm Company 60 Berry Drive Pacheco, CA 94553 800-470-1000 California Alarm Operating License Number: ACO28 III. EQUIPMENT SUPPLIER & INSTALLER 4883 Ronson Court, Suite C San Diego, CA 92111 1(800)470-1000 Contractor License # 880138 DF-52416:D • A3-20 MS-5UD(E)/MS-1 OUD(E) Series Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel FIreLlTeALarrns by. Honeywell Control/Communicators I The MS-51JID-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-i OUD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 10UD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterilow devices, tamper switches, and other normally-open contact devices. Refer to the Fire•Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series Internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-I0UD-7E offers the same fea- tures as the MS-5UD-3 and MS-10UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see DF-60440. Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). Style B (Class B) IDC (Initiating Device Circuit) - MS-5UD-3 - five lDCs. - MS-10UD-7 - ten lDCs. Style Y (Class B) NAC (Notification Appliance Circuit) - spe- cial application power - MS-5UD-3 - four NACs. - MS-1 OUD-7 - four NACs. Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). - Temporal or Steady Signal. - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and lDCs (2 required for MS-10UD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A © 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-1 OUD-7. Optional Dress Panel DP-51050 Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. - Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. DF-52416:D.07/26/2010—Page 1 of 4 USER INTERFACE: SYSTEM RESET (lamp test) DRILL . Built-in DACT (Digital Alarm Communicator/Transmitter).• Integral 80-character LCD display with backlighting and keypad. Terminal Blocks Real-time clock/calendar with automatic daylight savings AC Power - TB1: adjustments. . MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, ANN-BUS for connection to remote annunciators. 1.00 A. Audible or silent walk test capabilities. MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, Piezo sounder for alarm, trouble, and supervisory. 0.54 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, Controls and Indicators 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20 A. LED INDICATORS FIRE ALARM (red) Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. SUPERVISORY (yellow) Supervised, nonpower-limited. TROUBLE (yellow) Battery (sealed lead acid only) - J12: . AC POWER (green)• Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC ALARM SILENCED (yellow) @ 1.4 A. Supervised, nonpower-limited. CONTROL BUTTONS - Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries .. ALARM SILENCE. require separate battery box such as the BB-26 or BB655.] Top T1'Depth =5 207 (13.23 cm) Door = 16.821" (42.73 cm) Backbox = 16.65" (42.29 cm) Depth = I Door = 19.26" (48.92 cm) Backbox = 19.0" (48.26 cm) H Left Side Right Side Bottom Cabinet Measurements Page 2 of 4— DF-52416:D • 07/26/2010 Minimum Battery Size: 7 AH, Initiating Device Circuits - TB4 (and TB 6 on MS-i OUD-7 only): Alarm Zones 1 -5 on TB 4 (MS-5UD-3 and MS-10UD-7). Alarm Zones 6 - 10 on TB6 (MS-i OUD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. End-of-Line Resistor: 4.71K ohm, 1/2 watt (P/N 71252 UL- listed). Standby Current: 2 mA. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. - Notification Appliance Circuits - TB5 (and TB 7 on MS- 1OUD-7 only): Four NACs Operation: Style Y(Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) Max. Wiring Voltage prop: 2 VDC Refer to the Fire-Lite Device Compatibility Document for com- patible listed devices. Form CRelays - T138: Relay I (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - TB2: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-i OUD-7E: Same as above with 240 VAC FLPS-7. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primart and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 for more information.) lPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: V Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- 7(E) main circuit board and to _J7 on the MS-110UD-7(E). - NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPATIBLE ANNUNCIATORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) ANN-LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) dress panel. Red. (For white, order ANN-LED-W. ANN-RLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-52416:D • 07/26/2010 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Annunciators ......................................................................8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.OA MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UP-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. - Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26 (48.92 cm.) high x 16.82 (42.73 cm.) wide x 0.72 (1.82 cm.)- deep. Backbox: 19.00 (48.26 cm.) high x 16.65 (42.29 cm.) wide x 5.25 (13.34 cm.) deep. Trim Ring (TR-CE): 22.00 (55.88 cm.) high x 19.65 (49.91 cm.) wide. Shipping Specifications Dimensions: - 20.00 (50.80 cm.) high - 22.5 (57.15 cm.) wide - 8.5 (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-I0UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:0214 MEA: MEA: 333-07-E NOTE: For ULC-listed models, see DF-60440. NFPA Standards The MS-5UD-3(E)- and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterilow and Sprinkler. Supervisory). - AUXILIARY (Automatic, Manual and Waterfiow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterfiow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterfiow). - CENTRAL STATION (Automatic, Manual and Waterfiow, - and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ITIGINEMINS I MANUFACTOMNS All specifications are subject to change without notice. DUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4- DF-52416:D • 07/26/2010 A Tyco International Company 3G technology' from DSC! I Features That Make a Difference Uses HSP4 (3G) network for high-speed, reliable and low- cost communications to an IR; receiver Automatically switches to 2G (EDGEIGPRS) if 3G servic&is' -:nJt available I Compatible- with control panels that communicate using the ;Contact ID format Full event reporting 4 on-board' inputs 4on-board'outputs (open collëdtor) SIM card (included) Activaticn and initialization via -automated telephone activation sys:ehi (VRU), web-user or mobile interface provided by C24 Comrrunications PTM (Pane Transmission Monitor) switches from PSTNI to cellular cn unsuccessful - -commUnictionaftempts - Cornpatiblc with Sur-Gard® 'ISystem I/Il/ill/I V monitoring - -station receivers - Includes UL listed power - supply, trarsformer and 7 Ah rechargeable battery :ijL 864 Iiisted - CSFM listed The 3G3070CF connects the alarm control panel to the HSPA retv'ork and reports alarm signa.s d rec:ly to a monitoring station receiwer (Sur-Gard System I/Il/hIlly). The 3G3070CF uses the HSPA network to ensur3 l:ow- cost, high-speed and rel'ab e a arm communications and is compatible with control pane13 that communicate using the Contact ID formal. The 3G3070CF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 - Edition. It can be used in Fire Monitoring applications as a single communications technologi, in which case any failure of the communications path s-all ce annunciated at the supervising station within 5 minutes of the failure-, or it can be used as part of a multiple communications technologes :for example in conjurction itb a DACT). When used as a back-up provision shall be made to monitor the irtegrity of each communication path aid failure of any communicatiois path shall be annunciated at the supervising station and at the p -otected premises within not more Than 24 hours of the failure. How it Works Tie 3G3070CF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 333070CF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send The alarm across the HSPA network immediately. When being used as a backup the communicator assesses The- connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the HSPA network to the monitoring station. hstances where the control panel does not support Contact ID, the 3_33070CF has inputs pre-set to treismit fire alarm, fire supervisory or sYstem trouble. A Tyco International Company Alarm signals are transmitted directly without the need of a clearinghouse to the IF linecard of the monitoring station receiver (Sur-Gard® System l/ll/IlI/IV). I I Activating & initializing the unit Activating and initializing the 3G3070 can be done using the automated telephone activation system (JRU), mobile interface or web-user interface provided by CONNECT 24. No special tools are required. UL Listing The 3G3070CF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator the 3G3070CF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a backup communicator the 3G3070CF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G3070CF has been approved by the California State I Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Rate • Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. Ordering Information: 3G3070CF-USA ..... Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) .Specifications Dimensions ................................................ 11-1/2 x10 x3 (29.2 cm x 25.4 cm x 7.62 cm) Input Voltage.............................................................120 VAC Current Draw ................................................................ 300 mA Operating Environment ................0° to 48° C (320 to 120° F) Weight ......................................... . .................. 12.8 lbs (5.8 kg) '3 RM-2 ReIaModuIe I . Installation Instructions The is us~asan-of-line (EOL) power supervision module for I .4-wire smoke detectors. The RM-2 is used with the Polarity Reversal Module PRM- 4W and DSC FSA-410 series smoke detectors. When the PRM-4W reverses polarity on the smoke detector loop to activate all smoke detector sounders, the RM-2 Relay v'ill continue to operate normally (regardless of I input power polarity). Refer to the PRM-2W!4W Polarity Reversal Module Installation Instructions Technical Specifications: I Operating Voltage Range: ............................................................. 1OVDc to 30VDc Relay Contact Rating: ...................................................................... 2A@30VDcNAC CurrentRating: .............................................................................................. 25mA I . Operating Environment: ......................................... ............ .0°C -49-C (32°F - 120°F) ..................................................................................5% - 93% RH (non-condensing) Size (H x W x D)....................................28.5 x 86 x 21mm! 1 1!8 x x /8 in. I . Terminal Wire Gauge: ............................................ ................................. 14-22 AWG Connection Diagram Run the connection wires through the wiring holes on the back of the unit. I Mounting To mount the unit, remove the plastic cover and secure the unit to the desired loca- tion with the screws provided. Replace the cover. I The module can also be mounted inside a standard 4" electrical box (1.5" deep) if required by the installation. Please refer to the diagrams below: 4-WIRE SMOKE DETECTORS PRM-4W Polarity Reversal Module '1 - 12 FSA-410 Series 4-wire Smoke Detector Control Panel ZxCom ++ NO _ I. I Ivy— Panel EOLR _BLK uI11I Eli 0 NC RED-1 ct . I;? I I COM DSC RM- 2 Relay i i NO Mounting of the Relay in an Electrical Box 4-Wire Smoke Detector FSA-41 Ox Smoke Detector Mounting Plate Power Supervision Relay RM-2 Electrical Box (1.5" deep) LIMITED WARRANTY Digital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the product shall be free of defect in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or improper application of the equipment. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether. expressed or implied and of all other obligations or liabilities on the part of Digital Se- curity Controls Ltd. This warranty contains the entire warranty. Digital Security Controls Ltd. neither as- sumes, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. In no event shall Digital Security Controls Ltd. be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product. WARNING: Digital Security Controls Ltd. recommends that the entire system be completely tested on a reg- ular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electri- cal disruption, it is possible for this product to fail to perform as expected. ©2003 Digital Security Controls Ltd. III Viii iIIlIIIiiiii III Toronto, Canada • www.dsc.com Printed in Canada 29034640R002 Direct all comments concerning this publication to pubs@dscltd.com Th SYSTEM $ SENSOR .' Photoelectric Smoke Detectors System Sensor's J3" series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Installation ease. The Eline redefines installation ease with its Plug-in detector line, mounting base included plug-in design.—his allows an installer to pre-wire the bases included with the heads. The large wire entry port and in-line terminals Large wire entry port provide ample mom for risatly routing the wiring inside the base. In-line terminals with SEMS screws The base accorr modates a variety of back box mounting methods, Mounts to octagonal and single-gang backboxes, 4-square as well as direct mountinc with drywall anchors. To complete the - hackboxes, or direct to ceiling installation, il heads plug Li to the base with a simple Stop-Drop 'N Lock action. - Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Intelligence. P detectors offer a number of intelligent features Built-in remote maintenance signaling - to simplify testing and maintenance. Drift compensation and smoothing alga-ithms are standard with the i3 line to minimize Drift compensation and smoothing algorithms nuisance alarms. Two-wire P detectors needing cleaning can Simplified sensitivity measurement generate a remote maintenance signal, when connected to the Wide angle, dual color LED indication 2W-MOD2 looptest/mairi:enance module, or to a panel equipped with the P protocol. This signal is indicated by LEDs located at the Loop testing via EZ Walk feature module and the panel.TLe SENS-RDR, a wireless device, displays the Built-in test switch sensitivityof i3 detectors in terms of percent per-foot-obscuration. Instant inspection.The il series provides wide-angle red and green LED indicotors for irstant inspection of the detector's condition: normal standb9, out-of-sensitivity, alarm, or freeze trouble. When connected to the W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on twc -wire P dotectors. This feature verifies the initiating loop wiring by providing ED status indication at each detector. Agency Listings I ® Zf3 MEA MSFM LISTED APPROVED approved approved 5911 1 3011446 7272-1209:210 290-01-0 2093 (-j) Smoke Detector Specifications Ul Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, Out of sensitivity, alarm, and freeze trouble (Model WT-13, 4W1-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24Vnon-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average ôo 0SO Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 160 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Physical i.i. Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight . 6.3 oz. (178 grams) . Operating Temperature Range 2W-B and 4W-B: 327-1 20°F (0°C-49°C); 2WT-B and 4WT-B: 327-r1 00°F (06C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4VVT-B only: 41°F (5°C) Sensitivity 2.50/o/ft. nominal lnputTerminals 14-22AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power Up Sequenc PIIn FFTTE,II LED Mode Green LED Red LED Condition . Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off . Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information —V11i.i.(Alarm u 2W-B No 2-wire 130 mA max. limited by control panel 2VVT-B Yes 2-wire 130 mA max. limited by control oanel 4W-B No 4-wire 20 mA @ 12V, 23mA @ 24V 4\NT-B Yes 4-wire 20 mA @ 12V, 23mA @ 24V Accessories 2W-.MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter C2116 System se—r I 5 ...5'7!b1 3825 Ohio Avenue. St. Charles, IL 60174 0"t 5Y~1MWh-1.Mf.1 Phone: 800-SENSOR2 - Fax: 630-377-6495 A05 0318-006. 7/06 - 41;676 I EIEI R10 R8 R6 R4 R2 0 0 Relay Module The ROME (Relay Option Module Enclosure, red) and ROME-B (black) is shipped with one ANN-BUS Relay Module already installed. The ROME Series provides mounting space for one additional Relay Module or one addressable Multi- Module. Relay Module The Relay Module provides 10 programmable Form-C relays when used with a compatible FACP (Fire Alarm Control Panel). This document is provided as a quick reference. For more detailed programming information, refer to the appro- priate-FACP installation manual. Relay Module Specifications Operating Voltage - 24 VDC Max. Current @ Alarm 75 mA 24VDC Standby 15mA Operating Temperature 32° to 120° F (0° to 49° C) Max. Wiring Distance from FACP 1,250 ft. (380 m) (with 12 AWG wire) 2 amps ©3OVDC (resistive) Relay Contact Ratings 0.5 amps @ 30 VAC (resistive) Indoor Use in Dry Location Only Relay Designations and Terminals The relay numbers and terminal designations are illustrated in the following illustration. ANN-BUS TBI 0 LI BA+ -ANN-BUS TB6 jj~ NO NC Ell NO NC E E TB3r C Relay Module Normally Open, Normally Closed and Common terminals for each relay follow the same pattern as illustrated above. Wiring the Relay Module to an FACP Refer to the following table and illustration for wiring connections. All connections/sources are to be power-limited and supervised. 12 - 18 AWG (0.75 - 3.25 mm 2) wire for 24 VDC circuit is acceptable. Refer to the appropriate FACP manual. Power wire distance limitation is set by 1.2 volt maximum line drop from source to end of circuit. Maximum distance from FACP to last ANN-BUS device must not exceed 1,250 feet (380 m). Refer to Wiring Distance Table in appropriate FACP manual for wire gauge and distance limitations. Relay Terminals (TBI) FACP ANN-BUS Terminals Terminal 1 (B) B (ANN-BUS) Terminal 2 (A) A (ANN-BUS) Terminal 3 (+) (+) Terminal 4 (-) (-) B (ANN-BUS)i A (ANNBUS)1Connect to FACP ANN-BUS and/or next device + (24 VDC)1 - (GND) jConnect to FACP or next device 0 TBI0 B A + 0 ANN-BUS TB6 HLILI Relay Module Setting Relay Module DIP Switches Each ANN-BUS device requires a unique address. Relay Module DIP switch SW1 is used to set the address for the mod- ule. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. ANN-BUS device addresses do not need to be sequential and can be set to any number between 01 and 08. Note that 00 is not a valid address. The following illustrates the DIP switch settings for each address (ID Number): DIP Switch SWI 11171117FIM ID Number 00 01 02 03 04 05 06 07 08 (Address) (not valid) 2 ROME Series Installation Document— P/N 53530:B 9/14/2009 Mounting an Optional Second Relay Module in the ROME Series ANN-MBRLY Mounting Bracket Installation An optional second Relay Module can be mounted inside the ROME Series using the ANN-MBRLY mounting bracket. Two holes must be drilled in the enclosure to secure the ANN-MBRLY as described in the following steps: Place the ANN-MBRLY mounting bracket flat against the inside back wall of the ROME Series, while positioning two oblong holes over the mounting studs as shown in the following illustration. Make a mark on the ROME Series back wall using the two holes that will be used to secure the ANN-MBRLY as a guide. Remove the ANN-MBRLY from the ROME Series and drill two 3/32" (dia. 0.093") holes in the locations marked in step 2. Note that these holes will be used to secure the ANN-MBRLY using the two supplied self-tapping screws. Place the ANN-MIBRLY mounting bracket oblong holes in position over the mounting studs and install the two supplied nuts, but do not tighten at this time. Install the two supplied self-tapping screws in the locations indicated and secure the ANN-MBRLY to the ROME Series using the holes drilled in step 3. - Tighten the two nuts installed in step 4. - f0 self-tapping screw ,mounting stud oblong mounting (with nut) o TB1 0 TB6 drill 3/32" (dia. 0.093") 0 hole in ROME Series for _______ - self-tapping screw T. ANN-MBRLY Mounting Bracket TB5 MOM IT. 0 jrIB2 drill 3/32" (dia. 0.093") bl hole in ROME Series for 0 self-tapping screw 0 0 0 ® 0 oblong mounting hole mounting stud self-tapping screw (with nut) ROME Series ROME Series Installation Document - P/N 53530:B 9/14/2009 3 BA. ANN-BUS TB6 U TB3 TB5 LiU Li 11 TB4 T:2 o 0 . '-0. ® 0 ' mounting hole 0 0 .Relay Module Installation on ANN-MBRLY Mounting Bracket Hold the Relay Module with the relays positioned to the left and install the Relay Module on the ANN-MBRLY mounting bracket by positioning the four module mounting holes over the four standoffs on the mounting bracket. Secure the Relay Module to the .ANN-MBRLY mounting bracket with the four supplied, screws. Set the SW DIP switches and connect the wiring as described in the previous sections. mounting hole 0 ITf32 1 UI Li I ITB4 - Optional n Li Li' Relay Module lBS TB3 HL TB6 ANN-BUS . +AB flTBI . 0 nounting hole mounting hole ROME Series 4 . . ROME Series Installation Document - P/N 53530:B 9/14/2009 Mounting an Addressable Multi-Module in the ROME Series MULTIMOD-BRKT Mounting Bracket Installation An addressable Multi-Module communicates with the FACP via the SLC loop. A Multi-Module can be installed inside the ROME Series enclosure using the MULTIMOD-BRKT module mounting bracket. Install the MULTIMOD-BRKT as described below. Place the MULTIMOD-BRKT mounting bracket flat against the inside back wall of the ROME Series, while positioning two oblong holes over the mounting studs as shown in the following illustration. Make a mark on the ROME Series back wall using the two holes that will be used to secure the MULTIMOD-BRKT as a guide; Remove the MULTIMOD-BRKT from the ROME Series and drill two 3/32" (dia. 0.093") holes in the locations marked in step 2. Note that these holes will be used to secure the MULTIMOD-BRKT using the two supplied self- tapping screws. Place the MULTIMOD-BRKT mounting bracket oblong holes in position over the mounting studs and install the two supplied nuts, but do not tighten at this time. Install the two supplied self-tapping screws in the locations indicated -and secure the MULTIMOD-BRKT to the ROME Series using the holes drilled in step 3. 6. Tighten the two nuts installed in step 4. self tapping screw 8 oblong mounting hole \ mounting stud (with nut) o TBI 0 0 ANN-BUS T86 drill 3/32 (dia. 0.093) hole in ROME Series for ° self-tapping screw T. MULTIMOD-BRKT Mounting Bracket LI TB4 TS drill 3/32" (dia. 0.093") - hole in ROME Series for C 0 self-tapping screw 0 a ,0 V self-tapping screw o mounting stud long mounting hole (with nut) ROME Series ROME Series Installation Document— P/N 53530:B 9/14/2009 5 7. Install the supplied module insulating pad on the MULT1MOD-BRKT bracket by aligning the four outer holes with the four standoffs on the bracket and pressing the pad onto the standoffs and flat against the bracket as illustrated below. standoff standoff standoff 0 standoff Install the addressable Multi-Module on the MULTIMOD-BRKT mounting bracket by positioning the four module mounting holes over the four standoffs on the mounting bracket. Secure the addressable Multi-Module to the' MULTIMOD-BRKT bracket with the four supplied mounting screws as illustrated below. • mounting screw , b 0 • P ® --- c ounting screw U U • - 00- O-.'O 0 0 o • Q O 0 U Umom n 1 ,.mounting screw O 0 0 0 1 0 0 - U77 ..L.. L.. _.L. ®D 0 0 mounting screw 0 6 ROME Series Installation Document - P/N 53530:B 9/14/2009 pOTTER CF/CR Series - The Symbol of Protection Conventional Heat Detectors Features Standard and moisture-proof versions available I . Low profile design White plastic housing (standard versions only) Open or closed contact versions available Available in single or multiple circuit versions f Product Includes a 5 year warranty I I Model CR-135W Model CR-I 35MP - LISTED 7270-1110:0100 S2406 Description The CF/CR Series includes standard heat detectors as well as specialty versions for hazardous or moisture-proof -applications. Each detector is available in single or multiple circuits with open, and/or closed contact configurations. CF/CR Series detectors are available in 135°, 165°, 200°, and 285° Fahrenheit versions. CF Series The CF Series detectors are Fixed Temperature only. They will operate when the detector reaches the applicable temperature. Fixed Temperature detectors are non-restorable. CR Series The CR Series detectors are combination Rate-of-Rise and Fixed Temperature. The Rate-of-Rise function allows the detector to operate when the temperature at the detector increases at a rate of 15°F per minute. The Fixed Temperature portion will cause the detector to operate when it reaches the applicable temperature. The Rate-of-Rise portion of the detector is restorable; however the Fixed Temperature portion is non-restorable. MP Versions Both the CF and CR detectors are available in MP (modified pigtail) versions for enhanced protection against moisture-laden environments. A CAUTION All wiring must be installed in compliance with the local electrical code using approved cable, AWG 18 minimum. Begin electrical connections by stripping approximately 1" (2.5 cm) from the end of each wire. Insert the stripped end into the wire-retaining hole in the terminal bar, wrap clockwise around the terminal screw, and tighten. Circuit wiring must be broken at each terminal to ensure proper supervision. Technical Specifications Dimensions..5.25" x 2" Device Weight 0.41 lbs (0.19 kg) Shipping Weight 0.6 lbs (0.3 kg) Materials Standard Detectors - Plastic MP Detectors - Aluminum 3 Amps at 125VAC Contact Ratings I Amp at 28VDC 0.3 Amps at 125 VDC Environmental 'AOJ JU '.. f ,/'r'O\ uIO1' (1 UUIO - U Limitations Exclusive of Operating Temperature Mounting 4" Octagon Backbox Potter Electric Signal Company, LLC St. Louis. MO • Tech Support: .866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8840004-REV Q • 10/14 • PAGE 1 OF 2 (E)POTTER I a The Symbol of Protection CF/CR Series Conventional Heat Detectors Installation Wiring Diagram Mounting Fire Alarm Control Panel Devices mount on a 4" octagon backbox. The provided mounting ring covers wall imperfections. Engineering Specifications I Thermoflex® Model CR Series Automatic Rate-of-Rise Heat Detectors shall be installed in areas where ambient temperatures do not exceed 100°F. In areas where ambient temperature is above 100°F but will not exceed 150°F, specify CR-I 65 unit. If ambient temperatures exceed 150°F, specify CR-200 or CF-285. In areas where sudden increases in ceiling temperature are normal, specify fixed. temperature only units, with fusable settings of 135°F, 165°F I 200°F, or 285°F. The rate-of-rise operation responds to temperature increases of 15°F (8.4°C) per minute. Thermflex® detectors shall be installed in areas where environmental conditions including dust, vapors, insects, etc. would cause an ionization or photoelectric type detector to initiate a false alarm. Ordering Information Model Description . Stock Number Operating Tempurature Maximum Installation . Tempurature Spacing* CR-135W Fixed/ROR. Indoor .1000140 135°F (57°C) 100°F (37.8°C) 70' (21rn) CR,165W Fixed/ROR, Indoor 100.0122 165°F(71°C) 140-F (60-C) 70'(21rn) CR-200W Fixed/ROR, Indoor 1000141 200°F (93°C) 160°F (71°C) 70'(21m) CF-135W Fixed, Indoor 1000142 135°F (57°C) 100°F (37.8°C) 40' (12m) CF-165W Fixed, Indoor 1000121 165-F (71-C) 140-F (60-C) 25'(7.5n) CF-200W Fixed, Indoor 1000143 200°F (93°C) 160°F (71°C) 25'(7.5m) CF-285W Fixed. Indoor 1000152 285°F (140°C) 225°F (107.2°C) 25' (7.5m) CR-135MP i7oi Outdoor 1000137 135°F (57°C) 100°F (37.8°C) 70' (21m) CR-165MP 'Pe OR, Outdoor 1000162 165°F (71°C) 100°F (37.8°C) 70' (21 m) CR-200MP Fixed/ROR. Outdoor 1000139 200°F (93°C) 150°F (65.6°C) 70' (21m) 15MP Fixed, Outdoor 1000136 135°F (57°C) , 100°F (37.8°C) 40' (I 2m) -200MP Fixed, Outdoor 1000138 200°F (93°C) 150°F (65.6°C) 25(7.5m) CF-285MP Fixed, Outdoor 1000125 285°F (140°C) 225°F (107.2°C) 25' (7.5m) * Assumes a flat, uninterrupted ceiling at a height not exceeding 10'/3m For closed circuit versions. add a"C"tomodel (forexampte: CF-135CW. CR-I35CW, etc.) 5- For dual circuit versions, add a "2" to model (for example: CF-1 35-2-W,,CR-1 35-2-W, etc.) 0 For other available models contact customer service Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com ISO 9001:2003 1 DESIGNING, MANUFACTURING, ' & DISTRIBUTING QUALITY SYSTEMS 8840004-REV Q 10/14 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7165-0075:0214 Page 1 of 1 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reyn @Honeywell.com DESIGN: Model MS-5U -3, MS-5U 4E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-i OUD-3, MS-10UD-3 , MS-lOUD- MS-i OUD-7C AND MS10-UD-7E Fire alarm control units. The MS-5UD ser s has fly put zones and the MS-lOUD series has ten input zones. Both product lines ur notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. Refer to listee's data sheet for detailed product description' and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: 'Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. - 04-23-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: • July 01, 2014 Listing Expires June 30, 2015 I AuthOrized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7300-1273:0140 Page 1 of 1 CATEGORY: 7300 FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security ControIs95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com - I DESIGN: Model 3G3070-CF, RF communicator (GSM-GPRS or 3G/HSPA network) signaling device. It is intended for use as a standalone communication technology (standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. It is used for I central station fire and burglar alarm system communication, which employs a GSM-GPRS or 3G/HSPA (cellular) communication as its signaling medium. This product is to be connected to a listed control panel in accordance with the installation instructions provided 1 with the Model 3G3070-CF transcel-vRe—r A Motorola-radio Model H24 connects to an interface board Model UA595 to frm a Model 3G3070CF communicator, which is intended to be installed at each protected pr mise. The I Model 3G3070-CF is.housed in its own metal enclosure and can connect to a separately isted unit through a telephone line connection or using its onnected to dry con ;ntroll acts ts from the fire alarm control m, supervisory, or trouble eet for additional detailed product description and operational I considerations. RATING: 120 V, 50/60 Hz, 0.3 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. I APPROVAL: Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. 02-09-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 . Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1273:0127 Page 1 o 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 7 0 (905) 760-3020 I Email: dnitatycoint. DESIGN: - Models PRM-2W 2WC for 2-wire o detector , PRM-4W, -4WC(for 4-wire smo - 3 detectors) pow reversal modul and M-2p0weJs pervision relay modules. Refer to RATING: listee's data s eet for additio detail .d-pfdt-6 cription and operational considerations. I_ INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. I APPROVAL: -Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: 1 I I. I I I I ,- 09-30-03 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: I Authorized By July 01, 2014 Listing Expires June 30, 2015 JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - I . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 —SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 I Email: trish.linhart@systemsensor.com DESIGN: Models 2W-13, 2W1-B, 4W-B and 4W1-B photoelectric type smoke detectors. Model 2W- - and 2WT-B are 2-wire and model 4W-13 and 4WT-B are 4-wire detectors. Models 2 - nd. I 4WT-13 employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. I RATING: 8.5 - 35 VDC . . INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. I . APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 I Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0222 Page 1 of 1 CATEGORY: 7120 —ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.ReynoIds2Honeywell.com DESIGN: Models ANN-LED, ANN-RLED Remote Annunciators, and ANN-RLY Relay Module. Models ANN-LED and ANN-RLED provide remote annunciation of up to 10 inputs (ANN-LED) and 30 inputs (ANN-RLED). Model ANN-RLY relay module provides 10 programmable Form C relays. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as annunciators or relay module for use with listee's separately listed fire alarm control units. Refer to Manufacturersinstallation Instruction Manual for details. NOTE: 04-16-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 3O,2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division