Loading...
HomeMy WebLinkAbout3125 LIONSHEAD AVE; ; FPC2023-0189; PermitIi1iriii1ii 1:111:41 tity of Carlsbad Print Date: 11/18/2024 Job Address: 3125 LIONSHEAD AVE, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2218801800 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check 4*: Permit No: FPC2023-0189 Status: Closed - Finaled Applied: 11/07/2023 Issued: 12/13/2023 Finaled Close Out: 05/09/2024 Final Inspection: INSPECTOR: Cheung, Nathaniel Project Title: Description: RACEWAY INDUSTRIAL - REVISED PLANS FOR SPRINKLER MONITORING SYSTEM (18 DEVICES) (REV. 1: WIRE CHANGE & LARGE ALARM CONTROL PANEL CHANGE) (E-REVIEW) Applicant: FPContractor: CHULA VISTA ALARM INC CHULA VISTA ALARM INC JAMES RODRIGUEZ 6175 PROGRESSIVE AVE, 4* STE 400 1105 CLOUDWALK CANYON DR SAN DIEGO, CA 92154-6649 CHULA VISTA, CA 91911-6835 (619) 585-9111 (619) 585-9111 FEE AMOUNT FIRE Plan Review (per hr - Regular Office Hours) $170.00 FIRE Reinspection (per Inspection) $242.00 FIRE Reinspection (per Inspection) $242.00 FIRE Sprinkler Monitoring System $482.00 Total Fees: $1,136.00 Total Payments To Date: $1,136.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov PROJECT: Raceway Industrial Building Shell Construction 3125 Lionshead Avenue Carlsbad, CA 92008 SYSTEM: SPRINKLER MONITORING SYSTEM INSTALLATION SUBMITTED BY: CVA Security 6175 Progressive Avenue Suite 400 San Diego, CA 92154 PHONE: (619) 585-9111 DATE SUBMITTED: November 6, 2023 Potter IPA-60 Fire Alarm System Equipment NEW EQUIPMENT LIST Model # Description Mfg. CSFM# IPA-60 Fire Alarm Control Panel Potter 7165-0328:0500 UD-2000 DACT Module Potter 7300-0328:0515 TG-7FS Cellular Communicator Telular Corp. 7300-1402:0109 BW-DOCBOX Document Cabinet Mier N/A PAD300-PD Photoelectric Smoke Potter 7272-0328:0541 Detector PAD300-613B Smoke Detector Base Potter 7300-0328:0539 PAIOO-PSDA Manual Fire Alarm Box Potter 7150-0328:0201 (Manual Pull Station) PAD100-SIM Single Monitor Module Potter 7165-0328:0500 PAD 100-DIM Dual Monitor Module Potter 7165-0328:0500 PADIOO-NAC Addressable NAC Module Potter 7165-0328:0500 P2RK Exterior Horn Strobe System Sensor 7125-1653:0188 Central Station UL Certificate of Compliance (E)POTTER The Symbol of Protection Features 60 addresses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class A or Class B for SLC, P-Link and NACs 5 Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at I Amp each, ideal for manual release and abort Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event History Buffer Cabinet will house up to 18 AH batteries Optional two line DACT with UD-2000 that can report General, Zone or Point Information Built in IP Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information Product includes 5 year warranty. UUKL Listed for Smoke Control Description The IPA-60 is an analog/addressable releasing fire alarm system with a total system capacity of 60 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The TPA-60 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the 1/Os are rated at lAmp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The 1/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA-60 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-1000 may be used to extend releasing capability. The NACs may be expanded using the PSN-l000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the IPA-60 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit Fire Alarm ContTPóëi <a> APPROVED LISTED Technical Specifications Dimensions 16"W x 17"H x 3 '/s"D AC Mains 3.0 Amps @ 120 VAC 50/60 1-12 2.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current- 130 mA Alarm Current-200 mA 5 Amps power for NACs, I/O, and P-Link Battery 3 Amps per NAC, regulated I Amp per I/O circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of I Amp Temperature and 32° to 120° (0°C to 49°C) with a maximum Humidity Range humidity of 93% non-condensing. NFPA 12, I2A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Sta- tion (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Standards Automatic (A), Manual (M), Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev P01), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 connections. Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 10F4 (E)POTTER The Symbol of Protection (!PA6O) Fire Alarm ConfrTP-âJiël' SLC Loop Accessories The control panel may be connected with up to 60 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD! 00.PHD Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector. PAD IOO-HD Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F. PADIOO-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD 100-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PA.D100-413 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD I00-113 Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD 100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125 VAC. PAD 100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD 100-CD Addressable CO gas detector. PADIOO-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD! 00-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) PAD I 00-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Modules Device Description PAD 100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD 100-PSSA Single Action Addressable Pull Station. PAD I 00-PSDA Dual Action Addressable Pull Station. PADlOO-SlM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD loO-TRTl Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PADiOO-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PADIOO-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD loo-IM Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD loo-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125 VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD 00-SM Speaker Module provides switching for two audio channels. PAD I 00-LEDK Addressable LED and key switch that mounts in a single gang box. PADl00-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD I 00-OROI One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 2OF4 (E)POTTER IPA-6O The Symbol of Protection Fire Alarm CiiFoTPaffe/ SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green Alarm - Red Earth Fault - Amber Supervisory - Amber Silenced - Amber Trouble - Amber Pre-Release - Amber Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The IPA-60 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: RA-6075R - 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) - 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the IPA-60 as releasing circuits. CA-6075 - Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 - UL listed, Dual line telephone alarm communicator DRV-50 - LED driver expander, used to connect up to 50 LEDs in a graphic display FCII-1000 -Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 - Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three IPA series panels to share a single reporting technology. IDC-6 - Initiating device circuit provides 6 programmable inputs AE-2 - Two card expansion cabinet AE-8 - Eight card expansion cabinet AE-14 - Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA-60 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 3OF4 (E)POTTER The Symbol of Protection ('A-6O Fire Alarm Con fr1Pã,1' Dimensions of TOP • DEPTH =3.75 o DOOR= 16.07 BACKBOX = 15.77 DEPTH =3.84 LEFT SIDE RIGHT SIDE BOTTOM Ordering Information Model Description Stock No. (IPA-60) Fire Alarm Releasing Control Panel 3992714 Replacement Board IPA-60 3992738 DWG #593.1 Compatible Releasing Devices Note: For releasing applications please order the Potter FOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 7321811N4UNLVN0C112CZ 732 I2BN4TNLVNOC322C2 Victaulic 753-E Series Mini Max MX 123 & MX200 wl 8876677 & 889323 Viking 11591, 11601, 11602, 13843,& 13844 TLX PA0036 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 . www.pottersignal.com 8830101-REVG • 9/19 PAGE 4OF4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: CATEGORY: 17165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timd(pottersicinaI.com DESIGN: Models tiPA6O IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU),, proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 IRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module JPAD 100-LEDK LED Key Switch Module I PAD 1 00-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *sLCE..127 Loop Expander Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTES: I i 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2012 (E)POTTER (uD-2qq) The Symbol of Protection Digital Alarm Communicator Features Allows for communication to Monitoring Station Communicates using SlA-DCS or Ademco Contact ID Protocols For use with IPA, AFC, and ARC series Addressable Panels and PFC-4064 Conventional Panel Status LEDs indicate operation of DACT card Installs with ease behind main panel LCD display via User Interface bracket Device address is set internally to address I Includes two (2) RJ45 phone cords <~> 0 & LISTED Description The UD-2000 Digital Alarm Communicator Transmitter (DACT) provides for up to two (2) phone lines for communication to a monitoring station. The UD-2000 communicates using the SIA- DCS or Ademco Contact ID protocols. When enabled, the DACT automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the communication is complete, the DACT will hang up. The DACT is provided with terminal blocks for each phone line and two RJ45 cords. In order for the DACT to work properly, it must be installed on a plain old telephone service (POTS) line or equivalent deemed by the authority having jurisdiction. The DACT must be installed before any other equipment to ensure it can seize the phone line. Phone lines are high voltage and should be run in a separate conduit from other circuits. The wire conductors connecting the DACT to the phone system should be 26 AWG or larger. Technical Specifications Operating Voltage 22.0-24.0V Standby Current I 6mA Alarm Current 23mA Max UD-2000s per panel I Dimensions 4"W * 6"H * 1-5/8"D Operating Tempuratures 0°C - 49°C (32°F- 120°F) Operating Humidity Range 10% - 93% @ 30°C (86°F) (non-condensing) Mounting Options In FACP Behind keypad Shipping Weight 0.47 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 I Customer Service: 866-572-3005 www.pottersignal.com 8830146- REV B • 6/19 PAGE IOF3 (E)POTTER The Symbol of Protection (UD-2OO) Digital Alarm Communicator RJ3 1X Phone Jack to UD-2000 Plain Old Telephone (POTS) lines Out to Premises Phones Tip (Brown) (Grey) Out to Premises Phones I 1 11 gc) I I I-Grey r7* 2-Tan i 3-Black I 4-Red J;J 5-Green 111111111111 ,-... IIIIUIIIILIUI I I 6 - Yellow I 7-Blue II I 8-Brown Tip (Green) Line In From Telco Tip (Green) Ring (Red) Line In From Telco 2 Ic 1 Ring UD-2000 Communicator Telco Tip = Red Telco Ring = Green Phone Tip = Brown Phone Ring = Grey Installation The UD-2000 DACT is connected to the control panel using the provided four-wire cable connection (PIN 5210514) between P4 and UD-2000 P1. The connection is power limited and supervised. Power system down. Slide the UD-2000 into the card guides located under the User Interface bracket. Secure the UD-2000 to the User Interface bracket using the provided #6-32x3/8" screw Install the provided four-wire conductor jumper between UD-2000 P1 and P4. Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830146- REV B • 6/19 PAGE 2OF3 P Connector on main board P Connector on small platform control panel Slide, in guides under rnain board. (E)POTTER The Symbol of Protection U D-2000 Digital Alarm Communicator UD-2000 DACT Installation on UD-2000 DACT Installation on Small Platform Panel Large Platform Panel Fig 1 Fig 2 Ordering Information Model Description Stock No. (UD-2000) Digital Alarm Communicator 3992769 Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830146- REV B • 6/19 PAGE 3OF3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 17300-0328:0515) CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timd@pottersignal.com DESIGN: Models UD-1 000 and *-200O Digital Alarm Communicator Transmitters (DACT). 1Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as a digital alarm communicatior for use with listee's separately listed fire alarm control panels. Refer to listee's Installation Instruction Manual for details. NOTES: *Rev 01-09-19 gt TI This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 TG-7FS LTE-A P/N: TG7LAF01 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS T E LG UA RD COMMERCIAL FIRE PRODUCT FEATURES - Certified for use on the AT&T LTE network for long, sunset-free installation. 1- Meets UL 864 requirements for sole, primary or backup path communications. - Minimizes false alarms by providing dual paths for self-tests. I- Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LTE-A can serve as the sole communications path for the fire alarm system. It ' replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new sixty minute supervision mode. The TG-7FS LTE-A can also be installed as a backup path and upgraded to sole path at a later date. *L JA 2.L1? TE LG UA RD TG-7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS r Power Radio Transceiver LTE Bands: 2, 4&17. 3GBands 2&5 ' Antenna: 9' dipole with.,rnax gln of3dBi FCC part95 22t 24 27 and8 compliant. Physical Details Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. UL Listings I Commercial Fire j864 • control units & accessories for fire alarm systems ULC Listings 5545 Canadian household fire warning systems S304 Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems For the most current product specificahots and UL Listings visit www.Telguaid.com. SECURITY SIGNALING ONIC TY C®US NFPA /EAAsSOoATION. Connected LISTED INTERNATIONAL wi by AT&T Telguard, a Division of Telular corporation • 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA 800-229-2326, Option 5 www.Telguard.com copyright c 2017 Telular corporation • All Rights Reserved Conwnercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-1402:0109 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES ~LISTEE: TELULAR CORP. 3325 Cumberland Blvd, NE, Suite 300, Atlanta, GA, 30339 Contact: Stewart, Sean (800) 229-2326 (678) 945-1651 Email: sean.stewart@ametek.com DESIGN: Models TG7LAA02, TG7LA001, TG7LAA01, TG7LA002,ff37LKF0T TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF01, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTES: Burglary and other non-fire functions were not examined. * Revised 11-27- 19 gt Pagel of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/24/2023 Listing Expires: 06/30/2024 Authorized By: Damon Lam, Program Coordinator Fire Engineering & Investigations Division Page 2of2 provs- BW-DocBox (15"Wx 13"Hx4"D) includes: Three labels: "Fire Alarm Documents" "As-BLliIt Permits" "Test and Maintenance Documents" An adjustable bungee allows you to fit various sizes of binders, documents, smoke-cans, etc. A door bracket holds two CDs, three sets of keys and more documents A cam lock with two keys BW-DocBox2 (11"Wx 15"Hx 4"D) Smaller and more basic model without the door bracket for CDs and key sets. However, it does have the three labels, adjustable bLingee and a lock with two keys. I see the box you want? Customization, special colors, and/or silk-screening of logos are us or visit our website available for quantities of 25 or more. (requires lead lime) RODt ( IS, / \ 1. 800-473-0213 E-mail: info@mierproducts.com (E)POTTER The Symbol of Protection Features Low profile, less than 2 inches with the base Wide selectable sensitivity range of I I to 3.50/o/foot Detector communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting, no programming tool required Magnetic test switch LED alarm indicator Product includes 5-year warranty UUKL Listed for Smoke Control UL268 7th edition compliant Description The Photoelectric Smoke Detector is a listed Analog Addressable smoke detector compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD300-PD is a low profile smoke detector with a wide sensitivity range. The detector and base are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD300-PD has a sensitivity range of 1.1 to 3.5 % per foot and is UL listed. The PAD300-PD features drift compensation and has built in dirty detector warning as well. The PAD300-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The detector is compatible with any of the PAD300 series detector bases and simply twists on. The PAD300-PD is addressed using DIP switches in the rear of the detector and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from I to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: CFPAD300-pp) PhotoelecSkëDetector 0328-0541 Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 iA Alarm Indicator 1 LED Alarm Set-point Range 1.1 to 3.5%/ft (3.6 to lI%/m) Installation Temperature Range 32 to 120 ° F (0 to 49 ° C) Operating Relative Humidity 0% to 93% (Non-condensing) range Start-up Time Max. 1 sec. Maximum Number of Addresses 127 Per Loop Maximum Number of Lighted 30 Indicators in Alarm Per Loop Color Eggshell White Weight (without base) 91g (3.20z) Dimensions (without base) Height: 1.42 in (36mm) Diameter: 3.93 in (100 mm) I. Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830216- REV B • 2/23 PAGE I OF 2 (E)POTTER (PAD3oo-PD The Symbol of Protection PhotoeleicSinökDttöF" Air Velocity Ratings The PAD300-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD300-PD will operate even though the LED may not illuminate. Operation The PAD300-PD is an analog addressable detector that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD300-PD with the PAD300-4DB or PAD300-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The detector includes an insect screen to prevent foreign objects from reaching the chamber and can be cleaned to restore operation of a dirty detector. Detector Sensitivity The PAD300-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the detector is installed over time, the detector compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty detector. The detector will then have to be cleaned or replaced. The PAD300-PD can be programmed to provide a maintenance alert prior to reaching the dirty detector level which will allow for intervention prior to the detector going into trouble. This allows for detector replacement or cleaning prior to a nuisance trouble occurs. NOTE: As required by NFPA, do not install the detectors until all construction is complete and the work area has been thoroughly cleaned. If the detectors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD300-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, 3-1/2" octagon, 3-1/2" square, double gang, 4" octagon, 4" square, 50mm c/c, 60mm c/c and 70mm c/c boxes. Device Description Stock No. PAD300-4DB 4" Detector Base 3992781 PA.1oo-6DB) 6" Detector Base 3992782 PAD300-TB 6" base with an isolator module included 3992783 PAD300-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125VAC 3992784 PAD300-SB 6" base with sounder module included. Sound pattern is provided from external source 3992785 PAD300-LFSB 6" base with 520Hz sounder module included. Sound pattern is provided from external source 3992786 Ordering Information Model Description I Stock No. (PAD300-PD) Photoelectric Smoke Detector 3992775 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830216- REV B • 2/23 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7272-O328:O4i) CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpottersignal.com DESIGN: Models PAD300-PHD and PAD300-PHD-I Multi-criteria smoke with complimentary heat detector head. Model and PAD300-PD-I Multi-criteria smoke detector head. Products are intelligent addressable photoelectric smoke detector. Model PAD300-PHD employs components for both smoke and heat detection. Model PAD300-PHD-I employs components for both smoke and heat detection along with components for circuit isolation. Model PAD300-PD employs components for smoke detection. Model PAD300- PD-I employs components for smoke detection along with components for circuit isolation. Refer to listees printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with the listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE APPROVAL: Listed as photoelectric smoke detector and photoelectric smoke detector with complementary heat detector for use with listee's separately listed compatible detector bases and fire alarm control panels. Refer to listee's Installation Instruction Manual for details. Models PAD300-PHD and PAD300-PHD-I complies with the applicable requirements in UL 268, 7th Edition and UL 521 7th Edition. Models PAD300-PD and PAD300-PD-I complies with the applicable requirements in UL 268, 7th Edition. Compatible Detector Bases: Models PAD300-4DB, PAD300-4DB-1,(PAD300-6DB) PAD300-6DB-I (CSFM No. 7300- 0328:0539) Models PAD300-SB, PAD300-LFSB (CSFM No. 7300-0328:0544) Models PAD300-I13, PAD300-RB - only for use with models PAD300-PHD and PAD300- PD (CSFM No. 7300-0328:0543) Compatible Fire Alarm Control Panels: Models IPA-60, IPA-100, IPA-4000 (CSFM No. 7165-0328:0500) Models AFC-50, AFC-100, AFC-1000, ARC-100 (CSFM No. 7165-0328:0509) NOTES: 1-27-23 DAL This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 ---'I (E)POTTE (PAD300,4DB*!) The Symbol of Protection 4 /6" Detector Base Features Terminals marked with polarity to assist with installation Duplicate Terminals for In-and-out SLC Wiring Terminals accept 22 to 12 AWG wire sizes Installs on Single Gang, Double Gang, Octagon or 4" Square Box Locking tab prevents unauthorized detector removal Product includes 5-year warranty 6" mounting base comes with trim plate cover 900 0328-0539 Application The Potter PAD300-6DB and PAD300-4DB detector bases are used to install PAD300 series detectors. The PAD300-6DB will mount on a single gang, double gang, octagon, 4" square, 50mm, 60mm, and 70mm electrical box. Description The PAD300-6DB and PAD300-4DB are low-profile, surface-mount bases used with Potter's addressable detectors. The base uses screw clamp terminals that accept wire ranging from 22 to 12 AWG. When installed on recessed electrical boxes, the PAD300-6DB is wide enough to completely cover the back box and the immediate surrounding area. The base is equipped with a locking tab to deter unauthorized removal of the attached detector. Technical Specifications Installation Temp Range 32°F to 150°F (0°C to 66°C) Operating Humidity Range 0% to 93% (Non-condensing) PAD300-4DB: 3.93 in/ 100 mm Dimension PAD300-6DB: 6.3 in / 160 mm PAD300-4DB: 1.34 oz/ 38 g Weight PAD300-6DB: 3.03 oz /86 g Height 0.76 in / 20 mm Acceptable Wire Gauge 22 to I2AWG Single Gang Double Gang 3-1/2" Octagon Box 4" Octagon Box Mounting Options 4" Square with Plaster Ring 50mm c/c Box 60mm c/c Box 70mm c/c Box Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PRINTED IN USA 8830203- REV B • 2/23 PAGE I OF 2 (E)POTTER 3oo4DBf6D!) The Symbol of Protection 4'/6" Detector Base Locking Feature The PAD300-6DB and PAD300-4DB include a locking feature that prevents removal of the detector without using a tool. To enable this feature, break off the locking tab (See Figure 1), and then install the detector. Fig. I To remove the detector from the base when the locking feature has been enabled, insert a small screwdriver into the slot on the base to push the plastic tab while simultaneously turning the detector head counter-clockwise. Fig. 2 Wiring Diagrams Fig. 3 Class B Wiring: Class A Wiring: Class X Wiring: Insert small screwdriver into slot to remove detector from base. Ordering Information Model Description Stock No. PAD300-413B 4" Detector Base 3992781 (PAD300-613B) 6" Detector Base 3992782 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PRINTED IN USA 8830203- REV B . 2/23 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ,LISTING No.: 700-0328:0539) CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpottersignal.com DESIGN: 1Models PAD300-4DB and D3006DDetector Base. Models PAD300-4DB-I and PAD300-6DB-1 Isolator Detector Base. All models employ the same basic construction, and differ only by terminals for circuit isolation. Model PAD300-4DB is a 4 in. (10.2 cm) base with 2 terminal contacts. Model PAD300-6DB is a 6 in. (15.2 cm) base with 2 terminal contacts. Model PAD300-4DB-I is a 4 in. (10.2 cm) base with 3 terminal contacts used for isolation purposes. Model PAD300-6DB-I is a 6 in. (15.2 cm) base with 3 terminal contacts used for isolation purposes. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: Electrical ratings can vary depending on compatible detector models used. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE APPROVAL: Listed as bases for use with listee's separately listed detector heads. Refer to listee's Installation Instruction Manual for details. Models complies with the applicable requirements in UL 268, 7th Edition, UL 521, 7th Edition, and UL 2075, 2nd Edition. Compatible Detectors: Models PAD300-CD and PAD300-CD-1 (CSFM Listing No. 5278-0328:0537) Models PAD300-HD and PAD300-HD-1 (CSFM Listing No. 7270-0328:0538) Model PAD300-DD (CSFM Listing No. 3242-0328:0540) Models PAD300-PD, PAD300-PD-I, PAD300-PHD, and PAD300-PHD-I (CSFM Listing No. 7272-0328:0541) Models PAD300-PCD, PAD300-PCD-I, PAD300-PHD, and PAD300-PHD-1 (CSFM Listing No. 7275-0328:0542) 1-27-23 VWW This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational cfr requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2of2 (E)POTTER (PAD1 OO)PSSA(PSDA) Addressable Pull Station The Symbol of Protection Single/Dual Action Features Single or Dual Action versions Durable die-cast construction Reset key matches the fire alarm control panels Compatible with IPA Series panels SLC Class A, Class X & Class B Product includes a 5 year warranty LISTED Description The PADIOO-PSSA (Single Action) is activated by simply pulling the white "T" bar handle down. The PAD100-PSDA (Dual Action) is activated by lifting the front cover and then pulling the white "T" bar handle down. Once activated, the "T" bar cannot be reset without opening the front cover. Opening the front cover will also activate the pull station. To reset the PADIOO-PS Series, use the Potter WS-93 key to unlock and open the front cover. Once the cover is open, push the "T" bar back into the normal position and re-secure the front cover. Application The PAD100-PSSAIPSDA is compatible with Potter's IPA series addressable fire alarm control panels. It is a non-coded addressable pull station available in either a single or dual action model and installs on a single gang box or surface mounts using the P32-BB or P32-DBB (deep) back box. Technical Specifications Operating Voltage 24.0 VDC Max SLC Standby Current 200uA Max SLC Alarm Current 200uA 32°F - 120°F (0° - 49°C) Environmental Limitations Indoor Only Dimensions 4.75" H x 3.25" W x 1.75" D Relative Humidity Range 0 - 93% (non-condensing) Mounting Options Single gang box or Potter P32-BB/DBB Shipping Weight APS-SA - 1.22 lbs. APS-DA - 1.46 lbs. Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 • www.pottersignal.com 8830097- REV A 03/16 PAGE I OF 2 (E)POTTER (~PA~Dl OOPSSA!PSDA) Addressable Pull Station The Symbol of Protection Single/Dual Action Setting the Address The PAD100-PS Series uses one SLC address assigned to the device. The address is set using the DIP switch located on the back of the PAD 100-PS device. Pull Station Front View Fig I !I.Pwp1i JQld' L Po PAD 100-PSDA PAD100-PSSA Pull Station Back View and Wiring Fig 2 FROM FACP OR PREVIOUS DEVICE TO NEXT DEVICE FACTORY WIRED CONTACTS Ordering Information Model Description I Stock No. PAD 100-PSSA Addressable Pull Station, Single Action 3992721 ETh0-PS) Addressable Pull Station, Dual Action 13992720 Potter Electric Signal Company, LLC St. Louis, MO . Phone: 800-325-3936 www.pottersignal.com 8830097- REV A • 03/16 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7150-0328:0201 CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Lakomiak, Neil 3148168679 Email: neillpottersignal.com DESIGN: Models APS-SA, *pADloo..PSSA single action and APS-DA, PAD100PS_2 dual action addressable pull boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 22-24 VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed addressable pull boxes for use with separately listed and compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTES: These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. *Revision 02-10- 2017 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test ' results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Damon Lam, Program Coordinator Fire Engineering & Investigations Division Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Page 2 of 2 (E)POTTER PAD100-SIM) The Symbol of Protection SiilëTTnputTWIö?iiile Features One (1) Class B monitoring input SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG Product includes a 5 year warranty NOTE: This addressable module does not support 2-wire smoke detectors. Description The PADIOO-SIM uses one (1) SLC loop addresses when monitoring one (I) Class B circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring one (1) Class B circuit. The PAD 100-SIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The PADIOO-SIM is compatible with Potter's IPA series addressable fire alarm control panels. The PADIOO-SIM is an interface module used to monitor dry contact devices such as sprinkler waterfiow, valve tamper switches, or conventional pull stations. The module is capable of monitoring one Class B circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 100-SIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. J $— to IJ -J pnO°. - - - LISTED Technical Specifications Operating Voltage 24.OV Max SLC Standby 240p.A Current Max SLC Alarm Current 240pA Max Wiring Resistance 100 Q of IDC Max Wiring 11jF Capacitance of IDC EOL Resistor 5iKn Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106rnm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 • www.pottersignal.com 8830083- REVA • 03/16 PAGE I OF 2 ®POTTER CSag-lu-, AD1OO-SI The Symbol of Protection n Installation Using Compatible Electrical Box Fig I Wiring Diagram PADIOO-S!M With Class B Circuit Fig 2 JKU %w I -NE Ordering Information [odel Description I Stock No. I(PADIOO-SIM) Single Input Module 13992704 Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830083- REV A • 03/16 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0328:0500 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpottersignal.com DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, wateruiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SjMSingle Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch :PAD 100-SLCE127 Point SLC Expander MC-1 000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *SLCE..127 Loop Expander Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an '; endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06/30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 (E)POTTER The Symbol of Protection LD1OO-DIM DikilinpufMo?iiile Features Single module with dual contact monitoring inputs . Two (2) Class B or one (1) Class A monitoring inputs SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box 10) All wiring terminals accept 22 to 12 AWG ®POTFElt Product includes a 5 year warranty UUKL Listed for Smoke Control NOTE: This addressable module does not support 2-wire smoke detectors. APPROVED Description The PAD 100-DIM uses one (1) SLC loop address when monitoring two (2) Class B circuits or one (1) Class A circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring two (2) separate class B circuits making it ideal for monitoring sprinkler waterfiow and valve tamper switches when they are located in the same proximity. The PADIOO-DIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When an input is activated, the LED will flash at a fast rate. Application The PAD100-DIM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD 100-DIM is an interface module used to monitor dry contact devices such as sprinkler waterfiow, valve tamper switches, or conventional pull stations. The module is capable of monitoring two separate Class B or one Class A circuits. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 00-DIM. When the PADIOO- DIM is used to monitor two individual Class B circuits a single device address is assigned, each input is then identified as a sub-point of the module address. For example, if the address number is assigned as "8", the first input will be "8.1" and the second input will be "8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24.OV Max SLC Standby 240A Current Max SLC Alarm 240A Current Max Wiring Resistance loon of IDC Max Wiring I jiF Capacitance of IDC EOL Resistor 5.1K Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082- REV D • 12/18 PAGE 1 OF 2 PADJOO-DIM With Two Class B Circuits Fig 3 END-OF-LINE RESISTOR 5.1K OHM Part #3005013 END-OF-LINE RESISTOR 5.1K OHM Part #3005013 MOVE THE CL-A DIP SWITCH TO DOWN POSITION FOR CLASS B WIRING ®POTTER PAD1 00-DIM The Symbol of Protection 'DiiFInpufMOdiile Installation Using Compatible Electrical Box Fig I _ 1p~ NINO 10 Wiring Diagrams PADJOO-DIM With One Class A Circuit Fig 2 0 FROM FACP OR PREVIOUS MODULE 1ppltpe.' Ev RC TO NEXT MODULE Or FNOT ENDF-LINE RESISTOR R REQUIRED MOVE THE CL-A' DIP SWITCH TO"UP" POSItION FOR CLASS A WIRING Ordering Information Model Description Stock No. 1 3992703 PAD 100-DIM) I Dual Input Module Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082-REVD • 12/18 PAGE 2 OF 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: CATEGORY: 17165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 Email: timdpoftersiqnaI.com DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module !PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE 127 Point SLC Expander MC-1000 Multi-Connect 'PAD 100-DUCTR AE-2 Enclosure *sLCE127 Loop Expander Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: 1 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational c requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06130/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 (E)POTTER The Symbol of Protection Features Monitored output module that provides an additional supervised output Can be used as either a NAC or Releasing Output NAC can be wired Class A or Class B Monitors presence of 24 VDC Aux Power SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG Product includes a 5 year warranty UUKL Listed for Smoke Control Description The PAD 100-NAC module uses one (I) address on an SLC Loop. The module provides a programmable source of power to supervise and control one (I) Class B or Class A Notification Appliance or one (I) Class B Releasing Circuit. The module requires and supervises a 24 VDC auxiliary power connection. The PAD 100-NAC includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PADIOO-NAC is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PADIOO-NAC is a monitored Notification Appliance Circuit that wires to the SLC loop to provide an additional notification circuit. When used with a Potter addressable releasing panel, the PAD 100-NAC can provide an additional releasing circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switches on the PAD 100-NAC module. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. (AD1 00-NAC) NotijicatiöWAliance Cff111t ______-_-_----------- c,M9 NE r1 I OPOTIER 5U1lo I <~> 1~ APPROVED 0 Technical Specifications Operating Voltage 24.OV Max SLC Standby Current 200 jiA Max SLC Alarm Current 2000 Aux Power Required 16-33 VDC Output Ratings 24 VDC, 2A EOL Resistor 5.1K 1 EOL Resistor Diode Stock #3005012 Releasing Applications (Not Included) Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per Loop 127 units Dimensions 4.17" (I06mm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Field wiring is correctly installed. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830086-REVD • 12/18 PAGE I OF 2 Wiring Diagrams Output Connected to a Notification Appliance Circuit Typical Class B Wiring Diagram Fig 2 FROM FACP OR PREVIOUS MODULE PADSOO-NAC CLASS B END-OF-ONE RESISTOR S.SKOAM :w ParR #3005013 NOT SUITABLE FOR SYNCHRONIZATION OF NOTIFICATION APPLIANCES TO NEXT MODULE AUXILIARY 24 VOLT POWER FROM FACP (E)POTTER The Symbol of Protection NPI OO-NAC Notfi cation T45llance CiF5iiit Installation Using Compatible Electrical Box Fig I Typical Class A Wiring Diagram Fig kc o PRSSUDJS MODULE ORPREVOUSMODULE 24 VOLT POWER TO FACP OR NE El MODU LE PADSOO-NUCCLA.SSA NOTE :END-OF-LINE RESISTOR IS NOT REQUIRED NOT SUITABLE FOR RYNCHRONIZATON OF NOTFICATON APPLIANCES Releasing Application Fig 4 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE AUXILIARY 24 VOLT POWER FROM FACP 0 PAD100-NAC ROIRASjflX SoLEnoid NOTE END-OP-LINE DIODE ASSEMBLY REQUIRED P- #305012 NOTE EOL DEVICE SHALL BE INSTALLED IN THE SAME ELCTRICAL ENCLOSURE AS THE RELEASING DEVICE. It is possible that the internal relay in the PAD IOO-NAC may be shipped in the non-normal / activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description Stock No. (PAD 100-NAC) I Notification Appliance Circuit 3992707 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830086-REVD • 12/18 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: (715-0328:0500) CATEGORY: 7165- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Decker, Tim (314) 595-6748 !Email: timdpottersignal.com DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module IPADJO0- NAC)Notification Appliance Circuit Module IPAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE 127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *sLCE..127 Loop Expander Page 1 of 2 J CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: I 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, rating and UL label. AL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTES: 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational C4' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/09/2023 Listing Expires: 06(30/2024 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 f SYSTEM $ SENSOR (Outdoor SelectabIe Output Horns, Strobes, and L orn_Strobes)for (all)Applications SpectrA IWO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features (Y—Veatherproo pe EfA V, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from -40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGNAUNG . AM` 0 IVIEA 7300-1653,187 (outdoor strobes) LISTED S4011 (chimes, horn strobes, horns) APPROVED approved 7125-1653:188 (horn strobes. chime strobes) 03593 (outdoor and alert strobes) 3023572 MEA452.05-E 7135.1653189 (horns, chimes) SPECTRQUert SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40°F to 151°F Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 34-inch top and bottom conduit entries and 3,4-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. AVDS1t5.02 • 12)3)2019 • Page 1 SpectrAlert Advance Outdoor Horn, Strobe, and Horn StrobeSpecifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110,115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option 10 switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MLD3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6L x 4.7'W x 2.5D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6L x 4.7"W x 1.3'D(142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1W x 2.0' 0 (145 mm L x 130 mm W x 51 mm 0) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS1 15.02 • 12/3/2019 • Page 2 UL Current Draw Data uJ. Max. ; ri ii.miiip.mwiiiiyi ;I'ii1 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 IUL Max. Current DrawImYI 1MS), 2-Wire Horn Strobe,Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15175 30 75 95 110 115 Temporal High 137 147 79 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output (dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. .; . . Volts Volts Reverberant Anhni Strobe Output (cd) Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 Position on Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low s 75 81 81 88 84 96 92 it Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe SpectrAlert Advance Diagrams 119mm 1 Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Plastic SpectrAlert Advance Ordering Information Weatherproof Back Box Red White Wall Horn Strobes P2WK 2-Wire Horn Strobe, Standard cd. Outdoor (includes plastic weatherproof back box) P21RK-P P2WK-P 2-Wire Horn Strobe, Standard cd, Outdoor, Plain (includes plastic weatherproof back box) P2RK-R P2WK-R 2-Wire Horn Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) P21RHK P2WHK 2-Wire Horn Strobe, High cd, Outdoor (includes plastic weatherproof back box) P2RHK-P P2WHK-P 2-Wire Horn Strobe, High cd, Outdoor, Plain (includes plastic weatherproof back box) P2RHK-R P2WHK-R 2-Wire Horn Strobe, High cd, Outdoor (does not include plastic weatherproof back box) P4RK P4WK 4-Wire Horn Strobe, Standard cd, Outdoor (includes plastic weatherproof back box) P4RK-R - 4-Wire Horn Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) P2RHK-120 - 2-Wire Horn Strobe, High cd, Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK SWK Strobe, Standard cd, Outdoor (includes plastic weatherproof back box) SRK-P SWK-P Strobe, Standard cd, Outdoor, Plain (includes plastic weatherproof back box) SRK-R SWK-R Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) SRHK SWHK Strobe, High cd, Outdoor (includes plastic weatherproof back box) SRHK-P SWHK-P Strobe, High cd, Outdoor, Plain (includes plastic weatherproof back box) SRHK-R SWHK-R Strobe, High cd, Outdoor (does not include plastic weatherproof back box) Horns HRK - Horn, Red, Outdoor (includes plastic weatherproof back box) HRK-R - Horn, Red, Outdoor (does not include plastic weatherproof back box) Accessories SA-WBB SA-WBBW Metal Weatherproof Back Box WTP WTPW Metal Weatherproof Outdoor Flush-mounting Plate Notes: All-P models have a plain housing (no "FIRE' marking on cover). All -R models require metal weatherproof outdoor flush mounting plate or a metal weatherproof outdoor back box (order separately). "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. T's r57I/j 3825 Ohio Avenue 'St. Charles, IL 60174 ©2O19 System 5essor aSII.cOR Phone: 800-SENSOR2 • Fax: 630-377-6495 Product roec,tcohcrs suciect to change arthout notice. Von syote"se'oorcerrr for current product information, including the latest version at his data sheet. www.systemsensor.com AVD5115-02 • 12)312019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: i11653T0T88) CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: Iisa.branthoneyweII.com DESIGN: Models CHSR and CHSW Chime/Strobes. ModelseDR P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix K"Jndicati)indoor orfoutdoor use) or may be followed by suffix "P' for plain housing with no lettering.("K" suffix models are suitable for outdoor applicationsat temperatures from -40F to +151 *F (- 40C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listees data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. JAPPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for Iprivate mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to Ilistee's Installation Instruction Manual for details. :NOTES: Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE *Corrected 12-15- 11 bh This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/21/2023 Listing Expires: 06/30/2024 Authorized By: Damon Lam, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 UL CERTIFICATE OF COMPLIANCE for Central Station U Applicant ID No: 892912-001 L Service Center No: I Expires: 31-MAR-2024 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Comanv indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: HUNTINGTON BEACH, CA (HUNTINGTON BEACH) Alarm Service Company: (892912-001) Service Center: (892912-001) GENERAL MONITORING SERVICES INC GENERAL MONITORING SERVICES INC 17951 LYONS CIR 17951 LYONS CIR HUNTINGTON BEACH CA 92647-7167 HUNTINGTON BEACH CA 92647-7167 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category /!S6rvices) S78941 UUF Signal and Fire Alarm Equipmeit and Services] (Protective Signaling Central Station j - / **\*THIS CERTIFICATE EXPIRES ON 31MAR2024*** "LOOK FOR THE UL ALARM SYSTEM -CERTIFICATE"