HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FPC2021-0191; Permit(it of Callsbyad Print Date: 11/18/2024 Permit No: FPC2021-0191 Job Address: 5781 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2121304400 Track #: Valuation: $1,248,793.50 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Fixed Extinguishing Syste Applied: 10/07/2021 Issued: 06/21/2023 Finaled Close Out: 11/18/2024 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: Description: THERMO FISHER GOLDRUSH - PREACTION CONTROL PANEL FOR SPRINKLER PREACTION SYSTEM Applicant: FPContractor: NOVA SECURITY NOVA SECURITY CORY HILL 1950 CORDELL CT, # 107 1950 CORDELL CT, # STE 107 EL CAJON, CA 92020-0927 EL CAJON, CA 92020-0923 (619) 448-3007 (619) 448-3007 FEE AMOUNT FIRE Pre-Action System with Alarm $607.00 Total Fees: $607.00 Total Payments To Date: $607.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Gold Rush 5781 Van Allen Way Carlsbad, CA 92008 Fire Alarm Submittal 10/6/2021 Submitted By: KAI SECURITY 8779 Cottonwood Ave, Ste. 103 Santee, CA 92071 619 448-3007 Lic# CIO 802053 Cc'/ (-((LL: C1\ Gold Rush 5781 Van Allen Way Carlsbad, CA 92008 Fire Alarm Submittal Equipment List Description Model Manufacture CSFM# Fire Alarm Control Unit PFC-44 1ORC Potter 7165-0328:0170 Smoke Detector 2W-B/2WT-B System Sensor 7272-1653:0152 POTTER PFC-441ORC The Symbol of Protection RELEASING CONTROL PANEL Dimensions: 18 1/4" x 14 1/2" x 4 V UL and ULC Listed, FM Approved, NYMEA Accepted, CSFM Approved, CE Marked, and RoHS Compliant. General Description The Potter Model PFC-4410RC isaflexible multi-hazard releasing control panel that is well suited for a number of applications. The PFC-4410RC is listed for use with pre-action and deluge sprinkler suppression systems and agent based fire suppression systems. The panel utilizes a microprocessor-based system that has 24 Standard Programs, which covers a majority of installations. The simple to follow Menu Structure programs the entire system in a matter of minutes. In addition to the Standard Program s, the panel allows custom programming to accommodate any installation. Multi-Hazard Operation Four Class B Initiating Circuits Two Class B Supervisory Circuits * * Four Class B Output Circuits Programmable Cross Zoning Supervised Microprocessor 32 Character Alpha-Numeric LCD Display Custom Banner Message and Zone Description text Custom Zone Description Text On Board Menu Driven Programming Controls Releasing Circuits Protected From False Activation * Continuous or Timed Discharge 40 Event History Buffer Walktest with Automatic Time-out Alarm, Trouble Supervisory, and Waterfiow relays Optional Class A Initiating Zone and output module 34 character LED supplemental display 24 Standard Programs in Panel Memory Password Protection for all Programming 24 Hour Clock Suitable for agent or water-based extinguishing Programmable pre-discharge timers* One Class B Abort circuit* (Defaults to additional supervisory zone in water based mode.) Four Abort modest * Available in Chemical mode only ** One zone programmable as abort in chemical mode. The panel is Ninth Edition UL listed, IJLC listed, Factory Mutual, California State Fire Marshal (CSFM), New York Materials Equipment Acceptance (MEA) Approved, CE Marked, and RoHS Compliant. The PFC-4410RC is housed in a durable steel cabinet with removable door and key lock. The panel is available in either a red or white finish and an optional flush mount trim ring is available. The cabinet contains knockouts on the side, back and top of the cabinet to ease installation. In addition, the cabinet will house up to 18 amp-hour batteries that will provide in excess of 90 hours of standby power. Ordering Information Model Number Description Stock Number PFC-4410RC 4 Zone Releasing Control (White Cabinet) 3006144 PFC-4410RC 4 Zone Releasing Control (Red Cabinet) 3006142 PFC-4410RC-PCA Replacement Motherboard 3006230 PFC-TW Bezel for Semi-Flush Mounting (White) 5090157 PFC-TR Bezel for Semi-Flush Mounting (Red) 5090155 BT-80 Battery, 12V 8AH for 24 hour standby (2 Req'd) 5130084 BT-120 Battery, 12V 12AH for 24 hour standby (2 Req'd) 5130090 BT-180 Battery, 12V, 18AH for 90 hour standby (2 Req'd) 5130086 CA2Z 2 Zone Class A Initiating Circuit Module 3006013 CAM Class A Indicating Circuit Module 3005300 ARM-44 Relay Module for PFC-4410RC 3006221 ARM-2 Auxiliary Relay Module 3004725 RA-4410RC Remote Annunciator 3006400 BB-RA-44R Surface Mount Back Box for RA-4410RC (Red) 3006401 Potter Electric Signal Co., LLC • St. Louis, MO - Cast Service; 866-240-1870 • Tech Support:866-956-1211• Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG #5401250 - REV C PAGE 1 OF 2 3/14 (DPOTTER The Symbol of Protection Architects/Engineers Specifications The control panel for the extinguishing agent releasing system shall be a microprocessor based control capable of protecting multiple hazards in one control panel. It shall be Underwriters Laboratories Inc. listed under Standard 864 Ninth Edition and Underwriters Laboratories of Canada for Local Control Units for Releasing Service. The control shall also be approved by Factory Mutual Research Corporation and be compliant with the requirements of NFPA-72 (Local: A, M, SS service types; DAC and NC signaling type) and NFPA12, NFPAI2A, NFPA-13, NFPA-15, NFPA-16, NFPA-17, NFPA-17A, NFPA-750, and NFPA-2001. The control shall be housed in an 18 gauge steel cabinet that has a hinged, removable door with a key lock. The finish shall be baked enamel and available in red or off-white with contrasting trim and logo. An optional matching bezel should be available for semi-flush mounting. The cabinet shall have adequate space to house 18 AH standby batteries capable of operating the system for at least 90 hours. The control shall include a fully supervised integral power supply/battery charger capable of providing 200mA to the auxiliary power circuit. It shall also be capable of providing 2.5 Amps to all releasing and notification appliance circuits combined. All initiating, output and auxiliary power circuits shall be power limited. The control shall have a 32 character (16 characters, 2 lines) backlit LCD display and a 34 LED supplemental display. All diagnostic and alarm event information shall be viewable in text form on this display. A field programmable custom banner message with the current date and time shall be displayed when no current alarm or diagnostic information exists. All operational features of the control panel shall be field programmable using menu driven selections on the alpha-numeric display and on board controls. No special programmer will be required and jumpers or switches to configure operational features shall not be permitted. Alarm and trouble indications shall resound when required. The control panel shall be equipped with 24 programs built into the panel memory, 15 for water based extinguishing and 9 for agent extinguishing. In addition, the panel shall have the ability to add custom programs. All programming functions shall be password protected. The control shall have four fully supervised Class B (Style B) initiating circuits capable of supporting the operation of 25 compatible 2-wire smoke detectors on each circuit. The individual circuits shall be selectable through the programming sequence to operate in one of the following modes: Conventional, PFC-44 1ORC RELEASING CONTROL PANEL Waterfiow, Linear Heat Detection (up to 700 ohms per zone), Manual Release, Low Air Alarm, Supervisory, Tamper, Low Air or High Air. Optional Class A modules, CA2Z, may be added for Class A operation. The panel shall have a Low Air Zone that creates a supervisory condition and can be mapped to a release output. The control shall have two fully supervised Class B (Style B) supervisory circuits. These circuits shall be selectable through the programming sequence to operate in one of the following modes: Supervisory, Tamper, Low Air or High Air. The control shall have one fully supervised class B (style B) Abort circuit with 4 different operating modes, ULI, IRI, and NYC, and 30 second. The control shall have four fully supervised Class B (Style Y) output circuits. These circuits shall be selectable through the programming sequence to operate as one of the following: Alarm Notification Appliance, Supervisory Notification Appliance, Trouble Notification Appliance or Releasing. The optional CAM module may be added to convert the outputs to Class A. The panel shall have an RS-485 output and auxiliary power outputs for connection and supervision of up to 4 remote annunciators or an ARM-44 Relay Module and 3 annunciators. The releasing circuits shall be supervised for short circuit conditions and shall be programmable for cross zoning operation when required. The discharge timer for these releasing circuits shall be programmable for times of 7, 8, 9, 10, 20 minutes or continuous. All initiating and output circuits shall be capable of being individually disabled or enabled. In addition, when in the agent extinguishing mode there shall be a pre-discharge timer adjustable from 0-60 seconds from an alarm zone or 0-30 seconds from a manual release zone. The control shall have a test mode that will automatically disable all releasing circuits. The test mode shall operate in such a manner as to automatically reset the initiating circuit and indicating circuits after detecting each alarm condition initiated by the test. All testing shall be recorded in the 40 event history buffer. The test mode will automatically terminate after twenty minutes of inactivity. The control shall have four integral relay contacts rated 3 Amps at 30 VDC for connection to external auxiliary equipment. One relay shall operate when an alarm condition occurs, another when a trouble signal occurs, the third when a supervisory condition occurs, and the fourth during a waterfiow condition. UL and ULC Listed, FM Approved, NYMEAAccepted, CSFM Approved, CE Marked and RoHS Compliant PRINTED IN USA MFG #5401250 - REV C PAGE 2 OF 2 3/14 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7165-0328:0170. Page 1 of 1 CATEGORY: :7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Brad Serangeli (314) 595-6900 Fax (314) 595-6999 Email: bradspottersignal.com DESIGN: Model PFC-4410RC and PFC-4410ARCfire alarm control units Automatic, manual, noncoded, local, remote station, central station, releasing device, waterfiow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. Minimum system components: (PFc-4410RC" Control Unit PFC-44I0ARC Control Unit with LED annunciator Suitable for use with the following modules: RA-4410RC, CA2Z, CAM, ARM-I, ARM-2, *ARM44 and SG-32. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Suitable for high-rise applications when used with separately listed voice evacuation systems. Refer to listee's Installation Instruction Manual for details. These control units do not generate a Temporal Pattern Signal. If the distinctive three-pulse Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Model PFC-4410RC control unit meets the requirements of UL Standard 864, 9th edition. Model PFC-44I0ARC control unit meets the requirements of UL Standard 864, 8th edition. NOTE: Combined with 7170-0328:171 *Rev 06-18-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 'Listing Expires June 30, 2022', Authorized By: DAVID CASTILL.O,, M.E., F.P.E. Fire Engineering Division PFC-4410RC • 5403550 • REV Q' 11/12 2-Wire Smoke Detector Compatibility Data Smoke Detector Compatibility Identifier "A" Det. Model Identifier Base Model Identifier 1400* A N/A N/A 2400 A N/A N/A 2400TH* A N/A N/A 2W-B A N/A N/A 12WT-0 A N/A N/A 2WTR-B A N/A N/A Detection Systems (Max. No. Of Detectors Per Zone Is 25) Det. Model Identifier Base Model Identifier DS250 A MB2W/MB2WL A DS250TH A MB2W/MB2WL A DS250HD A MB2W/MB2WL A Esi (Max. No. Of Detectors Per Zone Is 25) Det. Model Identifier Base Model Identifier 611U S1O 6011J SOO 61IUD S10 601U SOO 611UT 510 601U SOO 612U S10 601U SOO 612UD slo 601U SOO 613U5 SIO 601U SOO 6IIUD slo 609U10 SOO 612UD Slo 609U10 SOO 425C Sb N/A N/A 425CT Sb N/A N/A Hochiki (Max. No. Of Detectors Per Zone Is 25) Det. Model Identifier Base Model Identifier SLR24* HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 NS6-220 HB-3 SLR24H* HD-3 HSC-221R BB-71 HSB-221 BB-54 HSB-221N HB-54 NS6-221 NS4-221 SIJ24* HD-3 HSC-221R HB-71 HSB-221 BB-54 HSB-221N HB-54 NS6-221 NS4-221 Fenwal (Max. No. Of Detectors Per Zone Is 25) Det. Model Identifier Base Model Identifier CPD.7051* I51EE1 2-WIRE FE51A PSD7155* P55FE1 2WRLT FE52A PSD7156* P56FE1 2WRB FE55A All of the above Fenwal detectors and bases can be used in any combination Retrofit Base Adaptor 70-501000-003, Identifier MAFE1 (for series 70-201000 Bases, Models -001, -002, -003 and -005) Duct Housing with Detector Base DH-51, Identifier DH22FE5 (for CPD-7051 and PSD-7155 detectors only) Potter (Max. No. Of Detectors Per Zone Is 251 Det. Model Identifier Base Model Identifier PS24* HD-3(HOCHIKI) SB-46 HB-71(HOCHIKI) HB-54(HOCHTKI) SB-93 HB-3 (HOCHIIKI PS-24H HD-3(HOCHLKI) SB-46 HB-71(HOCHIIU) MB-54(HOCHlKI) IS24* HD-3(HOCIIIKI) SB-46 HB-71(HOCHTKJ) HB-54(HOCHIKI) S Only one detector can be supported in alarm per zone. If using a mix of System Sensor and other smoke detectors, a maximum of 20 detectors shall be permitted. Sync Module Compatibility - Panel is compatible with the following synchronization modules: Amseco #SMDb0-3A, Gentex #AVSM, System Sensor #MDL, Wheelock #DSM12/24 *UL and ULC Listed 89 Photoelectric Smoke Detectors System Sensor j3" series smoke detectors represent significant advancement in conventional detection. The j3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings ® LISTED ' MEA MSFM APPRMD approved approved 41US 5911 3011446 7272-1653:152 290-01-8 2093 3180932 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize nuisance alarms. 2-wire P detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i protocol. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent-per-foot obscuration. Instant Inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire 13 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (j. Smoke Detector Smoke detector shall be a System Sensor j3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57,2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pie-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage 1 Nominal: 12/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V.23 mA @24 V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings Dimensions (Including base) 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 63 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire .130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4W1-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/ maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6,6 inch (16.76 cm) diameter f - 2W9 Systenn Sensor. SYSTOW 3825 Ohio Avenue. St. Charles, IL 60174 Product specifications subject to change wishoutno5ce.visit systemsnnsor.comw Phone: 800-SENSOR2 . Fax: 630-377-6495 cueentpecdorInkoduding the Iatester0cnofthn data sheet Z45 SENSOR' A0-0318.007 .6/09. #2169 11 ~Rlkk. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION U OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Aft LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: Iisa.brant@honeywelI.com DESIGN: Models 2W-B, 2WT-B, 4W-B, and 4Wr-6 photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and models 4W-B and 4W1-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. *The above models comply with UL 268, Seventh Edition. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 *Revision 09-21-20 VWN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 30.63 VICTAULIC IS AN ISO 9151 CERTIFIED COMPANY Series 753.E FireLock® 300 psi Solenoid PRODUCT DESCRIPTION The Series 753-E FireLock solenoid is designed for use with Victaulic FireLock Preaction and Deluge devices that use electric actuation. Approved for a NEMA 4 classification the Series 753-E is rated to 300 psi/2065 kPa and is UL/ULC Listed and FM Approved for indoor or outdoor use. The solid brass construction provides protection against falling dirt, inclement weather, windblown dust, splashing and hose-directed water. The solenoid uses a 1/2 /21,3 mm NPT connection and is wired for 24 VDC service. See Victaulic Publication 10.01 for details. DIMENSIONS Dimensions Aprx. Size Weight Each Inches/mm A B C D LbsJkg 1/2 3.75 2.75 1.50 2.96 1.2 21.3 95 70 38 75 0.5 MATERIAL SPECIFICATIONS Body: Forged Brass Spring: 300 Series Stainless Steel Seal: Fluoroelastomer Diaphram: Fluoroelastomer Wiring: 24 VDC Voltage: 24 VDC Power Rating: 8.7 Watts Resistance: 66 Ohms Current: .364 Amps This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. S REGISTERED TRADEMARK OFVICTAIJLIC - S COPYRIGHT2005VICTAULIC - PRINTED INU.S.A.-SKU#WCAS-6H9N79 3I64 REV C United States • Phone: 1-800-PICK-VlC (1-800-742-5842) • Fax: 610-250-8817 • e-mail: pickvic@victaulic.com Canada • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada@victaulic.com Europe . Phone: 32-9-381-1500 • Fat: 32-9-380-4438 • e-mail: viceuro@victaulic.be c UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e-mail: viceuro@victaulic.be S Central and South America • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vical@victaulic.com tauIi Australasia • Phone: 86-21-54253300 Ext 202 • Fax: 86-21-54253671 • e-mail: vicap@victaulic.com j# (E)POTTER PFC-441ORC The Symbol of Protection COMPATIBLE RELEASING DEVICE LIST Releasing Panel for Water and Agent Extinguishing Systems (All specifications subject to revision.) Automatic Water Control Valves _Compatibility _Data Using the Following Solenoids Devices Per Circuit Water Valve Manufacturers Water Valve Designation Size NPT ASCO Solenoid Valve 1 Figgie Fire Protection Model D and F 21/2 ', 4", 6" Model 18210A107 Systems (Formally ASCOA) Model R8210A107 Model 8210A107 24VDC Parker/Skinner Grinnell Corp. Grinnell or Gem Model A-4 4", 6" Solenoid Valve Model Grinnell or Gem Model B 2" 732l8BN4UNLVN0C1l12 Grinnell or Gem Model F445 2W' 24VDC Grinnell or Gem Model F470 4", 6" Parker/Skinner Solenoid Valve 1 Central Sprinkler Model A 6" Model Reliable Automatic Sprinkler Model A 2W' 73218BN4UNLVN0C1112 Co. Inc. Models B, BX and DDX 4", 6" 24VDC 100mm, 150mm Global Fire Sprinkler Corp. Model F 2Y2",4", 6" Star Sprinkler Corp. Model A 3", 6" Model G 3", 6" ASCO Solenoid Valve 1 The Viking Corp. Model E-1 PA", 2", 3", 4", 6" Model T8210A107 Model R8210A107 Model 8210A107 24VDC Sirai Solenoid Valve 1 Minimax FSX-A DN50, DN80, L182/ZB12A DN100, DNI50, ____________ _________________ DN200 PRINTED IN USA MFG. #5403615. REV H PAGE 1 OF 2 01/19 (E)POTTER PFC-44 1ORC The Symbol of Protection COMPATIBLE RELEASING DEVICE LIST Solenoid Compatibility Data Manufacturer Devices Per Circuit Solenoid(s) Voltage Victaulic I 753-E Series, 767 Series 24VDC Viking 1 11591, 11601, 11602,13843 or 13844 24VDC Parker 1 73212BN4TNLVN0C322C2, 732I8BN4UNLVNOH111C2, or 7321GBN99NLVN0C322C2 24VDC TLX 1 PA0036 24 VDC Burkert 1 5282 24 VDC SIRAI 1 ZB12A 24VDC FM Approval Solenoid Groups A, B, D, E, F, G, I, J, K., L Cease Fire Canister Automatic Release. Maximum 8 Per Release Circuit. Agent Releasing Systems Compatibility Data Manufacturer Actuator Voltage Fike Protection Systems Division of Fike, Inc. C85-102 CO2 Solenoid 24 VDC Fike Protection Systems Division of Fike, Inc. Interface Firing Module P/N 102136* 24 VDC Fike Protection Systems Division of Fike, Inc. Direct Fired Impulse Actuator (DFIA) 2-13279 24 VDC Janus FM200 Electric Valve Actuator P/N 18481 24 VDC Amerex 17014 24VDC Fireaway Stat-X Models 30E, 60E, 100E, 250E, 500E, I000E, 1500E, and 2500E Aero-k Models G30, G60, GIOO, G250, 0500, GI000, G1500, and G2500. Maximum 10 per release circuit, two release circuits max per panel. 24 VDC Minimax MX1230 and MX200 with Minimax actuator 887667 and 889323 24 VDC Viking VSN1230 and VSN200 with actuator 16360 24 VDC Fike UVO Model 02-13571 24 VDC TLX PAO 128-7, PA0337 24 VDC Masteco MSC-01 24 VDC FirePro Model FP followed by a - number and letter suffix Maximum 10 per release circuit, two release circuits max per panel 24 Hochiki Model FNX followed by a - number and letter suffix Maximum 10 per release circuit, two release circuits max per panel 24 v DC Alarm Indicating Appliance Compatibility Data All alarm indicating appliances must be UL Listed, 24 VDC devices ***REFER TO 5403550 PFC-4410RC MANUAL FOR MORE INFORMATION"* PRINTED IN USA MFG. #5403615 - REV H PAGE 2 OF 2 01/19