880 CARLSBAD VILLAGE DR; ; AS130120; Permit
9/14/22, 2:16 PM AS 130120 Permit Data City of Carlsbad Sprinkler Permit 880 CARLSBAD Job Address: VILLAGE DR Permit Type: SPRINK Parcel No: 2033541600 Lot #: 0 Reference No.: PC #: Permit No: AS130120 Status: APPROVED Applied 7/25/2013 Approved: 7/29/2013 Issued: 7/29/2013 Inspector: Project Title: SUPERCUTS T.I. INSTALL NEW FIRE SPRINKLERS PER NFPA 13 FOR A NEW TENANT IMPROVEMENT Applicant: INNOVATIVE FIRE PROTECTION INC STE 101 8779 COTTONWOOD AV SANTEE CA (619) 593-8200 (619)593-9133 Owner: BURECK CAPITAL L L C 1923 DENTRO DE LOMAS BONSALL CA Fees ($) Add'I Fees ($) Total ($) F Balance ($) 268 0 268 about:blank 1/1 fSflS 1-( Jellk - 71v1/,3 0 Automatic Sprinkler Systems 1 FORM2-J Contractor's Material and Test Certificate for Aboveground Piping IDate: 7/31/13 Property Name: Seaside Village Corner L Property Address: 860 Carlsbad Village Dr. Procedure Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and the system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authori- ties, owners, and contractors. It is understood that the owner's representaj's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failurefbiply with approving authority's requirements or local ordinances. Plans Accepted by [approving authority's name(s)] Carlsbad Fire Dept. - Address Installation conforms to accepted plans? 2 Yes El No Equipment used is approved? 2 Yes El No If no, explain deviations. Instructions Has person in charge of fire equipment been instructed as to location of control valves and care and maintenance of this new equipment? 121 Yes El No If no, explain. Have copies of appropriate instructions and care and maintenance charts and NFPA 13 been left on premises? 121 Yes El No If no, explain. Location of System Supplies building(s) Building Landscape Sprinklers Year of Orifice Temperature Make Model Manufacture Size Quantity Rating Reliable RA1414 2013 5.6 14 155 Reliable RA1414 2013 5.6 30 200 Reliable RA1425 2013 5.6 171 200 Reliable RA1435 2013 5.6 11 200 Pipe and Fittings Pipe conforms to NFPA 13 standard. 21 Yes El No Fittings conform to NFPA 13 standard. 121 Yes El No If no, explain. PAGE lof3 Copyright © 2000 National Fire Protection Association Automatic Sprinkler Systems FORM 2-J Contractor's Material and Test Certificate for Aboveground Piping (cont.) Alarm Valve or Flow Indicator Alarm Device Maximum Time to Operate Through Test Pipe Type Make Model Mm. Sec. Water Flow System Sensor WD25 50 Dry Pipe Operating Test Dry Valve Q.O.D. Make Model Serial No. Make Model Serial No. Time to Trip Trip Point Time Water Alarm Through Water Air Air Reached Operated Test Pipe* Pressure Pressure Pressure Test Outlet* Properly Mm. Sec. Psi (Bar) Psi (Bar) Psi (Bar) Mm. Sec. Yes No Without Q.O.D. With Q.O.D. If no, explain. N/A Deluge and Preaction Valves Operation El Pneumatic Electric fl Hydraulic Piping supervised? Yes El No Detecting media supervised? 0 Yes II No Is there an accessible facility in each circuit for testing? El Yes El No If no explain. N/A Does each circuit operate Does each circuit Maximum Time to supervision loss alarm? operate valve release? Operate Release Yes No Yes No Make Model Mm. Sec. Test Description HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for two hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for two hours. Differential dry pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. FLUSHING: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Flush at flows not less than 400 gpm (1514 L/min) for 4-in. (102-mm) pipe, 600 gpm (2271 L/min) for 5-in. (127-mm) pipe, 750 gpm (2839 L/min) for 6-in. (152-mm) pipe, 1000 gpm (3785 L/min) for 8-in. (203-mm) pipe, 1500 gpm (5678 L/min) for 10-in. (254-mm) pipe and 2000 gpm (7570 L/min) for 12-in. (305-mm) pipe. When supply cannot produce stipulated flow rates, obtain maximum available. *Measured from time inspector's test pipe is opened. PAGE 2 of 3 Copyright © 2000 National Fire Protection Association Automatic Sprinkler Systems FORM 2-J Contractor's Material and Test %91 Certificate for Aboveground Piping (cont.) Test Description (cont.) PNEUMATIC: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1112 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1112 psi (0.1 bar) in 24 hours. Tests All piping hydrostatically tested at 200 psi (bar) for 2 hrs. Dry piping pneumatically tested? U Yes El No Equipment operates properly? U Yes U No If no, state reason. Drain test—Reading of gauge located near water supply test pipe: Static pressure: 75 psi (bar) Drain test—Residual pressure with valve in test pipe open wide: 66 psi (bar) Underground mains and lead-in connections to system risers flushed before connections made to sprinkler piping Verified by copy of the U Form No. 85B U Yes U No El Other Flushed by installer of underground sprinkler piping U Yes U No U Other If other, explain. N/A Blank Testing Gaskets Number used N/A Locations Number removed Welding Welded piping? U Yes U No If yes, Do you certify as the sprinkler contractor that welding procedures comply with the requirements of at least AWS D10.9, Level AR-3? U Yes U No Do you certify that the welding was performed by welders qualified in com- pliance with the requirements of at least AWS D10.9, Level AR-3? U Yes U No Do you certify that welding was carried out in compliance with a documented quality control procedure to insure that all discs are retrieved, that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? U Yes U No Hydraulic Data Nameplate Nameplate provided? ZI Yes U No If no, explain. Remarks Date left in service with all control valves open: 7/31/13 Sprinkler Contractor: Signatures of Test Witnesses For property owner (signed) Title Date For sprinkler contractor (signed) Title Date PAGE 3 of 3 Copyright © 2000 National Fire Protection Association Bulletin 0149ev. J Model Fl FR Series Quick Response' Standard Spray Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent/Fl/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, F1FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendant Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH 5 *f5 Certified to NSF/ANSi Standard 61 Annex 0 UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers t V. Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/Fl/F2 1. Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP' . XLH Upright XLH Pendent Pendent F1 /F2 to apply water to afire much faster than standard sprinklers of the same tem- perature rating. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass XLH Recessed bulb is specially constructed to provide Pendent F fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preac t i o n . C a r e m u s t b e exercised that the orifice size, temperature rating, deflector style and sprinkler type are in acc o r d a n c e w i t h t h e l a t e s t published standards of the National Fire Protection Association or the approving Authority Havin g J u r i s d i c t i o n . Q u i c k response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers a n d s t a n d a r d r e - sponse sprinklers should not be intermixed. *Ptnt/e (XLI-! Only) Deflector Load Screw Washer Bulb Frame Cup 0 14FGO6A Model F1FR42. F1FRXLH Unriaht Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL 1t K 5.6 Quick 1/2" NPT See See F1FR42 **F1FR42LL0) K 4.2 Response (RI/2) 175 PSI 7 PSI "Temperature "Finish Table" F1FRXLH K 2.8 Ratings" Table. F1FR28 Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape CDA Alloy510 2. Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model F1FR42, F1FRXLH & F1FR28 Upright & Pendent Sprink l e r s Installation Wrench: Model 0 Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Orifice Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Po s i t i o n 1/2 (15mm)(' 1/2" NPT(R1/2) 5.6 80 2.25' (57mm) 1,23,4 RA1425 253 7/16" (10mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) 1 RA 14230) RA1413 3/8" (10mm) 1/2" NPT(R1/2) 2.8 40 2.25' (57mm) 1 RA14211 RA1411 Conventional-Install in Upright or Pendent Position 15mm " 1/2" NFl (R1/2) 5.6 1 80 J 57mm 3, 4 RA14753 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & R A 1 4 7 5 . Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Orifice _____________ Size US I Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) °) 1/2" NPT (R1/2) 5.6 80 2.25(57mm) 1,5 RA1414 7/16" (11mm) 1/2' NPT (R1/2) 4.2 { 60 2.25" (57mm) 1,5 RA1413 cULus listed corrosion resistant (Polyester coated) sprinkler. 3. [ 0 0(6005 (0060550 WRests 6055 5 j rA of '1 tWO so once op (0(00 0,0040', n/csossj 43 AOAOUS(N - - - 000oss - S or 590srjw RICE 5' AY A- 9(0(55 (AJ Ar 5055595 RECESS - Al- RECESS AT WM 23/800.(66rWrj 0(50 0 C00550 0 SS"S 000 [59 ""3 505CC Or 455000 5 FoCI Sr 0(5550 350(5,04', S (5(5/0555 rECCES$ - '/27J0oco) 500055 - 9 ssstoss. sfCESS .' 0(55SROO 9(0955 - 'Too Ao',sj J'/6 0.9 -6 [&ei000rj Model F1FR56, F1FR42, F1FRXLK & F1FR28 Quick Response Recessed P e n d e n t S p r i n k I e r 1) Installation Wrench; Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread :K Factor Size US Metric Sprinkler Height Sprinkler Identification Number (SIN) 1/2 (15mm) 1/2' NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25' (57mm) RA1413 (10mm) 1/2" NPT(R1/2) 2.8 40 2.25(57mm) RA1411 01 Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprin k l e r 0) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread K Factor Size j US ff Metric Sprinkler Height Sprinkler Identification Number (SIN) 112" (15mm) 1/2" NPT(R½) 5.6 1 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) RA1413 1) Rater to escutcheon data table for approvals & dimensions Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28F1 or F2 Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal I i I Nominal K Factor Sprinkler Sprinkler Approval US Metric Orifice Thread Height Identification Organizations 1/2" (15mm) %" NFl (R1/2) 5.6 8.0 2.25" (57mm) 1,2,3,4 - - 15mm J' NFl (R1/2) 5.6 8.0 2.25 (57mm) RA148523 40) II) LPC Approval is for pendent position only cULus Listed corrosion resistant (Polyester coated) sprinkler. Sprinkler Type Deflector to Ceiling Distance (Min. 4" 102mm -1?" (305mm Pendent 0)psmm) Vertical Sidewall 4. Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler 1 Approval Organizations Sprinkler Nominal Orifice Thread Size _________________ Height and Type of Approval Identification I US Metric Light Hazard Ordinary Numbers (SIN) Hazard ½"(15mm), ½" NPT (R1/2) 5.6 80 2.63 (67mm) 1,2 - 1 RA14351 '2 cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. FACE OF FITThVC TO FACE OF CEILING DIMENSION At MAXIMUM RECESS I '[25. 4rfl,1IJ fr AT MINIMUM RECESS .5/874.51m) Ft ESCUTCHEON 12 ESCUIGNEON \ IZ AT MAXIMUM RECESS = F —3/6734 AT MAXIMUM RECESS = 3/4779] / AT MINIMUM RECESS = 2—I/16752.4 T AT MINIMUM RECESS = 3/8 Tg 5,] AT MAXIMUM RECESS = I_5/8'[47.3m1 2 1/4' HOLE 014. i At MINIMUM RECESS 2- I,'I6752.4m] XI/2EDUCER F511 Ls DA. 2 713 DLA CEILING r() [72.2] DEFLECTOR TURN COLLAR UNTiL TIGHT AGVNST SPR.WXLER WRENCH SOS,, J/47l9r] AO4USTMENT F2 ESCUTCHEON t/2'[12. 45,jU5ryiV7 Horizontal Sidewall RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR A" - 6' 001.600 - 752.4MM] CEIUNG 70 DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. Model F1FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread US Metric Size Model Temp. Rating Max. Ambient Temp Bulb Color - Approvals Sprinkler Identification Number(SIN) Sprinkler Cover ½" (15mm) 5.6 80 1 ½" NPT F1FR 135°F/570C 1351F/571C 100°F/38°C Orange 1 RA1414 112" (15mm 5.6 80 i ½" NPT F1FR 1551F1681C 1350F/570C 1oo°F/38°C Red 14(1) RA1414 'b" (15mm) 5.6 80 1 ½" NPT F1FR 1751F/791C I 165°F/74°C 100°F/38°C Yellow 1 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 2001F/931C 165°F/74°C 1500F/651C Green 1 RA1414 (i) For VdS only = 155°F/66°c Norbulb'and 1/2" [127mm] adjustment. Model F1FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC Sprinkler Wrench Technical Data: - Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. ' Ambient Bulb Color Approvals Sprinkler Identification I Metric T Sprinkler Cover us f j Temp Number(SIN)] ½"(15mm56 80 [J_' NPT F1FR56LL 200F/93°C I 165°F/740C 150°F/65°C Green 15L RA 1414 5. I" x 1/2 REDUCING TEE OR ELBOW 2 5/8 MA. LIt' 'R 2 U HOLE IN CEILING F FITTINC 7— DIMENSION 'OVER N JTOL0GFC COVER PLATE - ' 4550.6 I 5/16 OI, SPRINKLER ADJUSTMil Figure 1 Installation Aid A protective cap is included for use during installation. Important: The Fl FR56 Sprinkler with Model COP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model Fl FR56, F1FR56LL, Fl FR42, F1FR42LL, F1FRXLH & Fl FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LLJCCP Concealed Sprinkler use the ½" orifice, 1/2 NPT (R1/2), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model COP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (680C), 175°F (79°C) or 200°F (930C). The Model F1FR56LL Pendent is available only in a rating of 200°F (930C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model COP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the F1FR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark 6. I' 1/2 REDUCING TEE OIL 060W '. 2 5/16 014 HOLE IN CEiLING CUP 1/2 MAX. FACE or rITINIG I TO FACE OF CEILING DIMENSION rPLING COVER SEII L COVER PLATE 4 - 0EI,IBLY 3 5/16 OA SPRINKLER -" CONCEALED, 5/16" ADJUSTMENT Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2 /8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model AOl Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model Fl FR56 Pendent Sprinkler or the use of the Model COP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. Temperature Ratings Sprinkler Temperature Max AmbientClassification Temp. Bulb Color Ordinary 57 t 135 100°F(38°C) Orange Ordinary 68 155 100°F(38°C) Red Intermediate 79 175 150°F(66°C) Yellow Intermediate 93 200 150°F (66°C) Green High 141 286 225°F (107°C) Blue ) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus permits use with Fl F2 or PP escutcheons for "light hazard only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes LSprinkler Escutcheon Cover plate1 Bronze Brass Chrome Plated 1 Chrome I Chrome Polyester Plated White Coated (4)(5)(6) White Painted J Special Application Finishes Sprinkler Escutcheon plate(') Bright Brass ° Bright Brass Bright Brass Black Plated Black Plated Satin Black Paint (2)(6) 1 Black Paint Off White Off White Off White Black Paint Satin Chrome i Satin Chrome I Black Plated- 11) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cuLus Listed only. ° 200°F (93°C) maximum. cuLus listed 'corrosion resistance' applies to SIN Numbers RA1435 (HSW), RA1485(VSW), 8A1425 (Upright), RA1414 (Pendant) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as 'Polyester coated' applies to SIN Number RA1414, 8A1435 and RA1425 in standard black or white. 01 LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately 7.