HomeMy WebLinkAbout3115 MELROSE DR; ; AS070162; Permit12/27/24,10:06 AM AS070162 Permit Data City of Carlsbad Sprinkler Permit Job Address: 3115 MELROSE DR Permit Type: SPRINK Parcel No: 2218801300 Lot #: 0 Permit No: AS070162 Status: ISSUED Applied 6/14/2007 Approved: 6/14/2007 Reference No.: Issued: 6/14/2007 PC #: Inspector: Project Title: PROGRESSIVE CLAIMS OFFICE THREE FIRE SPRINKLER INSPEXTIONS @ $62/EA Applicant: ADVANCE FIRE PROTECTION 1451 W. LAMBERT RD LA HABRA, CA 714-526-2231' OWner: OPUS WEST CORP 4350 LA JOLLA VILLAGE DR #110 SAN DIEGO CA Fees Add'l Fees_($) Total ($) Balance($) 186 0 186 0 about:blank 1/1 9 TTJ t I, ~Iq I - - Fire Protection by Computer Design Advance Fire Protection Co. 1451 W. Lambert Road La Habra, CA 90631 562-691-0918 Job Name : PROGRESSIVE - CLAIMS OFFICE Building : LOT 25 Location : 3115 MELROSE DR-CARLSBAD, CA. System ST FLOOR Contract : 07-0335 Data File : 07-0335.WXF APPRQVED AS S 7111~ Te TTED __ 74u , - CAD FIRE PA 9NT Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Advance Fire Protection Co. Page 1 PROGRESSIVE - CLAIMS OFFICE Date 6-6-07 Hydraulic Design Information Sheet - Name - PROGRESSIVE - CLAIM OFFICE Date - 6-6-07 Location - 3115 MELROSE DR.-CARLSBAD, CA. Building - LOT 25 System No. - 2ST FLOOR Contractor - ADVANCE FIRE PROTECTION Contract No. - 07-0335 Calculated By - CHARLIE T. Drawing No. - 1 OF 1. Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 91 -.0 Occupancy - OFFICES S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E N Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - 0.1 (X) Wet Make TYCO D Area Per Sprinkler - 324 ( ) Dry Model EC-11 E Elevation at Highest Outlet - 9 ( ) Deluge Size i" ORIFICE S Hose Allowance - Inside - 100 GPM ( ) Preaction K-Factor 11.2 I Rack Sprinkler Allowance - N/A ( ) Other Temp.Rat.155°F G Hose Allowance - Outside - N/A N Note Calculation Flow Required - 401.57 Press Required - 56.084 At BOR Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 1-18-06 Cap. - T Time of Test - 9:18 AM Rated Cap.- 500 Elev.- E Static Press - 135 8 Press - 75 R Residual Press - 126 Elev. - 2 Well Flow - 2632 Proof Flow S Elevation - 0 U P Location - EXISTING CITY WATER MAIN IN LIONSHEAD AVE. P L Source of Information - WATER FLOW TEST WITH MARK SODERGERG-CARLSBAD FIRE INS Y Commodity Storage Ht. Storage Method: Single Row Double Row Mult. Row Class Area Solid Piled % Conven. Pallet Slave Pallet Location Aisle W. Palletized % Rack Auto. Storage ( ) Encap. Solid Shelf ( ) Non Open Shelf Flue Spacing Clearance:Storage to Ceiling Longitudinal Transverse Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C 0 N N SR TA O C R K A G E AMINA IIIIIIIIIIIIF WIN E FIRE PROTECTION CD., INCA 1451 WEST LAMBERT ROAD LA HABRA, CALIFORNIA 90831-6599 (562) 691-0918 (714) 526-2231 FAX$ (562) 691-5482 STATE LICENSE 259936 January 23, 2006 City Of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 Attn: Mark Soderberg Re: Fire hydrant flow test results performed at 3190 Lionshead Avenue, Carlsbad, CA Dear Mark, The results of the Fire Flow test performed at the above address are as follows: Static Water Pressure: 150 psi Residual Water Pressure 140 psi Observed Water Flow: 2632 gpm Pitot Reading: 75 psi Outlet Size: 2% inch x 2 outlets flowing simultaneously Flow At 20 psi: 10529 gpm (Calculated) Date: 1-18-06 Time: 9:18 am As you may know, daily usage can fluctuate and may change results. Feel free to contact me with questions or concerns regarding this test. Sincerely, Advance Fire Protecti Co., Inc. Brian Callahan VP of Engineering Water Supply Curve (C) Advance Fire Protection Co. Page 2 PROGRESSIVE - CLAIMS OFFICE Date 6-6-07 City Water Supply: Demand: Cl - Static Pressure : 135 Dl - Elevation : 5.124 C2 - Residual Pressure: 126 D2 - System Flow : 301.567 C2 - Residual Flow : 2632 D2 - System Pressure : 65.403 Hose(Adj City) Hose ( Demand) : 100 D3 - System Demand : 401.567 Safety Margin : 69.319 150 -0+—' 140 - 130 - ______ - -_ C ? ____________ ______________ _________________ p120 R 110 E10° S90 80 U70 0 ) D60 E5° 40 30 20 10 I I I I I I I 300 600 900 1200 1500 1800 2100 2400 2700 - FLOW (NA1.85): Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Advance Fire Protection Co. Page 3 PROGRESSIVE - CLAIMS OFFICE Date 6-6-07 Fitting Legend Abbrev. Name ½ % 1 1% 1% 2 2%. 3 31/2 4 5 6 8 10 1214 16 16 20 24 B Generic Butterfly Valve 0 0 0 0 3 5.5 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E 90 Standard Elbow 2 2 2 3 4 5 6 7 B 10 12 14 18 22 27 35 40 45 50 61 F 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L Long Turn Elbow 1 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 S Generic Swing Check Vlv 4 5 5 7 9 11 14 2 0 22 27 32 45 55 65 76 87 98 109 130 T 90 Flow ThruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Advance Fire Protection Co. Page 4 PROGRESSIVE - CLAIMS OFFICE Date 6-6-07 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea - TYP 9.0 11.2 12.8 na 40.07 0.1 400 12.8 1 11.83 41.37 na 2 11.83 K= K @ ARM 28.75 na 44.92 3 11.83 K = K @ ARM 28.7 na 44.89 5 11.83 41.48 na 6 11.83 K= K@ ARM 23.17 na 40.33 7 11.83 K= K@ ARM 22.87 na 40.07 8 11.83 K= K@ ARM 23.43 na 40.56 10 11.83 42.0 na 11 11.83 K= K@ ARM 29.36 na 45.4 12 11.83 K= K@ ARM 29.34 na 45.39 14 11.83 44.15 na 15 11.83 42.44 na 18 11.83 44.01 na 20 11.83 43.98 na 22 11.83 43.98 na 4 11.83 36.94 na 9 11.83 37.14 na 13 11.83 38.29 na 16 11.83 40.31 na 17 11.83 41.14 na 19 11.83 42.21 na 21 11.83 42.28 na 24 11.83 44.27 na TOR 11.83 47.0 na BOR 0.0 56.09 na 100.0 UG 0.0 56.15 na CITY 0.0 65.4 na The maximum velocity is 14.88 and it occurs in the pipe between nodes TYP and ARM Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Advance Fire Protection Co. Page 5 PROGRESSIVE - CLAIMS OFFICE Date 6-6-07 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c.,or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn TYP 40.07 1.049 1E 2.0 12.000 12.800 K Factor = 11.20 to 120 2T 10.0 12.000 -1.226 ARM 40.07 0.4707 0.0 24.000 11.296 Vel = 14.88 0.0 40.07 22.870 K Factor = 8.38 1 -49.73 1.442 1 7.432 77.250 41.366 to 120 0.0 7.432 0.0 2 -49.73 -0.1490 - 0.0 84.682 -12.621 Vel = 9.77 2 44.92 1.442 0.0 21.250 28.745 K Factor @ node ARM to 120 0.0 0.0 0.0 3-4.81 -0.0020 0.0 21.250 -0.042 Vel=0.94 3 44.89 1.442 2L 4.955 70.000 28.703 K Factor @ node ARM to 120 11 7.432 12.387 0.0 4 40.08 0.1000 0.0 82.387 8.238 Vel = 7.87 0.0 40.08 36.941 KFactor=6.59 5 -60.80 1.442 1 7.432 77.250 41.476 to 120 0.0 7.432 0.0 6 -60.8 -0.2161 0.0 84.682 -18.303 Vel= 11.94 6 40.33 1.442 0.0 10.500 23.173 K Factor @ node ARM to 120 0.0 0.0 0.0 7 -20.47 -0.0289 0.0 10.500 -0.303 Vel = 4.02 7 40.07 1.442 0.0 21.000 22.870 K Factor @ node ARM to 120 0.0 0.0 0.0 819.60.0266 0.0 21.000 0.559 Vel =3.85 8 40.56 1.442 1 7.432 57.250 23.429 K Factor @ node ARM to 120 0.0 7.432 0.0 960.160.2119 -0.0 64.682 13.709 Vel =11.82 0.0 60.16 37.138 K Factor = 9.87 10 - -49.76 1.442 1 7.432 77.250 41.997 to 120 0.0 7.432 0.0 ii -49.76 -0.1492 0.0 84.682 -12.636 VeI= 9.78 11 45.40 1.442 0.0 10.500 29.361 K Factor @ node ARM to 120 0.0 0.0 0.0 12 -4.36-0.0016 0.0 _10.500 -0.017 Vel =0.86 12 45.39 1.442 iT 7.432 78.250 29.344 K Factor @ node ARM to 120 0.0 7.432 0.0 13 41.03 0.1044 0.0 85.682 8.944 Vel =8;06 0.0 41.03 38.288 K Factor= 6.63 14 -27.20 1.682 2T 19.799 54.500 44.154 to 120 0.0 19.799 0.0 15 -27.2-0.0231 0.0 74.299 -1.713 Vel =3.93 15 12.12 1.442 1L 2.477 120.000 42.441 to 120 iT 7.432 9.909 0.0 16 -15.08 -0.0164 0.0 129.909 -2.128 Vel = 2.96 0.0 -15.08 40.313 K Factor= -2.38 15 -12.12 1.442 IT 7.432 112.000 42.441 to 120 0.0 7.432 0.0 17 -12.12-0.0109 0.0 119.432 -1.306 Vel=2.38 0.0 -12.12 41.135 KFactor= -1.89 18 -91.82 3.26 21 40.319 166.500 44.011 to 120 0.0 40.319 0.0 19 -91.82 -0.0087 0.0 206.819 -1.805 VeI= 3.53 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Advance Fire Protection Co. Page 6 PROGRESSIVE - CLAIMS OFFICE Date 6-6-07 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. I.C1.or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 -91.82 42.206 - K Factor = -14.13 20 -11.17 1.442 2T 14.864 166.500 43.984 to 120 0.0 14.864 0.0 21 -11.17 -0.0094 0.0 181.364 -1.706 Vel= 2.19 0.0 -11.17 42.278 KFactor= -1.72 22 -11.08 1.442 2T 14.864 166.500 43.977 to 120 0.0 14.864 0.0 23 -11.08-0.0093 0.0 181.364 -1.680 Vel = 2.18 0.0 -11.08 42.297 K Factor -1.70 4 40.08 2.157 0.0 14.000 36.941 to 120 0.0 0.0 0.0 9 40.08 0.0141 0.0 14.000 0.197 Vel = 3.52 9 60.16 2.157 0.0 15.000 37.138 to 120 0.0 0.0 0.0 13 100.24 0.0767 0.0 15.000 1.150 - Vel = 8.80 - 13 41.03 2.157 0.0 14.000 38.288 to 120 0.0 0.0 0.0 16 141.27 0.1446 0.0 14.000 2.025 Vel = 12.40 16 -15.08 2.157 0.0 7.000 40.313 to 120 0.0 0.0 0.0 17 126.19 0.1174 0.0 7.000 0.822 Vel = 11.08 17 -12.12 2.157 0.0 11.000 41.135 to 120 0.0 0.0 0.0 19 114.07 0.0974 0.0 11.000 1.071 Vel _10.02 19 -91.82 2.157 0.0 15.000 42.206 to 120 0.0 0.0 0.0 21 22.250.0048 0.0 15.000 0.072 Vel _1.95 21 -11.17 2.157 0.0 15.000 42.278 to 120 0.0 0.0 0.0 23 11.080.0013 0.0 15.000 0.019 Vel _0.97 0.0 -11.08 - 42.297 K Factor = 1.70 1 49.73 2.635 0.0 14.000 41.366 to 120 0.0 0.0 0.0 5 49.73 0.0079 0.0 14.000 0.110 Vel = 2.93 5 60.81 2.635 0.0 15.000 41.476 to 120 0.0 0.0 0.0 10 110.54 0.0347 0.0 15.000 0.521 Vel = 6.50 10 49.76 2.635 IT 16.474 16.500 41.997 to 120 0.0 16.474 0.0 24 160.3 0.0689 0.0 - 32.974 2.273 Vel = 9.43 0.0 160.30 44.270 K Factor= 24.09 22 11.08 2.635 0.0 15.000 43.977 to 120 0.0 0.0 0.0 20 11.08 0.0005 0.0 15.000 0.007 Vel= 0.65 20 11.17 2.635 0.0 15.000 43.984 to 120 0.0 0.0 0.0 18 22.25 0.0018 0.0 15.000 0.027 Vel= 1.31 18 91.82 3.26 0.0 11.000 44.011 to 120 0.0 0.0 0.0 14 114.07 0.0130 0.0 11.000 0.143 VeI= 4.38 14 27.20 3.26 0.0 6.000 44.154 to 120 0.0 0.0 0.0 24 141.27 0.0193 0.0 6.000 0.116 Vel = 5.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Advance Fire Protection Co. Page 7 PROGRESSIVE - CLAIMS OFFICE Date 6-6-07 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 24 160.30 3.26 IL 6.72 28.000 44.270 to 120 0.0 6.720 0.0 TOR 301.57 0.0787 0.0 34.720 2.734 Vel = 11.59 TOR 0.0 3.26 is 2.688 10.000 47.004 to 120 iF 4.032 40.319 5.124 BOR 301.57 0.0787 lB 13.44 50.319 3.961 Vel = 11.59 iT 20.159 BOR 100.00 8.249 2L 40.614 15.000 56.089 Qa = 100 to 140 0.0 40.614 0.0 UG 401.57 0.0011 0.0 55.614 0.061 Vel = 2.41 UG 0.0 8.385 6L 149.906 60.000 56.150 to 150 iT 67.266 224.858 9.000 * Fixed loss = 9 CITY 401.57 0.0009 1G 7.687 284.858 0.253 Vel _=_2.33 0.0 401.57 - -- 65.403 K Factor = 49.65 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 tqco /Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB - 28,42,56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain -ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.81K, 1/2NPT TY1231 - Pendent 2.81K, 1/2NPT TY2131 - Upright 4.2K, 1/2NPT TY2231 - Pendent 4.2K, 1/2NPT TY3131 - Upright 5.61K, 1/2NPT JULY, 2004 TY3231 - Pendent 5.61K, 1/2NPT TY4131 - Upright 8.01K, 3/4'NPT TY4231 - Pendent 8.01K, 3/4'NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/p5i112 (40,3 LPM/barl'2) K = 4.2 GPM/psi1/2 (60,5 LPM/barl/2) K = 5.6 GPM/psi112 (80,6 LPM/bar1/2) K = 8.0 GPM/psi1/2 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B TFPI7I .4— Page 2 of 8 ESCUTCHEON 7/16 (11,1 mm) PLATE SEATING ** NOMINAL SURFACE 1/2, MAKE-IN NPT (5m) 1-9/16 (39,7 mm) 'J11V' TFPI7I STYLE 100r20 RECESSED ESCUTCHEON LccrLtL, I UN 6 7/16" (11,1mm) I NOMINAL I MAKE-IN 2-3/16"I _5 WRENCH (55,6 mm) FLATS 1/2" NPT** SSP DEFLECTOR * h— 2-7/8' (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6 - Deflector Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7- Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1I3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16(11,1 mm) STYLE 10or20 PLATE SEATING 1/2" ** NOMINAL RECESSED ssu SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR 7/16" 2-3/16° 1,1 mm) VFLATS OMINAL(55,6 mm) (38,1mm) 2-3/ MAKE-IN 1-1/2" C (55,6mm) SSP DEFLECTOR* 2-7/8 (73,0 mm) DIA. --I 1/2' NPT ** I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT Finishes Bulb ..............Glass Sprinkler: Refer to Table A and B Compression Screw .....Bronze Operation Recessed Escutcheon: White Coated, Deflector .......Copper/Bronze Chrome Plated, or Brass Plated Bushing (K=2.8) .......Bronze The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the Physical Characteristics fluid expands sufficiently to shatter the Frame .............Bronze glass Bulb, allowing the sprinkler to Button .........Brass/Copper activate and water to flow. Sealing Assembly .......... Beryllium Nickel w/Teflonf TFPI71 Page 3 of 8 ESCUTCHEON PLATE SEATING SURFACE 2-3/16' 6 mm) 55,6 mm) 1- (38, 7/16 (11,1 mm) 1/2 ** NOMINAL MAKE-IN NPT STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR / 7/16 / L (11,1 mm) 1 MAKE-IN N tJ CH MAK 2-3/16' WREN NOMINAL I (55,6 mm) FLATS 1/2' NPT** SSP DEFLECTOR* H-- 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2(12,7mm) STYLE 30 or 40 PLATE SEATING 3/4fl ** NOMINAL RECESSED SSU* SURFACE MAKE-IN ESCUTCHEON NPT DEFLECTOR T__ — 1/2" 6* 2-5/16" (12,7 mm) (58,7 mm) NOMINAL L ?2: (39,7 mm) IEIN 2-1 1-9/16 FLATS (57,2 mm) WRENCH SSP DEFLECTOR* 2-7/8 (73,0 mm) DIA. 3/4 NPT ** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler Page 4 of 8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE*** IPOLYESTER 2.8 1/2 PENDENT (TY1231) and UPRIGHT (TY1131) 135°F157°C Orange 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141C Blue NPT RECESSED PENDENT (TY1231)* Figure 5 135°F/57°C Orange 1,2, 5 155°FI68C Red 175°F/79°C Yellow 200°FI93C Green RECESSED PENDENT (TY1231)** Figure 6 135°F/57C Orange 155F/68°C He 175°F/79°C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57°C Orange 1,2 155°F168°C Red 175°F179°C Yellow 200°F/93°C Green 286'F/1 41'C Blue RECESSED PENDENT (TY2231)* Figure 7 135°F/57°C Orange 155°F/68°C Red 175F/79°C Yellow 200°F193°C Green RECESSED PENDENT (TY2231)** Figure 8 1 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C I Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01 -E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2' NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2' NPT) or Style 30 (3/4" NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS held horizontally, a small air bubble A leak tight 1/2 inch NPT sprinkler joint should be present. The diameter of the should be obtained with a torque of 7 air bubble is approximately 1/16 inch to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- (1,6 mm) for the 135°F/57°C to 3/32 mum of 21 ft. lbs. (28,5 Nm) of torque inch (2,4 mm) for the 2861F/1411C may be used to install sprinklers with temperature ratings. 112 NPT connections. A leak tight 314 TFPI7I inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is-to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Reoessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I Page 5 of 8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME I WHITE*** LEAD LIQUID BRASS J PLATED 1POLYESTER COATED 135F/57°C Orange PENDENT (TY3231) and 1,2, 3, 4, 5, 6,7 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3131) 286°F/141°C Blue 1/2" NPT 135°F/57°C Orange RECESSED PENDENT (TY3231)* 1,2, 4,5 N/A 155°F/68°C Red 175°F/79°C Yellow Figure 9 200°F/93"C Green 135°F/57 C Orange RECESSED PENDENT (TY3231)** 1,2,3,4,5 1,2,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow Figure 10 200°F/93°C Green 135°F/57°C Orange PENDENT (1Y4231) and UPRIGHT 1, 2,3,4,5,6,7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 8.0 (TY4131) 286°F/141°C Blue 3/4,, NPT 135°F/57°C Green RECESSED PENDENT (TY4231)* 1,2,4,5 N/A 155°F/68°C Orange 175°F/79°C Red Figure 11 200°F/93°C Yellow 135°F/57°C Orange RECESSED PENDENT (TY4231)** 1, 2, 3,4, 5 N/A 155F/68°C Red 175°F/79°C Yellow Figure 12 1 200°F/93°C I Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4' NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2' NPT) or Style 30 (3/4" NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 8 2-7/8 DIA. - 5/8±1/4' (73,0 mm) 3/4' (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4" (6,4 mm) SPRINKLER PLATE I FACE OF ._57,2 mm) MOUNTING 1/8' FITTING 3,2 mm) 2 _____ ___ _______ 4i / ___ ______ / MOUNTING / 1-5/16' SURFACE/// (33,3 mm) I CLOSURE SERIES .TY-FRB 13/16"(20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4' (73,0 mm) I 3/4'(19,1 mm) (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) I FACE OF mm) MOUNTING SPRINKLER PLATE FITTING I MOUNTING SURFACE SERIES 1-1/4' (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I 2-7/8" DIA. 1/2±1/8' (73,0 mm) 1/2'(12,7mm) E (12,7±3,2 mm) - 21/4" DIA. 1/4' (6,4 mm) I I FACE OF L_57,2 mm) MOUNTING SPRINKLER PLATE I FITTING 1 -7 8 SURFACE i (32 mm) I \ MOUNTIN CLOSURE SERIES 1-5/16' (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. (73,0 mm) 1/2±1/8' I 1/2'(12,7mm) E (12,7±3,2 mm) 2-1/4" DIA. I 1/4' (6,4 mm) I FACE OF 57,2 MM MOUNTING PLATE I SPRINKLER FITTING 1/8' mm) \ MOUNTING SURFACE SERIES 1-1/4(31,8mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFPI7I - 2-7/8 DIA. 5/8±1/4 (73,0 mm) 3/4" (19,1 mm) (159±6,4 mm) 2-1/4 DIA. 1/4 (6,4 mm) FACE OF SPRINKLER 57,2 mm) MOUNTING PLATE FITTING 1/8' (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4' (19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - 5/8±1/4' (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4'(6,4 mm) FACE OF 4R 1 (57,2 mm) MOUNTING I PLATE SPRINKLE FITTING 1/8" (3,2 mm) MOUNTIN CLOSURE SERIES 1-5/16 (333 mm) SURFACE TY-FRB 13/16" (20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 7 of 8 - 2-7/8 DIA. (73,0 mm) 1/2±1/8" 1/2" (12,7 mm) r (1 2,7±3,2 mm) 2-1/4' DIA. 1/4' (6,4 mm) I SPRINKLER PLATE I j FITTING MOUNTING (32 mj FACE_OF 572 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 CLOSURE TYFRB 1"(25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4' DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) / I E MOUNTING SPRINKLER P FITTING (2rrn, T-7-- - MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant Coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END 'B" USED FOR 3/4' NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH local requirements and/or national codes. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W- TYPE 7 RECESSED SPRINKLER WRENCH Page 8 of 8 TFPI7I P/N 57 - XXX - X - XXX I L MODEL/SIN 330 2.8K UPRIGHT (1/2NPT) TY1131 331 2.8K PENDENT (1/2NPT) 1Y1231 340 4.2K UPRIGHT (1/2NPT) TY2131 341 4.2K PENDENT (1/2NPT) TY2231 370 5.6K UPRIGHT (1/2NPT) 1Y3131 371 5.6K PENDENT (1/2NPT) 1Y3231 390 8.0K UPRIGHT (3/4NPT) TY4131 391 8.0K PENDENT (3/4NPT) TY4231 I I I SPRINKLER 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED I 135 155 175 200 286 TEMPERATURE RATING ___________ 135*F/57*C 155°F/68°C 175°F/79°C 200°F/93°C 286*F/141*C * Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEEDAN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- Ordering Procedure staratii local distributor for avail- abftly.indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2 (15 mm) Style 10 Chrome Plated ............P/N 56-701-9-010 White Coated .............P/N 56-701-4-010 White RAL9010*P/N 56-701-3-010 Brass Plated ..............P/N 56-701-2-010 1/2 (15 mm) Style 20 Chrome Plated ............P/N 56-705-9-010 White Coated .............P/N 56-705-4-010 White RAL90I0*P/N 56-705-3-010 Brass Plated ..............P/N 56-705-2-010 3/4 (20 mm) Style 30 Chrome Plated ............P/N 56-705-9-011 White Coated .............P/N 56-705-4-011 White RAL9010*P/N 56-705-3-011 Brass Plated ..............P/N 56-705-2-011 3/4" (20 mm) Style 40 Chrome Plated ............P/N 56-700-9-010 While Coated .............P/N 56-700-4-010 White RAL9010" ...........P/N 56-700-3-010 Brass Plated ..............P/N 56-700-2-010 * Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446