Loading...
HomeMy WebLinkAbout1860 MARRON RD; ; FS060004; Permit12/27/24,12:51 PM FS060004 Permit Data City of Carlsbad Fixed Systems Permit Permit No: FS060004 Job Address: 1860 MARRON RD Status: ISSUED Permit Type: FIXSYS Applied 3/13/2006 Parcel No: Approved: 3/16/2006 Lot #: 0 Reference No.: Issued: 3/16/2006 PC #: Inspector: Project Title: SOUP PLANTATION FIRE SUPPRESSION SYSTEM PLAN CHECK & INSPECTIONS Applicant: Owner: SIMPLEX GRINNELL 9855 CARROLL CANYON RD SAN DIEGO CA 858-740-0100 Fees ($) Add'I Fees ($) Total ($) Balance ($) 120 0 120 0 about:blank 1/1 I I oo 10 DESIGN.- INSTALLATION RECHARGE AND MAI NTENANO MANUAL Ko(000c)4 R-102 RESTAURANT FIRE SUPPRESSION SYSTEM (Standard UL 300 Listed) "ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY (MECHANICAL) RELEASE MECHANIS NOTE AGENT TANK MUST BI ORDERED SEPARATE OR SEE PAGE 3-4 REGULATOR SHIPPING WT. 25 LB. (11 kg) FIGURE 2 000138 - REGULATED RELEASE ASSEMBLY (ELECTRICAL) The ANSUL AUTOMAN Regulated Electrical Release Assembly (Part No. 429856) is identical to the mechanical version except it also contains a factory installed 120 VAC solenoid and electrical switch. The solenoid is used to provide electrical actuation of the release mechanism. The electric switch is used to protect the solenoid by opening the circuit to the solenoid once the system is fired. Additional electrical switches can be added as required for auto- matic equipment and gas shut-off accessories, as well as initiating audible and visual alarms. "ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY (ELECTRICAL). NOTE: AGENT TANK MUST BE ORDERED SEPARATELY OR SEE PAGE 3-4 REGULATOR SOLENOID SHIPPING W7.34 LB. )15 kg) SWITCH SECTION III - SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-1 10-1-02 REV. 3 EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant (1.5 gallon - Part No. 79694 or 3.0 gallon - Part No. 79372) is a potassium-based solu- tion designed for fast knock-down and suppression of grease- related fires. The agent is shipped in plastic containers which pro- vide one complete tank charge. Agent storage life expectancy is twelve years. The distributor must record the batch numbers and date of shipment receipt to be filed with each installation record. "ANSULEX LOW pH LIQUID FIRE SUPPRESSANT 3.0 GALLON 1.5 GALLON SHIPPING WT. 35 LB. (16 kg) SHIPPING WT. 19 LB. (9 kg) 000136 000137 FIGURE 1 REGULATED RELEASE ASSEMBLY (MECHANICAL) The ANSUL AUTOMAN Regulated Mechanical Release Assembly (Part No. 429853) contains the regulated release mechanism, expellant gas hose for agent tank hookup, and enclosure knock- outs to facilitate installing actuation piping; expellant piping; detec- tion system; and additional equipment. This regulated release assembly is used in single, double, and multiple-tank systems and must be mounted to a rigid surface. The release mechanism can be used to interconnect both the actuation and expellant gas lines as required per system design. The regulator is designed to allow a constant flow of gas into the tank at 110 psi (759 kPa) when the system is actuated. The agent tank must be ordered separately. In single, double, and multiple-tank systems, the provided expel- (ant gas hose connects the agent tank to the bottom outlet of the regulator. In double and multiple-tank system configurations, the back outlet of the regulator is used as an expellant gas feed for one additional tank-enclosure or tank-bracket hookup. The enclo- sure contains the required knockouts to facilitate this connection. If a pressure switch is to be attached to the regulator, additional fit- tings are required. The tank (ordered separately) is mounted within the enclosure. The tank contains an adaptor/tube assembly with a burst disc union. The burst-disc helps prevent siphoning of the agent up the pipe due to significant temperature fluctuations in the area where the tank is located. The tank is mild steel and, under normal con- ditions, requires hydrostatic testing every twelve years. The detection and additional equipment required per system design are connected to the release mechanism. The enclosure contains knockouts to facilitate detection and additional hookups. The system can be actuated automatically or manually. Automatic actuation occurs when a fusible link within the detection system separates in a fire condition. Manual actuation of the system occurs when personnel pull on the remote manual pull station pull ring. FIGURE 3 000139 SECTION IX - APPENDIX UL EX. 3470 ULC CEx747 Page 9-1 10-1-02 REV. 5 SYSTEM SELECTION GUIDE NOTE: System options do not cover all conceivable variations. They are listed here as a general guideline to show the most common type arrangement for multiple systems, Based on certain system designs utilizing manifolding, non-manifolding, 3-tank systems, etc., other tank/cartridge combinations can be designed. The combinations below are based on 11 flow, 3.0 gallon tanks and 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when appropriate. Total Tank Type of Carbon Dioxide Nitrogen Flow No.* Quantity System Type of Hardware Cartridge Required Cartridge Required 1-5 1 Single 1.5 Gal. Reg. Release 101-10 (423439) LT-20-R (423429) 6-11 1 Single 3.0 Gal. Reg. Release 101-20 (423441) LT-30-R (423435) 12-16 2 Double 1.5 Gal. Req. Release 101-30 (423443) Double (423493) 3.0 Gal. Additional Tank 17-22 2 Double 3.0 Gal. Reg. Release 101-30 (423443)-- 3.0 Gal. Additional Tank 23-33 3 Multiple 3.0 Gal. Reg. Release 101-20 (423441) 3.0 Gal. Reg. Actuator 101-30 (423443)** 3.0 Gal. Additional Tank 23-27 3 Multiple 1.5 Gal. Reg. Release 101-10 (423439) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank 28-33 3 Multiple 3.0 Gal. Reg. Release N/A (Optional) (2) 3.0 Gal. Additional Tanks 34-38 4 Multiple 1.5 Gal. Reg. Release 101-10 (423439) 3.0 Gal. Reg. Actuator. N/A Double 3.0 Gal. Tank Box 34-38 4 Multiple 1.5 Gal. Reg. Release 101-30 (423443) (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 10130 (423443)*** 3.0 Gal. Additional Tank 39-44 4 Multiple 3.0 Gal. Reg. Release 101-20 (423441) 3.0 gal. Reg. Actuator N/A Double 3.0 Gal. Tank Box 39-44 4 Multiple 3.0 Gal. Reg. Release 101-30 (423443)** (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank 45-49 5 Multiple . 1.5 Gal. Reg. Release 101-30(423443) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator N/A Double 3.0 Gal. Tank Box 45-49 5 Multiple 1.5 Gal. Reg. Release 101-10 (423439) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)-- 3.0 Gal. Additional Tank Based 005 flow numbers for a 1.5 gal. system and 11 flow numbers for a 3.0 gal. system. tanks are manifolded, Only S double tank nitrogen cartridge (Part No. 423493) can be used. If tanks are manifolded, either an LT-A-101-30 nitrogen cartridge (Part No. 423491) or a double tank cartridge (Part No. 423493) can be used. Double (423493) LT-30-R (423435) LT-A-101-30 (423491) LT-20-R (423429) LT-A-101-30 (423491) Double (423493) LT-20-R (423435) LT-A-101-30 (423491) Double (423493) LT-A-1 01-30 (423491) LT-30-R (423435) LT-A-1 01-30 (423491) Double (423493) LT-A-101-30 (423491) Double (423493) LT-A-101-30 (423491) LT-20-R (423429) LT-A-101-30 (423491) LT-A-101-30 (423491) RECESS FOR BLOW OFF CAP LOOP NOZZLE - STAMPING VENDOR CODE (IF PRESENT) INTERNAL CUP STRAINER INSIDE SECTION III - SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-5 10-1-02 REV.4 NOZZLES There are twelve types of discharge nozzles each designed to dis- tribute the liquid agent in a uniform pattern throughout the hazard area: 1. 1W Nozzle 7. 245 Nozzle 2. 1 N Nozzle S. 260 Nozzle 3. 1/2N Nozzle 9. 290 Nozzle 4. 3N Nozzle 10. 2120 Nozzle 5. 2W Nozzle 11. 1 Nozzle 6. 230 Nozzle 12. 1100 Nozzle Although these nozzles are similar in appearance and have certain common parts, the tip of each nozzle is designed for a specific application and must only be used in those areas See Nozzle Application Chart in Section IV - System Design, for individual nozzle usage. 3/8-18 NPT FEMALE THREAD / 0. FIGURE 13 000002 Nozzle Identification Chart Nozzle Nozzle Nozzle Nozzle* Flow Tvpe Part No. Stamoinci No. Nozzle Identification 1W Nozzle 419336 1W 1 Chrome-Plated Body 1N Nozzle 419335 1N 1 Chrome-Plated Body 1/2N Nozzle 419334 1/2N 1/2 Chrome-Plated Body Metal blow-off caps are not allowed with the 1/2N nozzle 3N Nozzle 419338 3N 3 Chrome-Plated Body 2W Nozzle 419337 2W 2 Chrome-Plated Body 230 Nozzle 419339 230 2 Chrome-Plated Body 245 Nozzle 419340 245 2 Chrome-Plated Body 260 Nozzle 419341 260 2 Chrome-Plated Body 290 Nozzle 419342 290 2 Chrome-Plated Body 2120 Nozzle 419343 2120 2 Chrome-Plated Body 1 F Nozzle 419333 1 F 1 Chrome-Plated Body 1100 Nozzle 430912 1100 1 Chrome-Plated-Body Nozzle stamping may contain an additional letter indicating a vendor's Code. SWIVEL ADAPTOR The Swivel Adaptor Assembly, Part No. 418569, consists of a swivel nut, swivel body and swivel ball. All are chrome-plated. The swivel adaptor allows any nozzle to be rotated approximately 30° in all directions. Swivel Adaptors must be ordered as a Swivel Adaptor Shipping Assembly, Part No. 423572 which contains 25 Swivel Adaptors. 3/8-18 NPT FEMALE THREAD PT READ 30 DEGREE ROTATION FIGURE 14 000023 RUBBER BLOW-OFF CAPS The Rubber Blow-Off Cap, Part No. 77676, help keep the orifice of the nozzle free of grease or other substances that could interfere with agent distribution. A retaining strap attaches the blow-off cap to the nozzle. Rubber Blow-Off Caps must be ordered as a Shipping Assembly, Part No. 77695, which contains 50 blow-off caps, or Part No. 77411, which contains 12 blow-off caps. FIGURE 15 020009 METAL BLOW-OFF CAP Two types of metal blow-off caps are available as options to the standard rubber caps. The metal cap can be used in unusually high heat conditions, generally over 400 °F (204 °C). The metal blow-off cap is attached to the nozzle by means of a stainless steel wire which prevents it from falling into the appliance during dis- charge. Shipping Assembly Part No. 79745 contains 10 metal blow-off caps for use on standard, non-swivel nozzles and. Shipping Assembly Part No. 415568 contains 10 metal blow-off caps for use on swivel nozzles. NOTICE If metal blow-off caps are required for upright broil- er or salamander protection, use (2) two 1 N noz- zles (Part No. 56930) instead of 1/2N nozzles. 000A~STAINLFSS STEEL WIRE METAL CAP FIGURE 16 000152 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-28 REV. 3 10-1-02 Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heights Part No. Flow No. Duct or Transition Length - Unlimited 1 - 430912 1100 (Single Nozzle) Perimeter - 50 in. (127 cm) Diameter— 16 in. (40.6 cm) Duct or Transition Length - Unlimited 1 - 419337 2W (Single Nozzle) Perimeter - 100 in. (254 cm) Diameter - 31 7/8 in. (81 cm) Duct or Transition Length - Unlimited 2 - 419337 2W (Dual Nozzle) Perimeter— 150 in. (381 cm) Diameter - 48 in. (122 cm) Electrostatic Precipitator Individual Cell 1 - 419334 1/2N (At Base of Duct) Plenum Length - lOft. (3.1 m) 1 - 419335 iN (Horizontal Protection) Plenum Length - 6 ft. (1.8 m) 1 - 430192 1100 (Horizontal Protection) Width —4 ft. (1.2 m) 1 - 419336 1W Plenum Length —4ft. (1.2 m) 1 - 419336 1W (Vertical Protection) Width —4 ft. (1.2 m) Fryer/Split Vat Fryer** Maximum Size (without drip board) 15 in. (38 cm) x 14 in. (36 cm) High Proximity 1 27-47 in. 419339 230 Medium Proximity 1 20 - 27 in. 419340 245 Maximum Size (without drip board) 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 21 —34 in. 419338 3N Low Proximity 1 13-16 in. 419342 290 Maximum Size (without drip board) 18 in. (45.7 cm) x 18 in. (45.7 cm) High Proximity 1 25— 35 in. 419338 3N (64-89 cm) For multiple nozzle protection of single fryers, see detailed information on Pages 4-12 through 4-14. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-29 10-1-02 REV. 3 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heights Part No. Flow No. Fryer/Split Vat Fryer Maximum Size (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in. x 14 in. (38 cm x 36 cm)) High Proximity 1 27 -.. 47 in. 419339 230 Medium Proximity 1 20 - 27 in. 419340 245 Maximum Size (with drip board) 25 3/8 in. (64.4 cm) x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 -21 - 34 in. 419338 3N Low Proximity 1 13-16 in. 419342 290 Maximum Size (with drip board) 18 in. (45.7 cm) x 27 5/8 in. (70.2 cm) High Proximity 1 25 - 35 in. 419338 3N (64-89 cm) Range Longest Side 1 3Ô-50 in. 419333 1 28 in. (71 cm) (76— 127 cm) Area —336sq. in. 40-48 in. (2168 sq. cm) (102— 122 cm) (With Backshelf) Longest Side (High Proximity) 1 40 - 50 in. 419340 245 28 in. (71 cm) (102— 127 cm) Area — 672 sq. in. (4335 sq. cm) Longest Side (Medium Proximity) 1 30-40 in. 419341 260 32 in. (81 cm) (76— 102 cm) Area - 768 sq. in. (4955 sq. cm) Longest Side (Low Proximity) 2 15 —20 in. 419342 290 36 in. (91 cm) (38 - 51 cm) Area - 1008 sq. in. (6503 sq. cm) For multiple nozzle protection of single fryers, see detailed information on Pages 4-7 through 4-11. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-30 REV. 3 10-1-02 Nozzle Application Chart (Continued) Maximum Hazard Hazard Dimensions Griddle Longest Side (High Proximity) 48 in. (122 cm) Area - 1440 sq. in. (9290 sq. cm) Longest Side (High Proximity) 30 in. (76 cm) Area - 720 sq. in. (4645 sq. cm) Longest Side (High Proximity) 36 in. (91 cm) Area - 1080 sq. in. (6968 sq. cm) Longest Side (Medium Proximity) 48 in. (122 cm) Area - 1440 sq. in. (9290 sq. cm) Longest Side (Low Proximity) 48 in. (122 cm) Area— 1440 sq. in. (9290 sq. cm) Chain Broiler* Longest Side - 34 in. (86 cm) (Overhead Protection) Area— 1088 sq. in. (7019 sq. cm) Chain Broiler Length —43 in. (109 cm) (Horizontal Protection) Width - 31 in. (79 cm) Gas-Radiant Char-Broiler Longest Side - 36 in. (91 cm) Area - 864 sq. in. (5574 sq. cm) Electric Char-Broiler Longest Side - 34 in. (86 cm) Area-6805q. in. (4388 sq. cm) Lava-Rock Broiler Longest Side - 24 in. (61 cm) Area —312 sq. in. (2013 sq. cm) Natural Charcoal Broiler Longest Side - 24 in. (61 cm) Area —288 sq. in. (1858 sq. cm) Lava-Rock or Natural Longest Side - 30 in. (76 cm) Charcoal Char-Broiler Area - 720 sq. in. (4645 sq. cm) Minimum Nozzle Nozzle Quantity Heights 1 30-501n. (76 - 127 cm) (perimeter located) 1 30-50in. (76 - 127 cm) (center located) 1 35-40in. (89-102 cm) (perimeter located) 1 20-30in. (51 - 76 cm) (perimeter located) 1 10-20in. (25 - 51 cm) (perimeter located) 2 10-26in. (25 - 66 cm) 2 1-3in. (3-8 cm) 1 15-40in. (38-102 cm) 1 20-50in. (51 - 127 cm) 1 18-35in. (46 - 89 cm) 419342 290 419335/417332 1 N/1 NSS 419342 290 419343 2120 419336/417333 1W/1 WSS 419335/417332 1 N/1 NSS 419335/417332 1 NIl NSS 419335/417332 1 NIl NSS Nozzle Tip Nozzle Stamping - Part No. Flow No. 419341 250 419335/417332 iN/i NSS 1 18-40 in. 419335/417332 1N/1 NSS (46 - 102 cm) 1 14-40 in. 419338 (36-102cm) Minimum chain broiler exhaust opening —12 in. x 12 in. (31 cm x 31 cm), and not less than 60% of internal broiler size. SECTION III - SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-7 10-1-02 REV. 4 DETECTORS The detector consists of three basic components: the bracket, link- age, and fusible link. (Fusible links are not included and must be ordered separately.) The bracket holds the entire assembly to the mounting surface. The linkage is used to support the fusible link. The fusible link is designed to separate at a specific temperature and release the wire rope, thereby actuating the regulated release mechanism. There are three styles of detectors available: the clip-on style, the hinged style, and the scissor style. The clip-on style allows the wire rope to be strung completely through the detection system conduit and brackets first and the detector linkage assemblies are then clipped on later. The hinged style detector requires the wire rope to be strung to the detector bracket, and then "threaded" through the linkage assem- bly before continuing to the next detector bracket. The scissor style allows the wire rope to be strung completely through the detection system conduit and brackets first and the detector linkage assemblies are then clipped on later. Each style of detector consists of two types of assemblies: The Terminal Detector (Part No. 56838, 15375, or 417368) includes a test link and is placed last in a series of detectors. This detector is sometimes referred to as the end-of-line detector and is thus named because it is at the point at which the wire rope "ter- minates," or is anchored at the detector bracket. Only one termi- nal detector is required per detection system. The Series Detector (Part No. 56837, 15373, or 417369) is any detector located in-line between the regulated release assembly and the terminal detector. When using Part No. 56837 and 56838 style detectors, a total of 12 detectors can be in one detection system: 11 series detectors, Part No. 56837 and 1 terminal detector, Part No. 56838. When using Part No. 15373 and 15375 style detectors, a total of 5 detectors can be in one detection system: 4 series detectors, Part No. 15373 and 1 terminal detector, Part No. 15375. When using Part No. 417368 and 417369 style detectors, a total of 15 detectors can be in one detection system: 14 series detec- tors, Part No. 417369 and 1 terminal detector, Part No. 417368. CUP-ON STYLE - PART NO. 56837 AND 56838 1[ FUSI BLE LINKAGE [j LINK 000157 HINGED STYLE- PART NO, 15373 AND 15375 000150 SCISSOR STYLE - PART NO. 417368 AND 417369 000159 FIGURE 21 PULLEY ELBOWS There are two types of pulley elbows used to change the direction of the wire rope by 90°. Ansul recommends for temperatures not in excess of 700 "F (371 "C). Part No. 415670 has socket ends with set screws for 1/2 in. conduit, and Part No. 423250 has com- pression ring ends also for 1/2 in. conduit. Pulley elbows must be ordered in quantities of 50 as Shipping Assembly Part No. 415671 (socket end type) and Part No. 423251 (compression end type). PART NO. 415670 PART NO. 423250 rTT ",CIS 000160 000161 FIGURE 22 BRACKET / K STYLE 000170 SECTION III— SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-10 REV. 1 10-1-02 REGULATOR TEST KIT The Test Kit Assembly (Shipping Part No. 56972) is required to test the regulator setting and nitrogen flow during 12-year mainte- nance examinations. This will ensure that the regulator is func- tioning properly. BURSTING DISC The R-102 Bursting Disc is installed in the tank adaptor assembly. The bursting disc eliminates the siphoning of the agent up the pipe during extreme temperature variations. The bursting discs are available in packs of 10, Part No. 417911. NOZZLE AIMING DEVICE FIGURE 32 000172 FIGURE 30 000169 FUSIBLE LINK Select correct UL Listed fusible link(s) for installation in detector(s) according to the temperature condition chart below: Fusible Link To Be Used Fusible Shipping Where Link Assembly Temperature Temperature Part No. Part No. Rating Does Not Exceed 415739 (1) 415739(1) 165°F (74°C) 100°F (38°C) 415740(1) 415740(1) 212°F(100°C) 150°F (66°C) 415741 (1) 415744 (25) 280 °F (138 °C) 225°F (107 00) 415742(l) 415745 (25) 360°F (182 °C) 290°F (143 °C) 415743(l) 415746 (25) 450°F (232°C) 360 °F (182 °C) 56816(l) 73867 (25) 500 °F (260 °C) 400 °F (204 °C) The Nozzle Aiming Device, Part No. 551265, is required to prop- erly aim each nozzle to the correct aiming point. The device clamps to the nozzle and emits a small laser light that reflects on the surface that it is aiming at. The nozzle can then be rotated to point at a predetermined aiming point and then tightened to hold that angle. The aiming device requires an adaptor, Part No. 431186, to attach it to the nozzle. The adaptor must be ordered separately. ADAPTOR (ORDER SEPARATELY NOLE- AIMING DEVICE FIGURE 33 006520 STAINLESS STEEL ACTUATION HOSE TEMPERATURE i RATING STAMPED ON The Stainless Steel Actuation Hose s used to connect the actua- FUSIBLE LINK BODY o. tion line compression tees between each pneumatic actuator and . can also be connected end to end. The hose has the same thread. 7/16-20, as the fittings. The actuation hose allows flexibility between the AUTOMAN and each regulated actuator. ML STYLE 500 F (260 C) ONLY 000171 FIGURE 31 MAXIMUM REGISTERING THERMOMETER The Maximum Registering Thermometer, Part No. 15240, is used to indicate the highest normal temperature for the protected area. Once this is established, the correct rated fusible link can be chosen. o. Hose Part No. Length 31809 16 in. (41 cm) 32335 20 in. (51 cm) 32336 24 in. (61 cm) 430815 42 in. (107 cm) Fitting Part No. Description 31810 Male Elbow (7/16-20 x 1/4 in. NPT) 31811 Male Tee (7/16-20 x 7/16-20 x 1/4 in. NPT) 32338 Male Straight Connector (7/16-20 x 1/4 in. NPT) FIGURE 34 MECHANICAL GAS VALVES The mechanical gas valves are designed to shut off the flow of gas to the appliances upon actuation of the regulated release assem- bly. The valves are available in sizes of 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., and 2 in. Ansul style; and 2 1/2 in. and 3 in. Asco style. The valves are rated for natural and LP gas. Both styles are UL Listed. Part No. Description 55598 3/4 in. Gas Valve (ANSUL) 55601 1 in. Gas Valve (ANSUL) 55604 1 1/4 in. Gas Valve (ANSUL) 55607 1 1/2 in. Gas Valve (ANSUL) 55610 2 in. Gas Valve (ANSUL) 25937 2 1/2 in. Gas Valve (ASCO) 25938 3 in. Gas Valve (ASCO) Maximum U Operating Pressure 10 psi (69 kPa) 10 psi (69 kPa) 10 psi (69 kPa) 10 psi (69 kPa) 10 psi (69 kPa) 5 psi (34.5 kPa) 5 psi (34.5 kPa) ANSUL STYLE ASCO STYLE 000184 000165 FIGURE 25 SECTION III - SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-8 REV. 5 10-1-02 PULLEY TEE The Pulley Tee (Part No. 427929) is used to change the direction of two wire ropes by 900. It must be used in areas where the tem- peratures are within the range of 32 OF to 130 OF (0 °C to 54 °C). Pulley tees can be used in mechanical gas valve actuation lines and remote manual pull station lines. Pulley tees cannot be used within a detection line. FIGURE 23 000447 STAINLESS STEEL CABLE The 1/16 in. stainless steel cable is run from the terminal detector, through conduit, all series detectors and pulley elbows, and into the regulated release mechanism trip lever. When any fusible link separates, the tension on the cable is relaxed, and the trip lever actuates the regulated release mechanism. The cable can also be used for mechanical gas valves and remote manual pull stations. The cable is available in Soft. (15 m) (Part No. 15821) and 500 ft. (152.4 m) (Part No. 79653) lengths. REMOTE MANUAL PULL STATION The remote manual pull station (Part No. 4835 or Part No. 54011) is required for manual actuation of the regulated release assem- bly. The remote manual pull station should be mounted at a point of egress and positioned at a height determined by the authority having jurisdiction. Trim rings, Part No. 427074 (pack of 10), are available. PART NO. 4835 (WITHOUT CABLE) PART NO. 54011 (WITH 50 FT. OF CABLE). METAL STAMPED 000165 FIGURE 24 SECTION IV - SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-9 10-1-02 REV. 2 ELECTRICAL GAS VALVES The electrical gas valves are designed to shut off the flow of either natural or LP gas to the appliances upon actuation of the regulat- ed release assembly. The valves are available in sizes of 3/4 in., 1 in., 1 1/2 in., 2 in., and 3 in. The valve is held open by an ener- gized solenoid and upon system actuation, the switch contacts in the regulated release assembly open, thus de-energizing the cir- cuit to the gas valve solenoid, causing the valve to close. Valves are available in 120 VAC and are UL Listed. Maximum Part Operating No. Description Pressure 13707 3/4 in. Solenoid Gas Valve (ASCO) 25 psi (172 kPa) 13708 1 in. Solenoid Gas Valve (ASCO) 25 psi (172 kPa) 13709 1 1/2 in. Solenoid Gas Valve 25 psi (172 kPa) (ASCO) 13710 2 in. Solenoid Gas Valve (ASCO) 25 psi (172 kPa) 17643 3 in. Solenoid Gas Valve (ASCO) 5 psi (34.5 kPa) FIGURE 26 000166 MANUAL RESET RELAY The manual reset relay, Part No. 14702 or Part No. 426151, is required when using an electrical gas valve shut-off system. After the electric gas valve has closed, either due to system actuation or power failure, the valve cannot be re-opened, allowing gas to flow, until the reset relay button is manually pressed, re-energizing the circuit. The reset relay is available 120 VAC. The manual reset relay is also recommended for electrical shut down. ELECTRICAL SWITCHES The electrical switches are intended for use with electric gas valves, alarms, contactors, lights, contractor supplied electric power shut-off devices and other electrical devices that are designed to shut off or turn on when the system is actuated. Switches are available in kits: One Switch Kit, Part No. 423878, Two Switch Kit, Part No. 423879, Three Switch Kit, Part No. 423880, and Four Switch Kit, Part No. 423881. Each switch has a set of single-pole, double-throw contacts rated at 21 amp, 1 HP, 125, 250, 277 VAC or 2 HP, 250, 277 VAC. Mounting hardware and 12 in. (305 mm) long wire leads are provided with each kit. COM C FIGURE 28 001612 ALARM INITIATING SWITCH The Alarm Initiating Switch Kit, Part No. 428311, can be field mounted within the ANSUL AUTOMAN release. This switch must be used to close a supervised circuit to the building main tire alarm panel when the ANSUL AUTOMAN release actuates. This action will signal the fire alarm panel that there was a system actuation in the kitchen area. The switch kit contains all necessary mounting components along with a mounting instruction sheet. The switch is rated 50 mA, 28 VDC. SPACER TOWARD WHEN SPACER AND AUTOMAN SWITCH ARE PROPERLY MOUNTED, THIS DIVIDER MUST BE BEEN THE AND N.C. TERMI- CDM N.C. ALARM INITIATING SWITCH S N.C. FIGURE 29 004890 FIGURE 27 000087 SECTION iii - SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-6 REV. 4 10-1-02 CONDUIT OFFSET ASSEMBLY The conduit offset assembly, Part No. 79825, is used to change direction of the wire rope on detection, mechanical gas valve, and remote pull station lines. The conduit offset assembly can only be used in the area where the conduit attaches to the regulated release assembly. When using the conduit offset assembly, the maximum number of pulley elbows is still allowed. The Conduit Offset Shipping Assembly, Part No. 79825, consists of 6 conduit offsets. CONDUIT COUPLING CONDUIT OFFSET CONDUIT CONNECT( "QUIK-SEAL" ADAPTOR The "Quik-Seal" adaptor is a listed mechanical bulkhead fitting that produces a liquid-tight seal around both distribution piping and detection conduit which runs through restaurant hoods and ducts. The "Quik-Seal" adaptor accepts threaded pipe or conduit. The adaptor is available for 1/4 in. (Part No, 78195), 3/8 in. (Part No. 77284), 1/2 in. (Part No. 77286), or 3/4 in. (Part No. 77288) pipe or conduit sizes. When using with EMT conduit, a conduit con- nector must be installed in each end of the adaptor. The "Quik- Sea!" Adaptor Shipping Assembly must be ordered as stated below: Shipping Assembly Hole Size Size Part No. Qty Required 1/4 in. 78196 24 3/4 in. 3/8 in. 77285 24 1 1/8 in. 1/2 in. 77287 24 1 1/8 in. 3/4 in. 77289 24 1 3/8 in. ADAPTOR BODY GASKET LOCK WASHER NUT "COMPRESSION-SEAL" ADAPTOR This adaptor is a mechanical bulkhead fitting that produces a liquid-tight seal around pipe and conduit when installing distribu- tion piping and detection conduit through restaurant hoods and ducts. The "Compression-Seal" adaptor is a straight-through design requiring no cutting or threading of conduit or pipe. The adaptor is available for pipe sizes of 1/4 in. (Part No. 79148), 3/8 in. (Part No. 79150), 1/2 in. (Part No. 79146), and EMT conduit size of 1/2 in. (Part No. 79152). Each "Compression-Seal" Adaptor Shipping Assembly must be ordered as stated below: Shipping Assembly Hole Size Se Part No. Qty. Required 1/4 in. Pipe / 1/2 in. tube 79149 24 3/4 in. 3/8 in. Pipe / 5/8 in. tube 79151 24 11/8 in. 1/2 in. Pipe 79147 24 11/8 in. 1/2 in. EMT Conduit 79153 24 1 1/8 in. COMPRESSION NUT ADAPTOR BODY LOCK WASHER FIGURE 19 000155 "HOOD SEAL" ADAPTOR ASSEMBLY This adaptor is a mechanical bulkhead fitting that produces a liq- uid-tight seal around 1/2 in. EMT conduit when installing the detec- tion line through restaurant hoods and duct. The adaptor accepts a high temperature pulley elbow and, when used, correctly posi- tions the elbow or conduit in line with the conduit adaptor hole in the detector bracket. The "Hood Seal" eliminates the need for mul- tiple elbows when penetrating the top of a hood when installing the detection line. "Hood Seal" Adaptors are available in quantities of 6 as Shipping Assembly Part No. 423253, SEAL NUT SEAL P VVlO ADAPTOR.____________________ BODY .F I PULLEY NOT PAR ELBOW OF ASSEMBLY) USE ONLY PULLEY ELBOW, PART NO. 423250 GASKET FIGURE 17 NUT 000153 FIGURE 20 000156 FIGURE 18 - 000154 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CE747 Page 4-31 10-1-02 REV. 5 Nozzle Application Chart (Continued) Minimum Maximum Hazard Nozzle Nozzle Hazard Dimensions Quantity Heights Wood Fueled Char-Broiler Longest Side —30 in. (76 cm) 1 14-40 in. Area - 720 sq. in. (36 - 102 cm) (4645 sq. cm) Upright Broiler Length —32.5 in. (82.5 cm) 2 - Width - 30 in. (76 cm) Salamander Length - 32.5 in. (82.5 cm) 2 - Broiler Width - 30 in. (76 cm) Wok 14 in.-30 in. (36-76 cm) 1 35-45 in. Diameter (89— 114 cm) 3.75 - 8.0 in. (9.5 - 20 cm) Deep 11 in. —24 in. (28-61 cm) . 30-40 in. Diameter (89 - 102 cm) 3.0— 6.0 in. (8 - 15.2 cm) Deep Nozzle Tip Nozzle Stamping - Part No. Flow No. 419338 3N 419334 1/2N 419334 1/2N 419341 260 419335/417332 1 N/1 NSS