HomeMy WebLinkAbout2958 MADISON ST; ; FS130025; Permit12/27/24,12:45 PM FS 130025 Permit Data City of Carlsbad Fixed Systems Permit Job Address: 2958 MADISON ST Permit Type: FIXSYS Parcel No: 2033032400 Lot #: 0 Permit No: FS130025 Status: APPROVED Applied 9/10/2013 Approved: 9/23/2013 Reference No.: Issued: 9/23/2013 PC #: Inspector: Project Title: BLUE OCEAN SUSHI ANSUL R102 9-GALLON SYSTEM HAS A CAPACITY OF 33 FLOW POINTS/SYSTEM INSTALLING USES 24 FLOW POINTS. Applicant: AZTEC FIRE & SAFETY 8107 COMMERCIAL ST LA MESA, CA 619-464-5625 Owner: TSAI CHIN LUNG&YU 0 2958 MADISON ST CARLSBAD CA r Fees ($) [Add1 Fees ($) Total(s) Balance ($) 229 0 229 0. about:blank 1/1 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-1 4-1-06 REV. 6 SYSTEM DESIGN The ANSUL R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. Both systems must actuate simultaneously. Each system must be designed and installed per its appropri- ate manual. Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center-to-center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 inches. When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub-sections: Noz- zle Placement Requirements, Tank Quantity Requirements, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quantity and piping requirements. Duct Protection - Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. The R-102 system uses different duct nozzles depending on the size of duct being protected. GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (5-20 cm) into the center of the duct opening, discharging up. See Figure 1. 2 -8 IN. (5 - 20 cm) FIGURE 1 000173 In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maximum, to a point just beyond the damper assem- bly that will not interfere with the damper. Exceeding the maxi- mum of 8 in. (20 cm) in this way will not void the UL listing of the system. Previously listed 3 flow number and 5 flow number duct pro- tection detailed in earlier published manual, Part No. 418087- 06, can also still by utilized. DUCT SIZES UP TO 50 IN. (127 cm) PERIMETER/ 16 IN. (41 cm) DIAMETER '• One 1W nozzle (Part No. 419336) = one flow number 50 in. (127 cm) perimeter maximum 16 in. (41 cm) diameter maximum DUCT SIZES UP TO 100 IN. (254 cm) PERIMETER/ 32 IN. (81.3 cm) DIAMETER One 2W Nozzle (Part No. 419337) = two flow numbers 100 in. (254 cm) perimeter maximum 32 in. (81.3 cm) diameter maximum A 2WH nozzle (Part No. 78078) must be substituted for a 2W nozzle for any installation using Option 2 of the 1.5 gallon sys- tem coverage (duct and plenum protection only). A 2WH nozzle is limited to a maximum of 75 in. (190 cm) perimeter or a maxi- mum diameter of 24 in. (61 cm) of coverage. The chart below shows the maximum protection available from each duct nozzle. Part 3.0 Gallon 1.5 Gallon Description No. System System 2W Nozzle 419337 Maximum Maximum 100 in. (254 cm) 100 in. (254 cm) Perimeter Perimeter 1W Nozzle 419336 Maximum Maximum 50 in. (127 cm) 50 in. (127 cm) Perimeter Perimeter FILE COPY r's I 3 ° SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-5 4-1-06 REV. 4 Plenum Protection The R-102 system uses the 1W Nozzle (Part No. 419336) or the 1 N Nozzle (Part No. 419335) for plenum protection. The 1W noz- zle tip is stamped with 1W and the 1 nozzle tip is stamped with iN, indicating they are one-flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. VERTICAL PROTECTION - GENERAL One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft. (.6 m). After the first nozzle, any additional nozzles must be positioned at a maximum of 4 ft. (1.2 m) apart down the entire length of the plenum. The plenum width must P. not exceed 4 ft. (1.2 m). (The 1W nozzle can be used on single or V-bank filter arrangements.) See Figure 6. FIGURE 6 000197 P. When protecting plenums with the 1W nozzle, two options of cov- erage are available: Option 1: The 1W nozzle must be on the center line of the single or "V bank filter and positioned within 1-20 in. (2.5-51 cm) above the top edge of the filter. See Figure 7. o. Option 2: The 1W nozzle must be placed perpendicular, 8-12 in. (20-30 cm) from the face of the filter and angled to the center of the filter. The nozzle tip must be within 2 in. (5 cm) from the perpendicular center line of the filter. See Figure 8. m) 20 cm) 4UM NOZZLE TIF MUST BE W THIS AREA FIGURE 8 000200 HORIZONTAL PROTECTION - OPTION 1 1 NOZZLE - PART NO. 419335— SINGLE BANK PROTECTION One 1 nozzle will protect 10 linear feet (3.1 m) of single filter bank plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-15 cm) from the end of the hood to the tip of the L nozzle. See Figure 9. II 2-4 IN. -. 10 FT. (3.1 m) "NII (5-10 cm) MAXIMUM 00020 000202 FIGURE 9 20 IN. (51 cm) MAXIMUM 1 IN. (2.5 cm) MINIMUM Ii 20 IN: (51 cm) I MAXIMUM 1 IN. (2.5 cm) MINIMUM FIGURE 7 000199 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-14 REV.5 10-1-02 Range Protection 2-Flow Nozzle High Proximity Application (2-Flow Nozzle): 40 in. to 50 in. (102 cm to 127 cm) above the cooking surface. This high proximity application uses the 245 nozzle, Part No. 419340. The nozzle tip is stamped with 245 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 245 nozzle will protect a maximum cooking area of 672 sq. in. (4335 sq. cm) with a maximum longest dimension of 28 in. (71 cm). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 29 and 30. 245 NOZZLE TIP LOCATION CENTER 0 COOKING SURFACE OR 113/8 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NOZ TO CENTER OF ANY BURNER GRATE :ING 245 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE I 50 IN. (127 cm) MAXIMUM HEIGHT OF 245 NOZZLE I TIP 40 IN. (102 cm) MINIMUM HEIGHT I 0F245 I NOZZLE ! TIP I P. 11. 245 NOZZLE TIP LOCATION CENTER OF J COOKING SURFACE OR 11 3/8 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY BURNER GRATE COOKING AREA ) (:) I -+ COOKING AREA (D i 000766 FIGURE 30 000236 FIGURE 29 NOTICE Four burner grates shown in Figure 30. For sin- gle or double burner grates, locate nozzle at center of cooking surface or 11 3/8 in. (29 cm) maximum from nozzle centerline to center of any burner grate. 11. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-24 REV. 6 4-1-06 0. Gas-Radiant/Electric Char-Broiler Protection The R-1 02 system uses the 1 N nozzle, (Part No. 419335) for gas- 'radiant/electric char-broiler protection. The nozzle tip on the 1 nozzle is stamped with a iN, indicating that this is a one-flow nozzle and must be counted as one flow number. One IN nozzle will protect a hazard with a maximum length of 36 in. (91 cm) and a total cooking area which does not exceed 864 sq. in. (5574 sq. cm). The nozzle tip must be located 15 to 40 in. (38 to 102 cm) above the hazard surface. When using this nozzle for gas-radiant/electric char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking surface. See Figure 51. 40 IN. (102 cm) / MAXIMUM 151N.(38cm) MINIMUM 000257 FIGURE 51 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-9 4-1-06 REV. 8 Fryer - Single Nozzle Protection (Continued) Maximum Area Dimensions - Single Nozzle Fryer Protection (Continued) Max. Size Max. Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location 19.5 in. x 19 in. 19.5 in. x 253/8 in. 290 13 in. to 16 in. See Figure 17 (50 cm x 48 cm) (50 cm x 65 cm) (33 to 41 cm) 19.5 in. x 19 in. 19.5 in. x 25 3/8 in. 3N See Figure See Figure 18 (50cmx48cm) (50cmx65cm) 18 18 in. x 18 in. 18 in. x 273/4 in. 3N 25 in. to 35 in. See Figure 19 (46 cm x 46 cm) (46 cm x 70.5 cm) (64 cm to 89 cm) FRYER FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA ±3 IN. (7.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND ± 1 IN. (2.5 cm) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND AIMED AT THE MIDPOINT OF THE COOKING AREA. FIGURE 17 002286 34 IN. (86 cm) MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA I - —f21 in. (53 cm) - - I I- I MINIMUM <. 1 VERTICAL ' NOZZLE --- FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOK- ING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 18 002287 FT L~__I RIGHTTO-LE 000008 000010 CENTERLINE FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOTE: 3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER. FIGURE 19 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-18 REV. 5 10-1-02 Griddle Protection 2-Flow Nozzle Option 1 - Nozzle Center Located High Proximity Application: 30 in. to 50 in. (76 cm to 127 cm) above the cooking surface. This high proximity application uses the 290 nozzle, Part No. 419342. The nozzle tip is stamped with 290 indicating this is a 2-flow noz- zle and must be counted as two flow numbers. One 290 nozzle will protect a maximum cooking area of 720 sq. in. (9290 sq. cm) with a maximum dimension of 30 in. (76 cm). When using this nozzle for high proximity applications, the nozzle must be positioned within 1 in. (2.5 cm) of the center of the cook- ing surface and pointed vertically down. See Figure 38 and 37. NOZZLE LOCATION COOKING AREA 1 IN. (2 Cm) MAXIMUM COOKING AREA 1 IN. (2 cm) MAXIMUM CENTER LINE OF GRIDDLE SURFACE ± 1 IN. (2 cm) IN ANY DIRECTION Ti 50 IN. I (127 cm) MAXIMUM I HEIGHT I 0F290 NOZZLE TIP I 30 IN. I (76 cm) MINIMUM HEIGHT OF 290 NOZZLE TIP CENTER OF GRIDDLE SURFACE OR A MAXIMUM DIMENSION OF 20.6 IN. (52 cm) FROM NOZZLE CENTERLINE TO FURTHEST CORNER OF GRIDDLE 0. FIGURE 38 000773 FIGURE 37 000244 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-17 10-1-02 REV. 5 Griddle Protection 1-Flow Nozzle The R-1 02 system uses four different nozzles for the protection of griddles. One of the applications requires a 1-flow nozzle and I I three of the applications require a 2-flow nozzle. NOZZLE LOCATION t I 0-2 IN. (0-5cm) High Proximity Application: 35 in. to 40 in. (89 to 102 cm) above I INSIDE PERIMETER 40 IN. Lu— OF COOKING SURFACE (102 cm) the cooking surface. / I MAXIMUM HEIGHT This high proximity application uses the 1 N nozzle, Part No. OF IN 419335. NOZZLE TIP / /:P--- I The nozzle tip is stamped with 1 N indicating this is a one-flow noz- / I 35 IN. (89cm) / / I MINIMUM zie and must be counted as one flow number. I I HEIGHT I EDGE I OF IN I One 1 N nozzle will protect a maximum cooking area of 1080 sq. OF —.1 I NOZZLE TIP I COOKING in. (6968 sq. cm) with the maximum longest side of 36 in. (91 cm). SURFACE I I____________ When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to a maximum of 2 in. (5 cm) inside the perimeter, and aimed to the midpoint of the cooking surface. See Figure 35 and 36. NOTICE When using this type of griddle protection, only 5 flow numbers are allowed on a 1.5 gallon sys- tem and only 11 flow numbers are allowed on a 3 gallon system. [ r -t MIDPOINT ; i COOKING SURFACE h j IN NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN. (0-5cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. FIGURE 35 000241 FIGURE 36 000243 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-13 4-1-06 REV. 6 Range Protection 1-Flow Nozzle The R-102 system uses five different nozzles for the protection of ranges. Two of the design options require a one-flow nozzle and three of the design options require two-flow nozzles. NOTICE A 13 in. (33 cm) diameter wok pan is the largest wok size that can be protected on ranges. When protecting hot top ranges, the entire cooking surface must be protected. Range Protection (1-Flow Nozzle) Single and multiple burner ranges can be protected using a IN nozzle, Part No. 419335. The nozzle tip is stamped with IN, indi- cating that this is a one-flow nozzle and must be counted as one flow number. When using this nozzle for range protection, the maximum length of the burner grates being protected with a single nozzle must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm) per nozzle. When protecting a range, the 1 N nozzle must be located a maxi- mum of 10 in. (25.4 cm) from each burner grate centerline and must be aimed at the center of the cooking surface. See Figure 26. / 40 N. (102 Cm) 10 IN. (25 cm) MAXIMUM When this type of hazard is equipped with a back shelf located above the range top, two protection options are available: One requires a iF nozzle, Part No. 419333, and the other option requires a 260 nozzle, Part No. 419341. Option 1: 1 F Nozzle: When using the 1 F nozzle for range protec- tion with or without back shelf, the maximum length of the burner grates being protected must not exceed 28 in. (71 cm) and the maximum area of the burner grates must not exceed 336 sq. in. (2168 sq. cm). See Figure 27 for nozzle location details. IF NOZZLE SHELF CAN OVERHANG BURNER(S) BY A MAXIMUM OF 11 IN. (28 cm) 20 IN. AIM (51 cm) 40 - 48 . POINT MINIMUM (30.5 cm) (102 122 14 IN. (35.6 cm) FRONT TO REAR (35.6 cm) MAXIMUM MAXIMUM MAXIMUM CENTERLINE iF NOZZLE LOCATED OVER FRONT EDGE OF BURNER GRATE AND ORIENTED SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONT TO REAR CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. FIGURE 27 000238 Option 2: 260 Nozzle: When using the 260 nozzle for range pro- tection with or without back shelf, the maximum length of burner grates being protected must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm). Nozzle must be located on the front edge of the burn- er grates and aimed at a point 10 in. (25 cm) from the back edge of the burner grates. Nozzle must be mount- ed 30 to 40 in. (76 to 102 cm) above the hazard sur- face. See Figure 28. 260 NOZZLE SHELF CAN OVERHANG BURNER(S) It BY A MAXIMUM OF 11 IN. (28 cm) 1 NOZZLE 32 IN. (81 cm) MAXIMUM AIMING POINT 30-401N. I (76.102cm) 18 IN. (45.7 cm) MINIMUM 10 IN. / (25 cm) MAXIMUM 10 IN. (25 cm) FROM BACK OF BURNER GRATES FIGURE 26 FIGURE 28 0002380 BROILER CHAMBER L - - -J FRONT VIEW 000252 FIGURE 50 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-23 4-1-06 REV. 7 Overhead Chain Broiler Protection (Continued) Example No. 1 - Internal broiler size is 24 in. long x 20 in. wide (61 x 51 cm), with an opening of 16 in. x 16 in. (40.6 x 40.6 cm). To determine minimum opening size, multiply the internal length and the internal width by 0.6: Length of opening - 24 in. x 0.6 = 14.4 in. (61 cm x 0.6 = 36.6 cm) Width of opening -20 in. x 0.6 = 12.0 in. (51 cm x 0.6 = 30.5 cm) The minimum allowable opening for overhead protec- tion would be 14.4 in. x 12.0 in. (36.6 x 30.5 cm). This example would be acceptable for overhead pro- tection. Example No. 2 - Internal broiler size is 30 in. long x 24 in. wide (76 x 61 cm) with an opening of 22 in. x 12 in. (56 x 30 cm). To determine minimum opening size, multiply internal length and internal width by 0.6: Length of opening -30 in. x 0.6 = 18.0 in. (76 cm x 0.6 = 45.7 cm) Width of opening - 24 in. x 0.6 = 14.4 in. (61 cm x 0.6 = 36.6 cm) Minimum allowable opening for overhead protection would be 18 in. x 14.4 in. (45.7 x 36.6 cm). Because this broiler has an opening of 22 in. x 12 in., the 12 in. width is below the minimum allowable cal- culated dimension of 14.4 in. (36.6 cm) and therefore would not be acceptable for overhead protection. Upright/Salamander Broiler Protection The R-102 Restaurant Fire Suppression System uses one 1N Nozzle, Part No. 419335, for upright/salamander broiler protection. The nozzle tip is stamped with 1 N, indicating that this is a one-flow nozzle. One 1 N nozzle will protect a maximum hazard area (internal broil- er chamber) of 16 in. (41 cm) deep x 29 in. (74 cm) wide. The single 1 N nozzle must be located directly in line with either vertical edge of the broiler opening, 6 in. (15 cm) to 12 in. (30 cm) in front of the broiler, and 0 in. to 12 in. (30 cm) above the top of the broiler. The nozzle must be aimed at the center of the broiler opening. See Figure 49. VERTICAL EDGE OF BROILER OPENING AIM AT CENTER OF BROILER OPENING FIGURE 49 007128 Upright/Salamander Broiler Protection The R-1 02 system uses two 1/2N Nozzles (Part No. 419334) for all upright/salamander broiler protection. The nozzle tip is stamped 1/2N, indicating that this is a half-flow nozzle. A pair of these noz- zles will equal one flow number. Two 1/2N nozzles will protect a maximum hazard area (internal broiler chamber) of 30 in. x 32.5 in. (76 cm x 82.5 cm). These noz- zles must always be used in pairs on an upright/salamander broil- er. One nozzle must be positioned above the grate and pointed at the back opposite corner of the broiler chamber. The second noz- zle must be pointed down into the center of the drip pan through the open slot. See Figure 50. Note: If metal blow-off caps are required for upright broiler or sala- mander broiler protection, use (2) two IN nozzles, Part No. 419335, instead of 1/2N nozzles. SALAMANDER BROILER 000251 UPRIGHT BROILER I AT CENTER OF BROILER OPENING 1 NOZZLE (PART NO. 419335) 12 IN NOZZLE - LOCATION ZONE (30 crn) 6 IN. (15 cm) 6 IN. (15 cm) SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-12 REV.5 10-1-02 Multiple Nozzle Fryer Protection -Tilt Skillet / Braising Pan Protection for tilt skillets or braising pans is to be based upon the coverage limitations provided for deep fat fryer protection. Refer to Section IV, DESIGN, starting on Page 4-10, for maximum fryer nozzle coverages and maximum fryer nozzle height limitations. Although the maximum 6 sq. ft. total surface cooking area require- ment applies to fryer protection, it does not apply to tilt skillets or braising pans. Each tilt skillet/braising pan protected module must not exceed the fryer limitations for "MAXIMUM SIZE MODULE OVERALL WITH DRIPBOARD" coverage per nozzle as described in Table on Page 4-11. Tilt skillets and braising pans generally utilize a hinged cover. Fryer protection nozzles are to be placed toward the front of the appli- ance to minimize the potential for the tilt skillet or braising pan cover to interfere with the nozzle discharge. See Figure 25. THE NOZZLE IS TO BE PLACED TOWARD THE FRONT OF THE APPLIANCE TO MINIMIZE THE POTENTIAL FOR THE SKILLET OR BRAISING PAN COVER TO INTERFERE WITH THE NOZZLE DISCHARGE. COVER MUST NOT INTERFERE WITH EDGE OF DISCHARGE PATTERN I FOR MINIMUM AND MAXIMUM NOZZLE HEIGHTS, REFER TO FRYER NOZZLE PARAMETERS FRYER NOZZLE USED FOR TILT SKILLET OR BRAISING PAN PROTECTION MUST BE POSITIONED NEAR THE FRONT EDGE OF THE PAN AND AIMED AT THE FRONT TO BACK CENTERLINE OF THE PAN. THE DISCHARGE FROM THE NOZZLE(S) MUST COMPLETELY CLEAR THE PAN COVER WITH AN UNOBSTRUCTED VIEW TO THE BACK OF THE PAN. FIGURE 25 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-27 10-1-02 REV.4 Wok Protection The R-1 02 system uses two different nozzles for the protection of woks. 1. A 260 nozzle, Part No. 419341, will protect a wok 14 in. (36 cm) minimum diameter up to 30 in. (76 cm) maximum diameter. The wok depth must be no less than 3.75 in. (9.5 cm) and no greater than 8 in. (20 cm). The nozzle tip is stamped with 260 indicating that this is a two- flow nozzle and must be counted as two flow numbers. When using this nozzle, the nozzle must be positioned as shown in Figure 56. NOZZLE MUST BE POSITIONED WITHIN 1 IN. (2 cm) RADIUS OF THE CENTER OF THE WOK, POINTED VERTICALLY DOWN 2. A 1 Nozzle, Part No. 419335, will protect a wok 11 in. (28 cm) minimum diameter up to 24 in. (61 cm) maximum diameter. The wok depth must be no less than 3 in. (8 cm) and no greater than 6 in. (15 cm). The nozzle tip is stamped with 1 N indicating that this a one-flow nozzle and must be counted as one flow number. When using this nozzle, the nozzle must be positioned anywhere along or within the perimeter of the wok, aimed at the center, 30 in. to 40 in. (76 to 102 cm) above the hazard surface, as shown in Figure 57. NOTICE When using this type of wok protection, only 5 flow numbers are allowed on a 1 1/2 gallon system, and only 11 flow numbers are allowed on a 3 gallon system. 40 IN. (102 cm) 260 NOZZLE Ti 35-45 IN. MINIMUM DEPTH 3.75 IN. (9.6 cm) (89-114cm) MAXIMUM DEPTH 8 IN. (20 cm) I t 14 IN. (35.6 cm) MINIMUM DIAMETER 30 IN. (76.2 cm) MAXIMUM DIAMETER FIGURE 56 000261 I 301N. (76 cm) MINIMUM DEPTH 3.0 IN. (7.6 cm) MAXIMUM DEPTH 6.0 IN. (15 cm) f 11 IN. (28 cm) MINIMUM DIAMETER 24 IN. (61 cm) MAXIMUM DIAMETER FIGURE 57 000261 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-28 REV. 5 4-1-06 Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. Minimum Maximum Hazard Nozzle Hazard Dimensions Quantity Duct or Transition Length - Unlimited 1 (Single Nozzle) Perimeter - 50 in. (127 cm) Diameter - 16 in. (40.6 cm) Duct or Transition Length - Unlimited 1 (Single Nozzle) Perimeter - 100 in. (254 cm) Diameter - 31 7/8 in. (81 cm) Duct or Transition Length - Unlimited 2 (Dual Nozzle) Perimeter— 150 in. (381 cm) Diameter —48 in. (122 cm) Electrostatic Precipitator Individual Cell 1 (At Base of Duct) Plenum Length - 10 ft. (3.1 m) 1 (Horizontal Protection) Plenum Length - 6 ft. (1.8 m) 1 (Horizontal Protection) Width - 4 ft. (1.2 m) 1 Plenum Length —4 ft. (1.2 m) 1 (Vertical Protection) Width - 4 ft. (1.2 m) Fryer (Split or Maximum Size Non-Split Vat) (without drip board) 14 in. (36 cm) x 15 in. (38 cm) 1 Low Proximity Fryer (Split or Maximum Size Non-Split Vat) (without drip board) 14 1/2 in. (37 cm) x 14 in. (36 cm) 1 Medium Proximity Fryer (Split or Maximum Size Non-Split Vat)* (without drip board) 15 in. (38 cm) x 14 in. (36 cm) High Proximity 1 Medium Proximity 1 Fryer (Non-Split Vat Only) Maximum Size (without drip board) 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 Low Proximity 1 Maximum Size (without drip board) 18 in. (45.7 cm) x 18 in. (45.7 cm) High Proximity 1 * For multiple nozzle protection of single fryers, see detailed information on Pages 4-12 through 4-14. Nozzle Tip Nozzle Nozzle Stamping - Heights Part No. Flow No. - 430912 1W - 419337 2W - 419337 2W - 419334 1/2N - 419335 1 - 430192 1W - 419336 1W - 419336 1W 13—l6in. 419342 290 (33 - 41 cm) 16-27in. 419342 290 (41 - 69 cm) 27-47in. 419339 230 20-27 in. 419340 245 21-34in. 419338 3N 13—l6in. 419342 290 25-35 in. 419338 3N (64-89 cm) 27 - 47 in. 20-27 in. 21 —34 in. 13-16 in. 25-35 in. (64-89 cm) 13-16 in. (33 —41 cm) 16 - 27 in. (41 —69 cm) 30-40 in. (76 - 102 cm) 40-48 in. (102-122 cm) (With Backshelf) 40 - 50 in. (102 - 127 cm) 30-40 in. (76— 102 cm) 15 - 20 in. (38 - 51 cm) 419339 230 419340 245 419338 3N 419342 290 419338 3N 419342 290. 419342 290 419335 1 419333 1 419340 245 419341 260 419342 290 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-29 4-1-06 REV. 5 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heights Part No. Flow No. Fryer (Non-Split Maximum Size Vat Only)* (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in. x 14 in. (38 cm x 36 cm)) High Proximity Medium Proximity Maximum Size (with drip board) 25 3/8 in. (64.4 cm) x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity Low Proximity Maximum Size (with drip board) 18 in. (45.7 cm) x 27 3/4 in. (70.5 cm) High Proximity 'Fryer (Split or Maximum Size Non-Split Vat) (with drip board) 14 in. (36 cm) x 21 in. (53 cm) Low Proximity Fryer (Split or Maximum Size Non-Split Vat) (with drip board) 14 1/2 in. (37 cm) x 26 1/2 in. (67 cm) Medium Proximity Range Longest Side 32 in. (81 cm) Area —384 sq. in. (2477 sq. cm) Longest Side 28 in. (71 cm) Area-336 sq. in. (2168 sq. cm) Longest Side (High Proximity) 28 in. (71 cm) Area - 672 sq. in. (4335 sq. cm) Longest Side (Medium Proximity) 32 in. (81 cm) Area —768 sq. in. (4955 sq. cm) Longest Side (Low Proximity) 2 36 in. (91 cm) Area —1008 sq. in. (6503 sq. cm) For multiple nozzle protection of single fryers, see detailed information on Pages 4-7 through 4-11. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-30 REV 3 10-1-02 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heights Part No. Flow No. Griddle Longest Side (High Proximity) 1 30-50 in. 419341 260 48 in. (122cm) (76-127cm) Area - 1440 sq. in. (perimeter (9290 sq. cm) located) Longest Side (High Proximity) 1 30-50 in. 419342 290 30 in. (76 cm) (76— 127 cm) Area - 720 sq. in. (center located) (4645 sq. cm) Longest Side (High Proximity) 1 35 - 40 in. 419335/417332 iN/i NSS 36 in. (91 cm) (89 - 102 cm) Area— 1080 sq. in. (perimeter located) (6968 sq. cm) Longest Side 1 20-30 in. 419342 290 (Medium Proximity) (51 —76 cm) 48 in. (122 cm) (perimeter Area - 1440 sq. in. located) (9290 sq. cm) Longest Side (Low Proximity) 1 10-20 in. 419343 2120 48 in. (122 cm) (25-51 cm) • Area - 1440 sq. in. (perimeter • (9290 sq. cm) located) Chain Broiler Longest Side —34 in. (86 cm) 2 10-26 in. 419336/417333 1W/1 WSS (Overhead Protection) Area - 1088 sq. in. (25-66 cm) (7019 sq. cm) Chain Broiler Length —43 in. (109 cm) 2 1 - 3 in. 419335/417332 1 N/l NSS (Horizontal Protection) Width - 31 in. (79 cm) (3 - 8 cm) Gas-Radiant Char-Broiler Longest Side - 36 in. (91 cm) 1 15-40 in. 419335/417332 1 N/i NSS Area —864 sq. in. (38— 102 cm) (5574 sq. cm) Electric Char-Broiler Longest Side - 34 in. (86 cm) 1 20 - 50 in. 419335/417332 1 N/i NSS Area —680 sq. in. (51 - 127 cm) (4388 sq. cm) Lava-Rock Broiler Longest Side —24 in. (61 cm) 1 18 —35 in. 419335/417332 1N/1 NSS Area— 312 sq. in. (46-89 cm) (2013 sq. cm) Natural Charcoal Broiler Longest Side —24 in. (61 cm) 1 18 —40 in. 419335/417332 iN/i NSS Area —288 sq. in. (46— 102 cm) (1858 sq. cm) Lava-Rock or Natural Longest Side —30 in. (76 cm) 1 14-40 in. 419338 3N Charcoal Char-Broiler Area —720 sq. in. • (36— 102 cm) (4645 sq. cm) Minimum chain broiler exhaust opening - 12 in. x 12 in. (31 cm x 31 Cm), and not less than 60% of internal broiler size. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-31 3-1-04 REV. 6 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heights Part No. Flow No. Wood Fueled Char-Broiler Longest Side —30 in. (76 cm) 1 14 —40 in. 419338 3N Area —720 sq. in. (36— 102 cm) (4645 sq. cm) Upright Broiler Length —32.5 in. (82.5 cm) 2 - 419334 1/2N Width —30 in. (76 cm) Salamander Length —32.5 in. (82.5 cm) 2 - 419334 1/2N Broiler Width - 30 in. (76 cm) Wok 14 in. —30 in. (36-76 cm) 1 35-45 in. 419341 260 Diameter (89 - 114 cm) 3.75 - 8.0 in. (9.5 - 20 cm) Deep 11 in.-24 in. (28-61 cm) 30-40 in. 419335/417332 1N/1NSS Diameter (76 - 102 cm) 3.0-6.0 in. (8— 15.2 cm) Deep It