Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
965 PALOMAR AIRPORT RD; 106; AS130183; Permit
12/27/24,12:41 PM AS130183 Permit Data City of Carlsbad Sprinkler Permit Permit No: A5130183 965 PALOMAR Job Address: Status: APPROVED AIRPORT RD Permit Type: SPRINK Applied 10/15/2013 Parcel No: 2110403400 Approved: 10/28/2013 Lot #: 0 Reference No.: Issued: 10/28/2013 PC #: Inspector: Project Title: STARBUCKS TI FOR STE 106 Applicant: PACIFIC FIRE SYSTEMS, INC. 13142 NELSON LANE POWAY, CA 858-722-9865 Owner: ME RI PALOMAR PLACE L L C C/O MISSION EQUITIES REAL ESTATE 12838 STEBICK CT SAN DIEGO CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 268 0 268 0 about:blank 1/1 MATERIAL DATA SUBMITTAL STARBUCKS COFFEE PALOMAR PLACE Tenant Improvement 965 Palomar Airport Rd. Ste. 106 Carlsbad, CA 92011 IV A- FIRE SYSTEMS, INC. Pacific Fire Systems, Inc. 12316 Oak Knoll Rd. Suite B Poway, CA 92064 (858) 883-2333 Phone 9 (858) 883-2334 Fax November 15, 2012 Sprinkler 41a N I Kj MICROFASTQ AND I I I ' L RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N industrial Park Drive, Hastings MI 49058 Telephone: 269-9459501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfaste and MicrofastHP Quick Response Pendent Sprinklers are small, thermosensitive glass bulb spray sprinklers available in several different finishes and temperature ratings and K Factors to meet design requirements The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In ad- dition, these coatings have been investigated for installation in corrosive atmos- pheres and are cULus listed as corrosion resistant as indicated in the Approval Chart (Note FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved Classes 2001 2002 2015 and 2017 NYC Approved Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 A fle fl......&it! - - tS - - ID t.enuueu; Certificate u-rut-ru VdS Approved Certificates G4040095 G4040097 G4060056 G4060057 G4880045 G4930038 and G4980021 LPC Approved Ref. Nos 096e/03 and 096e/04 CE CE Certified Standard EN 12259-1 EC certificates of conformity 0786 CPD 40130 0786-CPD-40170 and 0786-CPD 40279 0832 CPD 2001 and 0832-CPD 2003 MED Certified: Standard EN 12259-1, EC-certficate of conformity 0832-MED-1 003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart I and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for 1M Approval requirements that must be followed TECHNICAL DATA Specifications: Available since 1987 Minimum Operating Pressure 7 psi (0.5 bar)* Maximum Working Pressure Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems High-pres- The Viking Corporations Web site at sure (HP) sprinklers can be identified by locating 250" stamped on http llwwwvukinggroupinc corn the deflector. All other Part Nos not mentioned above are rated to a The Web site may include a more recent maximum 175 psi (12 bar) wwp edition of this Technical Data Page Factory tested hydrostatically. to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass bulb fluid temperature rated to 65 F ( 55 C) Overall Length Refer to the Approval Charts cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting Brass UNS C84400 or QM Brass for Sprinklers 066628 and 12282 Brass UNS-C84400 for all other sprinklers Deflector Phosphor Bronze UNS C51000 or Copper UNS-C19500 for Sprinklers 06662B 06666B and 067658 Copper UNS C 19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw Brass UNS C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT coated. Form No. F_081296 Replaces page 41a-f, dated September 19, 2012. (Removed MED from 06662B) A%,5:2 a a Sprinkler 41b November 15, 2012 N 1 1(1 MICROFASTO AND i : i I RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N industrial Park Drive, Hastings MI 49058 Telephone: 289-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP5 Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, ChromeEnloye = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135 "F (57 oC) = A, 155 °F (68 "C) = B, 175 "F (79 "C) = D, 200 "F (93 "C) = E, and 286 "F (141 "C) = G For example, sprinkler VK302with a 1/2" thread, Brass finish and a 155 "F (68 "C) temperature rating = Part No, 06662BA8 Available Finishes And Temperature Ratings Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A Standard Wrench Part No 10896W/B (available since 2000) B Wrench for Recessed Pendent Sprinklers Part No 16036W/B* (available since 2011) C Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No 15915 (available since 2010) *A W ratchet is required (not available from Viking). ""Allows use from the floor by attaching a length of 1 diameter CPVC tubing to the tool Ideal for sprinkler cabinets Refer to Bulletin F_051808 Sprinkler Cabinets A Six-head capacity Part No 01724A (available since 1911) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards 5 OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing The pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire 6 INSPECTIONS, TESTS AND MAINTENANCE Refer, to NFPA25 for Inspection, Testing and Maintenance require- ments 7 AVAILABILITY The Viking Microfast5 and MicrofastHPe Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation 8 GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Fo±s Pt ive Sprinkler Cap 10896 Figure 1: Standard Sprinkler Wrench 10896W1B Sprinkler Wrench - 16036V/B** for I 4 I k instalung recessed pendent sprinklers L i Crefuliy slide the /2' ratchet Is required i wrench sideways around the protective available from Viking). cap, ensuring engage- the ment with sprinkler wrench tos. IL I Figure 2 Wrench 16036W/B for Recessed Pendant Sprinklers November 15, 2012 Sprinkler 41c NIKJ IG® ® MICROFAST AND 4 . MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax- 269-818-1680 Email: techsvcsvikingcorpcom TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient B lb Color CiassLfic.ation Temperature Rating1 Ceiling Temperature2 U Ordinary 135 F (57 °C) 100 °F (38 °C) Orange Ordinary 155 F (68 °C) 100 F (38 °C) Red Intermediate 175 F (79 °C) 150 F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes. Brass, Chrome-Enloy'5, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA 13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction Refer to specific installation standards. 2 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. '--I Sprinkler 41d November 15, 2012 MICROFASP AND MicrofastHPO QUICK NIKJ RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone 269-945-9501 Technical Services 877-384-5464 Fax 269-818-1680 Email techsvcs@_vikingeorp.com Approval Chart 1..(U L) Mlcrotast1 and MicrofastHPe Quick Response Pendant Sprinklers Madmum 175 PSI (12 bar) WWP V Sprinkler Thad size Nominal Overall Listings and AppiovaIs3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metrIc2 f Inches mm cULus4 NYC5 I VdS LPCB I 0 Standard Orifice VK3C)2 1/2 mm 5.6 80.6 2-1/4' 58 AIX, BIY, C4, E4Z AIX, BIY - - - 18021 VK302 1/2J15_mm 5.6 80.6 2-1/4" 58 AIX, B1Y AIX, B1Y A2 A2X, 82? C2X, E2Y" C2X, E2Y14 Large Orifice 066668 I VK352 1 3/4° 20 mm 1 8.0 1 115.2 1 2-3/8" 1 60 1 AIX, BIY, C4, E4Z AIX, B1Y A2 A2X C21' - 06765B VK352 1/2" 15 mm 1 8.0 115.2 2-3/8" 60 1 AIX, 131Y, C4, E4Z AIX, B1Y A2 -- A212 - Small Orifice" 0671889 VK329 1/2 15 mm 2.8 40.3 2-3/16" 56 AIX, B1Y AIX, 81? - -- - - 06720B9 VK331 1/2" 15 mm 42 57 2-1/4" 58 AiX, B1Y AIX, BIY - -- - - 069328 VK331 - 10 mm 4.2 57 2-3/8" 60 - - - A2 -- G3'3 - Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metrIc2 Inches mm cULus4 NYC' VdS LPCB 0 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AIX, B1Y AIX - - - - Maximum 250 PSI (17 bar) WWP Small Orlfic& 1229010 I VK342 1/2" 1 15 mm 1 2.8 1 40.3 1 2-3/16" 56 1 AIX, B1Y AIX - -- I - Approved Temperature Ratings Approved Escutcheons A - 135°F (57 °C), 155 IF (68 "C), 175 IF (79 "C), 200°F (93 Approved Finishes X - Standard surface-mounted escutcheon or B - 135 F(57 °C), 155 "F (68 "C), 175 "F (79 "C), and 200 1 licrofaste Model F-i Adjustable F (93 C) Polyester6-7, Black Polyester'," C - 155 IF (68 "C), 175 IF (79 "C). 200 IF (93 "C), and 286 Black PTFE0 2-Brass,Chrome-Enloy5, White Polyester7, Y - Standard surface-mounted escutcheon or the Viking MicroIast'5 Model F-i Adjustable F (141 C) and Black Polyester7 Escutcheon or recessed with the Viking D - 135 IF (57 "C), 155 IF (68 "C), 175 "F (79 "C), and 286 - Brass and Chrome-Enlo Micromatic5 Model E-1 or E-2 Recessed "F "C) (141 Escutcheon E - 155 IF (68 "C). 175 IF (79 "C), and 200 IF (93 "C) 4- ENT Z - Standard surface-mounted escutcheon F- 155 IF (68 "C), 175 IF (79 "C), and 286 IF (141 "C) or recessed with the Viking Micromatic G - 155 "F (68 "C) Model E-i Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K4actor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S and Canada. 5Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant Other colors are available on request with the same Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. 17Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40279. 13 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-401 30 and 0786-CPD40170 '14,€ MED Certified, Standard EN 12259-1. EC-certificates of conformity 0832-MED-1003 and 0832 MED-1008. V--V 1-3/4' \INU/1 (44,5 mm) -'-- —s Maximum 1-1/8' (286 mm) Minimum 2' \IK fl (508 mm) L, Maximum 1-1/8' (28,6 rim) Minimum November 15, 2012 Sprinkler 41e MICROFASP AND N KJ IIG Microfasti-IF16 QUICK SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESIGN CRiTERIA -_UL - •iso rxfcr toAppr&val Chart 1 on page 41a) - cULus Listing Requirements: Microfastx and MicrofastHP' Quick Response Pendent Sprinklers are cUl.us Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small o,ifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F 091699 - Care and Handling of Sprinklers. Also refer to page Q111-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size' 2-5/16' (58.7 mm) minimum 2-1/8' 2-1/2' (63.5 mm) mOXInUM (54 mm) (i5 mm) NPT -__ I I mWal Maximu 9llEElmm) (44.5 mm) (5 Minimum Installed with t Pendent Sprinkler standard 1/8' SUrfaCe 06662B (VK302) mounted escutcheon. Installed with a Microfos-t Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon -- Installed with a Micronia'tic Model E-1 Recessed Escutcheon Installed with a thread on Model E--2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons 4VV' p Sprinkler 41f November 15, 2012 NG MICROFAST5 AND NIKI A I.rIr.n ,1A'IvA MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269818-1680 Email: techsvcs@vikingcorp.com Approval Chart (FM) V Microfast Quick Response Pendent Sp4inkler 115 PSI (12 bar) WWP Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Base Part No SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches _d mm Standard Orifice 06662B VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A2X, B2Y, C3, D3Z 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A2X, B2Y Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 AiX, B1Y, C3, D3Z 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 AiX, B1Y, C3, D3Z Small Orifice4 06718B6 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AiX Approved Temperature Ratings Approved Escutcheons A- 135 "F (57 "C), 155 "F(68 "C), 175 "F(79 "C), X- Standard surface-mounted escutcheon orthe Viking 200 "F (93 "C), and 286 "F (141 "C) Approved Finishes Microfast6 Model F-i Adjustable Escutcheon B - 135 F (57 "C), 155°F (68 "C). 175°F (79 "C), I - Brass and Chrome_Enioye V - Standard surface-mounted escutcheon or the and 200 "F (93 "C) 2- Brass, Chrome-Enloy5, White Polyester5, Viking Mtcrofast5 Model F-i Adjustable Escutcheon C- 155 "F (68 'C), 175 "F (79 "C) 200 'F (93 'C), and Black Polyester" or recessed with the Viking Micromatid5 Model E-1 and 286 "F (141 "C) 3 - ENT or E-2 Recessed Escutcheon 0 - 155 °F (68 'C), 175 "F (79 "C), and 200 'F (93 C) Z - Standard surface-mounted escutcheon or recessed with the Viking Micromatic5 Model E-1 Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 100. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. The sprinkler orifice is bushed. V V V , V DESIGN CRITERIA - FM V tJeo refer Li' Appioval Char: 2 above)V V FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements. hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. tSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to (ethnical data page 13 la-c for Intermediate Level In-Rack Sprinklers, IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance Information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form NO. F081296 Replaces page 41a-f, dated September 19, 2012. (Removed MED from 0666213) IMC0RP0 RATED CORONA. CA' (909) 77-5599 53 .. FIG. 99 ALL THREAD ROD CUT TO LENGTH Size Range - 3/8 thru 7/8 inch rod in 1 inch increments. Material - Carbon Steel Maximum Temperature 750°F Finish Plain Electro Galvanized, and Stainless Steel, . . .. MAX REC. LOAD LM. Order By - Figure number, rod diameter, rod . . ROD FOR SERVICE TEMPS. SIZE o50F 750F length, and finish 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4. 2710 2420 7/8 3770 3360 FIG. 100 ALL THREAD ROD FULL LENGTHS Size Range 1/4 thru 1-1/2 inch rod In 10'-0" lengths I L . . Material - Carbon Steel . MAX. REC. LOAD LBS. APPROX. ROD FOR SERVICE TEMPS WEIGHT Maximum Temperature 750°F SIZE 650 *F 750 *F PER 100 FT Finish - Plain, Elect ro- Galvanized, and Stainless 1/4 240 215 12 Steel 3/8 1 61 Order By Figure number, rod diameter, and 1/2 1130 1010 53 finish /8 1)QQ 3/4 2710 2420 123 '1 0 flfl!Ifl 'I0Cfl ItO 1 4960 4420 .222 14 • 80Q 7 (I 1-1/2 11630 10370 510 When you specify Allied Schedule-i O/Scheduie-40 - M-COAT sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 - M-COAT gives you the extra quality assurance you demand. Our Sch-1 0 (11/4"_ 8") pipe and Sch-40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. ® Galvanized Pipe Schedue- 10/Schedule-40 - M-COAT product can be hot dips galvanized to meet FM requirements specifications of ASTM A-i 23. NPS Nominal Nominal I.D. In;rnm O.D. In; mm In; mm I M-COAT Specifications Nominal I wt. wt. (H20 Filled) CRR I Wall In; mm Lbs/Ft; kqlm LbsJFt kg/m 1"1.315 '33A 1.049 0.133 1.680 _______ 2.05 1 for dry systems in accordance with the zinc coating i387 _____________ 05 11/4 1.380 0.140 2.270 2.93 1 -1 -3,3977 11/2 1,900 483 1.610 0.145 2.720 - 3.61 1 40 40 T 4.0 Thr 2" 2.375 6O3, 2.067 0.154 3.656 j 4 _- 5.13 [_7.63 1 - 172 ' 21/2" 2.875 2.469 0.203 5.80 7.86 1 I65 ri 1w - NPS ' M-COAT Nominal 'Nominal I.D. O.D. In; mm In; mm Specifications Nominal Wt. lWt. (H20 Filled)' CRR Wall in; mm Lbs/Ft; kg/rn Lbs/Ft; kg/rn - 11/4 1.442 0.109 1.810 2.525 7.0955 ir -wr "-m- ir- m 11/2 'S3 1.682 27 ' 0.109 77 2.09 31 " 3.04 5.6570 - --r;i-- 2.375 2.157 0.109 2.640 4.22 4.5827 50 60.3 54.8 2,77',3.9 . 6.28 - 21/2" 65 2.87 v" 73','6f 2.635 9 0120 Q5' 3.530 5.89 77 3.5196 35(ñ r889 3.260 0.120 4.34 7.94 2.5550 r 82 305 64 1182 il or 4.500 114 4.260 i'0826 0.120 305 5.62 83 11.78 - 1.6020 5.563 5.295 0.134 7.78 17.33 1.4874 125 141.3 134.5 3.40' - 11.58. 25.80, - 71 56_1683 6.625 6.357 1615 0.134 '340 9.3 138 23.03 3427 1.0251 8" 8.625 8.249 0.188 16.96 40.15 1.8365 200 7-i19 209 50 ® Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit fire sprinkler pipe products up to 4.500" in diameter are coated with M-COAT, an advanced MIC coating that is FM approved for use in hybrid sprinkle systems. f American made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. ® Specifications & Approvals Schedule-1 O/Schedule 40- M COAT pipe are in compliance with the following: ASTM A-i 35, Type E Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com " "~ a ie d 16100 S LathropAve. • 11350 Norcom Rd. • 2525 N 27thAve. TUBE & CONDUIT" Harvey, IL 60426 1Philadelphia, PA 19154 Phoenix, AZ 85009 4 PART OF atkOfe 02013 Aikore International, Inc. All Rights Reserved. STP-S4-3-1301 6w4@65 ed.0 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-1O/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1".- 8") pipe and Sch-40 (1"- 2'4") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized - Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. VIiIIdtIIIT1IiI.! Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. m -f .11 A1i,',l Sch-40 Specifications NI'S Nominal I.D. Wt. M. (1120 Filled) Pcs/ WI/Lift (21) WliUft (24) WI/LIlt (25') In; mm In; mm Lbs,R; Kg/rn Lbs,Ff; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1W 1.380 2.270 2.93 51 2,431 2,778 2.894 .32 35.1 4.36 4.36 51 1,103 1,260 1,313 1/2' 1.610 2.720 3.61 44 2,513 2.872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2' 2.067 3.650 5.13 30 2,300. 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 . 11.73 19 1,048 1,197 1,247 Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the Onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American MFTr- Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule- 10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following Sch-10 Spec if ications- NI'S Nominal I.D. WI. Will; (H20 Filled) Pcsl WI/LIft (21') WI/Lift (24') WI/Un (25') In; mm In; mm Lbs/Ft; Kg/rn LbsiR: Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1/4' 1.442 1.810 . . 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1/2' 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2/2' 2.635 3.530 5.89 30 21224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 LCL. Welded Outlets Hydrostatic Pressure Side Wall Rupture Listed Approved Listed Vibration Test tqco/F/ow Control ) %eCJ 16100 S. Lathrop Harvey, IL 60426 11350 Norcóm Rd.' Philadelphia, PA 19154 Customer Service: (800) 8825543 TUBE & CONDUIT 2525 N. 27th Ave. - Phoenix, AZ 85009 Fax 708-339-1806 S5-3 SMITH ...COOPER <@> <@> INTERNATIONAL Ductile Iron Threaded Fittings U * ALL FITTINGS 100% AIR TESTED *ASME / ANSI B16.3 DS * ISO 9001:2000 MANUFACTURER * ASTM A536 Grade 65,45,12 LISTED * LISTED/APPROVED AT 500 PSI * ASME/ ANSI B 1.20.1 APPROVED fliwfilp Irnn qo Fihow Ductile Iron Coulin Figure 35E Wgt - A 1/2 3/4 1 1.50 0.64 1-1/4 SizeI 1-1/2 2 2-1/2 Figure 35RE Size T" T Wgt 3/4x112 .22 1.20 0.33 1 x 1/2 1.36 1.26 0.44 1x3/4 1.45 1.38 0.53 1-1/4x112 1.53 1.34 0.64 1-114x314 1.631 1.45 0.75 1-1/4x1 1.671 1.58 0.77 1-1/2 x 1/2 1.7 T 52 0.90 I I 1-1/2 x 3/4 1.75 1.52 0.95 1-1/2 x 1 1.80 1.65 0.99 1-1/2x1-1/4 1.88 1.82 1.14 1 2x1/2 1.97 1.60 1.35 x3/4 1.97 1 1.60 2 x 1 2.02 1.73 2x1-1/4 2.10 1.90 2x1-1/2 2.16 2.02 M58 2-112 x 1-1/2 2.51 2.16 x2 2.60 2.39 Ductile lion Brass Seat Union Figure 35U Size 1/2 1.88 0.47 II 1TP l A ' YE71T ...._t 12.19 1.08 1-1/4 2.50 1.54 1-1/2 2.62 2.03 2 3.121 3.15 Ductile Iron Tee Figure 35T A Wgt -A- -A--' i 1 .._..... I J L 1.30 I 1/2 1.13 i35 3/4 1.31 0.50 1-1/4 1.75 1-1/2 1.94 1.63 2 2.25 2.63 2-1/2 2.70 4.55 Figure 35CP Size A Wgt A 1/2 1.38 0.18 3/4 1.63 0.26 i ____ 1.75 1-1/4 2.00 0.54 1-1/2 2.1910.71 2 2.621 1.15 2-1/2 3.00 1 2.29 Ductile Iron Cap Figure 35C Size A Wgt 4 A + con 12-1/2 1/2 0.87 0.15 3/4 0.97 0.22 1 1.16 0.33 1-1/4 1.28 0.54 1-1/2 .33 0.68 2 1.45 0.96 1.70 1.80 Figure 35HB Size T Wgt II Jl A + I x 1/2 1.06 0.22 1x3/4 1.06 0.18 1-1/4 x 1 1.19 031 1-1/2x1 1.25 0.53 1-1/2x1-1/4 1.25 0.35 2 x 1 138 0.75 2x1-1/4 1.38 0.69 2x1-1/2 1.38 0.62 Figure 35F Size A WT jA- A __ 1/2 0.88 0.22 3/4 0.98 0.33 1 1.13 0.48 1-1/4 1.29 0.73 1-1/2 1.44 0.93 2 1.69155 2-1/2 1.95 2.70 Ductile Iron Beam Clamps Figure 35SF Size A 3/8 0.75 0.31 1/2 0.751 0.54 Ductile lion Reducing 900 Elbow Ductile lion Hex Bushinv A W Ductile Iron 450 Elbow SMITH- COOPER INTERNATIONAL Ductile Iron Threaded . Fittings C(D US * ALL FITTINGS 100% AIR TESTED * ASME tANS! B16.3 * ISO 9001:2000 MANUFACTURER * ASTM A536 Grade 65,45,12 FM LISTED * LISTED/APPROVED AT 500 PSI * ASME/ ANSI B 1201 APPROVED Ductile lrnn Bull 13eud Tee Ductile Iron Reducing Tee Figure 35RT Figure 35BT F-H--Ut Size A B C wgt 3/4x314x1 1.45 1.45 1.57 0.68 lxlxl-1/4 1.67 1.67 1.58 0.97 1 x 1 x 1-1/2 1.80 1.80 1.65 1.14 1-1/4xlx1-1/2 1.88 1.80 1.82 1.43 1-1/4x1-1/4x1-1/2 1.88 1.88 _1.82 1.52 1-1/4x1-114x2 2.10 2.10 1.90 2.00 1-1/2 x 1-1/4 x 2 2.16 2.10 2.02 1.94 1-1/2 x 1-1/2 x 2 2.16 2.16 2.02 2.00 2 x 2 x 2-1/2 1 2.60 2.60 2.39 3.67 Figure 35RC Size X wgt ' 1x1/2 1.69 0.40 1x3/4 1.69 0.38 1-1/4x3/4 2.06 0.53 2x1(nothex) 2.81 0.53 Ductile Iron Cross & Reducing Cross Figure 35X Size A I B Wgt _1 150 1 150 097 1-1/4 1.75 1.75 1.59 1-1/2 1.94 1.94 1.89 2 2.25 2.25 2.93 - Figure - a Size - 1-1/4x1 167 158 125 1-112x1 1.80 1.65 1.48 x 1 2.02 1.73 2.64 fliwHle lrnii Pliwc Figure 35SF Size : I I A 1/2 0.94 0.10 1 1.25 0.28 1-1/4 1.37 0.50 11-1/2 1.44 0.70 2To Size A . Wgt 314x314x112 T .1.20 1.22 0.46 1x1l2x1 .1.50 1.36 1.50 0.70 1x314x314 1.38 1.311.45 0.68 I x 3/4 x 1 1.50 1.45 1.50 0.77 1x1x1l2 1.26 1.26 1.36 0.66 1xlx3/4 1.38 1.38 1.45 0.73 1-1/4x1/2x1-1/4 1.75 1.53 1.75 1.04 1-1/4x3/4x1-1/4 1.75 1.62 .1.75 1.09 1-114x 1 x 1/2 1.34 .26 1.53 0.81 1-1/4x1x3/4 1.45 1.38 1.63 0.90 1-1/4xlx1 1.58 1.50 1.69 1.03 1-1/4x1 x1-i/4 1.75 1.69 1.75 1.10 1-1/4x1-1/4x1/2 1.34 1.34 1.53 0.87 1-1/4x1-1/4x3/4 1.45 1.45 1.62 0.96 1.58 1.67 1.10 1 1/2 x 1/2 x 1-1/4 T7 i-1/2x1/2x1-1/2 T! T 1-1/4x1-1/4x1 .r1.58 1.4 1-1/2x3/4x1-1/4 1.66 1.94 1.66 1.88 1.42 1-1/2x3/4xl-1/2 . 1.75 .1.94 1.47 1-1l2x1x.112 1.44 1.25 1.69 0.97 1-1/2x1x3/4 1.50 1.44 1.75 1.14 1-112x lxi 1.65 1.50 1.80 1.14 1-1/2xlx1-1/4 1.82 1.67 1.88 1.47 1-1/2x1x1-1/2 1.94 1.80 1.94 1.52 1-1/2x1-1/4x1/2 1.41 1.34 1.66 1.03 i-1/2x1-i/4x3/4 1.52 1.45 1.75 1.10 1-1/2x1-1/4x1 . 1.65 1.58 1.80 1.31 1-1/2x 1-1/4 x 1-1/4 .82 1.75 1.88 1.52 1-1/2x1-1/4x1-1/2 .94 1.88 1.94 1.50 1-1/2x1-1/2x1/2 1.41 1.41 166 1.14 1-1/2x1-1/2x3/4 1.52 1.52 1.75 1.23 1-1/2x1-1/2x 1 1.65 1.65 1.80 1.38 1-1/2x1-1/2x1-1/4 1.82 1.82 1.88 1.50 2x1x2 7 T T 2x1-114x2 2.25 2.10 2.25 2.31 2 x 1-1/2 x 1/2 T T7V 1T T 2x1-1/2x3/4 1.60 1.52 1.97 1.61 2x1-1/2x1 1.73 1.65 2.02. 1.65 2x1-112x1-l/4 1.90 1.82 2.10 2.03 2x1-1/2x1-1/2 2.02 1.94 2.16 2.37 2 x 1-1/2 x.2 2.25 2.16 2.25 2.53 x2x1/2 .. 1.49 1.49 1.88 1.50 2 x 2 x 3/4 T T0 T7 T7 2.02 1.91 2.10 2.05 2.16 2.11 Ductile Iron Hex Reducing Coupling x2x 1 1.73 1.73 x2xl-1/4 1.90 1.90 2x2x1-1/2 2.02 2.02 IPS CARBON 5WEL PIPE 100E CUT PRODUCTS 10.52 crecC) utIetT STYLE 922 DIMENSIONS ,. . . ,- Y-__--_-_l Z__.1 --* aW ,6. ½ 11/4 130 183 1.10 3.87 256 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 Y4 1~. 128 1,83 1.10 3.87 2.56 1.1 20 30.2 32.5 . 46.5 27.9 98.3 65,0 0.50 1 141. 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 . 38.6 55.4 27.9 98.3 65.0 034 1V. ½ X 114. 1.42 1.95 1.22 4.08 2.56 1.2 40 30.2 36.1 49.5 31.0 103.6 65.0 0.54 6. 20 , 141. 1.40 1.95 1.22 4.08 2.56 1.2 30.2 35.6 49.5 31.0 103.6 65.0 0,54 1 PM 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 . 58.4 31.0 103,6 650 0.59 141. 1.66 2.19 1.46 4.60 2.56 1.3 50 ,' 30.2 . 42.2 55.6 37.1 116.8 65.0 0.59 ~ 1 3M 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 PM 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37,1 116.8 65.0 0.68 255 ½ 141. 1.91 . 2.44 1.71 5.40 2.56 1.6 65 15 302 48.5 620 43.4 137,2 650 0.73 ~4 141. 1.89 2.44 1.71 5.40 2.56 1.6 20 301 48.0 62.0 43.4 137.2 65.0 0.73 1 1 114. 2.13 . 2.79 1.71 5.40 2.56 1.6 25 , 30.2 54.1 70.9 43.4 . 137.2 65.0 0.73 ½ 76.1 mm is 1 1 3M 30.2 , ' 1.91 48.5 2.44 62.0 1.71 43.4 5.50 139.7 236 65.0 1.6 0.73 ~ 1416 1.89 . 2.44 1.71 ' 5.50 2.56 1.6 20 30.2 48,0 62.0 43.4 139.7 65.0 0.73 1 ' 1/1$ 2.13 ' 2.79 1.71 5.50 2.56 1.7 25 30.2 . 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. _!?La 1kC 1O,2 2 REV G TOLCO tNQOPOATtL) CORONA. CA • (g) 15 FIG. 2 ADJUSTABLE RING HANGER FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range - 1/2 thru 6 inch pipe. Material - Carbon Steel, Mu. Galvanized to G-90 specification. Function - For general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed, Approvals - Underwriters Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 10, and Manufacturers Standardization Society SP-69, lvpe 10. Maximum Temperature - 650°F Finish - Mil. Galvanized and Stainless Steel. Order By Figure number and pipe size. MAX. APPROX. WEIGHT PER 100 PIPE ROD STOCK REC. FIG. 2 SIZE SIZE A B C SIZE LOAD LBS. FIG.2 NFPA - 1/2 3/8 3.1/8 2.5/8 1-3/8 169ax1 400 17 17 4, S/8 34J i2 U/S -6gax1 400 3.7 , , ., 1 3/8 3-3/8 2-5/8 1-1/8 169ax1 400 18 18 .8/4 . 7/S 1J/8 1g 1 400 -._ . 1-1/2 3/8 3-7/8 2-7/8 1 169a x 400 21 21 2 , /S &1J4 6g1 400 23 2-1/2 1/2* -3/4 4-1/4 1-5/8 149ax1-3/16 600 41 40 1 1/4 1 8/16 3-1/2 1/2* 7.3/8 5.1/4 2.1/8 14g 1-3/16 600 52 50 I4cU/4 1000 5 5/8'k 9 6-1/8 2-1/4 129ax1-1/4 1250 97 95 l2gaxll/4 1250 139 3/8" nut is used when NFPA rod sizing is requested. 1/2' nut is used when NFPA rod sizing is requested, 1,. .. SAMN:YS® FOR WOOD A Not less than 2' nominal width Wood Flouting • No pie-drilling required. 4l1.1l2/ 11=1 A Quick to install using the Sammy i Nut Driver with an 18V cordless Not less than 3' nominal il-tickness (2.117) (depth of side Saves time from traditional of vertical member) Double Sheelrock coiling • Reduces installation costs. Made in the U.S.A. recommended imallalion point. a lei 25-380. 7boiavailable on Page 11 - W5ho aiOo demnilmhan t hlw?J!www.itwbui!dex.com - ..,•-. - 114 8002957 GST 100 1/4x 1" W WOSB) 25 125 1/4 8003957 •. GST 200 114x2' 10 (FIr) -. 25. 125 114 8004957 GOT 3013 V4 3" 2060 (Fir) 25 125 210 (7116- OSB) 1 3/8 8007957 GOT 10 1/4 x i 300:.25 125 3/8 8008957 ' GST 20 1/4 x 2' 1760 (Fir) 850 1415 25 125 80689 3/8 25. . GST 20-SS 1/4 x 2 1760 (Fir). 850 ;.-• . 25 125 It. 3/8 8009925 GST 25-380 38 x 21 2" 2113 (Fir) 1500 25 125 #14 Black -. . 3m' :- 8p10957 GST 30 1/4 3 2060 Fir) 2500 .. 1475. '. '.• 25 125 Nut Driver 3/8' 8069925 GST 30-OS 1/4u 3" 2060 (Fir) 25 125 Part-#8113910 — . 3181, 8011925 •G0140 , .114x'4 .2180 pr) .• .. . ' ' 25 . 125 1/2 8013925 GST2 1/4x2" 1760 (Fir) 25 125 1/2 8014925 GST 25380 3/8x2-112'. 2113 (Fir) 25 125 - 1/2" 8015925 GST3 1/4x3" 2275 (Fir) 25 125 i/t4 SW Rd Ntil Driver Pad et 811413 10 MADE IN U.S.A ,, SPECIAL NUT DRIVER SYSTEM The nut drivers were designed with a unique spin-off feature which provides a last and safe installation each time, When the lace of the delver comes Into contact with the material you are installing into, continue drilling until nut driver spins tree Installation is then complete Warranty requires the use of the appropriate nut driver for installations. i #14 SW Re Nut Driver Part #8114910 May require pie-drilling consult joist manufaclurer. sm Application J2TIIlltI(,It4 Not lens than 2" nominal width No pie-drilling required. (1-1/2") opts 3-1/2" pipe; not lens than 3 (2-1/7) nominal width 4 & 5" pipe Quick to install using the Sammy 4 Floor Joot Nut Driver with an 18V cordless drill/driver. Minimum 2-1/2 from bottom for _______ branch lines. Minimum 3" from bot- tom for main tines. Exception. This Saves time from traditional requirement shall not apply to 2" or methods. thicker nailing strips resting on top of steel beams Reduces installationcosts. FhTYIrT1DJI Product Features I 0 MWD Biminates distortion of threaded rod. MaxaaerLE8Y • Made in the U.S.A. Approvals Rod Part Model Size Number SWIVEL MOUNT 41 ac Diver ..J 318" 8139957 SH-GST2O 1/4x2" 1257 (Fir) 1050 Nut Part#8113910 L.... I 3/8"" 8269957 SH-GST/CST 20 5/16x 1-314 1406© 45"otf vertical 850 1903 Dim. Lumber 1500 Dim. Lumber May require pre-drilling; consult iniui marrufaclurer. #14 SH Orange Nut Driver Pait# 8273910 25 125 25 125 <~ C(PUS APPROVED LISTED PIPEHWER ALSO USM AS OMIT MD CABLE KAYZRIkRE AM LISTED AS ANCIM FOR LUMINAFRE LI 'Vu WOOD - Pipe Hanger Approvals W, VI 8007957 GST 0 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" - 8008957 GST2O 3/8" VeIl/cal V 2-1/2" 850 ,. V 1-1/2" 4" 1475 1-1/2' 8068925 GST 20-SS 318" Vertical 2-1/2" 850 1-1/2' 8010957 GST3O 3/8" Vertical 4' 1500 1-1I2' 4" 1475 1-1/2" 8009925 GST2S-380 318V Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8" Horizontal 3-1/2"- 4"" 1500 1-112" 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3""" 1050 1-112' 8073925 SWG 20-SS 3/8", Horizontal 2-1/2" V 850 - 1-1/2' 8139957 SH-GST 20 3/8" 17° Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" 8141957 SH-GST 30 3/8" 17° Ankle off Vertical 4' 1500 . 1-1/2 4" 1475 1-1/2" STEEL - Pipe Hanger Approvals I Rod Mount UL ax 8038957 VDTR1 V '3/8" Vertical 1500 V V 035" 4" - 1475 '105' 8037957 OSIR 1-1/2 3/8" Vertical 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical V 4" - 1500 V 037" 4" V 1475 .105' 8045957 DST 516 3/8' Vertical 4" 1500 .188" 4" 1475 188' 8046957 TEK5O 30 Vertical V 15,00. 250° 4". 1475 .188' 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 060" 8056957 SWDR 516 3/8" Horizontal V 1500 037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 037" 4" 1475 .060" 8137957 SH-DSTR1 3/8" 17"Angleoff Vertical 4° 1500 .035" V 4" 1475 .105" 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" - 8153922 XP 35 . 3/8' " Vertical - . 3-1i2" 1250', V .2: . 940 '. .029' 8294922 SXP 20 3/8" Vertical or up to 45° 2" 750 .027" 2" 635 029" 8295922 SXP3S V 3/8" Vertical orupto89" 3-112'. 1250 .060" 2" 635 .025' 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" COCR TIE - Pipe Hanger Approvals ULTffiwn jw pq 809957 CST 20 3/8" Vertical . 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 .'8150922 )(P20 3/8" ' Vertical 2-1/2' ' 850 : Pre-Pour Staictura{3000 psi:- V 8150922 XP 20 3/8" Vertical 2-10 050 Post-Pour Range II LWC S 35 PCF (lbs/It3) 77')C,Ofl*1.,._..__V_,...V-------- ...................... V ----------------_' -,-." -',.UL and I-M tests were performed in compliance with NFPA 13 Standards. 'SWG 25-380 Maximum pipe size in wood limber or joist allowed by UL is 4" Fastening requirement: 5 Sines weight of water-hOed schedule 40 pipe plus 250 pounds 'SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" "SWG 2O Maximum pipe size in wood be joist allowed byULjO3. - - V " Sarnmyti and Truss-I Hangere am registered trademarks AMM of 1W Buildex and Illinois ' - •, .. V Tool Works, Inc. . V 20067W GuIdes and 1111noiSToolWoft, Inc. REV. 0708 SSS40 -' WWWJtWbtJhIdeX,C0m 800-BUILDEX