Loading...
HomeMy WebLinkAbout6260 EL CAMINO REAL; ; AS080068; Permit12/27/24, 12:36 PM AS080068 Permit Data City of Carlsbad Sprinkler Permit 6260 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 2131100100 Lot #: 0 Reference No.:. Permit No: AS080068 Status: ISSUED Applied 4/29/2008 Approved: 4/29/2008 Issued: 4/29/2008 PC #: Inspector: Project Title: TRICITY WELLNESS BLDG. B THREE FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: MILLENNIUM FIRE PROTECTION SUITE F 101 COPPERWOOD WY OCEANSIDE, CA 760-722-2722 Owner: ECR CORPORATE CENTER LP C/O MONICA R BROWNING 5600 AVENIDA ENCINAS #100 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 195 0 195 0 about:blank THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT &uo Contractor's Material and Test Certificate for Aboveground piping PROCEDURE Upon completion of work inspection and tests shall be made by the contractors representative and witnessed by an owners representative. All defects shall be corrected and system left in service before contractors personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners and contractor. It is understood the owners representatives signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME: Tr-City Wellness Center TI 1DATE: PROPERTY ADDRESS: 6260 El,Camino Real, Carlsbad, CA PLANS ACCEPTED BY APPROVING AUTHORITIES (NAMES): Carlsbad Fire Prevention ADDRESS: INSTALLATION CONFORMS TO ACCEPTED PLANS Li YES LINO EQUIPMENT USED IS APPROVED . Li YES Li NO IF NO, EXPLAIN DEVIATIONS: INSTRUCTIONS HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? Li YES FIND IF NO, EXPLAIN HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: Li YES Li NO SYSTEM COMPONENTS INSTRUCTIONS Li YES Li NO CARE AND MAINTENANCE INSTRUCTIONS LII YES Li NO NFPA25 LIJYES LINO LOCATION OF SYSTEM SUPPLIES BUILDINGS: New Office Area MAKE MODEL YEAR OF MANUFACTURI . ORIFICE SIZE QUANTITY TEMPERATURE RATING Reliable FIFR 2010 1/2" 88 155 SPRINKLERS PIPE AND FITTINGS Type of Pipe: Sch 40, Dyna-thread Type of Fitting: Ci/Di Threaded ALARM VALVE OR FLOW INDICATOR ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST CONNECTION TYPE MAKE MODEL MIN SEC Flow Switch Potter Elec. VSR . DRY PIPE OPERATING TEST DRY VALVE Q.O.D. MODEL SERIAL NO. MAKE MODEL SEJAtNO. TIME TO TRIP THROUGH TEST CONNECTION WTER PRESS tR AIR PRESSURE TRIP POINT AIR FIRES 3 TIMffiWTER -1EACHED TEST OUTLET ALARM OPERATED PROPERLY MIN SEC PSI -f'Sl MIN SEC YES NO Without Q.O.D. With Q.OD. IXPLAIN H PNEUMATIC H ELECTRIC H HYDULIC PIPING SUPERVISED ----LJES H NO DETECTING MEDIA SUPERVISO—EYES H NO DOES VALVE OPERATE FROM THE MTALjIP AND/OR REMOTE CONTROL SADN EYES FIND DELUGE AND IS THERE AN ACCESSIBLE FACILITY IN EACH CIR R TESTING IF NO, EXPLAIN PR EACTIO N VALVES LI YES DOESH-C1CUlT OPERATE I DOES EACH C RCU MAXIMUM TIME TO MAKE MODEL tJRVISION LOSS ALARM? OPERATE VALVE RELEASE? ERATE RELEASE YES NO YES NO MI 'R— SEC. PRESSURE LOCATIO SETTING STATIC PRESSURE RESIDUAL PRESSUR E REDUCING & FLOOR MODEL WING) VALVE TEST I) I OUTLET OUTLET (PSI) FLOW (GPM) HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 pai (3.4 bars) above TEST static pressure in excess of 150 psi (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during DESCRIPTION test to prevent damage. All abovegroung piping leakage shall be stopped. PNEUMATIC: Establish 40 psi (2.7 bars) air pressure and measure drop which shall not exceed 1-1/2 psi (.01 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. IF NO, STATE REASON ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HRSJ DRY PIPING PNEUMATICALLY TESTED H YES H NO n/a EQUIPMENT OPERATES PROPERLY EYES LI NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS TEST OR STOPPING LEAKS? H YES H NO DRAIN READING OF GAGE LOCATED NEAR WATER. RESIDUAL PRESSURE WITH VALVE IN TEST TEST SUPPLY TEST CONNECTION: PSI CONNECTION OPEN WIDE _ PSI UNDERGROUND MAINS AND LEAD IN CONECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MAKE TO SPRINKLER PIPING. VERIFIED BY COPY OF THE U FORM NO. 85B EYES H NO OTHER EXPLAIN FLUSHED BY INSTALLER OF UNDER- Existing System GROUND SPRINKLER PIPING EYES H NO IF POWDER-DRIVEN FASTENERS ARE USED IN CONCRETE, HAS REP- . IF NO, EXPLAIN RESENTATIVE SAMPLE TESTING BEEN SATISFACTORILY COMPLETED? EYES H NO N/A BLANK TESTING NUMBER USED LOCATIONS NUMBER REMOVED GASKETS WELDED PIPING H YES H NO IF YES... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR-3? . EYES H NO DO YOU CERITIFY THAT THE WELDING WAS PREFORMED BY WELDERS QUALIFIED IN WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D1 0.9, LEVEL AR-3? EYES H NO DO YOU CERITIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO ENSURE THAT ALL DISCS ARE RETRIEVED. THAT OPENINGS IN PIPING ARE SMOOTH. THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? EYES H NO CUTOUTS DO YOU CERITIFY THE YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL (DISCS) CUTOUTS (DISCS) ARE RETRIEVED? EYES Effo HYDRAULIC NAME PLATE PROVIDED IF NO, EXPLAIN DATA Plate should be Existing NAMEPLATE EYES H NO DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: REMARKS NAME 01- SPRINKLER CON I RAG ION MILLENNIUM FIRE PROTECTION CORPORATION TESTS WITNESSED BY SIGNATURES FOR PROPERTY OWNER (SIGNED) TITLE DATE FOR SPRINKLER CON ACTOR (SIGNED) TITLE , DATE - - ADDITIONAL EXPLANT4ON AND NOTES