Loading...
HomeMy WebLinkAbout2647 MARMOL CT; ; AS100015; Permit1/2/25, 7:43 AM AS100015 Permit Data City of Carlsbad Sprinkler Permit Permit No: ASI000I5 Job Address: 2647 MARMOL CT Status: ISSUED Permit Type: SPRINK Applied 2/3/2010 Parcel No: 2154910200 Approved: 2/3/2010 Lot #: 0 Reference No.: Issued: 2/3/2010 PC #: Inspector: Project Title: PADILLA RESIDENCE TWO RESIDENTIAL FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: ALLWAYS FIRE PROTECTION 1451 KENT AV. ESCONDIDO, CA 760-294-5461 Owner: PADILLA JOSEPH A 2114 CRYSTAL COVE WAY SAN MARCOS CA Fees ($) Add'I Fees ($) Total ($) Balance ($) L 130 0 130 0 about:blank 1/1 - FILE COPY Aliways Fire Protection, Inc. 1451 Kent Avenue APP Escondido, California 92027 AS U8MjTTED HYDRAULIC CALCULATIONS CA ME T FOR Two Sprinklers Flowing Flat Ceiling Padilla Residence 2647 Marmol Court Carlsbad, California FILE NUMBER: Padilla Residence2.sdf DATE: JAN 28, 2010 -DESIGN DATA- Total Square Footage of Dwelling: 10,531 square feet Maximum Sprinkler Spacing 12' x 14' max. Area Calculated: Cabana Room Minimum Flow at Each Sprinkler: 15 gpm NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers FLOW REQUIRED: 35.6 gpm PRESSURE REQUIRED AT SOURCE: 51.5 psi PRESSURE AVAILABLE AT SOURCE: 90.0 psi SPRINKLER ORIFICE SIZE: 7/16" NOTE: Pipe numbers with "+" indicated length of equivalent tees on run included into pipe length, instead of fitting length. CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 50110279 HRS SYSTEMS, INC. ATLANTA, GA These plans have Ien reviewed foi apparent compliance with the oirient appi icahie codes and standards in force in the juit,dicnon. The owner or contractor may Liii lice 11111,RWA-11 in support of an application for a building peottit with Oie espress understanding that this review it no was rcheyes the owner or contrac or or their pri)lesstohtal engineer or architect for sole responsihi lttv for full compliance with said codes and standards. ttciiting the building code or forany responsihifty for ik ociencies. errors. omissions or negligence in these ilaits whether or not noted in this review. Date: Reviewer: RECOMMEND APPROVAL 0 RECOMMEND APPROVAL. AS NOTED SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 1/28/2010 C:\HASS78\FILES\PADILLA RESIDENCE2.SDF JOB TITLE: Padilla Residence - Cabana Room WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 0 PRESS. 0 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 90.0 89.9 100.0 90.0 35.6 51.5 Required pressure is 38.5 psi (43%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 35.6 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 30.6 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 321.0 - - - - 21.3 2 321.0 - - - - 21.3 3 299.0 K= 4.90 10.2 15.6 4 299.0 K= 4.90 9.4 15.0 5 299.0 - - - - 22.7 6 299.0 - - - - 21.8 A 310.0 - - - - 26.8 B 310.0 - - - - 24.4 C 310.0 - - - - 25.3 D 310.0 - - - - 26.5 E 321.0 - - - - 20.6 F 321.0 - - - - 21.3 G 321.0 - - - - 21.6 H 321.0 - - - - 21.3 I 299.0 - - - - 25.0 J 299.0 - - - - 22.7 TOR 310.0 - - - - 31.6 - - - BOR 300.0 HOSE STREAM 37.0 5.0 U 297.0 - - - - 39.7 M2 310.0 - - - - 34.7 Ml 310.0 - - - - 42.5 SOURCE 310.0 SOURCE 51.5 35.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 1/28/2010 C:\HASS78\FILES\PADILLA RESIDENCE2 .SDF JOB TITLE: Padilla Residence - Cabana Room PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 0.0 1.101 PL 1.00 FE' 0.0 1 321.0 0.0 21.3 0.0 0.0 150 FTG ET FE 0.0 H 321.0 0.0 21.3 0.0 0.000 TL 13.00 PV Pipe: 2 0.0 1.101 PL 1.00 PF 0.0 2 321.0 0.0 21.3 0.0 0.0 150 FTG ET FE 0.0 H 321.0 0.0 21.3 0.0 0.000 TL 13.00 PV Pipe: 3 0.0 1.101 PL 35.00 PF 0.0 H 321.0 0.0 21.3 0.0 0.0 150 FTG 3T2R FE 0.0 F 321.0 0.0 21.3 0.0 0.000 TL 52.00 PV Pipe: 4 -5.9 1.101 FL 26.00 PF 0.2 F 321.0 0.0 21.3 0.0 2.0 150 FTG ER FE 0.0 G 321.0 0.0 21.6 0.0 0.007 TL 34.00 PV Pipe: 5+ 5.9 1.101 FL 86.00 PF 0.1 F 321.0 0.0 21.3 0.0 2.0 150 FTG 2E PE 0.0 H 321.0 0.0 20.6 0.0 0.007 TL 100.00 PV Pipe: 6 5.9 1.101 PL 11.00 PF 0.1 H 321.0 0.0 20.6 0.0 2.0 150 FTG H PE 4.8 C 310.0 0.0 25.3 0.0 0.007 TL 18.00 PV Pipe: 7 5.9 1.101 FL 72.00 FE' 0.9 C 310.0 0.0 25.3 0.0 2.0 150 FTG 6E6R FE 0.0 B 310.0 0.0 24.4 0.0 0.007 TL 120.00 PV Pipe: 8 -24.7 1.101 FL 18.00 PF 2.4 B 310.0 0.0 24.4 0.0 8.3 150 FTG TR FE 0.0 A 310.0 0.0 26.8 0.0 0.101 TL 24.00 PV Pipe: 9 -5.9 1.101 FL 14.00 PF 0.2 G 321.0 0.0 21.6 0.0 2.0 150 FTG ET PH 4.8 D 310.0 0.0 26.5 0.0 0.007 TL 26.00 PV Pipe: 10 -5.9 1.101 FL 37.00 FE' 0.3 D 310.0 0.0 26.5 0.0 2.0 150 FTG SR FE 0.0 A 310.0 0.0 26.8 0.0 0.007 TL 42.00 PV Pipe: 11 -30.6 1.400 FL 64.00 FE' 4.1 A 310.0 0.0 26.8 0.0 6.4 150 FTG 4E6R PE 0.0 TOR 310.0 0.0 31.6 0.0 0.046 TL 102.00 PV Pipe: 12 -30.6 1.400 FL 10.00 FE' 1.1 TOR 310.0 0.0 31.6 0.0 6.4 150 FTG 2RC FE 4.3 BOR 300.0 H.S. 37.0 5.0 0.046 TL 23.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 1/28/2010 C:\HASS78\FILES\PADILLA RESIDENCE2.SDP JOB TITLE: Padilla Residence - Cabana Room PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -35.6 1.265 FL 5.00 PP 1.5 8CR 300.0 H.S. 37.0 5.0 9.1 150 FTG TG PE 1.3 U 297.0 0.0 39.7 0.0 0.101 TL 14.50 PV Pipe: 14 -35.6 2.000 PL 60.00 PP 0.6 U 297.0 0.0 39.7 0.0 3.6 150 FTG ---- PE -5.6 M2 310.0 0.0 34.7 0.0 0.011 TL 60.00 PV Pipe: 15 FIXED PRESSURE LOSS DEVICE Ml 310.0 0.0 42.5 0.0 7.8 psi, 35.6 gpm M2 310.0 0.0 34.7 0.0 Pipe: 16 35.6 0.995 PL 20.00 PF 8.9 SOURCE 310.0 SRCE 51.5 (N/A) 14.7 150 FTG TG PE 0.0 Ml 310.0 0.0 42.5 0.0 0.324 TL 27.50 PV Pipe: 17 -15.0 1.101 FL 12.00 PP 0.8 4 299.0 4.9 9.4 15.0 5.1 150 FTG ER PE 0.0 3 299.0 4.9 10.2 15.6 0.040 TL 20.00 PV Pipe: 18 -30.6 1.101 FL 58.00 PF 11.7 3 299.0 4.9 10.2 15.6 10.3 150 FTG 2E6R FE 0.0 6 299.0 0.0 21.8 0.0 0.150 TL 78.00 PV Pipe: 19 -30.6 1.101 FL 1.00 PF 0.9 6 299.0 0.0 21.8 0.0 10.3 150 FTG T FE 0.0 J 299.0 0.0 22.7 0.0 0.150 TL 6.00 PV Pipe: 20 0.0 1.101 FL 19.00 PF 0.0 5 299.0 0.0 22.7 0.0 0.0 150 FTG ET FE 0.0 J 299.0 0.0 22.7 0.0 0.000 TL 31.00 PV Pipe: 21 -30.6 1.101 FL 10.00 PP 2.2 J 299.0 0.0 22.7 0.0 10.3 150 FTG T FE 0.0 I 299.0 0.0 25.0 0.0 0.150 TL 15.00 PV Pipe: 22 -30.6 1.101 FL 16.00 PF 4.2 I 299.0 0.0 25.0 0.0 10.3 150 FTG ET FE -4.8 B 310.0 0.0 24.4 0.0 0.150 TL 28.00 PV NOTES (HASS): Calculations were performed by the HASS 8.0 computer program under license no. 50110279 granted by URS Systems, inc. 208 South Public Square Petersburg, TN 37144 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.030 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 1/28/2010 C:\HASS78\FILES\PADILLA RESIDENCE2 .SDF JOB TITLE: Padilla Residence - Cabana Room Total pressure at each node is used in balancing the system. Maximum water velocity is 14.7 ft/sec at pipe 16. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEl1 ChkViv BfyVlv GatVlv AlmChk DPVlv NPTee 2.067 5.00 10.00 3.00 11.00 6.00 1.00 10.00 10.00 10.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G V K Eli Tee 45-Eli TeeRun Coupig SwgChk GatViv AngVlv CockVi 0.995 2.00 6.00 1.50 1.50 0.50 7.50 0.00 14.00 5.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L R C S G Eli Tee 45-Eli TeeRun Coupig SwgChk GatVlv 1.265 4.50 9.00 1.50 3.00 0.50 5.50 0.00 PAGE: Z MATERIAL: CPVC-C HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L R B G C D Eli Tee 45-Eli TeeRun Btrfly Gate Check 1.101 700 5.00 1.50 1.00 0.00 1.50 7.50 0.00 1.400 8.00 6.00 2.00 1.00 0.00 1.50 11.00 0.00 100. 0 1 G 80.0 A U G E 60.0 E S 2 S U B. 40.0 E p S 20.0 —14. WATER SUPPLY ANALYSIS - 200 300 400 500 600 700 8uu Juu FLOW (GPM) Aliways Fire Protection, Inc. 1451 Kent Avenue Escondido, California 92027 APP V DAss HYDRAULIC CALCULATIONS FOR PARMNT Two Sprinklers Flowing Flat Ceiling Padilla Residence 2647 Marmol Court Carlsbad, California FILE NUMBER: Padilla Residence.sdf DATE: JAN 28, 2010 -DESIGN DATA- Total Square Footage of Dwelling: 10,531 square feet Maximum Sprinkler Spacing Area Calculated: Minimum Flow at Each Sprinkler: NUMBER OF SPRINKLERS CALCULATED: FLOW REQUIRED: PRESSURE REQUIRED AT SOURCE: PRESSURE AVAILABLE AT SOURCE: SPRINKLER ORIFICE SIZE: 20' x 20' max. Cabana Room 20 gpm 2 sprinklers 45.0 gpm 79.8 psi 90.0 psi 7/16" NOTE: Pipe numbers with "+" indicated length of equivalent tees on run included into pipe length, instead of fitting length. CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE * 50110279 HRS SYSTEMS, INC. ATLANTA, Date: 2//6/ia Reviewer: RECOMMEND APPROVAL 10 RECOMMEND APPROVAL. AS NOTED These plans have heen reviewed tot apPacl coniphancc with the cullefli applicable codes and standards in trcc in the urindiction. The ownes 01 contractor nay uO tie las ci cci in .iippott or all application lot it building mu j1h the e spiecs undco.taitduig. diat this review it it,, iay relics en the owner or contractor or their pcotessiicnal engineer or itrchiieclfor sole responsibility lid till cicillpliaICC with said codes and standards. hucli.Iuiug the building code or to, any responsihitty for delicleitcies. errors. outlisslons or negligence it, ibese pfans whether or not noted in this review. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 1/28/2010 C:\HASS78\FILES\PADILLA RESIDENCE.SDF JOB TITLE: Padilla Residence - Wardrobe WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 90.0 89.9 100.0 90.0 45.0 79.8 Required pressure is 10.1 psi (11%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 45.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 40.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 321.0 K= 4.90 16.7 20.0 2 321.0 K= 4.90 16.7 20.0 3 299.0 - - - - 49.3 - - - 4 299.0 - - - - 49.3 - - - 5 299.0 - - - - 49.3 - - - 6 299.0 - - - - 49.3 - - - A 310.0 - - - - 45.5 - - - B 310.0 - - - - 44.6 C 310.0 - - - - 39.8 - - - D 310.0 - - - - 41.2 - - - E 321.0 - - - - 34.3 - - - F 321.0 - - - - 30.3 - - - G 321.0 - - - - 33.8 H 321.0 - - - - 17.5 - - - I 299.0 - - - - 49.3 - - - J 299.0 - - - - 49.3 - - - TOR 310.0 - - - - 53.3 - - - BOR 300.0 HOSE STREAM 59.4 5.0 U 297.0 - - - - 62.9 M2 310.0 - - - - 58.3 Ml 310.0 - - - - 66.1 SOURCE 310.0 SOURCE 79.8 45.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 1/28/2010 C:\HASS78\FILES\PADILLA RESIDENCE.SDF JOB TITLE: Padilla Residence - Wardrobe PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -20.0 1.101 PL 1.00 PF 0.9 1 321.0 4.9 16.7 20.0 6.7 150 FTG ST PS 0.0 H 321.0 0.0 17.5 0.0 0.068 TL 13.00 PV Pipe: 2 -20.0 1.101 PL 1.00 PF 0.9 2 321.0 4.9 16.7 20.0 6.7 150 FTG ET PE 0.0 H 321.0 0.0 17.5 0.0 0.068 TL 13.00 PV Pipe: 3 -40.0 1.101 PL 35.00 PF 12.8 H 321.0 0.0 17.5 0.0 13.5 150 FTG 3T2R PE 0.0 F 321.0 0.0 30.3 0.0 0.245 TL 52.00 PV Pipe: 4 -25.0 1.101 PL 26.00 PF 3.5 F 321.0 0.0 30.3 0.0 8.4 150 FTG ER PE 0.0 G 321.0 0.0 33.8 0.0 0.103 TL 34.00 PV Pipe: 5+ -15.0 1.101 PL 86.00 PF 4.0 F 321.0 0.0 30.3 0.0 5.1 150 FTG 2E PE 0.0 S 321.0 0.0 34.3 0.0 0.040 TL 100.00 PV Pipe: 6 15.0 1.101 PL 11.00 PF 0.7 E 321.0 0.0 34.3 0.0 5.1 150 FTG E PS 4.8 C 310.0 0.0 39.8 0.0 0.040 TL 18.00 PV Pipe: 7 -15.0 1.101 PL 72.00 PF 4.8 C 310.0 0.0 39.8 0.0 5.1 150 FTG 6E6R PS 0.0 B 310.0 0.0 44.6 0.0 0.040 TL 120.00 PV Pipe: 8 -15.0 1.101 PL 18.00 PF 1.0 B 310.0 0.0 44.6 0.0 5.1 150 FTG TR PS 0.0 A 310.0 0.0 45.5 0.0 0.040 TL 24.00 PV Pipe: 9 -25.0 1.101 PL 14.00 PF 2.7 G 321.0 0.0 33.8 0.0 8.4 150 FTG ST PS 4.8 D 310.0 0.0 41.2 0.0 0.103 TL 26.00 PV Pipe: 10 -25.0 1.101 PL 37.00 PF 4.3 D 310.0 0.0 41.2 0.0 8.4 150 FTG 5R PS 0.0 A 310.0 0.0 45.5 0.0 0.103 TL 42.00 PV Pipe: 11 -40.0 1.400 PL 64.00 PF 7.8 A 310.0 0.0 45.5 0.0 8.3 150 FTG 456R PE 0.0 TOR 310.0 0.0 53.3 0.0 0.076 TL 102.00 PV Pipe: 12 -40.0 1.400 PL 10.00 PF 1.8 TOR 310.0 0.0 53.3 0.0 8.3 150 FTG 2RC PE 4.3 BOR 300.0 H.S. 59.4 5.0 0.076 TL 23.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 1/28/2010 C:\HASS78\FILES\PADILLA RESIDENCE.SDF JOB TITLE: Padilla Residence - Wardrobe PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -45.0 1.265 PL 5.00 PF 2.2 BOR 300.0 H.S. 59.4 5.0 11.5 150 FTG TG PE 1.3 U 297.0 0.0 62.9 0.0 0.155 TL 14.50 PV Pipe: 14 -45.0 2.000 PL 60.00 PF 1.0 U 297.0 0.0 62.9 0.0 4.6 150 FTG ---- PE -5.6 M2 310.0 0.0 58.3 0.0 0.017 TL 60.00 PV Pipe: 15 FIXED PRESSURE LOSS DEVICE Ml 310.0 0.0 66.1 0.0 7.8 psi, 45.0 gpm M2 310.0 0.0 58.3 0.0 Pipe: 16 45.0 0.995 PL 20.00 PF 13.7 SOURCE 310.0 SRCE 79.8 (N/A) 18.6 150 FTG TG PE 0.0 Ml 310.0 0.0 66.1 0.0 0.499 TL 27.50 PV Pipe: 17 0.0 1.101 PL 12.00 PF 0.0 4 299.0 0.0 49.3 0.0 0.0 150 FTG ER PE 0.0 3 299.0 0.0 49.3 0.0 0.000 TL 20.00 PV Pipe: 18 0.0 1.101 PL 58.00 PF 0.0 3 299.0 0.0 49.3 0.0 0.0 150 FTG 2E6R PE 0.0 6 299.0 0.0 49.3 0.0 0.000 TL 78.00 PV Pipe: 19 0.0 1.101 PL 1.00 PF 0.0 6 299.0 0.0 49.3 0.0 0.0 150 FTG T PE 0.0 J 299.0 0.0 49.3 0.0 0.000 TL 6.00 PV Pipe: 20 0.0 1.101 PL 19.00 PF 0.0 5 299.0 0.0 49.3 0.0 0.0 150 FTG ET PE 0.0 J 299.0 0.0 49.3 0.0 0.000 TL 31.00 PV Pipe: 21 0.0 1.101 PL 10.00 PF 0.0 J 299.0 0.0 49.3 0.0 0.0 150 FTG T PE 0.0 I 299.0 0.0 49.3 0.0 0.000 TL 15.00 PV Pipe: 22 0.0 1.101 PL 16.00 PF 0.0 I 299.0 0.0 49.3 0.0 0.0 150 FTG ET PE -4.8 B 310.0 0.0 44.6 0.0 0.000 TL 28.00 PV NOTES (HASS): Calculations were performed by the HASS 8.0 computer program under license no. 50110279 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.008 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 1/28/2010 C:\HASS78\FILES\PADILLA RESIDENCE.SDF JOB TITLE: Padilla Residence - Wardrobe Total pressure at each node is used in balancing the system. Maximum water velocity is 18.6 ft/sec at pipe 16. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AimChk DPVlv NPTee 2.067 5.00 10.00 3.00 11.00 6.00 1.00 10.00 10.00 10.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G V K Ell Tee 45-Eli TeeRun Couplg SwgChk GatVlv AngVlv CockVi 0.995 2.00 6.00 1.50 1.50 0.50 7.50 0.00 14.00 5.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L R C S G Eli Tee 45-Ell TeeRun Coupig SwgChk GatVlv 1.265 4.50 9.00 1.50 3.00 0.50 5.50 0.00 PAGE: Z MATERIAL: CPVC-C HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L R B G C D Eli Tee 45-Eli TeeRun Btrfly Gate Check 1.101 7.00 5.00 1.50 1.00 0.00 1.50 7.50 0.00 1.400 8.00 6.00 2.00 1.00 0.00 1.50 11.00 0.00 WATER SUPPLY ANALYSIS 200 300 400 500 600 700 800 900 1000 FLOW (GPM) 100 .0 1 G 80.02 A U G E 60.0 R E S S U R 40.0 E p S 20.0 0.0 —14.7 tqC17 Fire Suppression & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series RFII - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick Response, Extended Coverage General Description The Tyco® Series RFII, 5.6 K-factor, Extended Coverage, Light Hazard (ECLH) "Royal Flush" Concealed Pen- dent Sprinklers are decorative, 3 mm bulb-type sprinklers featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are opti- mal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants. The Series RFll sprinklers are intended for use in automatic sprinkler systems designed in accordance with standard installation rules (for example, NFPA 13). The fast-response thermal sensi- tivity rating of the Series RFll (TY3532) provides for a quick response, extend- ed coverage (QREC) rating up to a 20 ft. x 20 ft. coverage area. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separable, two-piece assembly design provides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. NOTICE The Series RFll Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. The installing contractor or sprin- kler manufacturer should be contact- ed with any questions. Sprinkler Identification Number (SIN) TY3532 JULY 2009 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 353-01-E (The listings apply only to the service conditions indicated in the Design Cri- teria section.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K= 5.6 GPM/psP'2 (80,6 LPM/bar112) Temperature Rating 155°F!68°C Sprinkler with 139°F/59°C Plate 200°F/93°C Sprinkler with 1650F/74"C Plate Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ...................Bronze Support Cup... Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Blub ......................Glass Cap.............Bronze or Copper Sealing Assembly................ Beryllium Nickel w/Teflont Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel DuPont Registered Trademark TFP26O 1/2' NPT SEALING ASSEMBLY FRAME CAP SUPPORT CUP WITH BULB ROLL FORMED THREADS - COMPRESSION SCREW GUIDE PINS (2) DEFLECTOR DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP I ASSEMBLY THREAD INTO AINER SUPPORT CUP THREAD UNTIL MOUNTING DPLES SURFACE IS FLUSH WITH CEILING LEJECTION RING SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 SERIES RFII CONCEALED SPRINKLER RESPONSE SPACING MINIMUM RATING FLOW/PRESSURE QUICK 16'x16' 26.0 GPM/21.6 PSI (4,9 m x 4,9 m) (98,4 LPM / 1,49 BAR) QUICK 18'x 18' 33.0 GPM / 34.7 PSI (5,5 m x 5,5 m) (124,9 LPM / 2,39 BAR) QUICK 20' x 20' 40.0 GPM / 51 PSI (6,1 mx 6,1 m) (151,4 LPM / 3,52 BAR) TABLE A SERIES RFII (TY3532) 1550F/680C AND 200°F/930C CONCEALED SPRINKLER HYDRAULIC DESIGN CRITERIA TFP26O Page 2 of 4 Design Criteria The Tyco® Series RFII Concealed Pendent Sprinklers (TY3532) are UL and C-UL Listed for use in light hazard occupancies, using the design criteria in Table A, in addition to the requirements specified in the current NFPA 13 for extended coverage pendent sprinklers. The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates with a factory-applied finish. NOTICE Do not use the Series RFII in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector—supported by the Guide Pins—then drops down to its operational position. The glass Bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Installation The Tyco® Series RFII must be installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C and 3/32 inch (2,4 mm) for the 200°F/93°C temperature ratings. Obtain a 1/2 inch NPT sprinkler joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can dis- tort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprin- kler by under- or over-tightening the Sprinkler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the centerline of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. TFP26O Page 3 of 4 Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench shown in Figure 3. Apply the RFII Sprinkler Wrench to the Sprinkler as shown in the figure. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent dam- age to the Deflector and Frame Arms when installing or finishing the ceiling. You can also use it to locate the center of the clearance hole by gently push- ing the ceiling material up against the center point of the Protective Cap. L'(.)ttiI As long as the Protective Cap remains in place, the system is considered "Out of Service" Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate/Re- tainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is dam- aged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. Screw on the Cover Plate/Re- tainer Assembly until its flange makes contact with the ceiling. Do not con- tinue to screw on the Cover Plate/Re- tainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Re- tainer Assembly with the Support Cup or you cannot engage the Cover Plate/ Retainer Assembly sufficiently to con- tact the ceiling, you must reposition the Sprinkler Fitting. TFP26O Page 4 of 4 Care and Maintenance The Tycow Series RFII must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper oper- ation of the sprinkler. If the ceiling re- quires repainting after sprinkler instal- lation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Replace sprinklers that are leaking or exhibiting visible signs of corrosion. Never repaint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint fac- tory-painted Cover Plates. If neces- sary, replace them with factory-paint- ed units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of a fire. Replace modified or over-heated sprinklers. Exercise care to avoid damage to the sprinklers before, during, and after installation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to the Installation Section. If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. Responsibility lies with the owner for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national code. Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of prod- ucts or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incom- plete information supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: TY3532, (temperature rating, listed below) Series RFII Concealed Pendent Sprinkler, P/N (specify). 155°F/68°C 200°FI93C TY3532 51-794-1-155 51-794-1-200 Separately Ordered Cover Plate! Retainer Assembly Specify: (temperature rating, listed below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139F/59°C(a) 165FI740C (b) Brass..........56-792-1-135 56-792-1-165 Chrome........56-792-9-135 56-792-9-165 Signal White (RAL 9003) 56-792-4-135 56-792-4-165 Grey White (RAL 9002) 56-792-0-135 56-792-0-165 Pure White (c) (RAL 9010) 56-792-3-135 56-792-3-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F/68°C sprinklers. For use with 200F/93°C Sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. @2008-2009 TYCO FIRE SUPPRESSION & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446