HomeMy WebLinkAbout1822 MARRON RD; ; AS130196; Permit1/2/25, 7:41 AM AS 130196 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS130196 Job Address: 1822 MARRON RD Status: APPROVED Permit Type: SPRINK Applied 11/5/2013 Parcel No: 1563011600 Approved: 12/9/2013 Lot #: 0 Reference No.: Issued: 12/9/2013 PC #: Inspector: Project Title: SOLA SALON STUDIOS INSTALL NEW FIRE SPRINKLERS AT EXISTING NON SPRINKLER 6,551 SF RETAIL BLDG REPLACE EXISTING 2 1/2" FIRE SPRINKLER RISER THAT SUPPLIES ADJACENT RETAIL STORE WITH NEW 4" RISER WITH A BUTTERFLY VALVE. THE ADJACENT OCCUPANCY IS 'TUESDAY MORNING' RETAIL STORE OCCUPANCY GRP M. NO RATING REQUIRED BETWEEN GROUP M AND GROUP B OCCUPANCIES. WESTERN FIRE TO RUN A4' MAIN 177'-6" + OR - OUTSIDE ALONG ADJACENT BLDG. Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON P0 WAY CA 858-513-4949 Owner: P K I NORTH COUNTY PLAZA L P C/0 KIMCO REALTY CORP 3333 NEW HYDE PARK RD #100 NEW HYDE PARK NY Fees ($) Add'l Fees ($) Total ($) Balance ($) 268 0 268 0 about:blank 1/1 I I Western Fire Protection Inc. I Sola Salon Studios Western Job # TIC- 1107 EQUIPMENT SUBMITTAL Ths 2huis ia\ hcci ewed ni. ippafeIi ciiIiipIitiC niiidtid' ii liic curiiit appIiahlC cndiS iiid iiay ilie owiii ir CutiCli 0(11 or biiiiihii iIi R\ ICW ii U)It II di) )1) (I!i iil ig iii! dii os en peril))t \1th he CPiC iii Ow oiiC( iii• CillifI11()i 11)11 ¼ olD rehC\C pro1eSsi0i1 eiioji(CCI or aichiect ii oic epiisihiD aud 511ltrds. 101 lull comi 11CC with said codes Re\C0'C/ RI-COMM APPROVAl 0 RECOMMEND APPR(\'-\L AS NOTEI) AS130196 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 I I I I U I I I I I I I I I I I I I I I I I I SECTION DESCRIPTION PRODUCTS 1. SPRINKLER HEADS TYCO ECOH EC-1 I & EC-I4 TYCO SERIES RFII - 5.6 K-factor TYCO TY-FRB 2. PIPING, FITTINGS & MECHANICAL COUPLINGS ALLIED DYNA-FLOW ALLIED DYNA-THREAD V1CTAULIC FIRELOCK GROOVED FITTINGS V1CTAULIC FIRELOCK GROOVED COUPLINGS #005H (2'-4') V1CTAULIC FLEX COUPLING #77 3. PIPE HANGERS & SUPPORTS TOLCO FIR. 25 SURGE RESTRAINER THREADED ROD - COOPER B-LINE FIG. 200 TRIMLINE ADJUSTABLE BAND HANGER SIDEWINDER FOR WOOD - HORIZONTAL APPLICATION FIG. 4L COOPER B-LINE FIG. 980- UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT FIG. 1001 SWAY BRACE ATTACHMENT 4. VALVES, DEVICES, & MISCELLANEOUS AGF TEST AN DRAIN V1CTAULIC FIRELOCK BUTTERFLY VALVE FOR REFERENCE ONLY A. FEBCO SERIES 800 DETECTOR CHECK *MATERIALS MAY BE SUBSTITUTED WITH LISTED EQUAL DUE TO PRODUCT AVAILABILITY I I Ii 800-381-9312 Technical Services +1-401-781-8220 www.tyco-fire.com I General Description The TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules (for example, NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers used in ordinary hazard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-il and EC-14 Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific appli- cation listing for use under concrete tees. The Series EC-11 and EC-14 Extended Coverage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprin- klers. These tests have shown that the protection provided is equal to or more effective than standard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers passed standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity should be consid- ered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series EC-11 and EC-14 Extended Coverage Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any author- ities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. FEBRUARY 2012 "11 "•' ,• L1 - -- a--- -'.-,.----, LkL Sprinkler Identification Numbers (SINs) 1Y5137 - Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent,14.0K TY5137 is a redesignation for C5137, G1894, and S2510. TY5237 is a redesignation for C5237, G1893, and S2511. TY6137 is a redesignation for 06137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. TFP22O I [1] I Series EC-11 & EC-14 - 112 and 140 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Recessed Pendent Sprinklers WRENCH FLAT TFP22O Page 2 of 8 1- Frame 2-Button 3-Sealing Assembly 4-Bulb 5-Compression Screw 6-Deflector * Temperature rating is indicated on deflector ** Pipe thread connections per ISO 7/1 can be provided on special request. 2-7/16° (61,9 mm) UPRIGHT & PENDENT ~_l 1/2 (12,7 mm) J NOMINAL MAKE-IN UPRIGHT 3/4° NPT ** ESCUTCHEON PLATE .,FATINr RI lRFAflP ly 6* CROSS PENDENT SECTION FIGURE 1 SERIES EC- 11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K-FACTOR UPRIGHT (TY6137) AND PENDENT (TY6237) - ASSEMBLY - Hazard Type Temperature Bulb Liquid Sprinkler Finish (See Note 5) Natural I Chrome I White I Lead Brass Plated Polyester Coated Upright K=11.2 (TY5137) 135°F (57°C) Orange 1,2,3**,4 155°F (68°C) Red 175°F (79°C) Yellow Light Pendent Refer to Table B for K11.2 (TY5237) K=14.0 (TY6237) 1, 2, 4 1, 2, 4 200°F (93°C) Green 286°F (141°C) UL and C-UL Blue Recessed Pendent K=11.2 (TY5237) K14.0 (TY6237) With Style 30 Escutcheon 135°F (57°C) Orange 1, 2, 3,4 1, 2, 4 N/A Sensitivity Rating Refer to Table C for FM Sensitivity Rating 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Ordinary Upright K11.2 (1Y5137) K=14.0 (TY6137) Pendent 135°F (57°C) Orange 1, 2, 3, 4 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Refer to Table B for UL and CUL Sensitivity Rating Refer to Table C for FM Sensitivity Rating K11.2 (TY5237) K=14.0 (TY6237) 1, 2, 4 286°F (141°C) Blue Recessed Pendent K11.2 (TY5237) K14.0 (TY6237) With Style 40 (57°C) __ 135°F Orange 1, 2, 4 N/A 155°F (68°C) Red 175°F (79°C) Yellow Escutcheon 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc. (UL) 5. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Cor- Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) rosion Resistant Sprinklers Approved by Factory Mutual Research Corporation (FM) Frame and Deflector only. Listings and approvals apply to color Approved by the City of New York under MEA 177-03- E (Special Order) Pendent Only N/A: Not Available TABLE A - LABORATORY LISTINGS AND APPROVALS - TFP22O Page 3 of 8 Light Hazard Ordinary Hazard Area Style 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) (57°C) (68°C) (79°C) (93°C) (141°C) Upright or Pendent - - - - - OR OR OR OR SR 14x14 Style 30 Recessed - - - - - OR OR OR OR N/A Style 40 Recessed - - - - - OR OR OR OR N/A Upright or Pendent OR* OR° OR° OR* OR* SR SR SR SR SR 16x16 Style 30Recessed OR° OR° OR* OR* OR* SR SR SR SR N/A Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A Upright or Pendent OR° OR' OR° OR* OR° SR SR SR SR SR 18x18 Style 30 Recessed OR° OR° OR° OR* QR° SR SR SR SR N/A Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A Upright or Pendent OR° OR° OR* SR* SR* SR SR SR SR SR 20 x 20 Style 30 Recessed OR° OR° OR° SR SR* SR SR SR SR N/A Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A OR: Quick Response SR: Standard Response N/A: Not Applicable ° Does not apply to Upright K=14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-1 1 OR EC-14 SPRINKLERS (Refer to Table D for Permitted K-Factor/Area Combinations) Light Hazard Ordinary Hazard Area Style 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) (57°C) (68°C) (79°C) (93°C) (141°C) Upright or Pendent - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A Style 40 Recessed - - - - - N/A N/A N/A N/A N/A Upright or Pendent OR' OR' N/A N/A N/A SR SR SR SR SR 16x16 Style 30 Recessed OR' OR' N/A N/A N/A N/A N/A N/A N/A N/A Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Upright or Pendent OR' OR' N/A N/A N/A SR SR SR SR SR 18x18 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Upright or Pendent OR' OR' N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable ° Does not apply to Upright K=14.0 TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-li OR EC -14 SPRINKLERS (Refer to FM Loss Prevention Data Sheet 2-8N for Permitted K-Factor/Area Combinations) I I I I I I TFP22O Page 4 of 8 Technical Data Approvals Refer to Table A for approval information on the TYCO Series EC-11 and EC-14 Sprinklers, as well as the TYCO Style 30 and Style 40 Two-Piece Recessed Escutcheons. The approvals apply to the service conditions indicated in the Design Criteria section. The TYCO Style 60 Two-Piece Flush Escutcheon (Figure 4) is UL Listed and FM Approved for use with the Series EC-11 and EC-14 Pendent Sprinklers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 GPM/p5i112 (161,3 LPM/bar1/2) K = 14.0 GPM/psi112 (201,6 LPM/bar112) Temperature Ratings 135°F (57°C) to 286°F (141°C) Finish Sprinkler: Refer to Table A. Recessed or Flush Escutcheon: White Coated, Chrome Plated, and Brass-Plated Physical Characteristics Frame ....................Bronze Button ....................Bronze Sealing Assembly . . . Beryllium Nickel w/T E F LO N Bulb.............Glass (3 mm dia.) Compression Screw .........Bronze Deflector ...................Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria The TYCO Series EC-11 and EC-14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Recessed Escutcheon is to be used for recessed installation, as applicable (Refer to Tables A, B, and C). UL and C-UL Listing Requirements The Series EC-11 and EC-14 Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all sprinklers in the design area. The Series EC-11 and EC-14 Sprinklers are permitted to be used with unobstructed or non-combus- tible obstructed ceiling construction as defined and permitted by NFPA 13. For example: - Unobstructed, combustible or non-combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). - Obstructed, non-combustible, ceiling construction with a deflector location below struc- tural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). The Series EC-11 and EC-14 Sprinklers, specifically tested and listed for non-combus- tible obstructed construction, are permitted to be used within trusses or bar joists having non-combustible web members greater than 1 inch (25.4 mm) when applying the 4 times obstruction criteria rule defined under "Obstructions to Sprinkler Discharge Pattern Development". The minimum allowable spacing, to prevent cold soldering between Series EC-11 and EC-14 Sprinklers, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. The Series EC-11 and EC-14 Sprinklers are to be installed in accordance with all other require- ments of NFPA 13 for extended coverage upright and pendent sprin- klers, For example; obstructions to sprinkler discharge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to storage, etc. UL and C-UL Specific Application Listing Requirements for Installation under Concrete Tees The Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, TY6137 and TY6237) have a UL and C-UL Specific Application Listing for use under concrete tees when installed as follows: The stems of the concrete tee construction must spaced at less than 7.5 feet (2,3 m) on center but 2-7/8 DIA. 1/2±1/8' (73,0 mm) 1/2" (12,7 mm) - (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF (57,2 mm) SPRINKLER /8" FIUING (3 mm) 1- _ I \ MOUNTING / SURFACE // \( MOUNTING CLOSURE ____________ - PLATE 1-3/8" (34,9 mm) 1-1/8(28,6mm) FIGURE 2 SERIES EC-1 I AND EC-I4 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2-INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON - 2-7/8' DIA. (73,0 mm) - 2-1/4' DIA. (57,2 mm) F-n 11, L- MOUNTING 1/8" SURFACE (3,2 mm) / CLOSURE 3/4" NPT 2-5/16" (58,7 mm) -MOUNTING 1-13/16" (46,0 mm) PLATE FACE OF SPRINKLER FITTING: 3/8' (9,5 mm) ABOVE TO 1/8' (3,2 mm) BELOW MOUNTING SURFACE ESCUTCHEON PLATE SEATING SURFACE: 1/4" (6,4 mm) ABOVE TO 1/2' (12,7 mm) BELOW MOUNTING SURFACE; 3/4" (19,1 mm) TOTAL ADJUSTMENT INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE .- IRON REDUCING SPRINKLER FITTING I TFP22O Ii Page 5 of 8 more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length exceeds 32 feet (9,8 m), non- combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Extended Coverage Sprinklers are to be installed in accordance with the applicable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occu- pancies. Information provided in the FM Loss Prevention Data Sheets relates to, but not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector-to-ceiling distance. These criteria may differ from UL and/ or NFPA criteria; therefore, the designer must review and become familiar with Factory Mutual requirements before proceeding with design. I I 2-7/8' DIA. 5/8±1/4' (73,0 mm) 3/4(19,1 mm) E (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) I FACE OF (57,2 mm) SPRINKLER 1/8 I FITTING (3,2 mm) MOUNTING I PLATE MOUNTING / SURFACE // CLOSURE 1-3/8' (34,9 mm) 7/8' (22,2 mm) FIGURE 3 SERIES EC- 11 AND EC- 14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4-INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FIGURE 4 SERIES EC- 11 AND EC-14 PENDENT SPRINKLER ASSEMBLY WITH 3/4-INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON TFP22O Page 6 of 8 Installation The TYCO Series EC-11 and EC-14 Sprinklers must be installed in accor- dance with the following instructions: NOTICE Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A 3/4 inch NPT sprinkler joint should be obtained with a minimum-to-maximum torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mounting surface. Pendent sprin- klers must be installed in the pendent position, and upright sprinklers must be installed in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate (or other escutcheon, as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten upright or pendent sprinklers using only the W-Type 3 (End A) Sprinkler Wrench. When installing the pendent sprinkler with Style 30, 40, or 60 Escutcheon, wrench tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. The wrench recess of the applicable sprin- kler wrench (Ref. Figure 5 and 6) is to be applied to the sprinkler wrench flats (Ref. Figure 1). Care and Maintenance The TYCO Series EC-11 and EC-14 Sprinklers must be maintained and serviced in accordance with the following instructions: NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Modified sprinklers must be replaced. Also sprinklers must be replaced that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like; are leaking or exhibiting visible signs of corrosion; were exposed to corrosive products of combustion but have not operated, if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush; or have a cracked Bulb or have lost liquid from the Bulb. Refer to the Installation section in this data sheet. Frequent visual inspections are recom- mended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. 'FITTING SIDE' TOWARDS SPRINKLER FITTING / WRENCH RECESS (END "A") FIGURE 5 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS - - 1 \ r-I-o WRENCH HEX FIGURE 6 W- TYPE 22 RECESSED SPRINKLER WRENCH The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards recognized by the Approval agency (for example, NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFP22O Page 7 of 8 Description Area Light Hazard 0.10 GPM/ft2 Group I Ordinary Hazard 0.15 GPM/ft2 Group II Ordinary Hazard 0.20 GPM/ft2 GPM PSI GPM PSI GPM PSI 14x14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 TY5137 (K=11.2) Upright 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14 x 14 - - 30 7.2 39 12.1 TY5237 16 x 16 30 7.2 39 12.1 51 20.7 (K=11.2) Pendent 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14x14 N/A N/A - - - - TY6137 16x16 N/A 39 7.8 51 13.3 (K=14.0) Upright 18x18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 14x14 - - - - - - TY6237 16 x 16 37 7.0 39 7.8 51 13.3 (K=14.0) Pendent 18x18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 psi = 0.06895 bar 1 ft.2 =0.093 m2 1 GPM = 3.785 LPM 1 GPM/ft2 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-Il AND EC-14 SPRINKLERS TFP22O Page 8 of 8 P/N 51 - XXX- X- XXX Sprinkler Temperature Rating Finish 1 1 Natural Brass 135 135°F (57°C) 4 White Polyester 155 155°F (68°C) 7 Lead Coated 175 175°F (79°C) 9 Chrome-Plated 200 200°F (93°C) 286 286°F (141°C) TABLE E PART NUMBERS FOR SERIES EC-11 AND EC-14 SPRINKLERS F_ SIN 893 11.2K Pendent TY5237 894 11.2K Upright TY5137 895 14.0K Pendant TY6237 896 14.0K Upright TY6137 Limited Warranty Products manufactured by Tyco Fire Protection Products (TFPP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFPP. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with TFPP or for products and components which have been subject to misuse, improper instal- lation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with appli- cable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFPP to be defective shall be either repaired or replaced, at TFPP's sole option. TFPP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFPP shall not be respon- sible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFPP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFPP was informed about the possi- bility of such damages, and in no event shall TFPP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a partic- ular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name, description, and P/N. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections Specify (SIN), (K-Factor), (temperature rating), (Pendent or Upright) Extended Coverage Sprinkler with (finish), P/N. Refer to Table E Recessed Escutcheon, Two-Piece Specify Style (30 or 40) Two-Piece Recessed Escutcheon with (material or finish), P/N. Refer to Technical Data Sheet TFP770. Flush Escutcheon, Two-Piece Specify Style 60 Two-Piece Flush Escutcheon with (finish), P/N (specify). Refer to Technical Data Sheet TFP778. Sprinkler Wrenches Specify W-Type 3 Sprinkler Wrench, P/N 56-895-1-001. Specify W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001. Copyright © 2007, 2012 Tyco Fire Protection Products. All rights reserved. two TEFLON is trademark of The DuPont Corporation. Worldwide www.tyco-fire.com Contacts I Series RFII - 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1!2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. L.Jt(Ii The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. MARCH 2013 1Y3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a!10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a!9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM!psi112 (80,6 LPM!bar112) Adjustment 1!2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFPI8I SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO U RETAINER SUPPORT H WITH THREAD CUP UNTIL 0 0 'k- DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING / SOLDER ' '-. COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY 1/2 NPT FRAME SUPPOR CUP WIT[ ROLL FORIV THREADS GUIDE PINS (2) DEFLECTOR II II EALING SEMBLY CAP BULB PRESSION CREW LECTOR ROPPED POSITION) TFPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ TEFLON Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. CM Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION C SPRINKLER SUPPORT CUP ASSEMBLY 1/2(12,7mm) THREADED SSS iI D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE I I I I I I I - f-- = V 3/16' to 11/16' MANUFACTURER DEFLECTOR COVER PLATE (4,6 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY COVER PLATE PROFILE DEPTH DIMENSION B 3-1/4 inches (82,6 mm) 3/16 inches (4,8 mm) COVER PLATE DIAMETER DIMENSION A 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS I TFPI8I I Page 3 of 4 Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate! Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFPI8I Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP / CEILING —\ SEAL BEVEL AS 1 COVER \ SHOWN PLATE RETAINER ASSEMBLY S \S AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, "Royal Flush II" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C) 200°F (93°C) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .. 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) ... 56-792-3-135 56-792-3-165 Signal White (RAL9003) . . .. 56-792-4-135 56-792-4-165 Jet Black (RAL9005) . . . . 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tuco TEFLON is trademark of The DuPont Corporation. spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2" NPT TY1231: Pendent 2.8K, 1/2" NPT TY2131: Upright 4.2K, 1/7' NPT TY2231: Pendent 4.2K, 1/2" NPT TY3131: Upright 5.6K, 1/2" NPT 1Y3231: Pendent 5.6K, 1/2" NPT TY4131: Upright 8.0K, 3/4' NPT TY4231: Pendent 8.0K, 3/4' NPT TY4831: Upright* 8.0K, 1/7' NPT 1Y4931: Pendent* 8.0K, 1/2" NPT I I 1 Worldwide Contacts I Series TY-FRB - 2.8, 42, 5.6, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprin- klers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. I Page I of 10 'Eastern Hemisphere Sales Only MARCH 2013 TFPI7I 2-1/4 (57,2 mm) 1-9/16 (39,7 mm) 3 STYLE 10 or 20 RECESSED ESCUTCHEON RECESSED PENDENT 2-7/8' (73,0 mm) DIA. CROSS SECTION TFPI7I Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector, special request. PLATE SEATING SURFACE 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing 7/16 (11,1 mm) NOMINAL MAKE-IN 16 M (55,6 mm) 2-3/ 1/2 NPT** WRENCH FLATS UPRIGHT PENDENT FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYI131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector, special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* I- 1( 7/16' 11,1 mm) NOMINAL MAK E- IN2-3/16' (55,6 mm) 1/2' NPT** f WRENCH FLATS UPRIGHT PENDENT STYLE 10 or 20 H- 2-7/8" (73,0 mm) DIA. —H RECESSED ESCUTCHEON RECESSED PENDENT rj 2-3/16' (55,6 mm) 1-1/2' (38,1 mm) CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT ('TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8' (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION 2-7/8' (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 3 of 10 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE I 7/16' _ (11,1 mm) /T(55,6mm) 3/16' NOMINAL 2-3/16" MAKE-IN 1-1/2' (38,1 mm) - (55,6mm) A / 1/2' NPT** T WRENCH FLATS STYLE 10 or 20 RECESSED ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* UPRIGHT PENDENT FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT 'TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector, special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE NNOMINAL 1/2 (12,7 mm) 2-1/4' (58,7 mm) 1-9/16' MAKE-IN ______ 2-5/16" (39,7 mm) wo (57,2 mm) 3/4" NPT** t WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON FIGURE 4 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY4131) AND PENDENT (Y4231) SPRINKLERS - 8.0 K-FACTOR, 3/4 INCH NPT TFPI7I Page 4 of 10 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw __1 3 - Sealing 6 - Deflector * UNOMINAL 7/16 _________ 2-1/4 Assembly 4 - Bulb (11,1 mm)(57,2 mm) : * Temperature rating is MAKE-IN 1-9/16 indicated on Deflector. 23/16 (39,7 mm)(55,6mm) _______5 ** Pipe thread connections ____________ per ISO 7-1 can be 6 * provided on special 1/2' NPT** f WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 G PM/psi112 (40,3 LPM/barl/2) K=4.2 GPM/ps11'2 (60,5 LPM/barl/2) K=5.6 GPM/psi1'2 (80,6 LPM/barl/2) K=8.0 GPM/psi112 (115,2 LPM/barl/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Beryllium Nickel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector...........Copper/Bronze Bushing (K=2.8) ...........Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprinklers are intended for fire protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklersmust be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint shold be obtained by applying a min- imum to maximum torque of 7 to 14 ft.l-bs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With refer- ence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprin- kler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED SIGNAL*** J WHITE 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue RECESSED PENDENT (TY1231)° Figure 6 135°F (57°C) Orange 1,2, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY1231)** Figure 7 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F (57°C) Orange 1,2 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY2231)* Figure 8 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY2231)** Figure 9 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** WHITE LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 3, 5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (1Y3231)* Figure 10 135°F (57°C) Orange 1, 2, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PEN DENT (TY3231)** Figure 11 135°F (57°C) Orange 1, 2, 3, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)* Figure 12 135°F (57°C) Orange 1, 2, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)** Figure 13 135°F (57°C) Orange 1, 2, 3, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F (57°C) Orange 1, 2, 4, 5, 6 Blue 1, 2, 5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS I TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME SIGNAL LEAD FACTOR BRASS PLATED WHITE COATED PENDENT (TY1231) and 2.8 UPRIGHT (TYI131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) PENDENT (TY3231) N/A PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI ( 12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and UPRIGHT (TY4831) 175 PSI (12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) Only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. I I Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to TABLE C MAXIMUM WORKING PRESSURE corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. TFPI7I Page 8 of 10 2-7/8 DIA. 5/8±1/4 (73,0 mm) 3/4' (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4' (6,4 mm) / FACE OF - (57,2 mm) I SPRINKLER MOUNTING PLATE FITTING (3,2 mm) \% SURFACE MOUNTING CLOSURE SERIES 1-5/16" mm) TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE FITTING 1/8" / (3,2 mm) \%_ U MOUNTING I SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE 1Y-FRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7+3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I /FACE OF T (57,2 mm) MOUNTING FITTING L1(3,22 /8" mm) P77 7/ % SPRINKL PLATE SURFACE MOUNTING CLOSURE SERIES 1-5/16" mm) - TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) - 1/2" (12,7 mm) (12,7+3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FITTING /FACE OF MOUNTING (57,2 mm) PLATE / 1/8" (3,2 mm) SPRINKLER MOUNTING I SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE 1YFRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I Page 9 of 10 2-7/8' DIA. 5/8±1/4 (73,0 mm) 3/4' (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. I 1/4' (6,4 / FACE OF (57,2 mm) MOUNTING SPRINKLER t PLATE FITTING 1/8 (3,2 mm) \4 MOUNTING SURFACE SE RIES 1-1/4(31,8mm) CLOSURE TYFRB 3/4' (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8 DIA. 5/8±1/4' - (73,0 mm) - 3/4 (19,1 mm) / (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) (57,2 mm) FACE OF MOUNTING SPRINKLER L.. 7.) - PLATE FITTING )_ I I 1/8' / I (3,2 mm) MOUNTING / SURFAC>// - CLOSURE SERIES 1-5/16" (33,3 mm) 1Y-FRB 13/16' (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT - 2-7/8' DIA. 1/2±1/8' (73,0 mm) 1/2' (12,7 mm) (12,7±3,2 mm) 2-1/4' DIA. 1/4' (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8 (3,2 mm) \ MOUNTING SURFACE SERIES 1-1/4 (31,8 mm) CLOSURE TYFRB 1' (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. 1/2±1/8' (73,0 mm) I 1/2' (12,7 mm) I (12,7±3,2 mm) 2-1/4' DIA. I 1/4 (6,4 mm) / FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE I FITTING MOUNTING SURFACE CLOSURE SERIES 1-5/16 (33,3 mm) TYFRB 1-1/16 (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT I I F] WRENCH RECESS (END 'A' USED FOR 1/2' NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4' NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W- TYPE 7 RECESSED SPRINKLER WRENCH -I- 1 NATURAL BRASS PURE WHITE (RAL9O1O)° SIGNAL WHITE (RAL9003) 7 LEAD COATED 9 CHROME PLATED X JET BLACK (RAL9005)°° * Eastern Hemisphere sales Only. ** Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires lead time to manufacture. TFPI7I Page 10 of 10 P/N 57- XXX- X- XXX I I II SIN SPRINKLER I I I FINISH 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) 1Y2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4°NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831' 361 8.0K PENDENT (1/2"NPT) TY4931° TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F(68°C) 175 175°F(79°C) r200 200°F (93°C) 286 286°F (141°C) TABLED SERIES TV-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) tempera- ture rating, (specify) finish or coating, P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Refer to Technical Data Sheet TFP770. GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tqcc, TEFLON is trademark of The DuPont Corporation. NIPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/m lbs/Ft; kg/rn Unthreaded 1.191 0.830 1.31 2.41 25 30.3 1.2 - - 1.95 - 1¼" 1.536 1.059 1.87 1.55 ' 32 39.0 1.6 -. 2.78 - 1½" 1.728 1.667 2.71 3.44 r40 T3.9 2.203 2.104 3.79 2.78 50 56.0 3.1 5.64 - 21/2" 2.703 2.564 5.10 1.60 65 68.7 3.8 7.59 - 3.314 3.387 7.18 1.48 75 84.2 5.0 10.69 - 4.310 4.473 10.86 1.00 100 109.5 6.7 16.16 - High Strength Steel Pipe Dyna-Flowl pipe is the original" high-strength lightwall sprinkler pipe. Dyna-Flow has I outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. I Additional Benefits Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft D.C.) per NFPA. Available in standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end I preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. Superior Hydraulics With an inside diameter of up to 11% larger than Schedule 40 I and up to 7% larger than SchedulelO, Dyna-Flow, pipe hydraulics are exceptional. Larger l,D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." I Coatings & Fabrication Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable, exterior black coating is paintable and acts as an excellent primer that is resistant to weathering and I U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No special process or equipment is needed for fabrication and installation. American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Flow, pipe is manufactured to meet ASTMA 795, Type E Grade A, and are in compliance with NFPA-13 and NFPA-14, All sizes of Dyna Flow are UL Listed, FM Approved and ULC Listed. Dyna-Flow is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, pre-action and deluge systems. It is FM Approved for roll grooved, plain-ended, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna-Flow is now available "hot-dip" galvanized* and has been specifically approved by FM for dry systems uses. APPROVEQ * Must be ordered in 10 bundle increments. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com 9 allied • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT' Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 02008-10 Tyco mt., All Rights Reserved, STP-S2-4-NON-1004 *; ,:,;: :. 0 : 4~ ":Y . T. 3TiJ l - Full Line Sch-40 Replacement DynaThreadn sprinkler pipe represents an engineering advancement for the sprinkler I pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to I 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to I make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-f it applications. Corrosion Resistance Ratio (CRR) is I a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated I wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Dyna-Thread is approved for standard hanger spacing (15 ft. D.C.), can be used I as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. I American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Thread pipe is manufactured to meet: I ASTM A 135, Type E Grade A, and is in compliance with NFPA-1 3. All sizes of Dyna- Thread are rated at 300 psi working pressure. Dyna-Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Dyna-Thread can be "hot-dip" galvanized* to meet FM requirement for dry systems. I Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). NPS Nominal ID, Wt. Wt. (H20 Filled) CRR CRR In; mm In; mm Lbs/Ft; kg/rn LbsIFt kg/rn unthreaded Threaded 1.080 1.330 1,75 11.39 1.00 25 27.4 2.0 2.60 - - - 11/4 1.408 1.870 2.54 9.50 1.00 32 35.8 1 2.8 3.78 - - 11/2 1.639 2.290 3.22 9.14 1.00 40 41.6 3.4 4.79 - - 2.104 3.050 4.57 8.41 ).00 50 53.4 4.5 -- 6.80 - -- APPROVED I I Project: Engineer: I Locations: (7'~alhed TUBE & CONDUIT* Sprinkler Contractor: Specification Reference: Comments: Customer Service (800) 882-5543 Fax: (800) 659-7730 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 * Must be ordered in 10 bundle increments. Date: System Type: www.alliedtube-sprinkler.com 600 Dean Sievers Place Morrisville, PA 19067 ©2009-1O Tyco 1st., All Rights Reserved, STP-S3-4-NON-1003 FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock EZ® Style 009H couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Red Enamel in EMEA-l. Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Location Date Approved Date www.vjctaulic.com vicTAuLic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVJ U U I Para JtauIicr 10.031 IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.03 to E to W-. b NO. 003 NO. 002 NO. 006 DIMENSIONS I. C to E to E NO. 001 T ~71 90 Elbow SJ? 45* Elbow 11 Straight Tee 1 1/4 32 1.660 42.4 - - - - - 08 21 1 1 03 01 1½ 40 .900 48.3 - - - - - - - - - - - 0.82 21 04 02 2 50 • 2.375 60.3 2.75 70 1.7 0.8 2.00 51 1.8 08 2.75 70 2.4 1.1 0.88 22 06 03 21/2 2.875 3.00 3.1 2.25 2.2 300 3.6 088 22 1 1.0 05 76.1 mm 30 76.1 300 76 1.5 0225 24 57 11 - ' I - - 3 80 3.500 88.9 3.38 86 4.0 1.8 2.50 64 3 14 338 86 53 24 088 22 1.2 0.5 108 - 4,250 108.0 - I 4.00 102 5.7 2.6 3.00 76 1 5 . 4.00 2.0 ___ 75 4 100 4.500 114.3 4.00 102 6.7 3.0 3.00 76 5.6 25 4.00 102 87 3.9 I 1.00 25 2.4 1.1 5 125 5.563 141.3 4.88 : 124 12.6 5.7 3.25 83 83 38 4.88 124 I 157 71 1,00 25 4.1 1.9 15 9mm 6.250 158.8 5.50 140 12.6 5.7 3.50 89 9.2 4.2 5.50 140 179 80 - 6 150 6.625 168.3 5.50 140 , 18.3 8.3 3.50 89 11.7 5.3 550 140 227 10.3 1.00 25 5.9 2.7 8 200 8.625 219,1 6,81 173 25.5 11.6 4,25 108 1 20.4 9.3 6.94 176 387 176 113 29 12.7 5.8 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.032 JtauIic REVJ ___ 1= Frictional Equivalent Feetimeters IL Resistance of Straight Pipe f 1¼ 1.660 - - - - 32 42.4 - - - - 1½ 1.900 40 - 48.3 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2½ 2,875 4.3 2.2 10.8 4,3 65 73,0 1.3 0.7 3.3 1.3 761 mm 3.000 4.5 2.3 11.0 4.5 76.1 , 1.4 0.7 3.4 1.4 3 3.500 1 5.0 2.6 13,0 5.0 80 - 88.9 1.5 0.8 4.0 1.5 108mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2,1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159mm 6.250 9.4 4.9 25.0 9.6 158.8 I 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 The flow data listed is based upon the pressure drop of Schedule 40 pipe. FLOW DATA I I I I I I PS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings I I I www.victaulic.com vICTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV 'ftaulicr 10,033 GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009V/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.03 1539 REV J UPDATED 8/2011 ictauIic vicTAuLic IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 STYLE 005H WITH VICPLUSTM GASKET SYSTEM FireLock Style 005H rigid coupling has a unique, patented angle-pad design which allows the t~ I 0(j housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This PATENTED reduces components to handle during assembly. Style 005H FireLock coupling are designed and recommended for use ONLY on fire —ket System protection systems. VicPlusTM Gasket System: Victaulic offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The Vic-Plus System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. Exaggerated for clarity LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure - U QD I aim _ U 14-2' 300 - _ N/A N/A Related L LL 175 175 EL MT 1 1/4 -21 300 N/A I N/A 11/4 -I 350 1 3.50 350 ET 1¼-21 300 1 N/A 1 N/A STE 154-4 1 N/A N/A 300 10,40 5-8 300 300 1 300 EZ N/A 300 Steady li/ N/A 300 BLT 154-2300 N -4N/A I N 0 A N OF 1¼-4 300 300 1 300 GAL-7 1 ¼_2i 300 N/A N/A WLS 154-2' 300 300 1 FJ/,4 DI 154-21 300 300 1 N/A MLT 154-2' 300 N/A N/A XL 300 [F i:Tt'@:N/ 175 MF T±'o N/A 300 I JOB/OWNER System No. Location FM approved for service in 1 ½ - 4" pipe. UL Listed for service up to 4" pipe only. @ UL Listed for service up 103" only. CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved Date Para I I www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV 4tauiici 10.021 PS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 Firel-ockO Rigid Coupling STYLE 005H WITH VIC-PLUSTM GASKET SYSTEM • 1.660 7S& 350 755 Sep. U MR 1 005 t No - SizeDinnersions L 2- __Approx. LL 275 450 mm 1I L11 188 Wgt. Each IR 1.2 1 1/4 32 42.4 2413 3370 1.2 /sv 2/a 1 70 14 1 48 0.5 1½ 1.900 350 990 005 3.00 4.75 188 1,2 40 483 2413 4415 1.2 2-~x2/a 76 121 48 0.5 2 2375 350 1550 0.07 350 1 5.25 1.88 1.6 50 603 2413 ' 6900 1.7 - X 89 133 48 0.7 21/2 2,875 350 . 2270 007 4.00 5.75 88 1.9 65 730 2413 10110 7 2-~n2/r102 146 48 .09 3.000 350 ' 2475 0.07 4.13 5.75 1.88 1.9 76.1 mm 761 2413 11010 1.7 ,, sx2/r 2-3/o 105 146 48 0.9 3 3.500 . 350 1 3365 0.07 2-Isx2/r 4.63 6,13 1.88 2.1 80 889 2413 14985 1.7 118 156 48 1.0 4 4.500 350 5565 0.16 xv 2 5.75 7.25 2.13 3.1 tOO 114.3 2413 24770 4.1 - , 146 184 54 1 1.4 108.0mm 4.250 300 4255 0.16 2-Irx2/2 5.63 7.25 I 2.13 3.1 108.0 2068 18940 4.1 143 184 1 54 1,4 5 5.563 300 7290 0.16 6.88 9.00 2.13 4.5 125 141.3 2068 32445 4.1 2-/2 x 3 175 229 54 2.0 5.250 1 300 6495 0.16 ; 6.63 9.00 . 2.13 45 133.0mm 133.0 2068 28900 4,1 2-/ax 24 ,229 54 2.0 139.7 mm 5.500 300 7125 0.16 2-/ax 2 6.88 9.00 2.13 4.8 139.7 2068 31715 4.1 175 229 54 2.2 6 6.625 W010340 2 - 2 X 9,3l 0 5.0 iSO 168.3 2068 , 46020 4.1 I 203 254 1 53 2.3 159.0 met 6.250 300 9200 2- ½ x 2~ 1000 213 55 159.0 2068 40955 .1 194 54 215 165.1 mm 6.500 300 9955 0.16 1 2-/2n 3 8.15 10.00 2.13 5.5 165.1 2068 44295 1 4.1 207 254 54 2.5 8 8.625 , 300 17525 0.19 10.50 13.14 2.63 11.3 200 219.1 2068 78000 4.8 2 - 9, X 41/4 267 334 67 5.1 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure maybe increased to 1½ times the figures shown. The allowable pipe separation dimension shown is for system layout purposes only. Style 005H couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005H couplings are VdS and LPC Approved to 1613ar/235 psi. DIMENSIONS It'c!II Rated for wet and dry sprinkler systems at 350psi/2413kPa fort Va - 4732 - 100mm sizes and 300 psi /2068kPa for 41/4 - 8/108 - 200mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005H is rigid and does not accommodate expansion, contraction or angular deflection. www.victaulic.com - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02013 VICTAULIC COMPANY, ALL RIGHTS RESERVED. icta ul i c 10.022 REV 'K U'S CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005H WITH VIC-PLUSTM GASKET SYSTEM MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) Optional: Hot dipped galvanized Gasket: Grade "E" EPDM - Type A Vic-Plus Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Vic-Plus'° Gasket System, requiring no field lubrication for most installation conditions. Grade "L" Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal® Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to —40°F/--40°C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. I I I I www.victaulic.com vlclAuuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VCTAUL?C COMPANY. ALL RIGHTS RESERVED. REVK 4tauiicr 10.023 I I STYLE 005H WITH VICPLUSTM GASKET SYSTEM GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. For complete contact information, visit www.victaulic.com 10.02 1538 REV K UPDATED 0212013 iCtaUIiC VIcTAuLIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 vlcrAuuc COMPANY. ALL RIGHTS RESERVED. 10.02 I 3/4 - 12/20 - 300MM SIZES 14 - 24/350 - 600 MM SIZES STYLE 77 I Style 77 couplings are designed with cross-ribbed construction to provide a strong component for pressure piping systems. The coupling is offered in a two piece housing I design from 3/4 - 24/20 - 600mm sizes for pressures up to 1000 psi/6900 kPa. All sizes are provided with plated bolts and nuts. Galvanized and stainless steel housings are also available. Independent testing has shown the Style 77 coupling to be an effective stress relief and vibration attenuation device providing performance superior to braided steel and elastomeric arch-type connectors when used in close proximity to the source of vibration. Refer to 26.04 for vibration information. Independent testing has shown that Victaulic Style 77 flexible couplings provide exceptional functionality during and after earthquake conditions. Refer to 26.12 for further information. For 14 - 24/350 - 600mm flexible roll groove systems, Victaulic recommends Style W77 AGS couplings. For more information, request submittal publication 20.03. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel. Optional: Hot dipped galvanized and others. Coupling Gasket: (specify choice*)t Grade "E" EPDM (All other sizes) EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade '1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. NOTE: Additional gasket styles are available. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Optional: Type 316 stainless steel, Grade B-8M, Class 2. t Supplemental lubricant is recommended for services installed at or continuously operating below 0°F/-18°C. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect- Para__________ Location Date Approved I r IH www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. REVM 4tauiac 06.041 I CARBON STEEL PIPE - GROOVED COUPLINGS 06.04 Standard Flexible Coupling STYLE 77 DIMENSIONS Size _.irn m .'yiiiTiiFj 34 1.050 1,000 1 865 0-0.06 3 24' 0.72 . 2.13 4.00 1.75 1.1 20 26.7 6900 3850 0-1.6 - 60 - 4 x 2 54 1 102 44 0.5 1 1.315 1,000 1,360 0-0.06 2-43 0.57 2-~x2 2.38 4.12 1.75 1.2 25 33.4 6900 6050 0-1.6 48 105 44 0.5 11/4 1.660 1,000 2,160 0-0.06 0.45 2.65 j 5.00 1881 2.0 32 42.2 6900 9610 0-1.6 2 10 38 2-½x2½ 67 I 127 48 0.9 1½ 1.900 1,000 2,835 0-0.06 . 0.40 I 3.13 5.38 1.88 2.1 40 48.3 6900 12615 0-1.6 1 56 33 2-/:x2½ 1 79 137 48 1.0 2 2.375 1,000 4,430 - 0.06 0.32 I 3.63 5.88 1.88 2.6 50 60.3 6900 19715 0-0.06 5 0-1.6 1'- 31' 2-V x y 92 149 48 1.2 57.0mm 2.664 1,000 3955 0 -0.16 1 -34 0.33 I 2-½x2½ 3.43 5.73 1.9 3.0 57,0 6900 17592 0-1.6 27 87 146 48 1.4 2112 2.875 1,000 6,490 0-0.06 0.26 4.25 6.50 1.88 3.1 65 73.0 6900 28880 0-1.6 1 -15 , 22 2-Ax 2% 108 165 48 1.4 76.1 mm 3.000 LOUD 7,07% 0-0.06 0.26 06 2-½x2% 4.38 63 76.1 6900 22 Ill 168 98 _3.2 1.5 3 3.500 1,000 9,620 0-006 1 -2 0.22 I 5.00 1 7.13 1.88 3.7 80 88.9 6900 46810 0-1.6 1 18 2-/2x2% 127 181 48 1.7 31/2 4.000 1,000 12,565 1 0-0.06 0.19 2 1.88 i 5.6 90 101.6 6900 55915 0-1.6 16 143 210 48 j 2.5 4 4.500 1,000 15,900 0-0.13 1 - 36' 0.34 - 2 " < V 6.13 8.88 2.13 6.7 100 114.3 6900 70755 0-3.2 I 28 156 226 54 3.0 4.250 1,000 14,180 0- 0.13 0.35 6.00 8.63 2.13 11.0 1080 mm 108,0 6900 63100 0-3.2 - 29 - X . 2 16 825 152 219 54 , 5.0 5 5.563 1,000 24,300 0-0.13 0.27 2-/xx4,4 7.75 . 10.65 2,13 10.6 125 141.3 6900 108135 0-3.2 18,23 197 270 54' 4.8 133.0mm 5.250 1,000 21,635 0-0.13 , 1 -21 . 0.28 2-20x108 7.63 10.38 2.13 ' 10,0 1330 6900 96275 0-32 24 194 1 264 54 45 139.7mm 5.500 1,000 23,745 0 1 24 " 0.28 0.65 2-20x108 83 2 , 13 140 139,7 6900 10665 02 219 270 6 6.625 1,000 34,470 0-0.13 1 1 0.23 2-34x4/s 8.63 11.88 2.13 12.0 150 168.3 6900 153390 1 0-3.2 , 18 1 219 , 302 54 5.4 159.0mm 6.250 1,000 30665 2-20x108 11.50 213 132 165.1 mm 6.500 1,000 I 33,185 0 -0.13 . 1 -6 0.23 2- Ax 44 8.88 , 11.63 2,13 13.2 165.1 6900 , 147660 0- 3.2 19 226 1 295 54 6.0 Table continued on page 3. See notes on page 3. ¼ - 12/20 - 300 MM SIZES 14- 24/350 -600 MM SIZES www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 06042 4tauI iICY REVM CARBON STEEL PIPE - GROOVED COUPLINGS II.1IsIY! Standard Flexible Coupling STYLE 77 DIMENSIONS IIM I M1 Deflect.r ilMè Dimensions .j.ivi T_T T 1 LILI 85 8.625 800 46740 j 0-0.13 0.18 11.00 0-50 2 - </x 5 14.75 2.50 20.8 200 219,1 500 207995 0-3.2 279 ,jj,__ 375 63 9.4 10§ 10.750 73,280 0-0.13 L18:5000:0 0 - 40 0.14 13.63 2-1 x6 17.13 ' 263 31.1 250 273.0 326100 0-3.2 12 346 435 67 14.1 125 12.750 I 800 102,000 0-0.13 0- 34' 0.12 2-1 x6½ 15.63 1925 2.63 27.8 300 3219 I 5500 453900 0-3.2 9 397 489 67 12.6 14 * 14.000 1 300 46,180 0-0.13 0 - 31' 0.11 16.75 2-1 <3½ 20.25 3.00 39.2 350 355.6 j 2065 205500 0 - 3.2 9 425 514 76 17.8 377.0mm < 14.842 300 51,875 j 0-0.13 0. 31' 0.11 17.39 - 2-1x3½9 20.96 2.8 48.8 377.0 2065 230,845 0-3.2 442 531 71 22.1 169 16.000 300 60,320 0-0.13 0'-27' 0.10 2-1 <3½ 18.75 22.25 3.00 45.0 400 406.4 2065 268425 0-3.2 9 476 565 76 20.4 426.0mm 1< 16.772 300 66,245 0- 0.13 0 -27' 0.10 19.69 2-tx 3½ 22.92 2.92 56,7 426 2065 294,795 0-3.2 9 500 581 74 25.7 18 * 18.000 300 76,340 0-0.13 0 -24' 0.08 21.56 2- 1VsX4 25.00 3.13 64.1 450 457.2 2065 339710 0- 3.2 7 548 635 80 29.1 480.0mm .1 18.898 300 84,105 0-0.13 0.-24' 0.08 22.38 2 -1¼x4 25.86 3.04 77.2 48 2065 374,265 I 0- 3.2 7 569 655 77 35 209 20.000 300 94,000 0-0.13 0 -22' 0.08 23.63 2-1'/sX4 27.00 3.13 74.8 500 508.0 2065 1 418300 0-3.2 7 600 686 80 34.0 22 22.00 300 114,000 I 0-0.13 0.07 25.63 29.13 3.13 82.6 550 559.0 2065 507300 0 - 3.2 0. -19' 2-1</sx4 6 651 740 1 80 37.5 530.0mm 20.866 300 102,535 < 0-0.13 0'-22- 22' 0.08 2-1/ux4 24.29 27.8 3.07 91.7 530 2065 456,280 I 0-3.2 7 617 ________ 704 77 41,6 580.0mm 1 22.835 300 102,380 1 0-0.13 o- 19' 0.07 26.76 2-1¼x4 30.01 3.12 92.8 580 2065 455,591 j 0-3.2 6 680 762 79 42.2 24 * 24.000 250 113,000 1 0-0.13 0.07 27.75 31.00 3,19 89.6 600 609.6 1725 502850 0-3.2 0'-18' ' 2-158 x 4 6 705 787 81 40.7 630.0mm < 24.803 250 102,790 I 0-0.13 0 - 18' I 0.07 28.42 2-1¼x4 32.16 3.12 96.8 630 1725 457,416 0- 3.2 6 722 817 79 44 14-24 AGS See Style W77, Publication 20.03 350-600 § Couplings 8, 10, 12/200, 250, 300 mm sizes available to uS standards. Refer to Section 06.17 for details. Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING; FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by; 50% for 3/4 -3 1/2720 -90mm; 25% for 4/100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. * For 14 - 24/350 -600mm Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Request publication 20.03 for informa- tion on the Style W77 flexible AGS coupling. p CIS size product is designed with two housings and requires two bolts. 3/4 - 12/20 - 300 MM SIZES 14- 24/350 -600 MM SIZES I www.victaulic.com viciuic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VITALIC COMPANY. REV_M \4taulicr 06.043 STYLE 77 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 06.04 1469 REV M UPDATED 3/2011 x. Aic--taulic' vIcTAuLIC IS REGISTERED TRADEMARK OF viciuic COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 06.04 Fig. 25 - Surge Restrainer C®USLISTED I I I Size Range - One size fits 3/4 thru 2 pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed Qniy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4' thru 2". Patent #5,344,108 I OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786,5266 www.tolco.com 1.1II..I Fig. B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) Fig. B3205L - Threaded Rod (right & left hand threads) Size Range: i-i 6 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish 1i1[' B3205-I8 x 'L' Thread ISize /8-16 Thread TfLength ' 21/2 Standard I (63.5) ' 730 Design ' (3.25) Load 572 I (2.54) B3205-112 x 'L' 1/2"..13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-518 x 'L' /8°-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-314x 'L' I4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-718 x 1 7/811-9 31/2" (88.9) 1 4480 1 (19.93) 1 3508 1 (15.60) For larger sizes consult full line pipe hanger catalog. I I Fig. AIR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: i'-i 6 thru 11/2_6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. & Size AIR I4" x 'L' Threads Pe I 20 Recommended 240 Load ' (1.07) Approx. Wt./100 12 Ft. (5.44) AIR /8" x 'L' 16 730 (3.24) 29 (13.15) AIR 1/2" x 'L' 13 1350 (6.00) 53 (24.04) AIR I8" x 'L' 11 2160 (9.60) 89 (40.37) AIR 3/4" xi' 10 3230 (14.37) 123 (55.79) AIR I8" x '1' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line 44 Fig. 200-1 to 200-2 Fig. 200-21/2 to 200-8 t2' - Fig. 200 Fig. 200F Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) ®TDLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut I I c®uS LISTED I Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2' (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Part i 200.1/2 Pipe 1/2 (15) Rod Size 3/8"-16 , 31/8 (79.4) 2/ (66.7) 11 II (5.0) 200-/4 3/4 (20) I-16 31/8 (79.4) 21/2' (63.5) 11 (5.0) 200-1 1" (25) /8-16 3/8' (85.7) 2/8 (66.7) 12 (5.5) 200.11/4 11/4 ' (32) /8-16 33/4' (94.0) 2/8° (73.0) 13 (5.9) 200.11/2 11/2° (40) /8-16 37/8 (98.4) 2/8 (73.0) 14 (6.4) 200-2 2° (50) /8-16 41/2' (114.3) 3° (76.3) 15 (6.9) 200.21/2 21/2 ' (65) /8-16 5I8 (142.9) 41/8 (104.7) 27 (12.3) 200-3 3 (75) /8-16 5/8° (149.1) 4 (101.6) 29 (13.3) 200.31/2 31/2 (90) /8-16 7/8° (187.3) 51/4° (133.3) 34 (15.6) 200-4 4° (100) /8-16 7/8' (187.3) 5° (127.0) 35 (16.0) 200-5 5° (125) 1/2 13 91/8° (231.8) 61/4 (158.7) 66 (30.2) 200-6 6° (150) 1/2 ..13 101/8 (257.2) 6/4" (171.4) 73 (33.4) 200-8 8 (200) 1/2"13 131/8' (333.4) 8/4 (222.2) 136 1 (62.3) Fig. 200S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 000 COOPER B-Line I ZAEfflyz @ No pre-drilling required. Quick to install using the Sammy Nut Driver with an iSV cordless drill/driver. Saves time from traditional methods. Reduces installation costs, Made in the U.S.A. Not less than 2" nominal width (1-1/2") up to 3-1/2" pipe, not less than 3" (2-1/2") nominal width 4 & 5 pipe I Floor Joist Minimum 2-1/2 from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2 or , thicker nailing ott/ps renting on top of steel beams. ----- Ii I I Watch a video demonstration at = www.itwbuildex.com U 1/4" 8019957 SWG 200 1/402" 1725 (Fir) 25 125 -. 3/8 6020957 SWG 10 1/4x1" 622 (Fir) 300 25 125 I .® 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 8073925 SWG 2(-SS 114x2 1725 (Fir) 850 25 125_J I 3/8"'" 8022925 SWG 25-380 3/8x2-1/2" 2249 (Fir) 1500 25 125 #14 SW Rod L 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 .J Nut Driver Part #8114910 * May require pro-drilling; consult inlet manufacturer. YAVIWIhTfSWIVEL H y '.J;I WOOD Swivel 7v y7IITI, WOOD JOIST slvomicmav Eliminates distortion of threaded rod. - . . • Accommodates up to 3 /x 12 pitch roof. - .... • Allows 17° deflection from vertical. HANGER' eon t ,, • Saves time from traditional methods. : 14i • Reduces installation costs. :/i'! \ MAX Made in the U.S.A. lox Case )tY Qty 1903 Dim. Lumber 3/8* 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 450off vertical Dim. Lumber May require pre-drilling; consult joist manufacturer. I I Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment Size Range: 2" (50mm) through 8" (200mm) IFS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and . Canada (cUL) 2" (50mm) through 8" (200mm) pipe. J. For FM Approval information refer to page 47. Installation Instructions: Fig. 4L is the braced pipe attachment component of a longitudinal sway brace assembly. It is intended to be combined with the bracing pipe and Cooper B-Line/TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 guidelines should be followed. I To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage bracing pipe into jaw opening and tighten set bolt until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. I Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. t Rnit 2. 14-d rn, In,I,,dl 4-Way Riser Brace (plan view) Longitudinal Brace Part Pipe Size A C D Bolt Size 1/2"-13 Max. Rec. (cULuc) 2596) Load Approx. Wt./100 247 4L-2112 21/2 (65) 6/16" (163.5) 21/2 (63.5) 2/4" (69.8) 1/2"..13 2015 (8.96) 253 (114.7) 4L-3 3" (80) (177.8) 2/4" (69.8) 31/16" (77.8) 1/2"_13 2015 (8.96) 268 (121.5) 414 4' (100) 81/2 (215.9) 33/8" (85.7) 311/16" (93.7) 1/2"_13 2015 (8.96) 348 (157.8) 4L-5 (125) 93/4" (247.6) 3/8" (98.4) 4/8" (111.1) 1/2".13 2015 (8.96) 380 (172.3) (150) 111/2 (292.1) 5" (127.0) 51/8" (130.2) 1/2"13 2015 (8.96) 640 (290.3) i 41-6 41-8 1 (200) 1 131/4' (336.5) 1 55/8" (142.8) 55/8" 1 (142.9) 1 1/2"13 1 2015 (8.96) 728 1 (330.2) * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? the installation angle measured from the vertical. Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper 13-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. I - I COOPER B-Line Fig. 4L I Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" Size Range: One size fits bracing pipe 1" (25mm) thru 2' (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31 .7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component I of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and Cooper B-LineiTOLCO 'braced pipe attachment, Fig. 1000, 1001, 2002, 4L, 4A or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. I To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 61. Note: Fig. 980 Swivel Attachment and Fig. 1001, 1000, 2002, 4A or approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish. Set Bolt Included Mounting Hardware Is Not Included 11 Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Fig. 980 Longitudinal Brace * Standard size. Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. I CO 00 OPER B-Line - - __ __ , I 111 Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 21/2" (65mm) thru 8" (200mm) IPS. * Pipe size used for bracing: 1" (25mm) and 11/4" (32mm) Schedule 40 IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1 "(25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. ØTDLCO c®us USTED UL Listed Design Load Sch. 7 - 1600 lbs. (7.11kN) Sch. 10 & 40 w/1"(25mm) Brace Pipe 2015 lbs. (8.96kN) Sch. 10 & 40 W11114" (32mm) Brace Pipe 2765 lbs. (12.3OkN) Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" (25mm) or 11/4" (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other Cooper B-Line/TOLCO bracing products. Pipe I2l/j(65)I 1001-21/2X1 Tl1i 11/4" (32mm) 1386 1(628)1 1001-2112X1114 Brace Pipe I 160.4 (72.7) Load UL (80) 1001-3X1 147.2 (66.7) 1001-3X11/4 168.7 (75) UL (100) 1001-4X1 160.9 (13.0) 1001-4X11/4 182.4 (82]) UL 6" (150) 1001-6X1 190.0 (86.2) 1001-6X11/4 211.4 (959) UL 8" 1 (200) 1001-8X1 1 217.4 1 )98.6) 1 1001-8X11/4 238.8 1 (108.3) UL See load ratings in UL Listed Design Load chart. * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? is the installation angle measured from the vertical. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 65. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. I I All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 00 COOPER B-Line MODEL 1000 3/4" 1" 11/4" 11/2" 2" I I I Li I I I Li The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System. I Li The Model 1000 Complies With All Requirements Of NFPA-1 3, NFPA-1 3R, And NFPA-13D. Li The Model 1000 TESTANDRAIN Is A Single Handle Ball Valve That Is Light Weight I And Compact, Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. Li Available In A Full Range Of Sizes From 3/4" To 2" NPT & BSPT, With All Specifiable Orifice Sizes /8", 7/1ó", 1/21, 17/3211,5/8!1 (ELO), 3/4" (ESFR) and K.25. Li The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. Li The Standard Model 1000 TESTANDRAIN Valve Includes A Pressure Gauge Port Tapping And Can Be Ordered With A Relief Valve As A Model 1011 Or 101 1T Li Locking Kit Available Which Provides Superior Vandal Resistance And Prevents Unintentional Alarm Activation. 00 out New Aj0 Visit US on the Internet at I I I SIZE A B C D E F G H 3/Is 5 1/,6" 1 l/2U 2 'io" 3 /&' 3 /8" 1 134 4 iio" 6 3/511 128mm 37.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm 1" 5 i/loll 1 1/2" 2 i16" 3 4" 3 I&' 1 13/16 4 io" 6 3i" 128mm 37.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm 1 1/ " 4 5 116U 137.70mm 1 11i16 42.70mm 2 9116u 65.36mm 4 1/4" 108.36mm 35/1611 82.84mm i 15/1611 50.89mm 59/1611 141.39mm 5 1/211 192.28mm 6 71jel 1 13/1611 3 /" 5 /io" 3 is" 2 51e" 8 1/4" 10 71el 2 163.38 mm 45.50mm 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm 2" 6 'io" 1 13/loll 3 1/411 5 /16 3 /" 2 i8" 8 1/4" 10 718u _________ 163.38mm 45.50mm 81.50mm I 127mm 99.18mm 66.97mm 206.63mm 273.60mm MATERIAL LIST PART: MATERIAL: HANDLE STEEL STEM ROD BRASS BALL C.P. BRONZE BODY BRONZE SIGHT GLASS LEXAN® VALVE SEAT IMPREGNATED TEFLON INDICATOR PLATE STEEL HANDLE LOCK SPRING STEEL UL MODEL 1000 300 PSI -. , 3/4" 1" 11/4" 11/2" 2" IUVAI'A'1 - Of TO DRAIN 4 D FRONT VIEW/HORIZONTAL INSTALLATION ORIFICE SIZE AVAILABLE - 3/8', 17/16", 1/2", 17/32", ELO(5/8"), ESFR(3/4')* and K.25 Available on 11/2" to 2" size units only. DIMENSIONS - INCHES FRONT VIEW/VERTICAL INSTALLATION FROM BRANCH GAUGE INLET PROVIDED STREET EL TO DRAIN STREET EL _.-' F::IIIIIII1JLIIIII1 - OR PIPE I TO DRAIN RIGHT HAND/STRAIGHT INSTALLATION APPROVALS: UL and ULO Listed J FM Approved except 3/4" Fj NYC-BSA NO, 720-87-SM IJ CA. State Fire Marshall **3/4 Valve UL listed only. UL LISTING EX4019 AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 A T: (610) 240-4900/ F: (610) 240-4906 Email: info@testandrain.com Web: www.testandrain.com ® RiserPACK and TESTanDRAIN are registered trademarks of AGF JOB NAME: ARCH ITECT: ENGINEER: CONTRACTOR: 3/02 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR The Series 705W butterfly valve features an approved weatherproof actuator housing approved for indoor or outdoor use. It has a ductile iron body and disc with EPDM disc coating. The body is coated with a heat fused polyphenylene sulfide blend to meet FM requirements. Designed for fire protection services only. Series 705W valve is UL Listed and FM Approved for 300 psi/2065kPa service. The Series 705W is also LPCB approved for 20 Bar and VdS approved for 16 Bar service. Contact Victaulic for details of agency approvals. WEATHERPROOF ACTUATOR Pre-wired supervisory switches that monitor the valve in the fully open position for all sizes. OPTIONAL SUPPLY-SIDE TAP Series 705W valves are available with a ½" NPT supply side tap designed to allow direct water supply connection to Victaulic FireLock actuated fire protection valves. See separate drawings below. This is an optional feature and must be clearly noted on all orders. MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, coated with polyphenylene sulfide blend. Disc: Ductile iron conforming to ASTM A-536, various grades, EPDM coated. Disc Coating: Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Stem Bearings: Teflon impregnated fiberglass with stainless steel backing. Stem Bearing Nuts: Type 416 Stainless Steel. Tap Plug: Carbon steel, plated. 0-Ring: EPDM Bracket: Carbon steel, painted. Actuator: 2112 —8/65— 200mm Bronze traveling nut on a steel lead screw, in a ductile iron housing. 10— 12/250 — 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing. JOB/OWNER ' System No. Location CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved Date Para I www.victaulic.com vicuic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02008 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REVH \4taulic 10.181 I I PS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR DIMENSIONS - c®us IL PC- BI USTED T II L II ,i.mrao.ir.nm,.pi1;.iflVflTIIIITTmip.. 11 _J_II Each __ 2½ 2.875 3.77 8.76 4.21 6.08 3.00 0.00 0.75 8.3 65 73.0 95.6 222.5 76.2 0.0 * 19.1 3.8 76.1 mm 3.000 3.77 8.76 4.21 6.08 3.00 0.00 0.75 8.3 761 i 95.6 222.5 - 106.9 154.4 76.2 0.0 19.1 3.8 3 3.500 3.77 9.40 0.08 4.21 i 6.08 3.00 0.00 0.75 8.9 80 88.9 1 95.6 238.8 2.0 106.9 154.4 76.2 0.0 19.1 4.0 4 4.500 4.63 10.84 3.00 0.73 1.13 14.9 100 114,3 117.6 275.3 1.8 152.7 177.3 76.2 18.5 28.7 6.8 139.7mm 5.500 5.88 12.38 6.01 8.57 4.50 21.0 139.7 149.4 314,5 10.9 152,7 217.7 114.3 -9.5 5 5.563 5.88 12.38 0.43 6.01 8,57 1 4.50 . 21.0 125 141,3 149.4 314.5 10,9 152.7 217,7 1 114.3 - - I 9.5 S mm 6.500 5.88 13.41 1.00 7.51 1 9.2 4.50 1 1.60 1.88 26.5 165.1 149.4 340,6 25.4 i 190.8 236.7 1 114.3 40.6 47.8 12.0 6 6.625 5.88 13.41 1.00 7.51 9.32 4.50 1.60 1.88 26.5 150 168.3 149.4 340.6 - 25.4 190.8 236.7 114.3 1 40.6 478 12.0 8 8.625 t 5.33 16,50 1.27 9.65 1 10.98 6.30 1 0.00 * 0.68 43.0 200 219.1 135.4 419.1 32.3 245.1 24S.1 27 278.9 160.0 0.0 17.3 19.5 10 10.750 6.40 19.14 9.00 250 273.0 162.6 486,2 43.7 309.9 411.2 228.6 - - . 36.3 12 12.750 6.50 21.54 2.66 14.25 17.22 9.00 102.0 300 323.9 165.1 547.1 67,6 362.0 , 437.4 228.6 1 - 46.3 On Centerline These dimensions apply only to a Series 705W Butterfly Valve with a ½-inch NPT, supply-side tap To prevent rotation of valves. it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex, Style 005 FireLock, Style 009/009V FireLock EZ, or Style HP-70 Rigid Couplings. If Victaulic flexible couplings are used, additional support may be required. Valve must not be installed with disc in full open position. Disc must be partly closed so that no part is protruding beyond end of valve body. Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IPS) only. Not permitted for use with plain end (IPS) pipe. Series 705W valves are designed for ambient weather conditions as opposed to submersible service. !F ••-•!r .LiII I I liii J I Illilli 2½ - 4-INCH/65 - 100-MM SIZES u' 1i 11111k IIUIiI' 1111111' 5 - 12-INCH/125 - 300-MM SIZES www.victaulic.com vIcTAuLIC IS REGISTERED TRADEMARK OF VICTAULEC COMPANY. © 2008 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. 10.18 ,2 As-ta-ulicr REVH PS CARBON STEEL PIPE - FIRE PROTECTION VALVES FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR DIMENSIONS- CE c®us zf3' FL-PCBI 0026 LISTED lit II 11 Dimensions ao.*oiop I flWTh1IIffiflm.. II_JL 76,1mm 3.000 3.77 8.76 i 4.21 6.08 4.50 0.00 0.75 8.3 76.1 95.6 222.5 - 106.9 154.4 114.3 0.0 .19.1 3.8 3 3.500 3.77 1 9.40 0.08 4.21 6.08 4.50 0.00* 0.75 8.9 80 88.9 95.6 238.8 2.0 106.9 154411143 0.0 19.1 40 4 4.500 4.63 10.84 0.07 6.01 6.98 4.50 0.73 1.13 14.9 100 114.3 117.6 275.3 1.8 152.7 177.3 114.3 18.5 28.7 6.8 139.7mm 5.500 5.88 12.38 0.43 6.01 8.57 7.87 21.0 139.7 149.4 314.5 10.9 152.7 217.7 200 - - 9.5 6 6.625 5.88 13,41 1.00 7.51 9.32 7.87 1.60 1.88 26.5 150 168.3 149.4 340.6 25.4 190.8 236.7 200 40.6 47.8 12.0 8 8.625 5.33 16.50 1.27 9.65 , 10.98 7.87 0.00 0.68 43.0 200 219.1 135.4 419,1 32.3 245.1 278.9 200 0.0 173 19.5 10 10.750 6.40 19.14 1.72 12.20 j 16.19 9.84 80.0 250 273.0 162.6 486.2 43.7 309.9 i 411.2 250 - - 36.3 12 12.750 6.50 I 21,54 2.66 14.25 17.22 9.84 102.0 300 323.9 165.1 547.1 67.6 362.0 437.4 250 - - 46.3 On Centerline * These dimensions apply only to a Series 705W Butterfly Valve with a ½-inch NPT, supply-side tap To prevent rotation of valves, it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex Style 005 FireLock, Style 009/009V FireLock EZ, or Style HP-70 Rigid Couplings, If Victaulic flexible couplings are used, additional support may be required. Valve must not be installed with disc in full open position. Disc must be partly closed so that no part is protruding beyond end of valve body. Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IRS) only. Not permitted for use with plain end (IPS) pipe. Series 705W valves are designed for ambient weather conditions as opposed to submersible service. I.. I-ill I P! II IiI!III Ai& 11111k iIlk hUll' lull' 76.1MM - 4-INCH/65 - 100-MM NOMINAL SIZES I www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAuLIc COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. i \4t9u11cr 10.183 PS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe. 72½ , I i g i L#- -11 2.875 1651 mm 6.500 8 65 73.0 1.6 . 165.1 2.5 75.1 mm 3.000 5 6 6.625 8 76.1 1.6 150 168.3 2.5 3 3.500 5 8 8.625 11 80 88.9 1.6 200 219.1 3.4 4 4.500 12 10 10.750 12 100 114.3 3.7 250 273.0 3.7 1397 mm 5.500 12 12 12.750 14 139.7 3.7 300 323.9 1 4.3 5 5.563 12 125 141.3 3.7 MAXIMUM WORKINGS PRESSURE RATINGS Size T II Maximum Working Pressure by II II__h__ 2½ 2.875 300 300 20 - 65 73.0 76.1 mm 3.000 300 300 20 16 76.1 3 3.500 300 300 20 16 80 88.9 4 4.500 300 300 20 15 100 114.3 139.7 mm 5.500 300 300 20 16 139.7 5 5.563 300 300 20 - 25 141.3 1 155.1 6.500 300 300 20 - 165.1 6 6625 300 300 20 16 10 &625 300 300 20 8 200 219.1 16_ - 10 10.750 300 300 20 16 250 273.0 12.750 300 300 300 20 16 323.9 www.victaulic.com 'j AC- tauiic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10184 REV I I I I IPS CARBON STEEL PIPE FIRE PROTECTION VALVES FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR PERFORMANCE Cv values for flow of water at +60°F/+16°C with a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, Values: AP = Q2 Where: 0 = Flow (GPM) AP = Pressure Drop (psi) 0 = C x C = Flow Coefficient Formulas for Kv Values; AP = Q, Where: 0= Flow (a-) O = K ,< ,/" AP = Pressure (bar) K,, = Flow Factor 7-72.111 7 Kv . fl 2½ 280 139.7.. 1397 5.500 995 8 8.625 2940 65 73.0 139.7 200 219.1 761 mm 3.000 280 5 5.563 995 10 10.750 4975 76.1 125 141.3 250 273.0 3 3.500 415 165.1 mm 6.500 1600 12 12.750 7180 80 88.9 . 165.1 300 323.9 4 4.500 520 6 6.625 1600 100 114.3 150 168.3 www.victaulic.com vlcTAuLlc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVH \4tau11cff 10.185 I I I I I I I I I I I 1 I I PS CARBON STEEL PIPE FIRE PROTECTION VALVES 10.18 FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR SWITCH AND WIRING 1. The supervisory switch contains two, single pole, double throw, pre-wired switches. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps © 250 VDC Switches supervise the valve in the "open" position. One switch has two #18 MTW wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 MTW ground lead (green) is provided. Switch #1 = Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Si Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe 52 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe 1L.0 21 IN.. FIRE11R. CONTROLRANEL COSO\ swTcH —INCONNECRDRS r. 12-N. 0 25 AT 25o VDC / SO STAG S SOU ACE TO END-OF-LINE RESISTOR, OR 1E1, NO ICATOR NC I NO Co. Switch 1:2kdt p.cte,OcM S,c1c1h2:1 iecdpc,tc,mical NOTE: The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe - S2) and the normally closed terminal (blue - Si and blue-with-orange stripe - S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NEPA 70 (NEC). www.victaulic.com vlcTAuuc IS REGISTERED TRADEMARK OF viciuic COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERvED, 10.186 JtauIicr REVH I I SERIES 705W WITH WEATHERPROOF ACTUATOR WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve. Verify you have the latest revision by visiting our website at www.victaulic.com. Further reference can be found in the 1-100 Victaulic Field Installation Handbook. II II II 1111111 1111111 111111 I 11111111 11111 WCAS-71-1 FF85 For complete contact information, visit www.victaulic.com 10.18 Z466 REV H UPDATED 8/2008 iCtauIic' viciuuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. Q 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.18 I ES-F-800 Series 800 Detector Check for Automatic Fire Sprinkler Systems Size: 4" - 10" (100mm - 250mm) The FEBCO Series 800 is used in the protection of potable water supplies from unauthorized water usage. This requires installation of the proper valv- ing to measure water loss. The Series 800 Detector check is not a back- flow prevention assembly and should not be used as such. Features Simple service procedures. Cast lifting ring for ease of installation. 4", 6, 8', and 10' Sizes 3/4" standard bypass; optional sizes: 1', 11/2' and 2" End Connections - Flanged ANSI B16.42, Class 150 Operation In a non-flow condition, the mainline check and bypass check are closed and the meter is idle. All flows up to approximately 10 gpm will flow through the standard 3/4 (20mm( bypass. This operation at low flow rates is accomplished by designing the differential pressure drop across the bypass line to be slightly less than the mainline check valve. Therefore, the mainline check valve remains closed so that low flows through the fireline system are registered by the bypass meter. Flows in excess of approximately 10 gpm will open the mainline check valve causing flow to occur through the mainline assembly and the bypass line. Approvals 4", 6, 8' and 10 FM Listed Approved 800 with Optional Bypass I. Specifications Detector check shall consist of a single spring-loaded swing check in paral- lel with a bypass meter assembly. Seat rings shall be bronze, bolted to the valve bodies with an elastomer seal. The main check assembly shall be hinge guided Head loss through the assembly shall not exceed 3psi (21 kPa) at velocities from zero up to and including 15fps (4.6mps). Mainline check body and cover shall be manufactured of Ductile Iron ASTM A536 Grade 6545-12. Ductile iron bodies shall be flanged ANSI B16.42, class 150 and fusion epoxy coated 8 mils minimum to meet A.W.W.A. C550-90. Detector check shall be rated at 250p5i (172 bar( working pres- sure and be UL listed and FM approved for both horizontal and vertical installation. Disc shall be rubber encapsulated ductile iron. Detector check shall meet or exceed requirements of Underwriters Laboratory and Factory Mutual Research Corporation. Detector check shall be FEBCO Series 800 or prior approved equal. Pressure - Temperature Maximum working pressure: 250psi (172 bail Hydrostatic test pressure: 500psi (34.5 bar) Temperature range: 32°F to 110°F (0°C to 60°C( Materials Main valve body: Ductile iron Grade 65-45-12 Fusion Epoxy coated Internal and External A\MNA C550-90 Trim: Bronze Elastomers: Nitrile Spring: Stainless Steel Bypass: Bypass meter: Totalizing type GPM/CFM Size: 1/8' x 3/4 [1 I 11 I . UL listed and FM approved for horizontal or vertical installation. Spring-loaded swing check for reliability and minimum head loss. 250p5i (172 bar( working pressure for superior strength. I . DuraCast ductile iron body for superior strength and lighter weight. Fully rubber encapsulated ductile iron disc for strength. Fusion epoxy coated, inside and out, for corrosion protection. I Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise mea- surements, please contact FEBCO. FEBCO reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subse-quently sold. BYPASS SIZES I STANDARD I OPTIONAL in. mm I in. I in. mm in. mm ~ 1½ 40 2 50 4 100/ 6 150 ' V 8 $mmin. E25 200 V V V V V 10 250 / Capacity :j L •.•mu••u••uu — -- — — - - — — — — — — — — — - - MEMEMENEEMMEME ••............ ••••iu•uui . . . . . . . . . - - - ............ p ___•.••.......... L__•••IU•I•UU•IU Dimensions - Weights U.S. Patent No. 4989,635 Size: 4" - 10" (100 - 250mm) SIZE (ON) DIMENSIONS WEIGHT 1 in. I mm A in. mm B in. mm C in. mm D in. mm E in. mm F in. mm lbs. kgs. 4 100 161/2 419 121/2 318 9/4 248 41/2 114 10½ 267 11 279 76 34.5 6 150 22½ 572 17 432 135/a 346 5½ 140 11/8 295 11 279 157 71.2 8 200 26½ 673 21 533 16~ 425 6/4 171 125A 321 11 279 215 97.5 10 250 361/4 1 921 28 711 20 508 8 1 203 13/4 349 1 11 279 1 370 167.8 Dimensions shown are nominal, allowance must be made for normal manufacturing tolerances. A Watts Water Technologies Company USA: 4381 N. Brawley • Ste. 102 • Fresno, CA • 93722 • Tel. (559) 441-5300 • Fax: (559) 441-5301 • www.FEBCOonline.com Canada: 5435 North Service Rd. • Burlington, ONT. • 1-71- 5117 • Tel. (905) 332-4090 • Fax: (905) 332-7068 • www.FEBC0onhine.ca ES-F-800 0651 0 2009 FEBCO I Conterminous 48 States 2005 ASCE 7 Standard I Latitude = 33.1 Longitude = -117.20000000000002 I Spectral Response Accelerations Ss and Si Ss and Si = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 I Data are based on a 0.01 deg grid spacing Period Sa I (sec) (g) 0.2 1.046 (Ss, Site Class B) I I Tol-Brace Seismic Calculations Western Fire Protection Project Address: Sola Salon Studios 13630 Danielson Street C00 00 Poway, CA 92064 R B-Line TOLCO 1822 Marron Rd (858)513-4949 Carlsbad, CA 92008 C16588039 Job # TIC-1107 Calculations based on 2010 NFPA Pamphlet #13 Brace Information Tolco Brace Components Maximum Spacing 40'0" (12.19 m) Tolco Component Fig. Number Adjusted Load Maximum Brace Length TO" (2.13 m) Fig.1001 Clamp 1131 lbs (513 kg) Bracing Material 1" Sch.40 Fig.980 Universal Swivel 1955 lbs (887 kg) Angle from Vertical 450 Mm. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for Tolco components only. Use of any 0.42" (11 mm) other components voids these calculations and the listing of the assembly. Least Rad. of Gyration Assembly Detail LIR Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCO FIG. 98 UNIVERSAL SWAY BRACE ATTACHMENT 0 Force Factor (Cp) 0.54 STEEL PIPE LATERAL BRACE / Fastener Information I / Fastener Orientation NFPA Type H Maximum Load 330 lbs (150 kg) TOLCO FIG. 1001 Diameter 1/2in. FAST CLAMP / Length 3-1/2in. Type Through-Bolt Brace Identification on Plans Lateral 4" Main [Orientation of Brace Lateral Braced Pipe: 4" Sch.7 Steel Pipe Load Information Size and Type of Pipe Total Length 1244lbs(111 Total Calculated Load 4" Sch.7 Steel Pipe (101.6 mm) 40ft (12.2 m) kg) Percentage added for Fittings and Sprinklers 115% 37 lbs (16.78 kg) Total Adjusted Load of all pipe within Zone of Influence 280 lbs (127 kg) (Tol-Brace Version 71 [:1 I I I I I I I I I I I I I I I I I I I Tol-Brace Seismic Calculations Sola Salon Studios Job # TIC-1107 00 COOPER B-Line ®TDLCD 1822 Marron Rd Brace Identification Lateral 4" Main Brace Type (Per NFPA#13) NFPA Type H Braced Pipe 4" Sch.7 Steel Pipe Spacing of Brace 40' 0' (12.19 m) Orientation of Brace Lateral Bracing Material 1" Sch.40 Maximum Brace Length 7' 0" (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 1/2in. X 3-1/2in. Through-Bolt Length of Fastener 3-1/2in. Summary of Pipe within Zone of Influence 4" Sch.7 Steel Pipe (101.6 mm) 40ft (12.2 m) G-Factor Used 0.54 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 280 lbs (127 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 330 lbs (150 kg) Fig.1001 Clamp 1131 lbs (513 kg) Fig.980 Universal Swivel 1955 lbs (887 kg) Structural Member 4x18" Wood beam Calculations prepared by Lupita Ruiz *The description of the Structual Member is for informational purposes only. Tol-Brace software calculates the brace assembly only, not the structure it is attached to. Calculated with Tol-Brace 7 visit us at www.tolco.com I I I I I I I Li Tol-Brace Seismic Calculations Western Fire Protection Project Address: Sola Salon Studios 13630 Danielson Street 00 4k TOLCE) COOPER B-Line Poway, CA 92064 1822 Marron Rd (858)513-4949 Carlsbad, CA 92008 C16588039 Job # TIC-1107 Calculations based on 2010 NFPA Pamphlet #13 Brace Information Tolco Brace Components Maximum Spacing 10'0" (3.05 m) Tolco Component Fig. Number Adjusted Load Maximum Brace Length TO" (2.13 m) Fig.1001 Clamp 1386 lbs (629 kg) Bracing Material 1" Sch.40 Fig.980 Universal Swivel 2395 lbs (1086 kg) Angle from Vertical 60° Mm. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for Tolco components only. Use of any 0.42" (11 mm) other components voids these calculations and the listing of the assembly. Least Rad. of Gyration Assembly Detail LJR Value 200 TOLCO FIG. 980 Max Horizontal Load 1604 lbs (728 kg) UNIVERSAL SWAY BRACE ATTACHMENT Force Factor (Cp) 0.54 0 STEEL PIPE LATERAL BRACE / Fastener Information Fastener Orientation NFPA Type F 4 / Maximum Load 600 lbs (272 kg) Diameter 1/2in. TOLCO FIG. 1001 / FAST CLAMP Length 3-1/2in. Type Through-Bolt Brace Identification on Plans Lat. Orientation of Brace Lateral Braced Pipe: 3" Sch.7 Steel Pipe Load Information Size and Type of Pipe Total Length Total Calculated Load 3° Sch.7 Steel Pipe (76.2 mm) lOft (3 m) 39 lbs (18 kg) 2" Sch.40 Steel Pipe (50.8 mm) 115.25ft (35.1 m) 319 lbs (145 kg) 1" Sch.40 Steel Pipe (25.4 mm) 9.58ft (2.9 m) 11 lbs (5 kg) Percentage added for Fittings and Sprinklers 15% 55 lbs (24.95 kg) Total Adjusted Load of all pipe within Zone of Influence 424 lbs (192 kg) ITol-Brace Version 71 I I I I I I I I I I Tol-Brace Seismic Calculations Sola Salon Studios Job # TIC-1107 00 COOPER B-Line TDLCD 1822 Marron Rd Brace Identification Lat. Brace Type (Per NFPA#13) NFPA Type F Braced Pipe 3" Sch.7 Steel Pipe Spacing of Brace 10 0" (3.05 m) Orientation of Brace Lateral Bracing Material 1" Sch.40 Maximum Brace Length 7' 0" (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 600 Type of Fastener 1l2in. X 3-1l2in. Through-Bolt Length of Fastener 3-1/2in. Summary of Pipe within Zone of Influence 3" Sch.7 Steel Pipe (76.2 mm) I lOft (3 m) 2" Sch.40 Steel Pipe (50.8 mm) Ill5.25ff (35.1 m) 1" Sch.40 Steel Pipe (25.4 mm) 1 9.58ft (2.9 m) G-Factor Used 0.54 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 424 lbs (192 kg) Material Capacity 1604 lbs (728 kg) Fastener Capacity 600 lbs (272 kg) Fig.1001 Clamp 1386 lbs (629 kg) Fig.980 Universal Swivel 2395 lbs (1086 kg) Structural Member Wood Beam Calculations prepared by Lupita Ruiz *The description of the Structual Member is for informational purposes only. Tol-Brace software calculates the brace assembly only, not the structure it is attached to. Calculated with Tol-Brace 7 visit us at www.tolco.com I U Tol-Brace Seismic Calculations Western Fire Protection Project Address: Sola Salon Studios 13630 Danielson Street C00 00 R B-Line TOLCO CA 92064 Poway, 1822 Marron Rd (858)513-4949 Carlsbad, CA 92008 C16588039 Job # TIC-1107 Calculations based on 2010 NFPA Pamphlet #13 Brace Information Tolco Brace Components Maximum Spacing 40' 0" (12.19 m) Tolco Component Fig. Number Adjusted Load Maximum Brace Length TO" (2.13 m) Fig.41- Clamp 1425 lbs (646 kg) Bracing Material 1" Sch.40 Fig.980 Universal Swivel 1955 lbs (887 kg) Angle from Vertical 450 Mm. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for Tolco components only. Use of any 0.42" (11 mm) other components voids these calculations and the listing of the assembly. Assembly Detail Least Rad. of Gyration LIR Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCO FIG. 980 UNIVERSAL SWAY BRACE ATTACHMENT 021 Force Factor (Cp) 0.54 STEEL PIPE LATERAL BRACE / / 0 TOLCO FIG. 4L PIPE CLAMP FOR 0 Fastener Information Fastener Orientation NFPA Type E SWAY BRACING,--- Maximum Load 350 lbs (159 kg) Diameter 1/2in. 0 Length 3-1/2in. Type Through-Bolt -- Brace Identification on Plans Long Orientation of Brace Longitudinal ' Braced Pipe: 3" Sch.10 Steel Pipe Load Information Size and Type of Pipe Total Length Total Calculated Load 3 Sch.10 Steel Pipe (76.2 mm) 40ft (12.2 m) 172 lbs (78 kg) Percentage added for Fittings and Sprinklers 115% 26 lbs (11.79 kg) Total Adjusted Load of all pipe within Zone of Influence 197 lbs (89 kg) 4ToI-Brace Version 7) I I I I Li Tol-Brace Seismic Calculations Sola Salon Studios Job # TIC-1107 00 COOPER B-Line TOLCO 1822 Marron Rd Brace Identification Long Brace Type (Per NFPA#13) NFPA Type E Braced Pipe 3 Sch.10 Steel Pipe Spacing of Brace 40 0 (12.19 m) Orientation of Brace Longitudinal Bracing Material 1' Sch.40 Maximum Brace Length 7 0 (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 1/2in. X 3-1/2in. Through-Bolt Length of Fastener 3-1/2in. Summary of Pipe within Zone of Influence 3 Sch.10 Steel Pipe (76.2 mm) 40ft (12.2 m) I G-Factor Used 0.54 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 197 lbs (89 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 350 lbs (159 kg) Fig.4L Clamp 1425 lbs (646 kg) Fig.980 Universal Swivel 1955 lbs (887 kg) Structural Member 418 Wood Beam Calculations prepared by Lupita Ruiz *The description of the Structual Member is for informational purposes only. Tol-Brace software calculates the brace assembly only, not the structure it is attached to. Calculated with Tol-Brace 7 visit us at www.tolco.com Carlsbad Municipal Water District Ir Potable Water Discharge Event Report Date: Location: Reason for Discharge Event: --------------------'1It Type of Event Initial Dewatering Water Mains Note: Includes flow testing and flushing Dewatering Water Mains Unscheduled Water Discharge Jik Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetation. Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharged water. Estimated Discharge Flow: GPM Start Time q= End Time ------j__________ Pre-Dechiorination Residual: 2J1 Post-Dechlorination Residual: (Less than 0.1 mg/L) PH within limits of 6.0 and 9.0 I I I I I I I I I Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. Upon completion of dewatering, ensure that any sediments or silted areas are cleared. Water Sampling Performed by: Comments: I II Submitted by: Reviewed by: (Name & Date) (Name & Date) I I I blOrV lest Record Location Hydrant JD No. - Size Main Static Residual......... Pressure Drop.. (PDI 1).....K factor for PDJ 1 Flow Hydrant(s) Hydrant 1 location Hydrant 2 location Hydrant 3 location Hydrant I Pitot PSI GPM: Size of Orifice Hydrant 2 Pitot PSI GPM: Size of Orifice Hydrant 3 Pitot PSI GPM: Size of Orifice. I. A JkCLI Calculated test and flow data - 0 x PD2 k =Q2 PDI*k Static: Desired Residual.......20 Pressure Drop (PD 2).. K factor PD 2: x divided by ______ equals GPM at 20 psi residual Q PD2k PD1k Q2 Comments: Test conducted for: Conducted by: Date: Time: I I I I I I I [1 - - - Fire Protection b, Computer Design Western Fire Protection Inc. 13630 Danielson Street Poway, CA 92064 858-513-4949 Job Name : Sola Salon Building : FP-2 Location : 1822 Marron Rd. Carlsbad, CA 92008 System : 1 Contract : C-16-588039 Data File : text 1 Ext. Coverage.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I I I I I I I I I ater 6upply curve - - - - - = - M - - M - - M - Western Fire Protection Inc. Page 1 Sola Salon Date October 21, 2013 City Water Supply: Demand: Cl - Static Pressure : 91.8 Dl - Elevation : 5.414 C2 - Residual Pressure: 86.4 D2 - System Flow : 504.888 C2 - Residual Flow : 1455 D2 - System Pressure : 74.173 Hose ( Demand) : 250 D3 - System Demand : 754.888 Safety Margin : 16.023 150 140 130 120 R0 E10° Ci C9 90 S 580 2- 12 ________ u 70 / I D3 R60 E5° 40 30 20 10 ..... I I I ____________________________ • 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - - - - - - - - - - - - 1-luings used summary Western Fire Protection Inc. Page 2 Sola Salon Date October 21, 2013 Fitting Legend Abbrev. Name 1/2 % 1 11/4 11/2 2 21/2 3 31A 4 5 6 8 10 12 14 16 18 20 24 Bvcb B Fly Vic 705W 0 0 0 0 0 0 5 5 0 12 12 8 11 12 14 0 0 0 0 0 C Roll Groove Coupling 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Pressure I Flow Summary - STANDARD Western Fire Protection Inc. Sola Salon 2013 Page 3 Date October 21, Node Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. No. Si 25.0 5.6 10.31 na 17.98 0.2 1 7.0 S2 25.0 5.6 10.3 na 17.98 0.2 1 7.0 S3 9.5 11.2 12.1 na 38.96 0.2 1 12.1 S4 9.5 11.2 12.52 na 39.63 0.2 1 12.1 S5 9.5 11.2 12.98 na 40.35 0.2 1 12.1 S6 9.5 11.2 14.17 na 42.16 0.2 1 12.1 S7 12.0 5.6 25.63 na 28.35 0.2 1 7.0 S8 12.0 5.6 25.72 na 28.4 0.2 1 7.0 S9 12.0 5.6 26.03 na 28.57 0.2 1 7.0 S10 12.0 5.6 26.59 na 28.88 0.2 1 7.0 Sli 12.0 5.6 18.51 na 24.09 0.2 1 7.0 U S12 9.5 5.6 19.08 na 24.46 0.2 1 7.0 S13 9.5 5.6 19.3 na 24.6 0.2 1 7.0 S14 9.5 11.2 14.93 na 43.28 0.2 1 12.1 S15 9.5 5.6 20.05 na 25.08 0.2 1 7.0 9.5 5.6 21.04 na 25.68 0.2 1 7.0 S16 S17 9.5 5.6 22.31 na 26.45 0.2 1 7.0 1 21.167 12.59 na 2 21.167 12.59 na A15.167 15.22 na 3 15.167 15.68 na 4 15.167 16.13 na 5 15.167 16.8 na 6 15.167 18.53 na 7 15.167 26.97 na 8 15.167 27.07 na 9 15.167 27.4 na 15.167 28.02 na 10 11 15.167 19.23 na 12 15.167 19.25 na 13 15.167 19.41 na 14 15.167 19.76 na 15.167 20.48 na 15 16 15.167 21.36 na 17 15.167 22.78 na Ri 15.167 25.67 na R2 15.167 30.29 na R3 15.167 26.99 na Ml 14.5 32.71 na M2 14.5 33.04 na M3 14.5 33.81 na M4 14.5 42.08 na TOR 18.0 61.37 na BOR 0.5 70.8 na UG -3.0 72.54 na 3.0 70.16 na UG1 SF1 3.0 70.38 na BF2 -3.0 73.37 na UG2 -3.0 73.59 na SRC -3.0 74.17 na 250.0 I The maximum velocity is 18.78 and it occurs in the pipe between nodes M3 and M4 I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Final Calculations - Hazen-Williams - 2007 Western Fire Protection Inc. Page 4 Sola Salon Date October 21, 2013 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. Point Qt "C" Pf/Ft or Eqv. Ln. Ftng's Total Pe Pv Pf Pn Notes Si 17.98 1.049 1E 2.0 3.833 10.309 K Factor =5.60 to 120.0 0.0 2.000 1.660 1 17.98 0.1070 0.0 5.833 0.624 Vel = 6.67 1 0.0 17.98 12.593 K Factor = 5.07 S2 17.98 1.049 1E 2.0 3.833 10.305 K Factor = 5.60 I to 120.0 0.0 2.000 1.660 2 17.98 0.1068 0.0 5.833 0.623 Vel = 6.67 0.0 12.588 K Factor = 5.07 I 17.98 S3 38.96 1.049 1E 2.0 6.500 12.100 KFactor= 11.20 to 120.0 iT 5.0 7.000 -2.454 3 38.96 0.4467 0.0 13.500 6.031 Vel = 14.46 I 0.0 38.96 15.677 K Factor= 9.84 39.63 1.049 1E 2.0 6.167 12.518 K Factor= 11.20 I S4 to 120.0 iT 5.0 7.000 -2.454 4 39.63 0.4611 0.0 13.167 6.071 Vel = 14.71 0.0 I 39.63 16.135 K Factor = 9.87 S5 40.35 1.049 1E 2.0 6.167 12.977 K Factor = 11.20 to 120.0 iT 5.0 7.000 -2.454 40.35 0.4766 0.0 13.167 6.276 Vel = 14.98 I5 0.0 40.35 16.799 K Factor = 9.84 42.16 1.049 1E 2.0 6.167 14.172 K Factor = 11.20 I S6 to 120.0 iT 5.0 7.000 -2.454 6 42.16 0.5172 0.0 13.167 6.810 Vel = 15.65 0.0 I 42.16 18.528 K Factor = 9.79 S7 28.35 1.049 1 E 2.0 3.920 25.633 K Factor = 5.60 to 120.0 1 5.0 7.000 -1.372 I 7 28.35 0.2482 0.0 10.920 2.710 Vel = 10.52 0.0 28.35 26.971 K Factor = 5.46 I S8 28.40 1.049 1E 2.0 3.920 25.718 K Factor = 5.60 to 120.0 iT 5.0 7.000 -1.372 8 28.4 0.2490 0.0 10.920 2.719 Vel = 10.54 0.0 I 28.40 27.065 K Factor = 5.46 S9 28.57 1.049 1 E 2.0 3.920 26.026 K Factor = 5.60 1 5.0 7.000 -1.372 I to 120.0 9 28.57 0.2517 0.0 10.920 2.749 Vel = 10.61 0.0 28.57 27.403 K Factor= 5.46 I S10 28.88 1.049 1E 2.0 3.920 26.588 K Factor = 5.60 to 120.0 1 5.0 7.000 -1.372 10 28.88 0.2568 0.0 10.920 2.804 Vel = 10.72 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc. Page 5 Sola Salon Date October 21, 2013 Hyd. Qa Dia. Fitting Pipe Pt Pt - Ref. Point Qt "C" Pf/Ft or Eqv. Ln. Ftngs Total Pe Pv Pf Pn ******* Notes I 0.0 28.88 28.020 K Factor = 5.46 1.049 1E 2.0 4.420 18.508 K Factor= 5.60 I Sill 24.09 to 120.0 1 5.0 7.000 -1.372 11 24.09 0.1836 0.0 11.420 2.097 Vel = 8.94 0.0 I 24.09 19.233 K Factor= 5.49 S12 24.46 1.049 1E 2.0 6.920 19.077 K Factor = 5.60 to 120.0 iT 5.0 7.000 -2.454 ' 12 24.46 0.1888 0.0 13.920 2.628 Vet = 9.08 0.0 24.46 19.251 K Factor = 5.57 I S13 24.60 1.049 1E 2.0 6.420 19.298 K Factor = 5.60 to 120.0 1 5.0 7.000 -2.454 13 24.6 0.1908 0.0 13.420 2.561 Vet = 9.13 0.0 I 24.60 19.405 K Factor = 5.58 S14 43.28 1.049 1E 2.0 6.420 14.931 K Factor = 11.20 1 5.0 7.000 -2.454 I t0 120.0 14 43.28 0.5426 0.0 13.420 7.282 Vet = 16.07 0.0 43.28 19.759 K Factor= 9.74 S15 25.08 1.049 1E 2.0 7.590 20.051 K Factor = 5.60 to 120.0 iT 5.0 7.000 -2.454 15 25.08 0.1977 0.0 14.590 2.885 Vet = 9.31 I 0.0 25.08 20.482 K Factor = 5.54 S16 25.68 1.049 1E 2.0 6.420 21.036 K Factor = 5.60 120.0 1 5.0 7.000 -2.454 I to 16 25.68 0.2067 0.0 13.420 2.774 Vet = 9.53 0.0 21.356 K Factor = 5.56 I 25.68 S17 26.45 1.049 1E 2.0 6.420 22.307 K Factor= 5.60 to 120.0 iT 5.0 7.000 -2.454 17 26.45 0.2183 0.0 13.420 2.929 Vet = 9.82 I 0.0 26.45 22.782 K Factor = 5.54 1 17.98 2.203 1E 6.819 2.250 12.593 I to 120.0 0.0 6.819 2.599 A 17.98 0.0029 0.0 9.069 0.026 Vet = 1.51 0.0 15.218 K Factor = 4.61 '17.98 2 17.98 2.203 1E 6.819 3.833 12.588 to 120.0 0.0 6.819 2.599 17.98 0.0029 0.0 10.652 0.031 Vet = 1.51 I A A 17.98 2.203 2E 13.639 17.000 15.218 to 120.0 iT 13.639 27.278 0.0 I 35.96 0.0104 0.0 44.278 0.459 Vet = 3.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - Western Fire Protection Inc. Page 6 Sola Salon Date October 21, 2013 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3 38.96 2.203 0.0 11.330 15.677 to 120.0 0.0 0.0 0.0 74.92 0.0404 0.0 11.330 0.458 Vet = 6.31 I 4 4 39.62 2.203 0.0 7.500 16.135 to 120.0 0.0 0.0 0.0 5 114.54 0.0885 0.0 7.500 0.664 Vet = 9.64 5 40.35 2.203 0.0 11.167 16.799 to 120.0 0.0 0.0 0.0 6 154.89 0.1548 0.0 11.167 1.729 Vel= 13.04 I 6 42.16 2.203 iT 13.639 15.920 18.528 to 120.0 0.0 13.639 0.0 Ri 197.05 0.2416 0.0 29.559 7.142 Vel= 16.59 0.0 I 197.05 25.670 K Factor = 38.89 7 28.35 2.203 0.0 14.000 26.971 120.0 0.0 0.0 0.0 I to 8 28.35 0.0067 0.0 14.000 0.094 Vel = 2.39 8 28.40 2.203 0.0 14.000 27.065 to 0.0 0.0 0.0 I 120.0 9 56.75 0.0241 0.0 14.000 0.338 Vel = 4.78 9 28.57 2.203 0.0 12.000 27.403 to 120.0 00 0.0 0.0 85.32 0.0514 0.0 12.000 0.617 Vel = 7.18 I 10 10 28.88 2.203 iT 13.639 12.167 28.020 to 120.0 0.0 13.639 0.0 R2 114.2 0.0880 0.0 25.806 2.272 Vet = 9.61 I 0.0 114.20 30.292 K Factor = 20.75 24,09 2.203 0.0 3.680 19.233 I 11 to 120.0 0.0 0.0 0.0 12 24.09 0.0049 0.0 3.680 0.018 Vel = 2.03 12 24.46 2.203 0.0 8.500 19.251 I to 120.0 0.0 0.0 0.0 13 48.55 0.0181 0.0 8.500 0.154 Vel = 4.09 13 24.60 2.203 0.0 9.167 19.405 120.0 0.0 0.0 0.0 I to 14 73.15 0.0386 0.0 9.167 0.354 Vel = 6.16 14 43.28 2.203 0.0 7.920 19.759 120.0 0.0 0.0 0.0 I to 15 116.43 0.0913 0.0 7.920 0.723 Vet = 9.80 15 25.07 2.203 0.0 6.670 20.482 to 120.0 0.0 0.0 0.0 I 16 141.5 0.1310 0.0 6.670 0.874 Vet = 11.91 16 25.69 2.203 0.0 8.000 21.356 to 120.0 0.0 0.0 0.0 167.19 0.1782 0.0 8.000 1.426 Vel = 14.07 I 17 17 26.45 2.203 iT 13.639 4.333 22.782 to 120.0 0.0 13.639 0.0 I R3 193.64 0.2339 0.0 17.972 4.204 Vel = 16.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Final Calculations - Hazen-Williams Western Fire Protection Inc. Page 7 Sola Salon Date October 21, 2013 Hyd. Qa Dia. Fitting Pipe Pt Pt • Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I 0.0 193.64 26.986 K Factor= 37.28 197.05 2.203 2T 27.277 0.670 25.670 I Ri to 120.0 0.0 27.277 0.289 Ml 197.05 0.2416 0.0 27.947 6.753 Vet = 16.59 0.0 I 197.05 32.712 KFactor= 34.45 R2 114.20 2.203 2T 27.277 0.670 30.292 to 120.0 0.0 27.277 0.289 I M2 114.2 0.0881 0.0 27.947 2.461 Vet = 9.61 0.0 114.20 33.042 K Factor= 19.87 I R3 193.64 2.203 2T 27.277 0.670 26.986 to 120.0 0.0 27.277 0.289 M3 193.64 0.2339 0.0 27.947 6.538 Vet = 16.30 0.0 I 193.64 33.813 K Factor= 33.30 Ml 197.05 3.314 0.0 10.000 32.712 120.0 0.0 0.0 0.0 I to M2 197.05 0.0330 0.0 10.000 0.330 Vel = 7.33 M2 114.20 3.314 0.0 10.000 33.042 120.0 0.0 0.0 0.0 I to M3 311.25 0.0771 0.0 10.000 0.771 Vet = 11.58 M3 193.64 3.314 1E 10.191 33.670 33.813 to 120.0 0.0 10.191 0.0 504.89 0.1886 0.0 43.861 8.270 Vet = 18.78 I M4 M4 0.0 4.31 9E 125.433 271.290 42.083 to 120.0 0.0 125.433 -1.516 504.89 0.0524 0.0 396.723 20.805 Vet= 11.10 I TOR TOR 0.0 4.26 lBvcb 15.8 17.500 61.372 to 120.0 0.0 15.800 7.579 504.89 0.0555 0.0 33.300 1.848 Vet = 11.36 I BOR BOR 0.0 6.16 2L 19.415 5.000 70.799 to 120.0 0.0 19.415 1.516 UG 504.89 0.0092 0.0 24.415 0.225 Vet = 5.44 I UG 0.0 6.16 2L 25.822 6.000 72.540 to 140.0 0.0 25.822 -2.599 UG1 504.89 0.0069 0.0 31.822 0.221 Vet = 5.44 0.0 6.09 2L 27.75 6.000 70.162 I UG1 to 150.0 0.0 27.749 0.0 BF1 504.89 0.0064 0.0 33.749 0.217 Vet = 5.56 0.0 6.16 1C 1.63 6.000 70.379 I BF1 to 150.0 1G 4.89 58.675 2.599 BF2 504.89 0.0061 1S 52.156 64.675 0.394 Vet = 5.44 BF2 0.0 6.16 2L 29.338 6.000 73.372 I to 150.0 0.0 29.338 0.0 UG2 504.89 0.0061 0.0 35.338 0.216 Vet = 5.44 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Final Calculations - Hazen-Williams Western Fire Protection Inc. Page 8 Sola Salon Date October 21, 2013 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. Point Qt "C" or Pf/Ft Eqv. Ln. Ftng's Total Pe Pv Pf Pn Notes I UG2 0.0 6.09 1G 4.625 40.000 73.588 to 150.0 iT 46.249 50.874 0.0 SRC 504.89 0.0064 0.0 90.874 0.585 Vel = 5.56 I 250.00 Qa = 250.00 1 I I I I I I 754.89 74.173 K Factor= 87.65 I I I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087