Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3207 GREY HAWK CT; ; FS110003; Permit
1/3/25, 9:10AM FS110003 Permit Data City of Carlsbad Fixed Systems Permit 3207 GREY HAWK Job Address: CT Permit Type: FIXSYS Parcel No: 2210150100 - Lot #: 0 Reference No.: Permit No: FSII0003 Status: ISSUED Applied 3/3/2011 Approved: 3/3/2011 Issued: 3/3/2011 PC #: Inspector: Project Title: 3E COMPANY SPECIAL CHEMICAL SUPPRESSION SYSTEM Applicant: Owner: JAM FIRE PROTECTION INC CONCOURSE ONE LLC 8254 RONSON RD C/O LEE PACHECO 130 VANTIS #200 ALISO VIEJO CA 858-495-2335 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 3//O003 JAM Fire Protection, Inc. 8254 Ronson Rd. San Diego, CA. 92111 (858) 495-2335 FAX (858) 496-3820 FIRE PROTECTION. INC. Letter of Transmittal To: City of Carlsbad Date: 3/15/2011 Job No. 11 SRW2549F 1635 Faraday Ave. Attention: Fire Prevention / Greg Ryan Carlsbad, CA. 92008 Re: Ansul, Inergen, gas fire suppression system 3E Company 3207 Greyhawk Court Carlsbad, CA. 92010 Revision I - plan issue #3 We are sending you attached, by hand, the following items: Date Sheet Description 3 3/14/2011 FS-1 Cover Sheet 3 3/14/2011 ES-2 System Layout 3 3/14/2011 FS-3 Details 3 3/14/2011 FS-4 Control Panel Schematic & Info 3 3/14/2011 Data Sheets & Inergen system Hydraulic calculations These are transmitted as indicated below: +This plan is submitted for review & approval. +Please return one copy with your stamp of approval and/or comments. +This revised plan is per Greg Ryan's/CFD plan review comments to the initial plan submittal dated 3-2-11. Thank you, SIGNATURE b-e'~ ___________________ Dennis Buth Lead Designer Office: (858) 495-2335 Fax: (858) 496-3820 dennis.buth@jamfire.com Copy to: File 'T ILE COPY Fire Protection, Inc. 8254 Ronson Rd. San Diego, CA. 92111 Phone (858) 495-2335, Fax (858) 496-3820 CUT-SHEETS FOR Project Info: 3E Company 3207 Greyhawk Ct. Carlsbad, CA. 92010 Scope of Work: Installation of an Ansul, Inergen (IG-541), inert gas fire suppression system in the Server Roomrhe Inergen system will utilize an Autopulse, Z-10, agent release control panel for the detection and control functions. Design By: Dennis Buth Lead Designer 858-495-2335 dennis.buth@jamfire.com AP DASSU!T ED CAARLSBAD F!RE )EPARTMENT Hydraulic Flow CaIcs for the Ansul, Inergen System ANSUL INERGEN DESIGNER Version 2.1.2 File: Data file: Y:\Drawings\Engineered\San Diego\3E Company\JAM docs\Calcs\1 1 SRW2459F_Fixed . mr Job: 11SRW2549F Customer: 3E Company Address: Palomar Concourse One 3207 Greyhawk Court, Suite 200 Carlsbad CA. 92010 Country: USA REMARKS: System protecting Server Room 216. Hazard Area Information Area: Server Room 216 Design concentration 34.2% at 65° Fahrenheit Estimated maximum concentration 40.1% at maximum hazard temperature 75° Fahrenheit Gross volume of enclosure 7887 cubic feet Structural volume reductions 117.0 cubic feet Net volume of enclosure 7769.7 cubic feet Minimum INERGEN required 3286.6 cubic feet Approximate INERGEN supplied 3951. cubic feet Flooding factor .423 cubic feet of INERGEN per cubic feet of enclosure volume Maximum allowable wall strength 5.0 lbs./sq.ft. Area consists of one volume Volume 1: Length 38.1 ft Width 23 ft Height 9 ft 2 nozzles. Nozzle identifiers: 301, 302 Agent Storage Conditions Number of cylinders: 9 each containing 439 cubic feet of INERGEN. Total agent 3951 cubic feet Engineering units (ft, cu ft, psia) are specified Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Pipe Data Input Sec Sec Nominal Length Elev 90's Side Thru Union! Qty EqI Start End Pipe Size (ft) (ft) Tee Tee Cplg cu ft (ft) 1 2 1/2-40T 0.01 0.00 0 0 0 0 38.00 2 3 1 1/2-80T 1.00 0.00 1 0 0 0 0.00 3 4 1 1/2-80T 1.00 0.00 0 0 1 0 2cy1 0.00 4 5 1 1/2 - 80 T 0.50 0.00 0 0 1 0 3 cyl 0.00 5 6 1 1/2-80T 1.00 0.00 0 1 0 0 4cy1 0.00 6 7 1 1/2 - 80 T 1.50 0.00 0 0 2 0 8 cyl 0.00 7 8 1 1/2 - 80 T 0.50 0.50 0 0 1 0 9 cyl 0.00 8 9 0 - 80 T 0.00 0.00 0 0 0 0 Orifice 9 10 11/2-40T 3.00 3.00 0 0 0 0 0.00 1 (Data Input File Printout continued) ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved W.I.) 2Y0A9.AF. ULC listed CEx1151 Version 2.1.2 File: Data file: Y:\Drawings\Engineered\San Diego\3E CompanyJAM docs\Calcs\1 I SRW2459F_Fixed. mr Job Number: 11SRW2549F e Data Input(Continued) File: Data file: Y:\Drawings\Engineered\San Diego\3E Company\JAM docs\Calcs\1 I SRW2459F Fixed. mr Sec Sec Nominal Length Elev 90's Side Thru Union! Qty Eqi Start End Pipe Size (ft) (ft) Tee Tee Cplg Qty (ft) 10 11 0-40T 9.00 0.00 1 0 0 0 0.00 11 12 0-40T 13.50 0.00 0 1 0 0 0.00 12 13 0-40T 12.50 0.00 1 0 0 0 0.00 13 301 0-40T 1.00 -1.00 1 0 0 0 1975.50 0.00 11 14 0 -40 T 13.90 0.00 0 1 0 0 0.00 14 15 0-40T 1.30 0.00 1 0 0 0 0.00 15 16 0-40T 10.40 0.00 1 0 0 0 0.00 16 17 0-40T 11.30 0.00 1 0 0 0 0.00 17 302 0-40T 1.00 -1.00 1 0 0 0 1975.50 0.00 2 (End of Data Input File Printout) ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 Version 2.1.2 File: Data file: Y:\Drawings\Engineered\San Diego\3E Company\JAM docs\Calcs\1 I 8RW2459F_Fixed. mr Job Number 11 SRW2549F for 3E Company Address: Palomar Concourse One 3207 Greyhawk Court, Suite 200 Carlsbad CA. 92010 Country: USA REMARKS: System protecting Server Room 216. Aaent Storaae Conditions Storage pressure is 2175 psia at 70 degrees Fahrenheit. 439 cubic feet of INERGEN stored in each of 9 cylinders. Total agent in storage is 3951 cubic feet. Time to discharge 3556 cubic feet (90% of INERGEN) is 76.7 seconds Maximum pressure downstream of manifold orifice is 1307 psia Concentrations 95% Maximum Minimum Requested Time Cu Ft Concentration Concentration Concentration \rea Volume (sec) INERGEN at Max. Temp. at Mm. Temp. at Min Temp. erver Room 216 7769.7 55 3951.0 40.1% at 75°F 39.6% at 65°F 34.2% at 65°F Sea level equivalent oxygen: 12.6% at 75°F Free Vent Calculation Peak Maximum Wall Minimum Free rea Rate Strength Vent Area Server Room 216 7841.1 cfm 5.0 Ibs./sq.ft. 300 sq. in. Pressure Drop Results Sec Sec Nominal Length Equiv Elev Tee/ Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 1 2 1/2 40T 0.0 38.0 0.0 MELD 1033 1006 449. 2 3 11/2 80T 1.0 4.8 0.0 MFLD 1006 1007 449. 3 4 1 1/2 80 T 1.0 3.5 0.0 MELD 1007 1007 898. 4 5 11/2 80T 0.5 3.0 0.0 MFLD 1007 1007 1347. 5 6 11/2 80T 1.0 8.5 0.0 MELD 1007 1005 1796. 6 7 11/2 80T 1.5 6.5 0.0 MELD 1005 1000 3592.1 7 8 11/2 80T 0.5 3.0 0.5 MELD 1000 998 4041.1 1 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 Version 2.1.2 File: Data file: Y:\Drawings\Engineered\San Diego\3E CompanyJAM docs\Calcs\1 I SRW2459F_Fixed . mr Job Number: 11 SRW2549F essure Drop Results (Continued) Sec Sec Nominal Length Equiv Elev Tee/ Start Term Flow 3tart End Pipe Size (if) Length(if) (if) Mfld psia psia (cfm) 8 9 ORIFICE .563 INCHES DRILL NO. 9/16 998 435 4041.1 9 10 11/2 401 3.0 3.0 3.0 435 584 4041.1 10 11 11/2 401 9.0 13.0 0.0 584 575 4041.1 11 12 11/4 40T 13.5 20.4 0.0 BULL 575 570 1976.1 12 13 11/4 401 12.5 16.0 0.0 570 564 1976.1 13 301 11/4 401 1.0 4.5 -1.0 564 562 1976.1 11 14 11/4 401 13.9 20.8 0.0 BULL 575 569 2065. 14 15 11/4 401 1.3 4.8 0.0 569 567 2065. 15 16 11/4 401 10.4 13.9 0.0 567 561 2065. 16 17 11/4 401 11.3 14.8 0.0 561 555 2065. 17 302 11/4 401 1.0 4.5 -1.0 555 553 2065. Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Pipe and Fittings Sec Sec Nominal Length Side Thru Unions/ Eql tart End Pipe Size (if) 90's Tee Tee Cplgs (if) 1 2 1/2 401 0.0 0 0 0 0 Cyl Valve 38 ft 2 3 11/2 801 1.0 1 0 0 0 3 4 11/2801 1.0 0 0 1 0 4 5 11/2 801 0.5 0 0 1 0 5 6 11/2801 1.0 0 1 0 0 6 7 11/2801 1.5 0 0 2 0 7 8 11/2 801 0.5 0 0 1 0 8 9 1 1/2 80 1 0 0 0 0 Man. Orifice 9 10 11/2 401 3.0 0 0 0 0 10 11 11/2 401 9.0 1 0 0 0 11 12 11/4 401 13.5 0 1 0 0 12 13 11/4 401 12.5 1 0 0 0 2 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved W.I.) 2Y0A9.AF, ULC listed CEx1151 Version 2.1.2 File: Data file: Y:\Drawings\Engineered\San Diego\3E Company\JAM docs\Calcs\1 I SRW2459F_Fixed. mr Job Number: 11SRW2549F e and Fittincis(Continued Sec Sec Nominal Length Side Thru Unions/ Eqi tart End Pipe Size (if) 90's Tee Tee Cplgs (if) 13 301 11/4 40T 1.0 1 0 0 0 11 14 11/4 40T 13.9 0 1 0 0 14 15 11/4 40T 1.3 1 0 0 0 15 16 11/4 40T 10.4 1 0 0 0 16 17 11/4 40T 11.3 1 0 0 0 17 302 11/4 40T 1.0 1 0 0 0 Nozzle Performance Summary ozzIe Nominal Drill Drill Quantity (cu if) Area slumber Pipe Size Number Diameter Discharged Name 301 11/4 40T 9/16 0.562 1939.7 Server Room 216 302 11/4 40T 37/64 0.578 2011.3 Server Room 216 ,ssaqes/Errors ANSUL 150 bar INERGEN DESIGNER Version number 2.1.2 Calculation done on 2/28/2011 at 2:42:52 PM e schedule selected for pipe sizes downstream of the manifold orifice is based on the maximum e pressure for Grade A-53B, A-i 06B Seamless. To determine if other grades are acceptable, rify that the maximum pipe pressures for other grades are equal to or greater than the maximum ticipated downstream pressure. Calculation by JAM Fire Protection Dennis Buth 8254 Ronson Rd. San Diego CA. 92111 USA Telephone: 626-256-4400 Fax: 858-496-3820 3 End of Printout Ansul, Inergen (IG-541) 150 Bar INERT GAS FIRE SUPPRESSION SYSTEM DATA SHEETS ANSUL Ineçci Ckan Ag ANSUL INERGEN® 150-BAR SYSTEM DESIGN, INSTALLATION, RECHARGE AND MAINTENANCE MANUAL ANSUL PART NO. 416655-11 UNDERWRITERS LABORATORIES FILE NO. EX-4510 MARCH 1, 2006 @2006 Ansul Incorporated ANSUL® System Components UL EX-4510 3-1-06 Page 1-1.1 REV. 4 !eflAeJS® CV-98 Valve/Cylinder Shipping Assembly Description The cylinder is factory filled with INERGEN® agent. A single cylinder may be used or multiple cylinders can be manifold- ed together to obtain the required quantity of agent for total flooding. The cylinder valve can be actuated electrically, pneumatically, and/or manually with approved valve actua- tion components. All valves are equipped with an anti-recoil feature. The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck of each cylinder. This cap entirely encloses and protects the valve while in shipment. The equivalent length of the valve is equal to 20 ft. (6.1 m) of 1/2 in. Sch. 40 pipe. Component Material Approvals Cylinder Steel Meets DOT 3AA2300 Valve Brass Safety Relief Valve Brass Valve/Cylinder Assembly FM Approved UL Listed (EX-4510) Shipping Cap Steel Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Standard Paint 426147 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426148 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426149 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426620 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426594 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426150 435* (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies - Red Corrosion Resistant Paint 426256 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426257 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426258 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426621 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426595 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426259 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) * NOTE: For Shanghai version, order Part No. 430935. Canadian TC Approved Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Enamel Paint 426712 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426713 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426714 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427551 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426715 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies - Red Epoxy CR Paint 426716 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426717 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426718 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427552 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426719 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) CYLINDER SHIPPING CAP 0 PRESSURE VALVE SHIPPING CAP GAUGE RECORD VALVE TAG HEIGHT TO OUTLET CENTER 002251 3 1/2 IN. PRESSURE (89 mm) GAUGE REFERENCE SAFETY RELIEF VALVE - \ / / 002252 CV-98 INERGEN Valve The CV-98 valve has a ten (10) year warranty. The valve requires no internal maintenance. The valve is sealed closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be sent back to Ansul for warranty replacement. If the exter- nal seal is broken, the warranty is voided. NOTE: Use Flexible Discharge Bend, Part No. 427082, when attaching valve to supply pipe or manifold. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. Tyco SAFETY PRODUCTS, MARINETrE, WI 54143-2542 715-735-7411 Form No. F-9877-4 ©2006 Ansul Incorporated ANSUL System Components UL EX-4510 11-1-00 Page 1-3.6 PflAe Jte 1 Booster Actuator Description The Booster Actuator, Part No. 428949, is used when elec- tric actuation is required on the 1 in. selector valve, 2 in. selector valve, or the CV-98 cylinder valve. The actuator mounts directly to the component and then a HF electric actuator mounts to the top of the booster actuator. The Booster Actuator requires resetting after actuation. A Reset Tool, Part No. 429847, is available for this use. 11/4-18 UNEF 11/8-18 UNEF 006037 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETrE, WI 54143-2542 715-735-7411 Form No. F-2001066 ©2001 Ansul Incorporated ANSUL® lift AeLJtem® Description Electrical actuation is accomplished by an HF electric Actuator, Part No. 73327, interfaced through an AUTOPULSE® Control System. This actuator can be used in hazardous, indoor environments where the ambient tem- perature range is between 0 OF to 130 OF (-18 °C to 54 °C). The HF electric actuator meets the requirements of N.E.C. Class I, Div. 1, Groups B, C, D and Class II, Div. 1, Groups E, F, G. A maximum of two HF electric actuators can be used on a single AUTOPULSE release circuit. When utiliz- ing only one HF electric actuator, an in-line resistor, Part No. 73606, is required in the supervised release circuit. In auxiliary or override applications, a manual-local override valve actuator or a manual cable pull actuator can be installed on top of the HF electric actuator by removing the safety cap. An arming tool, Part No. 75433, is required to reset the actuator after operation. The actuator contains a standard 1/2 in. threaded female straight connector for electrical con- duit hookup. Technical Information Nominal Voltage: ..........12 VDC @ 0.57 amps Rated Voltage: Minimum: ...................12.0 VDC Maximum: ...................14.0 VDC Thread Size/Type ........1/2 in. straight female for electrical conduit hookup Material: Body ........................Brass Plunger: .................Stainless Steel System Components UL EX-4510 11-1-00 Page 1-3.7 HF Electric Actuator Listings and Approvals UL .........................E91021 ULC ..........................1165 FM . . . . . . . . . . . . . . . . . . . . . . . . 2T8A9.AF 2 1/4 IN. (57 mm) n) ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINEUE, WI 54143-2542 715-735-7411 Form No. F-2001067 02001 Ansul Incorporated I. ANSUL® 1InAeLJte® Description The manual lever release actuator provides a manual means of actuating cylinder valves and selector valves. This can be accomplished by direct manual actuation of its pull lever or cable actuation when used in conjunction with a remote manual pull station. When used with a remote manual pull station, the pull station must contain the com- ponents necessary to meet the actuator lever traveling requirements of 7 in. (178 mm). The actuator is shipped with ring pin and chain attached. If the ring pin is not required, it must be removed. Failure to remove the ring pin/chain assembly will prevent system actuation if a remote cable pull actuation system is employed and the ring pin is accidentally installed in the actuator. Four actuators are available. Each is designed for a specific component. Add 1 9/16 in. (3.9 Cm) to height when lever is in the straight up position. System Components UL EX-4510 3-1-06 Page 1-4.1 REV. 4 Lever Release Actuator Component Material Approvals All Manual Brass with FM Approved Cable-pull Stainless UL Listed Actuators Steel Pin (EX-451 0) Shipping Assembly Part No. Description 842484 Lever Release (1 1/4-18 mounting thread) - Mounts directly to pressure actuator on 2 1/2 in., 3 in. and 4 in. selector valves. 423309 Lever Release (1 1/8-18 mounting thread) - Mounts directly to a CV-98 electric actuator. Mounts directly to a CV-98 cylinder valve. 70846 Lever Release (1 1/4-18 mounting thread) - Mounts directly to an HF electric actuator. 427207 Lever Release (1 1/8-18 mounting thread) - Mounts directly to the 1 in. and 2 in. selector valves. Mounts directly to pressure operated stackable actuator for 1 in. and 2 in. selector valves. Actuator has the handle painted red. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. Tyco SAFETY PRODUCTS, MARINE11E, WI 54143-2542 715-735-7411 Form No. F-9879-4 02006 Ansul Incorporated ANSUL® 1IflAeLjtO Description The valve Flexible Discharge Bend (Part No. 427082) is a 5/8 in. (1.59 cm) I.D. extra-heavy flexible hose which con- nects the valve discharge outlet to the fixed piping or head- er manifold. The discharge bend has a special female thread for connecting to the valve outlet and a male 1/2 in. NPT thread for connecting to the fixed piping or manifold. The discharge bend will withstand a pressure of 9000 psi (621 bar). Its flexible connection allows for easy alignment of multiple cylinder banks to fixed piping. Each bend has a built-in check valve that prevents loss of agent should the system discharge while any cylinder is removed. The equivalent length of this hose is equal to 18 ft. (5.5 m) of 1/2 in. Sch. 40 pipe. System Components UL EX-4510 3-1-06 Page 1-12 REV. 5 Flexible Discharge Bend Shipping Assembly Part No. Description 427082 Flexible discharge bend 842430 Washer D. Component Material Thread Size/Type Approvals Valve End Manifold End 5/8 in. Flexible SAE 100 R2 Special to mate 1/2 in. NPT Male FM Approved Discharge Bend Type AT mate with CV90 UL Listed (EX-451 0) and CV-98 Valve 187/8 IN. p (47.9 cm) FEMALE ADAPTOR (BRASS) 1/2 IN. NPT WASHER MALE COUPLING CHECK SWAGE ON VALVE END .........Øf . 1MANIFOLDIEND 000658 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINErrE, WI 54143-2542 715-735-7411 Form No. F-9306-7 02006 Ansul Incorporated * DIRECTI OF FLO VISIBLE ORIFICE IDENTIFICATION 002197 ANSUL® 11flAejt.® System Components UL EX-4510 3-1-06 Page 1-15 REV. 7 Pressure Reducer/Union Description The pressure reducer/union is required to restrict the flow of INERGEN® agent thus reducing the agent pressure down stream of the union. The 3000 psi (206.9 bar) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The orifice union is available in six sizes: 1/2 in., 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., and 2 in. NPT. All pressure reducer/unions must be installed in the piping with the orifice identification tab on the pressure inlet side of the system. The 1 1/4 in., 1 1/2 in. and 2 in. orifice unions must be installed per the direction of the flow arrow stamped on the body. Shipping Assembly Part No. Description A B C 416677 1/2 in. NPT pressure reducer/union 2.06 in. (5.2 cm) 1.18 in. (2.9 cm) 1.95 in. (4.9 cm) 416678 3/4 in. NPT pressure reducer/union 2.38 in. (6.1 cm) 1.50 in. (3.8 cm) 2.38 in. (6.1 cm) 416679 1 in. NPT pressure reducer/union 2.63 in. (6.7 cm) 1.78 in. (4.5 cm) 2.77 in. (7.0 cm) 416680 1 1/4 in. NPT pressure reducer/union 2.94 in. (7.5 cm) 2.04 in. (5.2 cm) 3.31 in. (8.4 cm) 416681 1 1/2 in. NPT pressure reducer/union 3.31 in. (8.4 cm) 2.31 in. (5.9 cm) 3.70 in. (9.4 cm) 416682 2 in. NPT pressure reducer/union 3.56 in. (9.0 cm) 2.85 in. (7.2 cm) 4.39 in. (11.2 cm) Component Material Thread Size Approvals Pressure Reducer! Body: Forged 1/2, 3/4, 1, FM Approved Union Steel 1 1/4,1 1/2, UL Listed (EX-4510) 2 in. NPT Orifice Plate: Stainless Steel NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. Orifice diameter must be specified when placing order. ANSLJL and INERGEN are trademarks of Ansul Incorporated or its affiliates. rico SAFETY PRODUCTS, MAFRINErrE, WI 54143-2542 715-735-7411 Form No. F-9311-9 ©2006 Ansul Incorporated System Components UL EX-4510 11-1-00 Pagel-16.1 REV. 2 1800 Discharge Nozzle Shipping Assembly Part No. Description 426138 1/4 in. NPT nozzle 426139 3/8 in. NPT nozzle 426140 1/2 in. NPT nozzle 426141 3/4 in. NPT nozzle 426142 1 in. NPT nozzle 426143 1 1/4 in. NPT nozzle 426157 11/2 in. NPT nozzle 426144 2 in. NPT nozzle 426145 21/2 in. NPT nozzle 426146 3 in. NPT nozzle b. Size A-in. B-In. C-In. 1/4 in. 5/8 19/16 21/32 3/8 in. 3/4 15/8 23/32 1/2 in. 15/16 1 31/32 27/32 3/4 in. 1 1/8 25/32 7/8 1 in. 113/32 29/16 1 1 1/4 in. 13/4 23/4 1 1/16 11/2 in. 2 231/32 11/16 2in. 23/8 3 1 21/2in. 3 31/2 1 3 in. 31/2 41/8 1 1/4 ANSUL® 11nAeLjeeI® Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. The 1800 nozzle is commonly used when nozzle placement is at the wall. Standard nozzles are constructed of brass. An index mark is stamped on the bottom of the nozzle to indicate the aiming direction. Component Material Thread Size Nozzle Body: Brass 1/4, 3/8, 1/2, 3/4, 1, 1 1/4,11 1/2, 2, 2 1/2,3 NPT NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. (rKr- I - A 002743 * Orifice diameter must be specified when ordering nozzle. Refer to Orifice Size Chart in Manual Appendix Section. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETIE, WI 54143-2542 715-735-7411 Form No. F-99020-1 02001 Ansul Incorporated ANSUL® Description The INERGEN® system nozzle deflector shield is used to control the pattern of the discharge of the INERGEN agent. The deflector shield helps keep the agent discharge away from false ceiling tiles and fragile light fixtures, avoiding damage to them. The deflector shields are constructed of steel and painted with a cameo cream colored paint. They are available in five sizes. System Components UL EX-4510 3-1-06 Page 1-16.2 REV. 1 Nozzle Deflector Shield Component Material Approvals Nozzle Steel FM Approved Deflector UL Listed (EX-4510) Shield Shipping Assembly Part No. A Inlet NPT B Length of Coupling C Overall Length D Deflector O.D. E Coupling O.D. 417708 1/2 in. 17/8 in. 3m. 33/8 in. 11/8 in. (4.8 cm) (7.6 cm) (8.6 cm) (2.9 cm) 417711 3/4 in. 2in. 31/4in. 33/Bin. 13/Bin. (5.1 cm) (8.3 cm) (8.6 cm) (3.5 cm) 417714 1 in. 23/8in. 313/l6in. 47/Bin. 13/4in. (6.0 cm) (9.7 cm) (12.4 cm) (4.4 cm) 417717 11/4in. 25/Bin. 43/l6in. 47/Bin. 21/4in. (6.7 cm) (110.6 cm) (12.4 cm) (5.7 cm) 417720 11/2in. 31/Bin. 429/32in. 521/32in. 21/2in. (7.9 cm) (12.5 cm) (14.4 cm) (6.4 cm) NOTE: There are no deflector shields available for the 2, 2 112, or 3 in. models. 4-E--. A I I 003651 D ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-94152-2 ©2006Ansul Incorporated ANSUL® System Components UL EX-4510 3-1-06 Page 1-17 1flAeJe® REV.8 Cylinder Bracketing Description The cylinder bracketing is designed to rigidly support the installed INERGEN® agent cylinders. The bracketing com- ponents are constructed of heavy structural steel. Bracket assemblies are available in modules for two to six cylinders and can also be connected together for any combination over six. Bracketing can be assembled to support single row, double row or back-to-back rows of cylinders. Bracketing components are painted with a red enamel coat- ing. Uprights and back frame assemblies can be bolted or welded together, which ever makes the installation more convenient. Component Material Approvals Bracketing Steel FM Approved UL Listed (EX-4510) Shipping Assembly Part No. Description 845120 200 ft.3 (5.7 m3) cylinder strap (single cylinder) 845244 200 ft.3 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 845121 250 ft.3 (7.1 m3) cylinder strap (single cylinder) 845261 250 ft.3 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) 845122 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder strap (single cylinder) 845245 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder channel with nuts and bolts (single cylinder) 879638 Back frame assembly (2 cylinder) 879639 Back frame assembly (3 cylinder) 879640 Back frame assembly (4 cylinder) 879641 Back frame assembly (5 cylinder) 879642 Back frame assembly (6 cylinder) 873257 Upright, for 200, 250, 350, and 435 ft.3 (12.3 m3) cylinders (used either for right side, left side or center (center upright required when connecting seven or more cylinders in a row)) 426592 Upright, for 425 ft.3 (12.0 m3) cylinder (used either for right side, left side, or center (center upright required when connecting seven or more cylinders in a row)) 873553 Single row or back-to-back row bracket foot (left side) 873554 Single row or back-to-back row bracket foot (right side) 873555 Double row bracket foot (left side) 873556 Double row bracket foot (right side) 418508 Center upright foot 879413 Connector (required to hook together back frames for seven or more cylinders) 873250 10.5 in. (26.7 cm) carriage bolt with nut (for single row 200 ft.3 (5.7 m3) cylinders) 873251 11 in (27.9 cm) carriage bolt with nut (for single row 250 ft.3 (7.1 m3) cylinders) 873252 12.5 in. (31.8 cm) carriage bolt with nut (for single row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418502 13 in. (33.0 cm) carriage bolt with nut (for single row 435 ft.3 (12.3 m3) cylinders) 873253 21 in. (53.3 cm) carriage bolt with nut (for double row 200 ft.3 (5.7 m3) cylinders) 873254 22 in. (55.9 cm) carriage bolt with nut (for double row 250 ft.2 (7.1 m3) cylinders) 873255 26 in. (66 cm) carriage bolt with nut (for double row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418503 27 in. (68.6 cm) carriage bolt with nut (for double row 435 ft.3 (12.3 m3) cylinders) 873091 Cylinder clamp (2 cylinders) 873092 Cylinder clamp (3 cylinders) 871683 Weigh rail support - single row 871682 Weigh rail support - double row 871684 Weigh rail support - back-to-back rows 423027 Weigh rail support back-to-back double row Multi-Cylinder WEIGH RAIL SUPPORT 'I I I II II I I II II I I II Ii I I I I •Ii I I Ii I I I I II I Single Cylinder UPRIGHT BACK FRAME CYLINDER CLAMP CARRIAGE BOLT WITH NUT RIGHT / CLAMP BRACKET FOOT CHANNEL LEFT BRACKET FOOT 002200 ANSUL and INERGEN are trademarks of Ansut Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINErrE, WI 54143-2542 715-735-7411 Form No. F-9309-8 02006AnsuI Incorporated ANSUL® 1flA Oi Description The pressure switch is operated by the INERGEN® agent pressure when the system is discharged. The pressure switch can be used to open or close electrical circuits to either shut down equipment or turn on lights or alarms. The double pole, single throw (DPST) pressure switch is con- structed with a gasketed, water tight housing. The housing is constructed of malleable iron, painted red. A 1/4 in. NPT pressure inlet is used to connect the 1/4 in. pipe from the INERGEN system. System Components UL EX-4510 3-1-06 Page 1-18 REV. 4 Pressure Switch - DPST The pressure switch can be installed either before or after the pressure reducer in the distribution piping. Minimum operating pressure is 50 PSI (3.5 bar). Shipping Assembly Part No. Description 846250 Pressure switch - DPST Component Material Thread Size/Type Electrical Rating Approvals Pressure Switch Switch: Conduit Inlet: 3/4 in. NPT Female 2 HP - 240 VAC/ FM Approved DPST BAKELITE Pressure Inlet: 1/4 in. NPT Female 480 VAC UL Listed (EX-4510) Housing: 2 HP - 250 VDC, Malleable 30A - 250V AC/DC Iron 5A - 480V AC/DC Piston: Brass Cover: Brass 35/8 IN. 1-4 (9.2 cm) MALLEABLE IRON - -. BRASS RESET 27/8 IN. I FINISH - RED PAINT ' - PLUNGER (7.3 cm) TO ELECTRICAL I EQUIPMENT TO MOISTURE-PROOF I I \\ BE CONTROLLED JOINT ] -GASKET NUT I I O" RING GASKET I I I - I NAMEPLATE 10 DOUBLE POLE - I HEAVY DUTY I TOGGLE SWITCH I 49/16 IN. (11.5 cm) I WITH FULLY ENCLOSED lo 0 BAKELITE BASE I BRASS PISTON I I II I PISTON "O RING ® I GASKET TO POWER 1. 3/4 IN. I 004593 ELECTRICAL - - MOUNTING HOLE - I I CONDUIT 19/64 IN. (7.5 mm) OUTLETS LL_JJ 1/4 IN. UNION —ø..j - J TYP. 2 PLACES 1/4 IN. PIPE L —1 FROM CYLINDERS 000716 BAKELITE is trademark of Union Carbide Corp. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-9327-6 ©2006 Ansul Incorporated ANSUL System Components UL EX-4510 3-1-06 Page 1-23 REV. 1 LflAetjem1 Warning Plate - Inside Room With Alarm Description The warning plate is available for mounting inside the haz- ard area to warn the personnel to vacate the hazard area when the alarm sounds. The warning plate is furnished with four mounting holes for ease of installation. The plate is constructed of aluminum. Shipping Assembly Part No. Description 416265 Warning Plate - inside room with alarm Component Material Mounting Hole Size Approvals Warning Plate Aluminum 1/4 in. (.64 cm) FM Approved UL Listed (EX-4510) 1200 WHEN ALARM SOUNDS VACATE AT ONCE INERGEN® AGENT BEING RELEASED men LABEL NO. 416265 ANSIJL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINE1IF, WI 54143-2542 715-735-7411 Form No. F-9315-3 ©2006 Ansul Incorporated 7.00 002746 ANSUL® 1!flAeLJtOm1 System Components UL EX-4510 3-1-06 Page 1-24 REV. 2 Warning Plate - Outside Room Without Alarm Description The warning plate is available for mounting outside the hazard area to warn the personnel that the space is pro- tected by an INERGEN® system and no one should enter after a discharge without being properly protected. The warning plate is furnished with four mounting holes for ease of installation. Shipping Assembly Part No. Description 416266 Warning Plate - outside room Component Material Mounting Hole Size Approvals Warning Plate Aluminum 7/32 in. (.56 cm) FM Approved UL Listed (EX-451 0) 8.00 0 WARNING THIS SPACE IS PROTECTED BY AN INERGEN® FIRE SUPPRESSION SYSTEM. WHEN SYSTEM IS DISCHARGED AS A RESULT OF FIRE, CAUTION MUST BE TAKEN TO AVOID EXPOSURE TO PRODUCTS OF COMBUSTION. DO NOT ENTER WITHOUT APPROVED SELF- CONTAINED BREATHING APPARATUS OR UNTIL VENTILATION HAS BEEN OPERATED FOR AT LEAST 15 MINUTES. Ineri@i I5IW553 LABEL NO. 416266 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. T'4J0 SAFETY PRODUCTS, MARINEUE, WI 54143-2542 715-735-7411 Form No. F-9314-4 ©2006Ansul Incorporated 7.00 002747 AUTOPULSE, Z=10 AGENT RELEASE CONTROL PANEL DATA SHEETS ANSUL INCORPORATED ANSU L. MARINETI1E, WI 54143-2542 COMPATIBLE COMPONENTS LIST - AUTOPULSE® Z-10, Z-28, AND Z-28 EXT Actuators for Z-10 and Z-28: 423684 CV-98 Electric Actuator 426876 CV-90 Electric Actuator 73327 HF Electric Actuator 73111 Solenoid Valve Electric Actuator 17728 ANSULAUTOMAN II-C and 31492 570537 24VDC Electric Actuator FM Approved Water Control Valves for Z-10: FM Automatic Water Control Valves Groups A through H Abort Supervision Module for Z-10: 431196 Abort Supervision Module Options and Accessories for Z-1 0: 430529 4 Point Auxiliary Relay Module 430530 External Battery Meter Module 430531 Class A Adapter Module 2-Wire Smoke and Heat Detectors for Z-10, and SLCnet ZAMs: 430559 Photoelectric Detector 2.8% ULI 430695 Photoelectric Detector 2.8% ULC 430560 Photoelectric Heat Detector ULI 430696 Photoelectric Heat Detector ULC 430561 Ionization Detector ULI 430697 Ionization Detector ULC 430562 Photoelectric Detector 3.5% ULI 430565 Heat Detector 135° ULI 430699 Heat Detector 135° ULC 430566 Heat Detector 200° ULI 430700 Heat Detector 200° ULC 2-Wire Detector Bases and Accessories for Z-10, and SLCnet ZAMs: 430567 2-Wire Base w/ LED Driver ULI 430701 2-Wire Base w/ LED Driver ULC 430569 2-Wire Base w/ Auxiliary Alarm Relay ULI 430702 2-Wire Base w/ Auxiliary Alarm Relay ULC 430570 2-Wire Base w/Remote LED Driver ULI 430703 2-Wire Base w/Remote LED Driver ULC 430572 Remote LED Alarm Indicator ULI 430704 Remote LED Alarm Indicator ULC FM Approved Water Control Valves for Z-28: FM Automatic Water Control Valves Groups A, B, D, E, F, G, and H Analog Smoke and Heat Sensors for Z-28: 430631 Photoelectric Sensor ULI and ULC 430632 Ionization Sensor ULI 430717 Ionization Sensor ULC 430633 Heat Sensor ULI 430718 Heat Sensor ULC 430634 Photoelectric/Heat Multi-Sensor ULI 430719 Photoelectric/Heat Multi-Sensor ULC Analog Sensor Bases and Accessories for Z-28: 430636 Standard Sensor Base ULI 430720 Standard Sensor Base ULC 430637 Sensor Base w/Remote Driver ULI 430721 Sensor Base w/Remote Driver ULC 430638 Sensor Base w/Relay and Remote Driver ULI 430722 Sensor Base w/Relay and Remote Drive ULC 430639 Sounder Base w/Remote Driver ULI 430723 Sounder Base w/Remote Driver ULC 430640 Isolator Base ULI 430724 Isolator Base ULC 430641 Multi-Sensor Sounder Base w/Driver ULI 431187 Multi-Sensor Sounder Base w/Driver ULC 430642 Multi-Sensor Standard Base w/Driver ULI 431188 Multi-Sensor Standard Base w/Driver ULC 430643 Supervised Relay 430644 Remote LED Indicator 430645 Unsupervised Relay ULI 431189 Unsupervised Relay ULC Analog Duct Sensors and Accessories for Z-28: 430654 4-wire Duct Housing w/Relay ULI 431190 4-wire Duct Housing w/Relay ULC 430655 Remote Test Station Duct Sensor 430586 Tube for 12 in. (30.5 cm) Duct 430587 Tube for 13 in. —23 in. (33-58 cm) Duct 430588 Tube for 24 in. - 46 in. (61-117 cm) Duct 430589 Tube for 46 in. - 71 in. (117-180 cm) Duct 430590 Tube for 71 in. - 95 in. (117-241 cm) Duct Non-Addressable Detectors: 4727 140 °F (60 °C) Vertical Rate Compensated 404751 160 °F (71 °C) Vertical Rate Compensated 13970 190 °F (88 °C) Vertical Rate Compensated 13976 225 °F (107 °C) Vertical Rate Compensated 13975 325 °F (163°C) Vertical Rate Compensated 13974 450 °F (232°C) Vertical Rate Compensated 13971 600 °F (315 °C) Vertical Rate Compensated 13977 725 °F (385 °C) Vertical Rate Compensated 71226 190 °F (88 °C) Horizontal Rate Compensated 71227 225 °F (107 °C) Horizontal Rate Compensated 71228 275 °F (135 °C) Horizontal Rate Compensated 71229 325 °F (163 °C) Horizontal Rate Compensated 417934 UV/IR, Model 20/20LB 417935 IR, Model 20/201 426302 UV/IR, Model DCRI Addressable Manual Release Stations and Accessories for Z-28: 430671 Double Actuation Push/Pull Addressable 430594 Release Label Kit 430596 Cast Aluminum Surf Box Red 430597 Steel Box Surface Red 430599 Replacement Break-Rod 430600 Red Surface Trim Plate Double Gang Box 430601 Red Surface Trim Plate Wiremold 430602 Flush Mount Adapter Kit Black 430603 Flush Mount Adapter Kit Beige Coil Supervision Module for Z-10, Z-28, and AUTOPULSE Z-28 EXT: 430687 2 Amp Coil Supervisory Module External Battery Chargers for Z-10, Z-28, and AUTOPULSE Z-28 EXT: 430548 50Ah Charger 120V Red 430550 50Ah Charger 240V Red Transient Protection Devices for Z-10, Z-28, and AUTOPULSE Z-28 EXT: 431197 Isolated Loop Circuit Protector for IDCs 430685 Isolated Loop Circuit Protector for NACs 430686 Overvoltage Protector for lAM and ZAM lDCs, SLCnet and N2 Communications Non-Addressable Manual Release Stations for Z-10: 428655 Dual Action Manual Release SPST 428656 Dual Action Manual Release DPST 428657 Dual Action Manual Release Explosion Proof Accessories for Z-28 and Z-10: 76494 Abort Switch - Surface Mount 76495 Abort Switch - Flush Mount 65956 Explosion Proof Abort Switch - Flush Mount 76498 Key Maintenance Switch - Surface Mount 76499 Key Maintenance Switch - Flush Mount 76496 Main/Reserve Switch - Surface Mount 76497 Main/Reserve Switch - Flush Mount Compatible Components List - AUTOPULSE® Z-10, Z-28, and Z-28 EXT SLCnet lAMs, ZAMs, and Accessories for Z-28: 430660 Supervised lAM 430661 Surface Trim Plate lAM 430662 Surface Trim Plate lAM 430663 1AM Mounting Bracket 430664 Relay lAM 430665 Class B ZAM w/4-wire Detector Reset 430666 Class A ZAM 430667 Surface Trim Plate RIAM/ZAM 430668 Surface Trim Plate RIAM/ZAM Suppression Release Peripheral and Accessories for Z-28: 431193 Suppression Release Peripheral and Enclosure 430657 Suppression Release Peripheral 430658 Suppression Release Peripheral LED 430659 Suppression Release Peripheral Box LCD Annunciator for Z-28: 430628 LCD Annunciator Options and Accessories for Z-28: 430710 Alarm Supervisory Trouble Relay Module 430606 2 Point Class A NAC Adapter 430610 Dual R5232/Modem Board 430611 Expansion Power Supply 120V 430612 Suppression Power Supply Kit 120V 430617 Battery Meter Module 430619 Expansion Power Supply 240V 430620 Suppression Power Supply Kit 240V 430621 24VDC Distribution Block 430622 120V Auxiliary Relay Kit 430693 Semi-Flush Trim Red 431195 24 Point I/O Module AUTOPULSE Z-28 EXT Panels and Accessories for Z-28: 430674 AUTOPULSE EXT 120 VAC Red 430675 AUTOPULSE EXT 240 VAC Red 431191 AUTOPULSE Ext 120 VAC Red ULC 430676 4 Point NAC Expansion Card 430677 2 Point Class A Adapter 430684 EXT Battery Cabinet 18Ah RED Notification Appliances Z-10, Z-28, and AUTOPULSE Z-28 EXT: 417805, 417806 Alarm Bell 429694, 429695, and 429696 Electronic Sounder with Strobe 429698 Multi Candela Strobes 65947 Explosion-Proof Electronic Sounder 429697 Electronic Sounder ANSLJL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-2003091-1 ©2006 Ansul Incorporated AUTOPULSE* Z-10 AGENT RELEASE CONTROL PANEL Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (lDCs) Two notification appliance circuits (NACs) Two release appliance circuits (RACs) Two special purpose monitor inputs (SPMs) for manual release request and manual abort request Three auxiliary relays with selectable functions Easily selected activity timing options Agent release operation includes: Automatic extinguishing release Deluge and preaction sprinkler system release Dual or single hazard area protection . Combined agent release and preaction operation* lDCs are selectable for cross-zoning or for activation from a single detection input . Short circuit RAC supervision Operator interface provides: Status LEDs per circuit for Alarm, Trouble, and Supervisory (where appropriate) Acknowledge, alarm silence, and system reset Operating mode and timer selection when in programming mode 'Audible Escalation of Events: Single Audible Appliance Tone: Stage 1 activates Temporal or 20 bpm March Time pattern; Stage 2 activates 120 bpm March Time pattern to indicate release timer active; Release activates On Steady to indi- cate release timer expired and actuator is activated Dual Audible Appliance Control* (Single Hazard): RAC 2 provides a third NAC for dedicated Stage 1 Bell control; NACs 1 & 2 indicate release as On Steady Compatible with Listed/Approved 24 VDC coil automatic water control valves Required system components: Coil supervision module, Part No. 430687, one per solenoid control RAC Maintenance Switch, Part No. 433936 or 433937, one per solenoid control RAC Recommended accessory (where appropriate): Abort Switch: - Part No. 433940, Flush Mount * Requires software revision 4.01 or higher ---------------------------- AGENT DISCHARGE PATH A CYLINDER VALVE AGENT ACTUATOR SOURCE CIRCUIT COIL SUPERVISORY :MODULE MAINTENANCE SWITCH SPM1 RAC RAC NAC 1 SPM 2 DC1 = = IDCs 2, NAC 2 IIIIIIIIIIIIlIIIIlIIllIIIIIIIIIItIfflhiI j 006554 AUTOPULSE Z-1 0 Agent Release Control Panel One-Line System Reference Drawing Dedicated for Agent Release: AUTOPULSE® Z-1 0 Suppression Release Panels provide conventional fire alarm control circuits and are equipped with the features required for a wide variety of single or dual hazard suppression release applications. Capabilities include automatic extinguishing agent release and deluge and preaction sprinkler control. Flexible I/O Capabilities: Four lDCs allow for either four separately monitored zones or two, cross-zoned connections. Two SPMs allow dedicated manual inputs for release or abort. Two releasing appliance circuits (RACs) supervise to the actuator coils and activate the actuators when required. The two NACs and the three panel auxiliary relays provide status condition information. Easy Program Selections: The operator panel has a program mode that allows selection of panel operation type and detailed operating selections using an easily selected sequential programming operation. History Log: The last 50 events are stored in non-volatile memory. This information is accessed by connecting a technician's computer to the service port which is also used to set the date and time. Operator Panel: the operator panel has alarm and trouble status indi- cating LEDs for each input and output, visible through the locking cabinet door. Unlocking the door provides access to the Acknowledge, Alarm Silence, and System Reset push-button switches. Four Class B lDCs provide coverage for either two cross-zoned areas or four separately zoned areas. lDCs are capable of supporting up to 30 current-limited smoke detectors or electronic heat detectors as well as manual stations and other compatible contact closure initiating devices. lDCs are capable of Class A operation with an optional adapter module and can be programmed as Class C (short or open initiates a trouble) for use with current limited devices only. Single hazard agent release m. applications monitor low pressure switches on 1DC3 and tamper P. switches with 1DC4. ANEL FEATURE DESCRIPTION(Continued) Two Class B Special Purpose Monitoring Circuits (SPMs) are dedi- cated for manual release or abort, waterfiow and supervisory, or release/abort and pressure, depending on system type. Inputs are normally open switches. An abort switch stops release while activated and upon deactivation, the release operation occurs after a selectable time delay. Manual release inputs override abort switches and activate the release after selectable delays of from 0 to 30 seconds in 5 second increments. For Dual Hazard applications, current limited abort operation is required. SPMs are programmable as Style C and capable of Class A operation with the optional adapter module. Two Class B NACs are provided for reverse polarity, notification appli- ance operation, each rated 2 A. Class A operation is available with the optional adapter module. NAC operation is selectable per application. Two Class B Release Appliance Circuits (RACs): Rated 2 A each, these circuits are dedicated to operating release control actuators. RAC cutout timing is selectable as no cutout, 45 seconds, or 1, 3, 3.5, 4, 5, 6, 7, 21, 25, 34, 44, or 64 minutes. For bell/horn/strobe single hazard appli- cations, RAC 2 functions as a third NAC (NAC 3). Auxiliary Power Output: Rated at 750 mA, this output can be wired as continuous or as resettable. Resettable is normally used to power 4-wire smoke detectors. Standard Auxiliary Relay Outputs: Three relays outputs are available, selectable as normally open or normally closed, rated 2 A @ 30 VDC. Trouble Relay (Aux Relay 1) is energized when Normal and is de-ener- gized with a Trouble condition. For Single Hazard Operation: Aux Relay 2 is the Alarm relay and Aux Relay 3 indicates Time Delay Started or can optionally be selected as a Supervisory relay. For Dual Hazard Operation: Aux Relay 2 is for Hazard Area 1 Alarm; Aux Relay 3 is for Hazard Area 2 Alarm. Power Supply and Battery Charger: During alarm, the power supply provides 3 A at 25.5 VDC, filtered and regulated. The temperature compensated battery charger provides 27.5 VDC for charging batteries suitable for up to 90 hour standby and 10 minutes of alarm. External battery chargers and cabinets can be used for more battery backup. Automatic Agent Release Systems: These systems automatically acti- vate solenoid control valves for the release of a fire extinguishing agent in response to fire detection device input. Automatic Extinguishing Release Systems with Separate Bell Control (single hazard) (SW rev. 4.01 or higher). RAC 2 operates as a bell control NAC. When cross-zoned, stage 1 alarm activates the bell until the release timer starts. When not cross-zoned, stage 1 alarm acti- vates the bell until expiration of the release timer. In both cross-zoned and non cross-zoned applications, NAC2 may be programmed to indi- cate either a tamper switch supervisory condition or the start of the release timer using a cadence pattern operation. UL and FM Extinguishing Release System Panels must have a minimum of 24 hours of standby power. Initiating devices must be Listed/Approved for the application, and may be wired either Class A or B. Actuators must be electrically compatible with the control panel circuits and power supplies, and are wired Class B to provide coil super- vision. Deluge and Preaction Sprinkler Systems automatically activate water control valves in response to fire detection device input. Deluge Sprinkler Systems employ open sprinkler heads and provide water flow when the fire detection system activates a common automatic water control valve. They are used to deliver water simultaneously through all of the open sprinkler heads. This type of system is applicable where the immediate application of large quantities of water over large areas is the proper fire response. Preaction Sprinkler Systems are similar to deluge systems except that normally closed sprinkler heads are used and supervisory air pressure is maintained in the pipe. Operation requires both an activated sprinkler head and an activated fire alarm initiating device. Combined Agent Release and Preaction Systems provides agent release and preaction control. (Available with software revision 4.01 or higher.) For applications where agent release may not be sufficient for fire control, sprinklers are put in preaction mode to allow waterflow to continue the fire response. (Preaction is assumed, selected deluge could be provided, determined by the sprinkler installation, panel opera- tion is the same.) UL requirements for Fire Alarm Systems Listed for Automatic Release or Deluge and Preaction Sprinkler Systems are the same as described above for Automatic Extinguishing Release Systems. FM Approved requirements for Fire Alarm Systems for Automatic Release of Deluge and Preaction Sprinkler Systems require operation of specific compatible FM Approved Automatic Water Control Valves, a minimum secondary power capacity of 90 hours, and all circuits for the automatic release initiating devices must be capable of operation during a single open circuit fault condition (Class A). I"i i.J 'J *•I PRODUCT 1 I z(. j [.J RELEASE CONTROL PANEL Part No. I Description Reference 430525 Basic Releasing Panel, Includes: Four lDCs, two operates with AC input of: NACs, two SPMs, two 120/220/230/240 VAC, RACs, 3 A power supply 50/60 Hz (auto-select) with battery charger, cabinet and door EXPANSION MODULES Part No. Description Reference 430529 Auxiliary Relay Module; four Two relays, Form C, rated 7 A @ maximum 120 VAC, 5 A @ 30 VDC, unsupervised contacts Select as 430531 Two Circuit Class A Adapter Four required Module for lDCs, SPMs, maximum or NACs Batteries Part No. Description Reference 417692 7.0 AH Battery Pack, 24 VDC Select one battery shipping assembly per 417693 12 AH Battery Pack, 24 VDC system standby requirements; two batteries are included 417694 17 AH Battery Pack, 24 VCD Requires external battery cabinet 417695 25 AH Battery Pack, 24 VDC Release Control System Modules Part No. Description 430687 Coil Supervision Module, one required per RAC; refer to pages 6 and 7 for detail 433936 Maintenance Switch, one required per RAC or 433937 433940 Abort Switch 431196 Abort Supervision Module FM FM Group ''1•- Manufacturer Model Number Details A Skinner LV2LBX25 24 VDC, 11 W, 458 mA, 1/2 in NPS, 1/2 in orifice B ASCO T8210A107 24 VDC, 16.8W, 700 mA, 1/2 in NPS, 5/8 in orifice 8210A107 R8210A107 C Star Sprinkler 5550 24 VDC, part of Model D deluge valve 0 ASCO 8210G207 24 VDC, 10.6W, 440 mA, 1/2 in NPS, 1/2 in orifice V2648571, N.C. HV2648581, N.O. E Skinner 73218BN4UNLVNOC111C2 24 VDC, 10W, 420 mA, 1/2 in NPS, 5/8 in orifice 73212BN4TN00N0C111C2 24 VDC, 10W, 420 mA, 1/2 in NPS, 5/8 in orifice; 5-300 psi rated working pressure F Skinner 73212BN4TNLVN0C322C2 24 VDC, 22W, 1/2 in NPS, 920 mA, 250 psi (1725 kPa),1/2 in orifice G Skinner 71395SN2ENJ1NOH111C2 24 VDC, 10 W, 420 mA, 1/4 in NPS, 1/16 in orifice, 250 psi (1725 kPa) rated working pressure H Viking HV-274-060-001 24 VDC, 22.6 W, 940 mA, 1/2 in NPS, 250 PSI (1725 kPa), 3/4 in orifice Power7Rat'ings AC I np Voltage Ratings Current Ratings 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select 2 A maximum @ 120 VAC input; 1 A maximum @ 240 VAC input Power Supply Output 3 A maximum available for external loads Battery Charger Temperature compensated, capable of recharging batteries required for 90 hour standby and 10 minute alarm (contingent on auxiliary power load) Standby Current 100 mA; with lDCs fully loaded, tone-alert silenced, trouble LED on, charger off Alarm Current 264 mA + external loads; (2 zones in alarm & 2 internal relays, NACs and RACs on) Standard Circuit Ratings (NOTE: Total DC current = 3 A maximum; see NAC ratings for details) Initiating Device Circuits (lDCs) Supervisory Alarm Current Output Voltage Capacity 3 mA maximum; 3.3 kLl end-of-line resistor per circuit 75 mA maximum 28 VDC maximum Each IDC supports up to 30 detectors (smoke or electronic heat) and manual stations as required; wiring distance is limited to 50 92 maximum Application Special Purpose Monitoring Circuits For Dual Hazard Applications (SPMs) Supervisory Activated Output Voltage For Manual Release, Abort Switches, or Supervisory functions only; not for detectors; wiring distance is limited to 50 0 maximum Dual Hazard Application Abort Switches require a current limiting resistor of 1.2 k, 1 W, or an external Abort Supervision Module per SPM 6 mA; 3.3 kQ end-of-line resistor per circuit 75 mA maximum 28 VDC maximum Notification Appliance Alarm Current Circuits (NACs) Output Voltage Synchronized Strobe Operation Special Application appliance rating = 2 A maximum on a NAC NOTE: Special Application appliance rating = full 3 A power supply rating Regulated 24 DC appliance power = 1.5 A maximum on a circuit NOTE: Regulated 24 DC strobe load = 1.35 A maximum total for power supply Alarm = 26 VDC max.; supervisory = 29 VDC maximum; 10 kQ end-of-line resistor Requires NAC dedicated to strobe control with non-coded output; use an external Synch Module; up to 33 strobes can be synchronized per Z-10 Notification Appliance Reference Regulated 24 DC Appliances Power for other appliances listed to UL Standard 1971 or UL Standard 464; use associated external synchronization modules where required Output Current 2 A maximum per circuit Release Appliance Circuits (RACs) Output Voltage Activated = 26 VDC maximum; non-alarm = 29 VDC maximum; 10 W end-of-line resistor Auxiliary Power Output; for Special Application loads only Two outputs are available, continuous operation or resettable operation; combined output is 750 mA maximum; output voltage = 19.25 to 27 VDC Auxiliary Relay Outputs (Trouble, Aux Relay 2, Aux Relay 3) Contacts rated 2 A @ 30 VDC, 0.35 p.f., inductive, selectable as N.O. or N.C. by jumper Wiring Connections for Above and AC Input Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Auxiliary Module Ratings Class A Adapter Module 430531 Two circuits per module, rated same as circuits; not applicable to RACs (no additional current required) Auxiliary Relay Module 430529 Relay Type AC Ratings DC Ratings Four relays with two outputs per relay; individually selectable as N.O. or N.C. 7 A @ 120 VAC, resistive 5 A @ 30 VDC, 0.35 power factor, inductive I I; [i . [•] I Auxiliary Module Ratings (Continued) I Auxiliary Relay Module Module Current 430529 (Continued) Wiring 12 mA standby; 70 mA with all four relays energized; @ 24 VDC Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Coil Supervision Module - Construction Epoxy encapsulated Dimensions 1-3/8 in. W x 2-7/16 in. Lx 1-1/16 in. H (34 mm x 62 mm x 27 mm) Wiring 18 AWG (0.82 mm2) wire leads, color coded Coil Supervision Module Current Rating 2 A maximum; internally fused at 3 A, non-replaceable Environmental Ratings Operating Temperature Range 32 OF to 120 OF (0 °C to 49 °C) Operating Humidity Range up to 93% RH, non-condensing @ 100.4 OF (38 °C) maximum REFERENCE•INFORMATION, Part No. COMPATIBLE DETECTORS Type Component Sheet 430559 430562 LIFEalarm® Photoelectric Detector 2.80/o/ft Obscuration (Standard) LiFEalarm® Photoelectric Detector 3.50/./ft Obscuration T-2007153 430565 1350 F (57°C) Fixed Heat Detector T-2007159 430566 1 2000 F (93°C) Fixed with Rate-of-Rise Heat Detector T-2007159 NOTE: For proper detector bases, refer to Component Sheet T-2007153. A LISTED/APPROVED ACTUATOR OR DELUGE AND PREACTION AUTOMATIC WATER CONTROL VALVE; ONE IF 24 VDC (OR 2 IN SERIES IF 12 VDC) PER RAC ACTUATOR WIRING JUNCTION BOX Yel [ BIk: nj Blk ABORT SUPERVISION MODULE - --- -, COIL SUPERVISION MODULE 1 61 MAINTENANCE DISCONNECT SWITCH ABORT SWITCHES (AS REQUIRED) HLo 24 VDC FOR MAINTENANCE DISCONNECT STATUS INDICATOR (IF REQUIRED) j IIliiiI RAC2 I I I I OPTIONAL STROBE I I I I RAC I I SYNCHRONIZATION MODULE I I TYP I I ii IAI qTRORPnNIYNAr SPM1 I SPM2 IDC 1 TYPICAL HORN ONLY NAC MANUAL FIRE \I NAC 1 ALARM STATION COMPATIBLE , NAC 2 - I FIRE I 'FIRE DETECTION IDCS 2,3, AND 4 I DEVICES AUTOPULSE Z-10 SUPPRESSION RELEASE PANEL GENERAL WIRING NOTE: WIRING SHOWN IS FOR REFERENCE ONLY, REFER TO SPECIFIC INSTALLATION INSTRUCTIONS FOR DETAILED WIRING INFORMATION. 4 008203 PROGRAMMING MODES AND1SELECTION[CHOICES Sequence Select one of 13 Application Modes (numbered 1 through 13) Agent Release Single Hazard Cross-Zoned 1 Combined Release (RACs activate together) Either Zone 2 Dual Hazard Cross-Zoned 3 Independent Release (RACs are separate) Either Zone 4 1 Preaction/Deluge Single Hazard Cross-Zoned 5 Combined Release (RACs activate together) Either Zone 6 Dual Hazard Cross-Zoned 7 Independent Release (RACs are separate) Either Zone 8 Agent Release; Single Hazard Cross-Zoned 9 NYC Abort (not UL listed) Agent Release & Preaction; Single Hazard Cross-Zoned 10 Either Zone 11 RAC 2 provides Preaction Control; RAC 1 is Agent Release Control Agent Release, Bell/Horn/Strobe; Single Hazard Cross-Zoned 12 Either Zone 13 RAC 2 operates as NAC 3 for Stage 1 Bell Control (separate sound from release alarm) Sequence Programming Mode Description Description 2 Select Relay Operation for Application Modes 1-9 Select "Original" operation mode or "Enhanced mode 3 IDC and SPM Circuit Style Class B/Class A or Style C 4 Automatic Release Time Delay Selectable in 5 second increments from 0 to 60 seconds (default is 60 seconds) 5 RAC Cutout Timer No cutout, 45 seconds, or 1, 3, 3.5, 4, 5, 6, 7, 21, 25, 34, 44, or 64 minutes 6 Manual Release Time Delay 0, 5, 10, 15, 20, 25, or 30 seconds 7 Abort Release Time Delay UL Standard 864 listed Immediate or 10 seconds remaining Not UL Standard 864 listed IRI abort (cross-zoned systems only), NYC abort, or original release delay 8 NAC Coding (where selectable) Temporal pattern or 20 beats per minute (first cross-zone alarm) 9 Standard Operation NAC Operation Pre-Discharge Operation No inhibit or one minute inhibit selected as: both on until silence, NAC 1 on until reset and NAC 2 on until silence, or both on until reset; NOTE: For clean agent release, a pre-discharge NAC must be configured to warn of impending discharge, the release timer selects the duration of the pre-discharged signal 10 Supervisory Latching Latching or non-latching 11 Supervisory Notification LED and tone-alert only, or with: NAC 2 also on; Aux Relay 3 also on; or both NAC 2 and Aux Relay 3 also on 0 0 0,111 OPERATOR PANEL FUNCTIONIREFERENCE r LABEL INSERT SELECTABLE FOR PREACTION/DELUGE, AGENT RELEASE, I OR COMBINATION AGENT RELEASE/PREACTION DELUGE, UL OR ULC VERSIONS (UL AGENT RELEASE VERSION SHOWN FOR REFERENCE Oliarm I 1 Zonel I Q: Lirouble Zone 5 Trouble) 0 r1Alarm fl 1 Manual Release 0 Zone 21 jrouble J one 6 Trouble) 0 NAC 1 Trouble 0 NAC 2 Troublej 0 r RAC 1 Trouble") 0 L RAC 2 Trouble j 0 - - Agent Released Earth Fault Abort Active Relay Disconnect JLACKJ ALARM SILENCE RUN MODE: LEDs PROVIDE I ALARM (RED) AND TROUBLE (YELLOW) STATUS PER IDC 7 I ZONE; ZONE 4 YELLOW LED 7 I INDICATES SUPERVISORY ( I STATUS IF STILL FLASHING I AFTER ACK \ I PROGRAM MODE: TOP TEN \ LEDs INDICATE I PROGRAMMING MODE CATEGORY ALARM SILENCED YELLOW LED INDICATES THAT AUDIBLE NOTIFICATION I APPLIANCES ARE SILENCED PRIOR TO SYSTEM RESET SUPERVISORY AND SYSTEM TROUBLE YELLOW LEDs; FOR UL SYSTEMS, INDICATION OF DISABLED OR DISCONNECTED RAC AC POWER GREEN LED IS ON WITH NORMAL POWER STATUS 0 'Alarm I Zone 31 rouble ) larm Zone 4k °ZT, rouble 0 'Alarm Silenced 0 Supervisory Q stem Trouble - - 0 AC Power) SYSTEM RESET RUN MODE: RED LEDs I INDICATE MANUAL RELEASE ACTIVATED (FOR AGENT RELEASE APPLICATIONS); YELLOW LEDs INDICATE I TROUBLE FOR SPMs (ZONES I 5 and 6), NACs, and RACs, FOR RACa, YELLOW LED I INDICATES SUPERVISORY IF I STILL FLASHING AFTER ACK PROGRAM MODE: TOP EIGHT LEDs PROVIDE PROGRAMMING SELECTION --I AGENT RELEASED RED LED INDICATE RACs ARE ACTIVATED EARTH FAULT YELLOW LED INDICATES PRESENCE OF AN EARTH FAULT ABORT ACTIVE YELLOW LED TRACKS STATE OF ABORT SWITCH RELAY DISCONNECT YELLOW LED INDICATES THAT EXPANSION RELAYS HAVE BEEN DISABLED FOR SERVICE 6 ACK ACKNOWLEDGES STATUS DURING RUN MODE AND ACCEPTS SELECTION DURING PROGRAM MODE; PRESS AND HOLD FOR 5 SECONDS TO PERFORM LAMP TEST ALARM SILENCE SILENCES AUDIBLE ALARMS \ 006552 SYSTEM RESET RESTORES THE SYSTEM TO NORMAL DURING RUN MODE AND TOGGLES THE SELECTION DURING PROGRAM MODE Solenoid valves are connected as 2-wire, Class B notification/ releasing circuits with only one 24 VDC solenoid valve per circuit (or two, 12 VDC solenoids in series if applicable) to ensure supervi- sion. Coil Supervision Module, Part No. 430687, must be wired electri- cally before the solenoid valve and located in the solenoid valve wiring junction box. For FM Approved Deluge and Preaction Sprinkler operation, initiat- ing device circuits must be Class A, wired to Listed/Approved devices. Power supply loading and wiring distances must be per Installation, Programming, and Operating Instructions, Part No. 430545. For FM Approved Deluge and Preaction Sprinkler Systems, battery standby capacity must be a minimum of 90 hours with 10 minutes of alarm. For FM Approved Automatic Extinguishing Release, battery standby must be a minimum of 24 hours with 5 minutes of alarm. Battery standby must be selected for a minimum voltage of 23 VDC to ensure proper valve operation. Maintenance Switch, Part No. 433936 or 433937, are required to allow the system to be tested or serviced. For FM Approved Deluge and Preaction Sprinkler operation, the specified compatible Automatic Water Control Valves must be used. For UL Listed and FM Approved Automatic Extinguishing Release, solenoid valves must be electrically compatible. ' 11. Abort Switch, Part No. 433940, is available when abort operation is required. When used, wire on Special Purpose Monitoring Circuits (SPMs) as Class A or B, the same as required for other initiating devices. 12. Manual Release Stations are used for direct activation of the release solenoids with the appropriate time delay implemented by the fire alarm control panel. UL Listed: S4935 FM Approved: J.I.3012391 CSFM: 7165-0595:113 MEA (NYC): 49-03-E Auxiliary Relay Module, Part No. 430529. Four relays per module are available as required. Dual hazard applications will require two modules for auxiliary relay operation. Each relay module has a manual discon- nect switch that controls relays 2 through 4 (Trouble Relay is not controlled). Relay outputs are required to be connected to 15 A maximum circuit breaker. Operation is per the following actions: Relay 1 activates on any trouble associated with its hazard Relay 2 activates on any alarm associated with its hazard Relay 3 activates for pressure switch as required per application or actu- ates with second zone for cross-zoned systems (hazard specific) Relay 4 activates when the hazard specific RAC activates Dual Circuit Class A Adapter Module, Part No. 430531. This module converts two Class B circuits to Class A operation. It consumes no addi- tional current and is compatible with IDCs, SPMs, and NACs. Up to four modules may be mounted within the AUTOPULSE Z-10 cabinet. Maintenance Switch. Proper service of release appliance circuits requires the ability to securely disconnect the release circuit during installation and maintenance. Maintenance switches are controlled by keyswitch and initiate a supervisory condition when in disconnect/disable position. Models with lamp are on a double-gang plate and are powered from separate 24 VDC wiring. Mounting is on stainless steel plates and models are available as either surface or flush mount (see drawing below). Maintenance switches, one per RAC, are required per NFPA 72, the National Fire Alarm Code, to allow the system to be tested or serviced without actuating the fire suppression systems. Their use may not be allowed in some jurisdictions; always confirm local requirements. When used, maintenance switches are required to ensure that operation initi- P. a supervisory condition. NORMAL OI DISABLE FIRE SUPPRESSION DISCONNECT! DISABLE £t1tPutsa Maintenance Switch 006549 Abort Switch. For manual abort requests, these abort switches are available with or without a built-in 1.2 kQ, 1 W resistor and are mounted on single-gang stainless steel plates. Abort switches are connected to the SPM inputs per system requirements. Activity abort occurs while the switch is pushed and continues after releasing the switch for the selected Abort Release Time Delay (see drawing below). FIRE SUPPRESSION SYSTEM ABORT 11 tD kPuIs Abort Switch 006550 - BOX WIDTH 14-5/8 IN (372 mm) TYPICAL CONDUIT ENTRY AREA (CUT HOLES AS REQUIRED) II (TOP AND SIDE VIEWS ARE SHOWN WITH DOOR INSTALLED) DOOR THICKNESS - 5/8 IN (16 mm) BOX DEPTH 4-1/4 IN (lo8mñi) 16 IN (483 mm) 006555 (FRONT VIEW MODULE PLACEMENT REFERENCE SHOWING NOTE: FOR SEMI-FLUSH MOUNTING, CABINET MOUNTING HOLE DIMENSIONS, OPTIONAL CLASS A ADAPTER MUST EXTEND 1-1/2 IN (38 mm) MODULES, AND OPTIONAL RELAY MODULES) MINIMUM FROM WALL SURFACE NOTE: A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND TRANSIENT PROTECTION DEVICES. THIS CONNECTION SHALL BE MADE TO AN APPROVED, DEDICATED EARTH CONNECTION PER NFPA 70, ARTICLE 250, AND NFPA 780. Part No. Description 430525 AUTOPULSE Z-10 FACP, 120/240 VAC NOTE: Proper operation of release control systems requires that the system design, installation, and maintenance be performed correctly and in accordance with all applicable local and national codes, and equipment manufacturer's instructions. No liability for total system operation is assumed or implied. ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. Ansul Incorporated 715-735-7411 Copyright 8)2008 Ansul Incorporated Is.IANsuLI LI Marinette, WI 54143-2542 www.ansul.com Form No. F-2007055-1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0595:0113 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: ANSUL FIRE PROTECTION, 1 Stanton Street, Marinette, WI 54143-2542 Contact: Jim Engman (715) 735-7411 Fax (715) 732-3634 Email: jengman@tycoint.com DESIGN: Model Autopulse Z-10 (430525) fire alarm control unit. Power limited. Local or releasing service, automatic, manual, waterilow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/220 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition*. XLF: 7165-0026:0314 *Updated 02-08-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational cfr requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 3O,2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ANSUL® .i UI' 11 • IN 'I II 1ri.-rAv'. I II i I i U II i• I .$• i ir.rii i U UI II 17311;1111 I NW . i!U•IUNluilUUUINUN...N...........IN, I 1 N UUUL ILIA...A Detection and Control Components Electric Manual Pull Station Features UL Listed/FM Approved Approved for ADA Dual action Die-cast metal construction Terminal block Optional auxiliary contacts Flush mounts on single gang box Surface mount back box available Weatherproof back box available High-gloss red enamel finish Customized labels Keyed to match AUTOPULSE® control units Applications The Electric Manual Pull Station is a cost-effective, feature- packed, non-coded manual fire alarm pull station. It was designed to meet multiple applications with the installer and end-user in mind. The pull station provides the AUTOPULSE control panels with an alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the pull station simple to install, maintain, and operate. Description The Electric Manual Pull Station is a high-quality, die-cast metal, dual action fire alarm pull station available with a SPST, DPST or DPDT switch with terminal strip connections. The contacts are rated for 1 Amp at 30 VDC. Gold plating on the contacts avoid the risk of corrosion. All models in the series have been tested by UL for compliance to the latest requirements of the American with Disabilities Act (ADA). The Electric Manual Pull Station is operated by pushing in the top bar and pulling the handle on the front of the station as far down as it will go. At this point, the handle locks into place and is easily visible from up to 50 ft. (15 m). Opening the station with the key, placing the handle in the normal upright position and re-locking the station resets the pull station. The addressable ready pull station comes with a bracket on the back for securing the FMM-101 Mini Monitor Module, Part No. 428098 (sold separately). The terminal block pro- vides clamping plates for easy connection to the SLC loop and N.O. switch contacts. An end-of-line resistor for the AUTOPULSE IQ-301 and AUTOPULSE I0-396X is factory installed across the switch contacts. STANDARD PULL STATION 7/8 IN. (22 mm) WEATHERPROOF PULL STATION PUS 1 411/1 6 IN. (119 m) /4 IN. /4 IN. (83 mm) -(83mm) 004648a PULL STATION (95mm 33/4 IN. ) 006753 2-1-06 3-32 WIRING - SPST PULL STATION TO AUTOPULSE CONTROL UNIT TO NEXT DEVICE 004928 EOLR WIRING - DPST PULL STATION TOAUTOPULSE TONEX CONTROL UNIT DEVICE WIRING - EXPLOSION PROOF PULL STATION 1 --- L L I I I,II tLfl _ Jz Jz : TOAUTOPULSE TO NEXT EOLR CONTROL UNIT DEVICE 004930 t4929 TECHNICAL INFORMATION Conventional Switch Ratings . 1 A@ 30 VDC 1 A@ 120 VAC Switch Type: .......................... SPST or DPST Terminal Size: ......................... Up to 14 AWG Color ...............Red with raised white letters, white PUSH/PULL HANDLES with raised red letters Weather Proof with Weather Proof Back Box ... NEMA 3R Explosion-proof Switch Ratings: ...................... 1 A @ 30 VDC, 10A@ 120 VAC Switch Type: ................................DPDT Terminal Size: ........................ Upto 14AWG Humidity: .............90% Relative at 100 OF (37.7 °F) Explosion Hazard Classifications: . Class I Groups B, C, D; Class II Groups E, F, G; Class III Weatherproof Classifications- ...........NEMA Type 4X Other Classifications- ................UL Marine Listing Conduit Fittings- .................................2 Conduit Fitting Size: .................. 3/4 in. - 14 NPT Color ..............Red with raised white letters, white PUSH/PULL handles with raised red letters LISTINGS AND APPROVALS* UL........................................S5654 UL (Explosion-proof Model) .................E 192508 ULC.......................................Listed Factory Mutual ...........................Approved California State Fire Marshal (CSFM) .....7150-1408:107 MEA....................................382-94-E Listings and Approvals are under Signal Communications Corporation ORDERING INFORMATION Shipping Part Weight Description ik thg 428655 Manual Pull Station, SPST 1 (0.45) 428656 Manual Pull Station, DPST 1 (0.45) 428657 Explosion Proof Manual Pull Station 1 (0.45) 428658 Manual Pull Station, 1 (0.45) Addressable Ready 428659 Weatherproof Back Box 1 (0.45) 428660 Surface Back Box 1 (0.45) 428661 Break Rod 1 (0.45) 418336 Key 1 (0.45) 428654 Label Packet 1 (0.45) WIRING -ADDRESSABLE READY PULL STATION FMM-1O1 BLACK•..1p ' RED VIOLET YELLOW TOAUTOPULSE 1 0 0 191 EOLR I0-301 or I0-396X - ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINEUE, WI 54143-2542 715-735-7411 Form No. F-2001032-1 102006 Ansul Incorporated 00493t CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1408:0107 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: SIGNAL COMMUNICATIONS CORP4 Wheeling aye, Woburn, MA 01801 Contact: Nadim Farhat (781) 933-0998 Fax (781) 933-5019 Email: nfarat@sigcom.com DESIGN: Models SG-32AX, SG-32B, SG-32P5, SG-325, SG-32CX, SG-33B, SG-33S, SG-33AX, SG-3413, SG-345, SG-34AX, and SG-34P5, SG-365, SG-36AX, SG-36CX, SG-42CX, SG-425, SG-44CX and SG-445 noncoded manual pull stations followed by H (hex lock) or K (key lock), followed by suffix 1 (push bar) or 2 (no push bar) and SGB-325 indoor back box. Models SG-32P5 and SG-33PS do not have suffix -1 or -2. Suitable for outdoor use when installed with Models SGB-32C and SGB-32CD back boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC, 125 VAC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. *Updated 07-07-09 fm ,.,. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ANSUL® 'NO I 'No NUMME ii rruI ii• U.0 AkuIIUIIitI7U Al •i II I 'df 1 • k i uil.I.IlI1I.I,I •I.l • U 11 .i. UL II I.AL.A• Detection and Control Components Abort Switch Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Abort Switch is used to momentarily interrupt the release circuit signal when the control unit is in the alarm condition. As long as the abort pushbutton is held in, the fire suppres- sion system will not release. (Note: When the control unit is programmed for IRI compliance, the abort will not be effec- tive after pre-discharge.) When the pushbutton is released, the release circuit is activated (unless the control unit has been reset to the non-alarm condition). Description The Abort Switch assembly consists of a momentary- contact pushbutton switch, normally-open contact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assemblies include a single-gang weather-proof box with three 1/2 in. I.P.S. threaded conduit outlets and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break or 6 amp continuous carry. Listings and Approvals The switch is UL listed (S3623) when installed in the surface- mount box (with gasket) that is provided with the surface- mount assembly. MOUNTING DIMENSIONS TYPICAL WIRING DIAGRAMS ABORT SWITCH (SERIES) EOL RESISTOR I G(+) ZC I----, CONTROL UNIT ABORT CIRCUIT N ABORT L.C.TERMINALS* SWITCH ABORT SWITCH (PARALLEL) EOL RESISTOR / 4 I Ø(+) I I I (OH N.O.ABORT CONTROL UNIT ABORT CIRCUIT SWITCH TERMINALS*_ * SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. Ordering Information Shipping Weight Part No. Description lb. (kg) 76494 Abort Switch, Surface-Mount 1.0 (0.45) 76495 Abort Switch, Flush-Mount 1.0 (0.45) 76485 Extra Contact Block, N.C. 0.25 (0.11) 76486 Extra Contact Block, N.O. 0.25 (0.11) ANSUL and AUTOPULSE are registered trademarks. .__2 7/8 IN. (73 mm) 0 ANSUL FIRE SUPPRESSION SYSTEM ABORT O 45/BIN. (117 mm) PUSH AND HOLD 0 SURFACE-MOUNT cia FLUSH-MOUNT 2 3/8 IN. (60 mm) 3-34 ANSUL INCORPORATED, ONE STANTON STREET, MAIRINETTE, WI 54143-2542 715-735-7411 Form No. F-95111 5)1995 Ansul Incorporated Litho in U.S.A. rii..uii.i...uu.uiuuuuunor 9-1111111uuuuuuu.i.ui- I•.Y i& I.. 'I I., U IWZIr1.-rL1r'. i • - 1111W 1 mliii i. I - I U ui Iruril .'i.-'u• -- Al UI II I ir I il ..I UI •_ II UuuL II I.AL. JUl U. •..UIUUUUU 14 LI... U•.• Key Maintenance Switch Ordering Information Part No. Description 76498 Maintenance Switch, Surface-Mount 76499 Maintenance Switch, Flush-Mount 76485 Extra Contact Block, N.C. 76486 Extra Contact Block, N.O. - 78179 Spare Key 470273 Extender-Back Box Shipping Weight lb. (kg) 2.0 2.0 0.25 0.25 0.25 0.25 4 11116 IN. (119 mm) 0 0 NORMAL COCKOU D ANSUL FIRE SUPPRESSION SYSTEM ABORT 0 0 4 5/8 IN. (117 mm) FLUSH-MOUNT 23/4 IN. .4 —4- (70 mm) SURFACE-MOUNT ANSUL® Detection and Control Components Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Key Maintenance Switch is used to interrupt the release circuit signal to the fire suppression system. It is key-operat- ed to allow authorized personnel to deactivate the release circuit during service or maintenance. An indicator lamp, located on the switch plate, will light when the switch is in the "lock-out" mode to serve as a reminder that the release cir- cuit has been disconnected. Description The Key Maintenance Switch assembly consists of a key- operated switch, 24 VDC indicator lamp, normally-open con- tact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assem- blies include a double-gang weather-proof box and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break or 6 amp continuous carry. Listings and Approvals The switch is UL listed when installed in the surface-mount box (with gasket) that is provided with the surface-mount assembly. TYPICAL WIRING DIAGRAM KEY-OPERATED CONTROL UNIT 24 VDC LOCK-OUT SWITCH RELEASE CIRCUIT ACTUATOR TERMINALS* N.C. (—) 4_NO 1 POLAR1Y IS SHOWN IN ALARM 24 VOC POWE ON SOURCE LNffI_ 24 VDC INDICATOR LAMP * SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. MOUNTING DIMENSIONS ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. 3-33 ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-95110-1 @2003 Ansul Incorporated Litho in U.S.A. ANSUL® ..I'. vrIu-In rLIr-u u irarii 111W s I Al •I II I 'F ál .0 'U 111 liii t.t I i.u.l UP UI •i._ ii .JU i •• . - U iU•UL II i'IL.AU ME MEMOS Detection and Control Components LIFEalarm® Photoelectric Smoke Detectors For Two-Wire Bases Features LIFEalarm@ Photoelectric smoke detector with on-board sensitivity drift compensation* Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: Part No. 430559 (Part No. 430695 ULC), Standard Sensitivity, nominal 2.8%/ft obscuration Part No. 430562, Special Application Sensitivity, nominal 3.5%/ft obscuration Available base options: Bases for 2-wire operation Auxiliary alarm relay output Optional remote alarm indicating LED Description LIFEalarm photoelectric detectors provide many of the proven analog sensing features for applications where detectors are connected to conventional 2-wire initiating device circuits (lDCs). Each detector has an on-board micro- processor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. LlFEalarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high perfor- mance smoke capture ability. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. * LiFEalarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468: 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573. 006564 LlFEalarm Photoelectric Detector Mounted in Base Listings and Approvals UL Listed ULC Listed FM Approved CSFM (Pending) MEA (NYC) (Pending) Specifications Voltage 15 to 32 VDC, from Control Panel IDC Standby Current 100 pA@ 24 VDC Alarm Current, Up to 86 mA maximum, exact 2-Wire Operation current is determined by alarm current limiting of connected IDC Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/mm (0-610 rn/mm) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 150 to 122° F (-9° to + 50° C) Humidity Range 10% to 95% RH from 320 to 122° F (00 to 50° C) non-condensing Color Frost White Dimensions 4 7/8 in. Dia. x 1 7/8 in. H, mounted in base (124 mm x 48 mm) Smoke Detector Features Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accu- mulation of dust and dirt. With analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the proba- bility of false or nuisance alarms caused by shifts in sensitiv- ity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. Application Reference Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. For further detailed installation information, refer to Detectors, Sensors, and Bases Application Manual, Part No. 431424. Sensitivity Selection. The standard sensitivity detector, Part No. 430559, is recommended for most applications. When a special application for a reduced sensitivity detector is required, Part No. 430562 should be considered. Consult Ansul for assistance in determining the proper selection. Product Selection Smoke Detectors Part No. Description Nominal Sensitivity Compatibility 430559 and 430695 (ULC) LlFEalarm Photoelectric Detector 2.8%/ft (standard) Compatible with detector bases: Part Nos. 430567 and 430569 430562 3.5%/ft Compatible Bases Part No. Description Details 430567 2-Wire Base with connections for IDC and LED connections are screw terminals for 430701 (ULC) Remote Alarm LED Indicator in/out wiring, 18 to 14AWG 430569 2-Wire Base with Auxiliary Alarm Relay Relay Ratings, Dual Form C, For Suppressed Loads: 430702 (ULC) & connections for Remote LED Indicator Power limited, I A @ 28 VDC NOTE: Must be connected as the only device Non-power limited, 1/2 A @ 120 VAC on the IDC to ensure relay operation. Wiring Connections (In/Out where required): Relay contacts and IDC (-), color coded 18AWG leads 430570 2-Wire Base with Remote LED Indicator 430703 (ULC) IDC (+) and LED wiring, screw terminals for 18 to 14 AWG 430572 Remote LED Alarm Indicator 430704 (ULC) Detector Accessories Part No. Description Details 430646 Adapter Plate Required for mounting to 4 in. square box, fits 4 in. octagonal box May be used when retrofitting existing bases Compatible with Part No. 430567 and Part No. 430569 detector bases 430572 Remote LED Indicator Mounted on single gang stainless steel plate Detector Status LED Indications LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal, sensitivity is within compensation range None LED pulses quickly, 6 times in 3 seconds, then turns ON Alarm is initiated More sensitive, out of normal compensation range Cleaning or other service is required LED pulses slowly, 4 times in 8 seconds, then turns ON Alarm is initiated Less sensitive, out of normal compensation range Does not initiate Alarm Detector is malfunctioning Service is required * Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual, Part No. 431424, for further test and maintenance information. Dimensions and Reference Information 1/4 IN. 6 3/8 IN. (6.4 mm) (162 mm) OPTIONAL ADAPTER PLATE, PART NO. 430646 (REQUIRED FOR 4 IN. SQUARE BOX) 4 7/8 IN. (124 mm) •1 BASE HEIGHT 11/16 IN. (17 mm) 1 7/8 IN. (48 mm) I 006565 (WITH CLEAR LENS) PART NO. 430559 AND PART NO. 430562 DIMENSIONS MOUNTED ON BASE ALARM 0 006567 REMOTE RED LED INDICATOR, PART NO. 430572 (NOT TO SCALE) Mounting Information ELECTRICAL BOX REQUIREMENTS: WITHOUT RELAY (BASE, PART NO. 430567): 4 IN. OCTAGONAL OR 4 IN. SQUARE, 1 1/2 IN. DEEP SINGLE GANG, 2 IN. DEEP WITH RELAY (BASE, PART NO. 430569): 4 IN. OCTAGONAL, 11/2 IN. DEEP, WITH 1 1/2 IN. EXTENSION RING 4 IN. SQUARE, 11/2 IN. DEEP, WITH 11/2 IN. EXTENSION RING SURFACE MOUNT RFFERFPJCF 4 IN. (102 SQUARE[ 4 IN. (102 mm) OCTAGONAL BOX 11/2 IN. (38 mm) FLUSH MOUNT REFERENCE, MOUNT EVEN WITH FINAL MINIMUM BOX DEPTH SURFACE, OR WITH UP TO 1/4 IN. (6.4 mm) MAXIMUM RECESS ADAPTER PLATE, PART NO. 430646, REQUIRED FOR MOUNTING TO SURFACE MOUNTED BOXES AND TO 4 IN. SQUARE FLUSH MOUNT BOXES PART NO. 430569 INCLUDES A RELAY MODULE THAT MOUNTS IN BASE ELECTRICAL BOX SMOKE DETECTOR BASES, PART NOS. 430567 AND 430569 006566 SMOKE DETECTOR, PART NOS. 430559 AND 430562 ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2042 710-736-7411 Form No. F-2002159 (02003 Ansul Incorporated Litho in U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1597:0105 Page 1 of 1 CATEGORY: 7272 -- PHOTOELECTRIC SMOKE DETECTOR LISTEE: TEPG - US, 91 Technology Dr, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 430559, 430560, 430562, *T360..9001 and *T360..9002 photoelectric type smoke detectors. Models 430560 and *T360..9002 employ an integral 1350F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed system description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, *electricallair velocity rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with separately listed compatible fire alarm control units. Intended for use with separately listed Models 430567, 430569, 430570, *T3609902, *9903 and *..9904 detector bases (CSFM Listing No. 7300-1597:107). For indoor use only. XLF: 7272-0026:0219 *Rev. 05-11-04 , This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational Zc' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1597:0107 Page 1 of I CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: TEPG - US, 91 Technology Dr, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 - Email: pmatterntycoint.com DESIGN: Model 430567, 430569, 430570, *T360..9901 *T360..9902 *T360..9903 and *T360..9904 detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0026:0222 *Rev. 09-25-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed g\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division INOTE BY JAM FIRE: I THE ELECTRONIC SOUNDER WITH STROBE IS ALSO I THE WHEELOCK, MT SERIES STROBE. THE I Detection and Control Components IWHEELOCK DATA SHEET HAS THE CURRENT DRAW I INFORMATION. 5-24-10 IL1IIiIr Acle Ill-I-Il I li-ill I III (-1-I I I.i!.jj_. Features Approvals include: UL, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) (Pending for MTWP) ADA/NFPNUFC/ANSI compliant Meets OSHA 29 Part 1910.165 Strobes produce one flash per second over the regulated voltage range (MTWP produces 30-62 flashes per minute) Synchronize with Wheelock SM One-alarm appliance with eight selectable signals Two installer-selectable sound output levels cover range of 76-94 dBA reverberant Fast installation with IN/OUT screw terminals using #12 to #18AWG wire Available as FIRE or AGENT units Description The electronic sounder with strobe provides either indepen- dent or simultaneous audible and visual alarm indication. The electronic sounder is UL listed for primary or secondary sig- naling and the strobe is suitable for primary signaling in pub- lic mode for life safety applications. The strobe complies with the Americans with Disabilities Act (ADA) and the demanding requirements of the UL 1971 Standard for the Hearing Impaired. The MT-24MCW 15, 30, 75, or 110 multi-candela strobe meets the light intensity requirements for the space being protected. One of eight different warning tones can be selected during installation by arranging four programming switches. This provides for superior sound penetration for various ambient and wall conditions with two field selectable sound output lev- els. The MT model mounts directly to a 4 in. (102 mm) square back box with an optional SFP semi-flush plate. The MTWP model mounts to a 5.25 in. (133 mm) square lOB weatherproof back box. Screw terminations provide secure attachment for field wiring of up to 12 AWG wire size. Technical Information Input Terminals ......................... 18to12AWG Size.....................5.125 in. x 5.125 in. x 4.375 in. (130 mm x 130 mm x 111 mm) Weight ................................0.9 lb. (0.4 kg) Color.........................................Red Operating Temperature: MT Models .............32 OF to 120 °F(0°Cto49 °C) MTWP Model........-31 OF to 150 OF (-35 °C to 66 °C) Electronic Sounder with Strobe (10-3189 IQ-636X-2, 542R, 542D9 Z-10) Mounting: MT Surface ............. ........ ..4 in. x 4 in. x 1.5 in. (102 mm x 102 mm x 38 mm) standard back box MT Semi-flush ...................4 in. x 4 in. x 1.5 in. (102 mm x 102 mm x 38 mm) standard back box with SFP mounting plate (ordered separately) MTWP Weather-Proof ........5.25 in. x 5.25 in. x 2.625 in. (133 mm x 133 mm x 67 mm) weatherproof lOB back box (ordered separately) Voltage Range ........................... 16-33 VDC Input Voltage ................................24 VDC DIMENSIONS 4 3/8 IN. /111 nn,\ 2 3/41r (70 mrr MOUNTING WITH OPTIONAL SEMI-FLUSH PLATE STANDARD BACK BOX SFP SEMI- FLUSH PLATE ELECTRONIC ) >Vi SOUNDER WITH STROBE KLØ 006145 ro TONE SELECTION SWITCHES MMING 006166 3-6 Technical Information (Continued) dBA AND CURRENT RATINGS FOR MULTITONE AUDIBLE PORTION RMS Current (amps) dBA @ 10 ft dBA @ 10 ft (UL Reverberant) (Anechoic) 24 VDC 24 VDC 24 VDC Hi Output @ 24 UL VDC max* STD Output @ 24 UL VDC max* Hi Output STD Output Hi Output STD Output Horn 0.074 0.108 0.033 0.044 92 87 99 93 Bell 0.040 0.053 0.018 0.024 86 80 92 87 March Time Horn 0.067 0.104 0.033 0.038 89 84 99 93 Code-3 Horn 0.069 0.091 0.026 0.035 88 83 99 93 Code-3 Tone 0.061 0.075 0.026 0.035 85 80 95 90 Slow Whoop 0.069 0.098 0.028 0.037 90 89 98 93 Siren 0.080 0.104 0.027 0.036 89 84 98 93 HI/LO 0.044 0.057 0.020 0.026 86 81 93 88 NOTE: If the strobe and audible operate on the same circuit, add the strobe current from Table 2 to the audible current from Table 1. * RMS Current ratings are per UL average RMS method. UL max Current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes, the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles, the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. WIRING DIAGRAM + FROM PRECEDING TO NEXT RED APPLIANCE APPLIANCE I FACP OR EOLR BLACK I F - + - I + - I 006150 STROBE AUDIBLE Listings and Approvals* UL..........................................E5946 Factory Mutual .............................Approved California State Fire Marshal (CSFM) MT Models .......................... 7125-0785:155 MTWP Models.......................7135-0785:156 MEA......................................151-92-E *Listings and Approvals are under Wheelock Inc. Alarm Tones Tone Alarm Tones Pattern Description Horn Broadband Horn (Continuous) Bell 1560 Hz Modulated (0.07 sec ON/Repeat) March Time Horn Horn (0.25 sec ON/0.25 sec OFF! Repeat) Code-3 Horn Horn (ANSI S3.41 Temporal Pattern) Code-3 Tone 500 Hz (ANSI S3.41 Temporal Pattern) Slow Whoop 500-1200 Hz Sweep (4.0 sec ON/ 0.5 sec OFF/Repeat) Siren 600-1200 Hz Sweep (1.0 sec ON/Repeat) HI/LO 1000/800 Hz (0.25 sec ON/Alternate) Ordering Information Part No. Model Description Shipping Weight lb (kg) 433356 MT-24MCW-FR Strobe, Multi- 2 (0.9) Candela w!Sounder (FIRE) 433357 MT-24MCW-AR Strobe, Multi- 2 (0.9) Candela w/Sounder (AGENT) 431526 MTWP-2475W-FR Sounder/75cd*, 2 (0.9) Weatherproof w!Sounder (FIRE) 429701 SFP Semi-Flush Plate 0.5 (0.2) 429700 lOB Surface Back Box 2 (0.9) 429702 ISP Adapter 0.5 (0.2) * Rated 75cd at -31 OF (-35 °C). Rated 180 cd at 77°F (25 °C) AUTOPULSE is a trademark of Tyco International (US), Inc. or its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, WI 54143-2542 Form No. T-2007136 Copyright ©2007 Tyco International (US), Notification Series MT and MT Strobe Multitone Electronic Appliances SERIES MT STROBE MT4-115-WH SERIES MT-12124 Description: The Wheelock Series MT and MT Strobe Multitone electronic appliances offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code-3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. The Code-3 Horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe appliances, one alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panel incorporating the Wheelock Patented Sync Protocol. The MT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UFC and ULStandard 1971 as well as meeting ADA requirements concerning photosensitive epilepsy. Each MT and MT Strobe appliance has two installer selective sound output levels: STANDARD dBA and HIGH dBA. Non-strobe versions provide selectable voltage capability in one unit, 12VDC or 24VDC. Strobe versions are specific for either 12VDC or 24VDC and all models may be used with filtered or unfiltered (full-wave- rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input. The Series MT Multitone Strobe appliances are UL Listed for indoor wall mount applications under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Audible Signaling Appliances. Features: Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information Designed to meet or exceed ADAINFPNUFC/ANSI Standards and Accessibility Guidelines Complies with OSHA 29, Part 1910.165 Series MT appliances have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of the (8) eight audible sounds MT Strobe models are available with Wheelock patented MCW Multi-Candela strobes with field selectable candela settings at 15/30/75/110cd or with single candela 1575cd strobes. Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide- Listed voltage range, filtered (DC) and FWR No additional trimplate required for flush mounting For Weatherproof MTWP See Data Sheet S9004 MEA APPROVED E5946 151-92-E 7135-0785:118 (MT4) 7125-0785:155 (MT) NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" (16-33v for 24VDC units and 8-17.5v for 12VDC units). Regulated Voltage Range is the newest terminology used by UL to identify the listed voltage range. All candela ratings represent minimum effective Multitone Strobe intensity based on UL Standard 1971. MT Strobe models are UL Standard 1971 Listed for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ±2%. The MT-1 2/24, MTWP and MT4 models and listed for outdoor use at -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95% (See Data Sheet S9004 or Installation Instruction Sheet P84150 for more detail on MTWP). MTWP and MT4 strobes are listed under UL 1638. MT Audible is UL Standard 464 Listed. Alarm Tones TONE ALARM TONES PATTERN DESCRIPTION HORN BROADBAND HORN (Continuous) BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat) MARCH TIME HORN HORN (0.25 sec. ON/0.25 sec. OFF/Repeat CODE-3 HORN HORN (ANSI S3.41 Temporal Pattern) CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) SIREN 600-1200 Hz SWEEP (1.0 sec. ON/Repeat) HI/LO 1 1000/800 Hz (0.25 sec. ON/Alternate) Table 1: dBA and Current Ratings for Multitone Audible Portion RMS Current (amps) dBA @ l Oft (UL Reverberant) 24 VDC 12 VDC 120 VAC 24 VDC 12 VDC 120 VAC HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output @ 24 VDC UL max* @ 24 VDC UL max* @ 24 VDC UL max* @ 24 VDC UL max" UL max" UL max* Horn 0.074 0.108 0.033 0.044 0.145 0.176 0.023 0.034 0.050 0.042 92 87 90 77 85 82 Bell 0.040 0.053 0.018 0.024 0.077 0.095 0.014 0.020 0.041 0.039 86 80 85 69 82 75 March Time Horn 0.067 0.104 0.033 0.038 0.109 0.142 0.023 0.034 0.050 0.040 89 84 89 74 85 79 Code-3 Horn 0.069 0.091 0.026 0.035 0.100 0.142 0.023 0.034 0.050 0.042 88 83 88 73 82 75 Code-3 Tone 0.061 0.075 0.026 0.035 0.088 0.105 0.015 0.021 0.042 0.040 85 80 84 70 79 75 Slow Whoop 0.069 0.098 0.028 0.037 0.100 0.142 0.025 0.035 0.050 0.042 90 89 89 75 85 82 Siren 0.080 0.104 0.027 0.036 0.122 0.152 0.021 0.030 0.045 0.041 89 84 89 75 85 82 HI/LO 0.044 0.057 0.020 0.026 0.089 0.114 0.018 0.026 0.042 0.039 86 81 86 71 82 79 Table 2: Strobe Current Ratings RMS Current (amps) Model MT-121575 MT-241575 MTWP-2475 MT-24MCW Candela 1575cd 1575cd 180cd 15cd 30cd 75cd 110cd @ 24VDC 0.152 0.060 0.094 0.041 0.063 0.109 0.140 UL max* 0.255 0.090 0.138 0.060 0.092 0.165 0.220 Note: If the strobe and audible operate on the same circuit, add the strobe current from Table 2 to the audible current from Table 1. * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams (for all models) MT SIGNAL PROMO PROCEDURES +0 To MEETS 000LDEJICO,D REPL100CE OR" EEL RU SM/DEMO _{3 PS-12/2 SEPT PS-12/21-8000 POWERS SUPPLIES rO FACE] SIGNALO AUDIBLE SIGNAL AND STROBE OPERATE INDEPENDENTLY RRECEDINUII AUDIBLE IOU —DO PUll! PURER PS-l~I!4-8MPO OR F-PO STROBES AUDIBLED IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. _jXIjMSLE ORE PROMO LI + TO NEXTO PRECEDING APPLIANCE +EU APPLIANCED RULE] OR FACPE +LI_EBU + -fOR EOLRD ST002EE AUDIRLEE Specifications and Ordering Information Model Number Order Code Input Voltage Rated Candela Mounting Options*** Agency Approvals UL MEA CSFM FM BFP MT-12/24-R 5023 12/24 - D,E,F,L,M,O,P,R X X X X X MT-1 2/24-W 5024 12/24 - D,E,F,L,M,O,P,R X X X X X MT241575WFR# 8422 24 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MT-24MCW-FR 3301 24 15/30/75/110 D,E,F,L,M,O,P,R X * X * * MT-24MCW-FW 3303 24 15/30/75/110 D,E,F,L,M,OPP,R X * X * * MT121575WFR# 8421 12 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MT-121575W-NW 9747 12 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MTWP2475WFR** 8420 24 180 @ 77°F (25°C) M X X X X * MTWP2475WNW** 9744 24 180 @ 77°F (25°C) M X X X X * MT4-115-R 6223 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-S 6142 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-WH-VFR 6224 120 VAC 15 D,E,J,K,N,O,R X X X X X MT4-12/24-R 5308 12/24 - D,E,J,K,N,O,R X * * * * MT4-12/24-S 7997 12/24 - D,E,J,K,N,O,R X * * * * NOTE: **MTWP2475W is Weatherproof and rated for 180 cd @ 77°F (25°C). See Data Sheet S9004 or Installation Instruction P84150. ***For additional information on mounting please refer to Data Sheet S7000. * # 1575 strobes are UL Listed for 15cd with 75cd on AXIS. Pending ## Series WH Strobe is listed for UL Standard 1638 only. See Instruction Sheet P83160. 4JARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" P82467 MT-1 2/24, P84155 MT w/Strobe P84150 MTWP WEATHERPROOF "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). S2000 MT 10/07 Notification Architects and Engineers Specifications The notification appliance shall be a Wheelock Series MT audible/visual appliance or equivalent. Notification appliance shall be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic appliance shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN and HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. The Multitone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The audible and the strobe shall be able to operate from a single NAC circuit while producing any of these tones. The appliance shall provide two output sound levels: STANDARD and HIGH dBA. The HIGH dBA setting shall provide a minimum 5 dBA increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 99 dBA minimum. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens or equivalent with solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range. The MT strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for 1575cd multi-candela with field selectable 15/30/75/110 candela settings. The 1575 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe Models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances shall be installed indoors and may be surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red color. The Series MT-1 2/24, MTWP and MT4 appliances may be installed indoor or outdoor with the proper back box. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0155 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc., 273 Branchport Ave, Long Branch, NJ 07740 Contact: Lyn Sorrentino (732) 962-7832 Fax (732) 962-7856 Email: Iyn.sorrentino@cooperindustries.com DESIGN: Models MT Multitone Sync *horn/strobes Models may be followed by 12 or 24 for voltage, followed by strobe/candela rating, followed by W for wall mount. Units may be followed by suffixes to designate lens lettering and plate color. The series can provide one of eight tone outputs. Model MT-24MCW, may be followed by a letter indicating enclosure color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 voltage: 8-17.5 VDC 24 voltage: 16-33 VDC Flash rate: 60 flashes/mm Candela: Models 1575: 15cd (75cd on axis) Models 75:75cd Models MCW: 15cd, 30cd, 75cd or 1 10c INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For wall mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as *horn/strobes suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only.For synchronized strobes, Models SM-12/24, or DSM-12124 Sync Module (CSFM Listing No. 7300-0785:132) must be used. Refer to manufacturer's Installation Manual for details. These units can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Rev. 05-25-10 bh TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an /f endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-3 4LV 4y FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected pro perty: Address: )1 / Pr Representative of protected property (name! hone): JktA L4LE,2-C' Authority having jurisdiction; iflo Address/telephone number: C WkS 6A J Organization name name/phone Representative name/phone Installer j .... Supplier fh)r Service organization Location of record (as-built) drawings: iD ocZ Location of operation and maintenance manuals: sW- l 1 -L S vtb Location of test reports: Pt rt rt A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): Effective date: Expiration date: System Software Operating system (executive) software revision level(s): Site-specific software revision date: Revision completed by: ____________________________________________________________________ (name) (firm) 1. Type(s) of System or Service ___NFPA 72, Chapter 6 - Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8 -Remote Station Telephone numbers of the organization receiving alarm:. Alarm:_._ Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: _____NFPA 72, Chapter 8— Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8 - Central Station Prime contractor: - Central station location: (NFPA 72,1 of 4) FIGURE 4.5.2.1 Record of Completion. 2002 Edition 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio Digital alarm communicator Two-way radio Others Means of transmission of alarms to the public fire service communications center: System location: NFPA 72, Chapter 9—AuxilIary Indicate type of connection: Local energy .___ Shunt Parallel telephone Location of telephone number for receipt of signals: Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system hs haen installel in accordance th the NFPA stand j;s as shown below, was inspected by CiN3U? ' on 'i4LLf I ,includes the devices shown in 5 and 6, and has been in service since 8 9 11 (circle all thatapply) tI--NFPA 72, Chapters 1 2 3 4 NFPA 70, National Electrical Code, Article 760 .1. Manufacturer's instructions Other (ecify): Signed: Date: Organization: t' Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attach d All operational features and functions of this system were tested by_CU4b'1 . T and found to be operating properly in accordance with the requirements of: dat XNFPA 72, Chapters 1 2 3 4 8 9 11 icircle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions Other (ecify): Signed: Organization: Date: 4. Signaling Line Circuits Quantity and Iss of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: L Style: Class: (NFPA 72,2of4) FIGURE 4.5.2.1 Continued 2002 Edition