HomeMy WebLinkAbout3207 GREY HAWK CT; ; FA150011; Permit1/9/25, 7:17 AM FA150011 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FAI500II 3207 GREY HAWK Job Address: Status: ISSUED CT Permit Type: FALARM Applied 2/6/2015 Parcel No: 2210150100 Approved: 2/13/2015 Lot #: 0 Reference No.: Issued: 2/13/2015 PC #: Inspector: Project Title: 3E COMPANY ADD A NEW ANNUNCIATOR ON THE 2ND FLOOR IN IT AREA PER OWNER'S REQUEST. -THIS IS AN EXISTING MANUAL AND AUTOMATIC ACTIVATED FIRE ALARM SYSTEM. - THE IS AN ADDITION TO A COMPLETE 24 VDC CLOSED CIRCUIT, MICROPROCESSOR BASED ELECTRICALLY SUPERVISED, ANNUNCIATED FIRE ALARM SYSTEM AS SPECIFIED HERE ON THESE PLANS. THE SYSTEM SHALL INCLUDE BUT NOT BE LIMITED TO ALL CONTROL PANELS, POWER SUPPLIES, SIGNAL INITIATING DEVICES, AUDIBLE AND VISUAL ALARM DEVICES, WIRE, AND ACCESSORIES REQUIRED TO PROVIDE A COMPLETE OPERATING SYSTEM. THE SYSTEM SHALL BE WIRED AS A (CLASS B) SYSTEM FOR ALL CIRCUITS. Applicant: STANDARD ELECTRONICS 9340 STEVENS RD SANTEE CA 619-596-9950 Owner: CONCOURSE ONE LLC C/O LEE PACHECO 130 VANTIS #200 ALISO VIEJO CA about:blank 1/2 1/9/25, 7:17 AM FA150011 Permit Data Fees ($) Add'I Fees ($) Total ($) Balance ($) 289 0 289 0 about:blank 2/2 Ph: (619) 596-99SO Fax (619) 596-8850 i St andarflk; Road On1csJC7, CIO LIC. #590876 s%#o SUBMITTAL SHEET -F LE Cgorm" F PROJECT: 3E Company - Annunciator Addition 3207 Greyhawk Ct., Carlsbad, CA 92010 ARCHITECT: ELEC.ENGR: ELEC.CONTR: EQUIPMENT FA Panel Annunciator ITEM QTY DESCRIPTION MODEL NO. DATA SHEET Remote Serial Annunciator, LCD Display SFIVI#7300- 1 1 1703:0106 LCD-7100 FCI 2 200 2 conductor, 16 AWG, Unshielded, Jacketed Dl 62F WCW CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1703:0106 Page 1 of 1 CATEGORY: 7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Brian Reynolds (204) 484-6124 Fax (203) 484-7309 brian.reynolds2honeywell.com DESIGN: Mt LCD-71 00 remote serial annunciator. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote annunciator for use with separately listed model 7100 fire alarm control unit (CSFM Listing No. 7165-0494:219). NOTE: FORMERLY: 7300-0694:231 0 11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Fire/Life Safety SmartWirerM UL Listed and Rated Type CMR or FPLR Multi-Conductor Non-Shielded Non-Plenum Fire Alarm CSFM# 7161-1727:0100 D162F - 16 AWG 2 Conductor Non-Shielded Non-Plenum Fire Alarm Descrition 16 AWS 2 conductor Bare U Copper, Non-Shielded Non- .'Plenum Fire Alarm, UL C(UL) 'CMR or FPLR UL Conductor Description 16 (Solid Bare copper) Insulation pv .010' c Color Code 'Black/Red Jacket tPVC 018 Marking FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND.' DEVICE / :ZONE ABCDEO 123456 'TB 9 16 AWO uL C(UL) CMR OR FPLR UL 75C R011S MADE IN THE USA Overall Diameter 178 Nom Capacitance 26 pF/ Ft. 'Nom. - iTemperature and Voltage 0 Cto 75 C / 300 Volt Rating rCable Weight 29 Lbs/Mft. - L.••..• Agencies Approvals: NEC Article 800, 760; UL C(UL) CMR or FPLR UL, RollS Compliant, Made in the USA