HomeMy WebLinkAbout3207 GREY HAWK CT; ; AS060059; Permit1/9/25, 7:15 AM AS060059 Permit Data City of Carlsbad Sprinkler Permit Permit No: A5060059 3207 GREY HAWK Job Address: CT Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: PC #: Project Title: CONCOURSE ONE Status: ISSUED Applied 4/4/2006 Approved: 10/13/2006 Issued: 10/13/2006 Inspector: Applicant: Owner: LINDLEY FIRE PROTECTION 2220 E VIA BURTON ANAHEIM CA 714-535-5761 Fees ($) Add'I Fees ($) Total ($) Balance ($) 390 0 390 J 0 about:blank 1/1 LINDLEY FIRE PROTECTION CO., INC. FIL E '~: 7 e*& y_- 7 This bun may be used for all welding processes or combinations of processes. The contractor shall document each welding procedure in accordance with the format shown below, or equivalent. The appropriate information shall he obtained from data obtained (luring the qualification of the procedure. Welding Procedures Specification No:J&'PS LP-11 Date: 12-9-98 Title of Standard (;overning Qualification: AWS D10.9 Level ol Qualification: AR-1 A R-3 X Title: Welding GMAW (insert welding process or processes) of P1 (insert material) to P1 (insert material). Scope: This procedure is applicable for GROOVE (insert groove and/or fillet welds) in piping systems within the range of 1_/2" (insert pipe or tube diameter) through 1_1/2" . The range of wall thickness shall be .065" through .154 . Welding may be performed in the following positions 1_( (IC, 2(.,, etc.), Base Metal: The base metal shall conform to P1 (list the applicable P-number groupings, see Table 2). When appropriate, insert AS'I'M or API specification, or otherwise describe by chemical analysis. Information on backing rings or consumable inserts shall be given here. Filler Metal: The filler metal shall conform to AWS specification No.7OS3 from AWS specification AS. 18 . This filler metal falls into F-number 6 and A-number 1_(see Tables 3, 4, and 5). If no AWS classification exists, or If the 'C' classification is used, the manufacturer's trade name and/or weld deposit chemical analysis shall be listed. Describe any special storage and drying requirements. Flux for Submerged Arc: N A The manufacturer's trade name shall be listed. Submerged Arc Weld Metal Analysis: N/A List the principal alloying elements and the range permitted if not covered by an applicable AWS Filler Metal Specification, Shielding Gas: The shielding gas, or gases, shall conform to time following composition and purity: ARGON -_75%_/_Co2_- _25% (insert gas or gases for nozzle and backing, the proportional parts, and flow rates). Joint Design and Tolerances: Sketches shall be made to show the details such as the groove angle, root face dimensions, the root opening, type of backing, the maximum mismatch permitted, the tolerance of each dimension, and any changes in joint design based on changes in thickness. Preparation of Base Metal: The edges of parts to be joined shall be prepared by TORCH & MACHINE Ct.J'I'I'ING (state whether machined, ground, oxygen cut, etc.). State cleaning methods to remove foreign materials from the mating and Joining surfaces prior to welding. Joint alignment shall be maintained by TACK (state which means are used such as Jig, fixtures, tack weld. etc.). If tack welds are used, describe the welding process to be used, whether they are to be removed as welding progresses, the number, and location. Electrical Characteristics: The current shall be DIRECT (state whether direct or alternating, and if alternating, give the frequency). The base metal shall be on the 1TT (negative or positive when direct current is used) side of the line. Preheat: This paragraph shall describe any preheating requirements. State approved methods of heating, the temperature, and the equipment required to measure time temperature. 50°F. MIN. , LOWER THAN 50°F. AMBIENT SHALL REQUIRE PREHEAT TEMP STICKS. ACCURATE WELD-TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE0 CALIFORNIA 90280 564-5879 ' 564-5870 Sample Form C: Typical Contractor's Welder QualifIcation leslsflec.osd This form or Its etulvIetit shall be used to document the rrqufts of welder qualification test, and shitimild he mwenmnpnnied by the weldlivit procedure record. Welder's name JUAN GONZALEZ Identification no. SS 1/ 632-165517 . Title of st im,ucli,rd uovernI n ipumatlficotlon.A W.S D10.9, AR-3 LEVEL Welding procculmire spm:eIfIention no. LFP1SM7 lct 110. #229 .. SMAW WCitJJti proccstesi Hose mitetal A- 135, GR. A I'-iiun,lier 1 Ii h'•iIiIPTlbC Pipe mliii siieivr 2" ( r0%ip niiitile N/A l:ille,. mnetith .A 5. 1 Pipe wall thickness .154" Classifications E-7018 A-nuu,ibcr _N/A 1111cr metal size .118" No. of bends or passes 1 Approx. volts 21-25. Appro. niiipis 90-110 Pir)L isitiomi: M- 2(.;- 5(;- (,(; i F 2 F_____________ 4 p: sl l)Ircctlon of wclmhimig UP ( mmp,lmihl. ,ioviiiiiPl) Fleciriciml chimirncheri.stics: D( :RI' X I)('SI' AC Gas shielding: (ii,(cs)N/A Flow rule N/A hiac kin: c',imism,,i,nh'Ie Insert (chmis :mnd I ype ) N/A hacking tilig N/A - (;.asjccJ_N/A ..I1r,w rate: Test results: N/A... Voluimie: N/A Vicumith inspect ,eçuifs SATISFACTORY Radiographic result N/A Rnmhimirr:uJill Rndiormuiih, no. Rcsui ts no. Itumhl - N/A Sectional or inaemostrtuctu,rai cx otninntlom, or fillet weld Irnetuire test results: Sped men no. Resuul Is Specimen no. - U riil Is NJA - (;,ilticuh-I,c,,ml 0cct I esul is Type Specimen no Results Type Specimen no. Results Face . SATISFACTORY Iace Root SATISFACTORY Root Side Side Pressure l)Cfl(l tesi results: N/A - Special tests. N/A Test coiidiichrd i'v Date 9-15-99 £ J RONALD NOB DEl OrganJ'ntinn LINDLEY FIRE PROTECTION, INC. Sigiwd: ACCURATE WELD TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE1 CALIFORNIA 90280 564-5879 ' 564-5870 Sample Form C: Typical Contractor's Welder QualifIcation Tests-Record This (of III or Its eiulvalet1t shall be used to docutne,,t (lie results or welder qunllIlcn(lon tests and slio,iki be nccoitipniiicd by (lie weldipig procedure record. Welder's nrniie: JUAN GONZALEZ lde,illricntk,ii ,10 SS# 632-16-5517 Title of tiicliiril Ittiverniflat qualification: A.W. S D10 •9 AR-3 LEVEL Welding proveiliire speclilentloit no. LFP1SM7 I'ct no._I/22S Wcldl,ig proccss(es) SMAW host uiictnl A-135, CR • A l'.iti,,il,e 1 to l'-ntunl,er 1 h'ipe iiin,,,eter 21' (ro;,i nninbc N/A Illlcr incisil .A 5.. 1 Pipe well ll,Ickness .154" Classifications E-7018 A,ii,,il,cr N IA rilkr ,netnl size 1 /,,! No. or bends or passes 1 Appro. volls21-25 Approx. iimps 90-110 J'lpe ii,IIloti W— ; _____________ 2(.;— 5(;_ ((; pl 21-*4 i I.. Direction or wcichl,ig UP (ti ili ill. ihr,wiihiihl IJecti1cnl ch:iracte,isllcs: lit R P X IWSI' AC Gas hicldin: (;is(cs) N/A Flow r:,tc N/A hiacicIn: Ct'tisiitti;utii liiscrt (class anti ty 1C ) N/A linckltig ring N/A N/A l:lrjwrntc. N/A Volume: N/A- Test rcsufls: VIs;,z,h itispecliuti results: SATISFACTORY - kahlloj!rapl,Ic results: N/A R'dloriipli fill. Results no. Results N/A Sectional or inucu,slr,iel itral cxo,iiinntIo,, or IJhlet weld fracture lest jesuIt,: Spedivien fill. Results Specimen no. Rrsiil Is (;uIl(Ie(I-llv,,tl Jest jesuIts Type Sped titen tin. RCS11115 ype Specimen mm. Restil Is Face SATISFACTORY Face Root SATISFACTORY Root Side Side Pressure Ilenci test results: N/A Special tests -_N/A Test coiuilmicled liv Detc:9—]5-99 .3NALE -, Orp,nntztinn: LINDLEY FIRE PROTECTION, INC. Signed ACCURATE WELBJESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE, CALIFORNIA 902 8 0 564-5879 • 564-5870 Sample Form C: Typical Contractor's. Welder-Qualification Tests Record rltls forin or Its equivalent sliall be used, to document the results of welder qualification tes t s e n d s h o u l d b e n c c o i , i p i i n i c d by the weldhig procedure record. Welder's name: -_JUAN GONZALEZ . Identification no. sS#632-16-5517 Title of standard voI,,ertiloipt •iunli(katIoii: A .W. S. .1)10.9, AR-3 LEVEL Welding procedure specification no. LF-1—GM-4 Fest no. 215 Welding process(es) GMAW linac ijictol A-135,CRA, l'-nti,,ihicr 1 to l'-nti,nber Pipe clintiecter (rotu1 nu,,il,cr N/A 1911cr metal A 5•18 Pipe well thickness 145" Chosslficnt bits ER7QS-3 A-numl,cr N/A 1911cr iiictai 517.e .035" No. of bends or passes Appro. volts 20 Approx. nuips 160 l'ipe position: M- 2(.;- ___________ M X IP 21-'-41-'— Direction of welding DOWN , 111)11 iii. ijuwultill IJectric,ii characteristics: l)CKI' X l)C.Sl' AC Gas shielding: (n5(es)ARGON/CO2 Igw r,te 25 CEll Hacking: ('nii,u,i,,,hile insert (class unit type) N/A flack lug ring N/A 14/A__I:Iow rile: Test results: N/A voIiimc,• N/A Visual iuspecl mu results: SATISFACTORY fladlogr;ipliic results: N/A l :uulipr;uiili indiogr:uIi I','. - - Restul ts no. Restil Is N/A Sectional or uuinewal mci unit cx a iuiinntluut or fillet weld Iruiettire test ,esui Is: N/A Speuiincnnn, Rc'stiltc Specimen no. R'uulIs (;IuichcI-hcu,d IC' type Specimen no. Results •lype Spccinicn on. Results Face SATISFACTORY Face Root SATISFACTORY Root Side Side Pressure bend lest results: NIA Special tests:-______ N/A lest cnu(tulclrd hv _AGG1JBAIE_ WELD _jTijA Datc_ 9/14/99 1; ,. .... RONALI, tIDE J.,EY Orginlzitinn: LINDLEY FIRE PROTECTION,INC. SIguird: ACCURATE WELD-TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE, CALIFORNIA 90280 564-5879 • 564-5870 Sample Form C: Typical Contractor's Welder Qualification Tests Record This forni or its ecinivient siinll be used to doctimnenl the rcsults of welder qualification tests umid sho u l d b e 1ccomnp)8nicd by time welding procedure record. Welders mmmc: JUAN GONZALEZ Identification no SS#632-16-5517 Title of stomiciurd v14,ernIna •uIIflcIlon: A.W. S • .D1O • 9, AR-3 LEVEL Welding ptoerdmirc s'cdflcntlofl no. LFP-1—GM-4 rest no. 215 Welding prc,ces(es)GNAW Base mmmcliii A-135, CR. A. P-numni'er 1 to I'-mmumn i,er 1 Pipe diameter 2" (lrou1 number N/A Filler 1110111 A 5.18 I'ipc well Ilmickness 145" Cins.%l flea (lolls ER7OS-3 A-nummil,cr N/A Piller mmmcmi 5i7.0 • 035" No. of bends or l,icscs 1 Approx. volts 20 Approx. nilit's 160 l'ipe position: M— 2(. _____________ (m( X IF— 21-'_ 4F I)IrccIIo,i of welding DOWN ( mml)hull. miowimimlll Electrical cimnrneterislics: I)(flI' X I)c5I' AC Gas shielding: (,5(c5)ARGON/CO2 now nile 25CFH Ilacic bit: C,'nmm mm,nlile insert (Class and type) N/A Uncklmmi rimi N/A (;ns(s) N/A Flow rate: N/A Volmimmmc N/A Teal results: Visual imispiectiomi resulls: SATISFACTORY - kndkiprapIiic results: N/A i;mmIiu'r,pIi Rimdbogr;mpii Results no. Results N/A Sectional or mmmne,ostrm,vltmn,l exnm,minntk,n or fillet weld frncRmrc test results: N/A - prti mmmcmi no. Results Specimen no. Resumi Is f;ukle(I.he mid I c';f Type Sped mimen no Result s I $Ile no. Results lace SATISFACTORY Face Root SATISFACTORY Root Side Side I'rcssurc Iicnd fect rumIts N/A Special tests: N/A Test colldlich,11hv _ ACC11RATE Date 9/14/99 RONALD S. MOBLEI•, Orgnnizitioii: LINDLEY FIRE PROTECTION,INC. Sigmird ACCURATE WELD TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE, CALIFORNIA 90280 564-5879 • 564-5870 Sample Form C: Typical Contractor's Welder .Ou alitication Tests Record This form or its equivalent shall be used to document the results of welder qualification tests and should be accompanied by the welding procedure record. Welders miuiic: JUAN GONZALEZ Identification no. SS/! 63216-5517 Title or standard povcrning i1uin11f1cn11o,i: A.W.S.D10.9, AR-3 LEVEL Welding rrocedurc specification no. LFP1SM6 Jest no. 222 Welding proccss(es) SMAW Base nietnl .A'135 ,CR._A P-number 1 to l'-,,u n-i her 1 11111Cip,e mliaimicler 1 1/2 '' 1 b (;roII number NA ____________________________________ / Filler ,nelm,l A.5 .1 Pipe wall IImick,icss . 104" Classifications E-7018___________________________________________ A-nui ,mul,cr N/A 1,18" 1 Filler metal size No. or beads or passes Approx. volts21-25 Approx. amps 90-110 Pipe position: u; 2(.;- ___________ (,(; X I F___________ 4l___________ 51: Direction of welding UP (uphill. downhill) Electrical clianucterislics: D(RI' X I)CSI' AC Gas shielding: Gas(es) N/A Flow rate N/A Backing: Consumable insert (class :111(1 type) N/A Hacking ring N/A - N/A N/A (;() rate: , Test results: Volume: N/A Visual inspect ion results: SATISFACTORY Radiographic recuilts: N/A ltadioj'rapll R midlogniphi no. Results no. Results N/A Sectional or Imiacrostruictutnh examination or fillet weld fracture test results: N/A - - Sped men no. Results Specimen no. Results N/A c;umnleul-hcnd Iet Type Specimen no. Results I VIM Specimen no. Results Face SATISFACTORY Face Root SATISFACTORY Root Side Side I'testitc l,cnd test results: N IA Special tests N/A iest cniittctd ACCURATE _WELD TESTING _LAE Date: 9/14199 /i ._ .... RONALD S. HOBLE. Orginizntir'un: LINDLEY FIRE PROTECTION,INC. Signed: ACCURATE WELD TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE, CALIFORNIA 90280 564-5879 S 564-5870 Sample Form C: Typical Contractor's Welder Qualification Tests Record ibis rorin or its equivalent shall be used to document the results of welder qualification tests and should lie nccoiiiptiuuled by the welding procedure record. Welder's name: JUAN GONZALEZ Identification ni,. SS1/ 632-16-5517 A.W.S.D1O.9, AR-3 LEVEL Title of sin,iulatd ycivcrnluig quta1111ca11oii Welding procedure specification no. LFP1SM6 lest no. 222 Welding process(es) SMAW Base metal A-135 ,GR .A t'-nuni bcr 1 to l'iiti iii l)L' 1 1 1/2 '' i'ipit? ihi.it,,cler Croi,p n,it,,hcr N/A ________________________________ Filler ,neli,l A_5.1 J'hpe wall thickness 104'' Classifications E-7018 A-;iui unter N/A 1 /811 ruler metal 517e No. of bends or passes 1 Approx. volts 2 1-25 Approx. amps 90-110 l'ipe position: I 2(;- 5(;- M X 111' 2F 4 r it.- Direction of welding UP (uphill. downhill) Electrical characteristics: l)CR I' X DC.Sl' AC Gas shielding: (;() N/A Flow rate N/A Hacking: Consuniuble insert (class and (ype) N/A flocking ring N/A , ---'--c;)— I,w rate: N1 Vohuupiuc: N/A Test results: Visual inspection results: SATISFACTORY Radlogr;iphulc results: N/A fl;udiupr:u ph Riidlogr;iph, no. Results no. flesuil is N/A Sectional or uiacrostructur;,I examination or fillet weld fracture test results: N/A - - -- Specimen no. Results Specimen no. Results N/A Guided-hcndi-er fcsuihlf Type Specimen no. Results I ype Specimen no. Results Pace SATISFACTORY Face Root SATISFACTORY Root Side Side Vresre bend test results: N/A - Special tests: N/A lest conducted hy ACCURA.Th_ WELD _11ETJNG LAB Date. 9114/99 RONALD S. MOBLEY Organizntinn: LINDLEYFIREPROTECTION,INC. Signed ACCURATE ~-w WELD.-TESTING LAB 5223 TWEEDY BOULEVARD qnlJTH GATE, CAL;FORNIA 90280 584-5879 • 564-587C Sample Form C: Typical Contractor's Welder Qualification Tests Record this form or Its cijuivalent ilinli be used. to dociutuent the results of welder qualification tests and s h o u l d he accompanied by the welding procedure record. Welder's itnune: JIJAN_GONZALEZ_- Identificotioui no ss//632165517 Title of susuidard i!(Acrn1nR miiuellflcetlo,i: A.W4. _1)10•9,AR-3,LEVEL WeldIng procedure u,'ccllknlion no._LFP-1—GM--4 Test no. 215 Welding proccss( us) GNAW Vase mcliii A-135. GR. A. I'-uitu,nl,er 1 to l'-n,irnber 1 l'lpe diameter . Ciroup nui,uul,ur N/A Filler utietiul A5•18 PIpe well thickness 145" Clatti lien I bus ER7053 N/A t111er metal si.e .035" No. of bciicls or passes Approx. volts 20. Approx. anips 160 pipe position: M- _____________ b(; x It: 41: jJ. Direction of WCI(tlng DOWN jujillill. downhill) llectrk,,l characteristics: I)Cftl' X t)CSI' AC Gas sliieldlnr: (;ns(es)ARGON/CO2 Flow ni(e 25CFH flciclni: Couiiuutuolulv luiserl (eliuss uuiid tyl'e) N/A llncklui 1111$) N/A -_N/A .i!iow rate: N/A Voitiuiuc: N/A El Test results: Vlsui,ul inipecikiuu results: SATISFACTORY Radiographic results: N/A - It mull, q.r;i ph ftndlograu pit flu'. Kestuiti no. Results N/A Sectional or •uincroslructt,rnl cxai,ul,intio,i or fillet weld fracture test results: N/A Specimen no. Results Specimen no. Results N/A c;t,IilvtI-l'vuid Iccl results: Spccin,cn 110. Results . Typl. Specimen no. Results lace SATISFACTORY Pace Root SATISFACTORY Root Side Side l',estirc bend lct results: N/A -- - Spcci:tI tests: N/A Test coucluicteti by-ACPATE_W'_Ii_TESTINGLAB Date: 9/14/99 RONALD S. MOBLUV 0rginizntion: LINDLEY FIRE PROTECTION, INC. Sigtwd: ACC IRATE- WELD TESTING LAB :.'JEEDY BOULEVARD LOUTH GATE,CALIFORNIA 90280 (323)564-5879 9(323)564.5870 Test Results: Visual inspection results l.iqiaitl peuletraul results Magnetic Particle Results Radiographic results SATISFACTORY N/A - N/A N/A Radiograph no. Results Radiograph no. - Results N/A Tensile test results N/A no. Width DimensionsSpecimen Thickness Area Ultimate load, lb Tensile Fracture strength, psi location N/A - (;ulded-bend tests Type Specimen no. Results Type Specimen no. Results FACE SATISFACTORY ROOT SATISFACTORY Special tests results N/A Welder's name Juan Gonzales Identification no. SS*632-16--5517 Test conducted -by AdURATE WELD TESTING- Test approved 9/14/99 LAB 1/:215 Test witnessed b J_,2_... RONALD S. MOBLEY We certify that the statements in this rec,r re correct and that the test welds were prepared, welded, and tested in accordance with the requirements of D1o.9 (State title and level of standard governing qualification.) AR-3 Signed Date - Company LINDLEYFIREPROTECTION,INC. Sketch of Joint Design Show Joint designs for each pipe size-wall thickness grouping. Include details of weld groove if used, the root face, the root opening, mismatch, and tolerances. EDLEY LINDLEY FIRE PROTECTION CO., INC. Welding Conditions Shielded metal ire #215 Puss no. IIectrode Amps Volts AC, i)CSP, or DCRP - Stringer or weave head Vertical up or (loWil Size Class Oxyacetylene or oxyhyulrogcn Pass 114). Filler metal . lip size Gas pressure Iorchand Forehand or backhand Flame character Size Class Oxygen Fuel Gas tungsten arc Filler metal no. Size Class Pass - Consumable Insert Range of welding t)CSP, DCRP, or AC g' Ira- quency Shielding gas Composition Flow-efli Class/Type AmpS Volts Torch Backing Torch Backing Electrode holder Tungsten Nozzle Open circuit voltage Slope coni rul ________________________________ Head technique Class I Size I prep. Type A,iglc Type Size Start I Fiuuisl, (',as metal arc or flux cored are welding Pass no. IjlIcr metal flange of welding J)CSP, DC.RP, or AC Travel speed, 11)111 Shielding gas Vertical up or down Composition Flow cfh Size Class Amps Vol Is Gun Backing Giuiu Backing 1 035" R70S-3 160 19-21 DCRP 3 ARGON N/A 25 NJA DOWN E 11cc Ii ode - hohic; Slope couul 1(11 open circuit vollaie t'oz.ie Dist 111(1' I IHIl WOrk Typic Auip!ie Start Finish Type Size Nozzle - f.le:Irotfe N/A N/A_ N/A N/A N/A CC J 5/8" 518" 3/8" I ]k L UNDLJ". LINDLEY FIRE PROTECTION CO., INC. Sample Form B: Typical Contractor's Procedure Qualification Test Record (PQR) Contractor: LINDLEY FIRE PROTECTION CO., INC. Date: 9/8/99 The contractor shall record the applicable conditions described in this document in sufficient detail during the preparation and testing of the sample welds to assure that the welding procedure has been qualified. Qualified to Welding Procedure No: WPSLFP1—GM— Date: 9/8/99 P0k No 215 for AWS AR-1 for AWSAR-3 * X Welding Process(es) GNAW Type of Machine ELECTRIC Welding Method(s): Manual Semiautomatic _X Machine Automatic Material Specification A135, GR. A. to A135, CR. A. Position 6G Pipe Diameter 2" Wall Thickness Filler Metal Specification No./Classification No. A-5.18 /ER70S-3 Consumable Insert Classification No. and Type N/A Flux Specification No., Classification No., Composition, Manufacturer's Trade Name N/A lype of Joint SINGLEVGROOVE WELD Welding lecliiiiqtie STRINGER BEAD Backing (king, Filler Metal, Gas, e(c.) NONE Surface Preparation TORCH CUT WIRE BRUSH OR GRIND AS NEEDED ['recleaning NONE Preheat 65°F, AMBIENT Tack Welds NIN.2 Method at Joint Alignment: Internal NONE External NONE (Clamps, etc.) Peening NONE Method of Ate Initiation MANUAL Interpass Je iii perattire N/A, SINGLE PASS Cleaning During Welding N/A,SINGLE PASS Back-Gouging Method N/A Inspection Prior to Welding VISUAL Inspection During Welding VISUAL Inspection Alter Weldimie VISUAL NONE Space Itimmitatmoos (it any) NONE NDY LINDLEY FIRE PROTECTION CO., INC. Sample Form A: Typical Welding Procedure Specification (WPS) This form may he used for all welding processes or combinations of processes. The contractor shall document each welding procedure in accordance with the format shown below, or equivalent. The appropriate information shall be obtained from data obtained during the qualification of the procedure. 'Melding Procedures Specification No: WPS LFP-1GN Date: 9/8/99 Title of Standard Governing Qualification: A.W. S. D1U. 9 Level of Qualification: AR- I AR-3 A Title: Welding GNAW (insert welding process or processes) of_P1 (insert material) to P1 (insert material). Scope: This proedure is applicable for GROOVE (insert groove and/or fillet welds) in piping systems within the rngc of 2 (insert pipe or tube diameter) through 2011 . The range of wall thickness shall be • 154 through .375" . Welding may be performed in the following positions ALL (1(;. 2G, etc.). Base Metal: The base metal shall conform to P1 (list the applicable P-number groupings, see Table 2). When appropriate, insert ASIM or API specification, or otherwise describe by chemical analysis. Information on hacking rings or consumable inserts shall be given here. Filler Metal: The filler metal shall conform )o AWS specification No.ER70S3 from AWS specification A5. 18 . This filler metal falls into F-number 0 and A-number i (see Tables 3, 4, and 5). If no AWS classification exists, or if the 'G' classification is used, the manufacturer's trade name and/or weld deposit chemical analysis shall he listed. Describe any special storage and drying requirements. Flux for Submerged Arc: The manufacturer's trade name shall be listed, Submerged Arc Weld Metal Analysis: N/A List the principal alloying elements and the range permitted If not covered by an applicable AWS Filler Metal Specification. Shielding Gas: N/A The shielding gas, or gases, shall conform to the following composition and purity: (insert gas or gases for nozzle and backing, the proportional parts, and flow rates). ARGON - 75% / CO2 - 25% Joint Design and Tolerances: Sketches shall be mode to show the details such as the groove angle, root face dimensions, the root opening, type of backing, the maximum mismatch permitted, the tolerance of each dimension, and any changes In joint design based on changes in thickness. Preparation of Base Metal: The edges of parts to be joined shall be prepared by TORCH & MACHINE CUTTIN state whether machined, ground, oxygen cut, etc.). State cleaning methods to remove forejn materials from the mating and joining surfaces prior to welding. Joint alignment shall be maintained by TACK (state which means are used such as jig, fixtures, tack weld, etc.). If tack welds are used, describe the welding process to be used, whether they are to he removed as welding progresses, the number, and location. Electrical Characteristics: The current shall be DIRECT state whether direct or alternating, and if alternating, give the frequency). The base metal shall be on the POSITIVE (negative or positive when direct current is used) side of the line. Preheat: This paragraph shall describe any preheating requirements. State approved methods of heating, the temperature, and the equipment required to measure the temperature. 50°F MIN., LOWER THAN 50°F AMBIENT SHALL REQUIRE PREHEAT TEMP. STICKS. N/A ACCURATE WELD TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE, CALIFORNIA 90280 564-5879 0 564-5870 Sample Form C: Typical Contractor's Welder Qualification Tests Record This form or its equivalent shall he used to document the resull s of welder qualification tests and sliotilti be accompanied by the welding pr()ec(lnre record. Welders FRANCISCO VASQUEZ hlcnlilicalioui no. S.S. 563-53-2258 Ilile of st n,olnr,I g vernlng ,siillfi(iiIioii : ._A .W • S D10 • 9 • AR-3 LEVEL Welding procedure specification no. LFP-1—SM-8/F Test no. // 394 Welding pr(lcrss( es ) SMAW 13as ii.el iii A-135_GR._A P-nuii, her 1 to 11-member Pipe ilI;i,,icicr, 1 1/2" (;roiip niiiiiiwr N/A Filler suet at A5•1 I'li'c wall thick— • 104" Classifications E-7024 A-uiu usher N/A Filler uuicluii size 1/8" No. of beads or passes 1 Approx. volts 23-25 Approx. anips 100 Pipe position: 1(;_ _____________ 5(,_ _____________ It: 2 F X 41'•_____________ Si: I)lrccllon of wehuiluig N/A (ui'luitl. clow,iliuii) Electrical characterisiles: DCUJ' X l)C.Si'AC Gas shielding: (a-;(es) N/A Flow r;,c N/A Backing: Crisisui,,uahle Insert (class and I ype I N/A Backing ring N/A (;as(ts) N/A iiw rate: N/A Vohuiuic: N/A Test results: Visual inspection u esuhls: SATISFACTORY Radiographic results: N/A Radiograph lu(iui)graIII 'I'). Results sb. RiIIs N/A Sectional or puiacrostruct,,ral cxauuiinsitlo,i or fillet weld fracture test results: Sped uiien no. Results Specimen no. Res ul Is SATISFACTORY 3. SATISFACTORY SATISFACTORY 4. SATISFACTORY (;ilkle(l-he,,d tcl restulis: N/A Type Specimen no. Results Type Specimen no. Results Face N/A - Face Root Side - - Side I'rcsgturc bend lest results: Special tests: Test conducted by:ACQIJRA Jr. Ili _TESTI Mr. LAB j RONALD S. MOBLEY l)atc: 12/10/98 Organization: LINDLEY FIRE PROTECTION, INC. ACCURATE WELD TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE, CALIFORNIA 90280 (323)564-5879 0(323)564-384 Test Results: Visual inspection results SATISFACTORY liquid penetraw results N/A Magnetic Paiticle Results N/A Radiographic results N/A It 11 tilogra ph Radiograph no. Results no. Results N/A Tensile test results N/A Dimensions Specimen Ultimate I cnsik Fracture no. Width Thickness Area load, lb strength, psi location N/A Guided-bend tests N/A Type Specimen no. Results Type Specimen no. Results N/A Special tests results MACRO ETCH TESTS 1. SATISFACTORY, 2. SATISFACTORY, 3. SATISFACTORY, 4. SATISFACTORY Welder's name FRANCISCO VASQUEZ Identification no. S.S. 563-53-2258 Test conducted byACCURATE WELD TESTING lest approved 12/10/99 LAB 11: 394 Test witnessed by RONALD S. MOBLEY We certify that the statements in this record are correct and that the test welds were prepared, welded, and tested in accordance with the requirements of D10.9 (State title and level of standard governing qualification.) AR-3 Signed Date 12/10/99 Company LINDLEYFIRE PROTECTION, INC. Sketch of Joint Design Show joint designs for each pipe size-wall thickness grouping. Include details of weld groove if used, the root face, the root opening, mismatch, and tolerances. ELEY LINDLEY FIRE PROTECTION CO., INC. Shielded itietal are Pass no. llect rode Amps Volts Ac, DCSP, or DCRP Stringer or weave head Vertical tip or down Size Class 1 1 /8 1-7024 100 23-25 A. C. STRING N/A Oxyacetylene or oxyhyilrogcn Pass M). Filler metal . i Tip size Gas pressure Forehand or backhand Haune character Size Class Oxygen Fuel Gas tungsten are Filler metal Pass no. Size Class Consumable insert Range of welding DCSP, DCRI', or AC I ugh- quency Shielding gas Ire- Composition Flow-ctli Class/Type Amps - Volts Torch Backing Torch Backing Flectrode holder Tungsten Nozzle Open circuit voltage Slope control Bead technique Class I Size I prep. rype Angle Type Size Start Finish I I -- --I ---I i F. Gas metal arc or flux cored are welding Pass no. Filler nictal Range of DCSP, 1)CR I', or AC Travel speed, ipm Shielding gas up or (toWn Composition Flow CHIVertical Size Class Amps Volts Gun Hacking (tmii hacking Ficci ode holder Slope control ¶)P? voltage circuit Nozzle l)islaiict tioni work Ty i'e Angle Starf Finish Type Size Nuiiie Electrode Fj*0:0EL11' iNs" 'DEL E 7YNI LINDLEY FIRE PROTECTION CO., INC. LINDLEY FIRE PRCfrECI'ION CO, INC. _ ,)ale: 12-9-98 Contractor: racini: -- The &: Iliractol shall record the applicable conditions described in this document in sufficient detail during tilL piepaimion and testing of the saiiiple welds to assure that the welding procedure has been qualified. Qualified u Welding i'ree&lnre No: wps L''1SI4-8/F Date: 12-9-98 394 * I'(111I N:____________ for AWS AR- I for AWS Alt-i Weluliiig l'ucsdcs)SMAW Iye of t1ach1ue MYIOR DRIVENOR ELECTRIC )Vrl(li ''t: td ci butt Maiiuial_ Seiriiauitolllatic _____________________ Machine Auti>inalic Material Spccih.iiwii A-135,Gr.A to A-135,Gr.A Posilioll 2F.-- Pipe t)ianucter_ 1 '.'ail Ehickuess .104" Filler Metal Specification Nn./(tassilication No. A_5.1 /E7024 - oilslllllat)lc i,iscri Classification No. atiti Type N/A liux Specittciioii No., Classiiicaiion No., Composition, Muuniilactuircr's trade Name N/A lYI)e III Joi nt FILLETWELD Welding lChiiiitiic —STRINGER BEAD Backing ( Ring, Filicr Metal, 1;11s, etc.) NONE Surface Piej)alniioul MACHINE OR TORCH CUT, WIRE BRUSH ORGRIND AS NEEDED Precleaniiig NONE l'relical__. 650F., AMBIENT Tack Welds MIN.2 Method of J()illi Aligiiiiieuit: Internal NONE - lxternil NONE Peening NONE -- fs-letbuni of i\ IC Iiiiiatiuii Interpass tell) PCIal (IIC t.ieaniiig t)urnig \Veittiig liack-( o11g1ng Mel lllsi)ectio)l Priui to Veitllug IlIspectioll i)uiiiiig Vekting Inspection After Wetutittg_ IOsI licatitig Space Iitttilaliuiis 01 ally ) (Clamps, etc.) MANUAL N/A,SINGLE PASS N/A, SINGLE PASS VISUAL VISUAL VISUAL NONE LINDLEY FIRE PROTECTION CO., INC. This fort)) niay be used for all welding processes or combinations of processes. welding procedure in accordance with the format shown below, or equivalent. obtained from data obtained (luring the qualification of the procedure. Welding Procedures Specification No: J&'PS LFP-1 —98/F Date Title of Standard Governing Qualification: AWS D10.9 Level of Qualification: A l(- I A R-3 * 'l'hie contractor shall document each rime a pproprin to information shall be 12-9-98 Title: Welding SMAW (insert welding process or processes) of P1 (insert material) in P1 (insert material). Scope: This procedure is applicable for GROOVE (insert groove and/or fillet welds) in piping systems within the range of 1/2" (insert P11e or tube diameter) through 1_1/2" . The range of wall thickness shall be .065" through _1_54' . Welding may he performed In the following positions IF, 2F (I G, 2G, etc.). Base Metal: The base metal shall conform to Pi (list the applicable P-number groupings, see Table 2). When appropriate, insert ASTM or API specification, or otherwise describe by chemical analysis. Information on backing rings or consumable inserts shall be given here. Filler Metal: The filler metal shall conform to AWS CLASS NoE-7024 from AWS specification AS. 1 . This filler metal falls into F-number 1 and A-nuniber 1_(see Tables 3, 4, and 5). If no AWS classification exists, or if the 'G' classification Is used, the manufacturer's trade name and/or weld deposit chemical analysis shall be listed. Describe any special storage and drying requirements. Flux for Submerged Arc: N The manufacturer's trade name shall be listed.- Submerged Arc Weld Metal Analysis: N/A List the principal alloying elements and the range permitted if not covered by an applicable AWS Filler Metal Specification. Shielding Gas: N/A The shielding gas, or gases, shall conform to the following composition and purity: (insert gas or gases for nozzle and hacking, the proportional parts, and flow rates). Joint Design and Tolerances: Sketches shall be made to show the details such as the groove tingle, root face dimensions, the root opening, type of backing, the maximum mismatch permitted, the tolerance of each dimension, and any changes In joint design based on changes in thickness. Preparation of Base Metal: 'l'hc edges of parts to be joined shall be prepared by 'IORcH& MACHINE CU'ITING (state whether machined, ground, oxygen cut, etc.). State cleaning methods to remove foreign materials from the mating and joining surfaces prior to welding. Joint alignment shall be maintained by TACK (state which means are used such as Jig, fixtures, tack weld, etc.). If tack welds are used, describe the welding process to be used, whether they are to he removed as welding progresses, the number, and location. Electrical Characteristics: The current shall be DIRECT (state whether direct or alternating, and if alternating, give the frequency). The base metal shall he on the NATIVE (negative or positive when direct current is used) side of the line. Preheat: This paragraph shall describe any preheating requirements. State approved methods of heating, the temperature, and the equipment required to measure the temperature. 50°F. MIN. , LOWER THAN 50°F. AMBIENT , SHALL REQUIRE PREHEAT TEMP STICKS. ACCURATE WELD TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE, CALIFORNIA 90280 564-5879 ' 564-5870 Sample Form C: Typical Contractor's Welder Qualification Tests Record Iiiis form or its equivalent shall he used to docui,ic,i t tile results of welder qu;il i fication tests atid should he ICCOIlI Pulled by the welding pri,cedsire record. Welder's name: FRANCISCO VASQUEZ Identification nO. S.S. 563-53-2258 Title of stn,,,h,ir,I piverning ll(IuuifiCLitlon: A.W.S. D10 .9. AR-3 LEVEL Welding vrocctlurc specification no. LFP-1-GM1 lest no. _#388 Welding process(es) Ilipse tue Pal _A-135 GR. A P-nu tuber 1 to I'-,uiu iui,cr l'ipe diii tue Icr 1 1/2" (r01tp number N/A IllIer .uiei;il A.,. 5 • 18. Pipe wail thickness .104" Ciasciliciutlons ER-70S-3 A-number N/A 1111cr metal size .035" No. of beads or passes 1 Approx. volts 151 Approx. pi,ups 100 Pipe position: I( X 26 5(;- (u( IF 2F 4F___________ l)ireciion of welihliug N/A (uphill. downhill) I:icctricah characteristics: DCRI' X D("SI'AC Gus shielding: (as(es) Ar/Co2 - Flow rate 25CFH Ducking: Cnnsuu,uuiihhe insert (class and type) N/A hacking ring N/A (;asks)NJA flow rate:N/A Volume: N/A Test results: Visual inspection results: SATISFACTORY Radiographic res!IlIs: N/A Radii itrI ph Ru (II og ri pit no. Results no. Restil Is N/A Sectional or iiiucrostrtictu,rai examination or fillet weld fracture test results: N/A SpecIfic,, no. Restuhts Specimen no. Results N/A (;iiided-hicnd test results: Type Specimen no. Results Type Specimen no. Results l:o C SATISFACTORY Face Root SATISFACTORY Root Side Side Pressure bend test results: N/A Special tests: N/A Test conducted by: ACCIIRA WELD TESTING LAB Date: 12110/98 'RONALD S-. -MOLEY e Organization: LINDLEYFIREPROTECTION,INC. Signed: ACCURATE WELD TESTING LAB 5223 TWEEDY BOULEVARD SOUTH GATE, CALIFORNIA 90280 (323)564-5879 0(323)564-3843 'I'cst Results: Visual Inslueci ion jesuits I .i1uiitI ie11et rant ,csuills Mognel k Pu I ide R csulls ltaJiogruupluic results SATISFACTORY N/A N/A N/A Radiograph ito. Results Radiograph no. Results N/A Tensile test results N/A no. VItlth Specimen Ultimate Dimensions Thickness Area load, lb Tensild Fracture strength, psi location N/A (;uihled-bend tests Type Specimen no. Results Type Specimen no. Results FACE SATISFACTORY ROOT SATISFACTORY Special tests results N/A Welder's utanic_FRANCISCO Test conducted by ACCURATE VASQUEZ Identification no. WELD TESTING . Test approved 12/10/98 S.S. 563-53-2258 LAB II: 388 Test witnessed by RONALD S • MOBLEY We certify that file statements in this record are correct and that the test welds 'A'ere prepared, welded, and tested In accordance with the requirements of_D1O.9 (State title and level of standard governing juahifica(lon.) AR-3 Signed Date 12/10/98 Company LINDLEY FIRE PROTECTION, INC. Sketch of Joint Design Show Joint designs for each pipe size-wall thickness grouping. Include details of weld groove if used, the root face, the root opening, misiuiátch, and tolerances. EY LINDLEY FIRE PROTECTION CO., INC. Shielded metal are Pass no. - Ht rode 1 Amps Volts AC, i)CSl', or DCRP Stringer or weave bead Vertical imp or (IowA Size Class Oxyacetylene or oxyliydrogen Pass M). Filler metal . i 1 p size Gas pressure Forehand or backhand Flame character Size Class Oxygen Fuel Gas tungsten are Filler metal Pass no. Size Class Consumable insert Range of welding DCSP DCRI', or AC I Ilh quency Shelling gas fre-- Composition Flow-cili Class/Type Amps Volts Torch Backing Torch Backing Flect rode holder tungsten Nozzle ________________ ________________ Open circuit voltage Slope control licyad technique (lass J Size I lfl(l prep. Type Angle Type Size Start Finish Gas metal arc or flux cored are welding Pass no. Filler metal Range of welding DOM, or AC 'I . yet Travel speed, ipni Shielding gasAr/O2 v CI fical up or (IOWA Composition Flow dli Size Class Amps Volts Gun Backing Gull Backing 1 .035" EMS-3 100 15 D.C. 1-3 75/25 N/A 25 N/A N/A Flect i ode holder Slope con(uml circuit voltage Open Nozzle l)isl imice Ii out wit? k Fype HAW Angle 450 Start N/A Finish N/A Type Size Nozzle Flect rod e A I so LINDLEY FIRE PROTECTION CO., INC. Contractor: LINDLEY FIRE PR(YI'EC'TION CO., INC. Date: 3-5-99 the cupitriettir shill record the applicable conditions described in this document in sufficient detail during the 11ICiIE;ItiuU and testing of the sitnple welds to assure that the welding pioce1uuie has been qualified. Qualitietl to Welding Proceiluiic No: WPS LFP1 —_1 l)uie : 12-9-98 l()U No: 388 ______ for AWS AR-I for AVS AK-3 X GMAW Welding lri ,csst c Welding tict luotl( I Type of Machine ELECTRIC Seiniautouivatic Machine Automatic M.teiial Sjeculicatitou A-135, Gr.A to A—i 35, Gr.A 213 I I I Pipe l)iaiiietci I _ U I! Wall lhiickiiess Filler Metal Specilication No./Classification No. A-5.18, 70S-3 (ouisiu,uable liisw I lassihcatiouu No. mid Type N/A 1-lux Specilicallouu No., Classification No., (oIIiposition, Maiitilacturei's trade Name N/A type mit jujiit SINGLE V GROOVE Welding lccliuiiqi :SIR BEAD Hacking (l<iim, Fifici Metal, (a5, etc.) NONE Suarfzice lmrcpasatioim TORCH CUT, WIRE BRUSH OR GRIND AS NEEDED tmrecleaniuig NO1.'Th l'relicat 50F. AMBIENT lack Welds MIN. 2 Metluul ut Joint Aligmimuient: Internal NONE lxterumal NONE (Claimups, etc.) Peening NONE letliod of ,r&: lniiiitimmii MANUAL hmiterpass l•eini)Cr.iioR -N/A, SINGLE PASS (:leauiiuin l)iiriuig 'vcltlinc N/A, S1:j(IE PASS liack-(.oimgimig Ilctlii)&l _N/A Inspection Prior to Welmijuig VISUAL InsImectitiut l)niing \Veliliug \7tSt..jTr Inspec tion After Weld i uig VISUAL I)IIICItIIIg_._ NONE NONE Space Ii iuutta touts (it all y I p LIT4DLEY FIRE PROTECTION CO. 2220 E. VIA BURTON ANAHEIM, CA 714-535-5761 HYDRAULIC CALCULATIONS FOR CONCOURSE ONE @ THE PALOMAR FORUM 3207 GRAYIIAWK COURT CARLSBAD, CA FIRST FLOOR DATE: 02-16-06 -DESIGN DATA- SYSTEM DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (INCLUDING HOSE) FLOW AND PRESSURE & BASE OF RISER: SPRINKLER ORIFICE SIZE: CONTRACTOR CERTIFICATION NUMBER: .15 GPM/SQ. FT. 1500 SQ. FT. 130 SQ. FT. 12 SPRINKLERS 250.5 GPM 500.5 GPM 250.5 GPM @ 89.5 PSI '/2" C16/C34N0. 713562 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOE TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) U3 109.8 104.4 1500.0 109.1 500.5 96.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 500.5 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 150.0 GPM OTHER HOSE STREAM ALLOWANCES 100.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 250.5 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Hi 12.9 K= 5.47 13.4 20.0 H2 12.9 K= 5.47 12.8 19.6 H3 12.9 K= 5.47 12.7 19.5 H4 12.9 K= 5.47 12.8 19.5 H5 12.9 K= 5.47 13.2 19.9 H6 12.9 K= 5.47 13.8 20.3 H7 12.9 K= 5.47 13.2 19.9 H8 12.9 K= 5.47 13.1 19.8 H9 12.9 K= 5.47 13.1 19.8 H10 12.9 K= 5.47 13.6 20.2 Hil 12.9 K= 5.47 22.7 26.0 H12 12.9 K= 5.47 22.6 26.0 1 12.2 - - - - 69.3 - - - 2 12.2 - - - - 69.4 - - - 3 12.2 - - - - 69.6 - - - 4 12.2 - - - - 70.0 - - - 5 12.2 - - - - 70.5 - - - 6 12.2 - - - - 71.1 - - - 7 12.2 - - - - 71.9 - - - 8 12.2 - - - - 74.5 - - - 9 12.2 - - - - 77.2 - - - 10 12.2 - - - - 76.9 - - - 11 12.2 - - - - 76.7 - - - 12 12.2 - - - - 76.6 -. - - 13 12.9 - - - - 70.8 - - - 14 12.9 - - - - 71.2 - - - 15 12.9 - - - - 71.3 - - - 16 12.9 - - - - 70.1 - - - 17 12.9 - - - - 70.1 - - - 18 12.9 - - - - 70.2 - - - 19 12.2 - - - - 64.0 - - - 20 12.2 - - - - 64.0 - - - 21 12.2 - - - - 63.8 - - - 22 12.2 - - - - 63.6 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 23 12.2 - - - - 64.6 - - - 24 12.2 - - - - 65.5 - - - 25 12.2 - - - - 67.9 - - - 26 12.2 - - - - 68.4 - - - 27 12.2 - - - - 70.1 - - - 28 12.2 - - - - 70.4 - - - 29 12.2 - - - - 70.6 - - - 30 12.2 - - - - 70.7 - - - 31 12.2 - - - - 23.3 - - 32 12.2 - - - - 24.1 - - - 33 12.2 - - - - 26.7 - - - 34 12.2 - - - - 30.3 - - - 35 12.2 - - - - 33.4 - - 36 12.2 - - - - 38.1 - - - 37 12.2 - - - - 33.8 - - - 38 12.2 - - - - 31.7 - - - 39 12.2 - - - - 31.4 - - - 40 12.2 - - - - 31.2 - - - 41 12.2 - - - - 31.1 - - - 42 12.2 - - - - 31.0 - - - 43 12.9 - - - - 29.6 - - - 44 12.9 - - - - 30.1 - - - 45 12.9 - - - - 30.1 - - - 46 12.9 - - - - 28.6 - - - 47 12.9 - - - - 28.6 - - - 48 12.9 - - - - 28.8 - - - 49 12.2 - - - - 21.7 - - - 50 12.2 - - - - 22.3 - - - 51 12.2 - - - - 24.5 - - - 52 12.2 - - - - 27.0 - - - 53 12.2 - - - - 28.1 - - - 54 12.2 - - - - 28.8 - - - 55 12.2 - - - - 29.4 - - - 56 12.2 - - - - 29.7 - - - 57 12.2 - - - - 29.9 - - - 58 12.2 - - - - 30.1 - - - 59 12.2 - - - - 30.1 - - - 60 2.0 - - - - 88.3 - - - TOR 12.2 - - - - 82.5 - - - BOR 0.0 HOSE STREAM 89.5 100.0 Ui 0.0 - - - - 90.1 - - - U2 0.0 - - - - 93.6 - - - U3 -6.0 SOURCE 96.4 350.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST. FL .15 FOR 1500 SQ FT GROUP 1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 25.2 1.508 PL 119.50 PF 5.3 1 12.2 0.0 69.3 0.0 4.5 120 FTG 3T3L PE 0.0 19 12.2 0.0 64.0 0.0 0.034 TL 155.50 PV Pipe: 2 25.8 1.508 PL 116.25 PF 5.4 2 12.2 0.0 69.4 0.0 4.6 120 FTG 4T PE 0.0 20 12.2 0.0 64.0 0.0 0.036 TL 152.25 PV Pipe: 3 . 26.9 1.508 PL 116.25 PF 5.9 3 12.2 0.0 69.6 0.0 4.8 120 FTG 4T PE 0.0 21 12.2 0.0 63.8 0.0 0.038 TL 152.25 PV Pipe: 4 26.4 1.508 PL 116.25 PF 5.4 4 . 12.2 0.0 70.0 0.0 4.7 120 FTG 3TL PE 0.0 23 12.2 0.0 64.6 0.0 0.037 TL 146.25 PV Pipe: 5 . 25.2 1.508 PL 116.25 PF 5.0 5 12.2 0.0 70.5 0.0 4.5 120 FTG 3TL PE 0.0 24 12.2 0.0 65.5 0.0 0.034 TL 146.25 PV Pipe: 6 0.7 1.508 PL 18.50 PF 0.0 6 12.2 0.0 71.1 0.0 0.1 120 FTG 2T PE -0.3 13 12.9 0.0 70.8 0.0 0.000 TL 36.50 PV Pipe: 7 10.5 1.508 PL 18.50 PF 0.3 7 12.2 0.0 71.9 0.0 1.9 120 FTG 3T PE -0.3 14 12.9 0.0 71.2 0.0 0.007 TL 45.50 PV Pipe: 8 35.3 1.508 PL 18.50 PF 2.9 8 12.2 0.0 74.5 0.0 6.3 120 FTG 3T PE -0.3 15 12.9 0.0 71.3 0.0 0.063 TL 45.50 PV Pipe: 9 25.5 1.508 PL 149.75 PF 6.5 10 12.2 0.0 76.9 0.0 4.6 120 FTG 4T PE 0.0 28 12.2 0.0. 70.4 0.0 0.035 TL 185.75 PV Pipe: 10 24.6 1.508 PL 149.75 PF 6.1 11 12.2 0.0 76.7 0.0 4.4 120 FTG 4T PE 0.0 29 12.2 0.0 70.6 0.0 0.033 TL 185.75 PV Pipe: 11 24.4 1.508 PL 149.75 PF 5.9 12 12.2 0.0 76.6 0.0 4.4 120 FTG 4T PE 0.0 30 12.2 0.0 70.7 0.0 0.032 TL 185.75 PV Pipe: 12 22.7 1.508 PL 27.50 PF 0.8 13 12.9 0.0 70.8 0.0 4.1 120 FTG ---- PE 0.0 16 12.9 0.0 70.1 0.0 0.028 TL 27.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 18.2 1.508 PL 81.25 PF 2.0 17 12.9 0.0 70.1 0.0 3.3 120 FTG 3T PE 0.3 26 12.2 0.0 68.4 0.0 0.019 TL 108.25 PV Pipe: 14 7.1 1.508 PL 103.75 PF 0.4 18 12.9 0.0 70.2 0.0 1.3 120 FTG 3T PE 0.3 27 12.2 0.0 70.1 0.0 0.003 TL 130.75 PV Pipe: 15 23.8 1.508 PL 30.75 PF 1.1 15 12.9 0.0 71.3 0.0 4.3 120 FTG 2L PE 0.0 18 12.9 0.0 70.2 0.0 0.031 TL 36.75 PV Pipe: 16 21.2 1.508 PL 81.25 PF 2.5 16 12.9 0.0 70.1 0.0 3.8 120 FTG 2T PE 0.3 25 12.2 0.0 67.9 0.0 0.025 TL 99.25 PV Pipe: 17 -21.9 1.508 PL 6.67 PF 0.4 13 12.9 0.0 70.8 0.0 3.9 120 FTG T PE 0.0 14 12.9 0.0 71.2 0.0 0.026 TL 15.67 PV Pipe: 18 -11.5 1.508 PL 7.29 PF 0.1 14 12.9 0.0 71.2 0.0 2.1 120 FTG ---- PS 0.0 15 12.9 0.0 71.3 0.0 0.008 TL 7.29 PV Pipe: 19 1.5 1.508 PL 6.67 PF 0.0 16 12.9 0.0 70.1 0.0 0.3 120 FTG T PE 0.0 17 12.9 0.0 70.1 0.0 0.000 TL 15.67 PV Pipe: 20 -16.7 1.508 PL 7.29 PF 0.1 17 12.9 0.0 70.1 0.0 3.0 120 FTG ---- PE 0.0 18 12.9 0.0 70.2 0.0 0.016 TL 7.29 PV Pipe: 21 51.4 1.508 PL 57.67 PF 9.6 31 12.2 0.0 23.3 0.0 9.2 120 FTG 2T PE -0.3 Hi 12.9 5.5 13.4 20.0 0.127 TL 75.67 PV Pipe: 22 31.4 1.508 PL 11.08 PF 0.6 Hi 12.9 5.5 13.4 20.0 5.6 120 FTG ---- PE 0.0 H2 12.9 5.5 12.8 19.6 0.051 TL 11.08 PV Pipe: 23 11.9 1.508 PL 11.08 PF 0.1 H2 12.9 5.5 12.8 19.6 2.1 120 FTG ---- PE 0.0 H3 12.9 5.5 12.7 19.5 0.008 TL 11.08 PV Pipe: 24 -7.6 1.508 PL 11.08 PF 0.0 H3 12.9 5.5 12.7 19.5 1.4 120 FTG ---- PE 0.0 H4 12.9 5.5 12.8 19.5 0.004 TL 11.08 PV Pipe: 25 -27.2 1.508 PL 11.08 PF 0.4 H4 12.9 5.5 12.8 19.5 4.9 120 FTG ---- PE 0.0 H5 12.9 5.5 13.2 19.9 0.039 TL 11.08 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOE TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 26 -47.0 1.508 PL 57.58 PF 8.2 H5 12.9 5.5 13.2 19.9 8.5 120 FTG 2T PE 0.3 49 12.2 0.0 21.7 0.0 0.108 TL 75.58 PV Pipe: 27 52.3 1.508 PL 57.67 PF 10.0 32 12.2 0.0 24.1 0.0 9.4 120 FTG 2T PE -0.3 H6 12.9 5.5 13.8 20.3 0.132 TL 75.67 PV Pipe: 28 32.0 1.508 PL 11.08 PF 0.6 H6 12.9 5.5 13.8 20.3 5.7 120 FTG ---- PE 0.0 H7 12.9 5.5 13.2 19.9 0.053 TL 11.08 PV Pipe: 29 12.1 1.508 PL 11.08 PF 0.1 H7 12.9 5.5 13.2 19.9 2.2 120 FTG ---- PE 0.0 H8 12.9 5.5 13.1 19.8 0.009 TL 11.08 PV Pipe: 30 -7.7 1.508 PL 11.08 PF 0.0 H8 12.9 5.5 13.1 19.8 1.4 120 FTG ---- PE 0.0 H9 12.9 5.5 13.1 19.8 0.004 TL 11.08 PV Pipe: 31 -27.5 1.508 PL 11.08 PF 0.4 H9 12.9 5.5 13.1 19.8 4.9 120 FTG ---- PE 0.0 H10 12.9 5.5 13.6 20.2 0.040 TL 11.08 PV Pipe: 32 -47.7 1.508 PL 57.58 PF 8.4 H10 12.9 5.5 13.6 20.2 8.6 120 FTG 2T PE 0.3 50 12.2 0.0 22.3 0.0 0.111 TL 75.58 PV Pipe: 33 35.8 1.508 PL 57.67 PF. 3.8 33 12.2 0.0 26.7 0.0 6.4 120 FTG ---- PE -0.3 H11 12.9 5.5 22.7 26.0 0.065 TL 57.67 PV Pipe: 34 9.8 1.508 PL 11.08 PF 0.1 Hil 12.9 5.5 22.7 26.0 1.8 120 FTG ---- PE 0.0 H12 12.9 5.5 22.6 26.0 0.006 TL 11.08 PV Pipe: 35 -16.2 1.508 PL 90.83 PF 1.6 H12 12.9 5.5 22.6 26.0 2.9 120 FTG 2T PE 0.3 51 12.2 0.0 24.5 0.0 0.015 TL 108.83 PV Pipe: 36 6.3 1.508 PL 102.08 PF 0.3 34 12.2 0.0 30.3 0.0 1.1 120 FTG 2T2L PE -0.3 43 12.9 0.0 29.6 0.0 0.003 TL 126.08 PV Pipe: 37 20.5 1.508 PL 102.08 PF 3.0 35 12.2 0.0 33.4 0.0 3.7 120 FTG 3T PE -0.3 44 12.9 0.0 30.1 0.0 0.023 TL 129.08 PV Pipe: 38 24.3 1.508 PL 86.42 PF 3.4 37 12.2 0.0 33.8 0.0 4.4 120 FTG 2TF PE -0.3 45 12.9 0.0 30.1 0.0 0.032 TL 105.42 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 39 15.9 1.508 PL 126.08 PF 2.3 38 12.2 0.0 31.7 0.0 2.8 120 FTG 4T PE 0.0 55 12.2 0.0 29.4 0.0 0.014 TL 162.08 PV Pipe: 40 13.3 1.508 PL 126.08 PF 1.7 39 12.2 0.0 31.4 0.0 2.4 120 FTG 4T PE 0.0 56 12.2 0.0 29.7 0.0 0.010 TL 162.08 PV Pipe: 41 11.2 1.508 PL 126.08 PF 1.2 40 12.2 0.0 31.2 0.0 2.0 120 FTG 4T PE 0.0 57 12.2 0.0 29.9 0.0 0.008 TL 162.08 PV Pipe: 42 10.0 1.508 PL 126.08 PF 1.0 41 12.2 0.0 31.1 0.0 1.8 120 FTG 4T PE 0.0 58 12.2 0.0 30.1 0.0 0.006 TL 162.08 PV Pipe: 43 9.6 1.508 PL 129.33 PF 0.9 42 12.2 0.0 31.0 0.0 1.7 120 FTG 3T3L PE 0.0 59 12.2 0.0 30.1 0.0 0.006 TL 165.33 PV Pipe: 44 27.6 1.508 PL 25.17 PF 1.0 43 12.9 0.0 29.6 0.0 5.0 120 FTG ---- PE 0.0 46 12.9 0.0 28.6 0.0 0.040 TL 25.17 PV Pipe: 45 26.5 1.508 PL 33.96 PF 1.9 46 12.9 0.0 28.6 0.0 4.8 120 FTG 2T PE 0.3 52 12.2 0.0 27.0 0.0 0.037 TL 51.96 PV Pipe: 46 15.3 1.508 PL 32.33 PF 0.8 47 12.9 0.0 28.6 0.0 2.7 120 FTG 3T PE 0.3 53 12.2 0.0 28.1 0.0 0.014 TL 59.33 PV Pipe: 47 23.4 1.508 PL 25.17 PF 1.3 45 12.9 0.0 30.1 0.0 4.2 120 FTG 2T PE 0.0 48 12.9 0.0 28.8 0.0 0.030 TL 43.17 PV Pipe: 48 9.3 1.508 PL 32.33 PF 0.3 48 12.9 0.0 28.8 0.0 1.7 120 FTG 2T PE 0.3 54 12.2 0.0 28.8 0.0 0.005 TL 50.33 PV Pipe: 49 -21.3 1.508 PL 8.92 PF 0.4 43 12.9 0.0 29.6 0.0 3.8 120 FTG T PE 0.0 44 12.9 0.0 30.1 0.0 0.025 TL 17.92 PV Pipe: 50 -0.9 1.508 PL 6.67 PF 0.0 44 12.9 0.0 30.1 0.0 0.2 120 FTG T PE 0.0 45 12.9 0.0 30.1 0.0 0.000 TL 15.67 PV Pipe: 51 1.2 1.508 PL 8.92 PF 0.0 46 12.9 0.0 28.6 0.0 0.2 120 FTG T PE 0.0 47 12.9 0.0 28.6 0.0 0.000 TL 17.92 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 52 -14.1 1.508 PL 6.67 PF 0.2 47 12.9 0.0 28.6 0.0 2.5 120 FTG T PE 0.0 48 12.9 0.0 28.8 0.0 0.012 TL 15.67 PV Pipe: 53 -47.0 1.748 PL 11.75 PF 0.6 49 12.2 0.0 21.7 0.0 6.3. 120 FTG ---- PE 0.0 50 12.2 0.0 22.3 0.0 0.053 TL 11.75 PV Pipe: 54 -94.7 1.748 PL 11.75 PF 2.3 50 12.2 0.0 22.3 0.0 12.7 120 FTG ---- PE 0.0 51 12.2 0.0 24.5 0.0 0.192 TL 11.75 PV Pipe: 55 -111.0 1.748 PL 9.54 PF 2.5 51 12.2 0.0 24.5 0.0 14.8 120 FTG ---- PE 0.0 52 12.2 0.0 27.0 0.0 0.258 TL 9.54 PV Pipe: 56 -84.5 1.748 PL 7.29 PF 1.1 52 12.2 0.0 27.0 0.0 11.3 120 FTG ---- PE 0.0 53 12.2 0.0 28.1 0.0 0.156 TL 7.29 PV Pipe: 57 -69.2 1.748 PL 6.67 PF 0.7 53 12.2 0.0 28.1 0.0 9.2 120 FTG ---- PS 0.0 54 12.2 0.0 28.8 0.0 0.107 TL 6.67 PV Pipe: 58 -59.9 1.748 PL 6.54 PF 0.5 54 12.2 0.0 28.8 0.0 8.0 120 FTG ---- PE 0.0 55 12.2 0.0 29.4 0.0 0.082 TL 6.54 PV Pipe: 59 -44.0 1.748 PL 7.04 PF 0.3 55 12.2 0.0 29.4 0.0 5.9 120 FTG ---- PE 0.0 56 12.2 0.0 29.7 0.0 0.047 TL 7.04 PV Pipe: 60 -30.7 1.748 PL 9.42 PF 0.2 56 12.2 0.0 29.7 0.0 4.1 120 FTG ---- PE 0.0 57 12.2 0.0 29.9 0.0 0.024 TL 9.42 PV Pipe: 61 -19.5 1.748 PL 11.75 PF 0.1 57 12.2 0.0 29.9 0.0 2.6 120 FTG ---- PS 0.0 58 12.2 0.0 30.1 0.0 0.010 TL 11.75 PV Pipe: 62 -9.6 1.748 PL 11.75 PF 0.0 58 12.2 0.0 30.1 0.0 1.3 120 FTG ---- PE 0.0 59 12.2 0.0 30.1 0.0 0.003 TL 11.75 PV Pipe: 63 -51.4 1.748 PL 11.75 PF 0.7 31 12.2 0.0 23.3 0.0 6.9 120 FTG ---- PE 0.0 32 12.2 0.0 24.1 0.0 0.062 TL 11.75 PV Pipe: 64 -103.7 1.748 PL 11.75 PF 2.7 32 12.2 0.0 24.1 0.0 13.9 120 FTG ---- PE 0.0 33 12.2 0.0 26.7 0.0 0.227 TL 11.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF - JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 65 -139.5 1.748 PL 9.04 PF 3.6 33 12.2 0.0 26.7 0.0 18.7 120 FTG ---- PE 0.0 34 12.2 0.0 30.3 0.0 0.394 TL 9.04 PV Pipe: 66 -145.8 1.748 PL 7.29 PF 3.1 34 12.2 0.0 30.3 0.0 19.5 120 FTG ---- PE 0.0 35 12.2 0.0 33.4 0.0 0.427 TL 7.29 PV Pipe: 67 -166.3 1.748 PL 8.67 PF 4.7 35 12.2 0.0 33.4 0.0 22.2 120 FTG ---- PE 0.0 36 12.2 0.0 38.1 0.0 0.545 TL 8.67 PV Pipe: 68 84.2 1.748 PL 16.17 PF 4.4 36 12.2 0.0 38.1 0.0 11.3 120 FTG T PE 0.0 37 12.2 0.0 33.8 0.0 0.155 TL 28.17 PV Pipe: 69 59.9 1.748 PL 21.71 PF 2.0 37 12.2 0.0 33.8 0.0 8.0 120 FTG L PE 0.0 38 12.2 0.0 31.7 0.0 0.082 TL 24.71 PV Pipe: 70 44.0 1.748 PL 7.04 PF 0.3 38 12.2 0.0 31.7 0.0 5.9 120 FTG ---- PE 0.0 39 12.2 0.0 31.4 0.0 0.047 TL 7.04 PV Pipe: 71 30.7 1.748 PL 9.42 PF 0.2 39 12.2 0.0 31.4 0.0 4.1 120 FTG ---- PE 0.0 40 12.2 0.0 31.2 0.0 0.024 TL 9.42 PV Pipe: 72 19.5 1.748 PL 11.75 PF 0.1 40 12.2 0.0 31.2 0.0 2.6 120 FTG ---- PE 0.0 41 12.2 0.0 31.1 0.0 0.010 TL 11.75 PV Pipe: 73 9.6 1.748 PL 8.50 PF 0.0 41 12.2 0.0 31.1 0.0 1.3 120 FTG ---- PE 0.0 42 12.2 0.0 31.0 0.0 0.003 TL 8.50 PV Pipe: 74 -250.5 2.223 PL 52.67 PF 25.5 36 12.2 0.0 38.1 0.0 20.7 120 FTG T2F PE 0.0 22 12.2 0.0 63.6 0.0 0.360 TL 70.67 PV Pipe: 75 25.2 2.223 PL 8.50 PF 0.0 19 12.2 0.0 64.0 0.0 2.1 120 FTG ---- PE 0.0 20 12.2 0.0 64.0 0.0 0.005 TL 8.50 PV Pipe: 76 51.0 2.223 PL 11.75 PF 0.2 20 12.2 0.0 64.0 0.0 4.2 120 FTG ---- PE 0.0 21 12.2 0.0 63.8 0.0 0.019 TL 11.75 PV Pipe: 77 77.9 2.223 PL 3.92 PF 0.2 21 12.2 0.0 63.8 0.0 6.4 120 FTG ---- PE 0.0 22 12.2 0.0 63.6 0.0 0.042 TL 3.92 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 78 -172.6 2.223 PL 5.50 PF 1.0 22 12.2 0.0 63.6 0.0 14.3 120 FTG ---- PE 0.0 23 12.2 0.0 64.6 0.0 0.181 TL 5.50 PV Pipe: 79 -146.2 2.223 FL 7.04 PF 0.9 23 12.2 0.0 64.6 0.0 12.1 120 FTG ---- FE 0.0 24 12.2 0.0 65.5 0.0 0.133 TL 7.04 PV Pipe: 80 -121.0 2.223 FL 17.54 PF 2.4 24 12.2 0.0 65.5 0.0 10.0 120 FTG 2L PE 0.0 25 12.2 0.0 67.9 0.0 0.094 TL 25.54 PV Pipe: 81 -99.8 2.223 FL 6.67 PF 0.4 25 12.2 0.0 67.9 0.0 8.2 120 FTG ---- PE 0.0 26 12.2 0.0 68.4 0.0 0.066 TL 6.67 PV Pipe: 82 -81.6 2.223 PL 29.79 PF 1.7 26 12.2 0.0 68.4 0.0 6.7 120 FTG 2L PE 0.0 27 12.2 0.0 70.1 0.0 0.045 TL 37.79 PV Pipe: 83 -74.5 2.223 FL 9.54 PF 0.4 27 12.2 0.0 70.1 0.0 6.2 120 FTG ---- PE 0.0 28 12.2 0.0 70.4 0.0 0.038 TL 9.54 PV Pipe: 84 -49.0 2.223 PL 11.75 PF 0.2 28 12.2 0.0 70.4 0.0 4.1 120 FTG ---- PE 0.0 29 12.2 0.0 70.6 0.0 0.018 TL 11.75 PV Pipe: 85 -24.4 2.223 PL 11.75 PF 0.1 29 12.2 0.0 70.6 0.0 2.0 120 FTG ---- PE 0.0 30 12.2 0.0 70.7 0.0 0.005 TL 11.75 PV Pipe: 86 -25.2 2.223 PL 11.75 PF 0.1 1 12.2 0.0 69.3 0.0 2.1 120 FTG ---- PE 0.0 2 12.2 0.0 69.4 0.0 0.005 TL 11.75 PV Pipe: 87 -51.0 2.223 PL 11.75 PF 0.2 2 12.2 0.0 69.4 0.0 4.2 120 FTG ---- PE 0.0 3 12.2 0.0 69.6 0.0 0.019 TL 11.75 PV Pipe: 88 -77.9 2.223 PL 9.42 PF 0.4 3 12.2 0.0 69.6 0.0 6.4 120 FTG ---- FE 0.0 4 12.2 0.0 70.0 0.0 0.042 TL 9.42 PV Pipe: 89 -104.3 2.223 PL 7.04 PF 0.5 4 12.2 0.0 70.0 0.0 8.6 120 FTG ---- PE 0.0 5 12.2 0.0 70.5 0.0 0.071 TL 7.04 PV Pipe: 90 -129.5 2.223 PL 6.04 PF 0.6 5 12.2 0.0 70.5 0.0 10.7 120 FTG ---- PE 0.0 6 12.2 0.0 71.1 0.0 0.106 TL 6.04 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 2/15/2006 C:\DATA\CONPALFORUM15TF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 91 -130.2 2.223 PL 6.67 PF 0.7 6 12.2 0.0 71.1 0.0 10.8 120 FTG ---- PE 0.0 7 12.2 0.0 71.9 0.0 0.107 TL 6.67 PV Pipe: 92 -140.7 2.223 PL 7.29 PF 2.6 7 12.2 0.0 71.9 0.0 11.6 120 FTG T PE 0.0 8 12.2 0.0 74.5 0.0 0.124 TL 21.29 PV Pipe: 93 -176.0 2.223 PL 0.62 PF 2.7 8 12.2 0.0 74.5 0.0 14.5 120 FTG T PE 0.0 9 12.2 0.0 77.2 0.0 0.188 TL 14.62 PV Pipe: 94 74.5 2.223 PL 8.92 PF 0.3 9 12.2 0.0 77.2 0.0 6.2 120 FTG ---- PE 0.0 10 12.2 0.0 76.9 0.0 0.038 TL 8.92 PV Pipe: 95 49.0 2.223 PL 11.75 PF 0.2 10 12.2 0.0 76.9 0.0 4.1 120 FTG ---- PE 0.0 11 12.2 0.0 76.7 0.0 0.018 TL 11.75 PV Pipe: 96 24.4 2.223 PL 11.75 PF 0.1 11 12.2 0.0 76.7 0.0 2.0 120 FTG ---- PE 0.0 12 12.2 0.0 76.6 0.0 0.005 TL 11.75 PV Pipe: 97 -250.5 2.723 PL 20.25 PF 5.3 9 12.2 0.0 77.2 0.0 13.8 120 FTG T PE 0.0 TOR 12.2 0.0 82.5 0.0 0.134 TL 39.25 PV Pipe: 98 -250.5 2.723 PL 10.17 PF 1.4 TOR 12.2 0.0 82.5 0.0 13.8 120 FTG ---- PE 4.4 60 2.0 0.0 88.3 0.0 0.134 TL 10.17 PV Pipe: 99 -250.5 4.328 PL 5.00 PF 0.3 60 2.0 0.0 88.3 0.0 5.5 120 FTG. 2L PE 0.9 BOR 0.0 H.S. 89.5 100.0 0.014 TL 23.00 PV Pipe: 100 -350.5 6.134 PL 151.00 PF 0.6 BOR 0.0 H.S. 89.5 100.0 3.8 150 FTG 5LG PE 0.0 Ui 0.0 0.0 90.1 0.0 0.003 TL 199.00 PV Pipe: 101 FIXED PRESSURE LOSS DEVICE U2 0.0 0.0 93.6 0.0 3.5 psi, 350.5 gpm Ui 0.0 0.0 90.1 0.0 Pipe: 102 -350.5 6.134 PL 10.00 PF 0.2 U2 0.0 0.0 93.6 0.0 3.8 150 FTG T2LG PE 2.6 U3 -6.0 SRCE 96.4 (N/A) 0.003 TL 61.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 2/15/2006 C:\DATA\CONPALFORUM15TF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 NOTES: (1) Calculations were performed by the HASS 7.7 computer program under license no. 38010408 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.064 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 22.2 ft/sec at pipe 67. (4) a. System remote area HAS been proven or 'peaked' Minimum pressure at any sprinkler: 12.709 psi Minimum pressure with remote area shifted one sprinkler space toward left cross main: 12.731 psi Minimum pressure with remote area shifted one sprinkler space toward right cross main: 12.711 psi (5) PIPE FITTINGS TABLE Pipe Table Name: LINDLEY.PIP PAGE: B MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) B T L C B G N F Eli Tee LngEil ChkVlv BfyViv GatVlv NPTee 45 6.134 21.00 30.00 9.00 32.00 15.00 3.00 30.00 7.00 PAGE: J MATERIAL: LINDLE HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll --------------------------------------------------------ChkVlv BfyViv GatVlv AlmChk DPVlv NPTee 45 1.508 5.00 9.00 3.00 12.00 12.00 2.00 20.00 17.00 7.00 1.00 1.748 6.00 12.00 3.00 14.00 11.00 2.00 18.00 15.00 10.00 2.00 2.223 7.00 14.00 4.00 15.00 10.00 1.00 17.00 14.00 12.00 2 .00 2.723 10.00 19.00 6.00 22.00 16.00 2.00 22.00 16.00 17.00 3.00 4.328 14.00 28.00 9.00 31.00 22.00 4.00 35.00 14.00 26.00 4.00 o U) S I-I '-3 N.) WATER SUPPLY ANALYSIS Static: 109.80 psi Resid: 104.40 psi Flow: 1500.0 gpm LEGEND Available pressure 109.09 psi @ 500.5 gpm Required pressure 96.39 psi @ 500.5 gpm Source Supply Curve System Demand Curve 120.0 100. 0 G A U G E 80.0 P R E S S 60.0 U R E 40.0 p S i 20.0 0.0 —14 .7 400 600 800 1000 1200 1400 1600 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF - JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 WATER SUPPLY CURVE 120+ I \\\\\\\\\\\\\\\\\\\ * <-104.4 psi @ 1500 gpm Flow Test Point 100+ x 90+ P 80+ R I E S I S 70+ U I R I E I 60+ P I S I I 50+ 40+ 30+ 20+ LEGEND 'I I, I X = Required Water Supply I 96.39 psi @ 500.5 gpm 10+ 0 = Available Water Supply I 109.09 psi @ 500.5 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14 DATE: 2/15/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 Utility Report: Equivalent K-Factor Calculator Node Sprinkler Pres. Dia. Pipe Ftgs. Total H -W Equivalent Name K-Factor (psi) (in) ----------------------------------------------------------------------- Len. (ft) Len. (ft) coef. K-factor ANY 5.60 7.00 1.080 0.33 T 5.33 120.00 5.47 LINDLEY FIRE PROTECTION Co. 2220 E. VIA BURTON ANAHEIM, CA 714-535-5761 HYDRAULIC CALCULATIONS FOR CONCOURSE ONE @ THE PALOMAR FORUM 3207 GRAYHAWK COURT CARLSBAD, CA SECOND FLOOR DATE: 02-16-06 -DESIGN DATA- SYSTEM DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (INCLUDING HOSE) FLOW AND PRESSURE & BASE OF RISER: SPRINKLER ORIFICE SIZE: CONTRACTOR CERTIFICATION NUMBER: .15 GPM/SQ. FT. 1500 SQ. FT. 125 SQ. FT. 12 SPRINKLERS 240.2 GPM 490.2 GPM 240.2 GPM @ 89.6 PSI ½" C16/C34NO. 713562 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 WATER SUPPLY DATA - SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) U3 109.8 104.4 1500.0 109.1 490.2 96.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 490.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 150.0 GPM OTHER HOSE STREAM ALLOWANCES 100.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 240.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Hi 28.3 K= 5.47 12.4 19.2 H2 28.3 K= 5.47 11.9 18.9 H3 28.3 K= 5.47 11.8 18.8 H4 28.3 K= 5.47 11.9 18.8 H5 28.3 K= 5.47 12.3 19.2 H6 28.3 K= 5.47 12.8 19.5 H7 28.3 K= 5.47 12.3 19.2 H8 28.3 K= 5.47 12.2 19.1 H9 28.3 K= 5.47 12.3 19.1 H10 28.3 K= 5.47 12.7 19.5 H1i 28.3 K= 5.47 20.0 24.4 H12 28.3 K= 5.47 19.9 24.4 1 28.3 - - - - 68.3 - - - 2 28.3 - - - - 68.3 - - - 3 28.3 - - - - 68.5 - - - 4 28.3 - - - - 68.8 - - - 5 28.3 - - - - 68.3 - - - 6 28.3 - - - - 66.7 - - - 7 28.3 - - - - 65.7 - - - 8 28.3 - - - - 65.1 - - - 9 28.3 - - - - 64.8 - - - 10 28.3 - - - - 64.7 - - - 11 28.3 - - - - 66.8 - - - 12 28.3 - - - - 66.5 - - - 13 28.3 - - - - 63.4 - - - 14 28.3 - - - - 63.4 - - - 15 28.3 - - - - 63.2 - - - 16 28.3 - - - - 62.8 - - - 17 28.3 - - - - 59.9 - - 18 28.3 - - - - 58.8 - - - 19 28.3 - - - - 57.8 - - - 20 28.3 - - - - 58.0 - - - 21 28.3 - - - - 58.3 - - - 22 28.3 - - - - 58.3 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 23 28.3 - - - - 29.9 - - - 24 28.3 - - - - 29.9 - - - 25 28.3 - - - - 30.2 - - - 26 28.3 - - - - 30.7 - - - 27 28.3 - - - - 35.2 - - - 28 28.3 - - - - 33.2 - - - 29 28.3 - - - - 28.0 - - - 30 28.3 - - - - 24.0 - - - 31 28.3 - - - - 21.6 - - - 32 28.3 - - - - 21.0 - - - 33 28.3 - - - - 25.5 - - - 34 28.3 - - - - 25.3 - - - 35 28.3 - - - - 28.3 - - - 36 28.3 - - - - 28.3 - - - 37 28.3 - - - - 28.1 - - - 38 28.3 - - - - 27.5 - - - 39 28.3 - - - - 26.4 - - - 40 28.3 - - - - 24.3 - - - 41 28.3 - - - - 21.4 - - - 42 28.3 - - - - 19.1 - - - 43 28.3 - - - - 18.5 - - - 60 2.0 - - - - 88.5 - - - TOR-ROOF 28.3 - - - - 70.9 - - - TOR-1STF 12.2 - - - - 82.8 - - - BOR 0.0 HOSE STREAM 89.6 100.0 Ui 0.0 - - - - 90.2 - - - U2 0.0 - - - - 93.7 - - - U3 -6.0 SOURCE 96.5 340.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 22.4 1.508 PL 159.33 PF 4.8 1 28.3 0.0 68.3 0.0 4.0 120 FTG 2T PE 0.0 13 28.3 0.0 63.4 0.0 0.027 TL 177.33 PV Pipe: 2 22.6 1.508 PL 159.33 PF 4.9 2 28.3 0.0 68.3 0.0 4.1 120 FTG 2T PE 0.0 14 28.3 0.0 63.4 0.0 0.028 TL 177.33 PV Pipe: 3 23.5 1.508 PL 159.33 PF 5.3 3 28.3 0.0 68.5 0.0 4.2 120 FTG 2T PE 0.0 15 28.3 0.0 63.2 0.0 0.030 TL 177.33 PV Pipe: 4 23.6 1.508 PL 31.33 PF 1.5 5 28.3 0.0 68.3 0.0 4.2 120 FTG 2T PE 0.0 11 28.3 0.0 66.8 0.0 0.030 TL 49.33 PV Pipe: 5 30.1 1.508 PL 126.83 PF 6.8 6 28.3 0.0 66.7 0.0 5.4 120 FTG 2T PE 0.0 17 28.3 0.0 59.9 0.0 0.047 TL 144.83 PV Pipe: 6 30.2 1.508 PL 126.83 PF 6.9 7 28.3 0.0 65.7 0.0 5.4 120 FTG 2T PE 0.0 18 28.3 0.0 58.8 0.0 0.048 TL 144.83 PV Pipe: 7 30.6 1.508 PL 126.83 PF 7.0 8 28.3 0.0 65.1 0.0 5.5 120 FTG 2T PE 0.0 20 28.3 0.0 58.0 0.0 0.049 TL 144.83 PV Pipe: 8 29.2 1.508 PL 126.83 PF 6.5 9 28.3 0.0 64.8 0.0 5.3 120 FTG 2T PE 0.0 21 28.3 0.0 58.3 0.0 0.045 TL 144.83 PV Pipe: 9 28.0 1.508 PL 130.08 PF 6.4 10 28.3 0.0 64.7 0.0 5.0 120 FTG 2T2L PE 0.0 22 28.3 0.0 58.3 0.0 0.041 TL 154.08 PV Pipe: 10 11.9 1.508 PL 28.33 PF 0.3 11 28.3 0.0 66.8 0.0 2.1 120 FTG 2L PE 0.0 12 28.3 0.0 66.5 0.0 0.009 TL 34.33 PV Pipe: 11 23.6 1.508 PL 103.83 PF 3.7 12 28.3 0.0 66.5 0.0 4.2 120 FTG 2T PE 0.0 16 28.3 0.0 62.8 0.0 0.030 TL 121.83 PV Pipe: 12 11.7 1.508 PL 29.33 PF 0.3 11 28.3 0.0 66.8 0.0 2.1 120 FTG 2L PE 0.0 12 28.3 0.0 66.5 0.0 0.008 TL 35.33 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 13.4 1.508 FL 122.83 PF 1.5 23 28.3 0.0 29.9 0.0 2.4 120 FTG 2T2L PE 0.0 35 28.3 0.0 28.3 0.0 0.011 TL 146.83 PV Pipe: 14 14.3 1.508 PL 119.58 PF 1.6 24 28.3 0.0 29.9 0.0 2.6 120 FTG 2T FE 0.0 36 28.3 0.0 28.3 0.0 0.012 TL 137.58 PV Pipe: 15 16.4 1.508 PL 119.58 PF 2.1 25 28.3 0.0 30.2 0.0 2.9 120 FTG 2T FE 0.0 37 28.3 0.0 28.1 0.0 0.015 TL 137.58 PV Pipe: 16 20.5 1.508 PL 119.58 PF 3.2 26 28.3 0.0 30.7 0.0 3.7 120 FTG 2T FE 0.0 38 28.3 0.0 27.5 0.0 0.023 TL 137.58 PV Pipe: 17 26.8 1.508 FL 159.33 PF 6.8 28 28.3 0.0 33.2 0.0 4.8 120 FTG 2T FE 0.0 39 28.3 0.0 26.4 0.0 0.038 TL 177.33 PV Pipe: 18 19.1 1.508 FL 103.50 PF 2.5 29 28.3 0.0 28.0 0.0 3.4 120 FTG 2T FE 0.0 33 28.3 0.0 25.5 0.0 0.020 TL 121.50 Pv. Pipe: 19 9.4 1.508 PL 30.50 PF 0.2 33 28.3 0.0 25.5 0.0 1.7 120 FTG 2L FE 0.0 34 28.3 0.0 25.3 0.0 0.006 TL 36.50 PV Pipe: 20 9.7 1.508 FL 28.50 PF 0.2 33 28.3 0.0 25.5 0.0 1.7 120 FTG 2L FE 0.0 34 28.3 0.0 25.3 0.0 0.006 TL 34.50 PV Pipe: 21 19.1 1.508 FL 31.33 PF 1.0 34 28.3 0.0 25.3 0.0 3.4 120 FTG 2T FE 0.0 40 28.3 0.0 24.3. 0.0 0.020 TL 49.33 PV Pipe: 22 32.2 1.508 FL 66.58 PF 4.0 30 28.3 0.0 24.0 0.0 5.8 120 FTG T FE 0.0 Hil 28.3 5.5 20.0 24.4 0.053 TL 75.58 PV Pipe: 23 7.7 1.508 FL 10.67 PF 0.1 Hil 28.3 5.5 20.0 24.4 1.4 120 FTG T FE 0.0 H12 28.3 5.5 19.9 24.4 0.004 TL 19.67 PV Pipe: 24 -16.7 1.508 FL 82.42 PF 1.5 H12 28.3 5.5 19.9 24.4 3.0 120 FTG T FE 0.0 41 28.3 0.0 21.4 0.0 0.016 TL 91.42 PV Pipe: 25 49.2 1.508 FL 66.58 PF 8.9 31 28.3 0.0 21.6 0.0 8.8 120 FTG T FE 0.0 H6 28.3 5.5 12.8 19.5 0.117 TL 75.58 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF JOE TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 26 29.6 1.508 PL 10.67 PF 0.5 H6 28.3 5.5 12.8 19.5 5.3 120 FTC ---- PE 0.0 H7 28.3 5.5 12.3 19.2 0.046 TL 10.67 PV Pipe: 27 10.5 1.508 PL 10.67 PF 0.1 H7 28.3 5.5 12.3 19.2 1.9 .120 FTG ---- PE 0.0 H8 28.3 5.5 12.2 19.1 0.007 TL 10.67 PV Pipe: 28 -8.7 1.508 PL 10.67 PF 0.1 H8 28.3 5.5 12.2 19.1 1.6 120 FTG ---- PE 0.0 H9 28.3 5.5 12.3 19.1 0.005 TL 10.67 PV Pipe: 29 -27.8 1.508 PL 10.67 PF 0.4 H9 28.3 5.5 12.3 19.1 5.0 120 FTG ---- PE 0.0 H10 28.3 5.5 12.7 19.5 0.041 TL 10.67 PV Pipe: 30 -47.3 1.508 PL 50.08 PF 6.4 H10 28.3 5.5 12.7 19.5 8.5 120 FTG T PE 0.0 42 28.3 0.0 19.1 0.0 0.109 TL 59.08 PV Pipe: 31 48.4 1.508 PL 66.58 PF 8.6 32 28.3 0.0 21.0 0.0 8.7 120 FTG T PE 0.0 Hi 28.3 5.5 12.4 19.2 0.114 TL 75.58 PV Pipe: 32 29.2 1.508 PL 10.67 PF 0.5 Hi 28.3 5.5 12.4 19.2 5.2 120 FTG ---- PE 0.0 H2 28.3 5.5 11.9 18.9 0.045 TL 10.67 PV Pipe: 33 10.3 1.508 PL 10.67 PF 0.1 H2 28.3 5.5 11.9 18.9 1.9 120 FTG ---- PE 0.0 H3 28.3 5.5 11.8 18.8 0.007 TL 10.67 PV Pipe: 34 -8.5 1.508 PL 10.67 PF 0.0 H3 28.3 5.5 11.8 18.8 1.5 120 FTG ---- PE 0.0 H4 28.3 5.5 11.9 18.8 0.005 TL 10.67 PV Pipe: 35 -27.3 1.508 PL 10.67 PF 0.4 H4 28.3 5.5 11.9 18.8 4.9 120 FTG ---- PE 0.0 H5 28.3 5.5 12.3 19.2 0.040 TL 10.67 PV Pipe: 36 -46.5 1.508 PL 50.08 PF 6.2 H5 28.3 5.5 12.3 19.2 8.3 120 FTG T PE 0.0 43 28.3 0.0 18.5 0.0 0.106 TL 59.08 PV Pipe: 37 13.4 1.748 PL 11.75 PF 0.1 35 28.3 0.0 28.3 0.0 1.8 120 FTG ---- PE 0.0 36 28.3 0.0 28.3 0.0 0.005 TL 11.75 PV Pipe: 38 27.7 1.748 PL 11.75 PF 0.2 36 28.3 0.0 28.3 0.0 3.7 120 FTG ---- PE 0.0 37 28.3 0.0 28.1 0.0 0.020 TL 11.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 39 44.1 1.748 PL 11.67 PF 0.5 37 28.3 0.0 28.1 0.0 5.9 120 FTG ---- PE 0.0 38 28.3 0.0 27.5 0.0 0.047 TL 11.67 PV Pipe: 40 64.6 1.748 PL 11.58 PF 1.1 38 28.3 0.0 27.5 0.0 8.6 120 FTG ---- PE 0.0 39 28.3 0.0 26.4 0.0 0.095 TL 11.58 PV Pipe: 41 91.3 1.748 PL 11.58 PF 2.1 39 28.3 0.0 26.4 0.0 12.2 120 FTG ---- PE 0.0 40 28.3 0.0 24.3 0.0 0.180 TL 11.58 PV Pipe: 42 110.5 1.748 PL 11.67 PF 3.0 40 28.3 0.0 24.3 0.0 14.8 120 FTG ---- PE 0.0 41 28.3 0.0 21.4 0.0 0.255 TL 11.67 PV Pipe: 43 93.8 1.748 PL 11.75 PF 2.2 41 28.3 0.0 21.4 0.0 12.5 120 FTG ---- PE 0.0 42 28.3 0.0 19.1 0.0 0.189 TL 11.75 PV Pipe: 44 46.5 1.748 PL 11.75 PE 0.6 42 28.3 0.0 19.1 0.0 6.2 120 FTG ---- PE 0.0 43 28.3 0.0 18.5 0.0 0.052 TL 11.75 PV Pipe: 45 -13.4 1.748 PL 8.00 PF 0.0 23 28.3 0.0 29.9 0.0 1.8 120 FTG ---- PE 0.0 24 28.3 0.0 29.9 0.0 0.005 TL 8.00 PV Pipe: 46 -27.7 1.748 PL 11.75 PF 0.2 24 28.3 0.0 29.9 0.0 3.7 120 FTG ---- PE 0.0 25 28.3 0.0 30.2 0.0 0.020 TL 11.75 PV Pipe: 47 -44.1 1.748 PL 11.67 PF 0.5 25 28.3 0.0 30.2 0.0 5.9 120 FTG ---- PE 0.0 26 28.3 0.0 30.7 0.0 0.047 TL 11.67 PV Pipe: 48 -64.6 1.748 PL 47.17 PF 4.5 26 28.3 0.0 30.7 0.0 8.6 120 FTG ---- PE 0.0 27 28.3 0.0 35.2 0.0 0.095 TL 47.17 PV Pipe: 49 175.6 1.748 PL 3.33 PF 2.0 27 28.3 0.0 35.2 0.0 23.5 120 FTG ---- PE 0.0 28 28.3 0.0 33.2 0.0 0.602 TL 3.33 PV Pipe: 50 148.9 1.748 PL 11.58 PF 5.1 28 28.3 0.0 33.2 0.0 19.9 120 FTG ---- PE 0.0 29 28.3 0.0 28.0 0.0 0.444 TL 11.58 PV Pipe: 51 129.7 1.748 PL 11.67 PF 4.0 29 28.3 0.0 28.0 0.0 17.3 120 FTG ---- PE 0.0 30 28.3 0.0 24.0 0.0 0.344 TL 11.67 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF - JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 52 97.6 1.748 PL 11.75 PF 2.4 30 28.3 0.0 24.0 0.0 13.0 120 FTG ---- PE 0.0 31 28.3 0.0 21.6 0.0 0.203 TL 11.75 PV Pipe: 53 48.4 1.748 PL 11.75 PF 0.7 31 28.3 0.0 21.6 0.0 6.5 120 FTG ---- PE 0.0 32 28.3 0.0 21.0 0.0 0.056 TL 11.75 PV Pipe: 54 -240.2 2.223 FL 49.75 PF 22.6 27 28.3 0.0 35.2 0.0 19.9 120 FTG T2F PE 0.0 19 28.3 0.0 57.8 0.0 0.333 TL 67.75 PV Pipe: 55 22.4 2.223 PL 11.75 PF 0.0 13 28.3 0.0 63.4 0.0 1.8 120 FTG ---- PE 0.0 14 28.3 0.0 63.4 0.0 0.004 TL 11.75 PV Pipe: 56 45.0 2.223 FL 11.75 PF 0.2 14 28.3 0.0 63.4 0.0 3.7 120 FTG ---- PE 0.0 15 28.3 0.0 63.2 0.0 0.015 TL 11.75 PV Pipe: 57 68.4 2.223 PL 11.67 PF 0.4 15 28.3 0.0 63.2 0.0 5.7 120 FTG ---- PE 0.0 16 28.3 0.0 62.8 0.0 0.033 TL 11.67 PV Pipe: 58 92.1 2.223 PL 44.25 PF 3.0 16 28.3 0.0 62.8 0.0 7.6 120 FTG 2L FE 0.0 17 28.3 0.0 59.9 0.0 0.057 TL 52.25 PV Pipe: 59 122.1 2.223 FL 11.58 PF 1.1 17 28.3 0.0 59.9 0.0 10.1 120 FTG ---- FE 0.0 18 28.3 0.0 58.8 0.0 0.095 TL 11.58 PV Pipe: 60 152.4 2.223 FL 6.92 PF 1.0 18 28.3 0.0 58.8 0.0 12.6 120 FTG ---- FE 0.0 19 28.3 0.0 57.8 0.0 0.144 TL 6.92 PV Pipe: 61 -87.8 2.223 FL 4.92 PF 0.3 19 28.3 0.0 57.8 0.0 7.3 120 FTG ---- FE 0.0 20 28.3 0.0 58.0 0.0 0.052 TL 4.92 PV Pipe: 62 -57.2 2.223 FL 11.75 PF 0.3 20 28.3 0.0 58.0 0.0 4.7 120 FTG ---- PE 0.0 21 28.3 0.0 58.3 0.0 0.023 TL 11.75 PV Pipe: 63 -28.0 2.223 PL 8.00 PF 0.0 21 28.3 0.0 58.3 0.0 2.3 120 FTG ---- PE 0.0 22 28.3 0.0 58.3 0.0 0.006 TL 8.00 PV Pipe: 64 -22.4 2.223 FL 11.75 PF 0.0 1 28.3 0.0 68.3 0.0 1.8 120 FTC ---- FE 0.0 2 28.3 0.0 68.3 0.0 0.004 TL 11.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF - JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 - PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 65 -45.0 2.223 PL 11.75 PF 0.2 2 28.3 0.0 68.3 0.0 3.7 120 FTG ---- PE 0.0 3 28.3 0.0 68.5 0.0 0.015 TL 11.75 PV Pipe: 66 -68.4 2.223 PL 8.92 PF 0.3 3 28.3 0.0 68.5 0.0 5.7 120 FTG ---- PE 0.0 4 28.3 0.0 68.8 0.0 0.033 TL 8.92 PV Pipe: 67 171.8 2.223 PL 2.75 PF 0.5 4 28.3 0.0 68.8 0.0 14.2 120 FTG ---- PE 0.0 5 28.3 0.0 68.3 0.0 0.179 TL 2.75 PV Pipe: 68 148.1 2.223 PL 11.58 PF 1.6 5 28.3 0.0 68.3 0.0 12.2 120 FTG ---- PE 0.0 6 28.3 0.0 66.7 0.0 0.136 TL 11.58 PV Pipe: 69 118.0 2.223 PL 11.58 PF 1.0 6 28.3 0.0 66.7 0.0 9.8 120 FTG ---- PE 0.0 7 28.3 0.0 65.7 0.0 0.090 TL 11.58 PV Pipe: 70 87.8 2.223 PL 11.67 PF 0.6 7 28.3 0.0 65.7 0.0 7.3 120 FTG ---- FE 0.0 8 28.3 0.0 65.1 0.0 0.052 TL 11.67 PV Pipe: 71 57.2 2.223 PL 11.75 PF 0.3 8 28.3 0.0 65.1 0.0 4.7 120 FTG ---- PE 0.0 9 28.3 0.0. 64.8 0.0 0.023 TL 11.75 PV Pipe: 72 28.0 2.223 PL 11.75 PF 0.1 9 28.3 0.0 64.8 0.0 2.3 120 FTG ---- PE 0.0 10 28.3 0.0 64.7 0.0 0.006 TL 11.75 PV Pipe: 73 -240.2 2.723 PL 11.08 PF 2.1 4 28.3 0.0 68.8 0.0 13.2 120 FTG L PE 0.0 TOR -ROOF 28.3 0.0 70.9 0.0 0.124 TL 17.08 PV Pipe: 74 -240.2 2.723 FL 14.67 PF 4.9 TOR -ROOF 28.3 0.0 70.9 0.0 13.2 120 FTG TL FE 7.0 TOR-1STF 12.2 0.0 82.8 0.0 0.124 TL 39.67 PV Pipe: 75 -240.2 2.723 FL 10.17 PF 1.3 TOR-1STF 12.2 0.0 82.8 0.0 13.2 120 FTG ---- PE 4.4 60 2.0 0.0 88.5 0.0 0.124 TL 10.17 PV Pipe: 76 -240.2 4.328 FL 5.00 PF 0.3 60 2.0 0.0 88.5 0.0 5.2 120 FTG 2L FE 0.9 BOR 0.0 H.S. 89.6 100.0 0.013 TL 23.00 PV Pipe: 77 -340.2 6.134 FL 151.00 PF 0.6 BOR 0.0 H.S. 89.6 100.0 3.7 150 FTG 5LG FE 0.0 Ui 0.0 0.0 90.2 0.0 0.003 TL 199.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF - JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 78 FIXED PRESSURE LOSS DEVICE U2 0.0 0.0 93.7 0.0 3.5 psi, 340.2 gpm Ui 0.0 0.0 90.2 0.0 Pipe: 79 -340.2 6.134 PL 10.00 PP 0.2 U2 0.0 0.0 93.7 0.0 3.7 150 FTG T2LG PE 2.6 U3 -6.0 SRCE 96.5 (N/A) 0.003 TL 61.00 PV NOTES: (1) Calculations were performed by the HASS 7.7 computer program under license no. 38010408 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.086 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 23.5 ft/sec at pipe 49. (4) a. System remote area HAS been proven or 'peaked' Minimum pressure at any sprinkler: 11.812 psi Minimum pressure with remote area shifted one sprinkler space toward left cross main: 11.818 psi Minimum pressure with remote area shifted one sprinkler space toward right cross main: 11.831 psi (5) PIPE FITTINGS TABLE Pipe Table Name: LINDLEY.PIP PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N F Eli Tee LngEll ChkVlv BfyVlv GatVlv NPTee 45 6.134 21.00 30.00 9.00 32.00 15.00 3.00 30.00 7.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PAGE: J MATERIAL: LINDLE HWC: 120 - Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll --------------------------------------------------------ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 45 1.508 5.00 9.00 3.00 12.00 12.00 2.00 20.00 17.00 7.00 1.00 1.748 6.00 12.00 3.00 14.00 11.00 2.00 18.00 15.00 10.00 2.00 2.223 7.00 14.00 4.00 15.00 10.00 1.00 17.00 14.00 12.00 2.00 2.723 10.00 19.00 6.00 22.00 16.00 2.00 22.00 16.00 17.00 3.00 4.328 14.00 28.00 9.00 31.00 22.00 4.00 35.00 14.00 26.00 4.00 120 .0 20.0 0.0 -14. WATER SUPPLY ANALYSIS Static: 109.80 psi Resid: 104.40 psi Flow: 1500.0 gpm LEGEND Available pressure 109.12 psi @ 490.2 gpm Required pressure 96.53 psi 8 490.2 gpm Source Supply Curve System Demand Curve 100. 0 G U G Arme P R E S S 60.0 U R E 40.0 p S i 400 600 800 1000 1200 1400 1600 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 WATER SUPPLY CURVE 120+ 110*\\\\0\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\\ I * <-104.4 psi @ 1500 gpm I Flow Test Point 100+ x 90+ P 80+ R I E I S I 5 70+ U R I E 60+ P S I I 50+ ) I 40+ 30+ 20+ LEGEND I X = Required Water Supply I 96.53 psi @ 490.2 gpm 10+ I 0 = Available Water Supply I 109.12 psi @ 490.2 gpm I U 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 2/16/2006 C:\DATA\CONPALFORM2NDFx.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 Utility Report: Equivalent K-Factor Calculator Node Sprinkler Pres. Dia. Pipe Ftgs. Total H-W Equivalent Name K-Factor (psi) (in) ----------------------------------------------------------------------- Len. (ft) Len. (ft) coef. K-factor ANY 5.60 7.00 1.080 0.33 T 5.33 120.00 5.47 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 WATER SUPPLY DATA SOURCE STATIC RESID. FLOW NODE PRESS. PRESS. @ TAG (PSI) (PSI) (GPM) U3 109.8 104.4 1500.0 AGGREGATE FLOW ANALYSIS: AVAIL. TOTAL REQ'D PRESS. @ DEMAND PRESS. (PSI) (GPM) (PSI) 109.1 500.4 96 G .4 TOTAL FLOW AT SOURCE 500.4 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 150.0 GPM OTHER HOSE STREAM ALLOWANCES 100.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 250.4 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Hi 12.9 K= 5.45 13.5 20.0 H2 12.9 K= 5.45 12.9 19.6 H3 12.9 K= 5.45 12.8 19.5 H4 12.9 K= 5.45 12.8 19.5 H5 12.9 K= 5.45 13.3 19.9 H6 12.9 K= 5.45 13.9 20.3 H7 12.9 K= 5.45 13.3 19.9 H8 12.9 K= 5.45 13.2 19.8 1-19 12.9 K= 5.45 13.2 19.8 H10 12.9 K= 5.45 13.7 20.2 Nil 12.9 K= 5.45 22.8 26.0 H12 12.9 K= 5.45 22.7 26.0 1 12.2 - - - - 69.4 - - - 2 12.2 - - - - 69.4 - - - 3 12.2 - - - - 69.7 - - - 4 12.2 - - - - 70.1 - - - 5 12.2 - - - - 70.6 - - - 6 12.2 - - - - 71.2 - - - 7 12.2 - - - - 71.9 - - - 8 12.2 - - - - 74.6 - - - 9 12.2 - - - - 77.3 - - - 10 12.2 - - - - 77.0 - - - 11 12.2 - - - - 76.8 - - - 12 12.2 - - - - 76.7 - - - 13 12.9 - - - - 70.9 - - - 14 12.9 - - - - 71.3 - - - 15 12.9 - - - - 71.4 - - - 16 12.9 - - - - 70.1 - - - 17 12.9 - - - - 70.1 - - - 18 12.9 - - - - 70.2 - - - 19 12.2 - - - - 64.1 - - - 20 12.2 - - - - 64.0 - - - 21 12.2 - - - - 63.8 - - - 22 12.2 - - - - 63.7 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF .JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 23 12.2 - - - - 64.6 - - - 24 12.2 - - - - 65.6 - - - 25 12.2 - - - - 68.0 - - - 26 12.2 - - - - 68.4 - - - 27 12.2 - - - - 70.1 - - - 28 12.2 - - - - 70.5 - - - 29 12.2 - - - - 70.7 - - - 30 12.2 - - - - 70.7 - - - 31 12.2 - - - - 23.4 - - - 32 12.2 - - - - 24.1 - - - 33 12.2 - - - - 26.8 - - - 34 12.2 - - - - 30.4 - - - 35 12.2 - - - - 33.5 - - - 36 12.2 - - - - 38.2 - - - 37 12.2 - - - - 33.8 - - 38 12.2 - - - - 31.8 - - - 39 12.2 - - - - 31.5 - - - 40 12.2 - - - - 31.3 - - - 41 12.2 - - - - 31.1 - - - 42 12.2 - - - - 31.1 - - - 43 12.9 - - - - 29.7 - - - 44 12.9 - - - - 30.2 - - - 45 12.9 - - - - 30.2 - - - 46 12.9 - - - - 28.7 - - - 47 12.9 - - - - 28.7 - - - 48 12.9 - - - - 28.9 - - - 49 12.2 - - - - 21.8 - - - 50 12.2 - - - - 22.4 - - - 51 12.2 - - - - 24.6 - - - 52 12.2 - - - - 27.1 - - - 53 12.2 - - - - 28.2 - - - 54 12.2 - - - - 28.9 - - - 55 12.2 - - - - 29.5 - - - 56 12.2 - - - - 29.8 - - - 57 12.2 - - - - 30.0 - - - 58 12.2 - - - - 30.2 - - - 59 12.2 - - - - 30.2 - - - 60 2.0 - - - - 88.3 - - - TOR 12.2 - - - - 82.6 - - - BOR 0.0 HOSE STREAM 89.5 100.0 Ui 0.0 - - - - 90.1 - - - U2 0.0 - - - - 93.6 - - - U3 -6.0 SOURCE 96.4 350.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 25.2 1.508 PL 119.50 PF 5.3 1 12.2 0.0 69.4 0.0 4.5 120 FTG 3T3L PE 0.0 19 12.2 0.0 64.1 0.0 0.034 TL 155.50 PV Pipe: 2 25.8 1.508 PL 116.25 PF 5.4 2 12.2 0.0 69.4 0.0 4.6 120 FTG 4T PE 0.0 20 12.2 0.0 64.0 0.0 0.036 TL 152.25 PV Pipe: 3 26.9 1.508 PL 116.25 PF 5.9 3 12.2 0.0 69.7 0.0 4.8 120 FTG 4T PE 0.0 21 12.2 0.0 63.8 0.0 0.038 TL 152.25 PV Pipe: 4 26.4 1.508 PL 116.25 PF 5.4 4 12.2 0.0 70.1 0.0 4.7 120 FTG 3TL PE 0.0 23 12.2 0.0 64.6 0.0 0.037 TL 146.25 PV Pipe: 5 25.2 1.508 PL 116.25 PF 5.0 5 12.2 0.0 70.6 0.0 4.5 120 FTG 3TL PE 0.0 24 12.2 0.0 65.6 0.0 0.034 TL 146.25 PV Pipe: 6 0.7 1.508 PL 18.50 PF 0.0 6 12.2 0.0 71.2 0.0 0.1 120 FTG 2T PE -0.3 13 12.9 0.0 70.9 0.0 0.000 TL 36.50 PV Pipe: 7 10.5 1.508 PL 18.50 PP 0.3 7 12.2 0.0 71.9 0.0 1.9 120 FTG 3T PE -0.3 14 12.9 0.0 71.3 0.0 0.007 TL 45.50 PV Pipe: 8 35.3 1.508 PL 18.50 PF 2.9 8 12.2 0.0 74.6 0.0 6.3 120 FTG 3T PE -0.3 15 12.9 0.0 71.4 0.0 0.063 TL 45.50 PV Pipe: 9 25.5 1.508 PL 149.75 PF 6.5 10 12.2 0.0 77.0 0.0 4.6 120 FTG 4T PE 0.0 28 12.2 0.0 70.5 0.0 0.035 TL 185.75 PV Pipe: 10 24.6 1.508 PL 149.75 PP 6.1 11 12.2 0.0 76.8 0.0 4.4 120 FTG 4T PE 0.0 29 12.2 0.0 70.7 0.0 0.033 TL 185.75 PV Pipe: 11 24.4 1.508 PL 149.75 PP 5.9 12 12.2 0.0 76.7 0.0 4.4 120 FTG 4T PE 0.0 30 12.2 0.0 70.7 0.0 0.032 TL 185.75 PV Pipe: 12 22.7 1.508 PL 27.50 PP 0.8 13 12.9 0.0 70.9 0.0 4.1 120 FTG ---- PE 0.0 16 12.9 0.0 70.1 0.0 0.028 TL 27.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/21/2006 1 C:\DATA\CONPALFORUM1STF.SDF .JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 18.2 1.508 PL 81.25 PF 2.0 17 12.9 0.0 70.1 0.0 3.3 120 FTG 3T PE 0.3 26 12.2 0.0 68.4 0.0 0.019 TL 108.25 PV Pipe: 14 7.1 1.508 PL 103.75 PF 0.4 18 12.9 0.0 70.2 0.0 1.3 120 FTG 3T FE 0.3 27 12.2 0.0 70.1 0.0 0.003 TL 130.75 PV Pipe: 15 23.8 1.508 FL 30.75 PF 1.1 15 12.9 0.0 71.4 0.0 4.3 120 FTG 2L FE 0.0 18 12.9 0.0 70.2 0.0 0.031 TL 36.75 PV Pipe: 16 21.2 1.508 PL 81.25 PF 2.5 16 12.9 0.0 70.1 0.0 3.8 120 FTG 2T FE 0.3 25 12.2 0.0 68.0 0.0 0.025 TL 99.25 PV Pipe: 17 -21.9 1.508 PL 6.67 PF 0.4 13 12.9 0.0 70.9 0.0 3.9 120 FTG T PE 0.0 14 12.9 0.0 71.3 0.0 0.026 TL 15.67 PV Pipe: 18 -11.5 1.508 PL 7.29 PF 0.1 14 12.9 0.0 71.3 0.0 2.1 120 FTG ---- PE 0.0 15 12.9 0.0 71.4 0.0 0.008 TL 7.29 PV Pipe: 19 1.5 1.508 FL 6.67 PF 0.0 16 12.9 0.0 70.1 0.0 0.3 120 FTG T PE 0.0 17 12.9 0.0 70.1 0.0 0.000 TL 15.67 PV Pipe: 20 -16.7 1.508 FL 7.29 PF 0.1 17 12.9 0.0 70.1 0.0 3.0 120 FTG ---- FE 0.0 18 12.9 0.0 70.2 0.0 0.016 TL 7.29 PV Pipe: 21 51.4 1.508 PL 57.67 PF 9.6 31 12.2 0.0 23.4 0.0 9.2 120 FTG 2T FE -0.3 Hi 12.9 5.5 13.5 20.0 0.127 TL 75.67 PV Pipe: 22 31.4 1.508 FL 11.08 PF 0.6 Hi 12.9 5.5 13.5 20.0 5.6 120 FTG ---- PE 0.0 H2 12.9 5.5 12.9 19.6 0.051 TL 11.08 PV Pipe: 23 11.9 1.508 FL 11.08 PF 0.1 H2 12.9 5.5 12.9 19.6 2.1 120 FTG ---- PE 0.0 H3 12.9 5.5 12.8 19.5 0.008 TL 11.08 PV Pipe: 24 -7.6 1.508 FL 11.08 PF 0.0 H3 12.9 5.5 12.8 19.5 1.4 120 FTG ---- FE 0.0 H4 12.9 5.5 12.8 19.5 0.004 TL 11.08 FV Pipe: 25 -27.2 1.508 FL 11.08 PF 0.4 H4 12.9 5.5 12.8 19.5 4.9 120 FTG ---- FE 0.0 H5 12.9 5.5 13.3 19.9 0.039 TL 11.08 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 26 -47.0 1.508 PL 57.58 PF 8.2 H5 12.9 5.5 13.3 19.9 8.4 120 FTG 2T PE 0.3 49 12.2 0.0 21.8 0.0 0.108 TL 75.58 PV Pipe: 27 52.3 1.508 PL 57.67 PF 10.0 32 12.2 0.0 24.1 0.0 9.4 120 FTG 2T PE -0.3 H6 12.9 5.5 13.9 20.3 0.132 TL 75.67 PV Pipe: •28 32.0 1.508 PL 11.08 PF 0.6 H6 12.9 5.5 13.9 20.3 5.7 120 FTG ---- PE 0.0 H7 12.9 5.5 13.3 19.9 0.053 TL 11.08 PV Pipe: 29 12.1 1.508 PL 11.08 PF 0.1 H7 12.9 5.5 13.3 19.9 2.2 120 FTG ---- PE 0.0 H8 12.9 5.5 13.2 19.8 0.009 TL 11.08 PV Pipe: 30 -7.7 1.508 PL 11.08 PF 0.0 H8 12.9 5.5 13.2 19.8 1.4 120 FTG ---- PE 0.0 H9 12.9 5.5 13.2 19.8 0.004 TL 11.08 PV Pipe: 31 -27.5 1.508 PL .11.08 PF 0.4 H9 12.9 5.5 13.2 19.8 4.9 120 FTG ---- PE 0.0 H10 12.9 5.5 13.7 20.2 0.040 TL 11.08 PV Pipe: 32 -47.7 1.508 PL 57.58 PF 8.4 H10 12.9 5.5 13.7 20.2 8.6 120 FTG 2T PE 0.3 50 12.2 0.0 22.4 0.0 0.111 TL 75.58 PV Pipe: 33 35.8 1.508 PL 57.67 PF 3.8 33 12.2 0.0 26.8 0.0 6.4 120 FTG ---- PE -0.3 H11 12.9 5.5 22.8 26.0 0.065 TL 57.67 PV Pipe: 34 9.8 1.508 PL 11.08 PF 0.1 H11 12.9 5.5 22.8 26.0 1.8 120 FTG ---- PE 0.0 H12 12.9 5.5 22.7 26.0 0.006 TL 11.08 PV Pipe: 35 -16.2 1.508 PL 90.83 PF 1.6 H12 12.9 5.5 22.7 26.0 2.9 120 FTG 2T PE 0.3 51 12.2 0.0 24.6 0.0 0.015 TL 108.83 PV Pipe: 36 6.3 1.508 PL 102.08 PF 0.3 34 12.2 0.0 30.4 0.0 1.1 120 FTG 2T2L PE -0.3 43 12.9 0.0 29.7 0.0 0.003 TL 126.08 PV Pipe: 37 20.5 1.508 PL 102.08 PF 3.0 35 12.2 0.0 33.5 0.0 3.7 120 FTG 3T PE -0.3 44 12.9 0.0 30.2 0.0 0.023 TL 129.08 PV Pipe: 38 24.3 1.508 PL 86.42 PF 3.4 37 12.2 0.0 33.8 0.0 4.4 120 FTG 2TF PE -0.3 45 12.9 0.0 30.2 0.0 0.032 TL 105.42 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 39 15.9 1.508 PL 126.08 PF 2.3 38 12.2 0.0 31.8 0.0 2.8 120 FTG 4T PE 0.0 55 12.2 0.0 29.5 0.0 0.014 TL 162.08 PV Pipe: 40 13.3 1.508 PL 126.08 PF 1.7 39 12.2 0.0 31.5 0.0 2.4 120 FTG 4T PE 0.0 56 12.2 0.0 29.8 0.0 0.010 TL 162.08 PV Pipe: 41 11.2 1.508 PL 126.08 PF 1.2 40 12.2 0.0 31.3 0.0 2.0 120 FTG 4T PE 0.0 57 12.2 0.0 30.0 0.0 0.008 TL 162.08 PV Pipe: 42 10.0 1.508 PL 126.08 PF 1.0 41 12.2 0.0 31.1 0.0 1.8 120 FTG 4T PE 0.0 58 12.2 0.0 30.2 0.0 0.006 TL 162.08 PV Pipe: .43 9.6 1.508 PL 129.33 PF 0.9 42 12.2 0.0 31.1 0.0 1.7 120 FTG 3T3L PE 0.0 59 12.2 0.0 30.2 0.0 0.006 TL 165.33 PV Pipe: 44 27.6 1.508 PL 25.17 PF 1.0 43 12.9 0.0 29.7 0.0 5.0 120 FTG ---- PE 0.0 46 12.9 0.0 28.7 0.0 0.040 TL 25.17 PV Pipe: 45 26.5 1.508 PL 33.96 PF 1.9 46 12.9 0.0 28.7 0.0 4.8 120 FTG 2T PE 0.3 52 12.2 0.0 27.1 0.0 0.037 TL 51.96 PV Pipe: 46 15.3 1.508 PL 32.33 PF 0.8 47 12.9 0.0 28.7 0.0 2.7 120 FTG 3T PE 0.3 53 12.2 0.0 28.2 0.0 0.014 TL 59.33 PV Pipe: 47 23.4 1.508 PL 25.17 PF 1.3 45 12.9 0.0 30.2 0.0 4.2 120 FTG 2T PE 0.0 48 12.9 0.0 28.9 0.0 0.030 TL 43.17 PV Pipe: 48 9.3 1.508 PL 32.33 PF 0.3 48 12.9 0.0 28.9 0.0 1.7 120 FTG 2T PE 0.3 54 12.2 0.0 28.9 0.0 0.005 TL 50.33 PV Pipe: 49 -21.3 1.508 PL 8.92 PF 0.4 43 12.9 0.0 29.7 0.0 3.8 120 FTG T PE 0.0 44 12.9 0.0 30.2 0.0 0.025 TL 17.92 PV Pipe: 50 -0.9 1.508 PL 6.67 PF 0.0 44 12.9 0.0 30.2 0.0 0.2 120 FTG T PE 0.0 45 12.9 0.0 30.2 0.0 0.000 TL 15.67 PV Pipe: 51 1.2 1.508 PL 8.92 PF 0.0 46 12.9 0.0 28.7 0.0 0.2 120 FTG T PE 0.0 47 12.9 0.0 28.7 0.0 0.000 TL 17.92 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT. DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 52 -14.1 1.508 PL 6.67 PF 0.2 47 12.9 0.0 28.7 0.0 2.5 120 FTG T PE 0.0 48 12.9 0.0 28.9 0.0 0.012 TL 15.67 PV Pipe: 53 -47.0 1.748 PL 11.75 PF 0.6 49 12.2 0.0 21.8 0.0 6.3 120 FTG ---- PE 0.0 50 12.2 0.0 22.4 0.0 0.053 TL 11.75 PV Pipe: 54 -94.7 1.748 PL 11.75 PF 2.3 50 12.2 0.0 22.4 0.0 12.7 120 FTG ---- PE 0.0 51 12.2 0.0 24.6 0.0 0.192 TL 11.75 PV Pipe: 55 -110.9 1.748 PL 9.54 PF 2.5 51 12.2 0.0 24.6 0.0 14.8 120 FTG ---- PE 0.0 52 12.2 0.0 27.1 0.0 0.257 TL 9.54 PV Pipe: 56 -84.4 1.748 PL 7.29 PF 1.1 52 12.2 0.0 27.1 0.0 11.3 120 FTG ---- PE 0.0 53 12.2 0.0 28.2 0.0 0.155 TL 7.29 PV Pipe: 57 -69.1 1.748 PL 6.67 PF 0.7 53 12.2 0.0 28.2 0.0 9.2 120 FTG ---- PE 0.0 54 12.2 0.0 28.9 0.0 0.107 TL 6.67 PV Pipe: 58 -59.9 1.748 PL 6.54 PF 0.5 54 12.2 0.0 28.9 0.0 8.0 120 FTG ---- PE 0.0 55 12.2 0.0 29.5 0.0 0.082 TL 6.54 PV Pipe: 59 -44.0 1.748 PL 7.04 PF 0.3 55 12.2 0.0 29.5 0.0 5.9 120 FTG ---- PE 0.0 56 12.2 0.0 29.8 0.0 0.047 TL 7.04 PV Pipe: 60 -30.7 1.748 PL 9.42 9F 0.2 56 12.2 0.0 29.8 0.0 4.1 120 FTG ---- PE 0.0 57 12.2 0.0 30.0 0.0 0.024 TL 9.42 PV Pipe: 61 -19.5 1.748 PL 11.75 PF 0.1 57 12.2 0.0 30.0 0.0 2.6 120 FTG ---- PE 0.0 58 12.2 0.0 30.2 0.0 0.010 TL 11.75 PV Pipe: 62 -9.6 1.748 PL 11.75 PF 0.0 58 12.2 0.0 30.2 0.0 1.3 . 120 FTG ---- PE 0.0 59 12.2 0.0 30.2 0.0 0.003 TL 11.75 PV Pipe: 63 -51.4 1.748 PL 11.75 PF 0.7 31 12.2 0.0 23.4 0.0 6.9 120 FTG ---- PE 0.0 32 12.2 0.0 24.1 0.0 0.062 TL 11.75 PV Pipe: 64 -103.7 1.748 PL 11.75 PF 2.7 32 12.2 0.0 24.1 0.0 13.9 120 FTG ---- PE 0.0 33 12.2 0.0 26.8 0.0 0.227 TL 11.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 65 -139.5 1.748 PL 9.04 PF 3.6 33 12.2 0.0 26.8 0.0 18.6 120 FTG ---- PE 0.0 34 12.2 0.0 30.4 0.0 0.393 TL 9.04 PV Pipe: 66 -145.8 1.748 PL 7.29 PF 3.1 34 12.2 0.0 30.4 0.0 19.5 120 FTG ---- PE 0.0 35 12.2 0.0 33.5 0.0 0.427 TL 7.29 PV Pipe: 67 -166.2 1.748 PL 8.67 PF 4.7 35 12.2 0.0 33.5 0.0 22.2 120 FTG ---- PE 0.0 36 12.2 0.0 38.2 0.0 0.544 TL 8.67 PV Pipe: 68 84.2 1.748 PL 16.17 PF 4.4 36 12.2 0.0 38.2 0.0 11.3 120 FTG T PE 0.0 37 12.2 0.0 33.8 0.0 0.154 TL 28.17 PV Pipe: 69 59.9 1.748 PL 21.71 PF 2.0 37 12.2 0.0 33.8 0.0 8.0 120 FTG L PE 0.0 38, 12.2 0.0 31.8 0.0 0.082 TL 24.71 PV Pipe: 70 44.0 1.748 PL 7.04 PF 0.3 38 12.2 0.0 31.8 0.0 5.9 120 FTG ---- PE 0.0 39 12.2 0.0 31.5 0.0 0.047 TL 7.04 PV Pipe: 71 30.7 1.748 PL 9.42 PF 0.2 39 12.2 0.0 31.5 0.0 4.1 120 FTG ---- PE 0.0 40 12.2 0.0 31.3 0.0 0.024 TL 9.42 PV Pipe: 72 19.5 1.748 PL 11.75 PF 0.1 40 12.2 0.0 31.3 0.0 2.6 120 FTG ---- PE 0.0 41 12.2 0.0 31.1 0.0 0.010 TL 11.75 PV Pipe: 73 9.6 1.748 PL 8.50 PF 0.0 41 12.2 0.0 31.1 0.0 1.3 120 FTG ---- PE 0.0 42 12.2 0.0 31.1 0.0 0.003 TL 8.50 PV Pipe: 74 -250.4 2.223 PL 52.67 PF 25.5 36 12.2 0.0 38.2 0.0 20.7 120 FTG T2F PE 0.0 22 12.2 0.0 63.7 0.0 0.360 TL 70.67 PV Pipe: 75 25.2 2.223 PL 8.50 PF 0.0 19 12.2 0.0 64.1 0.0 2.1 120 FTG ---- PE 0.0 20 12.2 0.0 64.0 0.0 0.005 TL 8.50 PV Pipe: 76 51.0 2.223 PL 11.75 PF 02 20 12.2 0.0 64.0 0.0 4.2 120 FTG ---- PE 0.0 21 12.2 0.0 63.8 0.0 0.019 TL 11.75 PV Pipe: 77 77.9 2.223 PL 3.92 PF 0.2 21 12.2 0.0 63.8 0.0 6.4 120 FTG ---- PE 0.0 22 12.2 0.0 63.7 0.0 0.042 TL 3.92 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 3/21/2006 C:\DATA\CONPALFORUM15TF.SDF .JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. • END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 78 -172.5 2.223 PL 5.50 PP 1.0 22 12.2 0.0 63.7 0.0 14.3 120 FTG ---- PE 0.0 23 12.2 0.0 64.6 0.0 0.181 TL 5.50 PV Pipe: 79 -146.1 2.223 PL 7.04 PF 0.9 23 12.2 0.0 64.6 0.0 12.1 120 FTG ---- PE 0.0 24 12.2 0.0 65.6 0.0 0.133 TL 7.04 PV Pipe: 80 -120.9 2.223 PL 17.54 PF 2.4 24 12.2 0.0 65.6 0.0 10.0 120 FTG 2L PE 0.0 25 12.2 0.0 68.0 0.0 0.094 TL 25.54 PV Pipe: 81 -99.7 2.223 PL 6.67 PP, 0.4 25 12.2 0.0 68.0 0.0 8.2 120 FTG ---- PE 0.0 26 12.2 0.0 68.4 0.0 0.066 TL 6.67 PV Pipe: 82 -81.6 2.223 PL 29.79 PF 1.7 26 12.2 0.0 68.4 0.0 6.7 120 FTG 2L PE 0.0 27 12.2 0.0 70.1 0.0 0.045 TL 37.79 PV Pipe: 83 -74.5 2.223 PL 9.54 PF 0.4 27 12.2 0.0 70.1 0.0 6.2 120 FTG ---- PE 0.0 28 12.2 0.0 70.5 0.0 0.038 TL 9.54 PV Pipe: 84 -49.0 2.223 PL 11.75 PF 0.2 28 12.2 0.0 70.5 0.0 4.0 120 FTG ---- PE 0.0 29 12.2 0.0 70.7 0.0 0.018 TL 11.75 PV Pipe: 85 -24.4 2.223 PL 11.75 PF 0.1 29 12.2 0.0 70.7 0.0 2.0 120 FTG ---- PE 0.0 30 12.2 0.0 70.7 0.0 0.005 TL 11.75 PV Pipe: 86 -25.2 2.223 PL 11.75 PP 0.1 1 12.2 0.0 69.4 0.0 2.1 120 FTG ---- PE 0.0 2 12.2 0.0 69.4 0.0 0.005 TL 11.75 PV Pipe: 87 -51.0 2.223 PL 11.75 PF 0.2 2 12.2 0.0 69.4 0.0 4.2 120 FTG ---- PE 0.0 3 12.2 0.0 69.7 0.0 0.019 TL 11.75 PV Pipe: 88 -77.9 2.223 PL 9.42 PF 0.4 3 12.2 0.0 69.7 0.0 6.4 120 FTG ---- PE 0.0 4 12.2 0.0 70.1 0.0 0.042 TL 9.42 PV Pipe: 89 -104.3 2.223 PL 7.04 PP 0.5 4 12.2 0.0 70.1 0.0 8.6 120 FTG ---- PE 0.0 5 12.2 0.0 70.6 0.0 0.071 TL 7.04 PV Pipe: 90 -129.5 2.223 PL 6.04 PF 0.6 5 12.2 0.0 70.6 0.0 10.7 120 FTG ---- PE 0.0 6 12.2 0.0 71.2 0.0 0.106 TL 6.04 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 91 -130.2 2.223 PL 6.67 PF 0.7 6 12.2 0.0 71.2 0.0 10.8 120 FTG ---- PE 0.0 7 12.2 0.0 71.9 0.0 0.107 TL 6.67 PV Pipe: 92 -140.7 2.223 PL 7.29 PF 2.6 7 12.2 0.0 71.9 0.0 11.6 120 FTG T PE 0.0 8 12.2 0.0 74.6 0.0 0.124 TL 21.29 PV Pipe: 93 -175.9 2.223 PL 0.62 PF 2.7 8 12.2 0.0 74.6 0.0. 14.5 120 FTG T PE 0.0 9 12.2 0.0 77.3 0.0 0.187 TL 14.62 PV Pipe: 94 74.5 2.223 PL 8.92 PF 0.3 9 12.2 0.0 77.3 0.0 6.2 120 FTG ---- PE 0.0 10 12.2 0.0 77.0 0.0 0.038 TL 8.92 PV Pipe: 95 49.0 2.223 PL 11.75 PF 0.2 10 12.2 0.0 77.0 0.0 4.0 120 FTG ---- PE 0.0 11 12.2 0.0 76.8 0.0 0.018 TL 11.75 PV Pipe: 96 24.4 2.223 PL 11.75 PF 0.1 11 12.2 0.0 76.8 0.0 2.0 120 FTG ---- PE 0.0 12 12.2 0.0 76.7 0.0 0.005 TL 11.75 PV Pipe: 97 -250.4 2.723 PL 20.25 PF 5.3 9 12.2 0.0 77.3 0.0 13.8 120 FTG T PE 0.0 TOR 12.2 0.0 82.6 0.0 0.134 TL 39.25 PV Pipe: 98 -250.4 2.723 PL 10.17 PF 1.4 TOR 12.2 0.0 82.6 0.0 13.8 120 FTG ---- PE 4.4 60 2.0 0.0 88.3 0.0 0.134 TL 10.17 PV Pipe: 99 -250.4 4.328 PL 5.00 PF 0.3 60 2.0 0.0 88.3 0.0 5.5 120 FTG 2L PE 0.9 BOR 0.0 H.S. 89.5 100.0 0.014 TL 23.00 PV Pipe: 100 -350.4 6.134 PL 151.00 PF 0.6 BOR 0.0 H.S. 89.5 100.0 3.8 150 FTG 5LG PE 0.0 Ui 0.0 0.0 90.1 0.0 0.003 TL 199.00 PV Pipe: 101 FIXED PRESSURE LOSS DEVICE U2 0.0 0.0 93.6 0.0 3.5 psi, 350.4 gpm Ui 0.0 0.0 90.1 0.0 Pipe: 102 -350.4 6.134 PL 10.00 PF 0.2 U2 0.0 0.0 93.6 0.0 3.8 150 FTG T2LG PE 2.6 U3 -6.0 SRCE 96.4 (N/A) 0.003 TL 61.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 NOTES: (1) Calculations were performed by the HASS 7.7 computer program under license no. 38010408 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.064 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 22.2 ft/sec at pipe 67. (4) a. System remote area HAS been proven or 'peaked' Minimum pressure at any sprinkler: 12.802 psi Minimum pressure with remote area shifted one sprinkler space toward left cross main: 12.825 psi Minimum pressure with remote area shifted one sprinkler space toward right cross main: 12.805 psi (5) PIPE FITTINGS TABLE Pipe Table Name: LINDLEY.PIP PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N F Eli Tee LngEll ChkVlv BfyVl.v GatVlv NPTee 45 6.134 21.00 30.00 9.00 32.00 15.00 3.00 30.00 7.00 PAGE: J MATERIAL: LINDLE HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll --------------------------------------------------------ChkVlv BfyVlv GatVlv AimChk DPVlv NPTee 45 1.508 5.00 9.00 3.00 12.00 12.00 2.00 20.00 17.00 7.00 1.00 1.748 6.00 12.00 3.00 14.00 11.00 2.00 18.00 15.00 10.00 2.00 2.223 7.00 14.00 4.00 15.00 10.00 1.00 17.00 14.00 12.00 2.00 2.723 10.00 19.00 6.00 22.00 16.00 2.00 22.00 16.00 17.00 3 .00 4.328 14.00 28.00 9.00 31.00 22.00 4.00 35.00 14.00 26.00 4.00 120. 0 20.0 0.0 -14.7 WATER SUPPLY ANALYSIS Static: 109.80 psi Resid: 104.40 psi Flow: 1500.0 gpm LEGEND Available pressure 109.09 psi @ 500.4 gpm Required pressure 96.44 psi @ 500.4 gpm Source Supply Curve System Demand Curve 100. 0 G A U G Ts P R E S S 60.0 U R E 40.0 P S i 1 UU bUU duu 1000 1200 1400 1600 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 WATER SUPPLY CURVE 120+ 110*\\\\0\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\\ * <-104.4 psi 0 1500 gpm Flow Test Point 100+ I X 90+ P 80+ R I E I S I 5 70+ U I R I E I 60+ ( I P S I 50+ ) I 40+ 30+ 20+ LEGEND I 'I I X = Required Water Supply I 96.44 psi 0 500.4 gpm 10+ 0 = Available Water Supply 109.09 psi 0 500.4 gpm U 0++-+---+----+-----+------+--------+--------+---------+-----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14 DATE: 3/21/2006 C:\DATA\CONPALFORUM1STF.SDF .JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 1ST FL .15 FOR 1500 SQ FT GROUP 1 -Utility Report: Equivalent K-Factor Calculator Node Sprinkler Pres. Dia. Pipe Ftgs. Total H-W Equivalent Name K-Factor (psi) (in) Len. (ft) Len. (ft) coef. K-factor ANY 5.60 7.00 1.080 ----------------------------------------------------------------------- 0.33 T 5.33 120.00 5.47 Equivalent K-Factor Calculator Node Sprinkler Pres. Dia. Pipe Ftgs. Total H-W Equivalent Name K-Factor (psi) (in) Len. (ft) Len. (ft) coef. K-factor ANY 5.60 7.00 1.049 33 120.00 b ëiiedule10/Schedule-40 0 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule- IO/Schedule-40 sprinkler pipe you get UL listed and FM approved product. Although these products do not require separate approvals, Schedule-i WSchedule-40 gives you the extra quality assurance you demand. Our Sch-lO (1¼"- 8") pipe and Sch-40 (1"- 2W) pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule- lO/Schedule-40 product J, can be "hot-dip" galvanized to meet FM requirements for dry / I systems in accordance with the zinc coating specifications of ASTM A-123. Superior Coating I Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-1O/Schedule-40 pipe are in compliance with the following: ASTMA-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test ____ Inal Wt/Ft Wt/Ft Pcf WtjUlt WtjUft WtjUft NIPS I.D. H2O Riled Uft 21' 24' 25' .x 1." 1.049 1.680 2.05 70 2470 2822 2940 *2 26.6 2.5 3.05 70 1120 1280 1334 1W 1.380 2.270 2.93 51 2431. 2778 2894 * 32 35.1. 4.36 4.36 51. 1103 1.260 1313 1½" 1.610 2.720 3.61 44 2513 2872 2992 *40 40.9 4.0 5.37 44 1140 1303 1357 *2" 2.067 3.650 5.13 30 2300 2628 2738 *50 52.5 5.4 7.63 30 1043 1192 1242 2½" 2.469 5.790 7.86 1.9 2310 2640 2750 *65 62.7 8.6 11.73 19 1048 1197 1247 Product Nominal W'Ft Wt/Ft PcI WtjlJft Wt/Uft Wt/Uft NPS I.D. II20FiiI.d Uft 21' 24' 25' 1.097 1.400 1.81 91 2675 3053 35 *25 27.9 2.1.. 2.70 .. 91 1213 1385 1445 1.44" 1.442 1.810 2.52 61 2319 2664 2760 * 32 36.6 2.7 3.75 61 1052 1208 1252 * 11h" 1.682 2.080 3.04 . 61 2664 3045 3172 * 40 42.7 3.1. 4.52 61 1208 1381 1439 2.157 2.640 4.22 37 2051 2344 2442 * 50 54.8 3.9 6.28 37 930 1063 1108 ,2%' 2.635 3.530 5.89 30 2224 2542 2648 *65 66.9 5.3 8.77 30 1009 1153 1201 3.260 4.330 7.94 19 1728 1975 2057 * 80 82.8 6.4 11.82 19 784 896 933 * 47 4.260 5.610 11.78 19 2238 2558 2665 *90 108.2 8.3 17.53 19 1015 1160 1209 5.295 7.77 17.33 10 1632 1865 1943 *125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1951 2230 2322 * 150 161.5 13.8 34.27 10 885 1012 1053 8" 8.249 16.490 40.15 7 2424 2770 2885 * 200 209.5 24.5 59.75 7 1100 1256 1309 $ dlied TUBE a CONDUIT .rnaMrm.siL was 16100 S. Lathrop 11350 Norcom Rd. 2525 N. 27th Ave. Cvstcvn.rS.n'c#: Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 1-800.882-5543 - Fax 708-339.1806 S4-17 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) U3 109.8 104.4 1500.0 109.1 490.1 4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 490.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 150.0 GPM OTHER HOSE STREAM ALLOWANCES 100.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 240.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) Hi 28.3 K= 5.45 12.4 19.2 H2 28.3 K= 5.45 12.0 18.9 H3 28.3 K= 5.45 11.9 18.8 H4 28.3 K= 5.45 11.9 18.8 H5 28.3 K= 5.45 12.4 19.2 H6 28.3 K= 5.45 12.9 19.5 H7 28.3 K= 5.45 12.4 19.2 H8 28.3 K= 5.45 12.3 19.1 H9 28.3 K= 5.45 12.3 19.1 H10 28.3 K= 5.45 12.8 19.5 Hil 28.3 K= 5.45 20.1 24.4 H12 28.3 K= 5.45 20.0 24.4 1 28.3 - - - - 68.3 - - - 2 28.3 - - - - 68.4 - - - 3 28.3 - - - - 68.5 - - - 4 28.3 - - - - 68.8 - - - 5 28.3 - - - - 68.3 - - - 6 28.3 - - - - 66.8 - - - 7 28.3 - - - - 65.7 - - - 8 28.3 - - - - 65.1 - - - 9 28.3 - - - - 64.8 - - - 10 28.3 - - - - 64.8 - - - 11 28.3 - - - - 66.8 - - - 12 28.3 - - - - 66.6 - - - 13 28.3 - - - - 63.5 - - - 14 28.3 - - - - 63.4 - - - 15 28.3 - - - - 63.3 - - - 16 28.3 - - - - 62.9 - - - 17 28.3 - - - - 59.9 - - - 18 28.3 - - - - 58.8 - - - 19 28.3 - - - - 57.8 - - - 20 28.3 - - - - 58.1 - - - 21 28.3 - - - - 58.4 - - - 22 28.3 - - - - 58.4 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 23 28.3 - - - - 30.0 - - - 24 28.3 - - - - 30.0 - - - 25 28.3 - - - - 30.2 - - - 26 28.3 - - - - 30.8 - - - 27 28.3 - - - - 35.2 - - - 28 28.3 - - - - 33.2 - - - 29 28.3 - - - - 28.1 - - - 30 28.3 - - - - 24.1 - - - 31 28.3 - - - - 21.7 - - - 32 28.3 - - - - 21.1 - - 33 28.3 - - - - 25.6 - - - 34 28.3 - - - - 25.4 - - - 35 28.3 - - - - 28.4 - - - 36 28.3 - - - - 28.4 - - - 37 28.3 - - - - 28.1 - - - 38 28.3 - - - - 27.6 - - - 39 28.3 - - - - 26.5 - - - 40 28.3 - - - - 24.4 - - - 41 28.3 - - - - 21.4 - - - 42 28.3 - - - - 19.2 - - - 43 28.3 - - - - 18.6 - - - 60 2.0 - - - - 88.5 - - - TOR-ROOF 28.3 - - - - 71.0 - - - TOR-1STF 12.2 - - - - 82.8 - - - BOR 0.0 HOSE STREAM 89.7 100.0 Ui 0.0 - - - - 90.3 - - - U2 0.0 - - - - 93.8 - - - U3 -6.0 SOURCE 96.6 340.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 22.4 1.508 PL 159.33 PF 4.8 1 28.3 0.0 68.3 0.0 4.0 120 FTG 2T PE 0.0 13 28.3 0.0 63.5 0.0 0.027 TL 177.33 PV Pipe: 2 22.6 1.508 PL 159.33 PF 4.9 2 28.3 0.0 68.4 0.0 4.1 120 FTG 2T PE 0.0 14 28.3 0.0 63.4 0.0 0.028 TL 177.33 PV Pipe: 3 23.5 1.508 PL 159.33 PF 5.3 3 28.3 0.0 68.5 0.0 4.2 120 FTG 2T PE 0.0 15 28.3 0.0 63.3 0.0 0.030 TL 177.33 PV Pipe: 4 23.6 1.508 PL 31.33 PF 1.5 5 28.3 0.0 68.3 0.0 4.2 120 FTG 2T PE 0.0 11 28.3 0.0 66.8 0.0 0.030 TL 49.33 PV Pipe: 5 30.1 1.508 PL 126.83 PF 6.8 6 28.3 0.0 66.8 0.0 5.4 120 FTG 2T PE 0.0 17 28.3 0.0 59.9 0.0 0.047 TL 144.83 PV Pipe: 6 30.2 1.508 PL 126.83 PF 6.9 7 28.3 0.0 65.7 0.0 5.4 120 FTG 2T PE 0.0 18 28.3 0.0 58.8 0.0 0.048 TL 144.83 PV Pipe: 7 30.6 1.508 PL 126.83 PF 7.0 8 28.3 0.0 65.1 0.0 5.5 120 FTG 2T PE 0.0 20 28.3 0.0 58.1 0.0 0.049 TL 144.83 PV Pipe: 8 29.2 1.508 PL 126.83 PF 6.5 9 28.3 0.0 64.8 0.0 5.3 120 FTG 2T PE 0.0 21 28.3 0.0 58.4 0.0 0.045 TL 144.83 PV Pipe: 9 28.0 1.508 PL 130.08 PF 6.4 10 28.3 0.0 64.8 0.0 5.0 120 FTG 2T2L PE 0.0 22 28.3 0.0 58.4 0.0 0.041 TL 154.08 PV Pipe: 10 11.9 1.508 PL 28.33 PF 0.3 11 28.3 0.0 66.8 0.0 2.1 120 FTG 2L PE 0.0 12 28.3 0.0 66.6 0.0 0.009 TL 34.33 PV Pipe: 11 23.6 1.508 PL 103.83 PF 3.7 12 28.3 0.0 66.6 0.0 4.2 120 FTG 2T PE 0.0 16 28.3 0.0 62.9 0.0 0.030 TL 121.83 PV Pipe: 12 11.7 1.508 PL 29.33 PF 0.3 11 28.3 0.0 66.8 0.0 2.1 120 FTG 2L PE 0.0 12 28.3 0.0 66.6 0.0 0.008 TL 35.33 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF -JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 13.4 1,508 PL 122.83 PF 1.5 23 28.3 0.0 30.0 0.0 2.4 120 FTG 2T2L PE 0.0 35 28.3 0.0 28.4 0.0 0.011 TL 146.83 PV Pipe: 14 14.3 1.508 PL 119.58 PF 1.6 24 28.3 0.0 30.0 0.0 2.6 120 FTG 2T PE 0.0 36 28.3 0.0 28.4 0.0 0.012 TL 137.58 PV Pipe: 15 16.4 1.508 PL 119.58 PF 2.1 25 28.3 0.0 30.2 0.0 2.9 120 FTG 2T PE 0.0 37 2-8.3 0.0 28.1 0.0 0.015 TL 137.58 PV Pipe: 16 20.5 1.508 PL 119.58 PF 3.2 26 28.3 0.0 30.8 0.0 3.7 120 FTG 2T PE 0.0 38 28.3 0.0 27.6 0.0 0.023 TL 137.58 PV Pipe: 17 26.8 1.508 PL 159.33 PF 6.7 28 28.3 0.0 33.2 0.0 4.8 120 FTG 2T PE 0.0 39 28.3 0.0 26.5 0.0 0.038 TL 177.33 PV Pipe: 18 19.1 1.508 PL 103.50 PF 2.5 29 28.3 0.0 28.1 0.0 3.4 120 FTG 2T PE 0.0 33 28.3 0.0 25.6 0.0 0.020 TL 121.50 PV Pipe: 19 9.4 1.508 PL 30.50 PF 0.2 33 28.3 0.0 25.6 0.0 1.7 120 FTG 2L PE 0.0 34 28.3 0.0 25.4 0.0 0.006 TL 36.50 PV Pipe: 20 9.7 1.508 PL 28.50 PF 0.2 33 28.3 0.0 25.6 0.0 1.7 120 FTG 2L PE 0.0 34 28.3 0.0 25.4 0.0 0.006 TL 34.50 PV Pipe: 21 19.1 1.508 PL 31.33 PF 1.0 34 28.3 0.0 25.4 0.0 3.4 120 FTG 2T PE 0.0 40 28.3 0.0 24.4 0.0 0.020 TL 49.33 PV Pipe: 22 32.1 1.508 PL 66.58 PF 4.0 30 28.3 0.0 24.1 0.0 5.8 120 FTG T PE 0.0 Hil 28.3 5.5 20.1 24.4 0.053 TL 75.58 PV Pipe: 23 7.7 1.508 PL 10.67 PF 0.1 Hil 28.3 5.5 20.1 24.4 1.4 120 FTG T PE 0.0 H12 28.3 5.5 20.0 24.4 0.004 TL 19.67 PV Pipe: 24 -16.7 1.508 PL 82.42 PF 1.4 H12 28.3 5.5 20.0 24.4 3.0 120 FTG T PE 0.0 41 28.3 0.0 21.4 0.0 0.016 TL 91.42 PV Pipe: 25 49.2 1.508 PL 66.58 PF 8.9 31 28.3 0.0 21.7 0.0 8.8 120 FTG T PE 0.0 H6 28.3 5.5 12.9 19.5 0.117 TL 75.58 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(PPS) HW(C) (PT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 26 29.6 1.508 PL 10.67 PP 0.5 H6 28.3 5.5 12.9 19.5 5.3 120 FTG ---- PE 0.0 H7 28.3 5.5 12.4 19.2 0.046 TL 10.67 PV Pipe: 27 10.5 1.508 PL 10.67 PF 0.1 H7 28.3 5.5 12.4 19.2 1.9 120 FTG ---- PE 0.0 H8 28.3 5.5 12.3 19.1 0.007 TL 10.67 PV Pipe: 28 -8.7 1.508 PL 10.67 PF 0.1 H8 28.3 5.5 12.3 19.1 1.6 120 FTG ---- PE 0.0 H9 28.3 5.5 12.3 19.1 0.005 TL 10.67 PV Pipe: 29 -27.8 1.508 PL 10.67 PF 0.4 H9 28.3 5.5 12.3 19.1 5.0 120 FTG ---- PE 0.0 H10 28.3 5.5 12.8 19.5 0.041 TL 10.67 PV Pipe: 30 -47.3 1.508 PL 50.08 PP 6.4 H10 28.3 5.5 12.8 19.5 8.5 120 FTG T PE 0.0 42 28.3 0.0 19.2 0.0 0.109 TL 59.08 PV Pipe: 31 48.4 1.508 PL 66.58 PF 8.6 32 28.3 0.0 21.1 0.0 8.7 120 FTG T PE 0.0 Hi 28.3 5.5. 12.4 19.2 0.114 TL 75.58 PV Pipe: 32 29.2 1.508 PL 10.67 PF 0.5 Hi 28.3 5.5 12.4 19.2 5.2 120 FTG ---- PE 0.0 H2 28.3 5.5 12.0 18.9 0.045 TL 10.67 PV Pipe: 33 10.3 1.508 PL 10.67 PF 0.1 H2 28.3 5.5 12.0 18.9 1.9 120 FTG ---- PE 0.0 H3 28.3 5.5 11.9 18.8 0.007 TL 10.67 PV Pipe: 34 -8.5 1.508 PL 10.67 PP 0.0 H3 28.3 5.5 11.9 18.8 1.5 120 FTG ---- PE 0.0 H4 28.3 5.5 11.9 18.8 0.005 TL 10.67 PV Pipe: 35 -27.3 1.508 PL 10.67 PF 0.4 H4 28.3 5.5 11.9 18.8 4.9 120 FTG ---- PE 0.0 H5 28.3 5.5 12.4 19.2 0.040 TL 10.67 PV Pipe: 36 -46.5 1.508 PL 50.08 PP 6.2 H5 28.3 5.5 12.4 19.2 8.3 120 FTG T PE 0.0 43 28.3 0.0 18.6 0.0 0.106 TL 59.08 PV Pipe: 37 13.4 1.748 PL 11.75 PP 0.1 35 28.3 0.0 28.4 0.10 1.8 120 FTG ---- PE 0.0 36 28.3 0.0 28.4 0.0 0.005 TL 11.75 PV Pipe: 38 27.7 1.748 PL 11.75 PP 0.2 36 28.3 0.0 28.4 0.0 3.7 120 FTG ---- PE 0.0 37 28.3 0.0 28.1 0.0 0.020 TL 11.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOE TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 39 44.0 1.748 PL 11.67 PF 0.5 37 28.3 0.0 28.1 0.0 5.9 120 FTG ---- PE 0.0 38 28.3 0.0 27.6 0.0 0.047 TL 11.67 PV Pipe: 40 64.5 1.748 PL 11.58 PF 1.1 38 28.3 0.0 27.6 0.0 8.6 120 FTG ---- PE 0.0 39 28.3 0.0 26.5 0.0 0.095 TL 11.58 PV Pipe: 41 91.3 1.748 PL 11.58 PE 2.1 39 28.3 0.0 26.5 0.0 12.2 120 FTG ---- PE 0.0 40 28.3 0.0 24.4 0.0 0.180 TL 11.58 PV Pipe: 42 110.4 1.748 PL 11.67 PF 3.0 40 28.3 0.0 24.4 0.0 14.8 120 FTG ---- PE 0.0 41 28.3 0.0 21.4 0.0 0.255 TL 11.67 PV Pipe: 43 93.8 1.748 PL 11.75 PF 2.2 41 28.3 0.0 21.4 0.0 12.5 120 FTG ---- PE 0.0 42 28.3 0.0 19.2 0.0 0.189 TL 11.75 PV Pipe: 44 46.5 1.748 PL 11.75 PF 0.6 42 28.3 0.0 19.2 0.0 6.2 120 FTG ---- PE 0.0 43 28.3 0.0 18.6 0.0 0.052 TL 11.75 PV Pipe: 45 -13.4 1.748 PL 8.00 PF 0.0 23 28.3 0.0 30.0 0.0 1.8 120 FTG ---- PE 0.0 24 28.3 0.0 30.0 0.0 0.005 TL 8.00 PV Pipe: 46 -27.7 1.748 PL 11.75 PF 0.2 24 28.3 0.0 30.0 0.0 3.7 120 FTG ---- PE 0.0 25 28.3 0.0 30.2 0.0 0.020 TL 11.75 PV Pipe: 47 -44.0 1.748 PL 11.67 PF 0.5 25 28.3 0.0 30.2 0.0 5.9 120 FTG ---- PE 0.0 26 28.3 0.0 30.8 0.0 0.047 TL 11.67 PV Pipe: 48 -64.5 1.748 PL 47.17 PF 4.5 26 28.3 0.0 30.8 0.0 8.6 120 FTG ---- PE 0.0 27 28.3 0.0 35.2 0.0 0.095 TL 47.17 PV Pipe: 49 175.6 1.748 PL 3.33 PF 2.0 27 28.3 0.0 35.2 0.0 23.5 120 FTG ---- PE 0.0 28 28.3 0.0 33.2 0.0 0.602 TL 3.33 PV Pipe: 50 148.8 1.748 PL 11.58 PF 5.1 28 28.3 0.0 33.2 0.0 19.9 120 FTG ---- PE 0.0 29 28.3 0.0 28.1 0.0 0.443 TL 11.58 PV Pipe: 51 129.7 1.748 PL 11.67 PF 4.0 29 28.3 0.0 28.1 0.0 17.3 120 FTG ---- PE 0.0 30 28.3 0.0 24.1 0.0 0.344 TL 11.67 PV • SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 52 97.6 1.748 PL 11.75 Pr 2.4 30 28.3 0.0 24.1 0.0 13.0 120 FTG ---- PE 0.0 31 28.3 0.0 21.7 0.0 0.203 TL 11.75 PV Pipe: 53 48.4 1.748 PL 11.75 PF 0.7 31 28.3 0.0 21.7 0.0 6.5 120 FTG ---- PE 0.0 32 28.3 0.0 21.1 0.0 0.056 TL 11.75 PV Pipe: 54 -240.1 2.223 PL 49.75 PF 22.6 27 28.3 0.0 35.2 0.0 19.8 120 FTG T2F PE 0.0 19 28.3 0.0 57.8 0.0 0.333 TL 67.75 PV Pipe: 55 22.4 2.223 PL 11.75 PF 0.0 13 28.3 0.0 63.5 0.0 1.8 120 FTG ---- PE 0.0 14 28.3 0.0 63.4 0.0 0.004 TL 11.75 PV Pipe: 56 44.9 2.223 PL 11.75 PF 0.2 14 28.3 0.0 63.4 0.0 3.7 120 FTG ---- PE 0.0 15 28.3 0.0 63.3 0.0 0.015 TL 11.75 PV Pipe: 57 68.4 2.223 PL 11.67 Pr 0.4 15 28.3 0.0 63.3 0.0 5.7 120 FTG ---- PE 0.0 16 28.3 0.0 62.9 0.0 0.033 TL 11.67 PV Pipe: 58 92.0 2.223 PL 44.25 Pr 3.0 16 28.3 0.0 62.9 0.0 7.6 120 FTG 2L PE 0.0 17 28.3 0.0 59.9 0.0 0.057 TL 52.25 PV Pipe: 59 122.1 2.223 PL 11.58 Pr 1.1 17 28.3 0.0 59.9 0.0 10.1 120 FTG ---- PE 0.0 18 28.3 0.0 58.8 0.0 0.095 TL 11.58 PV Pipe: 60 152.3 2.223 PL 6.92 Pr 1.0 18 28.3 0.0 58.8 0.0 12.6 120 FTG ---- PE 0.0 19 28.3 0.0 57.8 0.0 0.144 TL 6.92 PV Pipe: 61 -87.8 2.223 PL 4.92 PF 0.3 19 28.3 0.0 57.8 0.0 7.3 120 FTG ---- PE 0.0 20 28.3 0.0 58.1 0.0 0.052 TL 4.92 PV Pipe: 62 -57.2 2.223 PL 11.75 Pr 0.3 20 28.3 0.0 58.1 0.0 4.7 120 FTG ---- PE 0.0 21 28.3 0.0 58.4 0.0 0.023 TL 11.75 PV Pipe: 63 -28.0 2.223 PL 8.00 Pr 0.0 21 28.3 0.0 58.4 0.0 2.3 120 FTG ---- PE 0.0 22 28.3 0.0 58.4 0.0 0.006 TL 8.00 PV Pipe: 64 -22.4 2.223 PL 11.75 PF 0.0 1 28.3 0.0 68.3 0.0 1.8 120 FTG ---- PE 0.0 2 28.3 0.0 68.4 0.0 0.004 TL 11.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 65 -44.9 2.223 PL 11.75 PF 0.2 2 28.3 0.0 68.4 0.0 3.7 120 FTG ---- PE 0.0 3 28.3 0.0 68.5 0.0 0.015 TL 11.75 PV Pipe: 66 -68.4 2.223 PL 8.92 PF 0.3 3 28.3 0.0 68.5 0.0 5.7 120 FTG ---- PE 0.0 4 28.3 0.0 68.8 0.0 0.033 TL 8.92 PV Pipe: 67 171.7 2.223 PL 2.75 PF 0.5 4 28.3 0.0 68.8 0.0 14.2 120 FTG ---- PE 0.0 5 28.3 0.0 68.3 0.0 0.179 TL 2.75 PV Pipe: 68 148.1 2.223 PL 11.58 PF 1.6 5 28.3 0.0 68.3 0.0 12.2 120 FTG ---- PE 0.0 6 28.3 0.0 66.8 0.0 0.136 TL 11.58 PV Pipe: 69 118.0 2.223 PL 11.58 PF 1.0 6 28.3 0.0 66.8 0.0 9.8 120 FTG ---- PE 0.0 7 28.3 0.0 65.7 0.0 0.090 TL 11.58 PV Pipe: 70 87.8 2.223 PL 11.67 PF 0.6 7 28.3 0.0 65.7 0.0 7.3 120 FTG ---- PE 0.0 8 28.3 0.0 65.1 0.0 0.052 TL 11.67 PV Pipe: 71 57.2 2.223 PL 11.75 PF 0.3 8 28.3 0.0 65.1 0.0 4.7 120 FTG ---- PE 0.0 9 28.3 0.0 64.8 0.0 0.023 TL 11.75 PV Pipe: 72 28.0 2.223 PL 11.75 PF 0.1 9 28.3 0.0 64.8 0.0 2.3 120 FTG ---- PE 0.0 10 28.3 0.0 64.8 0.0 0.006 TL 11.75 PV Pipe: 73 -240.1 2.723 PL 11.08 PF 2.1 4 28.3 0.0 68.8 0.0 13.2 120 FTG L PE 0.0 TOR-ROOF 28.3 0.0 71.0 0.0 0.124 TL 17.08 PV Pipe: 74 -240.1 2.723 PL 14.67 PF 4.9 TOR-ROOF 28.3 0.0 71.0 0.0 13.2 120 FTG TL PE 7.0 TOR-1STF 12.2 0.0 82.8 0.0 0.124 TL 39.67 PV Pipe: 75 -240.1 2.723 PL 10.17 PF 1.3 TOR-1STF 12.2 0.0 82.8 0.0 13.2 120 FTG ---- PE 4.4 60 2.0 0.0 88.5 0.0 0.124 TL 10.17 PV Pipe: 76 -240.1 4.328 PL 5.00 PF 0.3 60 2.0 0.0 88.5 0.0 5.2 120 FTG 2L PE 0.9 BOR 0.0 H.S. 89.7 100.0 0.013 TL 23.00 PV Pipe: 77 -340.1 6.134 PL 151.00 PF 0.6 BOR 0.0 H.S. 89.7 100.0 3.7 150 FTG 5LG PE 0.0 Ui 0.0 0.0 90.3 0.0 0.003 TL 199.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 78 FIXED PRESSURE LOSS DEVICE U2 0.0 0.0 93.8 0.0 3.5 psi, 340.1 gpm Ui 0.0 0.0 90.3 0.0 Pipe: 79 -340.1 6.134 PL 10.00 PF 0.2 U2 0.0 0.0 93.8 0.0 3.7 150 FTG T2LG PE 2.6 U3 -6.0 SRCE 96.6 (N/A) 0.003 TL 61.00 PV NOTES: (1) Calculations were performed by the HASS 7.7 computer program under license no. 38010408 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.085 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 23.5 ft/sec at pipe 49. (4) a. System remote area HAS been proven or 'peaked' Minimum pressure at any sprinkler: 11.899 psi Minimum pressure with remote area shifted one sprinkler space toward left cross main: 11.905 psi Minimum pressure with remote area shifted one sprinkler space toward right cross main: 11.918 psi (5) PIPE FITTINGS TABLE Pipe Table Name: LINDLEY.PIP PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N F Ell Tee LngEll ChkVlv BfyVlv GatVlv NPTee 45 6.134 21.00 30.00 9.00 32.00 15.00 3.00 30.00 7.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF .JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 PAGE: J MATERIAL: LINDLE HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEii --------------------------------------------------------ChkVlv BfyVlv GatVlv AlmChk DPViv NPTee 45 1.508 5.00 9.00 3.00 12.00 12.00 2.00 20.00 17.00 7.00 1.00 1.748 6.00 12.00 3.00 14.00 11.00 2.00 18.00 15.00 10.00 2.00 2.223 7.00 14.00 4.00 15.00 10.00 1.00 17.00 14.00 12.00 2.00 2.723 10.00 19.00 6.00 22.00 16.00 2.00 22.00 16.00 17.00 3.00 4.328 14.00 28.00 9.00 31.00 22.00 4.00 35.00 14.00 26.00 4.00 120.0 100. 0 G A U G E 80.0 P R E S S 60.0 U R E 40.0 p S i 20.0 0.0 WATER SUPPLY ANALYSIS Static: 109.80 psi Resid: 104.40 psi Flow: 1500.0 gpm LEGEND Available pressure 109.12 psi @ 490.1 gpm Required pressure 96.57 psi @ 490.1 gpm_ Source Supply Curve System Demand Curve 400 600 800 1000 1200 1400 1600 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF .JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 WATER SUPPLY CURVE 120+ 110*\\\\0\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\\ I * <-104.4 psi @ 1500 gpm I Flow Test Point 100+ I X 90+ P 80+ R I E I S I S 70+ U I R I E I 60+ P I S I I 50+ 40+ 30+ 20+ LEGEND I I X = Required Water Supply U I 96.57 psi @ 490.1 gpm 10+ I 0 = Available Water Supply I 109.12 psi @ 490.1 gpm 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 3/17/2006 C:\DATA\CONPALFORM2NDFX.SDF JOB TITLE: CONCOURSE ONE AT THE PALOMAR FORUM 2ND FL .16 FOR 1500 SQ FT GROUP 1 'Utility Report: Equivalent K-Factor Calculator Node Sprinkler Pres. Dia. Pipe Ftgs. Total H-W Equivalent Name K-Factor (psi) (in) Len. (ft) Len. (ft) coef. K-factor ANY 5.60 7.00 1.080 ----------------------------------------------------------------------- 0.33 T 5.33 120.00 5.47 Equivalent K-Factor Calculator Node Sprinkler Pres. Dia. Pipe Ftgs. Total H-W Equivalent Name K-Factor (psi) (in) Len. (ft) Len. (ft) coef. K-factor ANY ---0 7.00 1.0 0.33 ---.33 120.00 5 1ieduIe4O7SchedüIe-40° Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get UL listed and FM approved product. Although these products do not require separate approvals, Schedule-1O/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1W- 8") pipe and Sch-40 (1"- 2W') pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-1O/Schedule-40 product NomlnalJ WtJPt Wt/Ft Pc./ WtIUft Wt,Uft Wt/Uft can be "hot-dip" galvanized to NPS I.D. 1120 Filled Lift 21' 24' 25' *25 _1.049J 26.61 1.680 2.5 2.05 3.05 70 70 2470 1.120 2822 1280 2940 1334 meet FM requirements for dry '- Systems in accordance with the zinc coating specifications of 1W 1.380 2.270 2.93 51 2431 2778 2894 ASTM A-123. *32 35.1 4.36 4.36 51 11.03 1260 131.3 x 1½" 1.610 2.720 3.61 44 2513 2872 2992 *40 40.9 4.0 5.37 44 1140 1303 1357 x 2" 2.067 3.650 5.13 30 2300 2628 2738 1.J.IrdTZ'?ThiL. Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color *50 52.5 5.4 7.63 30 1043 1192 1242 *2W 2.469 5.790 7.86 19 2310 2640 *65 62.7 8.6 11.73 19 1048 1197 2750 1.247 applications Without special preparation. f3 Specifications____ ['Irr s x=Inches *=Metric Product Ncnhial WVFt Wt/Ft Pc/ Wt/LWt Wt/Uft Wt/Uft Tiirur*riu FTr NPS I.D. 1420 Filled LIft 21' 24' 25' X r *25 1.097 27.9 1.400 2.1 1.81 2.70 91 91 2675 121.3 3053 1.385 3185 1.445 Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. 1W *32 1.442 36.6 1.810 2.7 2.52 3.75 61 61 2319 1.052 2664 1208 2760 1.252 X 1½" 1.682 42.7 2.080 3.1 3.04 4.52 61 61 2664 1208 3045 1381 3172 1439 Specifications & Approvals *40 * 2" 2.157 2.640 4.22 37 2051 2344 2442 Schedule-1O/Schedule-40 pipe are in * 50 54.8 3.9 6.28 37 930 1063 1108 compliance with the following: x 2½" 2.635 3.530 5.89 30 2224 2542 2648 ASTM A-135, and NFPA 13. *65 66.9 5.3 8.77 30 1009 1.153 1.201 3.260 4.330 7.94 1.9 1728 1975 2057 Both pipe products have a working pressure rating of 300 psi maximum and also *80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 1.1.78 19 2238 2558 2665 meet the stringent requirement for the following tests: *90 108.2 8.3 17.53 19 1015 1160 1209 * 5" *125 5.295 134.5 7.77 11.56 17.33 25.80 10 10 1632 740 1865 846 1943 881 Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test (!j) . __ - Ld 6" * 150 6.357 161.5 9.290 13.8 23.03 34.27 10 10 1951 885 2230 1012 2322 1053 8' 8.249 16.490 40.15 7 2424 2770 * 200 209.5 24.5 59.75 7 1100 1256 2885 1309 (;I dhed 16100 S. Lathrop 11350 Norcom Rd. 2525 N. 7th Ave. Custo,na,S.nlc.: Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 1.800.882-5543 Fax 708-339.1806 S4-17