HomeMy WebLinkAbout2523 NAVARRA DR; ; FA070038; Permit1/9/25, 9:03 AM FA070038 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2523 NAVARRA DR Permit Type: FALARM Parcel No: 2161702000 Lot #: 0 Reference No.: Permit No: FA070038 Status: ISSUED Applied 3/27/2007 Approved: 3/27/2007 Issued: 3/27/2007 PC #: Inspector: Project Title: MATCHPLAY AT LA COSTA TWO FIRE ALARM INSPECTIONS AT $62/EA Applicant: CLS SECURITY ELECTRONICS SUITE D 9295 CHESAPEAKE DR SAN DIEGO, CA 858-654-2788 Owner: CREWS MICHAEL COMMERCIAL DEVELOPMENT P 0 BOX 300429 ESCONDIDO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) L1Ii1 LI_124IL about:blank 1/1 MATCHPLAY 2523 NAVARRA DR. LA COSTA, CA 92008 Fire Alarm Submittal 3/5/07 ,. tø 100 V" \' \ S S •. ç U APPROVE 7S'PIUBMI ED EN - Submitted By; CLS Security Electronics Contact: Dan Dorgan 9295 Chesapeake Dr. San Diego, CA. 92123 License #675676/Type C 10 'S..., MATCHPLAY Fire Alarm Submittal Equipment List -Qty Description 1 Fire Alarm Panel 1 Fire Alarm Annunciator 1 Smoke Detector 1 Heat Detector 1 Manual Pull Station 1 Horn/Strobe Model Manufacture CSFM# 5208 Silent Knight 7165-0559:137 5235 Silent Knight 7165-0559:137 4W-B System Sensor 7272-1653:152 5601P System Sensor 7270-1653:167 BG-12 Silent Knight 7150-0075:184 AS-24MCW WHEELOCK 7125-0785:131 Connection to existing water flow Connection to existing piv sw. Existing 120Vac Fire Alarm Bell Provided and installed by Others Provided and installed by Others. Provided and installed by Others. Lot Wire 14/2 Cond. (Notification) Lot Wire 18/2 & 18/4 Cond. (Initiation) Lot Wire 18/4Cond. (Annunciator) Lot Wire 2414 THWN (Underground) Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features Specifications 10 zones, 8 Class B (Style B) and 2 Operating Class A (Style D) or Class B (Style Voltage: 24 VDC B) zones, expandable to 30 zones Primary AC: 120 Vrms @ Supervised zone expanders and I/O 60Hz, 2A modules can be mounted remotely Total DC Load: 6 Amp from the main control panel Event History Buffer (150 events) Current Draw: with date/time stamp Standby: 140 mA All zones are compatible with 2- or Alarm: 460 mA 4-wire detectors Flush Mount 8 selectable/programmable output Dimensions: patterns for notification appliance Height: 24.75" (62.9 cm) circuits Width: 14.5" (36.8 cm) Built-in Digital Alarm Communicator Depth: 3-7/16" (8.73 cm) with 5/8" protruding Transmitter (DACT) Overall 4 Notification Appliance Circuits Dimensions: 4 programmable general purpose Height: 26-3/8" (67 cm) relays Width: 17-3/16' (43.66 cm) Programmable smoke verification, Total Depth: 4" (10.16 cm) JI[k•. pre-alarm delay, cross zoning and __________ -' enhanced verification mode features Operating Temp: 32° to 120° F that can help minimize false alarms (0° to 49° C) p: Programmable from the built-in ccntrol panel touchpad, remote Optional Accessories Listings and Approvals annunciator, or Windows® . SK-5235 LCD Remote Annunciator . UL Listed downloading software SK-5217 10 Zone Expander ° CSFM Listed Direct connect port for on-site (2 max. per system) MEA approval 429-92-E Vol. XIII up/down loading with Windows® SK-5280 Status Display Module (8 downloading software max. per system) Built-in walk test feature 7181 Fire Zone Converter Single or Dual Interlock water 5220 Direct Connect Module SILENT releasing capability SKSS Downloading Software KNIGHT D A HOneywoIICompny Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect For On-Site Programming 2 Class A (Style D) or Class B (Style B Initiation Circuits 8 Class B (Style B) , Initiation Circuits Programmable Form C Relays Notification Appliance Circuits 5235 Remote Annunciators =ann SBUS Devices, 5280 and 5217 To AC D SILENT KNIGHT A Honeywell Conpany 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350318, Rev. 01/04 Copyright © 2004 Silent Knight Model SK-5208 Fire Control/Communicator Installation and Operation Manual Table 3-2: Current Draw Calculations - Device . # of Devices . Current per Device Standby Current Alarm Current For each device use this tnnmüa. I his columh V This cojutnu = (. urrent per mimh r ot de. ices SK-5208 Fire Panel (Current draw from battery) 1 Standby: 140 mA 14() mA Alarm: 460 mA 460 mA Panel Accessories SK-52 17 Zone Expander (2 max.) Standby: 60 mA mA A1n. 260 mA mA 5824 Serial-Parallel Interface Gateway Module Standby: 45 mA mA Alarm: 45 mA mA 5220 Direct Connect Standby- 15 mA mA Alarm: 15 mA mA SK-5235 Annunciator (6 max.) Standby: 30 mA m \ Alarm: 50 mA mA SK-5280 Status Display Module (8 max.) Relay (max.) Standby: 10 mA mA Alarm: 80 mA mA outputs Per output 100 mA mA Max. 700 mA mA 7181 Zone Converter Standby: 35 mA mA Alarm: 65 mA mA Total System Current Smoke Detectors Standby: mA mA Alarm: mA mA -Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm mA mA Smoke Detector Current mA mA \otitication Appliances Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Additional Devices Standby: mA Alarm: mA Standby: mA Alarm: mA Additional Devices Current mA Total current ratings of all devices in system (line A + line B + C +D) mA mA Total current ratings converted to amperes (line E x .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): H Multiply lines F and G. Total standby All AH Alarm sounding period in hours. (For example, 5 minutes .0833 hours) . H Multiply lines F and 1. Total alarm All AH Total ampere H and J. hours required AH*Add lines Use next size battery with capacity greater than required. 3-6 P/N 151204 A I:] C D E F G H 94 Control Pane! Installation 36.3 Maximum Battery Standby Load Table 3-3 shows the maximum battery standby load for the SK-5208 based on 24 and 60 hours of standby. The standby load calculations of line D in the Current Draw Calculation Worksheet (Table 3-2) must be less than the number shown in Table 3-3 for the battery size used and standby hours required. Batteries larger then 18 AH will not fit into the SK-5208 cabinet and must be housed in the AB-33 Accessory Battery Cabinet. See Section 3.8 for battery installation. Table 3-3: Maximum Battery Standby Load Rechargeable Battery Size Max. Load for 24 hrs. Standby, 5 mins. Alarm *Max Load for 60 hrs. Standby, 5 mins. Alarm 7 A 27O mA 105 mA 12 A 475 mA 190 mA 18 A 685 mA 270 mA 35 A 1.1A 450 mA * Requiredjor NFPA 72A uxiliaryProtectedFireAlarm systemsfor FireA farm Service (CityBox) andRemote Station Protected Fire Alarm systems (Polarity Reversal) and Digital Alarm Communicator/Transmitter (DA CT). Silent Knight does not support the use of batteries smaller than those listed in Table 3-3. If you use a battery too small for the installation, the system could overload the battery resulting in the installation having less than the required 24 hours standby power. Use Table 3-2 to calculate the correct battery amperes/hour rating needed for your installation. P/N 151204 3-7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:137 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Model *SK..5208 fire alarm control unit. Power-limited, automatic, manual, remote station, central station, waterfiow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: SK5208 Control Unit SK-5220 Direct Connect Module SK-5280 Status Display Module SK-5217 Zone Expander SK-5235 Remote Annunciator SK-2190 Enclosure SK-7181 Zone Converter INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturers Installation Manual for details. NOTE: 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Recell 08-17-2006 jew 11 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: AUGUST 17, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Models Available Two-Wire Models 2W-B 2-wire standard 2WT-B .. 2-wire standard with thermal Four Wire Models 4W-13 4-wire standard: . 4WT B 4-wire standard with thermal Accessories Product Overview Plug-in detector line - mounting base . System Sensor's P'" series smoke detectors represent a significant advancement in Included conventional detection. The P family is founded on three principles: installation ease, Intelligence, and Instant Inspection.. Large wire entry port Installation ease. The i3 line redefines installation ease with its plug-in design. In-line terminals with SEMS screws This allows an installer to pre-wire the bases included with the heads. The large Mounts to octagonal and single-gang wire entry port and in-line terminals provide ample room for neatly routing the backboxes, 4-square backboxes or , wiring inside the base. The base accommodates a variety of back box mount- direct to ceiling ing methods as well as direct mounting with drywall anchors To complete;•.... the installation, i3 heads plug-in to the base with .a simple Stop-Drop 'N Lock Stop-Drop 'N Lock'" attachment to base action. Removable detector cover and chamber Intelligence. i3 detectors offer a number of intelligent features to simplify for easy cleaning testing and maintenance. Drift compensation and smoothing algorithms are standard with the 3 line, to minimize nuisance alarms. When connected to the Built-in remote maintenance signaling 2W-MOD2 loop test/maintenance module, or a panel equipped with the i3 protocol, 2-wire i3 detectors are capable of generating a remote maintenance Drift compensation and smoothing signal when they are in need of cleaning. This signal is indicated via an LED algorithms located at the module and the panel. To read the sensitivity of i3 detectors, the SENS-RDR is a wireless device that displays the sensitivity in terms of percent Simplified sensitivity measurement per foot obscuration. Wide angle, dual color LED indication Instant inspection. The i3 series provides wide angle red and green LED indica- tors for instant inspection of the detector condition, indicating: normal standby, Loop testing via EZ Walk feature out-of-sensitivity, alarm, or freeze trouble conditions. When connected to the Built-in test switch 2W-MOD2 loop itesvmamtenance module or a panel with the i3 protocol,. • the EZ Walk loop test feature is available on 27wire i3 detectors. This feature FM 2 MEA .. verifies the initiating loop wiring by providing LE D status indication at each MSFM lSTEO . approved .,approved . S911 30114-48 7272-1209:210 29001-E 2093 Architect/Engineer Specifications Smoke detector shall be a System Sensor with a plaster ring, or direct mount to the The detector shall provide dual color LED i3 Series model number_, listed to ceiling using drywall anchors. Wiring con- indication which blinks to indicate power derwriters Laboratories UL 268 for Fire nections shall be made by means of SEMS up, normal standby, out of sensitivity, )tection Signaling Systems. The detector screws. The detector shall allow pre-wiring alarm, and freeze trouble (model 2WT-B, shall be a photoelectric type (model 2W-B, of the base and the head shall be a plug- 4W7-B) conditions. When used in conjunc- 4W-B) or a combination photoelectric/ in type. The detector shall have a noini- tion with the 2W-MOD2 module, 2-wire thermal (model 2WT-B, 4WT-B) with ther- nal sensitivity of 2.5% per foot nominal models shall include a maintenance signal mal sensor rated at 135°F (57.20C). The as measured in the UL smoke box. The to indicate the need for maintenance at the detector shall include a mounting base for detector shall be capable of automatically alarm control panel, and shall provide a mounting to 31h-inch and 4-inch octagonal, adjusting its sensitivity by means of drift loop testing capability to verify the circuit single gang, and 4-inch square back boxes compensation and smoothing algorithms, without testing each detector individually. Electrical SDeclfications Operating Voltage Standby Current Peak Standby Current Nominal: 12/24V non-polarized 2-wire: 50 pA maximum average 2-wire: 100 pA Mm.: 8.5V 4-wire: 50 pA maximum average 4-wire: n/a Max.: 35V - Maximum Alarm Current Alarm Contact Ratings Maximum Ripple Voltage 2-wire: 130 mA limited by control panel 2-wire: n/a 30% peak to peak of applied voltage 4-wire: 20 mA @12V, 23mA @ 24V 4-wire: 0.5 A @ 30V AC/DC Condition Duration Initial LED status indication 80 seconds LED Mode Green LED Power up Blink every 10 seconds Normal (standby) Blink every 5 seconds Out of sensitivity off Freeze trouble off Alarm off -. fslcal Specifications rating Temperature Range B and 4W-B: 32°F-120°F (0°C-49°C) 2WT-8 and 4WT-B: 32°F-100°F (0°C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-8 and 4WT-B only: 41°F (5°C) Red LED Blink every 10 seconds off Blink every 5 seconds Blink every 10 seconds Solid Sensitivity 2.5%/ft. nominal Input Terminals 14-22 AWG Dimensions (including base) 5.3 inches (127 mm) diameter 2.0 inches (51 mm) height Weight 6.3 oz. (178 grams) Mounting 3w-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Ordering Information Model Thermal I Wiring Alarm Current 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12V, 23mA @ 24V 4WT-8 Yes 4-wire 20 mA @ 12V, 23mA @ 24V Model Description 2W-MOD2 2-wire loop test / maintenance module SENS-RDR Sensitivity reader RT Removal / replacement tool A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter tern Sensor Sales and Service - em Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377.6495 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.891920 Fx: 441403.891921 System Sensor In China System Sensor - Far East Ph: 8629.8832.0119 Ph: 85.22191.9003 Fx: 86.29.8832.5119 Fx: 85.22.736.6580 System Sensor in Singapore System Sensor - Australia Ph: 65.62732230 Ph: 613.54.281.142 Fx: 65.6273.2610 Fx: 613.54.281.172 System Sensor - India Ph: 91.124.237.1770 x.2700 Fx: 91124.237.3118 System Sensor - Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 0 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0318-005.6/04.#1280 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE STING No. 7272-1653:152 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Tnsh Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 2W-13, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-13 and 4WT-B are 4-wire detectors. Models 2Wr-B and 4WT-B employ a thermistor type heat sensor (1350 F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. RKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. )ate Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 'STF' 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations- - Single- and dual-circuit models - Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601 P) Easy-to-use terminal screws A broad range of back box mounting options: - Single gang - 3.5' and 4" Octagonal - 4' square with square to round plaster ring Reversible mounting bracket Agency Listings ®MEA 0 LISTED AppRovm approved Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility.To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal hack boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations, Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the oroper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. ions Mechanical heat detector shall be a System Sensor 5600 series model number __________ listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type, normally open.The detector shall be rated for activation at either 135°F (51°C) or 194°F (90°C)aid shall acuvateby inverts ole fixed letriperesure thermalset isor,ur acurribirrauurt fixed Let nperature/rate-ol- rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 5°F (83°C) per minuteThe detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identity its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for deld-testing The detectors shall include an external collector that shall drop r ipon activation to identify the unit in alarm. - -. Maximum Installation Temperature 5601P, 5603, 5621,and 5623: 100°F (38xC) 5602, 5604,5622, and 5624:150'F (65.6°C) Operating Humidity Range S to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602,5604, 5622, and 5624:194'F (90°C) Weight 6 oz. 070 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601 P, 5602,5621 and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring - - - Operating Voltage / Contact Ratings 6-1 2SVAC / 3A 6-28VDC/ 1A 125VDC / 03A 2SOVDC/01A Input Terminals 14-22 AWG 5601 P 5602,5622 5603,5623 5604,5624 5621 trdering Information iIipt WT on E,or Rbn AThion 5601P Single None 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 fees x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) . Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24mx15.2m( 5603 Single Lettering 135°F (57°C) Fixed Temperatu re 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 762m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature /Rate-of-Rise 50feetx50 fee: (15.24m x 152m) 5622 Dual Lettering 194°F (90°C) Fixed Tenperature / Rare-of-Rise 50 feet x 50 feet (ls.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature 25 feet 25 feet (7.62m x 7.62m( °NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet SYSTEM 3825 Ohio Avenue St. Charles, IL 60174 $ SEftJSOR Phone: 800-SENSOR2. Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE STING No. 7270-1653:167 Page 1 of 1 CATEGORY: Heat Detector LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 5601, 5601 P, 5602, 5621, and 5622 combination fixed-temperature and rate-of- rise type and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models Fixed Temperature Electrical 5601, 5601P 135°F 6-125V AC, 3A 5602 194°F 5603 135°F 6-28V DC, IA 5604 194°F 11 5621 135°F I25V DC, 0.3A 5622 194°F 5623 135°F 25OV DC, 0.1A 5624 194°F 11 ..'STALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7270-1209:227 06-20-05 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation Vt criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. )ate Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager FIreLrre arms www.firelite.com GENERAL The Fire-Lite Alarms BG-12 Series is cost-effective, fea- ture-packed, non-coded series of manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of models including single- and dual- action versions. The BG-12 Series provides Fire-Lite Fire Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (single- or dual-action), yet designed to prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. Station can be opened for inspection and maintenance without initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located in- side). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (IC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.25 mm2). July 14, 2004 1 DF-52004 F-050 BG-12 Series Manual Fire Alarm Pull Stations Section: Conventional Initiating Devices c®Us California State Fire Marshal 7150-0075:184 LISTED <9> MEA 67-02-E APPROVED Terminal numbers are molded into the backplate, elimi- nating the need for labels. Switch contacts are normally open. Can be surface (with SB-I/O or SB-b) or semi-flush mounted. Semi-flush mount to a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by up to 1/2" (12.7 mm). Optional trim ring (BG-TR). Spanish version (FUEGO) available (BG-1 2LSP). Designed to replace the Fire-Lite Legacy BG-10 Series. Models packaged in attractive, clear plastic (PVC), clamshell-style, Point-of-Purchase packages. Packag- ing includes a cutaway dust/paint cover in shape of pull station. FlreLIte® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep IS09001 our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to d I I change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, NfERJNC & MAMIF*CTIIING QUALITY SYSTEMS Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. IJr-Jzvu, 'JI I 1fVW - rav , UP c CONSTRUCTION Cover, backplate and operation handle are all molded of durable polycarbonate material. Cover features white lettering and trim. Red color matches System Sensor's popular SpectrAlert horn/strobe series. OPERATION The BG-12 manual pull stations provide a textured finger- hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking persons. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key or hex (model dependent), twist one quar- ter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: ties Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE/FUEGO"on the BG-I2LSP shall ap- pear on the front of the station in white letters, approximately 3/ 4" high. PRODUCT LINE INFORMATION Model Description BG-12S Single-action pull station with pigtail connec- tions, hex lock. BG-I2SL Same as BG-12S with key lock. BG-12 Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock. BG-12L Same as BG-12 with key lock. BG-I2LSP Same as BG-12L with English/Spanish (FIRE/FUEGO) labeling. BG-I2LOB Same as BG-12L with "outdoor use" listing. Includes outdoor listed backbox, and seal- ing gasket. BG-12L0 Same as BG-12L with "outdoor use" listing. Does not include backbox. BG-I2LA Same as BG-12L with auxiliary contacts. BG-I2LPS Same as BG-12L with presignal feature. BG-I2LPSP Same as BG-I2LPS with English/Spanish (FlRE/FUEGO) labeling. SB-I/O Indoor/outdoor backbox. SB-10 Indoor use backbox. WP-10 Outdoor use backbox. WBB Outdoor use backbox. 17003 Key lock. 17007 Hex lock. izl qj Ii.n S8410 SB.10 VP-10 VMB 5.5irdes 51 iidEs 55irs &Oirds 4.25 irds (lag? ar (14Z OT (1397 an) (1524 ar (10.79 aT 4.121 irr*s 4M irds 4.121 irds 4.69 irdies 4.25 irds VWft - (10.47ar (10.72 or (1047 all (11.91 all (10.79ar ___ 1.39 irds 1.439iritEs 1375 in±Es 2.0irdes 1.75 1ntEs (3S3on 3.69an (a490ll (5.O8aTU (4.445all 52004t1.tb1 Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A © 30 VAC orVDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition it- self so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall ap- pear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for sur- face mounting on matching backbox SB-10; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabili- 1.390" (35.306) Wire Length Strip Gauge T 1.000" (25.40) 0.750" (19.05) 5.500" (139.70) (mm) Page 2 of 2 - DF-52004 '07/14/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE STING No. 7150-0075:184 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: Fire-Lite Alarm Inc., One Fire-Lite Place, Northford CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models BG-12, BG-125, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-I2LX, BG-12LA, BG-I2PS, BG-I2LSP, BG-I2SP, BG-I2LR, BG-I2LRA, BG-I2LAO, BG-I2LAOB, BG-12-LO, BG-I2LOB, BG-12LPS, BG-12LPSP, BG-12SL, *uT..PSI and UT- PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. 'PROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-12LW and BG-12L\NP are intended for outdoor use when installed with Model WP-1 0 back box. Models BG-LAOB and BG-1 2LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. XLF: 7150-0028:199 *Rev. 05-06-05 JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager COOPER Wheelock Series AS Audible Strobe Appliances and Series AH Auddibles SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75195cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-24-81VIC Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPNUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75195cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18AWG wires For Weatherproof Senes AS, See Dat asheet S9004 nYU0L =T- 0.163 0.260 0.192 0.320 High (99) cIBA Umax" Med (95) 12 vdc 0.076 0.195 UL max* 0.108 0.275 dBA 12 vdc; 0.039 0.175 UL max* 0.058 0.265 24 VDC Models High (99) 24 vdc dBA ULmax" Med (95) 24 vdc dBA UL max* Low (90) 24 vc [ULmdax- dBA 12 VDC Models Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models AH-24 AS-241576W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd IlOccI 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 Audible Wall Mount Audible Strobe AH-12 I AS-121575W Table 4: Average Current*(AMPS) For Series ASWP# Voltage High dBA Setting (99)dBA Medium dBA Setting (95)dBA Low dBA Setting (90)dBA 24.0 VDC 0.128 0.105 0.098 ULMax* 1 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS currentwithin the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. ('--raI Notes: robes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH homs are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 464 dBA @10 ft. @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Code 3 Horn Medium 84 95 Low 79 90 Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15(75onAxis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0-33.0 75@-31°F Tht 3: Average RMS Current Wring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT PRECEDING + OR EOLR APPLIANCE. APPLIANCE OR FACP ::+f SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12/244CP and PS-12/24-8MP AS OUTPUTS IMP F 4-CLASS 1-4 A OR 2-CLASS C P SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE SM ± STROBE it- robe - STROBE [i circuit (ZL_ Mid ible - Audibi NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 I esP1V28CP SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE SM Interconnecting wiring shown. Maximum of twenty (20) For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-81VIC. Specifications and Ordering Information Model Number Order Code Strobe Candela Non Sync Sync wISM, DSM or PS-24-8MC 24 VDC 12 VDC Wall Mount Ceiling Mount Mounting Options Agency Approvals - UL - MEA - CSFM - FM - BFI S-24MCW-FR 9024 15/30/75/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X S-24MCW-FW 9025 1 15/30/75/110 X X X - - A,B,D,E,F,G,H,J,N,OR,X X X X X X S-24MCWH-FR 3468 135/185 X X X - - AB,D,E,F,G,H,J,N,O,R,X X X X X * \S-24MCWH-FW 3469 135/185 X X X - X - AB,D,E,F,G,H,J,N,O,R,X X X X X * AS-241575W-FR 7405 15(75onAxis) X X X - X - A,B,D,EF,G,H,J,N,O,R,X X X X X X \S-121575W-FR 7410 15(75 on, Axis) X X - X X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X \S-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,NORX X X X X * \S-24MCC-FW 3162 15/30/75/95 X X X - . - X A8,D,E,F,G,HJN,O,R,X X X X X * S-24MCCH-FW 3467 115/177 X X X - - X AB,D,E,FG,H,JN,O,R,X X X I X X * SWP2475WFR** 9012 75 @ -31°F X X X - X - I (see Data Sheet S9004) X X X X X H-24-R 7892 - X X X - X X A,BD,E,FGH,JN,O,R,X X X X X X \H-24-W 7893 - X X X - X X A,B,D,EF,G,H,JNO,R,X X X X X X H-12-R 7891 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X H-1 2-W 7894 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X -24WP-R° 7416 - X X I X - X X K X X X X 12 R°° 7415 - X X X I X X I K X X X ::For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING *Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. - Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). udible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice itinuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock PS-24-8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash- rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, orthe SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. 2 anchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooQerwheelock.com I1!ZA4 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE STING No. 7125-0785:131 Pagel of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -Ware for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model AS\NP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix Ware for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. *Rev. 06-13.06 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models Al-l-12WP and AH-24WP audible appliances are suitable for indoorloutdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager