Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6221 METROPOLITAN ST; ; AS090096; Permit
12/13/24, 3:58 PM AS090096 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090096 6221 Job Address: METROPOLITAN ST Permit Type: SPRINK Parcel No: 2132600100 Lot #: 0 Reference No.: Status: PENDING Applied 8/18/2009 Approved: Issued: PC #: Inspector: Project Title: DR. SHEIK'S DENTAL STE. 202 Ti. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 1IAAA II1 I' BRESSI RANCH MEDICAL PLAZA L L C DAVID DIRIENZO 1280 BISON AVE #B9-609 NEWPORT BEACH CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 San Diego Branch Office .*0006 6 . 1 COSCO 10695 Treena Street, Suite #105 San Diego, CA 92131 Protecti on (858) 444-2000 fax: 444-2056 IL I LL IL State License No: C-16-577621 www.coscofire.com MATERIAL SUBMITTAL Date:8/17/2009 DR SHIEKH DENTAL OFFICE 'vo~ 221 METROPOLITAN ST STE 205- CARLSBAD CA 92009 JOB # 0908-0600 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: ALE Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle August 4, 2006 Sprinkler 41 a PRODUCT NAME MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS tThe Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 Technical Services: (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com PRODUCT DESCRIPTION Viking Microfast® and MicrofastHP®Quick Response Pendent Sprinklers are small thermosensitive glass bulb spray sprinklers available in various finishes, temperature ratings, and orifice sizes to meet design requirements. The special Poly finishes and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these finishes have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Poly finishes as corrosion resistant.) The pip cap and sealing assembly of the sprinkler are held in place by the glass bulb operating element. During fire con- ditions, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. TECHNICAL DATA LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 Refer the Approval Chart on page 41 c and Design Criteria on page 41 d for cULus and FM approval requirements that must be followed. CHARACTERISTICS Minimum Operating Pressure: 7 psi (0,5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0,5 bar) up to 250 psi (17,2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34,5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart MATERIALS Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Note: Units of measure in parentheses may be approximations. Replaces page 41 a-b, dated November 18, 2005 (Reformatted, added Form No. F_081296 135 °F temperature rating, and added CE approval for sprinkler 066668.) Sprinkler 41 b August 4, 2006 MICROFAST® AND MicrofastHPO N I KJ QUICK RESPONSE PENDENT SPRINKLERS vt:ii TEMPERATUREI Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 °F (57 °C) 100 ¶ (38 °C) Orange Ordinary 155 ¶ (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 C) Yellow Intermediate 200 °F (93 °C) 150 ¶ (65 °C) Green High 286 °F (141 °C) 225 ¶ (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester (White Poly finish for Sprinkler 06662B), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® Corrosion-Resistant Coatings3: White Polyester (White Poll finish for Sprinkler 06662B only), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corosion test required by the approving agencies indicated on page 41 c. These tests cannot and do not represent all possible corrosive envionments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprhklers with Poly finishes and Teflon® coatings. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel For Teflon® Coated Sorinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Poly Coated Sprinklers: Belleville Spring-Exposec AVAILABLE FINISHES AND TEMPERATURE RATINGS Refer to Table 1 above. 5. ORDERING INSTRUCTIONS (Also refer to the current Viking price list.) Order Microfast® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprnkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Poly Finish = M-/W, Black Poly Finish = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135/68 =A, 155°/68 = B, 175°179 = D, 200/93 = E, and 286°/141' = G For example, Sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06662BAB. ACCESSORIES (Also refer to the 'Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: Recessed pendent sprinklers with protective caps must use wrench 12144W/B. **A /2" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) August 4, 2306 Sprinkler 41 c Approval Chart KEY Microfast and MjcrolastHP7 Quick Response Pendent Sprinklers Maximum 175 PSI (12,11 bar) WWP Base Part Thread Size Nominal Overall Length Listings and Approvals3 Number SIN K-Factor (Refer also to Design Criteria on page 41 d.) NPT I BSP I U.S. I metriC2 1 Inches I mm I cULus4 I FM5 I NYC6 IVdS I LPCBI CE I Standard Orifice 06662B VK302 1 1/2" 115 mm 1 5.6 I 80,6 1 2-1/4 58 IA1X, B1YIA4X, B4YIA1X, BIYI F2 I A4X IC4X, D4Y121 C4X, D4Y14 Large Orifice 066668 VK352 3/4" 20 mm 8.0 115,2 2-3/8 60 A3X, B3Y A2X, B2Y A3X, B3Y -- E412 -- 12104 1 VK352 3/4" 120 mm 8.0 115,2 2-1/4 58 1 -- -- -- F2 I -- -- 06765B VK352 1/2" 15mm 8.0 115,2 1 2-3/8 1 60 IA3X,B3YI -- I A3X,B3YI -- -- -- _________ Small Orifice8 06718139 VK329 1 1/2" 15 mm 2.8 40,3 2-3/16 1 56 1 A3X, B3Y I A2X A3X,B3YI I -- -- -- 0672069 VK331 1 1/2" 115 mm 1 4.2 1 60,5 2-1/4 1 58 IA3X,B3YI A3X,B3YI I -- -- -- 06932B VK331 I -- 1 10 mm 1 4.2 1 60,5 2-3/8 1 60 1 -- -- -- F2 -- F213 -- Maximum 250 PSI (17,2 bar) WWP Standard Orifice Base Part Thread Size Nominal Overall Length Listings and Approvals3 Number' SIN K-Factor (Refer also to Design Criteria on page 41 d.) NPT BSP U.S. I metric' Inches I mm cULus4 FM I NYC10 JVdSlLPCB CE 12282 VK317 1/2" 15mm 5.6 80,6 2-1/4 1 58 A3X,B3YJ A3X I .-- -- -- -- Maximum 250 PSI (17,2 bar) WWP Small Orifice8 122909 IVK342I 1/2"I 15 mmI 2.81 40,3 2-3/16 I 56 IA3x,B3YI -- I A3X I -- I -- -- I -- Approved Temperature Ratings A- 135°F (5 71 °C), 155°F (68 °C), 175°F (79 °C), Approved Escutcheons 200 °F (93 °C), and 286 °F (141°C) Approved Finishes x - Standard surface-mounted escutcheon B -135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 1 - Brass, Chrome-Enloy®, White Poly Finish7, or the Viking Microfast® Model F-i and 200 °F (93 °C) Black Poly Finish7, and Black Teflon®7 Adjustable Escutcheon" C -155°F (68 °C), 175°F (79 °C), 200°F (93 °C), 2 - Brass and Chrome-Enloy® Y - Standard surface-mounted escutch- and 286 °F (141°C) 3 - Brass, Chrome-Enloy®, White Polyester7, eon or the Viking Microfast® Model D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F Black Polyester7, and Black Teflon67 F-i Adjustable Escutcheon" or re- (93 °C) 4 - Brass, Chrome-Enloy®, White Poly Finish, cessed with the Viking Micro- E - 155 °F (68 °C), 175 °F (79 °C), and 286 °F and Black Poly Finish matic® Model E-i or E-2 Recessed (141°C) Escutcheon F - 155 °F (68 °C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. The sprinkler orifice is bushed. 10Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol XVI. The Viking Microfast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13(( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130. 14 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. Sprinkler 41 d August 4, 2006 DESIGN CRITERIA (Also refer to the Approval Chart on page 41 c) cULus Listing Requirements: Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards beirg applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Aøoroval Requirements: Quick Response Pendent Sprinklers are FM Approved as indicated in the Approval Chart for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems). For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstruct ons, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Pleniere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Wrench 12144W/B** for , installing coated and/or L_~:recessed sprinklers ______ P' with protective caps Carefully slide the wrench sideways around the protective **A 1/2" ratchet is required cap, ensuring engagement (not available from Viking). with the sprinkler wrench flats. Figure 2: Wrench 12144W/B for Installing Coated and/or and Recessed Pendent Sprinklers August 4, 2006 Sprinkler 41 e MICROFAST® AND QUICK RESPONSE PENDENT SPRINKLERS Ceiling Opening Size: 2-5/16" (59 mm) Minimum, I 2-1/8 • I 2-1/2" (64 mm) Maximum. (54 mm) 1/2"—\ (15 mm) NPT _____ _______ 2-1/4" 1-3/4" (58 mm) (44,5 mm) Pendent Sprinkler 06662B 1-3/4" (44,5 mm) Pendent Sprinkler 06662B Installed with a Standard 1/8" (3,1 mm) Surface-Mounted Escutcheon W 1-1/2" 2" (50,8 mm) (38,1 mm) Maximum Mininum Pendent Sprinkler 06662B Installed with the Microfast5 Model F-i Adjustable Escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: I 21/8" I 25/16" (59 mm) Minimum, l (54 mm) 2-1/2" (64 mm) Maximum. 2-1/8" (54 mm) 1-1/8" (28,6 mm) Minimum (44,5 mm) Maximum Pendent Sprinkler 06662B Installed with the Micromatic® Model E-1 Recessed Escutcheon 2" 1-1/8" (28,6 mm) (50,8 mm) Minimum Maximum ~2 ___________ Pendent Sprinkler 06662B Installed with the Micromatic® Model E-2 Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons THIS PAGE INTENTIONALLY LEFT BLANK Replaces page 41 a-b, dated November 18, 2005 (Reformatted, added Form No. F_081296 135 °F temperature rating, and added CE approval for sprinkler 06666B.) With ABF' C)Pr0tect r) IJuI. MMM II,I'I Schedule-1O/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch- 10 (1'/4"- 8") pipe and Sch-40 (1"- 214") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule- 10/S chedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "AB]"'. In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Sch-40 Specifications NPS Nominal I.D. WI. WI. (1120 Filled) Pc WI/lift (21 ) WI/Lift (24) WI/Lift (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11,4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1½" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2' 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pc Wt/Lift (21) WI/lift (24) WI/Lift (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs, Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4" 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 11/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule- 10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tilCO/Flow Control Qr allied TUBE & CONDUIT Listed Approved Listed 16100 S. Lathrop Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5-3 11.02 VIC IAULIC° IS AN ISO 9001 CERTIFIED COMPANY Styles 920 and 920N Mechanical-T® Bolted Branch Outlets PRODUCT DESCRIPTION Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position . permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized housings are available, supplied with plated bolts. Styles 920 and 920N All sizes of Style 920 and 920N are rated at 500 psi (3450 kPa) working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or polybutylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. #Styl. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. 920 Cross See Victaulic publication 10.01 for details. See c/ta/I on page 4 for pressure re/frogs. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-395, grade 65-45-15, and ASTM A-536, grade 65-45-12, with orange enamel coating. Optional: Hot dipped galvanized Gasket: (Specify choice°) Grade 'E" EPDM EPDM (Green color code). Temperature range -30°F to +230°F (-34°C to + 110°C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F (+30°C) and hot +180°F (+82°C) NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range -20°F to +180°F (-29°C to +82°C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over -f 150°F (+66°C) or for hot dry air over +140°F (+60'C). *Services listed are General Service Recommendations only. It should he noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: (Styles 920 and 920N) Heat treated carbon steel zinc plated to ASTM B-633, track-head conforming to physical properties of ASTM A-183 minimum tensile 110,000 psi (758340 kPa). 91 REGISTERED TRADEMARK OF VICTAULIC - S COPYRIGHT 2003 VICTAULIC - PRINTED IN U.S.A. 1480 REAP Victaulic Company ol America • Phone: 1-800-PICK.VIC (1-800-742-5842). Fax: 610-250-881]• e-mail:pickvic@victaulic.com Victaulic Company of Canada Phone: 905-881-7444. Fax: 905-884-9774 e-mail: viccanada@victaulic.com Victaulic Europe. Phone:32-9-381.1500. Fax: 32-9-380-4138 e-mail: viceuro@victaalic.he Victaulic America [alma Phone: 610-559-3300 Fax:610-559-3608 e-mail:xical@vlclaallc.com Victaulic Asia Pacific Phone: 65-6235-3035• Fax: 65-6235-0535 e-mail: xlcap@victaullc.cxm tauii ZCc 1102 -Y F -r- Z ---, I LT Styles 920 and 920N w/Female Threaded Outlet NOTE: Style 920 and Style 920N housings cannot be mated to achieve cross connections. These new size Style NEW 920N products require a HOLE SIZE different hole size than the Style 920 it replaces, for proper installation. Use cautIon to assure the proper size hole is prepared for the specific size and style used. Failure to use the proper hole size could result in joint leakage and property damage. Max. Dimensions - Inches/millimeters - Aprx. SIZE Work. Wgt. Each Hole Fern. Run X Branch Press. Dia, Thd. Grv. Lbs/kg Fern. Nominal Inches Style PSI +0.13 V V RIM No. kPa -0.00 1• 8 f W Y Z Thd. Grv. 2 X '/(6) 920N 500 1.50 2.00 2.53 - 1.63 4.91 2.50 3.1 - 50 X 15 3450 38,1 51 64 - 41 126 64 1.5 -. (a) 920N 500 1.50 1.97 2.53 1.63 - X 20 3450 38,1 1 50 64 - 41 125 70 1,5 - X 1 (a) 920N 500 1.50 1.81 2.53 - 1.63 4.91 2.75 3.0 - X 25 3450 38.1 46 64 - 41 125 70 1,4 X 11/ (a) 5 920N 500 1.75 2.04 2.75 3.00 1.63 4.91 3.00 3.5 3.2 6 32 3450 41,5 52 70 76 41 125 76 1.7 1.5 X 11 /2 (a) 5 920N 500 1.75 2.03 2.75 3.12 1.63 4.91 3.25 3.6 12 X 40 3450 44,5 52 70 79 41 125 83 1,7 1,5 21/2 X 1/2 (a) 920N 500 1.50 2.21 2.74 - 1.82 5.14 2.75 3.0 - 65 X 15 3450 38.1 56 70 - 46 131 70 1,4 X 3/ (a) 920N 500 1.50 2.18 2.74 - 1.82 5.14 2.75 3.0 - X 20 3450 38,1 55 70 - 46 131 70 1,4 - X 1(a) 920N 500 1.50 2.06 2.74 - 1.82 5.14 2.75 2.9 - X 25 3450 38,1 52 70 - 46 131 70 1,4 X 1 /4 t (a) 920N 500 1.75 2.29 100 3.25 1.82 5.14 3.00 15 3.2 X 32 3450 44,5 58 76 83 46 131 76 1,7 1,5 X 11/2 t (a) 920N 500 2.00 127 100 3.25 1,82 5.14 3.25 16 3.3 X 40 3450 50,8 58 76 83 46 131 83 1,7 1,6 76,1 mm X /z (a) 920 300 1.50 2.22 2.75 .- 2.25 6.50 3.18 3.9 - 6 15 2065 38.1 56 70 - 57 165 81 1,8 X 920 300 1,50 2.19 2.75 - 2.25 6.50 3.18 3.9 - X 20 2065 38,1 56 70 - 57 165 81 1.8 - X 1(a) 920 300 1.50 2.07 2.75 - 2.25 6.50 3.18 3.8 - 5 25 2065 38,1 53 70 57 165 81 1,7 - X i'/,(a) t 920N 0 0 1 5.67 100 10 10 X 32 3450 44,5 57 76 83 49 144 76 1,6 1.5 X 11/2 (a) 920N 500 2.00 2.25 3.00 3.25 1.92 5.67 3.25 3.5 3.3 X 40 3450 1 50,8 57 76 83 49 144 83 1,6 1,5 3 X 1/ (a) 920N 500 1.50 2.53 3.06 - 2.29 5.75 2,75 3.4 80 X 15 3450 38,1 64 78 - 58 146 70 1,6 X 3/4 (a) 920N 500 1.50 2.50 3.06 - 129 5.75 2.75 3.4 - X 20 3450 38.1 64 78 58 146 70 1,6 X 1(a) 920N 500 1.50 2.37 106 - 2.29 5.75 2.75 3.3 - 5 25 3450 38.1 60 78 - 58 146 70 1,6 X 11/4 (a) 1' 920N 500 1.75 2.54 3.25 3.56 129 5,75 3.00 313 3.7 X 32 (b) 3450 44,5 65 83 90 58 146 76 1,8 1,8 X 11/2 (a) t 920N 500 2.00 2.77 3.50 3.56 2.29 5.75 3.25 4.1 313 X 40(t)) 3450 50,8 70 89 90 58 146 83 1,9 1,8 X 2 (a) 920N 500 2.50 2.74 3.50 3.56 2.29 5.75 3.88 4.9 4.6 X 50 3.150 63,5 70 89 90 58 146 99 2,3 2,1 31/2 X 2 920N 500 2.50 - - 6.30 3.88 3.8 90 X 50 3450 63,5 --62 160 99 -1.8 4 X V2 (a) 920N 500 1.50 3.03 -100 3.56 2.69 J3.72.44 6.69 2.75 3.7 X 15 3450 38,1 77 90 68 170 70 1,8 X (a) 920N 500 1.50 3.00 3.75 3.56 2.69 6.69 2.75 20 3450 38,1 76 90 68 170 70 1,8 X 1(a) 920N 500 1.50 2.88 3.56 - 2.69 6.69 2.75 3.6 - 5 25 3450 38.1 73 90 - 68 170 70 1,8 - 11/4 (a) t 920N X 32(b) 3450 44,5 78 96 102 68 170 76 1,9 1,8 X 11/2 (a) 5 920N 500 2.00 128 4.00 4.00 2.69 6.69 3.25 4.2 3.9 X 40(b) 3450 50.8 83 102 102 68 170 83 2,0 1,9 X 2 (a) t 920N 500 2.50 3.24 4.00 4.00 2.69 6.69 388 5.0 413 X 50 3450 63,5 82 102 102 68 170 99 2.3 2,1 X 2'/ (a) t 920 500 2,75 3.06 4.00 4.00 2.69 7.25 4.63 5.8 5.0 X 65 3450 69,9 78 102 102 68 184 118 2,6 2.3 5 76,1 mm 920 500 2.75 - .- 4.00 2.69 7.25 4.63 - 6.4 3450 69,9 - - 102 68 184 118 - 2.9 X 3(a) 5 920 500 3.50 3.50 4.50 4.13 2.69 7.25 5.25 8A '6A 6 80 3450 88,9 89 114 105 68 184 133 3,8 2,9 108,0 mm X 11/4 (a) 920N 3450 500 1.75 3.06 3.78 - 2.63 7.25 3.13 5.0 - X 32 44,5 78 96 " 67 184 80 2,3 X 11/ (a) 920N 500 100 128 4130 - 163 7.25 138 513 - X 40 3450 50.8 83 102 - 67 184 86 2,3 - Fable continued on page 3. See notes on page 3. DIMENSIONS Y r-r_ Z Styles 920 and 920N wlGrooved Outlet Styles 920 and 920N Mechanical-T® Bolted Branch Outlets ,V,Ff:~ Styles 920 and 920N w/Female Threaded Outlet i L : Dimensions - Inches/millimeters Aprx. SIZE Work. Wgt. Each Hole'- Fem. Run X Branch Press. Dia. Thd. Cry. LbsJkg Fern. Nominal Inches Style PSI +0.13 V V Actual mm No. kPa -0.00 T" 8 W Y Z Thd. Cry. 108,0 ram X 2 (a) 920N 500 2.50 3.24 4.00 - 2.63 7.25 4.00 5.6 - X 50 3450 63.5 82 102 - 67 184 102 2.5 - X 21/ (a) 920 500 2.75 3.06 4.00 - 2.63 7.25 4.41 5.6 - 9 3450 69,9 78 102 -- 67 184 1122,5- X 3(a) 920 600 3.50 - - 4.00 2.63 7.25 5.00 - 6.5 9 80 3450 88.9 - -. 102 67 184 127 3,0 5 x 1/7 (a) t 920 500 2.00 406 4.75 4.75 3.25 8.38 3.75 7.4 7,6 125 X 40 3450 50,8 103 121 121 83 213 95 3,4 3,4 X 2 (a) 1 920 500 2.50 4.06 4.75 4.75 3.25 8.38 4.38 8.2 8.0 X 50 3450 63,5 103 121 121 83 213 111 1 3,7 1 3,6 X 21/2 (a) t 920 500 2.75 3.81 4.75 4.75 3.25 8.38 4.63 8.3 7.9 X 65 3450 69.9 97 121 121 83 213 118 3,8 3,6 X 76,1 mm(a((b) 920 500 2.75 3.81 4.75 - 3.25 8.38 5.38 - - 3450 69,9 97 121 - 83 213 137 - X 3 (a) t 920 500 3.50 4.00 5.00 4.63 3.25 8.38 5.38 8.4 8.8 X 80 3450 88,9 102 127 118 83 213 137 3,8 4,0 1393 mrn X 11/2 t 920 500 2.00 4.06 4.75 - 3.25 8.38 3,75 7.4 -. X 40 3450 50,8 103 121 - 83 213 95 1 3,4 - X 2 t 20 500 2.50 4.06 4.75 - 3.25 8.38 4.38 8.3 X so 3450 63,5 103 121 -. 83 213 111 3.7 - X 76,1 mm (a)(b) 920 500 3.50 - - 4.63 3.25 8.38 5.38 - 8.8 3450 88,9 - -. 118 83 213 137 - 4,0 X 3 920 500 3.50 - - 4.63 3.25 8.38 5.38 -. 8.8 X 80 3450 88,9 -. -. 118 83 213 137 - 4,0 6 X 19 920N 500 1.75 - - 5.13 3.79 9.13 3.25 - 4.8 150 9 32(b) 3450 44,5 ..- -- 130 96 232 1 83 - 2,2 X 1V (a) 5 2 9 0N 500 2.00 4.40 5.13 5.13 3.79 9.13 3.25 5.4 5.1 X 40 )b) 3450 50,8 112 130 1 130 96 232 83 2,4 2.3 X 2(a)) 2 920N 500 2.50 4.37 5.13 5.13 3.79 9.13 3.88 6.0 5.6 - X 50 3450 63,5 111 130 130 96 232 99 2.7 2.5 X 21/2 (a) 5 920 500 2.75 4.19 5.13 5.13 3.69 9.38 4.63 8.3 7.6 9 65 3450 69.9 1 105 130 130 94 238 118 3,8 3,4 1 X 76. mm (a)(b, 920 500 2.75 - - 5.21 3.69 9.38 5.38 - 8.4 3450 69.9 - 132 94 238 1 137 1 - 3,8 X 3(a) 5 920 500 3.50 4.50 5.50 5.13 3.69 9.38 5.38 9.9 8.4 X 80 3450 88.9 114 140 130 94 238 137 4,5 3,8 X 4(a) 5 2 920 500 4.50 4.50 5.75 5.38 3.69 9.38 6.25 10.1 10.1 X 100 3450 114,3 114 146 137 94 238 159 4.6 4,6 159.0 mm X 11/2 (a) 920N 500 2.00 4.41 5.13 - 3.63 9.25 3.38 78 - X 40 3450 50,8 112 130 - 92 235 86 3,5 - X 2(a) 920N 500 2.50 4.37 5.13 - 3.63 9.25 4.00 8.0 -. X 50 3450 63,5 111 130 - 92 235 102 3,6 - X 292 (a) 920 500 2.75 4.56 5.50 - 3.63 9.25 4.75 8.6 - X 65 3450 69,9 116 140 - 92 235 121 3,9 - 1080 mm 920 500 4.50 - - 5.38 3.63 9.25 6.25 10.0 3450 114.3 - - 137 92 235 159 - 4,5 165,1 mm X 11/2 (a) 5 2 920 500 2.00 4.44 5.13 5.13 3.69 9.38 3.75 79 6.9 7 3450 58 113 130 130 94 238 95 3.6 3.1 X 2(a) 1 920 500 2.50 4.44 5.13 5.13 3.63 9.38 4.38 8.0 7.0 X 50 3450 63,5 113 130 130 92 238 111 3,6 3.2 X 295 920 500 2.75 4.19 5.13 5.13 3.69 9.38 4.63 8.6 7.6 5 65 3450 69.9 106 130 130 94 238 118 3,9 3,4 X 76,1 mm (a) (b) 920 500 2.75 4.08 5.13 5.21 3.69 9.38 5.38 8.6 7.6 3450 69,9 104 130 132 94 238 137 3,9 3,4 X 3(a) 5 92 0 500 3.50 4.50 5.50 5.13 3.69 9.38 5.38 10.2 8.4 7 80 3450 88,9 114 140 130 94 238 137 4.6 3,8 X 4(a) 1 920 500 4.50 4.50 5.75 5.38 3.63 9.38 6.25 10.5 8.4 X 100 3450 114.3 114 146 137 92 1 238 159 4,8 3,8 8 X 2(a) 920 500 2.75 5.19 6.25 - 4.88 12.00 450 11.6 - 200 X 50 3450 69,9 132 159 - 124 305 114 5,3 X 21/2 (a) 5 920 500 2.75 5.19 6.25 6.25 4.88 12.25 4.50 11.6 11.6 X 65 3450 69.9 132 159 159 124 311 114 5,3 5,3 X 761 mm (a) (b) 920 500 2.75 5.19 6.25 - 4.88 1200 5.38 - -, 3450 69 132 159 - 124 305 137 - - X 3(a) 5 920 500 3.50 5.50 6.50 6.25 4.88 12.00 5.38 12.6 11.6 X 80 3450 88,9 140 165 159 124 305 137 5,7 5,3 X 4(a) t 920 500 .4.50 5.31 6.75 6.38 4.88 12.00 6.25 15.3 12.5 5 100 3450 114,3 135 171 162 124 305 159 69 57 see notes at ion DIMENSIONS Y-- Z Styles 920 and 920N w/Grooved Outlet NOTE: Style 920 and Style 920N housings cannot be mated to achieve cross connections. These new size Style NEW 920N products require a HOLE SIZE different hole size than the Style 920 it replaces, for proper installation. Use caution to assure the proper size hole is prepared for the specific size and style used Failure to use the proper hole size could result in Joint leakage and property damage NOTES "Center of run to engaged pipe end, female threaded outlet only (Dimen-sions approximate) Available with grooved or female threaded outlet. Specify choice on ordcr Center of run to end of fitting. 4 Female threaded outlets are avail- able to NPT and BSPT Specifications. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. )h( For 76,1 mm threaded outlet, spec- ify 2112." BSPT clearly on Order. Styles 920 and 920N Mechanical-I® Bolted Branch Outlets 11.02 Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 900N and 929 Mechanical.T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. OUTLET SIZE Equivalent Length Feet/meter of Pipe Nominal Actual Diameter Out. Dia. Female lnJmm In/mm Grooved Threaded 1/2 0.840 - 2.0 15 21,3 - 0,6 3/4 1.050 - 4.0 20 26,7 - 1,2 1 1.315 - 5.0 25 33,7 - 1,5 11/4 1.660 5.5 6.0 32 42,4 1,7 1,8 11/2 1.900 7.0 8.0 40 48.3 2,1 2.4 2 2.375 9.0 10.5 50 60,3 2,7 3.2 21I2 2.875 11.0 12.5 65 73,0 3.4 3.8 3 3.500 13.5 15.5 80 88,9 4.1 4,7 4 4.500 20.0 22.0 100 1 114.3 6,1 63 FLOW DATA © 1I Exaggerated for Clarity Cv Values Values for flow of water at +60F (+16CC) are shown in the table at right. Formulas for CV Values: cf,2 Q = CX./KP Where: Q = Flow (GPM) AP = Pressure Drop (PSI) Cv = Flow Coefficient Pipe Size Pipe Size Pipe Size Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside Diameter Diameter Cv Diameter Diameter Cv Diameter Diameter Cv Inches/mm Inches/mm Values Inches/mm Inches/mm Values Inches/mm Inches/mm Values 1/2 0.840 17 11/4 1 .660 45 2'/u 2.875 15 21.3 32 42.4 65 73,0 135 3/4 1.050 21 11/2 1.900 60 3 3.500 20 26,7 40 48,3 80 88.9 1 200 1 1.315 25 2 2.375 100 4 4.500 25 33,7 50 60,3 100 114,3 400 APPROVED PRESSURE RATINGS The Information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated Working Pressures Run Size PSIlkPa Actual Nominal Outside Diameter Diameter Pipe Inches/mm Inches/mm Schedule UL ULC FM 2112 - 6 2.875 - 6.625 1 40 400 400 400 65 150 13,0-168.3 2755 2755 2755 21/2.4 2.875 - 4.500 DF 300 300 300 65100 1 73.0- 114,3 1 2065 1 2065 1 2065 2'/2-4 2.875-4.500 300 300 300 65-100 73.0- 114.3 SF 2065 2065 2065 r4U I t: IL) rorors 10 eisteci//\pproveo 5cilediilo 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 Steel sprinkler pipe OF rulers to Listed/Approved Dyna.Flow steel sprinkler pipe manufactured by American Tube Cornparry. SF refers to Listed/Approved Super-Flo steel Sprinkler pipe manufactured by Allied Tube and conduit corporation. This product shall be marrulacturod by Victaulic Company. All products to he installed in accordance with current Victaulic installation/assembly instructions ViCtaulic reserves the right to change product Specifications, designs and standard equipment without notice and without incurring obligations. Styles 920 and 920N Mechanical-TI Bolted Branch Outlets Component of State of California OSHPD Approved Seismic Restraints System .- FIG. 98 Size Range - Secures 3/8 thru 7/8 rod in 1 increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8 thru 7/8 hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved w the State of California Office of Statewide Health Plannina and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number ' " FIG. 98B --' Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Length Size Range - Secures 3/8 thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F WtJ100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICEJMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wti100 3/8 1/ie 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 65 Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1Ae 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 1114 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Component of State of California OSHPD Approved c nQL US LISTED Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8, 1/2 and 5/8° rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4 (Fig. 65) or 11/4 (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8° rod will support 1/2 thru 4° pipe, 1/2° rod will support 1/2° thru 8° pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH 951.737.5599 • FAX: 951.737.0330 I CUSTOMER SERVICE • 800.786.5266 www.toIco.com Fig. 2 - Adjustable Band Hanger Size Range - Size 21/2 thru 6 pipe. Material - Carbon Steel, Pre-Galvanized Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals - Factory Mutual Engineering approved. Underwriters Laboratories Listed, Conforms to Federal Specification WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish - Pre-Galvanized Note - Available in Stainless Steel materials. Order By - Figure number, pipe size and material C®US LISTED Dimensions • Weights Pipe Max. Rec. Approx. Size Rod Size A B C Load Lbs. Wt./100 21/2 1/2* 53/4 41/4 1/8 600 41 3 1/2* 6 41/8 11/4 600 45 31/2 1/2* 73/8 51/4 21/8 600 52 4 5/8k 7 /8 5 15/8 1000 59 5 5/8** 9 61/8 21/4 1250 97 6 3/4** 9/8 61/2 1/8 1250 139 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 9517375599 • FAX: 951.7370330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Component of State of California OSHPD Approved c &us usrro Seismic Restraints System Size Range - 3/8 and 1/2 rod; 4 thru 16 length. Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1. Features - Beveled locking slot" is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in section "A-A" or inverted. Allows easy installation for new construc- tion or retrofit applications. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore, a locking mechanism of some kind, such as the beveled locking slot of the Fig. 69R or a hex nut tightened against other types of retaining straps will provide a more secure and reliable instal- lation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, rod or set screw size and length Note - Minimum return on Strap: 1. - * Patent #5,947,424 \ A - A / Dimensions Rod Size A Length 3/8 Specify 1/2 Specify OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 9517375599 • FAX: 951.7370330 CUSTOMER SERVICE • 800.786.5266 www.folco.com r1 Fig. 25 - Surge Restrainer Size Range - One size fits 3/4 thru 2 pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed ç,n!y when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4' thru 2'. Patent #5,344,108 C®US LISTED P {i I: I i II I! .4 ill \ (I! I , I: /' .. t OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I CUSTOMER SERVICE • 800.786.5266 www.tolco.com