Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2525 EL CAMINO REAL; ; FA060004; Permit
12/5/24,10:21 AM FA060004 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA060004 2525 EL CAM INO Job Address: Status: ISSUED REAL Permit Type: FALARM Applied 3/3/2006 Parcel No: 1563020900 Approved: 3/9/2006 Lot #: 0 Reference No.: Issued: 3/9/2006 PC #: Inspector: Project Title: GNC FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: SIMPLEX GRINNELL 9855 CARROLL CANYON RD SAN DIEGO CA 858-740-0100 Owner: PLAZA CAM INO REAL C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 115 0 115 0 about:blank Ill tqco IF/re & /SimplexGrinnell / Fire / SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tale: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM PRODUCT SUBMITTAL PROJECT: GNC Plaza Camino Real 2525 El Camino 109 Carlsbad, CA 92008 114 3/3/2006 tqco /Fire & / SimplexGrinnell Security SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE DETECTION AND ALARM SYSTEM ITEM QTY MODEL NO. A 1 4006-9101 2 2081-9272 B 8 4098-9788 8 4098-9601 C 1 4098-9686 D 3 4906-9127 1 4906-9101 DESCRIPTION C.S.F.M. NO. Fire Alarm Control Panel 7165-0026:318 6.2 AH Battery N/A 2 Wire Base with LED 7300-0026:222 Photoelectric Smoke Detector 7272-0026:219 4-Wire Duct Detector 3240-0026:241 Horn/Strobe Multi-Candela 7125-0026:317 Strobe Only Multi-Candela 7125-0026:316 3/3/2006 REV.#: 0 PROJECT #: 5Simplex UL, ULC Listed; FM, CSFM, and MEA (NYC) Approved* Ik.ii3 Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient panel status information Operation is programmable using a multi-function keypad and the panel LCD or via service computer (PC) RS-232 service port provides upload/download PC access for panel configuration and event history logs Software updates are via PC download Convenient library of standard custom label terms Standard on-board DACT provides: Contact ID, 3/1, 4/2, BFSK, and SIA formats WALKTESTIM silent or audible system test** Voltage and current for both the battery charger and the battery can be displayed at the front panel LCD Five Standard Initiating Device Circuits (IDCs): Five Class B IDCs with optional expansion to ten, all with individual zone disable Monitor 2-wire or 4-wire initiating devices including TrueAlarm® smoke detectors Optional Class A Adapter Module Two Standard Notification Appliance Circuits (NACs): Class A or Class B outputs with solid state overcurrent protection per NAC, each rated for 2 A Selectable for Simplex® SmartSyncTM two-wire horn/strobe control or synchronized strobe controlt Standard Power Supply: Provides 3 A maximum @ nominal 24 DC Automatic input power selection operates with 120 VAC or 240 VAC, 50 or 60 Hz On-board temperature compensated battery charger for up to 12.7 Ali batteries in cabinet (UL and ULC) and up to 25 Ah batteries in separate cabinet (UL only) Additional standard features: Two auxiliary relays IDCs, NACs, and Relay outputs are power limited per NFPA 72® (AC input, battery circuits, and City Circuit Module outputs are non-power limited) UL listed to Standard UL 864, 9th Edition Available option modules: Door mounted 24 LED annunciator (standard on ULC models) 3 A Expansion Power Supply with two on-board 2 A NACs that operate the same as standard NACs LifeAlarm® Fire Alarm Control Panels 4006 Series Fire Alarm Control Panels Providing up to Ten lDCs and Four NACs 4006-9101 Standard Control Panel 4006-9121 Control Panel with 24 LED Annunciator Available option modules (Continued): Expansion DC module with five Class B IDCs Class A DC Adapter Module, City Interface Module, and Auxiliary Relay Module Remote LCD and LED/Switch Annunciators Dscrintic For areas requiring from five to ten initiating zones, the Simplex 4006 Series fire alarm control panels provide flexible initiating circuit monitoring, extensive programmable control capability, and LCD annunciated circuit-specific 20 character custom labels. * See page 2 for additional ULC and MEA information. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:318 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** WALKTEST system test is protected under US Patent No. 4,725,818. t SmurtSync horn/strobe opea1i0n is protected under U.S. Patent No. 6,281,789. Two-wire synchronization circuit operation is protected by U.S. patent No, 5,559,492. S4'306-0001-3 7/2005 MflITflT.I TlIIfll Five Class B lDCs are each capable of supporting up to 30 Simplex current-limited smoke detectors or electronic heat detectors (see list on page 4) as well as manual stations and other compatible contact closure initiating devices. IDCs are capable of Class A operation with an optional adapter module and can be programmed as Style C (short or open initiates a trouble) for use with current limited devices only. Two, 2 A On-Board NACs provide conventional reverse polarity operation, selectable as Class A or Class B, with electronic control and overcurrent protection. Operation is selectable for synchronized strobe or SmartSyncTM horn/strobe two-wire operation. Horn control can be selected at the panel for: Temporal pattern coding, Steady On, Slow March Time (20 beats per minute), or Fast March Time (120 beats per minute). Note: When selected for SmartSync horn/strobe control, March Time produces 60 beats per minute. The 24 VDC Auxiliary output provides up to 500 mA for system use. (Auxiliary output current is counted for total power supply capacity.) Standard Auxiliary Relay Outputs. Two relay outputs are available, selectable as normally open or normally closed, rated 2 A @ 30 VDC per below: Aux Relay 1 is normally assigned to General Alarm operation but is programmable (see page 7) Aux Relay 2 (Trouble) is energized when Normal and is de-energized with a Trouble condition. W mown NO MI Power Supply and Battery Charger. DC power output is 3 A @ 24 VDC for panel use. The temperature compensated battery charger (sealed lead-acid batteries only) is rated for up to 25 Ah batteries per UL 864 and up to 12.7 Ah per ULC-S527. (Up to 12.7 Ah batteries fit in the cabinet, larger batteries require an external cabinet.) Panel electronics can measure and display voltage and current for the power supply, batteries and the battery charger (standard and expansion power supply). Depleted battery trouble is monitored and annunciated and depleted battery cutout can be selected. Active battery status monitor supervises charger operation. Expansion Power Supply. Provides 3 A total @ 24 VDC, two additional 2 A NACs, and an additional auxiliary power output of 500 mA. Output operation is the same as on the standard power supply. Expansion IDC Module. Provides 5 additional Class B IDCs with operation the same as the standard IDCs. Expansion Relay Module. Provides 10 programmable relays, jumper selectable as N.O. or N.C. Contacts are rated 2 A @ 30 VDC. Typical application is to track status of each DC. See page 7 for relay program options. Class A Adapter Module. Converts 5 IDCs from Class B to Class A operation. Two modules can be mounted for use with the Expansion DC Module. City Circuit Modules. These modules are available On-Board Dual Line DACT. Operation can be selected with or without on-board disconnect switches, depending for Contact ID, SIA, 3/1, 4/2, and BFSK formats. on local requirements (either type can be disconnected Reporting includes Alarm, Supervisory, Trouble, and AC through the front panel under password control). Failure. Operation includes automatic 24 hour test and Connections are for Remote Station (reverse polarity) or programmable power fail report delay. Municipal Master (local energy). Reporting includes Alarm, Supervisory, and Trouble. II;t1t;11 Control Panel o e scription Listings Box Depth Standard Features 4006-9101 andard fire alarm control panel MEA 4-1/4" Red cabinet; 5 Class B IDCs, 2 Class B/Class A _________ UL, FM, (1 08 mm) NACs, 3 A power supply with battery charger; 121 ire alarm control panel with & CSFM 4-5/8" on-board DACT; for input voltage of 40 069121 24 LED Annunciator on front door ULC (1 17 mm) 120/240 VAC, 50/60 Hz (autoselect) Option Modules H Model Description 4006-9801 Expansion Power Supply; 3 A, with 2 NACs, 120/240 VAC, 50/60 Hz 4006-9802 Expansion IDC Module; 5 Class B IDCs 4006-9803 Expansion Relay Module; 10 relays selectable as either N.O. or N. C. 4006-9804 Class A Adapter Module; converts 5 IDCs from Class B to Class A 4006-9805 City Circuit Module with disconnect switch 4006-9806 1 City Circuit Module without disconnect switch Select up to one of each as required Select up to two maximum Select one if required Accessories Model Description: .. -. 2975-9812 Red semi-flush trim kit; 1-7/16" (37 mm) wide; includes four corners and trim pieces for top, bottom, and sides 4009 9801 Beige External Battery Cabinet for up to 25 Ah batteries; mounts close-nippled to control panel cabinet; dimensions - = 16-1/4" W x 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) [depth increased for 25 Ah effective 7/2005] Batteries, 12 Volt (select one battery model per system standby requirements; order quantity of two) N_'U6de_P_YJ Size "_J__-Model Size Location Model I Size Location 09276.2Ah 2081-9288 12.7 Ah For cabinet mount ll 2081-9275 18 Ah Requires 4009-9801 External Battery 2081-9827 25 Ah I Cabinet (UL listed only) 2 S4006-0001-3 7/2005 TROUBLE ACK acknowledges system troubles, logs the acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the active Trouble list SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the active Supervisory list FIVE NAVIGATION KEYS: MENU selects the on-screen programming menu; left and right arrows moves the position on the screen, and PREVIOUS and NEXT navigate screen selections ALARM SILENCE causes audible notification appliances to be silenced, used after evacuation is complete and while alarm source is being investigated FOUR EXTENDED FUNCTION KEYS: ENTER confirms selections, EXIT/CLEAR backs out of the present screen menu and clears information that has not been entered, FUNCTION enables the active function menu, DISABLE/ENABLE toggles the function or circuit status as appropriate per the selected screen Keyboard Reference FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on until reset 2 X 20 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 20 characters for custom label information FIRST ALARM DISPLAY: Operation can be selected for maintained display of first alarm until acknowledged SYSTEM NORMAL 12: 35: 15 PM 06/03/05 CONTROL ANELE1' with door closed - ALARM ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the active Alarm list THREE PROGRAMMABLE LEDs provide custom labeling (labels insert into a pocket), the top two LEDs are selectable as red or yellow, the bottom LED is selectable as green or yellow SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal - LPHANUMERIC EYPAD provides 4rorammn entry of] Door LED Annunciator Details IDC1 M IDC5 - IDC9 I IDC2 - IDC6 IDC1O N I IDC3 IDC7 IN &rr J IDC4 4 IDC8 ME 14 CUSTOM LABEL AREAS are available, typically for IDC and NAC annunciation (shown labeled for reference, blank IFOUR YELLOW LEDs provide labels are provided); dual LED locations have a Red LED default NAC Trouble annunciation (top) and a Yellow LED (bottom); labels insert into pockets ((shown labeled as NAC 1-4) behind the oveday; LED operation is programmable to track other monitored status conditions S4006-0001-3 7/2005 U Ili.i ii I. ir 1riiwurTm Ii.PowerRatings• - - - Input Voltage 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select AC Input Ratings Input Current, Standard 2 A maximum @ 120 VAC input; 1.5 A maximum @240 VAC input Input Current with Expansion Power Supply 4 A maximum @ 120 VAC input; 3 A maximum @ 240 VAC input Power Supply Output Rating 3 A maximum @ 24 VDC in alarm (see NAC details on page 6) BatteryCharger Temperature compensated charger is rated for up to 25 Ah per UL 864; up to g 12.7 Ah per ULC-S527 Standby Current 130 mA; with 5 lDCs fully loaded, tone-alert silenced, trouble LED on Standard Circuit Ratings (NOTE: TotalDC current = 3 A maximum) Notification Appliance Circuits (NACs) NOTE: See details on page 6 2 A maximum @ 24 VDC, per circuit; available as Class A or Class B; Class B end-of-line resistor = 10 kQ, 1/2W; Model 4081-9008 (PIN 733-894) Supervisory Current 3 mA maximum Initiating Device Alarm Current 60 mA maximum Circuits (lDCs) Capacity End-of-Line Resistor Each IDC supports up to 30 detectors (smoke or electronic heat) and manual stations as required; wiring distance is limited to 50 D maximum 3.3 kQ, 1/2 W; Model 4081-9002 (P/N 733-893) for Class B IDCs Quantity Supported Up to four annunciator modules per panel (see page 5 for details) Wiring Type Twisted pair, or twisted, shielded pair; 18 AWG (0.82 mm2) Bus-Style Wiring Up to 4000 ft (1219 m); 0.58 iiF (580 nF) maximum capacitance; 35 n max. Annunciator "I T-Tap" Wiring Communications Line Matching Resistor Up to 10,000 ft (3048 m) total wiring; up to 2500 ft (762 m) to farthest device Bus-style, connect one at panel 100 Q, 1/2 W; 4081-9011; T-Tap, connect one at panel and one at end of line (part number 733-974) Suppression Use 2081-9044 Overvoltage Protectors where wiring leaves and enters a building (refer to data sheet S2081-0016) Auxiliary Power Output 500 mA maximum @ 24 VDC Standard Auxiliary Relay Outputs Relay 1 Relay 2 Programmable operation Contacts rated 2 A @ 30 VDC, 0.35 power factor; jumper selectable as N.O. or N.C. Trouble operation Wiring Connections for Above Circuits and AC Input Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Option Module Ratings Class A IDC Adapter Module Five circuits per module, rated same as circuits Ten Relay Auxiliary Contact Ratings 2 A @ 30 VDC, 0.35 power factor; jumper selectable as N.O. or N.C. Module 4006-9803 Wiring Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) Environmental Ratings - Operating Temperature Range 32° to 120°F (0° to 49° C) ODeratina Humidity Ranae UD to 93% RH. non-condensina 0 100.4° F (38° C) maximum Reference Information, Compatible Simplex Peripherals ICompatible Simplex 1IDetectors Model Type - Description Data Sheet 4098-9601 for 2-wire and 4-wire bases Photoelectric smoke detectors Standard detector (2.8% nominal) S4098-0015 4098-9605 Reduced sensitivity detector (3.5% nominal) 4098-9602 Combination smoke and heat detector S4098-0017 4098 Series Duct detector housings 2-wire and 4-wire models S4098-0029 4098 Series Ionization Smoke Detectors 2-wire and 4-wire models S4098-0018 4098-9612 Electronic heat detectors for 2-wire and 4-wire bases 135° F (57°C) Fixed temperature heat detector S4098-0014 4098-9614 200° F (93°C) 4098-9613 135° F (57°C) Fixed temperature heat detector with rate-of-rise detection 4098-9615 200° F (93°C) Compatible System Expansion Panels Model Type Description - - Data Sheet 4003 Series Voice Control Panel Pro ides remote voice control p:n:I with on-board NACs, internal S4003-0001 - microphone, and remote microphone input 4009 Series Remote NAC Extender Provides remote NACs; includes power supply and battery charger S4009-0002 4 extenders max/NAC; 4006 uses NAC output to provide control Note: Contact your local Simplex Product Supplier for additional compatible peripherals. 4 S4006-0001-3 7/2005 MTI I I•- Alarm 4006-9101 Standard fire alarm control panel Suory 130 mA 160 mA ___________ _____________________________________ +60 mA per IDC in Alarm 4006-9121 Control panel with 24 LED Annunciator + 6 mA per in larm 4006-9801 Expansion Power Supply 50 mA 60 mA 4006-9802 Expansion IDC Module 50 mA 50 mA + 60 mA per IDC in Alarm 4006-9803 Expansion Relay Module 0 m 10 mA per energized relay 0 m + + 10 mA per energized relay 4006-9804 Five Circuit IDC Class A Adapter 0 mA normal; 0 mA normal; 10 mA per IDC in trouble 10 mA per IDC in trouble 4006-9805 City Circuit Module with disconnect switch 30 mA 60 mA 4006-9806 City Circuit Module without disconnect switch 30 mA 60 mA 4606-9101 Remote LCD Annunciator (see data sheet 100 mA 150 mA S4606-0001) 4610-9111 Remote LED/Switch Annunciator (see data 40 mA 70 mA sheet S4610-0001) (all LEDs and tone-alert on) Current Calculation Information: To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. Remote Annunciator Options The 4006 supports up to four annunciator options including: Door Mounted 24 LED Annunciator 4610-9111 Remote LED/Switch Annunciators 4606-9101 Remote LCD Annunciators Annunciators communicate at a rate of 9600 baud with 24 VDC power supplied by separate wiring. 4610-9111 LED Annunciator Features: 4606-9101 LCD Annunciator Features: LCD readout with two lines of 40 characters each and LED backlighting Wide viewing angle, super-twist design Keyswitch access controlled Control switches and status LEDs for: Alarm, supervisory, or trouble acknowledge Alarm silence and System Reset 16 LEDs with programmable functions and dedicated Three programmable LED indicators: LEDs for Alarm Silenced, Lost Communications, Trouble, and Power-on • Two LEDs are selectable as red or yellow Keyswitch access controlled switches for • One LED is selectable as green or yellow Acknowledge, Alarm Silence, Reset, and Lamp Test • With provisions for custom labeling Local tone-alert SYSTEM IS NORMAL jamMojjCe4 4610-9111 LED/Switch Annunciator 4606-9101 LCD Annunciator 5 S4006-0001-3 7/2005 The following DC operation modes are selectable from either the front panel or the PC programmer Function Type Descripticn Device State IDC Status Normal = NORMAL FIRE Fire monitor zone Current Limited = FIRE Short= FIRE Open = TROUBLE WATER Waterfiow monitor zone Normal = Current Limited = Short = Open = NORMAL FIRE FIRE TROUBLE HEAT Heat detector zone DUCT Duct detector zone PULL Manual (pull) station zone SMOKE Smoke detector zone Normal = NORMAL SO Sprinkler Supervisory Current Limited = SUPERVISORY Short = SUPERVISORY Open = TROUBLE Normal = NORMAL WSO Combination waterfiow and water supervisory Current Limited = SUPERVISORY zone Short = ALARM Open = TROUBLE Normal = NORMAL SUPV Supervisory monitor Current Limited = SUPERVISORY Short = SUPERVISORY Open = TROUBLE Normal = OFF UTIL Supervised utility monitor Current Limited = ON Short= ON Open = TROUBLE Normal = NORMAL TROUBLE Trouble monitor Current Limited = TROUBLE Short = TROUBLE Open = TROUBLE Normal = NORMAL Verified fire alarm; the abnormal (current limited) Current Limited = VERIFY VSMOKE state causes the alarm verification cycle to start; a short is an immediate alarm Short = FIRE Open = TROUBLE Normal = NORMAL STYLEC Style C fire monitor Current Limited = FIRE Short = TROUBLE Open = TROUBLE Normal = NORMAL LATSUPV Latching supervisory monitor (supervisory Current Limited = SUPERVISORY latches until system is reset) Short = SUPERVISORY Open = TROUBLE DptaiIcd NAC Ritinc - NAC Ratings, Maximum per NAC Appliances - Simplex 4901 Series (horns) and the following 4906 Series Multi-Candela: strobes, Special Application: horn/strobes, and speaker/strobes (see data sheets S4906-0001, S4906-0002, & strobe synchronization is UL listed across all s49060003) 4 system NACs for these 4906 Series 4906-9101 I 4906-9103 I 4906-9127 4906-9129 I 4906-9151 I 4906-9154 appliances 4906-9102 4906-9104 4906-9128 4906-9130 4906-9153 Regulated 24VDC: 1.5A NOTE: Maximum strobe load on main power supply or expansion power supply is j All other UL Listed Notification Appliances; use associated external per power supply (2.7 A total); remainder of synchronization modules where required power supply rating is available for other loading 6 S4006-0001-3 7/2005 IFexirflTi1MYFiT1 The following relay operations are selectable from either the front panel or the PC programmer. Common Fire Alarm Operations r Function Type Relay Activates Upon Relay Deactivates Upon SRELAY General Alarm Silence RRELAY General Alarm Reset SUPV Supervisory condition Clear TRBL Trouble condition Acknowledged Special Functions Function Type UTILITY Description V Utility lDC in the same alarm group activates PRIMARY General alarm; relay is tied to Primary Elevator Recall contacts ALTERN General alarm; relay is tied to Alternate Elevator Recall contacts DRESET Relay provides 24 VDC power to 4-wire detectors; relay turns off for 5 seconds on System Reset DHOLDER Relay provides 24 VDC to larger door holder relay with separate power source; relay activates on general alarm to remove power to door holder relay and close doors Additional Programming Feature Details Function Details Custom label Up to 20 characters per point; a built-in message library provides for commonly used words for easy front u panel programming For front panel label creation convenience, the following words can be selected as part of a custom label (_designates a built-in space; typing the first letter of a word/number will select the closest word in alphabetical/numerical_sequence) Message Library North Center Flr3 Basement Floor Lobby main Boiler_RM Elevator South rear Flr _ _4 Garage Office first Classroom Entrance Storeroom East 5th Flr_5 Hallway Patient 2nd Closet - Restroom Wing West FIr_I RM_ HVAC_Room upper 3rd Corridor Room Zone Front Flr_2 Kitchen lower 4th Elect RM - Stairway Three separate logs: Alarm (100 entries), Supervisory (100 entries), and Trouble (300 entries); logs can be History logs queried separately, or as a combined log; logs can be downloaded for printing or archiving using the RS-232 service port Automatically scans system for installed option modules and configures panel programming accordingly; Autoprograrn modes are available to detect new modules only, recreate default programming and then add all modules found Alarm Groups Up to 99 alarm groups are available, any point may be in up to 3 alarm groups; this allows NAC and relay operation to be associated with IDC inputs according to local response requirements WALKTEST Allows one person to perform system testing; alarm or trouble tests are followed by automatic reset; the alarm zone is sounded out by associated audible notification or the response is silently logged into the Alarm log Manual Control Allows selection of individual relays or NACs for system testing Level 1 = Acknowledge, Silence, System Reset, View logs, View point information, and Lamp Test Passcode Protection Level 2 = All Level 1 + Set Time/Date, Point Control, Enable/Disable points (4-digit number) Level 3 = All Level 2 + Clear logs, Clear verification tallies, Custom label editing, and WALKTEST Level 4 = All Level 3 + Programming, Upload/Download; this is the Service access level 7 S4006-0001-3 7/2005 Installation and Module Placement Reference Ld Box width 15-5/8" (397 mm) Knockouts are (Top and side views are located on top shown with door installed) and sides o 0 0 0 Box depth =. 4-1/4" (108 mm) standard 4-5/8' (117 mm) w/annunciator door I I h I' 11-1/4" (286 mm) I. oc Expansion I Main board I Module Class A I Adapter (tUtitliOl !II1I1IIII 11111-Ill_I I 00 0 j 0 Modules* ZRIe n __ 111111111 • IIri [—ir-1I---1r--ir--( i ________________ Door thickness I — 5/8" (16 mm) 0 0 W 0= - 0= 13-1/2" 1 Display ,,, AssemblyJ 16 (343 mm) i (406 mm) CMain board J 11 0 LR CAC Input TerminalsD (City Module*) Power Supply* I (extends under I I IDC Expansion Module space) I I Battery Area -4 No conduit or wiring in this area - 13-1/4" (337 mm NOTE: For semi-flush mounting, cabinet * Indicates optional modules must extend 1-1/2" (38 mm) minimum from wall surface Tyco, Simplex, the Simplex logo, TrueAlarm, WALKTEST, and SmartSync are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). S.Simplex Tyco Safety Products Westminster• Westminster, MA • 01441-000 1 USA S4006-0001-3 7/2005 www.tycosafetyproducts-usa-wm.com 02005 Tvco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:318 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Models 4006-9101k, 4006-9121, 4008-9101, and 4008-9121 Commercial Fire Alarm Control Panels. Local, auxiliary, remote station, central station service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 4006-9801, 4008-9801 4006-9805, -9806 4006-9804 4006-9803, 4008-9802 4006-9802 4090-9007 Expansion Power Supply (EPS) City Circuit Modules (CCM) Class A Adaptor (CIA) Relay Modules (ARM) Expansion Initiating Device Circuit (XlUM) IDNet Signal Individual Adapter Module (Sigl) RATING: INSTALLATION: MARKING APPROVAL: 120 v, 60 Hz, 2 A In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, model number, electrical rating, and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. 12-14-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 5$implex Rechargeable, sealed lead-acid design: Lead-calcium grid structure Immobilized electrolyte in absorbent separator High reliability dual seal construction Low maintenance, no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size For applications requiring 110 Ah batteries: Refer to data sheet S4081-0002 for 4100U systems Refer to data sheet S2081-0012 for 4100/4120 series system Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the batterywiring distances are both minimized. Fire Alarm Control Panel Accessories Cabinet Mounted System Batteries; 2081 Series, Sealed Lead-Acid; 6.2 Ah to 50 Ah Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets I Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Specification Summary Nominal Voltage Rating 12 V/battery Discharge Rating 20 Hour Rate Typical Chart/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. S2081-0006-16 9/2004 Inner cover Absorbent sei used to imrr eIe Lead-calclu, C Typical Construction Details Actual appearance will vary with battery size. Cell case (high impact polystyrene) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator S2081-0006-16 9/2004 Battery Specifications Capacity @20 Hour Width* Depth* Height with Approximate L. Discharge Rate Terminals :_Weight* 2081 -9272 6.2 Ah 6-1/8" (156 mm) 2-5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 10 Ah (153 mm) 4-1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6" (153 mm) (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (66 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) (127 mm) (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 (square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9-1/2" (241 mm) 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Simplex Control Panel Model Series (see legend and notes below) ______ Capacity 4003 Model 4006& 4004 4004R 4005 4009 - _______ 4010 4100U 4100 &4120 4020 (all models) (2 or 3 bay) (2, 4 or 6-Unit) (2, 4 or 6-Unit) 2081-9272 6.2 Ah If 1 1 1 f I I I I I 2081-9274 10 Ah I I 1 1 1 1 If / 1 / 2081-9288 12.7 Ah I I I I I I I I I 2081-9275 18 Ah I Note 3 / Ext Ext Note 2 1 1 1 2081-9287 25 Ah Note 3 Ext I I I Ext 2081-9271 (rectangular) 33 Ah Note 3 Ext Note 3 / Ext Note 4 2081-9276 33 Ah Note 3 Ext Note 3 / 1 Ext ("square") 2081-9296 50 Ah Note 3 Note 3 1 Ext Ext I = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 Shaded areas = Not applicable NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. S2081-0006-16 9/2004 External Battery Cabinet Compatibility Reference Externally Mounted Battery Battery Cabinets without Chargers Battery * Capacity Cabinets with Chargers (connects to charger in panel) Model 2081-930V" 2081-9303" 4081 Series 2081-9270" 2081-9281 2081-9282 4009-9801 4009-9802 2081-9275 18 Ah If If If If If If 1 1 2081-9287 25 Ah 2081-9271 If If If If If If .". 0. (rectangular) 33 Ah 2081-9276 If I If If f If (square") 2081-9296 50 Ah If If If If * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. 1= Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specification Reference ModeI :Description i....i:..: i. Color :i. .1 Dimensions 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 2081-9281 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 20819270* External battery cabinet without charger Red 26-1/2" W x 12" H x 12" D 2081-9301" External battery cabinet with charger 2081-9302* External battery cabinet without charger and with meters for voltage and current (673 mm x 305 mm x 305 mm) 2081-9303" External battery cabinet with charger and with meters for voltage and current 4009-9801 For up to 18 Ah External battery cabinet without charger, 16-1/4" W x 13-1/2" H x 4-1/8" D batteries with solid door and battery harness, for close-nippled mounting to fire alarm control Beige (413mmx343mmx105mm) For up to 33 Ah 25-3/4" 20-3/4" H x 4-1/8" D 4009-9802 batteries panel cabinet (654 mm x 527 mm x 105 mm) 4081 For up to 50 Ah Companion cabinet with charger for the Beige or 22-1/2" W x16-3/4" H x 8-3/8" D Series** batteries 4010 and 4004R fire alarm control panel Red (572 mm x 425 mm x 213 mm) * Refer to Simplex data sheet S2081-0002 for additional information. ** Refer to Simplex data sheet S4081-0001 for additional information. Tyco, Simplex, and the Simplex logo are trademarks of Tyco international Services AG or its affiliates in the U.S. and/or other countries. -mplex Tyco Safety Products Westminster. Westminster, MA . 01441-0001 USA S20981-0006-16 9/2004 S www. tycosafetyproducts-usa-wm. com 02004 Tyco 5*/v Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. Simplex UL, ULC Listed; FM, CSFM, and MEA (NYC) Approved* I1!I(4c Photoelectric smoke detector with on-board TrueAlarm sensitivity drift compensationt UL listed to Standard 268 Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: 4098-9601, Standard Sensitivity, nominal 2.8%/ft obscuration 4098-9605, Special Application Sensitivity, nominal 3.5%/ft obscuration Available base options: Bases for 2-wire or 4-wire operation Auxiliary alarm relay output Optional remote alarm indicating LED Iii*iF1It1 Simplex® TrueAlarm photoelectric detectors provide many of the proven TrueAlarm analog sensing features for applications where detectors are connected to conventional 2-wire or 4-wire initiating device circuits (IDCs). Each TrueAlarm detector has an on-board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. TrueAlarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high performance smoke capture abilityt. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. TrueAlarm® Smoke Detectors TrueAlarm Photoelectric Smoke Detectors for Two-Wire and Four-Wire Bases 4098-9601 TrueAlarm Photoelectric Detector Mounted in Base Specifications Voltage Standby Current y 100A @24 VDC Alarm Current, 2-Wi r Up to 86 mA maximum, exact current is Operation determined by alarm current limiting of connected IDC Alarm Current, 4-Wire Operation Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/mm (0-610 m/min) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 15° to 122° F (-9° to + 50° C) Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non-condensing Color Frost White 4-718" Dia. x 1-7/8" H, mounted in base Dimensions (124 mm x 48 mm); refer to page 3 for detail * ULC listed models are designated with a C' suffix such as 4098-9601G. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7272-0026:219 for allowable values and/or conditions concerning material presented in this document, it is Subject to re- examination, revision, and possible cancellation. Accepted for use - city of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. t TrueAlarrn smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; 0392,573. S4098-0015-5 10/02 Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accumulation of dust and dirt. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. (See page 3.) !TT1tTurT1 tii Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke detector spacing of 30 ft (9.1 m) may be used as a guide. For detailed installation information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). Sensitivity Selection. The 4098-9601 standard sensitivity detector is recommended for most applications. When a special application for a reduced sensitivity detector is required, the 4098-9605 should be considered. Consult your local Simplex product supplier for assistance in determining the proper selection. Ddljct Slcrtir Smoke Detectors es~Epljtion -NorninalSiti mplity_ 4098-9601_ TrueAlarm Photoelectric Detector 2.8%/ft (standard) Compatible with bases: 4098-9788, 4098-9682, and - 3.5%/ft 4098-9683 Compatible Bases iidl. Description - Details* 4098-9788 .2-Wire Base with connections for IDC and LED connections are screw terminals for in/out wiring, çRemote Alarm LED Indicator 18 to 14 AWG -,--'--t--'.--'--t- 4-Wire Base with Auxiliary Alarm Relay Ratings, Single Form "C", For Suppressed Loads: Relay Contacts and connections for Power limited, 3 A @28 VDC; Non-power limited, 3 A @ 120 VAC 4098-9682 Remote LED Alarm Indicator Wiring Connections (In/Out where required): NOTE: Requires external 24 VDC for operation Relay contacts and IDC wiring, color coded 18 AWG leads; LED wiring, screw terminals for 18 to 14 AWG 2-Wire Base with Auxiliary Alarm Relay Ratings, Dual Form "C", For Suppressed Loads: Relay & connections for Remote LED Power limited, I A @ 28 VDC; Non-power limited, 1/2 A @ 120 VAC Indicator Wiring Connections (In/Out where required): 4098-9683 NOTE: Must be connected as the only device on the IDC to ensure relay Relay contacts and IDC (-), color coded 18 AWG leads; operation. IDC (+) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories Model Description Details Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes 4098-9832 Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098-9788, -9682, & -9683 4098-9830 Remote LED Indicator Mounted on single gang stainless steel plate 2098-9739 Encapsulated Dimensions: 2-1/2" x 1-1/2" xl" Required for 4-wire circuits using 24 VDC End-of-Line Relay (64 mm x 38 mm x 25.4 mm) 4098-9682 base, one per circuit; select mounting type as required; wiring is Mounted on single gang 2098-9735 Plate Mounted stainless steel plate color coded 18 AWG wire leads * Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm2; 14 AWG = 2.08 mm2 S4098-0015-5 10/02 Detector Status LED Indications 0 Indication Status - - - Pulses approximately every 4 seconds Normal Steady On I -- -- Alarm - LED Response to Magnetic Test * LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal sensitivity is within None compensation range LED pulses quickly, 6 times in 3 seconds, i i Alarm s initiated More sensitive, out of normal then turns ON compensation range Cleaning or other service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required * Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual 574-709 for further test and maintenance information. Dimensions and Reference Information 1/4" (6.4mm) 6-3/8" (162 mm) _ I 4098-9832 Adapter Plate 4 4-7/8" (124 mm) "I Base height 11/16" (17 mm) 1-7/8" (48mm) rII LED Status Indicator (with clear lens) 4098-9601 & -9605 Dimensions Mounted on Base ALARM 0 fisildex 4098-9830 Remote LED Indicator (not to scale) S4098-0015-5 10/02 Mounting Information (Electrical boxes are supplied by others.) Electrical Box Requirements: Without Jl (base 4098-9788): 4" octagonal or 4" square, 1-1/2" deep Single gang, 2" deep ithzlx (bases 4098-9682 and 4098-9683): 4" octagonal, 1-1/2" deep, with 1-1/2" extension ring 4" square, 1-1/2" deep, with 1-1/2" extension ring Surface mount reference square box_ 104 0 4" (102 mm) octagonal box 1-1/2" (38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4" (6.4 mm) maximum recess 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and to 4" square flush mount boxes 4098-9682 and 4098-9683 include a relay module that mounts in base electrical box Smoke Detector Bases 4098-9788, 9682, & -9683 4098-9601, -9605 Smoke Detector Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). SnripIe.x TEPG-US• 91 Technology Drive • Westminster, Massachusetts • 01441-0001 USA S4098-0015-5 10/02 © 2002 TEPG-US (a Ti'co company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING APPROVAL 7300-0026:222 Misc. Devices/Control Unit Accessories Page 1 of I ZLYSE J3A £J/LEP 1AJo1c11T0K Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 Models 4098-9682, 4098-9683, 4098-9788and 4098-9684 detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, model number, electrical rating and UL label. Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:219 Page 1 of 1 CATEGORY: Photoelectric Smoke Detectors LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Model 4098-9601, -960ITSP,-9602, -96021SP, -9605, -9605TSP; *GsA40989601 *..9602 and *..9605 photoelectric type smoke detectors. Models 4098-9602, -9602TSP; and *G5A4098..9602 employs an integral 1350F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector and not intended for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed system description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with listee's listed Models 4098-9682, - 9683 or -9788 detector bases *(CSFM Listing No. 7300-0026:222) and separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager fiSimplex TrueAlarm® Smoke Detectors UL, ULC Listed; FM, CSFM, Duct Detector Housings with TrueAlarm Photoelectric and MEA (NYC) Approved* Detector for 2-Wire or 4-Wire Operation BMW M_ Compact air duct detector housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke detectort and features: On-board TrueAlarm sensitivity drift compensation and dirt accumulation tracking Multi-function status LED indicator Magnetic test that initiates an alarm and provides detailed diagnostic information Clear cover allowing visual inspection Test ports provide functional smoke testing access with cover in place UL listed to Standard 268A Model availability: 4098-9685, 2-Wire standard operation 4098-9688, 2-Wire with supervised control for a single remote relay (relay included) 4098-9686, 4-Wire operation with supervised control for multiple remote relays (includes one remote relay) Mounts to rectangular ducts or round ducts Minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetically operated functional test: Initiates alarm and displays dirt accumulation status using the detector status LED Assists with maintenance priorities by categorizing detector status and identifying dirty detectors Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Red alarm LED (4098-9830) Test stations with LED(s) and keyswitch (refer to page 2 for compatibility) Relays for remote control applications * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. ULC listed models are designated with a "C' suffix such as 4098-9685C. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarm smoke detector operation is protected by one or more of the following US Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,552,765; 5,710,541; 0383,407; D388,352; D392,573. Duct Detector Housing, Front View ['1 [1 11 o 0 ii H H 4098-9830 4098-9834 4098-9835 Remote Alarm Indicators and Test Stations irnrrvrrnii Operation. Simplex® air duct smoke detector housings provide a TrueAlarm smoke detector for monitoring air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke detector mounted in the housing. These duct detector housings with smoke detectors are compatible with Simplex fire alarm control panels that provide conventional two-wire or four-wire initiating device circuits (IDCs). IY!u.rTl Each supports a remote red alarm LED or a remote test station with LED(s). Models with relay output provide relay coil wiring supervision that will transfer a trouble to the IDC if supervision is lost. 2-Wire Model 4098-9685 provides basic smoke detection for applications that do not require a remote relay. Power is from the IDC. 2-Wire Model 4098-9688 provides a supervised relay output for connection to a single 4098-9841 relay. This model is powered from the DC and requires connection as the only device to ensure relay operation. 4-Wire Model 4098-9686 provides a supervised relay control output that can control up to 15, PAM-SD control relays. Relay supervision troubles are indicated by a yellow LED on the interface board. (Resettable 24 VDC is required, see page 4.) Remote test station 4098-9835 is available for use with this model to provide a test keyswitch, a red LED alarm indicator and a green power-on LED. S4098-0029-4 10/2003 Duct Detector Selection Chart Duct Smoke Detector Housing with Photoelectric Detector* LL Model Description Compatibility_____________ 4098-9685 2-Wire Duct Detector, standard operation No relay(s) 2-Wire Duct Detector with supervised single remote relay output; 4098-9688 includes one 4098-9841 relay; NOTE: Must be only device on IDC for proper relay operation; (When used with the Simplex Supplied relay is required Remote LED 4004 or 4005 fire alarm control panel, connect to "high current" operation for proper op indicator and lDCs only) test stations below per -Wire Duct Detector with supervised multiple remote relay output, Up to 15 total PAM-SD 4098-9686requires =4 resettable 24 VDC fire alarm power and relay end-of-line relays (additional relays are resistor; includes one PAM-SD relay ordered separately) LED Indicator and Remote Test Stations (Select one if required) Each assembly is on a single gang stainless steel plate, wiring is 18 AWG (0.82 mm2 ) color coded wire leads Model Description Compatlbillty_ MountIng_ 4098-9830 Red LED alarm indicator 4098-9685 4098-9688 Use single gang box, 3" H x 2" W x 2" D 4098-9834 Test Station with keyswitch and red LED alarm indicator (turning switch to "TEST" initiates alarm for system testing) 4098-9686 (76mmx51 mm 4098-9835 Test Station with keyswitch, red LED alarm indicator, and green 4098-9686 only x 51 mm) power-on LED Epoxy Encapsulated Remote Relays (wiring is 18 AWG (0.82 mm2 ) color coded wire leads) LL_ Description ompatiblllty Mounting 4098-9841 Relay, dual Form C (1/2 A @ 120 VAC); 4098-9688 only, included with 4098-9688 Refer to pages 3 I and 4 for one maximum Locate relays within 3 ft (1 m) of device Relay, single Form C (10 A @ 120 VAC); order additional relay 4098-9686 only, being controlled, per PAM-SD separately from Air Products & Controls, Ltd.; information connect up to 15 NFPA 72 one included with 4098-9686 I 1 * Each duct housing includes an internally mounted model 4098-9601 TrueAlarm photoelectric detector and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Overall Duct Width - Tube Required Suggested Cut Length (305 mm) 2098-9796 1/2 in. (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2 in. (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098.9797 2 in. (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2 in. (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2 in. (51 mm) longer than duct width TrueAlarm Detector Status LED Indications --- LED Indication Status - Pulses approximately every 4 seconds Normal Steady On j Alarm Detector LED Response to Magnetic Test ** F LED Indication Followed By Status -- Action LED turns ON Alarm is initiated Normal, sensitivity is within None compensation range LED pulses quickly, More sensitive, out of normal 6 times in 3 seconds, ' Alarm is initiated compensation range Cleaning or other then turns ON service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range Does not initiate Alarm Detector is malfunctioning Service is required then turns ON Testing requires placing a magnet at the designated location on the duct housing cover for 4 seconds and referring to the response from the red LED status indicator on the detector. Refer to Installation Instructions 574-776 for further test and maintenance information. S4098-0029-4 10/2003 6 f _T— PIin9tube access hole I Ill UI NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. [Magnetic test area I Exhaust tube access hole) Conduit b others . x Metal plate with dual holes I - for 3/4(19 mm) conduit, plug supplied for unused hole 4098-9601 Smoke detector [ Yellow LED, relay control trouble mounted in base (supplied J indicator (4098-9686 only) I-Ll LI Wiring V rn rn (Captive fastening screws (41 - -- Mount as shown (preferred) or isparent cover) with electronics area located to [Gasketed detector area) the LEFT or UP ONLY 3-318 (86 mm) 13116' (21 mm) Test ports (2) provided for measuring airflow and for aerosol injection Sampling tube, ordered separately per duct width Exhaust tube (supplied) End View with Duct and Tubes Duct housing ] 118 Round duct outlin t -- (minimum diameter) 8" Square duct outlinel haust tube :-[ (minimum width) . . I hole alignment1 with holes facing into aiow (template is I Sampling tube, keyed for proper I provided for proper tube installation) I Remote Relays NOTE: Mount in separate electrical box within 3 ft 1 in) of device being controlled per NFPA 72 L1/4" ( mm), (13 mm) 2-3/8" (60 mm) [_4098-9841 (1/2 A @ 120 VAC) ] 13/16" 1-1 21 mm) (38 mm) " 1-3/16" (30 mm) [PAM-SD (10 A@ 120 VAC)] 3 S4098-0029-4 10/2003 Duct Detector Location Reference Exhaust Detector Damper OK 1 II .Return Air Do not locate detector here Return air damper Ii I Supply i-iiter '- Detector Do not locate bank OK detector here Bend or other obstruction 77 Return air 6 Duct inlet 6 Duct 9 minimum widths widths minimum Preferred Duct Detector Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standardfor the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Exhaust Fresh air Specifications Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (180 C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Black base with clear cover Two-Wire Operation, Models 4098-9685 and 4098-9688 Operating Voltage 18-32 VDC, from compatible IDC 4098-9685 (no relay) Standby Curren 100 1iA @ 24 VDC Alarm Current4AIaxiIm 2D( '\ Standby Cur(ent 2.7 mA @ 24 VDC (includes rel4 supervision 4098-9688 Alarm Currèlit 40 mA maximum @ 24 VDC ) (with single relay control) Relay Cool NOTE: Only one Relay Rating Dual Form C, I A @ 28 VDC, 1/2 A @ 120 VAC, Resistive 4098-9688 per IDC 100 ft (30 m) maximum to relay coil, relay must be within 3 ft (1 m) of device Relay Location being controlled per NFPA 72 [Four-Wire Operation, Model 4098-9686, Requires Resettable and Fused 24 VDC from Fire Alarm Power Supply Operating Voltage 18-32 VDC (24 VDC nominal) Standby Current 12 mA @ 24 VDC, 32 mA @ 24 VDC with 4098-9835 Test Station Alarm Current 45 mA @ 24 VDC, 65 mA @ 24 VDC with 4098-9835 Test Station Add 15 mA @24 VDC per PAM-SD relay Supervised Remote Relay Control For use with relay PAM-SD, quantity of 15 maximum, distance of 500 ft (152 m) maximum, requires 10 1<2, 1/2 Wend-of-line resistor - [PAM-SD Relay Output Ratings Single Form C use with Model 4098-9686 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output Relay Contacts, Resistive Ratings 7 A @28 VDC; 10 A @ 120 VAC; 250 pA @ 5 VDC Location Distance 500 ft (152 m) maximum to relay coils, relays must be within 3 ft (1 m) of device being controlled per NFPA 72 Remote Alarm LED (4098-9830, -9834, & -9835) 1.7 mA, no impact to alarm current Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). 93 Tyco Safety Products Westminster- Westminster, MA - 0144 1-0001 USA S4098-0029-4 10/2003 .Simplex www.tycosafetyproducts-usa-wm.com 02003 Tyco Safe!)' Products Westminster All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:241 Page 1 of I CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441 -*0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4098-9755, *4098..9755Tsp *4098..9755up 4098-9756, *4098..9756T5P *4098..9756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/min INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager B®Simplex UL, ULC Listed; FM Approved* TrueAlert® Multi-Candela Notification Appliances Visible Notification Appliances with Horn and Synchronized Flash; Non-Addressable, SmartSyncTM Operation Compatible 0"11111111 M_ Audible/visible (NV) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair Horn control that can be selected to be temporal coded, march time coded, or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938 Class A (Style Z) operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs Wall mount A/Vs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich output sound suitable for either coded or steady operation UL listed to Standard 464 Wall and Ceiling Mount ANs D c ri nt i r Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. rn irni During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. This product was not approved by CSFM or MEA (NYC) as of document revision date. Refer to page 2 for listing status o wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operahon is protected by U.S. patent No. 5559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6281789. S4906-0002 4/2004 Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of: the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117. 1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on-until-silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on-until-reset." Svnchronizd Strobes Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. I SmartSvnc Control Sniirr.s 4100U and 4010 Fire Alarm Control Panels (refer to data sheet S4010-0001 for details; refer to data sheet S4100-0031 for basic 4100U information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-993 8 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela A/Vs 4906-9127 )Moiiiiij" Wall Housing Color Red _"FIRE11 Le tte Dnption - White Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire control White Red 4906-9128 t I Ceiling j Red White 4906-9130 White Red Wall Mount AN Adapters Model Description Dimensions - 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 1-5/8"D 4905-9940 White surface mounted boxes depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) 1 (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) SmartSync Control Module 4905-9938 I SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details 1 (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs ModeL Description 4905-9992 Red cover with white "FIRE" lettering 5-1/8" H x SW x 1-1/2" D 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount A/V Adapter Ljode1 Descnphon Duienons 49059961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 49059927* Red Wire Guard for mounting to flush mounted electrical box (216 mmx156 mm x 76 mm) 49059928* Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 1 White I Surface Mount Adapter Box Extension, use to cover 1-1/2" deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) 4905-9916 Red * UL listed by Space Age Electronics Inc S4906-0002 4/2004 VV1Y&.1T1TE1Ir.]l1 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 VDC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (00 to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VDC 24 VDC I 33 VDC Sound Type (see Note 2) Steady Coded Steady Coded I Steady I Coded Horn Output Ratings @ 10 ft (3 m) Reverberant Chamber, 86 dBA 82 dBA UL464Test 88 dBA 84 dBA i I 90 dBA I 86 dBA Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8° H x 5"W' x 2-3/4"D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 Cd 30 Cd 75 cd 110 Cd 75 A m 116 m A Reference RMS Currents 18 VDC at other voltages 24 VDC 70 mA 101 mA 184 mA 243 mA 60 mA 84 mA Housing Dimensions (with lens) 4-3/4 L" x 6-7/8" W x 2-5/8" D (121 mm x 175 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Selling (see Note 3 below) 15 Cd 30 Cd 75 Cd 110 Cd 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 81 mA 119 mA 216 mA 283 mA 70 mA 97 mA 167 mA 217 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" selling. Under the same test conditions, coded hom output "peak" sound level readings are typically 4 dBA higher. Currents are with hom on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) 11l1111111 11 1 (Th cTh c Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others Wiring access hole a Wiring terminals for-"a ® SmartSync operation Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; factory setting is 15 Cd IMPORTANT' WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, orslightly bottom 7=ne of compatible TEle above boxes 4 NFPA 72 requires 80' (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor 1' Mounting Holes: 4° square (4) Single gang (2) Double gang (3) Strobe intensity " Removable cover viewing slot S4906-0002 4/2004 (tool required) 3 45 ______ ______ I 4905-9931 Adapter Plate 0 4905-9961 Optional Wire Guard (shown here for reference only, 4905-9931 Adapter Plate can be used on other mounting options) XI Ceiling Mount AN and Guard Installation Reference - Ceiling reference, 4" (102 mm) square box, surface mounted box /" 1-1/2"(38 mm) minimum depth j.-Ceiling reference, flush mounted bo Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are located behind the housing Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side - t!t.JJJl cilF It Il__jl- H Optional 4905-9927 Red Wire Guard ------------------------------------ Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 Cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and __~] box shown for reference 4(102mm) square 44 I I box profile, 1-1/2" (38 mm) deep Optional 4905-9961 II Wire Guard -- NV' Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco, Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSync are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). - Tyco Safety Products Westminster Westminster, MA 01441-0001 USA S4906-0002 4/2004 S Mple www.tycosafetyproducts-usa-wm.com © 2004 Tvco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument reunion date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:317 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4906-9127, 4906-9129 wall mount and Models 4906-9128 and 4906-9130 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation Instruction Manual for details. 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation V criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006) Authorized By: DIANE K. AREND, Senior Deputy Program Manager BSimplex TrueAlert® Multi-Candela Notification Appliances UL, ULC Listed, Visible Notification Appliances with Synchronized Flash; FM Approved* Non-Addressable, SmartSyncTM Operation Compatible Visible only (VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: UL listed to Standard 1971 Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: 4010 Series and 4100U Series fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control** 4009 IDNetTM NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes * This product was not approved by CSFM or MEA (NYC) as of document revision date. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6281789. Wall Mount Strobes Ceiling Mount Strobes csrintir Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. M71T1 F1TI During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Stroh Annliatinn Refcren Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S4906-0001 4/2004 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). Class B SmartSync two-wire control is available from: 4100U and 4010 Fire Alarm Control Panels; 4010 panels require operating software Revision 2.X or higher (refer to data sheet S4010-0001 for details; refer to data sheet S4100-003 1 for basic 4100U information) 4009 IDNet NAC Extender, models 4009-9201 and 4009-9301 (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938, converts separate conventional horn and strobe NAC inputs into a SmartSync NAC output; up to eight SCMs can be synchronized to each other Class A SmartSync two-wire control is available from 4100U NACs and from the 4905-9938 SCM. Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. DIlLICt SIctir, Multi-Candela Visible Notification Appliances (Strobes) _______ :Mounting Hous RRELeftenng Dch p4906-9101; 3 Red White Wall White Red Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Ceiling Red White SmartSync two-wire control compatible 4906-9104 White Red Wall Mount Strobe Adapters Description 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) Hx5-1/4" W x i-5/8"D 4905-9940 White deep surface mounted boxes Total depth with strobe =4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model— Description - -- - Disiris 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with ,, - in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, - x x 4905-9922 Class ' requires 10 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 1 4" x 4-1/8" x 1-1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description 4905-9992 1 Red cover with white "FIRE" lettering 4905-9993 1 White cover with red "FIRE" lettering Dimensions - - 5-1/8" H x SW x 1-1/2" D For Wall mount strobes (130 mm x 127 mm x 38 mm) 49059961* Wa ling mount l mount I 6-1/16" H x 6-1/16" W x 3-1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) 49059926* Ceil semi-flush or surface mounted boxes 6-1/8" x 4-3/8" x 2-7/8" deep (156mmx 111 mmx73mm) * UL listed by Space Age Electronics Inc S4906-0001 4/2004 Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 VDC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (00 to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd ' -'30 cd 75 cd' 110 cd _______________ 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 55 mA 85 mA 169 mA' 226 mA 63 mA 123 mA_,._.. ........164 mA Housing Dimensions (with lens) 4-3/4" Lx 2-5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA - Reference RMS Currents 18 VDC at other voltages r .24 VDC 64 mA 102 mA 199 mA 266 mA 4 49 mA 76 mA -- 146 mA 195 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting ( (Th çTh çTh 0 Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 71 =. =o 0 o 1-1/2" (38 mm) deep, by others LLU I ul~ wo up Wiring access hole Wiring terminals " I "I Ir• '\ Mounting Holes: 17 4" square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection 110 75 plug, accessible only [ from rear of housing; factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, orslightly Electrical above bottom box outline of compatible boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor Jr _______ S4906-0001 4/2004 Ceiling Mount Strobe Installation Reference Single gang box (Wiremold V57445) 2-1/4"(57 mm) deep, supplied by others Handy box, 1-1/2" (38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, required for 00 0( surface mount with handy box unless using the 4905-9926 wire guard mount strobe Optional 4905-9926 wire guard with mounting plate ------------------------ Strobe intensity viewing slot I In Intensity selection plug, - - - ' accessible only from rear of lens: L--housin faàtory setting is 15 cd - Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt 45 Box fltt-11--f1r11 Tr a 4 A TD 0 iI 905 9961 Optional Wire Guard 4905-993 1 Adapter Plate / (shown here for reference only, 4905-9931 Adapter Plate can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4"(102mm)square-.__J ff box profile, 1-1/2" (38 mm) deep Optional 4905-9961 Wire Guard Strobe Optional Surface Mount Adapter Skirt, 1-1/2' deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco, Simplex, the Simplex logo, IDNet, TrueAlerl, and SmartSync are trademarks of Tyco international AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). OSirriplex Tyco Safety Products Westminster• Westminster, MA - 0144 1-0001 USA S4906-0001 4/2004 www.tycosafetyproducts-usa-wm.com 0 2004 Tyco Safety Products Westminster. All rights reserved. All specifications andother information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:316 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and —9103 are for wall mount. Models 4906-9102 and —9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager SimplexGrinnell LP 9855 Carroll Canyon Road tqco /Fire & / SimplexGrinnefi San Diego, CA 92131 Tale: (858) 740-0100 / Security Fax: (858) 740-0156 www.simplexgrinnell.com APPENDIX ITEM DESCRIPTION A BUSINESS LICENSE B WARRANTY 3/3/2006 REV.#: 0 PROJECT #: tqca /Fire & ISimpIexGrinneII / Security / SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com 3/3/2006 REV.#: 0 PROJECT #: SimplexGrinnell LP 9855 Carroll Canyon Road tqca l Fre i & mp M 1e if San Diego, CA 92131 Security / Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com Contractor License # 802591 * * * Business Information * * * SIMPLEX GR1NNELL L P 6952 PRESTON AVE STE A LIVERMORE, CA 94550 Business Phone Number: (925) 273-0100 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2005 * * * License Status * * * This license is current and active. All information below should be reviewed. * * * Classifications * * * Clas Description C10 ELECTRICAL IF] FIRE PROTECTION CONTRACTOR * * * Certifications * * * Desc Rr ASBESTOS - (for bidding purposes only) * * * Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 81880913 in the amount of $10,000 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2004 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL(1): This license filed Bond of Qualifying Individual number 81880915 for RONALD GILBERT MAYLE in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 BOND OF QUALIFYING INDIVIDUAL(2): This license filed Bond of Qualifying Individual number 81880914 for FRANKLIN MICHAEL BROWN in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 * * * Workers Compensation Information * * * This license has workers compensation insurance with the AMERICAN HOME ASSURANCE COMPANY Policy Number: RMWC6610498 Effective Date: 10/01/2005 Expire Date: 10/01/2006 tL,cQ IF /re & I Security Isimplex6rinneff SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. WARRANTY SERVICE HOURS: 8:00 AM TO 5:00 PM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST.