HomeMy WebLinkAboutCT 81-16; VISTA SANTA FE; DRAINAGE STUDY; 1981-04-21VISTA SANTA FE DRAINAGE STUDY PREPARED FoR RICK ENGINEERING COMPANY APRIL 21, 1981 LEEDS, HILL AND JEWETT, INC 1275 MARKET STREET SAN FRANCISCO, CA 94103 TELEPHONE (415) 626-2070 ~□~~~D~G~~ii LEEDS, HILL AND JEWETT,INC, II. THE STUDY AREA The study area of this report is about 1,400 acres in size. About 230 acres of the study area are outside the boundaries of Vis ta Santa Fe development but contribute runoff to the development. The location and boundaries of the study area are shown on Figure 1. Existing Conditions Data on existing conditions at the study area are avaiLable from u. S. Geological Survey topographic maps and from large scale topographic maps prepared by Rick Engineering Company. Soil and ground cover data for the area are available from maps prepared by the County of San Diego. In addition to these sources of data, informa- tion obtained during field inspections of the study area and aerial photographs of existing conditions are available. Most of the 1,400 acre study area is in a natural condition, undisturbed by man's activities. The terrain of the study area is rolling hills that have moderate to steep-slopes. Natural vegetation in the area consists mainly of annual grass and open brush. Soils in the area are classified primarily as being in hydrologic soil group B that has infiltration rates of up to 0.05 inches per hour. The area is drained by two streams: Encinitas Creek that flows from east to west through the southern portion of the study area and; an unnamed stream that flows from northeast to southwest through the northern portion of the study area and joins Encinitas Creek downstream of the study area. The streams have steep slopes at their headwaters and mild slopes near the confluence of the two streams. The stream channels are fairly well incised and contain brush. The only major road that traverses Rancho Santa Fe. A minor portion of the study the area, study area is located on the west side of Rancho Santa Fe road about one mile north of Olivenhain Road, is currently developed in residential use. 4 TABLE 2 HYDROLOGIC CHARACTERISTICS FOR EXISTING CONDITIONS Mean Lag 2/ Percent Area Slope Rou.9.hness Time Area Subarea (acres) (ft/mi.) n 1./ (minutes) Developed I 914 125 . 07 58 0 II 406 235 .08 34 0 III 61.2 35 .08 38 0 1/ Mean Manning's Roughness Coefficient. 2/ Time between the beginning of excess rainfall and the centroid of runoff. scs Curve No . 80 83 84 Subarea I II III II & III I, II & III TABLE 3 PEAK DISCHARGE RATES AND RUNOFF VOLUMES AT SUBAREA OUTLETS FOR EXISTING CONDITIONS 10-Year Storm 25-Year Storm Peak Rate Volume Peak Rate Volume (cfs} (acre-feet) (cfs} (acre-feet} 78 23.6 143 39.9 59 13.6 107 21.8 10 2.2 17 3.6 68 15.8 122 25.4 136 39.4 246 65.3 TABLE 4 HYDROLOGIC CHARACTERISTICS FOR FUTURE LAND.USE CONDITIONS Mean Lag ·Percent scs Area Slope Rou.9.hness Time ?:_I Area Curve Subarea (acres) (ft/mi.) n .Y (minutes) Developed No. 1 20.6 265 .030 8.1 100 88 2 54.8 685 .030 9.1 100 89 3 40.7 690 .080 6.3 0 84 4 18.2 1530 .130 7.3 0 84 5 56.7 90 .090 21.8 0 84 6 17.6 145 .040 6.8 100 90 7 17.2 210 .045 6.9 100 89 8 12.3 510 .070 6.2 0 84 9 107.1 165 .030 9.1 100 89 10 41.5 320 .080 8.3 0 84 11 23.8 560 .080 5.6 0 84 12 86.5 215 .100 7.7 0 85 13 24.1 105 .045 3.6 100 89 14 35.7 435 .055 6.5 100 89 15 9.0 200 .050 3.6 100 89 16 34.8 225 .040 5.5 100 90 17 33.3 165 .100 16.7 0 84 18 7.9 390 .100 4.2 0 84 19 27.0 250 .040 5.8 100 90 20 47.0 355 .050 7.2 100 89 21 27.2 780 .045 7.0 100 89 22 32.3 542 .035 7.6 100 90 23 45.8 115 .050 10.5 0 83 24 18.2 120 .040 6.1 100 89 25 7.6 250 .075 5.1 100 89 26 15.3 135 .045 6.7 100 88 27 35.7 120 .035 6.6 100 89 28 29.8 105 .035 6.5 100 89 29 14.3 75 .070 11.1 0 80 30 5.7 105 .015 3.3 100 91 31 29.7 420 .040 7.2 100 89 32 50.6 240 .035 8.9 100 89 33 190.4 415 .060 17.4 0 84 34 51.7 110 .040 8.4 100 89 35 89.4 llO .120 28.4 100 82 36 8.6 200 .060 6.4 100 89 37 57.0 325 .045 10.8 100 88 38 14.5 405 .130 6.5 0 83 39 21.2 240 .055 5.5 100 -89 1/ Manning's mean roughness coefficient. ~/ Time between the beginning of excess rainfall and the centroil of runoff. TABLE 5 PEAK DISCHARGE RATES AND RUNOFF VOLUMES AT SUBAREA OUTLETS FOR FUTURE LAND USE CONDITIONS WITHOUT DRAINAGE CONTROLS 10-Year Storm 25-Year Storm Peak Rate Volume Peak Rate Volume Subarea (cfs) (acre-feet) (cfs) (acre-feet) 1 10 1.1 16 1. 6 2 28 3.1 45 4.6 3 12 1.5 21 2.3 4 5 0.6 9 1.0 5 11 2.1 20 3,3 6 13 1.2 19 1. 7 7 9 LO 14 1.3 8 3 0.4 6 0.6 9 53 5.7 84 8,3 10 11 1.4 19 2.2 11 7 0.8 12 1.3 12 17 3.3 31 5.2 13 14 1.4 22 2.1 14 21 2.0 33 3.0 15 5 0.5 9 0.7 16 24 2.1 37 3.1 17 7 1.1 13 1.8 18 2 0.3 4 0.4 19 17 1. 6 26 2,2 20 26 2.7 42 3.9 21 16 1.6 25 2.3 22 22 2.1 33 3.0 23 11 1.5 20 2.5 24 11 1.0 17 1.5 25 5 0.5 7 0.6 26 8 0.8 13 1.2 27 21 2.0 33 3.0 28 17 1.7 28 2.5 29 2 0.3 4 0.5 30 5 0.5 8 0.6 31 17 1.7 26 2,5 32 27 2.9 43 4.2 A 320 50.6 536 75.4 33 42 6.9 76 11.0 34 30 3.1 47 4,5 35 12 2.7 23 4.5 36 5 0,5 8 0,7 37 26 3,0 42 4.5 38 4 0.5 7 0.8 39 13 1.2 20 1.8 B 101 18.0 172 27.8 A+ B 420 68.6 706 103.1 TABLE 6 RUNOFF CHARACTERISTICS WITH THE DRAINAGE CONTROL PLAN 10-Year Storm 25-Year Storm 100-Year Storm Peak Outflow Peak Outflow Maximum Water Storage Characteristics cfs cfs Water Existing Future Future Existing Future Future Water Surface Land Without With Land Without With Depth Freeboard Storage Area Location Use Basins Basins Use Basins Basins (feet) (feet) ( acre-feet) (acres) A 78 320 78 143 536 150 12.2 0.6 52 8.5 B 68 101 47 122 172 79 10.3 1.9 15 4.2 A & B 136 420 124 246 706 221