Loading...
HomeMy WebLinkAboutDWG 550-1; PUD 2024-0002; CHERRY BEACH HOMES; 01-03SITEACA C I A A V E JUN I P E R A V E G A R F I E L D S T HEM L O C K A V E RED W O O D A V E TAM A R A C K A V E CHE S T N U T A V E C A R L S B A D B L V D J:\ACTIVE JOBS\4099 RINCON-CARLSBAD-CHERRY AVE\CIVIL\DRAWING\IMPROVEMENT PLANS 1 3 TYPE DESCRIPTION OWNERSHIP AGREEMENT SHEET NO.FREQUENCY MAINTENANCE MAINTENANCE STORMWATER REQUIREMENTS THAT APPLY: STANDARD STORMWATER REQUIREMENTS PRIORITY PROJECT REQUIREMENTS YES NO EXEMPT FROM YES NO EXEMPT FROM TRASH CAPTURE?HYDROMODIFICATION? TRASH CAPTURE DWG _____ HOA 3 AS NEEDEDREM TRITON TDAM 5(12) FIRM: PASCO, LARET, SUITER, AND ASSOCIATES, INC. ADDRESS: 1911 SAN DIEGO AVE, SUITE 100 CITY, STATE: SAN DIEGO, CA 92110 TELEPHONE: (858) 259-8212 BY: R.C.E. NO.: BRYAN KNAPP, PE 86542 I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. DATE: TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON: OCTOBER 27, 2023 BY: PASCO, LARET, SUITER & ASSOCIATES TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS. THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S): 204-231-05-00 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N 362 E 1665 ADDRESS: 180 CHERRY AVENUE, CARLSBAD, CA 92008 DESCRIPTION: LOCATION: RECORDED: ELEVATION:DATUM: NAME: ADDRESS: PHONE NO.: NGVD 29 1 TITLE SHEET / NOTES 2 GARFILED STREET IMPROVEMENT PLAN / DETAILS 3 CHERRY AVENUE IMPROVEMENT PLAN AND PROFILE 26.52' THE SOUTHEAST CORNER OF A VAULT ADJACENT TO THE NORTHEAST CORNER OF THE NORTHBOUND COAST HIGHWAY 101 BRIDGE OVER THE AGUA HEDIONDA LAGOON 0.1 MI SOUTH OF TAMARACK AVENUE, 38 FT EAST OF THE EDGE OF PAVEMENT BY A SINGLE PARKING SPACE FOR THE FACILITY, BASED ON POINT NUMBER 141, AS SHOWN ON CITY OF CARLSBAD CONTROL RECORD OF SURVEY 17271. BC= BOTTOM OF CURB BS= BOTTOM OF STAIR BW= BOTTOM OF WALL FS = FINISHED SURFACE FG = FINISHED GRADE FF = FINISHED FLOOR ELEVATION PER ARCHITECT FL = FLOWLINE FS = FINISHED SURFACE GF = FACE OF GARAGE ELEVATION IE = INVERT ELEVATION TC = TOP OF CURB TG = TOP OF GRATE TW = TOP OF WALL TS= TOP OF STAIR T.CAP. = TRASH CAPTURE FINAL MAP 1777 THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS, REMEDIAL GRADING, DRAINAGE FACILITIES, EROSION CONTROL FACILITIES, AND PLANTING OF PERMANENT LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIFICATIONS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. 180 CHERRY AVENUE CARLSBAD CA 92008 APN 205-231-05-00 5315 AVENIDA ENCINAS, SUITE 200 CARLSBAD, CA 92008 DWG 118-9 DWG 491-6A DWG 505-9A DWG 530-4A DWG 538-2A DWG 937-3 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS 3. THIS SET OF PLANS 4. RESOLUTION NO 7531 DATED DEC. 4, 2024 5. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) 6. SOILS REPORT AND RECOMMENDATIONS BY: GEO TEK, INC. JOB NO.: 3970-SD, DATED 03/13/2024 , WITH 2 SUPPLEMENTAL LETTERS DATED 08/06/2024 & 2/3/2025. 7. THE SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED _________ 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED________________________________ 10. STORM WATER POLLUTION PREVENTION PLAN (TIER 2) (SEE TIER 2 SWPPP DWG 550-1A) PREPARED BY: ___________, WDID NO. _____________ 11. STORM WATER QUALITY MANAGEMENT PLAN (TRASH CAPTURE) PREPARED BY: ___________ DATED: __________, REVISED: __________ 12. CALIFORNIA STORM WATER QUALITY ASSOCIATION BMP CONSTRUCTION HANDBOOK AND CALTRANS CONSTRUCTION SITE BMP MANUAL N/A 2-1/2 INCH BRASS DISK (949) 637-3254 THE LAND REFERED TO HEREIN BELOW IS SITUATED IN THE CITY OF CARLSBAD, IN THE COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: LOT E IN BLOCK 1 OF PALISADES HEIGHTS, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 1777, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JANUARY 11, 1924. (MORE FULLY DESCRIBED IN GRANT DEED RECORDED JUNE 3, 2003 AS DOCUMENT NO. 2003-0654626, IN THE OFFICE OF THE SAN DIEGO COUNTY RECORDER, O.R.) 2002 RREG INVESTMENTS SERIES, LLC SERIES IO46, A DELAWARE LIMITED LIABILITY COMPANY 4/24/2025 *AS MODIFIED BY CITY OF CARLSBAD STANDARDS ** TO BE VERIFIED BY THE R-VALUE TEST OF-WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $2,000,000.00 FOR EACH OCCURRENCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RATING OF "A-" OR BETTER AND A SIZE CATEGORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY IMPROVEMENTS ARE NOT CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT. OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND TITLE SHEET. THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF COMPLETION OF FIELD TESTS. THE SIGNED BY THE CITY ENGINEER. BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPE OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. AHEAD OF THE CONSTRUCTION TO PERMIT THE REVISIONS OF THE CONSTRUCTION PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. LEAST TWO FULL WORKING DAYS PRIOR TO STARTING CONSTRUCTION NEAR THEIR FACILITIES AND SHALL COORDINATE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERVICE ALERT (DIG ALERT) SDG&E AT&T SPECTRUM CABLE CITY OF CARLSBAD(STREETS AND STORM DRAIN) CITY OF CARLSBAD(SEWER,WATER & RECLAIMED WATER) OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER- 5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM 6. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED 7. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL THE CITY AND OTHER APPROPRIATE AGENCIES. 8. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING 9. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS 10. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO 11. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: 13. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 14. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR 15. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING BLASTING PROGRAM AND BLASTING PERMIT. 18. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 P.M. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 19. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. DURING CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 22. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES 23. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING IMPROVEMENTS SHOWN ON THIS SET OF PLANS. CERTIFICATE OF INSURANCE MUST BE FILED NAMING THE CITY OF CARLSBAD AS WRITTEN FIELD COMPACTION REPORT(S) SHALL BE IMMEDIATELY SUBMITTED TO THE CITY ENGINEERING INSPECTOR UPON COMPLETION OF THE FIELD TESTS. 12. A PRECONSTRUCTION MEETING SHALL BE HELD AT THE SITE PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK. THE CONTRACTOR SHALL SCHEDULE THE MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE (5) WORKING DAYS PRIOR TO STARTING CONSTRUCTION. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO 20. NO BLASTING SHALL BE COMMENCED WITHOUT A CITY ENGINEER APPROVED 17. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK ZONE 21. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ( ABOVEGROUND AND UNDERGROUND ) WITHIN THE PROJECT SITE SUFFICIENTLY 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A REQUIRE WRITTEN PERMISSION FROM THE DISTRICT ENGINEER. DEPUTY CITY ENGINEER AND THE UTILITY OPERATIONS' PUBLIC WORKS MANAGER. OBTAINED FROM THE C.M.W.D. OFFICE AND MUST BE SIGNED AND APPROVED BY THE CITY OF CARLSBAD'S STRUCTURES SHALL BE REMOVED PRIOR TO COMMENCEMENT OF WORK - ANY EXCEPTIONS SHALL 4. NO TREES OR STRUCTURES SHALL BE ALLOWED IN THE WATER LINE EASEMENT, ALL EXISTING TREES AND 2. BEFORE ANY CONNECTION OR SHUT DOWN OF VALVES ON EXISTING C.M.W.D. LINES, A PERMIT SHALL BE THE "CITY OF CARLSBAD ENGINEERING STANDARDS" (LATEST EDITION) VOLUMES 2 & 3. 1. WATER & RECYCLED WATER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH 6. THE EXACT HORIZONTAL AND VERTICAL ALIGNMENT AND TYPE OF MATERIALS OF THE FIRE LINE LOCATED BETWEEN THE DETECTOR CHECK VALVE AND BUILDING SHALL BE DETERMINED BY THE CITY OF CARLSBAD FIRE MARSHAL. 7. ALL POTABLE WATER SERVICES SHALL BE 1" AND ALL METERS SHALL BE 1" (UNLESS OTHERWISE NOTED ON PLANS). 5. ALL BURIED COPPER PIPING AND APPURTENANCES SHALL BE PROTECTED BY MEANS OF CATHODIC PROTECTION. IF DEVELOPER/OWNER CONDUCTS A SOILS TEST REPORT AND DEMONSTRATES THAT PROTECTION CAN BE PERFORMED IN ANOTHER MANNER, THE DISTRICT ENGINEER WILL CONSIDER AN ALTERNATIVE FORM OF PROTECTION. EXCAVATION. COX COMMUNICATIONS 8. ALL WATER METER BOXES SHALL BE 17" X 30" X 12" POLYMER CONCRETE AS MANUFACTURED BY ARMORCAST OR EQUAL (UNLESS OTHERWISE NOTED ON PLANS). 9. MINIMUM SPACING BETWEEN POTABLE WATER SERVICES AND SEWER LATERALS SHALL BE 10 FEET. 10. THE TOP OF WATER METER BOXES SHALL BE FLUSH WITH THE FINISHED SURFACE GRADE. 11. CONSTRUCTION OF WATER MAINS AND RECYCLED WATER MAINS SHALL ADHERE TO THE "CRITERIA FOR THE SEPARATION OF WATER MAINS AND SANITARY SEWERS" PUBLISHED BY THE STATE OF CALIFORNIA'S DEPARTMENT OF HEALTH SERVICES. 811 (800)411-7343 (619)237-2787 (800)227-2600 (760)434-2980 (760)438-2722 (619)262-1122 RATING GUIDE. 3. THE CONTRACTOR SHALL NOTIFY THE CITY OF CARLSBAD ENGINEERING INSPECTION DEPARTMENT 48 HOURS PRIOR TO STARTING WORK SO THAT INSPECTION MAY BE PROVIDED - TELEPHONE NO. (760)438-3891. 12. AXIAL DEFLECTION AT THE PIPE JOINTS IS NOT ALLOWED. THE USE OF A HIGH-DEFLECTION COUPLING AT A PIPE JOINT MAY BE PERMITTED BY THE INSPECTOR ON A CASE BY CASE BASIS NOT TO EXCEED 4 DEGREES TOTAL DEFLECTION PER COUPLING (2 DEGREES/EACH GASKET). USE CERTAINTEED "VINYL-IRON" H.D. FOR C900. CONSTRUCTED BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTE DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SATISFACTION 24. IN ACCORDANCE THE CITY STORM WATER STANDARDS ALL STORM DRAIN INLETS OF THE CITY ENGINEER. 13. BEFORE CONSTRUCTION BEGINS IN ANY PUBLIC RIGHT OF WAY, A CITY RIGHT OF WAY PERMIT SHALL BE REQUIRED. 14. NO CUTTING OF ASBESTOS CEMENT PIPE (ACP) IS PERMITTED. CONTRACTOR SHALL REMOVE ACP TO NEAREST COUPLING AND INSTALL ACP X PVC ADAPTORS AND THE NECESSARY PVC SIZE AND CLASS PIPE TO INSTALL THE TEE AT THE STATION. 15. PRIOR TO BACKFILL, INSTALL TRACER WIRE ON TOP OF PIPE AND SECURE IN PLACE WITH 2-INCH WIDE PLASTIC ADHESIVE TAPE AT MAXIMUM 10-FOOT INTERVALS. WIRE TO ENTER VALVE STANDS BY MEANS OF DRILLED HOLE IN PIPE STAND WALL JUST BELOW 4TTBOX. WIRE IS NOT TO INTERFERE WITH IS NOT TO INTERFERE WITH VALVE NUT OPERATION. RUN TRACER WIRE CONTINUOUSLY ALONG PIPE AND TERMINATE IN ADJACENT VALVE BOXES FOR BURIED ASSEMBLIES OR BURIED VALVES. WHERE BURIED SPLICES OCCUR, USE AN ELECTRICAL EPOXY RESIN SUCH AS SCOTCHCAST, OR APPROVED EQUAL. PROVIDE 24 INCHES OF COILED WIRE AT ACCESS POINTS FOR ATTACHMENTS OF PIPE LOCATING EQUIPMENT. EACH INSTALLED RUN OF PIPE SHALL BE CAPABLE OF BEING LOCATED USING THE TRACER WIRE. PROTECT WIRE INSULATION FROM DAMAGE DURING INSTALLATION AND BACKFILLING. WIRE INSULATION THAT IS BROKEN, CUT, OR DAMAGED SHALL BE REPLACED. TRACER WIRE SHALL BE AWG NO. 8 STRANDED COPPER WIRE WITH HIGH MOLECULAR WEIGHT POLYETHYLENE (HMW/PE) INSULATION SPECIFICALLY DESIGNED FOR DIRECT BURIAL IN CORROSIVE SOIL OR WATER. POLYETHYLENE INSULATION SHALL CONFORM TO ASTM D 1248, TYPE 1, CLASS C. WIRES WITH CUT OR DAMAGED INSULATION ARE NOT ACCEPTABLE AND REPLACEMENT OF THE ENTIRE WIRE WHICH HAS BEEN DAMAGED WILL BE REQUIRED AT THE CONTRACTOR'S EXPENSE. 1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN CONDUCTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL. THE "R" VALUE TESTS AND THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE ENGINEERING INSPECTOR FOR REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS BEFORE THE WORK BEGINS. 2. STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS, SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUILT" PLANS. NO DIRECT BURIAL STREET LIGHT FOUNDATIONS WILL BE ALL LUMINAIRES SHALL BE "CUT OFF" TYPE ALLOWED. 3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS, CROSS GUTTERS OR SURFACING OF STREETS. 4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA ADMINISTRATIVE CODE. 6. STREET TREES SHALL BE INSTALLED PER SECTION VI OF THE CITY OF CARLSBAD LANDSCAPE MANUAL. 7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN PER SDRSD DWG M19. 8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS ACT. 9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR. 10. STREET LIGHTS SHALL BE 5,500 LUMEN (40 WATT) OR 13,700 PUPIL LUMEN (100 WATT) HIGH EFFICIENCY INDUCTION LIGHTS. 1. SEWER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS (LATEST EDITION), VOLUME 1- GENERAL DESIGN STANDARDS, CHAPTER 6-DESIGN CRITERIA FOR GRAVITY SEWER LINES AND APPURTENANCES, AND VOLUME 3 - STANDARD DRAWINGS AND NOTES AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION (GREEN BOOK). 2. BEFORE ANY CONNECTION TO THE CITY'S EXISTING SYSTEM, A PERMIT SHALL BE OBTAINED FROM THE CITY. IT MUST BE SIGNED AND APPROVED BY THE CITY ENGINEER AND SUPERINTENDENT. 3. BEFORE CONSTRUCTION BEGINS IN ANY PUBLIC RIGHT OF WAY, A CITY RIGHT OF WAY PERMIT SHALL BE REQUIRED. 16. CONTRACTOR TO SUBMIT E-28 FORM TO CM+I MINIMUM 2 WEEKS PRIOR TO ANY SCHEDULED WATER SHUT DOWN BLASTING PROGRAM AND BLASTING PERMIT. 16. NO BLASTING SHALL BE COMMENCED WITHOUT A CITY ENGINEER APPROVED N/A N/A SEPT. 2024 PLSA N/A PLOT DATE: 5/27/2025 PLSA 4099 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. CHERRY BEACH HOMES BAK PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E , S U I T E 1 0 0 , S A N D I E G O , C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PUD 2024-0002 550-1 IMP. 2024-0011 N.T.S.PROPERTY BOUNDARY CENTERLINE OF ROAD ADJACENT PROPERTY LINE PUBLIC RIGHT-OF-WAY SETBACK LINE EXISTING CONTOUR LINE PROPOSED CONTOUR LINE PROPOSED DIRECTION OF FLOW PROPOSED SAWCUT OF EXISTING PAVEMENT PROPOSED 4" PCC SIDEWALK PAVEMENT PROPOSED TRENCH RESURFACING 3" ASPHALT GRIND & OVERLAY EXISTING FENCE EXISTING WATER MAIN (SIZE PER PLAN) EXISTING SEWER MAIN (SIZE PER PLAN) EXISTING GAS MAIN (SIZE PER PLAN) PROPOSED 1" DOMESTIC WATER SERVICE WITH FIRE SPRINKLER SYSTEM; 1" METER AND 1" BACKFLOW DEVICE PROPOSED 6" PRIVATE PVC SEWER MAIN WITH CLEANOUT PROPOSED 4" PRIVATE PVC SEWER LATERAL PROPOSED PCC DRIVEWAY APRON X X W W S S G G W S S S S S S S W CITY OF CARLSBAD GS-26, GS-28 CMWD W-5 CITY OF CARLSBAD S-6 SDRSD G-14D* (WIDTH PER PLAN) 3 EA EA 60 LF 390 SF 285 SF 445 LF 4,105 SF LF NAME: ADDRESS: PHONE NO.: 5315 AVENIDA ENCINAS, SUITE 200 CARLSBAD, CA 92008 (949) 637-3254 RINCON REAL ESTATE GROUP CONTACT : KEVIN DUNN CITY OF CARLSBAD S-7 PROPOSED PCC PED RAMP SDRSD G-27A 1 EA PROPOSED 3" PVC SIDEWALK SDRSD D-27 2 EA UNDERDRAIN 4" AC / 6" AB **405 SF 550-1A (WIDTH PER PLAN) PLSA 1. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL SIGNING AND STRIPING. 2. SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST VERSION), CALTRANS STANDARD SPECIFICATIONS (JULY 2006 OR LATEST VERSION THEREOF), THESE PLANS AND THE SPECIAL PROVISIONS. 3. ALL SIGNING AND STRIPING IS SUBJECT TO THE APPROVAL OF THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE, PRIOR TO INSTALLATION. 4. ANY DEVIATION FROM THESE SIGNING AND STRIPING PLANS SHALL BE APPROVED BY THE ENGINEER OF WORK AND PUBLIC WORKS DIRECTOR PRIOR TO ANY CHANGE IN THE FIELD. 5. ALL SIGNING AND STRIPING SHALL BE REFLECTIVE PER CALTRANS SPECIFICATIONS. STRIPING SHALL BE REPAINTED TWO WEEKS AFTER INITIAL PAINTING. SIGNING SHALL USE ENCAPSULATED LENS REFLECTIVE SHEETING (HIGH INTENSITY OR EQUAL). 6. PRIOR TO FINAL ACCEPTANCE OF STREET IMPROVEMENTS, ALL STREET STRIPING AND AND MARKINGS WITHIN A 500' PERIMETER OF THE CONSTRUCTION PROJECT WILL BE RESTORED TO A "LIKE NEW" CONDITION, IN A MANNER MEETING THE APPROVAL OF THE CITY INSPECTOR. 7. EXACT LOCATION OF STRIPING AND STOP LIMIT LINES SHALL BE APPROVED BY THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE PRIOR TO INSTALLATION. 8. CONTRACTOR SHALL REMOVE ALL CONFLICTING PAINTED LINES, MARKINGS AND PAVEMENT LEGENDS BY GRINDING. DEBRIS SHALL BE PROMPTLY REMOVED BY THE CONTRACTOR. 9. ALL PAVEMENT LEGENDS SHALL BE THE LATEST VERSION OFTHE CALTRANS METRIC STENCILS. 10. LIMIT LINES AND CROSSWALKS SHALL BE FIELD LOCATED. CROSSWALKS SHALL HAVE 10' INSIDE DIMENSION UNLESS OTHERWISE SPECIFIED. 11. ALL CROSSWALKS, LIMIT LINES, STOP BARS, PAVEMENT ARROWS AND PAVEMENT LEGENDS SHALL BE THERMOPLASTIC UNLESS OTHERWISE SPECIFIED. 12. FIRE HYDRANT PAVEMENT MARKERS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST VERSION) AND SAN DIEGO REGIONAL STANDARD DRAWING M-19. 13. ALL MEDIAN NOSES AND FLARES SHALL BE PAINTED YELLOW. 14. ALL SIGNS SHALL BE STANDARD SIZE AS SHOWN IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST VERSION) UNLESS OTHERWISE SPECIFIED. 15. SIGN POSTS SHALL BE SQUARE PERFORATED STEEL TUBING WITH BREAKAWAY BASE PER SAN DIEGO REGIONAL STANDARD DRAWING M-45. 16. WHEN A SIGN IS ATTACHED TO A POLE, IT SHALL BE MOUNTED USING A STANDARD CITY OF CARLSBAD MOUNTING BRACKET WITH STRAPS. 17. EXISTING SIGNS REMOVED BY THE CONTRACTOR SHALL BE DELIVERED BY THE CONTRACTOR TO THE CITY OF CARLSBAD PUBLIC WORKS YARD AT 405 OAK AVENUE. 18. ALL SIGNS SHOWN ON THESE PLANS SHALL BE NEW SIGNS PROVIDED AND INSTALLED BY THE CONTRACTOR EXCEPT THOSE SIGNS SPECIFICALLY SHOWN AS EXISTING TO BE RELOCATED OR TO REMAIN. 19. (IF NECESSARY) WHERE R4-7 SIGN AND OM1-3 OBJECT MARKER ARE TO BE INSTALLED IN A 2-FOOT WIDE MEDIAN NOSE, THE R4-7 SIGN SHALL BE 18"X24" AND THE OM1-3 OBJECT MARKER SHALL BE 12"X12" --------------------- 3 PROPOSED PCC CURB & GUTTER PROPOSED SAWCUT OF EXISTING PAVEMENT PROPOSED 4" PCC SIDEWALK PAVEMENT (WIDTH PER PLAN) (SIZE PER PLAN) SDRSD G-2* & DETAIL SHT 2 SDRSD G-7* 185 LF 215 GENERAL NOTES STREET NOTES SIGNING AND STRIPING NOTES SEWER NOTES WATER NOTES DECLARATION OF RESPONSIBLE CHARGE (SHEETS 1-3) SOURCE OF TOPOGRAPHY PROJECT LOCATION BENCH MARK ~ • ' PROJECT ADDRESS ABBREVIATION LEGEND REFERENCE DRAWINGS INDEX OF SHEETS DEVELOPER LEGAL DESCRIPTION WORK TO BE DONE DESCRIPTION LEGEND STD. SYMBOL QUANTITY -------- ----64 --------64 ---- I I I I I . ' -------o----0 ---.o ---0 PLSA -------------------t l)J~ PLSAENGINEERING.COM t----+--+---------------,t----+---+-----+----1 ~ 11 CITY OF CARLSBAD I LJ t----+--+----------------+----+--t----+------t IMPROVEMENT PLANS FOR: 111LE SHEET APPROVED: JASON S. GELDERT t----+--+----------------+----+--t----+-----1 ::;;EN:;:;:Gl;:;N::;EE;;:Rl;::N::::G::::M::::AN:::A:::GER=:';:::::::R:::CE::::6::::3:::9::::12::::::::::EXP:::::l::::RES:::::::9=/::::3:;o:::/:2:::6::::::::::::D:::A:::lE:::::: OWN BY: ---1 PRO.ECT NO. I DRAWING NO. CHKD BY: __ DA 1E INITIAL DA 1E INITIAL DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OlHER APPROVAL CITY APf'ftOVAL RVWD BY: . NF NF Docusign Envelope ID: 89B44AEA-3553-4C16-9DBE-84E189EC8BFA 7/9/2025 NOTE: UTILITIES ARE KNOWN TO EXIST IN THE AREA. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. EXISTING UTILITIES ARE SHOWN PER AVAILABLE RECORD INFORMATION. CONTRACTOR TO VERIFY SIZE, DEPTH, LOCATION, AND MATERIAL PRIOR TO CONSTRUCTION. J:\ACTIVE JOBS\4099 RINCON-CARLSBAD-CHERRY AVE\CIVIL\DRAWING\IMPROVEMENT PLANS PLSA 4099 PLAN VIEW - GARFIELD STREET IMPROVEMENT PLAN SCALE: 1" = 10' HORIZONTAL SITE NOTES 1. EXISTING SURVEY MONUMENTS THAT ARE DISTURBED OR DESTROYED DURING CONSTRUCTION SHALL BE REPLACED BY A LICENSED LAND SURVEYOR AND A CORNER RECORD OF SURVEY SHALL BE FILED WITH THE COUNTY. 2. ALL UTILITIES SHOWN HEREON ARE PER BEST AVAILABLE RECORDS. CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD UPON DISCOVERY OF ANY DISCREPANCIES. 3. ALL STREET SIGNS, LIGHTS, LAMPS, UTILITIES, ETC. LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE PROTECTED IN-PLACE DURING CONSTRUCTION OR REPLACED TO THE SATISFACTION OF THE LAND DEVELOPMENT ENGINEERING DIVISION. 4. REMOVE AND REPLACE CURB, GUTTER AND SIDEWALK TO NEAREST JOINT. EX. SEWER LATERAL NOTE: EXISTING SEWER LATERALS TO BE REMOVED PER CITY OF CARLSBAD STANDARD 15000-3.12A STORM WATER REQUIREMENTS NOTES THE PROPOSED PROJECT WILL COMPLY WITH ALL THE REQUIREMENTS OF CURRENT CITY OF CARLSBAD STORM WATER STANDARDS AND THE REGIONAL MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4) PERMIT. THE PROPOSED PROJECT PROPOSES NEW AND / OR REMOVAL AND REPLACEMENT OF LESS THAN 5,000 SF OF IMPERVIOUS AREA AND WILL THUS BE CONSIDERED A STANDARD DEVELOPMENT PROJECT FOR STORM WATER PURPOSES. STREET CENTERLINE DATA TABLE - GARFIELD STREET NO BEARING/DELTA LENGTH RADIUS COMMENTS 1 C PUBLIC ROADL--N 34°02'01" E -- UTILITY NOTE: ABANDON EXISTING WATER SERVICE PER CITY OF CARLSBAD STANDARD SPECIFICATION 15000-3.12 B.6 & 7. CORPORATION STOP TO BE CLOSED AND WATER SERVICE PIPING TO BE DISCONNECTED FROM THE MAIN. METER BOX, CURB STOP, AND SERVICE PIPING TO BE REMOVED MINIMUM 24" BELOW FINISHED GRADE. 2 3 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. CHERRY BEACH HOMES BAK PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E , S U I T E 1 0 0 , S A N D I E G O , C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PUD 2024-0002 550-1 IMP. 2024-0011 GRAPHIC SCALE: 1" = 10' 0 20 40 60 TYPICAL SECTION - GARFIELD STREET NOT TO SCALE TYPICAL DETAIL - SAWCUT AC PAVEMENT NOT TO SCALE DETAIL - PROPOSED 'TYPE A' PCC PED RAMP SCALE: 1" = 3' HORIZONTAL SEE SHEET 3 FOR CHERRY AVENUE IMPROVEMENTS CONSTRUCTION NOTES 1 3 2 10 11 125 4 6 8 9 13 INSTALL 1" (DOMESTIC WITH FIRE SPRINKLER) WATER SERVICE. METER AND BACKFLOW PER CITY OF CARLSBAD W-5; INSTALL PVC SLEEVE BETWEEN METER AND BACKFLOW INSTALL 60 LF 6" PVC SEWER MAIN EXTENSION @ 7.0%; CONNECT TO EXISTING CO AND 6" VCP SEWER MAIN W/ TRANSITION COUPLING 3" GRIND AND OVERLAY CONSTRUCT TYPE A PCC PED RAMP PER SDRSD G-27A; SEE DETAIL THIS SHEET INSTALL SEWER CLEANOUT PER CITY OF CARLSBAD STD DWG S-6 CALTRANS 150-FT SIGHT DISTANCE VIEW CORRIDOR PER CALTRANS HIGHWAY DESIGN MANUAL AC PAVEMENT SAWCUT PER DETAIL THIS SHEET EXISTING SURVEY MONUMENT SHALL BE PROTECTED IN PLACE. MONUMENT SHALL BE REPLACED BY A LICENSED LAND SURVEYOR WHO SHALL FILE A CORNER RECORD WITH THE COUNTY IF DISTURBED OR DESTROYED. CONSTRUCT 8" PCC CURB & GUTTER PER MODIFIED SDRSD G-02 SEE DETAIL THIS SHEET TRENCH RESURFACING OF AC PAVEMENT PER CITY OF CARLSBAD STANDARD GS-26, GS-28 CONSTRUCT PCC DRIVEWAY APRON PER SDRSD G-14B AND CITY OF CARLSBAD GS-12 CONSTRUCT 4" THICK PCC SIDEWALK PER SDRSD G-07 SEE NOTE 4 THIS SHEET INSTALL 2 X 3" PVC SIDEWALK UNDERDRAIN PER SDRSD D-27 INSTALL 4" PVC SEWER LATERAL PER CITY OF CARLSBAD S-7 W/ CLEANOUT AT PROPERTY LINE 14 EXISTING TREES TO REMAIN UNLESS OTHERWISE NOTED GARFIELD STREET IMPROVEMENT PLAN / DETAILS LINE LENGTH DELTA/BEARING 16.50' Δ = 90°01'15" RADIUS 10.5' CURB DATA TABLE - CHERRY AVENUE 1 7 60 TC 56 TC 12+50 13+00 PROFILE VIEW - TOP OF CURB RIGHT SCALE: 1" = 10' HORIZONTAL; 1" = 4' VERTICAL 60 TC 56 TC PROFILE VIEW - CURB RETURN SCALE: 1" = 10' HORIZONTAL; 1" = 4' VERTICAL 60 TC 56 TC 60 TC 56 TC 1+00 1+20 REMARKS C&G PER SDRSD G-2 TYPICAL DETAIL - 8" PCC CURB & GUTTER NOT TO SCALE CONTRACTOR TO ENSURE CROSS SLOPE FROM AC PAVEMENT SAW CUT NOT TO EXCEED 4.5% SEWER LATERAL DATA TABLE - 4" PUBLIC SEWER LATERAL STREET STA. OF LAT @ MAIN IE @ MAIN LENGTH DROP TO MAIN LAT EL. @ PL (IE) LAT SLOPE GROUND EL. @ PL DEPTH BELOW PL (PL TO IE)PAD EL. (FT)UPSTREAM C/O RIM EL. BACKWATER VALVE REQ'D 13+02.93 50.25'51.45 IE1.20'51.430.5'61.05 NO8.75'2.0%60.8' 64 TC64 TC 13+10 X X X X X X X X X X X OEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE O E O E OE O E OE OE O E O E O E O E OEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEC W 63 . 1 1 T W 60 . 5 5 T C 60 . 1 4 F L 60 . 5 2 T C 60 . 1 2 F L 60 . 5 1 T C 60 . 1 0 F L 60 . 1 8 T C 60 . 0 8 F L 60 . 2 1 T C 60 . 1 1 F L 60 . 5 3 T C 60 . 1 4 F L 60 . 5 6 T C 60 . 1 1 F L 60 . 4 1 T C 59 . 9 4 F L 60 . 4 2 T C 59 . 9 3 F L 60 . 3 4 T C 59 . 9 1 F L 59 . 8 4 T C 59 . 7 9 F L 60 . 2 3 T C 59 . 7 6 F L 60 . 2 1 T C 59 . 6 7 F L 62 . 1 1 F F 69 . 8 R F 75 . 4 R F 61 . 1 3 61 . 0 9 61 . 0 6 60 . 9 2 60 . 9 1 60 . 9 0 60 . 8 8 60 . 8 9 60 . 8 9 60 . 9 8 60 . 6 0 60 . 4 4 60 . 6 1 60 . 7 5 60 . 7 0 60 . 6 6 60 . 9 4 60 61 61 61 ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) G G G G G G G W W W W W W W W SSSSSSSSSSSSSSS S S WWWWWWWWWWWWWWWWW W W W S S S S S S W W W W EEEEEE E W W W GGGGGGGGGGGGGGGGG E E E EEEEEE E E G G G G G GG G G G G G S 18 ' 30 ' 60 ' 30 ' 18 ' 12 ' GARFIELD STREET 1 1 1 EX. STREET TREE TO REMAIN EX. 8" ACP WATER MAIN PER DWG 538-2 5. 0 ' 6. 0 ' 2. 0 % 2. 0 % 9. 7 % 9. 7 % CH E R R Y AV E N U E EX. STREET TREES TO REMAIN PROP. LIMITS OF GRIND AND OVERLAY ST A 1 2 + 7 7 . 1 4 ~ 7 . 6 1 ' L T CO N N E C T T O E X . 8" A C P W A T E R M A I N 10 EX. 8" VC SEWER MAIN PER DWG 118-9EX. DRY UTILITY CABINET TO REMAIN EX. DRY UTILITY CABINET TO REMAIN FS 60.09FS 60.05 FS 60.55 FS 60.6 FS 60.6FS 60.6 3 3 16.0' (FS 60.5) 13 13 3+ 0 0 3+ 3 1 12+50 13+00 13+50 GA R F I E L D S T R E E T S T A 1 3 + 3 8 . 8 4 = CH E R R Y A V E N U E S T A 3 + 3 1 . 0 8 STA 13+17.80 ~20.73' LT C/L OF PROP. TYPE A PCC PED RAMP ST A 1 2 + 4 8 . 8 2 ~ 1 7 . 7 5 ' R T BE G I N I M P R O V E M E N T S MA T C H T O E X I S T I N G ST A 1 2 + 6 5 . 0 4 ~ 1 7 . 7 5 ' R T C/ L O F 1 6 ' W I D E P R O P . PC C D R I V E W A Y A P R O N 4 ST A 1 2 + 7 6 . 0 4 ~ 1 7 . 7 5 ' R T ST A 1 2 + 7 7 . 1 3 ~ 2 1 . 1 ' R T PR O P . W A T E R M E T E R 8 ST A 1 2 + 9 5 . 9 3 ~ 7 . 6 0 ' L T EX . W A T E R S E R V I C E AN D M E T E R TO B E R E M O V E D ST A 1 3 + 4 4 . 2 6 ~ 0 . 4 9 ' L T EX . S E W E R M H (R I M 6 0 . 9 ) (I E 5 0 . 4 0 ) PROJECT SITE (SEE DWG 550-1A FOR ONSITE IMPROVEMENTS) 1 11 P V T 1 " B A C K F L O W 14 14 5 EX. OVERHEAD UTILITY TO REMAIN EX. POWER POLE TO REMAIN EX. OVERHEAD UTILITY TO REMAIN DETAIL A THIS SHEET 0.2% S34°02'01"E 60.01' S5 5 ° 5 9 ' 1 3 " W 1 2 9 . 9 1 ' S5 5 ° 5 8 ' 5 0 " W 1 2 9 . 9 1 ' 0.2% REMOVE EX. CURB; CONST. 6" PCC C&G EX. PCC SIDEWALK TO REMAIN ROW ROW ST A 1 3 + 0 5 . 9 3 ~ 0 . 5 ' L T EX . S E W E R L A T E R A L T O BE R E M O V E D ; S E E E X . SE W E R L A T E R A L N O T E TH I S S H E E T CL CL CL CL EX. WATER SERVICE AND METER TO REMAIN APN: 204-231-04 BLOCK 1 LOT D MAP 1777 ST A 1 2 + 6 3 . 4 9 ~ 8 . 0 ' R T EX . G A S S E R V I C E A N D ME T E R T O B E R E M O V E D & R E P L A C E D P E R SE P A R A T E P E R M I T EX. STREET TREES TO BE REMOVED 4' X 4' GAS WELD HOLES 5 1 ST A 1 3 + 0 2 . 9 3 ~ 0 . 5 ' L T CO N N E C T T O E X I S T I N G 8" V C S E W E R M A I N (5 0 . 2 5 I E @ M A I N ) ; 5 1 . 4 5 IE @ L A T RIM 60.8 IE 52.05 7 3 REMOVE EX. CURB; CONST. 6" PCC C&G ST A 1 3 + 1 0 . 3 3 ~ 1 7 . 7 5 ' R T PC R 10 10 ST A 1 2 + 5 4 . 0 4 ~ 1 7 . 7 5 ' R T X XXXX X S S S S S S E E E E S 60.52 FS CHERRY AVE STA. 3+01.06 ~18.0' LT 60.31 TC 59.64 FL 8. 0 % 1. 5 % 60.48 FS GRARFIELD ST. PCR STA 13+10.33 ~17.75' LT 60.46 TC 59.96 FL 0.75% 0.75% 8.7% 1.4% MATCH TO EX. (60.61 FS) (1. 0 % ) 1.1%MATCH TO EX. (60.56 FS) 60.57 FS 60.54 FS 59.88 TC 59.88 FL 59.91 TC 59.91 FL 2.4% MATCH TO EX. (60.41 FS) MATCH TO EX. (60.51 FS)(1. 2 % ) (1. 2 % ) 1 1 0.2% 1.0 % GAR F I E L D STR E E T C H E R R Y A V E N U E 5' 6' 1' 12' 1. 5 ' 5' 6' 12 . 5 ' 1. 0 % 0.2% PL (2.0 % ) 11 5 5 14 LA LA EX. PCC SIDE WALK TO REMAIN EX. PCC SIDE WALK TO REMAIN EX. PCC CURB AND GUTTER TO REMAIN S5 5 ° 5 9 ' 1 3 " W 1 2 9 . 9 1 ' S34 ° 0 2 ' 0 1 " E 60.0 1 ' 5.9' 6.4' 1 (59.86 FS) PROP. PCC CURB AND GUTTER SEE SHEET 3 0. 9 % 1. 0 % 7. 5 ' 4. 0 ' 60.52 FS0.75% CHERRY AVE STA. 3+02.82 ~18.0' LT PCR 60.33 TC 59.66 FL 60.45 FS 59.95 FS 59.92 FS (59.98 FS) (60.02 FS) TRANSITION GUTTER CROSS SLOPE TRANSITION GUTTER CROSS SLOPE 4.0' 4. 0 ' (60.02 FS) 60.08 FS 59.78 FS2.2' 4. 0 ' 4' X 4' PAD LANDING; SLOPE NOT TO EXCEED 2.0% 2 60 4.0' RIM 60.8 IE 52.05 GU T T E R L I N E SA W C U T L I N E PCC CURB & GUTTER *STRUCTURAL SECTION 4" AC OVER 6" CLASS II AB OVER NATIVE SUBGRADE COMPACTED TO 95% REL. COMP.EXTEND BASE 6" BEHIND CURB 2.0' MIN 3.0' MIN 6" A B EXISTING AC PAVEMENT COLD PLAN AND OVERLAY (2" MIN. DEPTH) TO PROVIDE SMOOTH TRANSITION 6" *TO BE VERIFIED BY PROJECT GEOTECHNICAL ENGINEER BASED ON FIELD TESTED R-VALUE ROW EXISTING PCC 5' WIDE SIDEWALK VARIES EXISTING 6" PCC CURB EXISTING 6" ACP WATER MAIN TO REMAIN PER DWG 88-105 EXISTING PCC CURB AND SIDEWALK TO REMAIN EXISTING 8" VC SEWER MAIN TO REMAIN PER DWG 118-9 VARIES VARIESVARIES 60.0' 30.0' 30.0' 12.0' 36.0' 12.0' 18.0' ± TO TC 18.0' ± TO TC SAWCUT EXISTING AC PAVEMENT PER DETAIL THIS SHEET CL PL 5'PR O J E C T S I T E AP N : 2 0 4 - 2 3 1 - 0 5 EXISTING PAVEMENT TO REMAIN S T A 1 2 + 5 4 . 0 4 60 . 5 5 T C 60 . 0 5 F L S T A 1 2 + 6 5 . 0 4 CL O F P R O P . 1 6 - F T PC C D R I V E W A Y ST A 1 2 + 4 8 . 8 2 MA T C H T O E X . ; (6 0 . 6 1 T C ) (6 0 . 1 1 F L ) ST A 1 3 + 1 0 . 3 3 PC R 60 . 4 6 T C 60 . 0 6 F L S T A 1 2 + 7 6 . 0 4 60 . 5 4 T C 60 . 0 4 F L FS 60.09 FS 60.05 4 SOLID LINE REPRESENT PROPOSED TOP OF CURB DASHED LINE REPRESENTS EXISTING TOP OF CURB S T A 1 2 + 7 6 . 0 4 60 . 4 9 T C 60 . 0 9 F L 0.2%0.2% Δ=16.50' 4.13' Δ/4 4.13' Δ/4 4.13' Δ/4 4.13' Δ/4 60 . 4 3 T C 60 . 4 0 T C 60 . 3 7 T C 0.2%1.0% CH E R R Y A V E ST A . 3 + 0 2 . 8 2 ~ 1 8 . 0 ' L T 60 . 3 3 T C ; 59 . 6 6 F L GR A R F I E L D S T . ST A 1 3 + 1 0 . 3 3 ~ 1 7 . 7 5 ' R T 60 . 4 6 T C 59 . 9 6 F L DASHED LINE REPRESENTS PED RAMP CUT OUT 7" 6" 1 4 6" R=1/2" R=1/2" R=1" 0.5" 24" 8"2" WEAKENED PLANE JOINT 1.5" NOTES: 1. CONCRETE SHALL BE 560-C-3250 2. SEE SDRSD G-9 & G-10 FOR JOINT DETAILS 3. SLOPE TOP OF CURB AT 2% MAX TOWARDS GUTTER --------------------- I C ~ --I I I I -\ L....,- / ' I r { /, / ! J I I I -- I I I t I I - t t I I I ' ' I _l I lJ ' ----!------1\ \' \'· \\\ \'· I\'· \\I\'\' \\\1- 11 I\ \ \ \\ \ I\ I\ \ '\~ \\\\\ \'\ \ \\\\I / --/ I - - --+---\, \, \ \ \ , \ , I_ \ I ,\ -• l - --r \__ . r--~ / -+-, ------, / , :\~\,, \ \ \.~ ~ 1, \ ~ ... 1 ~ ~~ ,) \\ \ I\ \ ~ \ \ 1 ~ \_, \ ~ ~, r .. ' ...... -'-' "~i .>s-__ ;-L---1----i----'----_ ---~ -------m , . ,, -, , / -, _.,.-----, 1 -----. •-·--~ ., ., • 1 ____. ~-, -e--- -, @ • 'J~ I!:'. ·: ·,-/~ I "<::' ,,_ +--~"{W°-2,1 --_ I ~ ~ --\-1/ -l"T --_ --~~-J J ,~~-:::-" _ , I ~7 ) ",,.;< · U , '. ,_ * \ \ Cr /-' ;I I ~.: ' T7 \~ " -.... ' - -,. ..L , ~ "''"Y \, • I ' l ~ / ----~'<, j 1" i ~-i :, -r 11 -r-•• •. -~1 ,_ -"'\ ,, ( ~'o ~ t1\ r---:~ ~ \[11 ' / r-'\\ I '-+r{-.-' -- / I , ' 0 / / / I I ,._______,,,, 1, ( 'r-_; ·-'" ,;. - - -..I., - -...J. -,_ 0 0 ,)---, : '-~ ( ~---•1 , ~ Ill I -h.,f -------..... -!-... I 1 0 0 I I I I I I I I I I I I I I I I f-=- ~ " f I I I I I I I I I I I I I I I ' 0 I I I 1---1----+------i---,, / -i-, I I f 1 I I ' ~ . JU , J • b / V////, - "c)i"--- ~I I I ~ - <--7 y' I I I 0 0 0 0 0 0 0 I \-:r_..L___ T I ~1 ~ 1-----.--1 -,--I ---,-I -I ,---I ----,I PLSA1----------i l)J~---- PLSAENGINEERING.COM Lc==±==t=================+===l==t===t==3~11 c1TY oF CARLSBAD ILJ E==±==t=================+===l===t===r=~ IMPROVEMENT PLANS FOR: E==±==t=================+===l===t===r=~ APPROVED: Lc==±==t=================+===t==t===r=~ ENGINEERING MANAGER RCE 63912 EXPIRES 9/3Dl26 DAlE [~+==-'----------+DATETimTiAL"tDATEIINI~ DWN BY: --1 PRO.ECT NO. 1 DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: __ DA TE INITIAL BY REVISION DESCRIPTION DlHER APPROVAL CITY APf'ftOVAL RVWD : ENGINEER OF WORK JASON S. GELDERT NF NF Docusign Envelope ID: 89B44AEA-3553-4C16-9DBE-84E189EC8BFA 7/9/2025 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. CHERRY BEACH HOMES BAK PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E , S U I T E 1 0 0 , S A N D I E G O , C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PUD 2024-0002 550-1 IMP. 2024-0011 J:\ACTIVE JOBS\4099 RINCON-CARLSBAD-CHERRY AVE\CIVIL\DRAWING\IMPROVEMENT PLANS PLAN VIEW - CHERRY AVE IMPROVEMENT PLAN SCALE: 1" = 10' HORIZONTAL SITE NOTES 1. EXISTING SURVEY MONUMENTS THAT ARE DISTURBED OR DESTROYED DURING CONSTRUCTION SHALL BE REPLACED BY A LICENSED LAND SURVEYOR AND A CORNER RECORD OF SURVEY SHALL BE FILED WITH THE COUNTY. 2. ALL UTILITIES SHOWN HEREON ARE PER BEST AVAILABLE RECORDS. CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD UPON DISCOVERY OF ANY DISCREPANCIES. 3. ALL STREET SIGNS, LIGHTS, LAMPS, UTILITIES, ETC. LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE PROTECTED IN-PLACE DURING CONSTRUCTION OR REPLACED TO THE SATISFACTION OF THE CITY OF CARLSBAD. STORM WATER REQUIREMENTS NOTES THE PROPOSED PROJECT WILL COMPLY WITH ALL THE REQUIREMENTS OF CURRENT CITY OF CARLSBAD STORM WATER STANDARDS AND THE REGIONAL MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4) PERMIT. THE PROPOSED PROJECT PROPOSES NEW AND / OR REMOVAL AND REPLACEMENT OF LESS THAN 5,000 SF OF IMPERVIOUS AREA AND WILL THUS BE CONSIDERED A STANDARD DEVELOPMENT PROJECT FOR STORM WATER PURPOSES. STREET CENTERLINE DATA TABLE - CHERRY AVENUE NO BEARING/DELTA LENGTH RADIUS COMMENTS 1 C PUBLIC ROADL--N 55°59'13" E -- 3 3 GRAPHIC SCALE: 1" = 10' 0 20 40 60 TYPICAL SECTION - CHERRY AVENUE NOT TO SCALE 46 CL 50 CL 54 CL 58 CL 54 CL 58 CL 62 CL 60 TC 56 TC 60 TC 56 TC 2+00 2+50 PROFILE VIEW - CL CHERRY AVENUE SCALE: 1" = 10' HORIZONTAL; 1" = 4' VERTICAL PROFILE VIEW - TOP OF CURB LEFT SCALE: 1" = 10' HORIZONTAL; 1" = 4' VERTICAL 2+00 2+501+50 LINE LENGTH DELTA/BEARING RADIUS 56.86'N 55°59'24" E - SLOPE 7.0% REMARKS 6" PVC SDR-35 MAIN1 SEWER MAIN DATA TABLE - CHERRY AVENUE LINE LENGTH DELTA/BEARING 131.21' N 56°07'19" E REMARKS 8" C&G PER DETAIL SHEET 2 CURB DATA TABLE - CHERRY AVENUE 2 SEE SHEET 2 FOR GARFIELD STREET IMPROVEMENTS NOTE: UTILITIES ARE KNOWN TO EXIST IN THE AREA. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES OR STRUCTURES LOCATED AT THE WORK SITE. EXISTING UTILITIES ARE SHOWN PER AVAILABLE RECORD INFORMATION. CONTRACTOR TO VERIFY SIZE, DEPTH, LOCATION, AND MATERIAL PRIOR TO CONSTRUCTION. SEWER LATERAL NOTE: UPON START OF CONSTRUCTION, CONTRACTOR TO FIELD VERIFY CONDITION OF EXISTING SEWER LATERAL AND NOTIFY ENGINEER OF RECORD IF CONDITION IS NON-SATISFACTORY UTILITY NOTE: ABANDON EXISTING WATER SERVICE PER CITY OF CARLSBAD STANDARD SPECIFICATION 15000-3.12 B.6 & 7. CORPORATION STOP TO BE CLOSED AND WATER SERVICE PIPING TO BE DISCONNECTED FROM THE MAIN. METER BOX, CURB STOP, AND SERVICE PIPING TO BE REMOVED MINIMUM 24" BELOW FINISHED GRADE. 1 3 2 10 11 12 5 7 4 6 8 9 13 INSTALL 4" PVC SEWER LATERAL PER CITY OF CARLSBAD S-7 W/ CLEANOUT AT PROPERTY LINE PER CITY OF CARLSBAD S-7; SEE SEWER LATERAL DATA TABLE FOR BACK WATER VALVE REQUIREMENTS INSTALL 1" (DOMESTIC WITH FIRE SPRINKLER) WATER SERVICE METER AND BACKFLOW PER CMWD W-5 ; INSTALL PVC SLEEVE BETWEEN METER AND BACKFLOW INSTALL 60 LF 6" PVC SEWER MAIN EXTENSION @ 7.1%; CONNECT TO EXISTING CO AND 6" VCP SEWER MAIN W/ TRANSITION COUPLING PER CITY OF CARLSBAD APPROVED MATERIAL LIST 3" GRIND AND OVERLAY CONSTRUCT TYPE A PCC PED RAMP PER SDRSD G-27A; SEE DETAIL SHEET 2 INSTALL SEWER CLEANOUT PER CITY OF CARLSBAD STD DWG S-6 CALTRANS 150-FT SIGHT DISTANCE VIEW CORRIDOR PER CALTRANS HIGHWAY DESIGN MANUAL AC PAVEMENT SAWCUT PER DETAIL THIS SHEET EXISTING SURVEY MONUMENT SHALL BE PROTECTED IN PLACE. MONUMENT SHALL BE REPLACED BY A LICENSED LAND SURVEYOR WHO SHALL FILE A CORNER RECORD WITH THE COUNTY IF DISTURBED OR DESTROYED. CONSTRUCT 8" PCC CURB & GUTTER PER MODIFIED SDRSD G-02 SEE DETAIL SHEET 2 TRENCH RESURFACING OF AC PAVEMENT PER CITY OF CARLSBAD STANDARD GS-26, GS-28 CONSTRUCT PCC DRIVEWAY APRON PER SDRSD G-14B AND CITY OF CARLSBAD GS-12 CONSTRUCT 4" THICK PCC SIDEWALK PER SDRSD G-07; 5-FT WIDE INSTALL 2 X 3" PVC SIDEWALK UNDERDRAIN PER SDRSD D-27 14 SEWER LATERAL DATA TABLE - 4" PUBLIC SEWER LATERAL STREET STA. OF LAT @ MAIN IE @ MAIN LENGTH DROP TO MAIN LAT EL. @ PL (IE) LAT SLOPE GROUND EL. @ PL DEPTH BELOW PL (PL TO IE)PAD EL. (FT)UPSTREAM C/O RIM EL. BACKWATER VALVE REQ'D 2+13.27 49.7'51.5 IE1.20'59.130.25'59.5 YES7.6'2.0%59.1' 2+16.27 49.9'51.7 IE 60.1 59.5 YES7.5'2.0%59.2' STREET TREE NOTES EXISTING STREET TREE TO REMAIN EXISTING STREET TREE TO BE REMOVED 1 2 46 CL 50 CL 1.20'30.25' CHERRY AVENUE IMPROVEMENTS P&P CONSTRUCTION NOTES 1+70 3+00 X X X X XXXXXXXXXX OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OE OE OE O E O E O E OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E O E OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE 61.43 TW 61.34 TW 61.31 TW 63.25 TW 57.81 TW 63.20 TW 60.56 TC 60.11 FL 60.41 TC 59.94 FL 60.42 TC 59.93 FL 60.34 TC 59.91 FL 59.84 TC 59.79 FL 60.23 TC 59.76 FL 60.21 TC 59.67 FL 59.96 TC 59.27 FL 59.25 TC 58.67 FL 58.67 TC 58.56 FL 57.91 TC 57.84 FL 58.33 TC 57.77 FL 57.48 TC 56.84 FL 57.04 TC 56.40 FL 56.69 TC 55.89 FL 59.80 FF 62.11 FF 62.16 FF 85.0 RF 81.9 RF 75.4 RF 80.0 RF 80.1 RF 54.98 57.85 58.76 58.66 59.71 59.66 59.62 59.84 59.82 59.2958.55 58.92 58.19 59.1258.62 59.5557.76 60.92 60.91 60.90 60.98 61.00 60.60 60.44 60.94 59.61 57.1655.93 55.90 56 57 58 59 60 61 60 59 5 8 5 8 61 1 STORY BUILDING EXISTING 2 STORY BUILDING ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )( ) ( )( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) G G G G G G G G G G G G G G G G G G G G G G G G WWWWWWWWWWWWWWWWWWWWWW S S S S S S S S S S S S W W W W W W W W W W W W W W W W W W W S S S S S S S W W W W S S S S S S W W W W W W S S S S S S S E E E E E E EE W W W S SD SD SD SD SD SD SD SD SD SD SD SD SD SD G G G G G G G G G G G G E E E E E E E E EEEEEEEEE JT JT JT JT G G G G G G G G SSSS S 30 . 0 ' 60 . 0 ' 12 . 0 ' 6. 0 ' 5. 0 ' 1. 0 ' EX. TEMPORARY POWER POLE TO REMAIN EX. WATER SERVICE AND METER TO REMAIN EX. PCC NON CONTIGUOUS SIDEWALK TO REMAIN PROP. TRANSFORMER PER SEPARATE SDGE WORK ORDER 1 6 16.0' 5 2. 0 % 2. 0 % 2. 0 % 2. 0 % FS 59.4 FS 59.3 FS 59.7 FS 59.8 (2 . 5 % ) 5.0'6.0'FS 58.2 FS 58.8 FS 58.7 FS 58.1 16.0' 2+00 3+00 3+31 13 + 0 0 13 + 5 0 ST A 1 + 7 9 . 9 0 ~ 1 8 . 0 ' L T ST A 1 + 8 4 . 4 8 ~ 1 8 . 0 ' L T ST A 2 + 0 2 . 4 8 ~ 1 8 . 0 ' L T SEWER CO RIM 59.2 IE 52.0 ST A 2 + 2 3 . 1 5 ~ 1 8 . 0 ' L T ST A 2 + 4 1 . 1 5 ~ 1 8 . 0 ' L T ST A 1 + 9 3 . 4 8 ~ 8 . 0 ' L T C/ L O F P R O P . 1 2 ' W I D E PC C D R I V E W A Y A P R O N 4 ST A 2 + 3 2 . 1 5 ~ 1 8 . 0 ' L T C/ L O F P R O P . 1 2 ' W I D E PC C D R I V E W A Y A P R O N 4 ST A 2 + 4 8 . 4 2 ~ 2 1 . 3 ' L T PR O P . W A T E R M E T E R PE R C M W D W - 3 ST A 2 + 0 3 . 2 7 ~ 2 1 . 2 ' L T PR O P . W A T E R M E T E R P E R C M W D W - 3 ST A 3 + 1 0 . 3 4 ~ 2 1 . 0 4 ' L T C/ L O F P R O P . T Y P E A PC C P E D R A M P ; S E E DE T A I L A S H E E T 2 11 EX. 6" VC SEWER MAIN PER DWG 118-9 PROPOSED LIMITS OF GRIND AND OVERLAYEX. 8" PVC WATER MAIN PER CMWD DWG 937-3 PROP. LIMITS OF GRIND AND OVERLAY 18 . 0 ' 18 . 0 ' 30 . 0 ' PROPOSED ELECTRICAL CONDUIT PER SEPARATE SDGE PERMIT EX. POWER POLE P294107 TO REMAIN; PROP. CONDUIT RISER AND COVERT TO PRIMARY CABLE POLE PER SEPARATE SDGE PERMIT EX. FIRE HYDRANT TO REMAIN 1 EX. POWER POLE TO REMAIN EX. 8" ACP WATER MAIN PER DWG 538-2 CHERRY AVENUE GA R F I E L D S T R E E T 3 3 3 3 3 10.0' 8 8 9 9. 7 % 2 EX. PCC DRIVEWAY TO BE REMOVED 9. 7 % (4 . 0 % ) 3.3%(4.3%) FS 58.6 FS 58.8 12 ST A 2 + 0 3 . 2 7 ~ 1 2 . 2 4 ' R T CO N N E C T T O E X . 8" P V C W A T E R M A I N ( U N I T 1 ) FS 57.4 FS 57.8 8 ST A 2 + 4 8 . 4 2 ~ 1 2 . 2 4 ' R T CO N N E C T T O E X . 8" P V C W A T E R M A I N ( U N I T 2 ) 8 13 13 ST A 2 + 1 3 . 2 7 ~ 0 . 2 8 ' R T CO N N E C T T O P R O P . 6 " PV C S E W E R M A I N ( U N I T 1 ) IE @ M A I N 4 9 . 7 IE @ L A T 5 0 . 9 ST A 2 + 1 6 . 2 7 ~ 0 . 2 8 ' R T CO N N E C T T O P R O P . 6 " PV C S E W E R M A I N ( U N I T 2 ) IE @ M A I N 4 9 . 9 IE @ L A T 5 1 . 1 7 7 ST A 2 + 2 4 . 6 9 ~ 0 . 2 8 ' R T PR O P . S E W E R C O RI M 5 9 . 5 IE 5 0 . 5 CHERRY AVENUE STA 3+31.08 = GARFIELD STREET STA 13+38.84 ST A 1 + 6 6 . 5 1 ~ 0 . 1 7 ' R T EX . S E W E R C O ; ( R I M 5 7 . 6 ) (I E 4 6 . 3 4 ) ; R E M O V E EX I S T I N G C L E A N O U T PROJECT SITE (SEE DWG 550-1A FOR ONSITE IMPROVEMENTS) 1 1 PV T 1 " B A C K F L O W 1 1 14 1 1 1 1 1 1 S55°59'13"W 129.91' S3 4 ° 0 2 ' 0 1 " E 6 0 . 0 1 ' 14 CL CL CLCL 2 SEWER CO RIM 59.1 IE 51.6 PV T 1 " B A C K F L O W 30.0' 17.5' EXISTING OVERHEAD UTILITY TO REMAIN EXISTING OVERHEAD UTILITY TO REMAIN EX. GUY WIRES TO REMAIN EX. PED RAMP TO REMAIN N3 4 ° 0 1 ' 5 5 " W 5 9 . 9 9 ' ROW APN: 204-231-07 PARCEL 1 PM 22001 ROW 1 1 EX. PCC CURB AND GUTTER TO REMAIN 2. 0 % ST A 2 + 2 1 . 2 7 ~ 5 . 2 5 ' R T CO N N E C T T O G A S M A I N PE R S E P A R A T E S D G E PE R M I T ST A 1 + 8 2 . 6 1 ~ 5 . 2 5 ' R T CO N N E C T T O G A S M A I N PE R S E P A R A T E S D G E PE R M I T 2 2 10 4' X 4' GAS WELD HOLE4' X 4' GAS WELD HOLE 2.0%1.0% ST A 1 + 7 1 . 1 3 ~ 1 8 . 0 ' L T BE G I N I M P R O V E M E N T S MA T C H T O E X I S T I N G ST A 3 + 0 2 . 8 2 ~ 1 8 . 0 ' L T PC R ST A 2 + 6 5 . 0 0 ~ 1 8 . 0 ' L T GR A D E B R E A K 57.35 FL/IE 5. 0 ' (5 6 . 7 5 F S ) ST A 1 + 5 0 . 0 0 (5 8 . 7 7 F S ) ST A 2 + 0 0 . 0 0 (5 9 . 8 7 F S ) ST A 2 + 5 0 . 0 0 ST A 2 + 0 3 . 2 7 CO N N E C T T O E X . 8" P V C W A T E R M A I N 8 ST A 2 + 4 8 . 4 2 CO N N E C T T O E X . 8" P V C W A T E R M A I N 8 ST A 2 + 1 3 . 2 7 IE @ M A I N 4 9 . 7 IE @ L A T 5 0 . 9 ST A 2 + 1 6 . 2 7 IE @ M A I N 4 9 . 9 IE @ L A T 5 1 . 1 7 ST A 1 + 5 8 . 3 8 EX . W A T E R S E R V I C E CO N N E C T I O N 7 ST A 2 + 2 4 . 6 9 PR O P . S E W E R C O 59 . 5 R I M IE 5 0 . 5 ST A 1 + 6 6 . 5 1 EX . S E W E R C O (R I M 5 7 . 6 ) ; ( I E 4 6 . 3 4 ) ; RE M O V E E X I S T I N G CL E A N O U T PROP. 6" PVC SEWER MAIN EX. 8" PVC WATER MAIN PER CMWD DWG 937-3 APPROX. EXISTING GRADE OF CENTERLINE EX. 6" VC SEWER MAIN PER DWG 118-9 7.1% (2.0%) (4.0%) (2.2%) 12 APPROX. DEPTH OF EXISTING GAS MAIN ST A 1 + 8 2 . 6 1 CO N N E C T T O GA S M A I N P E R SE P A R A T E S D G E PE R M I T ST A 2 + 2 1 . 2 7 CO N N E C T T O GA S M A I N P E R SE P A R A T E SD G E P E R M I T ROW EXISTING PCC 5' WIDE SIDEWALK 2.0% EXISTING 6" PCC CURB & GUTTER EXISTING 8" PVC WATER MAIN TO REMAIN PER DWG 937-3 EXISTING PCC SIDEWALK TO REMAIN PROP. 8" PVC SEWER MAIN VARIESVARIESVARIES 60.0' 30.0' 30.0' 12.0' 36.0' 12.0' 18.0' ± TO TC 18.0' ± TO TC CLPL 5'PR O J E C T S I T E AP N : 2 0 4 - 2 3 1 - 0 5 SAW CUT EXISTING PAVEMENT PER DETAIL SHEET 2 PROPOSED 8" PCC CURB AND GUTTER PER MODIFIED SDRSD G-2 SEE DETAIL SHEET 2 ST A 1 + 7 9 . 7 0 ~ 1 8 . 0 ' L T DU A L D - 2 7 C R U B O U T L E T S IE 5 7 . 1 ST A 1 + 9 3 . 4 8 C/ L O F P R O P . P C C DR I V E W A Y A P R O N 4 ST A 2 + 3 2 . 1 5 C/ L O F P R O P . P C C DR I V E W A Y A P R O N 4 DASHED LINE REPRESENTS EXISTING TOP OF CURB ST A 1 + 8 4 . 4 8 TC 5 7 . 9 6 ; F L 5 7 . 3 ST A 2 + 0 2 . 4 8 TC 5 8 . 5 8 ; FL 5 7 . 9 2 ST A 2 + 4 1 . 1 5 TC 5 9 . 5 2 ; F L 5 8 . 8 6 FS 58.8 DASHED DOT LINE REPRESENT PROPOSED FLOWLINE FS 57.8 FS 57.4 FS 58.6 ST A 2 + 2 3 . 1 5 TC 5 9 . 1 7 ; FL 5 8 . 5 0 2.0% 3.3% ST A 2 + 1 5 . 0 0 GR A D E B R E A K TC 5 9 . 0 0 T C ; FL 5 8 . 3 3 3.3%2.0% SOLID LINE REPRESENT PROPOSED TOP OF CURB ST A 1 + 7 1 . 1 3 BE G I N I M P R O V E M E N T S MA T C H T O E X I S T I N G (T C 5 7 . 5 ) ( F L 5 6 . 8 3 ) ST A 2 + 6 5 . 0 GR A D E B R E A K TC 5 9 . 9 8 T C ; FL 5 9 . 3 2 ST A 3 + 0 2 . 8 2 PC R TC 6 0 . 3 3 ; FL 5 9 . 6 6 ST A 2 + 8 0 . 0 TC 6 0 . 1 2 ; FL 5 9 . 4 6 1.0%2.0% 2 --------------------- I I I - I I I +-I I I I I I ---------, f t - t -7 r-I I I ' I I I q I I ' I I -I ,, ' I I _\ I I I -------~- '--.. \ / -/ /~ '/ 7 / ---7 / -\. - -f--- -- I I I c I C ,~ --+--~ I I I I '--7 \ / ~ ' T t I I - I \ t ' -+ i t t I I I t - I I I I r . . . - - -\ I t I I I t /, I I I I V t t ,,..-: I L~ r . . . C -- 0 0 I I I I - ' -• I I - r- I - f I - - I - I C I ' ' ' I '--" ' I +----'-~--E-= I I \ • t ·7 1 I I I I r I I I I I I I I I I -I I l I l l I . I 1 1 I I I I I . ~ ' ~ I I I t -T T I I ' I ,. I ' I I l I I I I I ' C l I I I l e -- C C c~ I - I I I I I . . I I I I - ~ I I I I ["-. I -"- L: L-.l -'----' • L...l I I I --I -I -I i r • -- - 0 0 0 0 0 0 0 0 I I r -1_ ---• ■1~@~ll~-11~11111~1 I I 11~1 I I 11~1~ 11 -~I I I II~ 1 l;II I I I lffi ~w1 slJi1 am[ 11 ljm I lli ""1111l;:::-11111'""'111 ~Jmjl I I I JfTTT'I I I IJ;:-1~17'-!iT 0 0 0 0 0 0 0 0 1---+--~1--------------1----1----1----1----' APPROVED: JASON S. GELDERT f---+--~f--------------1----1---1---1-----1 ;::EN::::GIN::::EE::Rl::::NG::::::M:::::AN::A:::GER:;'::::R:::CE:::::6:::39:::::::12:::::::::::EXP:::::l:::RES=9 /::::::3:'=o /:=2!6:::::::::::::DA::::lE= DATE INITIAL DATE INITIAL OWN BY: --1 PROJECT NO. I DRAWING NO. 1-----''----+---'----I CHKD BY: -- DlHER APPROVAL CITY APf'ftOVAL RVWD BY: _ DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION NF NF Docusign Envelope ID: 89B44AEA-3553-4C16-9DBE-84E189EC8BFA 7/9/2025