HomeMy WebLinkAbout5901 PRIESTLY DR; 301; FPC2019-0138; PermitPERMIT REPORT ity of Carlsbad Ui@ Print Date: 11/14/2024 Permit No: FPC2019-0138 Job Address: 5901 PRIESTLY DR, # 301, CARLSBAD, CA 92008-8825 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120610300 Track #: Applied: 06/18/2019 Valuation: $158,134.00 Lot #: Issued: 06/24/2019 Occupancy Group: Project #: Finaled Close Out: 09/26/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: GEl CONSULTANTS -RELOCATE/ADD (30) PENDENT SPRINKLERS FOR NEW SUSPENDED CEILINGS Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ S 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov A I TAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 19283 GEl Suite 301 5901 Priestly Drive, Suite 301 Carlsbad, CA 92008 FPC20I9-0138 5901 PRIESTLY DR #301 GEl CONSULTANTS -RELOCATE/ADD (30) PENDENT SPRINKLERS FOR NEW SUSPENDED CEILINGS 2120610300 6/18/2019 FPC20I9-0138 ZURN Model 350ADA EXISTING WILKINS Double Check Detector Assembly Application Designed for installation on water lines in fire protection sys- tems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350ADA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Horizontal & Vertical) ASSE® Listed 1048 AWWA Compliant C510 (with gates only), and C550 CSA® Certified B64.5 UL® Classified C-UL® Classified FM® Approved Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NYC MEA221-04M-2 (2 1/2' - 8') Meets the requirements of NSF/ANSI 61* (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backf low Assembly 3/4' Model 950XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved electrostatic epoxy finish Internals Stainless steel, 300 Series NORYLTm Fasteners & Springs Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTm Features Sizes: 2 1/2", 3"', 4", 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 *2 1/2' & 3" sizes use 4" body & reducer couplings Dimensions & Weights (do not include pkg.) MODEL 350ADA SIZE mm WEIGHT LESS SHUTOFF VALVES lbs. kg OSY GATE VALVES FLANGED Ibs. I kg- OSY GATE VALVES GROOVED lb& kg BUTTERFLY VALVES FLANGED ft. I kg BUTTERFLY VALVES GROOVED lbs. kg 2 1/2 65 105 48 192 87 184 83 157 71 147 67 3 80 104 47 210 95 200 91 162 73 148 67 4 100 91 41 230 104 204 93 147 66 139 63 6 150 141 64 362 164 332 151 246 111 215 98 200 302 137 762 346 738 335 491 223 445 202 10 250 355 161 1024 464 902 409 628 285 570 259 ISP(MSSI *1 (with OS&Y gates) (with BG valves) Options (Suffixes can be combined) - with flanged end OS & V gate valves (standard) El L - less shut-off valves (grooved body connections) El LM - less water meter - with remote reading meter - with gallon meter (standard) El CFM - with cu ft meter El CMM - with cu meter meter El G- - with grooved end connections El FG - with flanged inlet connection and grooved outlet connection El P1 - with Post Indicator Gate Valves BG - with grooved end butterfly valves with integral supervisory switches BF - with flanged end butterfly valves with integral supervisory switches —509 - with AWWA C509 gate valves Accessories Repair kit (rubber only) Thermal expansion tank (Model XT) El OS & V Gate valve tamper switch (OSY-40) MODEL 350ADA with OS&Y option MODEL DIMENSION (approxImate) 350ADA SIZE in min A In mm AWITH BUTTERFLY VALVES In mm BLESS GATE VALVES In mm C In mm D In mm E OPEN In mm E OS&Y CLOSED In I mm E WITH BUTTERFLY VALVES In mm F In I mm 3 In mm 21/2 65 351/81 892 321/8 816 201/8 511 41/2 114 9 229 173/4 451 153/81 391 81/4 210 6 152 71/4 184 3 _2L 361/8 918 33 838 201/8 511 41/2 114 9 229 201/4 514 17 432 81/2 216 6 152 71/4 184 4 100 381/4 972 331/4 845 197/8 505 11/2 114 9 229 221/2 572 181/4 464 9 229 6 152 8 203 6 150 471/4 1200 401/4 1022 257/8 657 51/2 140 101/2 267 1301/2 775 241/4 616 101/4 260 7 178 10 254 8 200 62 1575 55 1397 381/2 978 13 254 12 305 37 940 281/21 724 1 12 1 305 81/2 2161 11 1 279 10 250 645/8 1641 59 1499 381/2 978 1-3 254 12 305 455/8 1159 343/41 883 1 131 330 181/212161 12 1 305 Attention: Model 350ADA (grooved body) and Model 350DA (flange body) have different lay lengths. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited - - 3544 Nashua Drive, Mississauga, Ontario L4V 112 Ph. 805-405-8272, Fax 905-405-1292 www.zurn.com Rev. H Date: 4/17 Document No. BF-350ADA Patent No. 5, 913, 331 Product No. Model 350ADA Page 1 of 2 Flow Characteristics 0.0 2 15 U, 0. 10 MODEL 350A0A2 1/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (us) 12.6 25.2 37.9 ORated Flow (established by approval agencies) 50.5 104 t 69 Ui U, 0, U, a 0 200 400 600 800 — FLOW RATES (GPM) MODEL 350ADA 6", 8" & 10" (STANDARD & METRIC) FLOW RATES (I/n) 0.0 63.1 126.2 189.3 252.4 15 104j 10 69 Co (0 U) U, 90 j 0 0 1000 2000 3000 4000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12(305mm) and a maximum of 30(762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 21/2" 75 112 149 224 3" 115 173 230 346 4 198 298 397 595 6 450 675 1 900 1351 8" 780 1169 1559 2339 101, 1229 1843 2458 3687 12" 1763 2644 3525 5288 PROTECTIVE MODEL 350ADABG (Vertical Installation) MODEL 350ADA (Outdoor Installation) Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and sup- plied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be Noryl (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 350ADA. Zum Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to I411/19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. %tauIicf 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart For K-Factor when pressure is measured in Oar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. j updated 07/2014 © 2014 victaulic Company. All rights reserved. 1 iCtaUlic victaulic.com I Sprinklers I FireLocke li K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS 051000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: El Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: Open End: V27 LI Recessed: V27-2 Sprinkler Finishes: LI Plain Brass LI Chrome plated LI White painted3 LI Black painted3 LI Custom painted-3 LIII Proprietary Nickel Teflon2 coating3 LI VC-2504 155, 200, 286 SR Only: LI Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 2 \,#9taUJic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: APPROVALS/LISTINGS ____________ ____________ Model V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1(7" 1/2" 1/2" 1/2" 1/2 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor SI.5 81 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type upright Pendent Recessed upright Pend ent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135"/57°c 1350F/570C 1550 F/68"c 155°F/68°C 135"F/57"c 135"F/57"C 135"F/57"C 135"F/57°C 17s°/79"c 175°F/79"C 155°F/68°C 155°F/68"c 155°F/68"c 155"F/68°c cuLus 200"F/93"c 200"F/93"C 175°F/79"c 175"F/79"C 175"F/79"C 175°F/790C 286°F/141"c 286"F/141"c 200°F/930C 200°F/93°c 200°F/930c 200"F/93°C 360"F/182°C 360"F/182°C 286°F/141°C 286"F/141"c 286"F/1410c 135"F/57"C 135"F/57°C 1550F/68"c 155"F/68"C 1350F/57"c 135°F/570c 135°F/570C 135"F/57°C FM 175"F/79"c 175"F/79"C 155"F/68°C 155"F/68°C 155"F/68"c 155°F/68"C 200"F/93"c 200°F/93"c 175"F/79"c 175°F/79"C 1750F/79"C 175"F/79"C 286"F/141"C 286"F/141"C 200"F/93°C 200"F/93"C 200"F/930c 200"F/93"c 360°F/1820C 360"F/1820c 2 860F/141°C 2860F/141"C 135"F/57"C 135"F/570c 155°F/68"C 155"F/68"C 135"F/57°c 135°F/57°C 135°F/57°C 135°F/57°c NYC/MEA 62-99-E 175°F/79°C 175°F/79°c 155"F/68°c 175°F/79"C 1550F/68°c 175"F/79"C 155"F/68°c 175"F/79"C 155°F/680C 200"F/93"C 200"F/93"C 200"F/93°C 200"F/93°C 200"F/93°C 175°F/79"C 286°F/141°C 286°F/1410C 286°F/141"C 2860F/141"C 2860F/1410C 200"F/93"C 360"F/182"C 360"F/182"C 135°F/57°C 135"F/57°C 1550F/68"C 155°F/68"C 135°F/57"C 1350F/57"C 135°F/57"C 135°F/57"c 175°F/79"C 175"F/79"C 155°F/68"c 155°F/68"C 155°F/68"C 155°F/68"C CSFM 7690-0531:112 200"F/93"C 200"F/93"C 1750F/790C 1750F/79°C 1750F/790C 175"F/79°C 2860F/1410C 286°F/141°C 200"F/93°C 200"F/93°C 200"F/93°C 200"F/930C 360°F/1 82°C 360°F/182°C 286°F/1410C 286°F/141°C 286°F/141"C 135"F/57"C 155"F/68°C 1350F/57"C LPCB 175°F/79°C None None 155"F/68°C None None 200"F/93°C 175°F/79°C 286"F/141°C 200°F/93°C 3600F/182"C 135"F/57"C 135"F/57"C 155"F/68"C 155"F/68"C 135"F/570C 135"F/57°C 135"F/57"C 135"F/57"C VNIIPO 175"F/79°C 175°F/790C 155°F/68° 1550F/680C 175°F/79"CC 155°F/68°C 155°F/68°C 200"F/93"C 200°F/93"C 175"F/79"C 175°F/79°C 175°F/79°C 286"17141°C 286"F/141°C 200"F/93°C 200"F/93"C 200"F/930C200"F/930C 360°F/182"C 360°F/1820C 2 86°F/141"C 286°F/141°C ZSTZ ZSTX K-ZSTZ K-ZSTZ ccc 155"F/68°C 155°F/680C None 1550F/68"c 155°F/68"C None 200"F/93°C 200°F/930C 200°F/930C 200"F/93°C 135°F/57°C 155°F/68"c 135°F/57"C 175°F/79"c 155°F/68"C VdS 200"F/93 ° c None None 175"F/79°C None None 286°F/141"c 200°F/93"C 360°F/1820C 86°F/141"C 2 135"F/57"C 155"F/68"C 35°F/570C 1 175"F/79 "C 155"F/68"C CE 200'F/93"C None None 175"F/79"C None None 286"F/141"C 200°F/93"C 360"F/182°C 86°F/1410C 2 For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victauric Company. All rights reserved. victaulic.com 3 \ Ai taUIIc 17Ae"/ 37 mm 2 60 1W! 2W! 41 mm 60 mm victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/60 mm Max. Hole 2"/51 mm Mm. Hole 1 trrirru iJai Typical Ceiling Tile iu Imm 151a/ -Finished Surface 30 nm MAXIMUM RECESS 2°Aa,' 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 2751 mm Mm. Hole 24 mm X/1 Typical Ceiling Tile IVI 24 mm Finished Surface—/ MAXIMUM RECESS 2W/ - 75 mm MAXIMUM EXTENSION 3/4 Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victauliccom 4 Jtauuic 17mm 11 43 M victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent uistrroution Vatterns - I rajectory I- _T* VJ FIN r 67 8' 10 12' 14' Own 12., 1.8,, 2.4,,, 3.0,, 3.7,, 4.3,,, Models V2703, V2704 K5.6 Standard upright Distribution Patterns - Trajectory 1111 - - - -I- - - - \ \ \ 2' 4' 6' 8' 10' 12' . 14' 16' 0.6m Urn 18,,, 2.4. 3.0,, 3.7,,, 4.3m 4.0,,, NOTES Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to fallow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 5 _1#9taUlic.' 7ps1 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7ps1 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - Ft C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 Ff38 C Orange Ordinary C 155 F/68 C 100 Ff38 C Red Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 Ff65 C Green High J 286 Ff141 C 225 F8/107 C Blue Extra High K 360 F/182 C 300 F/149 C Purple - M Open - No Bulb Standard response only. 8 150f65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent / / V2707,V2708 Recessed Pendent V2703, V2704 Upright WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. O The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers lnstallolioo and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 6 'J'tauIic Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED1 <> APPROVE) Do £ ONFSA NFPA 211 SCHEDULE 10 PIPE SPECIFICATIONS ., -. NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1315 1.097 1527 141 lbs/ft 1820 91 __ J6orT442J[ Th9i nj 61 11/2 1900 ' 1.682 776 L _2.09 lbs/ft '1 Th053 61 L:.:- 2-1/2 24j"5 2.635 492 153 lbs/ft -5''.'89-3 30 LT3T i1LEJL .26b —_3-!S4 -E-434 lbs/ft [795f Th1 4 __-4.500 .4.260 250 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 - 1.315 1.049 1.00 1 1.68 lbs/ft 2.055 70 Lij1E 1660 T Th38Oj10O --f,27 1ITSIft 1E ITL:T1 1 1/2 1 900 1.616 11 1.00 2.72 lbs/ft 3.602 44 2 2375 2O67''ji 100 L 36 JPs/ft. if 5114 ijJ_____3 . 1 21/2* 2.875 2.468 100 11 5.80 lbs/ft 7.875 30 3500 J[3068 j 00J 17 58lb/ j0 783J ci9 4* 4.500 4.626 1 00 1O80 lbs/ft J 16316 19 *Only available in Casa Grande. AZ **Corrosion Resistance Ratio per latest ui Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas,D( Masury, OH BuuMsrBcaripajw 63017 Bull Moose Tube's® Eddythread 40® is a lightweight replacement for Schedule 40 that has a Corrosion Resistance Ratio of 1. r c®us LISTED <9> 7 APPROVED [;] AD ON L..!!PAI ADVANTAGES OF BULL MOOSE TUBE® EDDYTHREAD 40® Has a Corrosion Resistance Ratio of 1.0. Has a pressure rating of 300 psi. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDYTHREAD 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB./FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 rll/4JL-1650 T 1418 j1 00 Ji 2070 1 2754 51 1-1/2 1.900 1.654 1.00 2.547 3 468 44 4.842 - *Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, TX Masur0H øuuoasuecr*tpr,w 63017 5 L c®us LISTED APPROVED no A.,-, ONFSA r Am.Scm. Fir. lM Sprir.iM.00*Un ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 617 364J61 J 1-1/2 1.900 1.712 0 12 _4'.53 -1.967 2.965 61 [iziiL Th16 [431j 2.JJr___230 L *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grand AZ Dallas, DC Masurt OH EU 005V CMUDANY 63017 Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM Al 35 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. r c@us LISTED I APPROVED [] AtONFSA (nIFPX Sprh*I., ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD Il® MIC preventative coating. NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER FT. Wt SIZE 1-1/4 4 1.660 1 .530 1.98 1.222 2.019 61 1/2 i9O0 1728 344 1844 2860 E 611 2 2375 2203 278 2330 3.982 37 21/2 4 28757 2705 166 r 2809 5299 30 : 3 3.500 il 3.334 100 3361 7.144 19 [ 4. WO 100 9 J[ 1i29j __19 _j *Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa GrandAZ Dallas 1X Masury, OH Buuoa,jBoroIpj,,y 63017 7 Bull Moose Tube's® Eddy Flow® is a specially engineered replacement for Schedule 10, offering better flow characteristics - I while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's® larger ID provides an opportunity for downsizing and further cost savings. Bull Moose Tube's® Ultra Eddy® is a versatile product that can be roll grooved welded and used with Pressfit* Products. ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® Certified to ASIM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry; preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 868 1.359 91 i546 l40 1107 1 920 ir 11/2 1.900 1 786 111 1.274 2.360 61 j2jT 2375 j[Tbo JL_1 6O4 IL334 _L 37 Pressfit is a Registered Trademark of Victaulic Company of America Corrosion Resistance Ratio per latest UI Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q ® For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grand AZ Dallas, X Masur OH UUMOOSE7UCENIPANY 63017 c®us LISTED <> APPROVED NMI ONM NFPA Ei NIPS (IN) 1 1-114 1-1/2 2 2-1/2 3 4 c®us LISTED APPROVBJ no L4ONFSA A medoaft Pitt ruFPA 1.315 1.660 1.900 2.375 I:LD(n)J 1 201 1.546 1.786 2.261 ULTRA EDDY8 FEiRkt 0868 1107 1 274 1 604 hi(jb/ft)] teAHedWeight(lb/ftJ 1.359 - 1.920 2.360 3.344 217 - 140 111 100 - - -- rThD Jj 1r1660 1[ '[ 350O 90j [16 EDDY FLOW fl22211 844 '[2 330' 2 8091r3 361[4 968T ]fl2 019j2 86O[982 5299 [7 144flL11290 L CRR ]L i198 1qo ioo] [oo (in)J 1.3"15 1 660 1 900 2375 2875 - 3.500-----'-- 4.560 1,09 - 7 1.442 1.682 - 2.157 2.635 3.260 4.260 __LmptyAei (1111 _9 SCHEDULE 410 1 2090 2640 3530 4340 5620 1 810 [water -Filled weighi(ib/ft)i 1.820 2.518 3.053 4.223 5.893 7.957 11.796 C.R.R. 1527 991 776 627 492 354 250 [0D(in) 1.3157 1660 1900 JL 2375 [DOn)fli137 T-4482---,-i7i 177 EDDYLITP LEptyNeghtOb/ft)J J 9JL 1 JL 967 Water filled Weight (thIft) 1 700 23 [29 j4 230 j r 11-T__T][IIIJ CRR O16 [ 1295 1650 1900 2.375 - - - EDDYTHREAD 1083 1418 1645 2123 4® LI 61 2.070 2.547 3.308 [Water-Rfled Weight (lb/ft)1 1.860 2.754 3.468 4.842 - L C.R.R.1 1.00 -.1..00 1.00 1.00 Don)LJ3157 1660 1900 23752875iL3500[ 4500 [ ID (in) ]fl049 i380 1610 r 2067 2469k 3068 1 4.026 SCHEDULE [Empty Weight ab_j, 1680 2.270_,, .720 ijf 3.660 580O 7.580 10.800 erAHWeight(lb/ 2055 2918 360r 5114 7875 1O783 16.316 [ C.R.R. 1.00 ' 100 1.00 1.0O 1.00 :1.00 1.00 A For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande.AZ Dallas, X Masur OH UU.MQDSE1UBECOM02A1t1Y 63017 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE c®us LISTED APPROVED (] z4 ONFSA NFPA ULTRAEDDYJ 0.868, 91 1,659 1,896 1,975 I.410 SCHEDULE 10 1 91 2 695 3,079 *3 208 EDDYLITE® 1.260 91 L 2408 - 2,752'-2867T EDDYTHREAD4O® 1461 70 2 148 - 2454 2,55i SCHEDULE40 1.680 70 2470 2822 2,940 ULTRA EDDY 1.107 *_1[ 688 EDDY FLOW 1.222 6i1Ii565 =1'864' SCHEDULE 10 1.810 61 f2 319 650Tr27601 EDDYLITE 1617 [61 JL2 071 j2367j[_ 2466 EDDYTHREAD4O® 2070 5i Jr2217 1r 253 *]r26391 SCHEDULE40 2270 51 43 IL ?ZZ ULTRA EDDY® 1.274 61 1 632 1 865 1 943 EDDY FLOW® 1.844 61 2,362 2,700 .2 ,812 SCHEDULE10 2.090 61 2,677 3,060 3,187 EDDYLITE® 1 967 61 2 520 2,880 3,000 E6DYTHREAD4O®J 2.547 44 2353 2,690 2,802 SCHEDULE 40 1 2720 44 2,513 2,872 2992 *J E T.I1T1 L..J TiETI1 i;i ][2o69[2i5s* jr_37_iL i? 4?::J ETTL__37 iET23 JL2a fl 33 1r3° L_3660.. r 30J 1r 2 ô84 ]fl2382 ....... ....... 2481fl 2306J2635j2745j 2.809 ,. 1,770 2,022 2,107 3.530 30 2,224 2,542 2,648 5800 3,654 4,176 4,350 [361 ii341L 15 t159 19 1,979 ___:1_2,062 7580 .1 - 3024_fl56 3601 4.968 1,982 -- 2,265 2,360 5.620, 19 2,242 2,563 2,670 10.800 4,309 .. 4,925 5,130 9289 1 - 1L19 51 I2iIiI22I 16.940 7 2,490 2,846 2,965 10 * Only Available in Casa Grande. AZ. BULL. MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & Co for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace spacing* Size 20 ft. F25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 1/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1 1/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 1751 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 1 40 40 40 36 32 30 28 26 25 24 23 3 809 648 1 531 455 381 40 40 1 40 40 37 1 34 31 1 29 28 26 1 25 1 24 4 1 1544 1 1235 1 1012 867 726 40 40 40 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. F25ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 1 1/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 1 1/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 C c®us LISTED <> APPROVED (] £Qt4L NFPA' QD For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ DallasD( Masurt 01-I 63017 11 Mechanical-I® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a 1-olefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve across connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500p5i/345OkPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Tic-Tap III hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPOM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "V nitrite Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air With oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect_ Para_________ Location Date Approved Date____________________________________ www.victaulic.com Ac- viclAuLic ISA REGISTERED TRADEMARK OF ICTALIC COMPANY. 2017 VITAULI COMPANY. ALL RIGHTS RESERVED. ___ts _______ U1 ii ice REV_N 11.02_1 DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Size No. ~Pr~essure@ 1,I,canac,ul. Weight': 4 .. "' 150 2.00 2.53 1.61 5.35 275 3.1 2 ½ (a) 92014 500 50 15 3450 - 38.1 51 64 41 136 70 1.5 - 34(a) ° 92014 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 15 - 1(a)" 92014 500 1.50 1.85 2.53 1,61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 - 11/4 (a) to 92014 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1½ (a) I'D 920N 500 1.75 2.03 2,75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 1 83 1.7 1.5 21/2 x ½ (a) " 92014 500 1.50 2.21 2.74 1.82 564 2.75 3.0 65 15 3450 38.1 56 70 " 46 143 70 1.4 - 1/4 a) § " 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 - 1(a) §a 920N 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 - 46 143 70 1.4 - 1¼ t (a) U 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 11/2 t () 0 92014 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 761 x 1h (a) 92014 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 - 57 164 81 - 1.8 34(a) 92014 300 1.50 2,19 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 57 164 81 1.8 - 1(a) 92014 300 1.50 2.07 2.75 2.25 6.46 3.18 3.8 - 25 2065 38.1 53 70 - 57 164 81 1.7 11/4 (a) a92014 500 1,75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1h (a) a920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 x 1/5 (a) a 92014 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 - 34 (a) a 92014 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 - 58 156 70 1.6 1(a) 92014 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 - 58 156 70 1.6 - 1¼ (a) tD 92014 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 1 1.8 1.8 11/2 (a) to 92014 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) 92014 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 31/2 2 92014 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 >< 90 50 - 3450 63.5 76 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 4# Female threaded outlets are available to NPT and BSPT specifications. See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21,T BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com Aic-ta-ulicr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERvED. 11.022 REV_N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psiI3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 'H/50 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N en.. ,. Weight ach TABLE CONTINUED FROM PAGE 2 4 X 1/5 (a) u 920N 500 1.50 303 3.56 1 269 ( 7.01 2.75 37 100 15 -3450 J J! 11 L JZL 2L JL 34 (a) D 920N 500 1.50 3.00 356 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 1.8 - 1(a) U 500 1.50 288 920½ 3.56 2.69 7.01 2.75 3.6 25 34501 38.1 73 90 - 68 178 70 1.8 - 1 4 (a) tU 920 N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 1 44.5 78 96 102 68 178 76 1.9 1.8 IA (a) f3 2 500 2.00 3.28 9 ON 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) tU 50 920N 500 2.50 3.25 3450 63.5 83 4.00 102 4.00 102 2.69 68 7.01 178 3.88 99 5.0 2.3 4.6 2.1 21h (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 .JL. 500 2.75 2.88 ..102 102 4.00 68 2.69 186 7.34 118 4.63 2. 6.4 761 mm 920 69.9 23 ..3450 J1, JL 68 186 ..118.. 3(a)t 920 500 350 331 450 412 269 773 512 84 64 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 108.0 x 1 ¼ (8( 6 2 500 1.75 3.08 9 0N 3.78 2.63 7.64 3.05 5.0 32. 3450 44.5 78 96 - 67 194 78 2.3 - 11/2 (a(u 920½ 500 2.00 3.28 4.00 - 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 67 194 83 2.3 2 (a) 50 920½ 500 2.50 3.25 3450 63.5 83 4.00 102 - 2.63 67 7.64 194 4.00 102 4.0 1.9 - 761 mm 920 500 2.75 1 2.88 4.00 4.00 2.63 7.64 4.29 8.0 1 7.8 3450 69.9 73 102 102 67 194 109 3.6 3.5 3 (a) 920 500 1 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 -3450 1 88.9 84 114 114 67 194 124 3.1 30 5 1 ½ (a) 2 500 2.00 4.03 920 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 1 94 3.4 3.4 2 (a) t 500 2.50 4.00 920 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 1 63.5 102 121 121 80 246 III 3.7 3.6 21h (a) t 500 2.75 3,63 920 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 1 3.6 76.1 mm 500 2.75 3.75 92 0 3450 1 69.9 95 - 4.75 121 3.16 80 9.70 246 4.63 118 - 8.0 3.6 3(a) t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 1 3.8 4.0 1 330 2 , x 920½ 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 . 50 3450 63.5 95 114 - 81 203 920 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 3450 88.9 97 127 - 76 240 135 3.6 TABLE CONTINUED ON PG 4 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 211Y BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com A-c-ta-ulie vicTAuLic IS A REGISTERED TRADEMARK OF vIclAuLic COMPANY. 0 2017 vicrAuLic COMPANY. ALL RIGHTS RtSERvED. REV...N 11.023 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. si~e Style Ek Approx. No. Dimensions Weight Each 10. Z] TABLE CONTINUED FROM PAGE 3 1397 x 1½t 920N 500 2.00 I 3.78 1 4.50 3.30 8.23 3.25 1 7.0 40 3450 50.8 96 114 - 84 209 83 3.2 - 2 t 920N 500 2.50 375 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 84 209 99 4.1 - 6 x 1¼ (a) 20N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 32(b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 1'/2 (3) to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) fa 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 1 2.5 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 2½ 65 3450 1 69.9 . 110 130 130 94 267 118 3.8 3.4 761 mm n 90 2 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 132 94 267 118 - 3.8 3(a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6,25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 59.0 x 11/2(3) 9 0 2 N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 - 92 239 83 3.5 - 2 (a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 - 92 239 99 3.6 - 76.1 mm 20 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.0mm 920 500 4.50 4.45 5.38 3.63 9.4 0 6.12 10.0 3450 114.3 113 - 137 92 239 155 - 4.5 2 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 114.3 96.80 146 - 92 1 239 159 8.2 - TABLE CONTINUED ON PG. 5 -71 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. $ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.Com vicrAuLic IS A REGISTERED TRADEMARK OF VICTAC COMPANY. © 2317 vicTAuLic COMPANY. ALL RIGHTS RESERVED. X0 4-C -ts - U1 ii e 11.02_4 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½"I50 x 15mm through 8 x 47200 x 100 mm JIlIL.lIW•lL 1, . ~ ENC--) [FIT TABLE CONTINUED FROM PAGE 4 1651 X 1 920N . 500 1.50 3.88 456 379 934 2.75 30 25 3450 381 99 116 - 96 1 237 70 3.6 - 32 920N 500 75 4.43 3450 1 445 1 113 513 130 379 9.34 325 - 96 237 83 8.4 38 - 1½ (a) 920N 500 200 441 5.13 513 379 934 325 84 54 40 3450 30.8 112 130 130 96 1 237 83 38 2.4 2 @11 °20N 500 2.50 438 5.13 5.13 3.79 934 388 8.5 6.0 50 3450 63.5 111 130 1 130 96 237 99 39 2.7 761 mm 920 500 275 4.01 3450 659 110 5.13 130 5.21 3.63 10.51 463 132 92 267 118 8.6 39 76 34 (a)to 80 920 500 3.50 4.31 5.50 5.13 363 10.51 5.31 102 8.4 3453 889 110 140 130 92 267 135 4.6 38 ,j Ir 100 920 500 450 381 3450 1143 97 5.75 146 538 3.63 10.51 6.25 137 92 267 itS 105 4.8 8.4 3.8 200 50 920 500 275 5.44 3450 699 138 619 157 625 4.81 1242 4.50 159 122 316 114 11.6 53 11.6 5.3 1h (a) 500 275 1 5.07 920 3450 69.9I 29 619 157 619 4.81 1242 4.50 157 122i 316 114 11.6 53 116 5.3 - ,.1 mn 500 2.75 5.25 920 3450 69.9 133 625 4.81 1242 456 159 1 122 316 116 116 5.3 a) to 530 3.50 5.31 920 650 6.50 1 4.81 1247 531 12.6 11.6 80 4(a) to 3450 88.9 135 500 4.50 481 165 6.75 165 122 316 135 6.38 481 12.42 625 5.7 153 5.3 125 100 3450 1143 122 171 162 122 316 159 69 1 57 center at run to engaged pipe end, temale threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 41 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victauliC.Com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_N AC-ta uI i c 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°FI+16°C are shown in the table below. Exaggerated for clarity Formulas for C,K. Values: 51D = Q1 Where: Q = Flow (GPM) AP = Pressure Drop (psi) Q = C x C= Flow Coefficient AP = Where: Q = Flow (m5/hr) AP = Pressure Drop (Bar) Q = ç, x /A-P /A—P KV = Flow Coefficient Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe OUTLET SIZE ½ II CC 1201t FT C,/K~ Values lu1.I•St) G:8a.s83 I i3l1.A II !tI)i 0.840 11 15 21.3 2 - SA - Y4 1.050 16 20 26.7 - - 13.7 1 1.315 21 25 337 3 8. - 1.8 iv 1.660 6 50 48 32 42.7 5½ 42.9 41.1 114, 1.900 53 .53 40 98.3 11 11 45.4 45.4 2 2.375 112 104 50 . 60.3 10 V'2 96 89.1 2½ 2.875 119 150 65 73.0 20 12½ 102 128.5 761 mm ] 3.000 161 1 - 76.1 138.1 3 3.500 249 - 237 80 88.9 14 213.4 203.1 1 4.500 * 421 1 401 100 j 114.3 20 22 360.8 1 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165irsi4.2mm. 1 FireLock Innovative Groove System (IGS) outlet www.victaulic.com J' ____________tauIic VICTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. ____ 11.02_6 REV_N CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Pipe Approval Agency Rated Working Pressures — psi/kPa L _____ -i Liiç II 21/2-6 2875- 6.625 All 10 40 400 400 400 290 232 362 65-150 73.0-168.3 __________ 2755 2755 2735 1999 1599 2496 21/2 -4 2.875 - 4.500 All OF 300 300 300 290 232 362 65 100 730-1143 __________ ___ 2065 2065 2065 1999 1599 2496 21/2-4 2.875 - 4.500 All SF 300 300 300 290 232 362 65-100 730-1143 1 2065 2065 2065 1999 1599 2496 6 6.625 10 300 300 250 290 232 362 150 168.3 - 2065 2065 1724 1999 1599 2496 6 6.625 34 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 - - - 145 - 200 219.1 2755 1000 8 8.625 34 300 - 250 - 145 200 8 219.1 8.625 ' 2065 1724 1000 - 34 3040 300 - 300 - 145 200 219.1 ' 2065 2065 1000 - NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. OF refers to Listed/Approved Dyne-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 8/100 - 200MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5/125mm, 6/150mm and 8/200 mm diameter pipe. The Style 931 comes with a 2W/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF viclAuLic COMPANY. © 2017 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV_N \1 -C ta uIc r 11.02_7 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV N UPDATED 12/2017 vIcTAuuC IS A REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. C 2017 vlcTAuuc COMPANY. ALL RIGHTS RESERVED. X, Ac--ts - U1 ii ice 1L02_L STYLE 922 The Style 922 outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are ULIULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2005 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G \JtauIid 10.52_i DIMENSIONS IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-I STYLE 922 No minal Size mche St.. Hole Diameter 1 30.2 Approx. 1flflr.rnhr ThIITiTh1, We ight Each 1.30 1.83 1.10 1 3.87 2.56 1.0 33.0 46.5 27.9 98.3 65.0 0.45 1 ¼ 1/2 32 15 34 1 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 °46 1.52 2.18 1.10 3.87 2.56 . 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ 1h 40 15 1°/, 30.2 1.42 1.95 36.1 49.5 1.22 4.08 31,0 103.6 2.56 65.0 1.2 0.54 3/4 13/161.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31,0 103.6 65.0 0.54 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 ½ 13/16 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 1 116.8 65.0 0.59 34 20 1 1/16 30.2 1.64 1 2.19 41.7 55.6 1.46 1 1 4.60 37.1 1 116,8 2.56 65.0 1.4 0.64 1 25 13/16 30.2 1.88 2.54 47.8 64.5 1.46 4.60 37.1 116.8 2.56 65.0 1.5 1 0.68 2½' ' ½ 13A 1.91 2.44 1.71 5.40 2.56 1.6 65 '. 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 34 20 13/16 30.2 1.89 2.44 48.0 62.0 1.71 5.40 43.4 137.2 2.56 65.0 1.6 0.73 1 1'/16 2.13 2.79 1,71 5.40 2.56 1.6 25 30.2 54.1 1 70.9 43.4 1372 65.0 0.73 ½ 76.1 mm X 13/16 1.91 1 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43,4 139.7 65.0 0.73 3/~' 1 1.89 2.44 ' 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 '1 1 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43,4 1 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NOT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NOT threads (dimensions are approximate). wwwvictauIic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.522 \4taulic' REVG IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 PERFORMANCE Run Size x Outlet Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 10 (C=120)*, FT Fi!ers_ 25 I 32 I. 8.5 I C Hazen-Williams coefficient of friction is 120 FireLock® Outlet-T STYLE 922 www.victautic.com \JtauIic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ______________ REVG 10.523 STYLE 922 INSTALLATION Reference should always be made to the I-lOU Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com A-C--taulid 10.52 3355 REV G UPDATED 12/2009 vIclAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 luctile Iron Threaded Fittinc .... I 1. 0-mm 2. SMTHCOOPER® INTERNATIONAL Ductile Iron Threaded Fittings rSpeciflcations - I branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP u Ductile iron castings conform to ASTM A536 c ® L us LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 < FM > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME 131.2.0.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 120 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 _1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.61 30 60 0.7 1-1/2x1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35AE3014006 - 1.523 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 _2x1 1/4 35RE3020012 190 210 12 24 13 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F3 _450 Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25: 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 COUS APPROVED Fig. 35E 3_900 Elbow LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 1-40 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 3513006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T3020 2.25 6 12 2.4 2-1/2 3513024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com Size in Part Number A in B in C in Pack1_ Weight lb Inner Master 314x1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 X1 35RT3010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35R13010004010 1.50 1.36 1.50 30 60 0.6 1 x3f4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1x3/4x3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35RT3010006010 7 T5o 145 150 25 50 07 1-1/4x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1j3/4x11/4 35RT3012006012 1.7,5 1.62 :1 75 20 40 1.0 1-1/4x1 35RT30120-lo 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35R13012010004 1.34 1.26 50 0.7 1-1/4 x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x lxi 1-1/4x1x1 1/4 35R13012010010 35R13012010012 1.58 1.75 1.50 1.69 1.69 1.75 20 15 40 30 0.9 1.0 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-112x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 11/2x1/2x11/2 1-1/2x3/4 1-1/2x3/4x-1/4 35R13014004014 35RT3014006 194 166 194 12 24 12 1.52 1.52 1.75 16 32 1.1 35RT3014006012 194 1.66 1.88 20 40 1.1 l-1/2x3/4x1-1/2 35R13014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35R13014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35R13014010010 1.65 1.50 1.80 16 32 1.0 1-112x 1 x 1-1/4 35R13014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35R13014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-114 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x 1-1/4 x3/4 35R13014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35R13014012010 1.65 1.58 1.80 16 32 1.1 11-1/2x1-1/4x1-l/4 35R13014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35R13014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 I 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35R13020010020 2.25 2.02 2.25 8 16 1.9 2x1 1/4 35RT3020012 190 190 210 8 16 19 2x1-1/4x2 35R13020012020 2.25 2.10 2.25 8 16 2.0 2x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35R13020014010 1.73 1.65 2.02 8 16 1.5 2x11/2x1-l/4 35R13020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-l/2 35R13020014014 2.02 1 1.94 2.16 8 16 1.8 J 0 C us APPRED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number ____ A in B in C in Packg Weight lb Inner Master 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 .1-1/4xixl-1/2 358T3012010014 1.88 1.80 1.82 15 30 1.2 l-1/4x1-1/2 35B13012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35813012020 2 10 2.10 190 10 20 1.6 1-1/2x1-1/4x2 358T3014012020 2.16 2.10 2.02 10 20 1.8 1 1-1/2x2 35813014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com 112 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x314 35H83010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2x1 35HB3020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2x1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 - Square Head Plug I Size I in Part Number A in Packing Weight lb Inner Master I 1/2 35SP3004 0.94 600 1200 0.07 I3/435SP3006 1.12 350 700 0.1 I 1 35SP3010 1.25 200 400 0.1 I_1-1/4 35SP3012 1.37 100 200 0.3 I_1-1/2 35SP3014 1.44 80 - 160 0.4 I_2 35SP3020 1.50 45 90 0.6 I c®uS <~> OVED A Fig. 3503 - Straight Coupling with Ribs LISTED I I Size in Part Number A in Packing Weight lb Inner Master I 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 14/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 - 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A 1 i n Packing Weight Inner lb Master 1 x 1/2 35RC3010004 1.69 80 160 0.3 1x3/4 35RC3010006 1.691 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 I 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 - 40 1.0 Fig. 35HB3 -Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number ___ A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U3012 2.50_ 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 1 3.12 1 6 12 1 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com y74f A A c®uS <e> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 225 6 12 28 Fig. 3513- Cross Fig. 35R13 - Reducing Cross Size in Part Number A in B in Packing Weight lb Inner Master 1-1/4x1 35RX3012010 1.67 1.58 15 30 1.2 11/2x1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C06 0.97 200 400 .1 1 35C3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BCS - Beam Clamp Size in Part Number A in Packing Weight lb Inner Master 3/8 35BC3003 0.75 100 200 0.3 112 35BC3004 0.75 80 160 0.5 -;- L SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 8904456 0 www.smithcooper.com 114 jTAIoNsTEP 000D&TEEL. Insert the appropriate nut driver into a 3/8"or 1/2 " portable drill. Insert the SAMMYS® into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver light to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 114",3/8', 112' or metric all thread rod, bolt stock. (The 1/2"requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8"or 117 portable drill. Insert the SAMMYS into the #14SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4', 3/8", M10, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INNER 1 10, -- amn-K] IBM I IN iP p,14TE: I Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2' with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit slould remain in the drill), and insert the #14 (black) nut driver (p/n 813910) into the opposite end (see Vertical Installation note above). Insert the CSTs.rew into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock. (#14SWred nut driver used with 1/2"screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw Using an SDS 250 carbide tip bit ova HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre -drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14SW (red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8"or metric all thread rod or bolt stock Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. ii1lliil1ulliiNlHj& SPECIAL. NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe Installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. no p - 1/4" 8024957 DSTR 100 • 1/4-20 x TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" -- 25 125 1/4 8025957 DST 100 1/4_14 xl_TEKS 3 446(209a) _03620 ga 3/16 25125 1 114" 8026957 DST 150 114-14 a 1-1/2" TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 _1/4_8027957 DST 200 1/4_14x2_TEKS3 446 (20ga) 036_20ga 3/16 25125 1 1/4 8030957 TEK 500 12-24 x 1-1/2* TEKS 5 3125 (3/16") .188-3/16 1/2' 25 125 [.>3/88038957DSTR I _1/420 xl_TEKS 31510(20 ga) 1500 _1475 036 20 ga3/16" 71 .. <> 3/8' 8037957 DSTR 1-1/2 * 12-24 a 1-1/2' TEKS 5 1510 (3116') 1500 1475 060'-16 ga. 1/2" 25 125 EIK-3)88039957DSTR 5165/16_18 x 11141EKS32200(209a)15001475 _036_20g 3/!6 25 125] 3/8" 3/8" 8040957 5 8041957 DST 10 DST lS1/4-l4xl DST 15 114-14x1"TEKS3 1/4-14 x 1-1/2' TEKS 446 (20 446 (20 TEKS 3 03620ga3l16 .036'-20 ga .036'-20 ga 3/16" 3/16" 25 125 25 125 3/8 8078925 DST 15 SS 1/4-14 a 11/2 TEKS 3 446 (20 .036-20 ga 3/16 25 125 3/6" 8042957 DST 20 1/4-14x2'TEKS3 446 (20 .036'-20 ga 3/16" 25 125 3/8' 8043957 DST 25 1/4-14x2-1/2'TEKS3 446 (20 .036"-20 ga 3)16" 25 125] 3/8" 8044957 DST 30 1/4-14 a 3" TEKS 446 (20 .036-20 ga 3/16' 25 125 [_<3I88o45957 DST 5165/16-18x1-1/4' TEKS a 1500 (3/16')15001475.125-1/8"3/W25125] 4.8> 3/8" 8040957 TEKSO 12-24x1-1/2'TEKS5 3125 (3/16") 1500 1475 .250"-1/4" 1/2' 25 125 1)2" 8031925 DST 2.0 1/4-14x2 TEKS 3 446 (20 .188-3/16 1/4' 25 125 1/2'8033925DSTR1.0"1/4-20 xl" TEKS31510(20 ga.) .036"-20 ga Will" 25125 [•• _1/2"8034925DSTR5.16 _5/16-18x1-1/4 TEKS32220 (20ga.) 036'-20ga 3/1&25125 1 1/2' 8035925 DST 5.16 5/16-18 x 1-1/4'TEKS 3 1500 (3116") .125-1/8" 3/16" 25 125 8036925TEKSO1224x11/2_TEKS53125(3/16) 188-3/161/225 125] 'Includes retaining nut #14 Black Nut Driver Part # 8113910 1- #14 SW Red Nut Driver Part 8 8114910 SAMMYS FOR STEEL SAMMYSO FOR STEEL - Vertical Application Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Made in the U.S.A. 6121 hevJao no dnsbw na1 ww'.w.ft,ibuildexcom () Y SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are Installing into, continue drilling until nut driver spins OEM= free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 6~Affmyg ________________11rocitcrI*1tIIt"4 "Made with TOO self-drilling fasteners -no pre-drilling required. 4 n o Installs into steel range from 20 gauge - 1/2" thicknesses. m1e - fl "A standard screwgun with a depth sensitive nosepiece should be used to c ed install Teks. For optimal fastener performance, the screwgun should be a r minimum of 6 amps and have an RPM range of 0-2500. -- Saves time from traditional methods. "Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. Made in the U.S.A. Piwftwbuildex.comJ Approvals Rod Size Part Model Number Screw Descriptions Ultimate UL Test FM Test Min Max Pullout (lbs) Load (lbs) Load (lbs) Thickness Thickness Box Qty Case Oty -1/4" 8047957 SWD 100 1/4.14 xr TEKS 3 1477 (16 ga.) 060-16 ga 3/16" 25 125 8049957 SWDRIOO 1/4-20x1"TEKS 3 1900 (20 ga.) .036-20 ga 3/16" 25 125 1 3/8" 8050957 SWD 10 1/4-14 a? TEKS 3 1477 (16 ga.) 060"-16 ga 3/16" 25 125 3/& 8080925 SWD 10-SS 1!4-14x1"TEKS 3 1477 (16 a.) .060'-16 ga 3/16* 25 125 1 318" 8051957 SWD 15 114-14 a 1-112" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16 25 125 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477 (16ga.) .060"16ga 3/16" 25 12U - 3/8" 8053957 SWD 516 5/16-18x1-1/4TEKS3 2480 (20 ga.) .036-20ga 3/16" 25 125 3/8 8055957 SWDR 1 1/4-20 xl TEKS 3 1900 (209a) 1500 1475 036 20 ga3/16 25 1251 #14SWRed C> 3/8" 8054957 SWDR1-1/2 12-24x1-1/2"TEKS5 2375 (3116) 1500 1475 .188"-3!16" 1/2" 25 125 Nut Driver [<> 3/8" 8056957 SWDR516" 5/16-18x1-1/4"TEKS3 2480 (209a.) 1500 1475 .036-20 (la 3/16" 25 125 Part #8114910 - 3/8" 8057957 SWT15 12-24x1-1/2"TEKS5 2375(3/161 .188-3/16" 1/2" 25 125 includes retaining nut SAMMYS SWIVEL HEAD' FOR STEEL -Swivel Application ILW S A II/1M V X-PRESSO Installs into Metal Deck, Purlin, or Tubular Steel The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8"). Installs in seconds with Sammy X-Press Ite Tool, saving time & installation costs. 'Use in applications where access to the back of the installed fastener is prohibited. le. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. 'Made in the U.S.A. Waicha no,,s55105 at www.itwbuildex.com 1/4' 8181922 XP 200 X-Press 200 .. 9d 250 (Luminaire) Z6' .125" 25 125 Metal Deck 3/8' 8150922 XP 20 Sammy . 850(2WPipe) 1146 t22 a)185 (Luminaire) .027' 940 /475 (4 ON 194 25 25 125 Metal Deck X Press 20 250 (Lurrinaire) .056' 283 (Condu4&Cable).029" 029 1500(4' Pipe) .060" <> 3/8" 8153922 XP 35 Sammy 1783 '16 a' 185 (Luminaire) .029" 9.40 (2 Pipe).029"125" 25 125 Pullin - X-Press 35 250 (Luminaire) .056' 1475 (4" Pipe) 104 416 (Conduit & Cable) .059" Me - Pre-Pour Structural Concrete@ 3000 psi X-Press 20 25 125 (P-Pour) 8150922 XP 20 Samm 114o (22 ga) 850(2,6 Pipe) Post Pour Range II LWCo 35 PCF (lbs/f1) Metal Deck Pro-Pour Structural Concrete @3000 pal Post-Pour Range II LWCS 35 PCF (thai ft') Lr 'The SidewinderX-Press expands to provide 'Less jobsite material needed. horizontal attachment in: - 16 ga - 3/16" steel - purlin, tubular steel. No retaining nut required. 'Installs in seconds with Sammy X-Press ItO Tool, "Provides design flexibility. saving time & installation costs. 'Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited; Ia. metal roof deck, tubular steel, or vapor barrier fabric. t40xha*animat,utpJnot wwwIiwbuIIdex.comJ J& 3/8' 8293957 SWXP 35 Sidewinder X.Press35 1250 IV? Pipe) 1798 (16 go) 80 (Luminaire) .059" .125" 25 125 Pullin AIO S for L re'r1e or raflt ruOf p1tCh° F OWA I mi? MYSI The SwWeIX-Press allows you to hang plumb in extreme roof pitches: - 89° in z-putiin 45° in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press It5 Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsile material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. . Watch8ddeadn ?% - www.itwbulldex.com) 750 (2 Pipe) 110 Vertical (Luminaire) 4' ° 3/8' 8294922 SXP 20 O 10611 (22 a Vert) X-Press 20 829 (45* Off Vert) 80 @ 45° (Luminaire) .029" 635 (2 Pipe) .929" 125" 25 125 Metal Deck 283 Vertical (Conduit & Cable) 233 @45° (Conduit & Cable) 1250 (3-112" Pipe) vel 1675 (16 ga Vert) 250 Vertical (Luminaire) <> 3/8" 8295922 SXP 35 X-Press35 1558 Off Vert) 500 Vertical (Conduit & Cable) 635 (2" Pipe) .029' .125" 25 125 Pudin 333 @89° (Conduit & Cable) Swivel 1061 (22gaVert) 112' 8272957 SXP 2.0 X-Press2.0 829(45°OffVert) Swivel 1675(l6gaVert) 1/2" 8271957 SXP X-Preus 3.5 1558 (89° Oft Vert) .027' .125" .060" 125" 25 125 Metal Deck 25 125 Paths The Sammy X-Press expands to provide direct vertical attachment in: I •" I I ' - metal deck (22-16 gauge) jj \i j ""' 'N • gauge) Made in the U.S.A. 4 •- rwr,a at*o St,atu,a at 8152910 XPDB 25/64' Drill Bit *Tool Includes: Sleeve, Bit Receiver, Hex V*enck, and 25/641 Drill Bit. APPROVALS 8007957 GSTIO 3/8" Vertical .CPVCI-112" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST2O 3/8" Vertical 2-1/2" 850 1-1/2° 4" 1475 1-10 8068925 GST2O-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8109 T 30 318"...1Y!tL 8009925 GST25:380 3/8" Vertical 4" 1500 1-1/2" - 8022925 SWG25-380 3/8" Horizontal 3-1/2°-4"" 1500 1-1/2" 8021957 SWG2O 318" Horizontal 2-1/2°-3""° 1050 1-1/2" 8073925 SW 3/8 8269957 SH-GST/CST 20 3/8" 450 Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SHGST/CST2O 3/8 45AngleoffVertical 4 1500 8139957 SH-GST2O 3/8" 17° Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" 8038957 DSTR 1 3/8" Vertical 4° 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 1500 .035" 4" 1475 .105" 8039957 OSTRS1O 3/8 Vertical 4 1500 037 4 1475 105 8045957 DST 516 3/8" Vertical 4° 1500 .188" 4" 1475 .188" 8046957 TEK56 - 3/8 Vertical 4 1500 250 4 1475 188 A 8055957 SWOR1 3/8" Horizontal - 4" 1500 .037" 4" - 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR1 3/8" 17°ArigleoffVerticai 1500 35" 4" 1475 - .100"j 8268957 SH-TEK5O 3/8" Vertical 2-1/2" 850 - -------- 70 Angle offVertical _4 - 15010 .- -. -- -.. ----.- - 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 4 1475 125" 6946-2 - '9)CP2!... 750 2T 635 .029° J 8295922 SXP35 3/8" Verticalorupto89° 3-1/2" 1250 .060° 20 635 .029° 8293957 11WXP35 3/8" Horizont 3-1/2" 1250 .060" 8059957 CST 20 Vertical £. 175........300 8061957 SWC2O 3/8" Horizontal 4" 1475 3000 8150922 XP2O 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Ranae II LWC s 35 PCF (lbs/1131 185 250 185 250 185 250 .027° .035" .027" .035" .027" --.- J .027" .027" .060" .060" J .060" 8150922 XP 20 3/8" Vertical L .. 8153922 XP 35 3/8" Vertical I 8181922 XP 200 1/4" Vertical Vertical 170 45* . 80 Vertical 250 90°. 80 Horizontal 80 L . .. ............ 8294922 SXP 20 3/8" 8295922 SXP 35 . 3/8" 8293957 SWXP 35 3/8" - .-" -..-.- ............ - . -.-.-. .- 8153922 XP 35 3/8° Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit [ 8294922 SXP20 3/8 Vertical 283 027" Max4 trade size EMT RMC and MC & 5 trade size ngid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit r 8293957 SWXP35 - 3/8 Honzontal 500 060 Max4 trade size EMT&6tradeszeRMC 0G and ngid PVC condud 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat No. C-Z2000 Plenum Rated, Sheet Steel tGauges Complies wl NEC Standards L!g.._....- 22ga. 20ga. 18ga. till ga. 14ga. 1211/8 !I6 . Nominal Decimal Equivalent .030" .036° .046" .060" .075" .105" .125" .188" .250" "SWG25380Madmum pipe oiseiscamposite wood joist allowed byULis3-112 "SWO 25-380 Maximum pipe size In wood timber orjoist allowed by UL is 4" . Ut Ian N C SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2' UL and FM tests were performed in carnptanra with NFPA 13 Standards **SWG 20 Maximum olDe size in wood timber or idst allowed bv UL is 3' Fastening sigubernent 5times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done forz-puriin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-PressO was completed using (.030") or 22 gauge steel metal deck. Sammys Nut Drivers Special nut dnvers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit w.itwbuildex.com for our current Seismic product offening. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should betaken not lust for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pie-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model t Diameter HoleISize GST 2O .182" 1/8" GST 25-380 .280' 7132- SWG 20 .182" 1/8" SWG 25-380 .280" 7/32 To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com Ak ISO AS 001011! 530 CAStE 5010102 SASS ASISDA300IORFORSOIAOS IO2 Technical Drawings Technical drawings are available and can be downloaded atwww.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made In the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUIILDEX Option #1 Mechanical Anchoring Systems I . . -... . KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. 3,3.73.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of AOl 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listinqs/Aoorovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor LLA&SPBS <g> APPROVE Independent code evaluation IBC®/ IRC®2015 IBC®/ IRC® 2012 IBC®/ IRC® 2009 IBC®/ IRC® 2006 Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilt (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 Mechanical Anchoring Systems Tjj 33.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter db.0 in. 1/4 Nominal embedment h0,,, in. 1-5/8 2-1/2 Effective embedment h1 in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T. ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 T0 is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 2,3,4,5 Nominal Nominal Tenson - pN0 Shear - anchor embed. = 2,500 psi f' = 3,000 psi /C = 4,000 psi f = 6,000 psi /C 2,500 psi f' = 3,000 psi f = 4,000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1/4 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete 1.2,3,4,5 Nominal Nominal Tension - 4)N n Shear - anchor embed. f = 2,500 psi f',= 3,000 psi P = 4,000 psi f',= 6,000 psi f', =2,500 psi f' = 3,000 psi f' = 4,000 psi f',= 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 /4 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) 1 (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete Only. For lightweight concrete multiply design strength by X. as follows: for sand-lightweight, A = 0.68; for all-lightweight, A0 = 0.60 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - a , 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aN, = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile' Shear' Seismic shear' diameter thread diameter qV qv in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension 4N DA,ONfCOas noted in AC1318-14 Chapter 17. 4 Shear determined by static tests with OV. <0.64A,5 ,,e as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with 4PV a q 0.60 A..V faa as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-80C-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 idllJ _____ Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concret&'2 Edge distance in shear Spacing factor Edge distance Spacing factor II to and away Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear4 uncracked concrete 'AN fRN lAy 'NV fRy 'HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 (mm) (41) (64) (41) (64) 1 (41) (64) 1 (41) (64) (41) (64) (41) (64) 1.1/2 (38) 0.71 0.63 1 018 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a .f. E 4 (102) 1.00 0.85 _______ _______ 0.74 0.66 _______ 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 1 0.81 CO 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 g 5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 . 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 Ca 10 (254) 0.89 CL 11 (279) 0.93 12 (305) 0.97 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked cnntrt&'2 FA Edge distance in shear (Ito and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear4 cracked concrete f I N JAy I fRy 'HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 0 (mm) (41) (64) (4;) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.68 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 _______ _______ 0.74 0.66 _______ 0.93 _______ _______ 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 D) N) 5-1/2 (140)__ 0.98 _______ _______ 0.83 0.72 _______ _______ _______ 0.93 6 (152) 1.00 _______ 0.86 _______ 0.74 _______ _______ _______ 0.98 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 CO a 10 (254) 0.90 11 (279) 0.94 12 (305) 0.98 - 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To Optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, fAv assumes an influence of a nearby edge. If no edge exists, then JAy = IAN 4 Concrete thickness reduction factor in shear, I assumes an influence of a nearby edge. If no edge exists, then f = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of Section 3.3.6 to calculate permissable edge distance, Spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 Mechanical Anchoring Systems 33.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked Iiahtweiaht concrete over metal deck1,23,45,6,7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - Shear - 4V Tension - 4N Shear - anchor thread embed. f'= 3,000 psi f'= 4,000 psi f,= 3,000 psi f',= 4,000 psif= 3,000 p5 f',= 4,000 psi f= 3,000 psi f'= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0). (3.2) (2.7) (2.7) IJNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1/ ______ 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked Iiahtweiaht concrete over metal deck' 2,3,4,5,6,7,8 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - cpN Shear - pV Tension - (pN Shear - qv anchor thread embed. f'= 3,000 psi f= 4,000 psi 3,000 psi 4,000 psi f'= 3,000 psi 4,000 psi f= 3,000 psi f= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 1 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) / 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive Strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,so 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - 0.85 See Section 3.1.8.6 for additional information on seismic applications. - - 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies r — Mm. 3/4" 17 Oar • " - or normal-weight concrete flute CA DO CO Upper r%JIi L %•_ME -1/2" minimum L steel deck Lower Mm /2 ;nc or Flute edge (typical) flute — Mm. 12" (typical) (ridge) Min.1-11/4 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for prcfiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. H 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACt 355.2 for mechanical anchors and AC! 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous AC! 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile' Shear' Shear' diameter diameter N, V, in. (LING) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASO value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N, = A N 4, f R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with v, <A 4 0.6 f, R as noted in GSA A23.3.14 Annex D. 5 Seismic shear values determined by seismic shear tests with v < A 4 0.6 fWa R as noted in GSA A23.3.14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 M Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. d in. 1/46 (mm) (6.4) Effective embedment2 1.92 in. 1.18 (mm) (30) (49) Minimum nominal embedment2 h 60,,, in. 1-5/8 2-1/2 (mm) (41) (64) Minimum concrete thickness 4-1/8 h in. 3-1/4 min (mm) (83) (105) Critical edge distance c 66 in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance Sm1n,caC in. 1.5 (mm) (38) Minimum edge distance Cfl,jfl in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in 2 2-7/ 8 (mm) Minimum specified ultimate strength f uta psi 125,000 (N/mm2) (862) Effective tensile stress area A SN in 0.045 (mm2) (29.0) Steel embed, material resistance factor for reinfcrcement - 0.85 8.4.3 Resistance modification factor for tension, steel 'allure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 0.5.3 Factored steel resistance in tension N, lb 3, 370 D.6.1.2 (kN) (15.0) Factored steel resistance in shear V r lb 750 0.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V,eq (kN) (1.5) Factored steel resistance in shear V5 lb 725 0.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V,eq (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete k - 10 0.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k66r - 7 0.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 41. 14 - 1.0 D.6.2.6 Anchor category - - 1 D. 5.3 (c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R Condition B5 - 0.75 1.00 D. 5.3 (c) Factored pullout resistance in 20 MPa uncracked concrete6 N pruncr lb 665 1, 645 0.6.3.2 (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete6 N5,6, lb 340 815 D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete6 N lb 275 815 0.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. For all design cases, qJ65 = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k,) or uncracked concrete (k666,) must be used. For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryDut strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qj0 = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. - .--------- .., 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 Iii 1TIII Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.37 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in uncracked concrete' 2,3,4,5 Nominal __________ Tension - N Shear - V f = 20 MPa f' = 25 MPa f = 30 MPa f', = 40 MPa f' = 20 MPa f = 25 MPa f', = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 1 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure tel in cracked concrete' 2,3,4,5 Nominal Tension - N ___________ ___________ Shear - V f' = 20 MPa = 25 MPa f Ic = 30 MPa = 40 MPa f' = 20 MPa = 25 MPa f'c = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 1 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by Aa as follows: for sand-lightweight, AC = 0.68; for all-lightweight, A = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. 3.3.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanci 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2.3,4.5,6.7 H Installation in lower flute Installation inupper flute Nominal Tension - Nr Shear - V, Tension - Nr Shear - Vr Nominal internal Nominal anchor thread embed. f = 20 MPa f' = 30 MPa f' = 20 MPa f = 30 MPa f = 20 MPa I = 30 MPa f'c = 20 MPa = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck 12'34'5'6'78 N Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N ___________ ___________ Shear - V ___________ ___________ Tension - N Shear - V anchor thread embed. f' = 20 MPa = 30 MPa f = 20 MPa f = 30 MPa f = 20 MPa f = 30 MPa f. = 20 MPa f = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) See Section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h, (nominal embedment). Tabular value is for lightweight concrete and no additional reduction factor is needed. No additional reduction factors for spacing or edge distance need to be applied. Comparison of the tabular values to the steel strength is not necessary. Tabular values control. Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by = 0.75. For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/40 -5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Hanger rod size Nominal embedment in. FM tension test load lb pipe diameter in. 3/8-16 UNC 1-5/8 1,475 4 2-1/2 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en españoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ 0 allowable stress desian values for installations into hnllow tnr r-nnnrafa nnIc1,2 Hanger rod size Mm. effective embedment h f in. Allowable load' Ultimate load Tension lb Shear lb45 Tension lb Shear lb45 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 I he admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS—EZ I (KH-EZ I) in hollow core concrete 3.3.7 I 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information" Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 11/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 - 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1 -800-879-5000 I Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1/l6 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 1114 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 13'6 11/4 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 1114 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 314" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2' and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8' pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, soacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HOG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Component of State of California OSHPD Approved c us LISTEDSeismic Restraints System OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 $ CUSTOMER SERVICE • 800.786.5266 wiew.toko.com c®Us LISTED Fig. 25- Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Size Range - Secures 3/8" thru 7/8' rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Component of State of California OSHPD Approved c@ US USTED Seismic Restraints System Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number H Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1315 SAMPSON AVE. CORONA, CA 92819 PH: 951.131.5599. FAX: 951.131.0330 a. CUSTOMER SERVICE • 800.186.5266 www.tolco.com Fig. 2001 to 200-2 Fig. 200-21I2 to 200-8 AH LI Fig. 200 Fig. 200C Fig. 200F Fig. 200 - "Trimline" Adiustable Band Hanaer (Cooper B-Line Fia. 83170NA ®TDLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining Cooper B-Line Fig. B3170NFF Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2' (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. MaximUm Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Part No. 200_1/2 Pipe in. 1/2 Size (MM) (15) Rod Size 3/8"-16 A 31/8 (79.4) 2/8 B (66.7) Approx. .. 11 Wt./100 (5.0) 200-/4 3/4' (20) I8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) /8"-16 3/a" (85.7) 2/8" (66.7) 12 (5.5) 200-1/4 11/4" (32) /811-16 33/4" (94.0) 2/8" (73.0) 13 (59 200-1/2 11/2" (40) 1 3/8"-16 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 2" (50) /8"-16 41/2" (114.3) 3' (76.3) 15 (6.9) 200_2112 21/2" (65) I8"-16 5I8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 5/8" (149.1) 4° (101.6) 29 (13.3) 200_31/2 31/2" (90) /8"-16 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7/t" (187.3) 5' (127.0) 35 (16.0) 200-5 5' (125) /2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"_13 131/8" 1 (333.4) 8I4" (222.2) 136 (62.3) All dimensions in charts and on drawings are In Inches. Dimensions shown In parentheses are In millimeters unless otherwise specified. COO ER B-Line Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod ®TOLCO Size Range: c®US Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe LISTED Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: - (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design ' ---. - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. '•. - - Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) - B in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fl to 200-2 A Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1i 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Fig. 200_1/2. 200-/4 Maximum Temperature: 650°F (343°C) Fig. 200-21/2 to 200-8 Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts / f in place of a knurl nut. / f Order By Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0 Part No. 200M8-1/2 Pipe in. 1/2° Size (mnl) (15) M8 Rod Size : in. (MM) 31/8" (79.4) in. 2/8" (MM) (66.7) lbs. 11 Approx.}Wt./100 (kg) (5.0) 200M10-1/2 1/2° (15) M10 31/8" (79.4) 2/8° (66.7) 11 (5.0) 200M8-3M 3/4" (20) M8 31/8..(79.4) 21/2' (63.5) 11 (5.0) 200M10-3/4 /" (20) Mi0 31/8" (79.4) 21/2" (63.5) 11 (5.0) 2001Y18-1 1" (25) MS 3I8" (85.7) 2/8° (66.7) 12 (5.5) 200Mb-1 1° (25) M110 33/8" (85.7) 2/8° (66.7) 12 (5.5) 200M8-11/4 11/4" (32) MS 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M1O 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200M10-1112 11/2" (40) M10 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200M8-2 2" (50) M8 41/2" (114.3) 3° (76.3) 15 (6.9) 200M10-2 2" (50) Mi0 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-2112 21/2" (65) M10 5I8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-3112 31/2" (90) M1O 7 /8" (187.3) 5I4° (133.3) 34 (15.6) 200M-4 4" (100) MiO 7/" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4' (158.7) 66 (30.2) 200M-6 6" (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8" (200) M12 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown In parentheses are In millimeters unless otherwise specified. COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /'-16 or 1/2°..13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Part No. I 29 /816 ' • I II1I} I I I (21 8 200H-2-112 2' (50) 1/2L13 423/32' (119.8) 33/8' (85.7) 45 (20.4) 2001I_21/2_3/8 21/2" (65) /8"-16 5/1 " (134.9) 323/32° (94.4) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"..13 515/32" (138.9) 3 /8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) I8"-16 53/4" (146.0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"..13 5/8" (148.1) 331/32" (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8"-16 6/8" (174.6) 4 /16" (112.7) 76 (34.5) 200H-4-1/2 4° (100) 1/2"_13 1 71/32" (178.6) 419/32" (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOKER B-Line F P P I Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ" System Compatible Program* Certified to NSF/ANS/Std 61-G FRCV- ~- -Row. SYSTEM COMPAflBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicalon is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com I CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. © 2012 Fire Protection Products, Inc. FPPFi, LubeFit° are registered trademarks of Fire Protection Products, Inc. Nu FGG/BM/CZ", Blaze-Master®, FlowGuard Gold5 and Co,zan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. ppl Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in 'high speed' fabrication operations. pet' Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FBCV-. SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSFIEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep - covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIG 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com -I © 2012 Fire Protection Products, Inc. FPPI', LubeFit® are registered trademarks of Fire Protection Products, Inc. FBC", BlaseMastet®, RowGuard Go/cP and Co,zane are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. F P P I Description ThreadFit® CLEAR Thread Cuffing Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cuffing oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke F BC SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIUNSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: 5k." contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes anl seek medical attention. Ingestion: consult a physician immediately. Inhalation: mote affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for addi:ional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300. © 2013 Fire Protection Products, Inc. FPPP, ThreadFe are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A.