HomeMy WebLinkAbout2510 EL CAMINO REAL; ; AS060296; Permit11/15/24, 10:58 AM AS060296 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS060296 2510 EL CAMINO Job Address: Status: ISSUED REAL Permit Type: SPRINK Applied 12/21/2006 Parcel No: Approved: 12/26/2006 Lot #: 0 Reference No.: Issued: 12/26/2006 PC #: Inspector: Project Title: CVS PHARMACY T.I. FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: Owner: AZTEC FIRE PROTECTION 8109 COMMERCIAL STREET LA MESA, CA (619) 464-5625 Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 about:blank 1/1 -I- Mo6 o2_qc, lProducts FiTè &tqco Technical Services: Tel: (800) 3817-9312 / Fax: (800) 791-5500 Series TYB - 2.8, 56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage 1 General Description The Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in This data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plaits, etc. The recessed version of the Series TV-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10(1/2 inch NPT) or Style 40(3(4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) o recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilzed to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed thd standard corrosion tests of the appli- cable approval agencies, the testing is IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause hie sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TV-B Pendent Sprinkler can be obtained by utilizing the Series TV-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers JULY, 2004 TFPI5I TY1151 - Upright 2.8K, 1/2NPT 1Y1251 - Pendent 2.8K, 1/2'NPT TV3151 - Upright 5.6K, 112'NPT TY3251 - Pendent 5.6K, 1/2'NPT TY4151 - Upright 8.0K, 314"NPT TY4251 - Pendent 8.0K, 3/4'NPT TY4851 - Upright 8.0K, 1/2'NPT 1Y4951 - Pendent 8.0K, 1/2'NPT ESCUTCHEON PLATE SEATING SURFACE 2-1/4 (57,2 mm) 1-9/16" (39,7 mm) 1/20 ** NPT 7/16' 11,1 mm) IOMINAL MAKE-IN 2-3/16° (55,6 mm) 6* WRENC FLATS 1/2° NPT** Page 2 of 8 TFPI5I NOMINAL SSU MAKE-IN DEFLECTOR 1l!i%mm) : L ,Li_I DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY1 151) AND PENDENT (TV1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING ** NOMINAL SURFACE 1/2,, MAKE-IN NPT 23t16. \ A (55,6 mm) f (38,1 mm) SSP DEFLECTOR* 1---- 2-7/8° (73,0 mm) DIA, SSU * DEFLECTOR STYLE 10 RECESSED ESCUTCHEON PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY3151) AND PENDENT(TY3251) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT .-.-.. SSP* DEFLECTOR CROSS UPRIGHT SECTION WRENCI- FLATS TFPI5I Page 3 of 8 ESCUTCHEON 1/2' (12,7 mm) STYLE 40 PLATE SEATING ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR i 4~~ / 112' 1 2-5/16' (12,7 mm) NOMINAL I (58,7 mm) (39,7 mm) Hi 1-9/16' MAKE-IN 2-1/4' r 2 WRENC (57,2 mm) 3 FLATS SSP DEFLECTOR 2-7/8"(73,0 mm) DIA. -1 3/4' NPT ** I * PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Ejection orifice seat on frame. Screw Spring **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4 151) AND PENDENT (TY4251) SPRINKLERS 8. K-FACTOR, 3/4 INCH NPT ESCUTCHEON PLATE SEATING SURFACE _F_ ~ 2-1/4 (57,2 mm) 1-9/16" (39,7 mm) 1 - Frame 3 - Sealing 2 - Button Assembly 7/16' (11,1 mm) 1/2" ** NOMINAL MAKE-IN NPT 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. SSU * DEFLECTOR PENDENT 4 - Bulb 5 - Compression Screw FIGURE 4 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Page 4 of 8 TFPI5I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED I WHITE... POLYESTER LEAD I COATED WAX I COATED WAX OVER LEAD COATED 2.8 1/2° NPT PENDENT (TY1251) and UPRIGHT (TY115I) 135°F/57°C Orange 1,2,3 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/1 41 °C Blue 360°F/1 82°C Mauve 1,2 5.6 1/2° NPT PENDENT (TY3251) and UPRIGHT (TV3151) 135°F/57°C Orange 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 2867F/141°C Blue) 1*,2**, 5°° 1", 2°°, 3* 5* 360°F/1 82°C Mau N/A RECESSED PENDENT (TY3251)* Figure 4 135°F/57°C Orange 1,2, 3,4, 5 I I I I 1,2,4,5 I Green N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C 8.0 3/40 NPT PENDENT (TY4251) and UPRIGHT (TY4151) 135°F/57°C Orange 1,2,3,4, 5,6,7 1,2,5 1,2,3,5 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 3'*, 5 1°°, 2°°, 360°F/1 82°C Mauve N/A RECESSED PENDENT (TY4251)° Figure 5 135°F/57°C Orange 1, 2, 3,4, 5 N/A 155°F/68°C Red 1750F/79°C Yellow 200°F/93°C Green 8.0 1/2' NPT PENDENT (TY4951) and UPRIGHT (TY4851) 135°F/57°C Orange 1, 2, 3,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 1 286°F/141°C Blue 360-F/1 82°C Mauve NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k103). Approved by the City of New York under MEA 354-01 -E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. 150°F/66°C Maximum Ceiling Temperature. Frame and deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS TFPISI Page 5 of 8 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8 DIA. (73,0 mm) 3/4"(19,1 mm) 1/4 (6,4mm) 2-1/4' DIA. (57,2 mm) MOUNTING I Ar WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END 'B" USED FOR 3/4" NPT MODELS) FIGURE 7 W- TYPE 6 SPRINKLER WRENCH MOUNTING SURFACE CLOSURE SEES (3,2 mm) 1-1/4' (31,8 mm) 314' (19,1 mm) FIGURE 5 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4° DIA. I 1/4" (6,4 mm) (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE FITTING 1/8 3,2 mm) It // MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TV-B 13/16" (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 6 of 8 TFPI5I Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/ps11/2 (40,3 LPM/barll2) K = 5.6 GPM/psi112 (80,6 LPM/bar1/2) K = 8.0 GPM/psi112 (115,2 LPMIbar1I2) Temperature Ratings Refer to Table A Finishes Sprinkler: Reessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector ...........Copper Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TV-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360°F/1820C temperature ratings. A leak tight 1/2 inch NPTsprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TV-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W-Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. The Series TV-B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- TFPI5I Page 7 of 8 stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TV-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TV-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY I MADEJ1LLJEU OF ANY AND ALL IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- POSE. Page 8 of 8 TFPI5I P/N 57 - XXX - X - XXX I MODEL/SIN 1 7 3 9 7 6 8 I SPRINKLER I TEMPERATUF RATING 135 135°F/57°C 155 155°F/68°C 175 175°F179°C 200 200°F193°C 286 286°F/141°C 360 360°F1182°C - 530 2.8K UPRIGHT (112°NPT) TY1151 NATURAL BRASS 531 2.8K PENDENT(1/2°NPT) TY1251 * WHITE POLYESTER 570 5.6K UPRIGHT (1/2°NPT) TY3151 WHITE (RAL9010)* 571 5.6K PENDENT (1/2NPT) 1Y3251 CHROME PLATED 590 8.0K UPRIGHT (3/4NPT) TY4151 LEAD COATED 591 8.0K PENDENT (3/4NPT) 1Y4251 WAX COATED 286°F/141°C MAX. - 560 8.OK UPRIGHT (1/2°NPT) TY4851 1 WAX OVER LEAD 286°F/141°C MAX. 561 8.0K PENDENT (1/2°NPT) TY4951 * TABLE B Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TV-B PENDENT AND UPRIGHT SPRINKLERS Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TV-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table B). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2° (15 mm) Style 10 P Plated .........PIN 56-701-9-010 1/2' (IS mm) Style 10 White Color - Coated ...............PIN 56-701-4-010 1/2' (15 mm) Style 10 White RAL9010' .......P/N 56-701-3-010 1/2' (15 mm) Style 10 Brass Plated...........P/N 56.701-2-010 3/4° (20 mm) Style 40 Chrome Plated .........PIN 56-700-9-010 3/4' (20 mm) Style 40 White Color Coated ...............P/N 56-700-4-010 3/4° (20 mm) Style 40 White RAL9010° .......PIN 56-700.3-010 3/4' (20 mm) Style 40 Brass Plated...........P/N 56-700-2-010 * Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (Specify tem- perature rating) temperature rated Se- ries TV-B Sprinklers, P/N (specify). Black for 135°F ............P/N 56-065-1-135 Red for 155°F .............P/N 56-065-1-155 Yellow for 175°F .........PIN 56-065-1-175 Blue for 200°F and 286°F .................P/N 56-065-1-286 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200°F sprinklers, and, therefore, the 2860Fsprinkleris limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 150°F).