1891 RUTHERFORD RD; 150; FPC2017-0250; Permit
(7c ityof PIERM][T REPORT Carlsbad Etii 1HiIff Print Date: 09/26/2024 Permit No: FPC2017-0250 Job Address: 1891 RUTHERFORD RD, # 150, CARLSBAD, CA 92008-7327 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121203600 Track t: Applied: 08/25/2017 Valuation: $1,162,750.00 Lot #: Issued: 09/22/2017 Occupancy Group: Project #: Finaled Close Out: 04/06/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fieri, Dominic Plan Check #: Metz, Randall Wong, Cindy Project Title: Description: NAVIGATE BIOPHARMA -SPRINKLER (1 RISER, 538 HEADS) Applicant: FPContractor: INDUSTRIAL FIRE SPRINKLER CO INDUSTRIAL FIRE SPRINKLER CO INC STEVE SCOTT 3845 IMPERIAL AVE 3845 IMPERIAL AVE SAN DIEGO, CA 92113-1702 SAN DIEGO, CA 92113-1702 (619) 266-6030 (619) 266-6030 x107 FEE AMOUNT FIRE NFPA 13 System> 100 heads (includes 1 riser) $832.00 FIRE Plan Resub (3rd&Subsequent Submittal/hr) $132.00 Total Fees: $964.00 Total Payments To Date: $964.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov R Submittal Package Approval Sheet CONSTRUCTION Navigate BioPharma Lab/Office TI DPR Construction, A General Partnership 1891 Rutherford Road Project #: D1-A17018-00 Carlsbad, CA 92008 Tel: Fax: I DPR Construction, A General Partnership Architect (DPII CONSTRUCTION 1890 Rutherford Road Carlsbad, CA 92008 Phone: Fax: Reviewed for general conformance to the contract documents. This review does not relieve the subcontractor of the responsibility of making the work conforn to the contract requirements. The subcontractor is responsible for all dimensions, correct fabrication, and accurate fit with the work of other trades. Submittal No: 211300-01 DPR Project No: Di-Al 7018-00 Reviewed By: Andrew Childs Date: 08-18-2017 Prepared: Industrial Fire Sprinkler Co Inc ARC IT-CTS 4499 MWA RHd. SM. 30K. SA, O. CA 92123 NO EXCEPTIONS TAKEN r REJECTED REVISE AS NOTED r REVIEWED o REVISE AND RESUBMIT 0 FOR RECORD O SUBMIT SPECIFIED ITEM COMMENTS OR CORRECTIONS MADE ON THE SUBMITTAL OR SHOP DRAWINGS DURING THIS REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS. THIS PLAN CHECK IS ONLY FOR REVIEW OF GENERAL CONFORMANCE WITH DESIGN CONCEPT TO THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS. SELECTING FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION. COORDINATING CONTRACTORS WORE WITH THAT OF ALL OTHER TRADES AND PERFORMING CONTRACTORS WORK IN A SAFE AND SATISFACTORY MANNER, FPRAPROJECTNO.: 16110 SUBMITTAL NO.: 211300-1 Fire Sprinkler SPEC: 211350-1 Fire SDrinkler Structural REVIEWED BY: DenomD GATE: 8/18/2017 SUBMITTAL FOR STRUCTURAL REVIEW ONLY Consultant Consultant S xcscwis t048 0 rUfNiSH AS CCTED AJ8Mfl CIC ITEM Ll lv 1E5LMIT 1:1 C I 'vw v for ger1er(3t conformance MIfl To C .n:a / .a and general complionco with The tiJw A1WOC11H3fl 'irc Ti She requirements of the drGMngs r.nd Cc-ntfoctcx is responsible for: correlating and ccrr.r 1sat1e job site. choice offdcaTho1 p:':cO13. aT w;I.-o s of corsslructlon: c in c*x,, of l,v,'CH ;flt01 T.4IC: ticdr4: (Z'0Pfl1IiIQ it* IflO ce ana sc.oecc'ocy rnonner. WiSEIVtAN + flOift' STRtA1.1 tNC4&ERS Date Printed: 08/18/2017 10:03 AM Submittal Approval Sheet, by Submittal Package Page 1 of 1 No. 115 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Navigate/Bio Pharma Lab SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 1891 Rutherford Road CITY: Carlsbad PHONE: ( 619 ) 266-6030 (Industrial Fire Sprinkler Co., Inc.) FAX NUMBER: (619) Largest Building (ft.2): ____ Sprinkled? Construction Type SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): northeast end bf cul-de-sac Rutherford Road TEST INFORMA TION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: )126 PSI Hydrant Number (if applicable):H61303 Elevation of test: 260 (est) Feet Date/Time of Test': Pitot Tube Reading: . PSF Corresponding Flow GPM Total Flow: 2,600 GPM Residual Pressure 109 I PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi of 7,870 gpm. However, velocity at this flow rate exceed the maximum allowable 10 fps criteria. Therefore, the maximum certifiable fire flow is 2,600 gpm. Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x I have witnessed and/or reviewed this water flow information and by personal knowledge and/or on-site observation certify that the above information is correct. Name:Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable):C69606 Signature:________________________________________ / Title/Org:PLo ct Manager Date: 07/11/2017 1891 Rutherford Road - Fire Flow Analysis INDUSTRIAL FIRE SPRINKLER CO., INC. CA LIC.C-16 558084 HI LIC. C-20351 Co LIC. 11-1058 UT LIC. 7336958-5501 VA LIC. 2705 125390A Frc 2O r:I Oi5t) Navigate Bio Pharma 1891 Rutherford Rd ste. 150 Carlsbad, Ca. CONTENTS Hydraulic Calculations Material Cut Sheets 3845 Imperial Ave., San Diego, CA., 92113 0 Phone (619) 266-6030 • Fax (619) 266-6035 15, iivarauiic Laicuiations for Project Name: Navigate BioPharma Location: 1891 Rutherford Road, Suite 150, Carlsbad, CA 92008, Drawing Name: Roof Piping and T.l Model2.cad Design Remote Area Number: 1 Remote Area Location: Lab Area Occupancy Classification: Ordinary Group I Calculation Date: 8/23/2017 Density: 0.15g pm/ft2 Area of Application: 900.00ft2 (Actual 974.81ft2) Coverage per Sprinkler: 130.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 14 Type of System: Wet Volume of Dry or PreAction System: In-rack Demand: N/A gpm at Node: N/A Hose Streams: 250.00 at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 530.37@37.177 Water Supply Information: Name of Contractor: Industrial Fire Sprinkler Co. Inc, Address: 3845 Imperial Ave., San Diego, CA 92113 Phone Number: 619-957-4204 Name of designer: Freddy Alcaraz Authority Having JurisdictionCarlsbad Fire Department Notes: © M.E.P.CAD, Inc. AutoSPRlNK® 12 02.0.61.0 1 8/23/2017 8:06:33AM Page 1 N/A ____________________ ON Actual Device (gpm) I Minimum Flow (gpm) K-Factor (K) Job Number: 17-881 Report Description: Ordinary Group 1(1) P ire (psi) Sprinkler 151 19.94 19.50 5.6 12.682 Sprinkler 152 19.89 19.50 5.6 12.616 Sprinkler 153 20.41 19.50 5.6 13.279 Sprinkler 154 19.89 19.50 5.6 12.610 Sprinkler 155 20.09 19.50 5.6 12.874 Sprinkler 156 19.67 19.50 5.6 12.336 Sprinkler 157 19.75 19.50 5.6 12.434 c Sprinkler 158 19.50 19.50 5.6 12.125 Sprinkler 159 19.99 19.50 5.6 12.747 Sprinkler 160 20.00 19.50 5.6 12.751 Sprinkler 161 20.57 19.50 5.6 13.490 Sprinkler 162 20.57 19.50 5.6 13.497 Sprinkler 163 20.06 19.50 5.6 12.838 Sprinkler 164 20.04 19.50 5.6 12.810 c Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 8/23/2017 8:15:29AM Page 1 #Ll flCflhlt. IC4V$C1tL. I_lOIS ISC4IIIICA emote Area Number: 1 Date: 8/23/2017 Pipe Information 1ode I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) 1ode 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf)to 158 10-0% 5.6 19.50 1 (See Notes) 388% 120 12.125 "•• Route l•"•• Sprinkler, 2E(2 0) mecT(5-0) 91-0 0.124177 -7.621 108 27'-7 19.50 1.0490 47'-81/2 5.926 108 27-7 19.99 2 9'-6 120 10.430 Flow (q) from Route 7 0013689 0.000 107 27-7 3949 21570 96 0.130 107 27-7 19.75 2 11-0 120 10.560 Flow (q) from Route 3 0028983 0.000 106 27-7 5924 21570 1 0 0.029 106 277 19.67 2 (S 5-3 120 10.589 Flow (q) from Route 2 mecT(12 3%) 12-3% 0.049259 0.008 74 27'-7 78.91 2 1570 17 61/2 0.865 74 27'-7 4 13'-0 120 11.463 0000284 0.062 75 27-5% 2915 42600 13 0 0.004 75 27-5/2 0.11 + 31.69 4 9-9% 120 11.528 Flow (q) from Route 9 and 14 0 002825 0.094 76 27-2% 100.94 4.2600 0.028 76 27-2% 4 (See Notes) 41'5 120 11.650 3fE(8-11%),LtE(7-1, 4711 0.001929 0.080 77 27'-O% 82.15 4.2600 89-3% 0.172 77 27'-O% 4 12'-7% 120 11.902 0001312 0.145 78 26'-8Y2 6669 42600 12 7% 0.017 78 26'-8% 4 18'-8 120 12.063 0000834 0.170 79 26-31/2 5221 42600 18 8 0.016 79 26-3% 4 5.4 120 12.249 0000501 0.038 80 26'-21/2 3962 42600 0.003 80 26-2% 4 12'-6 120 12.290 0000253 0.100 81 26-0 2741 42600 12'-6 0.003 ,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.O.61.O 1 8/23/2017 8:06:36AM Page 4 .dLl IlCIuIlL.. IAYIJCALL. LJI'.JI IlCIlIlICI emote Area Number: I Date: 8/23/2017 Pipe Information Elev I Flow added Fillings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this Step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, when Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit applicable, are added directly Total (Foot) (Q) (psi) Friction(Pf) to (Pt) and shown as a (Foot) negative value. 81 26-0 4 (See 8'O% 120 12.393 Notes) 26'-4 0.091 82 25-9% 15.39 4.2600 0000087 mecl(26 4) 34 4Y 0.003 82 25-9% 2 (See 41'-6% 120 12.487 Notes) 23'-4% 0.693 65 24'-2 15.39 2.1570 0.002395 3fE(4'-3Y2), fT(10'-5%) 64-11 0.155 65 24'-2 2 (See 35'8 120 13.336 Notes) 35'-8% -0.451 62 25-2% 8.58 2.1570 0000813 3fE(43A)fT(105/2) 71'-41/2 0.058 62 25'-2% 6.81 4 (See 23'- 10 120 12.943 Flow (q) from Route 15 26'-4 -0.176 61 25-7% 15.39 4.2600 0.000087 2E(1 3 2) 50 2 0.004 61 25-7A 12.02 4 12-6 120 12.771 Flow (q) from Route 16 -0.175 60 26-0% 2741 42600 0000253 12 6 0.003 60 26'-O% 12.21 4 (See 8-4% 120 12.600 Flow (q) from Route 17 -0.112 59 26-3% 3962 42600 0000501 z 8 0004 59 263/a 12.59 4 19'-8 120 12.491 Flow (q) from Route 24 -0.211 58 26-91/2 52.21. 42600 000834 0.000834 '-8 19-8 0.016 58 26-9/2 14.49 4 12'-O 120 12.297 Flow (q) from Route 26 -0.116 57 27 0% 6669 42600 0001312 12-0 0.016 57 27'0% 15.45 4 (See 56-0 120 12.197 Flow (q) from Route 27 35'-31/2 -0.077 56 27'-2% 82.15 4.2600 0.001929 fE(8'-ll%), T(26'-4) 9j31/ 0.176 56 1 27-2/2 18.80 4 9'-g% 120 12.297 Flow (q) from Route 23 -0.094 55 27-5% 10094 42600 0002825 0.028 55 1 27 5/2 29.45 4 13-0 120 12.230 Flow (q) from Route 8 -0.064 54 27-7 7. 1 13039 42600 0004536 13 0 0.059 ,© M.E.P.CAD, Inc. FAutoSPRINK® 12 v12.0.61.0 1 8/23/2017 8:06:36AM Page 5 '4. VI JI.4L'4LJI'4I I IClI I I ICI emote Area Number: 1 Date: 8/23/2017 Pipe Information Elev i Flow added Fittings & Length C Factor Total(Pt) Notes lode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) qt Length) Fixed Pressure Losses, when lode 2 Elev 2 • Total Flow Actl ID Actual Loss Per Unit applicable, are added directly (Foot) (Foot) (psi) Friction(Pf) to (Pt) and shown as a (Foot) (Ft) negative value. 54 27'-7 33.22 4 12-0 120 12.225 Flow (q) from Route 5 0.100 53 27 4% 16362 42600 0006903 12 0 0.083 53 27-4% 27.99 4 12'-0 120 12.407 Flow (q) from Route 6 0.109 52 27'-1% 19161 42600 .009245 0.009245 '-0 120 0.111 52 27-1% 27.09 4 (See 2'101/2 120 12.627 Notes) Flow (q) from Route 22 21'-1 0.026 30 27 0% 21870 42600 0011807 fT(21-1) 23-11 0.282 30 27-0% 61.68 4 (See 174-10 120 12.936 Notes) Flow (q) from Route 4 71-0% 1.667 25 23-2% 28037 42600 0018696 5fE(8 11%) C(26'-4) 245-11 4.597 25 23-2% 6 (See 18'3 120 19.200 Notes) 12'-7 7.904 20 4'-11 Y2 28037 63570 0002662 fE(12 7) 30 0082 20 4'-11 Y2 6 (See 3'3 120 27.186 Notes) 96-10 1.630 15 1 -2% 280 37 6 3570 0.002662 IV(12-7) CV(40-3) fE(12 7) - 100 1 0.266 fl(31'-5) 15 1'-2% 8 0'-6 120 29.083 0.307 10 0-6 28037 82490 0000748 0-6 0.000 10 0'-6 8 (See 104 140 29.390 Notes) 32-8% 1.517 5 3 0 28037 8.5100 0000483 E(32-8%) 43 0% 0.021 -3'-0 8 (See 232'-4 150 30.928 Notes) 3 -3-0 280.37 7.9800 0000582 2E(27-2) 286-8 0.167 3 -3'-0 8 (See 12'0 140 31.095 Notes) 80-0 2 3-0 280.37 8.5100 0.000483 2LtE(23 7%) BFP(-6 000) 92'-0 6.044 E(32-8%) 2 -3-0 8 (See 32'0 150 37.139 Notes) 33-2% 1 4-0 280.37 7.9800 0.000582 E(27'-2), GV(6 0%) 5 65 2% 0 038 ,©M.E.P.CAD, Inc. pffl AutoSPRlNK®12 v1 2.0.61.0 1 8/23/2017 8:06:36AM Page 6 S.flS I I ILO II I4 emote Area Number: 1 Date: 8/23/2017 Pipe Information Mode 1 Elev 1 (Foot) K-Factor Flow added this Step Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Mode 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 250.00 37.177 Hose Allowance At Source Total(Pt) Route 1 1 53037 156 10'-O% 5.6 19.67 1 (See Notes) 34-61/2 120 12.336 ..... Route 2" Sprinkler, E(2'-O), T(5'-O), mecT(5'-O) 12'-0 0.126171 -7.621 106 27'-7 19.67 1.0490 461 61/ 5.875 10.589 Total(Pt) Route 2 157 10'-O% 1 5.6 19.75 1 1 (See Notes) 38'-21/2 120 12.434 •••. Route 3 - Sprinkler, E(2'-0), mecT(5'-O) 7-0 0.127095 -7.621 107 27'-7 19.75 1.0490 45-2% 5.748 10.560 Total(Pt) Route 3 154 10l01,4 5.6 19.89 1 (See Notes) 36'-0 120 12.610 ."•Route4••• Sprinkler, E(2 0) T(5-0) P0(5 0) 12'-0 0.128764 -7.607 104 27 7 19 89 1 0490 48 0 6 179 104 27-7 7.07 2 3'-0 120 11.182 Flow (q)from Route 12 0.006755 0.000 105 27'-7 26.96 2.1570 I 3-0 0.020 105 27'-7 20.09 2 (See Notes) 1'9 120 11.203 Flow (q) from Route 11 mecl(12-3%) 12-3% 0018926 -0.006 74 27-7 4705 2.1570 14 0% 0.266 74 27'-7 4 12'-0 120 11.463 0002615 0.116 73 27'-4 96.81 42600 12-0 0.031 73 27'-4 4 12-0 120 11.610 0002227 0.125 72 27 0% 3876 42600 12'-0 0.027 72 27'-O% 4 (See Notes) 12'0 120 11.762 mecT(26 4) 26'-4 0001135 0:125 71 26-9 , 6168 42600 38-4 0.044 71 26-9 4 (See Notes) 6'- 111/2 120 11.930 mecT(26'-4) mecl(26'-4) 52'-8 0.000295 0.072 70 26-7 7. 29.78 4.2600 0.018 ,©M.E.P.CAD, Inc. jAutoSPRlNK®12v12.0.61.0 1 8/23/2017 8:06:36AM Page 7 Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Elev(Pe) Friction(Pf) 12.020 2fE(4'-3%), mecT(12'-31/2) 0.027 1.084 13.131 -0.150 0.004 12.985 Flow (q) from Route 21 fr(21'-1) -0.083 0.034 12.936 Total(Pt) Route 4 12.616 ••• Route 5 ..... Sprinkler, E(2'-O), T(5'-O), P0(5-0) -7.608 6.180 11.188 Flow (q)from Route 19 mecl(1 2-3%) -0.007 1.045 12.225 Total(Pt) Route 5 12.682 • '• Route 6 Sprinkler, 3E(2-0), PO(5'-O) -7.472 6.440 11.650 Flow (q) from Route 20 mecT(1 2-3%) -0.044 0.801 12.407 Total(Pt) Route 6 12.747 Route 7 ..... Sprinkler, E(2'-O), mecT(5'-O) -7.621 5.303 10.428 0.000 0.002 10.430 Total(Pt) Route 7 Pipe Information Elev I Flow added Fittings& Length C Factor 'lode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Equiv. Fitting (Foot) Pf Friction Loss Per Unit Elev 2 Total Flow Total od e 2 (Foot) (Q) Actual ID Length (psi) (Foot) (Foot) 70 26'-7 2 (See 112'7 120 Notes) 20-11 0008119 50 26-6 [ " 2978 21570 133-6 50 26-6 4 12'-0 120 51 26-10 2978 42600 0000295 12-0 51 26'- 10 31.90 4 (See 9'i/2 120 Notes) 21'-1 30 27'-0V2 61.68 4.2600 0.001135 30-2/z 152 10'-O% 5.6 19.89 1 (See Notes) 3511Y2 120 12'-0 0128817 102 27-7 1989 10490 11% 102 27-7 13.33 2 (See Notes) 92'-9 120 12-3% 0 009943 54 27-7 33.22 2.1570 1 1050A 151 10-01/2 5.6 19.94 1 (See Notes) 38'9 120 11-0 0 129442 101 27-3 19.94 1.0490 101 27'-3 8.05 ______ 2 (See Notes) 983 120 12-3% 0.007241 53 27'-4% 27.99 2.1570 110'-7 159 10-01/2 5.6 19.99 1 (See Notes) 33'9% 120 7'-O 0.130052 109 27'-7 19.99 1.0490 40 109 27-7 2 0-6 120 0003885 108 277 1999 21570 06 .11.) lC4tII%._. iIC1V$C1fl_. LJI%..fl P 'CA IPIUCI emote Area Number: 1 Date: 8/23/2017 ,©M.E.P.CAD, Inc. jrflfl AutoSPRlNK®12v12.0.61.O 1 8/23/2017 8:06:36AM Page 8 164 101-0 5.6 20.04 1 114 27-5% 20.04 1.0490 114 27'51,4 2 113 27-5% 2004 21570 113 27-5% 20.06 2 75 27 51/2 4011 21570 (See Notes) 33'-9% 120 12'-O 0.130652 45,-9% 10-0 120 0.003903 10,-0 (See Notes) 6-3 120 12'-3% 0.014086 17'-6% 153 10'-O% 5.6 20.41 1 103 27'-7 20.41 1.0490 103 27-7 2 104 27'-7 707 21570 (See Notes) 33'-91/2 120 7'-O 0.135068 40-9% 5'-O 120 0.000568 5-0 .. emote Area Number: I Date: 8/23/2017 Pipe Information Elev 1 Flow added Film & Length C Factor Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting Pf Friction $ Elev 2 Total Flow Equiv. (Foot) Loss Per Unit Node 2 (Foot) (Q) Actual ID Length (psi) Total (Foot) (Foot) 160 101-0 5.6 20.00 1 (See 35'-7Y2 120 Notes) 12-0 110 27'-5% 20.00 1.0490 0.130097 1 47-7/2 110 27-51/2 9.45 2 (See 92'9 120 Notes) 12'-3% 55 27'-5% 29.45 2.1570 0.007954 105-0,6 163 101-0 5.6 20.06 1 (See 33'91/2 120 Notes) 12'-0 113 27'-51/2. 2006 1.0490 0130909 155 10-0% 5.6 20.09 1 (See 3821/2 120 Notes) 7'-O 105 27-7 20.09 1.0490 45-2% 0.131251 Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Elev(Pe) Friction(Pf) 12.751 ..... Route 8 • • Sprinkler, E(2-0), T(5'-O), mecT(5'-O) -7.551 6.194 11.394 Flow (q) from Route 13 mecT(12-3%) 0.000 0.836 12.230 Total(Pt) Route 8 12.810 •• ... Route 9 ..... Sprinkler, E(2'-O), T(5'-O), mecT(5'-O) -7.551 5.983 11.242 -0.000 0.039 11.281 Flow (q) from Route 10 mecT(1 2-3%) -0.000 0.247 11.528 Total(Pt) Route 9 12.838 ..... Route 10..... Sprinkler, E(2'-O), T(5'-O), mecT(5'-O) -7.551 5.994 11.281 Total(Pt) Route 10 12.874 • ... Route 11 • • Sprinkler, E(2'-O), PO(5'-O) -7.607 5.936 11.203 Total(Pt) Route 11 13.279 ..... Route 12 ..... Sprinkler, E(2'-O), P0(5-0) -7.608 5.507 11.179 0.000 0.003 11.182 Total(Pt) Route 12 ,©M.E.P.CAD, Inc. . AutoSPRINK®1202.0.61.0 1 8/23/2017 8:06:36AM Page 9 emote Area Number: 1 Date: 8/23/2017 Pipe Information 1ode 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot)Pf Friction • Loss Per Unit (psi) Elev(Pe) 4ode 2 Elev2 00) Total Flow Actual ID Total (Foot) Friction(Pf) 161 101-0 5.6 20.57 1 (See Notes) 32'91/2 120 13.490 .. .. Route 13• Sprinkler, E(2'-O),mecT(5 -0) 7-0 0.137048 -7.551 111 27 5% .. 20 57 1 0490 5 451 111 27-51/2 2 51-0 120 11.390 .000972 0.000972 -0 0.000 110 27'-5% - 9.45 2.1570 5'O 0.005 11.394 Total(Pt) Route 13 162 101-0 5.6 20.57 1 (See Notes) 32'9% 120 13.497 ..... Route 14••••• Sprinkler, E(2'-O), P0(5-0) 7'-0 0.137120 -7.551 112 27-5% 't 20.57 1.0490 112 27-5% 11.12 2 (See Notes) 11 9 120 11.400 Flow (q) from Route 18 mecT(12 3%) 12'-3% 0009110 -0.000 75 27-5% 3169 21570 14-0% 0128 11.528 Total(Pt) Route 14 63 24'-111/2 6.81 4 8'-2 120 13.060 ••'•' Route 15••••• Flow (q) from Route 25 0.000019 -0.118 62 25-2% 6.81 4.2600 8-2 0.000 12.943 Total(Pt) Route 15 81 26'-0 2 (See Notes) 91-6% 120 12.393 ••••• Route 16••••• 2-3 mecT(1 %) 2fE(4'3%), 2f1(10'5%), mecT(12'-3%) 54'-2 0.001516 0.157 61 25-7% -:L•- 12.02 2.1570 145-8 0 221 12.771 Total(Pt) Route 16 80 26'-2% 2 (See Notes) 91'-6% 120 12.290 ••••• Route 17••••• mecT(12'-3%) 2fE(4-3%) 2f1(10-5%) mecl(12'-3%) 54'-2 0.001559 0.083 60 26-01/2 12.21 2.1570 145 8 0227 12.600 Total(Pt) Route 17 111 27'-5% 2 8'-0 120 11.390 ••••• Route 18•"•• 0001312 -0.000 112 27 5% 1112 21570 8'-0 0.010 11.400 Total(Pt) Route 18 103 27'-7 2 5-0 120 11.179 ""• Route 19•'••• 0.001836 -0.000 102 27'-7 P 13.33 2.1570 5'O 0.009 ,©M.E.P.CAD, Inc. plfflAutoSPRlNK®12v12.0.61.0 1 8/23/2017 8:06:36AM Page 10 Date: 8/23/2017 Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as a negative value. Elev(Pe) Friction(Pf) 11.188 Total(Pt) Route 19 11.610 ..... Route 20 ..... mecT(1 2'-31/2). 0.025 0.016 11.650 Total(Pt) Route 20 11.930 ••••• Route 21 mecT(12'-3%) -0.050 1.105 12.985 Total(Pt) Route 21 11.762 ••••' Route 22••••• mecl(12'-3%) mecT(12'-3%) -0.035 0.900 12.627 Total(Pt) Route 22 11.650 ••'••Route 23••••• mecl(1 2'-3%) 8fE(4-3%) mecT(12'-3%) -0.000 0.647 12.297 Total(Pt) Route 23 12.249 •• •' Route 24 mecT(1 2'-3%) 2E(6'-2) 2mecT(12-31/2) 0.008 0.234 12.491 Total(Pt) Route 24 13.336 ....• Route 25 ..... fT(10'-5%) 6fE(4-3%), 2fEE(2'-2%), fT(10'-5%), mecT(12-3%) -0.333 0.058 13.060 Total(Pt) Route 25 12.063 ..... Route 26 mecT(12'-3%) E(6'-2), Z, mecT(12'-3%) -0.032 0.266 12.297 Total(Pt) Route 26 11.902 Route 27 ..... mecT(1 2'-3%) E(6-2), Z, mecT(12-3%) -0.003 0.298 12.197 Total(Pt) Route 27 8/23/2017 8:06:36AM Page 11 •'_ VI I4I.S 'I# III(AIIIICI emote Area Number: 1 73 27-4 2 (See 9'3 120 Notes) 12'-3% 101 27-3 8.05 2.1570 , 0.000722 21-6% 71 26'-9 2 (See 1076 120 Notes) 12'-3Y2 51 26-10 .. : 31.90 2.1570 0.009222 119-10 72 27-0% 2 (See ( 1076 120 [-71 52 27-1% ., : 27.09 1570 Notes) 0.006814 -112 I 76 27'-21/2 2 (See 127'-6 120 Notes) 591 56 27'-21/2 186-6% 18.80 2.1570 0.003467 79 I 26'-3% I 2 (See 92-6 120 49-2% 59 26'-3Y2 12.59 2.1570 Notes) 141-8% 0.001651 65 241 2 2 (See 458% 120 Notes) 681 21570 0000530 63 24-11% 78 26'-8% 2 (See 936 120 Notes) 30'-9 58 26-91/2 14.49 2.1570 0.002141 124-3% 77 27-0% 2 (See 9211 120 - Notes) 30'-9 57 27 0% 1545 21570 123'-8 0002412 © M.E.P.CAD, Inc. ffi AutoSPRINK® 12 v12.0.61.0 1 Pipe Information Elev 1 Flow added Fittings & Length C Factor Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting (Foot) Pf Friction Loss Per Unit (q) Equiv. Elev 2 Total Flow Total Node 2 (Foot) (Q) Actual ID Length (psi) (Foot) (Foot) .11./ IlCitliL.. JCAVIjC4L., LIflJI IICAIIIICI emote Area Number: 1 Date: 8/23/2017 1 [C VliMir J Actual Inside Diameter 4.87 = F Schedule 40 Steel Pipe Inside Diameter) Factor Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 Fgeqe°? ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BF P Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90* Elbow EE 45* Elbow Eel 11%°Elbow Ee2 221,40 Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. AutoSPRlNK® 12 v12.0.61.0 1 8/23/2017 8:06:36AM Page 12 5000 t,1,II-t.IoJ 4000 4500 uuu 000 2500 3500 Flow - gpm ,© M.E.P.CAD, Inc. AutoSPRINK® 12 02.0.61.0 8/23/2017 8:06:34AM Paqe 2 0 6C Job Name: Navigate BioPharma Remote Area Number: 1 150 - 1I 12( 13! 30 15 45 Water Supply mary Sheet Sum Node: I H-- Static 530.3' Pressure 125 102 126.000 . 2600 00109000 _______ 280.37 t 530.37 37.177 with Hose Allowance at Source S stem demand curve ....I1IIIIJ.I.IJ.1_l_IIIIIIPIIII,IcI,I 111111111 IllilpIpi 1111111 liii I 1111111 I iii Hydraulic Graph N 1.85 Date: 8/23/2017 FireLock® V27, K5.6 Models V2703, V2707, V27041tV787 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response ;i V2703/V2704 V2707/V2708 V2707 V2708 Upright Pendent Recessed Pendent Approvals/Listings: See Victaulic Publication 10.01 for more details. A tauIcr 40.10 Technical Specifications: Models: V2703, V2704, V27077 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By D ate Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 If........... --. ...... victaulic.com I Sprinklers I FireLocc- I K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: Standard: 5.0 mm Quick Response: 3.0 mm Load Screw: Bronze per UNS 065100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: Open End: V27 Recessed: V27-2 Sprinkler Finishes: Plain Brass Chrome plated White painted3 Black painted3 Custom painted3 Proprietary Nickel Teflon2 coating3 VC-2504 155, 200, 286 SR Only: Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. victautic.com I Sprinklers I FireLocK I K5.6, V27 I Publication 40.10 Approvals/Listings: APPROVALS/LISTINGS Model V2703 V2707 V2707 V2704 V2708 2708 Orifice Size (inches) 1/2" 1/2" i/f' 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 - 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick 4zrizkz Deflector Type Upright Pendent Recessed Upright Pendent Recessed 'Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/51°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/51°C 135°F/57°C 135°F/57°C 115°F/79°C 175°F179°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 200°F/93°C 200°F/93°C 175°F/79°C 115°F119°C 175°F/79°C 175°F/79°C 286°F/141°C 286°F!141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F157°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C FM 200°F/93°C 200°F/93°C 115°F/79°C 175°F/79°C 175°F/791C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F!57°C 135°F/57°C 135°F/57°C 135°F/57°C 115°F/79°C 115°F179°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C NYC/MEA 62-99-E 200°F/93°C 200°F193°C 175°F/79°C 175°F/79°C 175°F179°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F193°C 200°F!93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F!93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93°C 360°F/182°C 135°F!57'C 135°F!57°C 155°F/68'C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/14°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F!182°C 360°F/182°C 286°F/141°C 286°F/141°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 135°F/57°C 155°F/68°C 175°F/79°C 155°F/68°C VdS 200°F/93°C None None 175°F/79°C None None 286°F/141'C 360°F/1 82°C 135°F/57°C 155°F/68°C 175°F/79°C 155°F/68°C CE 200°F/93°C None None 175°F/79°C None None 286°F/141°C 360°F/182"C 286°F/141°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with /2" adjustment escutcheon only, quick response Note: Listings and Approvals as of printing. All are approved open. victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 Dimensions: I 37 mm 41 mm 60 mm 2/8"I J 60 mm 1W! I 41 mm Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/60 mm Max. Hole 2/51 mm Min. Hole 1 NC! 30m Typical Ceiling Tile 17 mm IX!! Finished Surface 30 nm 43 mm ___________ ________ MAXIMUM RECESS 25A6'/ 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 2W/60 mm Max. Hole 2751 mm Min. Hole 37 rnm 8mm Typical Ceiling Tile 24 rnm , \—Finished Surface—/ 24~ mm MAXIMUM RECESS - 251!! - 75 mm MAXIMUM EXTENSION 3/4" Adjustment Recessed - V2707, V2708 (drawing not to scale) If ct!m I Sprinklers I FireLocK" I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns - Trajectory 10' 3.0n 7 psi — • 48 kPa 15 psi 103 kPa 30 psi 207 kPa 2 4 8 10' 12' 14' 0.6m 1.2m i8n 2.4. 3.0n 3.7n 4.3m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory I I -—'4';-- ----- — \ '\_:4. -_%.__ -- ii i 2' 4' 6' 8' 10' 12' 14' 16' 0.6. 1.2m 1.8n 2.4m 3.0r 3.7m 4.3m 4.9. NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 8' 24, 6' 4' 1.2n 2' 06 10, 3.0 8' 2.4rn 6' 1.0n 4' 1.2m 2' 06rn 0 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLoc. i K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - °FI°C Glass Bulb Color - Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 1350F/570C 100°F/380C Orange Ordinary C 1550F/68°C 100°F/38°C Red Intermediate E 1750F/79°C 150°F/650C Yellow Intermediate F 200°F/930C 150°F1650C Green High J 286°F/141°C 225°F 8/107°C Blue Extra High 7 - K M 360°F/1 82°C Open 300°F/1490C - Purple No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707,V2108Pendent V2707, V2708 Recessed Pendent V2703,V27o4Upright AWARNiNG Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Installation Reference should always be wade to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at vicfaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is registered trademark of Victaulic Company. F "Thc INCH" QUICK RESPONSE A UTOMA TIC SPRINKLER MODEL GL5606 ONE INCH ADJUSTABLE PLATE CONCEALED PENDENT DESCRIPTION AND OPERATION The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operations approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards. This sprinkler offers the additional feature of greatly in- creased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal I" of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate or an optional 2 3/4" diameter ceiling plate color finished to match the specifier's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's GL5606 Concealed Sprinkler utilizes a 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off' designed cover plate is easily installed and with a nominal 1" of adjustment makes it easier to get a proper fit at the ceiling. Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern to extinguish or control the fire. th1h1k 4 t 'll 1911 FLAT TECHNICAL DATA 'See reverse side for Approvals and Specifications. -Temperature Ratings - 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate -Water Working Pressure Rating - 175 psi (12 Bars) -Factory tested hydrostatically to 500 psi (34 Bars) 'Maximum low temperature glass bulb rating is -67°F (-55°C) -Frame - bronze • Deflector - brass • Screw - brass 'Lodgement Wire - stainless steel • Bulb seat - copper 'Spring - nickel alloy . Seal - teflon . Drop Pin - stainless steel 'Bulb - glass with alcohol based solution, 3mm size -Cover Plate - brass • Upper Escutcheon Assembly - steel 3 5/16" diameter plate 2 3/4" diameter plate QUICK RESPONSE WHITE FLAT PLATE CONCEALED PENDENT NOTE: Globe's wrench P/N 332765 must be used to install this sprinkler. -SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.RA. MAXIMUM CEILING TEMPERATURES 3F. F r 57'C/68'C TEMPERATURE 1 DC: ORDINARY ORANGE/RED INTERMEDIATE 1 ii F YELLOW/GREEN NOV 2016 GFS-150a (Formerly A-38) "THE INCH" QUICK RESPONSE A UTOMA TIC SPRINKLER MODEL GL5606 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT SPECIFICATIONS NOMINAL THREAD SIZE LENGTH FLAT COVER "K" FACTOR I PLATE FINISHES I I 5.6 1/2"NPT 2 1/2" I Chrome (80 metric) (15mm) (6.4cm) White Painted Other Finishes' .2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 2FOR PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. APPROVALS STYLE SIN MODEL HAZARD1 135°F (57°C) Flat Cover Plate 155°F (68°C) Flat Cover Plate cULus *FM NYC-DOB MEA "136-F (57°C) 155°F (68°C) **155F (68°C) 175°F (79°C) I 200°F (93°C) Sprinkler Sprinkler Sprinkler Sprinkler I Sprinkler 10192E Adjustable Concealed GL5606 LI-I/OH X X X X I X X X X Pendent 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. *FM APPROVED AS STANDARD RESPONSE **NO FM APPROVALS OH: ORDINARY HAZARD CROSS SECTIONS LH. LIGHT HAZARD D'MIN. —1 HOLE IN CL1NG F~__1 21/4' DIA. MIS. HOLA IN CE1UNG r 7/8' DIA.-1 I —i 7/8 DIA.—H I" x 1/2-1 1EDUCER - I RED( 1' x 1/2 '_ " / II 1 2 3/4" MAX. 2 3/4" MAX. 17/8" MIN. 17/8" MIN. DEFLECTOR SUPPORT DROP PIN SHELL DROP PIN I 2 3/4' DIA. 1/8'i I 3 5/16" DIA. I 118-J FLAT COVER PLATE FLAT COVER PLATE 1" ADJUSTMENT FLAT PLATE CONCEALED PENDENT FLAT COVER PLATE SIZES WHITE 135°F (57°C) PART# WHITE 155°F (68°C) PART# CHROME 135°F (57°C) PART# CHROME 155°F (68°C) PART# 2 3/4" DIA. 332726 332731 332724 332729 3 5/16" DIA. 332706 332711 332704 332709 ORDERING INFORMATION SPECIFY -Quantity . Model Number . Style . Orifice Thread Size .Temperature. Finishes desired -Quantity - Wrenches - P/N 332765 Quantity - Protective Caps - P/N 332695 (31 FIRE SPRINKLER CORPORATION NOV 2016 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. GFS-1 50a (Formerly A-38) Page 1 of 4 I MICROFAST@ QUICK N I(IIs1G® l:II[.1iu.nyA RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS C®LJS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Chart 1 and Design Criteria on for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 "F (-55 "C) Overall Length: 2-3/16" (56 mm) *cuLus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Viking Technical Data may be found on Deflector: Brass UNS-C23000 or Copper UNS-C19500 The Viking Corporation's Web site at Bulb: Glass, nominal 3 mm diameter http:/Iwww.vikinggroupinc.com. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Web site may include a more recent PTFE Tape edition of this Technical Data Page. Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS- S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sorinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135"/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F052114 Rev 15.2 1 --- Page 2 of 4 MICROFAST® QUICK N I I(jF1J l:III.Y.iv RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature 2 Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 ¶ (65 °C) Green High 286 °F (141 °C) 225 °F (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 ¶ (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap ----, fl Wrench Flat - Figure 1: Standard Sprinkler Wrench 10896W1B Form No. F052114 Rev 15.2 Page 3 of 4 MICROFAST® QUICK NIKI II SPRINKLER VK300 (K5.6) RESPONSE UPRIGHT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart I (UL) Ieper. KEY Microfast Quick Response Finsti I Al X 4 Escutcheo7 (if appIich]ef Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 SIN Number' NPT I BSP U.S. I metric2 Inches I mm cULus VdS I LPCB I NYC8 I CE 12978 VK300 1/2" 15 mm 5.6 I 80.6 2-3/16 56 -- Al B2 See footnote 7.I 7( ELL L' I•)tL'! rJ T7I77 g j4ir.i11tJ 06661B VK300 1/2' 15 mm 1 5.6 I 707 1 2-3/16 - 56 1 Al, B2 ISee footnote 7.I -- Approved Temperature Ratings Approved Finishes A- 135 5F (57 °C), 155 7F (68 °C), 175 7F (79 7C), 200 F (93 °C), and 286 7F(141°C) - Brass, Chrome, White Polyester5'6, and Black Polyester56 B - 155 F (68 CC), 175 °F (79 °C), 200 7F (93 °C), and 286 F (1417C) 2- ENT 6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F052114 Rev 15.2 Page 4014 MICROFAST® QUICK 4 lI(I FIG RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) - Microfast Quick Response Tx Upright Sprinkler VK300 heon (if 2ppl Maximum 175 PSI WWP _(12bar) Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT BSP U.S. metric2 Inches mm Number' (Refer also to Design Criteria below.) 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 t.1l(s Product .777r1 T1EI1'1fl I•JiIt 06661B VK300 1/2" 15 mm 1 5.6 80.6 1 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175 °F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 - Brass, Chrome, White Polyester', and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 *F, (141°C) Polyester 2 - Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F052114 Rev 15.2 Page 1 of 4 MICROFAST® QUICK J I I(II%1G® RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESCRIPTION The Viking Microfast! Quick Response Upright Sprinkler VK350 is a small, thermosensitive, glass-bulb spray sprinkler available in several different fin- ishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester, and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class Series 2000 [] VdS Approved: Certificates G414017 and G414018 LPCB Approved CE CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0786-CPD-40278 3 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP, 3/4" NPT, 20 mm BSP Nominal K-Factor: 8.0 U.S. (115.2 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-5/16" (59 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast5 Quick Response Upright Sprinkler VK350 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK350 with a 1/2" thread, Brass finish and a 155 °F/68 C temperature rating = Part No. 18259AB Available Finishes And Temperature Ratings: Refer to Table 1. Form No. F_033014 16.06.30 Rev 16.1 Replaces Form F 033014 Rev 14.2 (Added new PNs for CCCF approved sprinklers; removed black PTFE) Page 2 of 4 N II(IIs16® MICROFAST@ QUICK l.i:II[.n,yAwA RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast Quick Response Upright Sprinkler VK350 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. f:1I TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb Color Ordinary 135 ¶ (57 °C) 100 °F (38 C) Orange Ordinary 155 F (68 C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 ¶ (65 °C) Yellow Intermediate 200 ¶ (93 °C) 150 °F (65 C) Green High 286 °F (141 C) 225 ¶ (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester and ENT. ENT in all temperature ratings except 135 °F (57 C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proaosed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033014 16.06.30 Rev 16.1 Page 3 of 4 MICROFAST® QUICK KJ I16i® SPRINKLER VK350 (K8.0) S I.j:II[.nu.yAwA RESPONSE UPRIGHT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart I (UL) r rnperure KEY Microfast Quick Response Upright Sprinkler VK350 [Al X4- Escuiche0n (i ppjab() Maximum 175 PSI (12 bar) WWP Base Part SIN Thread Size K-Factor Nominal Overall Length Listings and ApprovaIS3 (Refer also to Design Criteria.) Number' NPT BSP U.S. metric' Inches mm cULus4 VdS LPCB 18257 VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B2 Al Al B17 -- 18278 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B2 Al Al B17 -- 18259 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, B2 Al -- B18 -- 20382 VK350 3/4" -- 8.0 \115.2 2-5/16 59 -- -- -- -- C3 20237 VK350 -- 20 mm 8.0 115.2 2-5/16 59 -- -- -- -- C3 I.1tE l7TI L7W IT7A!1?fl I.Jfll 06665B VK350 3/4" -- 8.0 1 115.2 1 2-5/16 1 59 Al, B2 Al Al B17 -- 14817 VK350 -- 20 mm 80 115.2 2-5/16 59 Al, B2 Al Al B17 -- 06764B9 VK350 1/2" 15 mm 8 115.2 2-5/16 59 Al, B2 Al . -- A18 -- Approved Temperature Ratings Approved Finishes A- 135°F (57 °C) 155°F (68 °C) 175°F (79 °C) 200°F (93 °C), and 286 F(141 C) 1 - Brass, Chrome, White Polyester,,, and Black Polyester56 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2-ENT5 C - 155 °F (68 °C) 3-Chrome Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40278. 'The 1/2" NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: The Microfasta Quick Response Upright Sprinkler VK350 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033014 16.06.30 Rev 16.1 Page 4 of 4 on MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart 2 (FM) EY Microfast Quick Response r I Upright Sprinkler VK350 Maximum 175 PSI WWP _(12bar) Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT BSP U.S. metric2 Inches mm Number' (Refer also to Design Criteria below.) 18257 VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B2 18278 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B2 18259 VK350 1/2" 15 mm 8.0 115.2 1 2-5/16 59 Al, B2 NOTICE1Product Below Limited VT'71ff7 U(i1iPlLocalAVikingI•JiIt 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B2 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B2 06764135 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, B2 Approved Temperature Ratings Approved Finishes A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 "F (93 °C), and 286 °F (141°C) 1 Brass, Chrome, White Polyester4, and Black B - 155 °F (68 °C), 175 °F (79 "C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 5The 1/2' NPT Large Orifice Sprinkler is listed and approved for retrofit Only when installed in accordance with NFPA 13. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above) FM Ar,oroval Requirements: The Microfast® Quick Response Upright Sprinkler VK350 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033014 16.06.30 Rev 16.1 Replaces Form F_033014 Rev 14.2 (Added new PNs for CCCF approved sprinklers: removed black PTFE) Description Kydex rings are used to correct miscut or oversized holes in ceiling material and as a backing material behind sprinkler canopies. When ceiling tile are being replaced, the size hole that has been cut in the ceiling material to accommodate the sprinkler and escutcheon is often larger than the original sprin- kler canopy. Use of the Kydex ring provides coverage of the oversized hole. Use of the Kydex ring also allows replacement of ceiling tile without the removal of most types of sprinkler canopies. This means the sprinkler system stays "online" during ceiling tile replacement or repair. Installation Kydex rings are installed as a to meet the ceiling material. backing material behind exist- For existing applications, cut ing or new sprinkler canopies. the Kydex ring from the out- When installing with a new side diameter to the inside canopy installation, slip Kydex diameter, then twist the cut ring over sprinkler the install area apart and slip behind the sprinkler/ canopy assembly. existing sprinkler head/canopy The Kydex ring will be held assembly. Scissors are the in place when the sprinkler recommended tool for cutting canopy has been adjusted the Kydex material. Specifications Material: .028' Kydex Color: White I Dimensions: OD=4.0" ID=1.75" Packagir.g: 100/pyDag ©1996-2007 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc F P r 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-154. For questions: 1 800 344-1822 • 1 800 344-3775 fax www.fppi.com 19 .iirn ri Iii.i EASYFLEX Flexible Sprinkler Drops are designed to significantly reduce labor and installation costs. By eliminating the need for pipe cutting and midline connections, you save valuable time and money. Easyflex flexible sprinkler connections offer braided and unbraided flexible hoses in 2',3',4',5', and 6' with top loading or front loading brackets for variety of ceiling and wall applications I Bars, metal studs hat channels wood beams, concrete sidewalls and wore The system is qualified to be installed at commercial, hotel retail, restaurants cultural, entertainment, educatonal, government, healthcarè, and religious buildings. EASYFLEX Flexible Sprinkler Drops Appliance Standards National Fire Protection Association (NFPA: NFPA 13 Standard for the Installation of Sprinkler Systems NFPA 13D.: Stanlard for the Installation of Sprinkler Systams in One and Two-Family Dwellings and Manufadured Homes NFPA 13R: Standard for Installation of Sprinkler Systems in residential Occupancies up to and including four stories in height NFPA 13 Section 9.2,1.3.3.3: No hangers are required for Ilexible connections as long as the length does not exceed 6Th American Society for Testing and Methods (ASTM): ASTM C6C5 Standard specifications for the manufacture, performance and testing of metal suspension systems for acoustical tile and lay-in panel ceilings ASTM C6c-6: Standard practice for instaltotion of metal ceiling suspension systems for acoustical tile and lay-in panels Undrwriters Laboratories, Inc. (UL/ULC), cUL us 2443: -• Standard frr flexible spunkier hose with fittings for fire protection service hternational lauilding Code (IBC) Section 1621 /American Society of Civil Engineers (ASCE) 7 9,6.26.2 & 9.6.2.6.2.2: Flexible SVinkler Connections are an alternative solution to install without seismic escutcheons Joo Name: Engineer / Architect: JoD Location: Wholesaler: Submittal Date: Contractor: WEST OFFICE Tog Free (88) 577-8999 9 infoeasyflexusa.com EAST OFFICE Toll Free (555) 388-2600 • info@ieasyflexeast.com ECHNICAL SPECIFICATIONS SPECIFICATIONS Lengths Available 28, 40, 48', 60" and 67' Outlet 1/2" or 3/4" Hose Type Uribraided Max. Ambient 225"F Temperature Rating Max. Working 175 psig Pressure Rating Hose Stainless Steel 304 Not & Nipple Zinc-Plated Steel j Sealing Gasket EPDM/ NYLON / Isolation Ring 6' (ULJULC) Minimum Bend Radius DO NOT bend within 2.52 Inches from connection nuts "No hangers and seismic escutcheons required Required torque to assemble reducer and nipple with the flexible hose :50 ft-lb Connection Inlet J_1"NPT Outlet 1/20r3/4"NPT ,@,, FRICTION LOSS DATA USTEU EFU Series Unbraided Hose szm TBS-PA Bracket Systems Length (in.) KFacto i 0 Max. Number o0 Bends Equivalent Length 1 in. f Schedule 40 Pipe, ft. 40 3/4" 8.0 2 39 1/2" 5.6 48" 2 38 3/4" 8.0 2 1 44 60" 1/2" 5.6 3 55 3/4' 8.0 3 61 67' 1/2" 5.6 3 63 _/" 83 (JL: 6" minimum bend radius, where C120 MFD,201601 WEST OFFICE Toll Free (888) 577-8999 • inlo@easyflexusa.com EAST OFFICE Toll Free (855) 388-2600 • info@easyflexeast.com The purl in lip is not capable of supporting NFPA 13 fire sprinkler pipe at 1(wt.) +250 lbs mm. When manufacturers specify 200 lbs. max. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 551 REVOLVER Im THREADED BRACKET SIZE - 3/8' rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and S.S. LISTING/APPROVAL - 203 - EX 2551 PATENT - No. 6,568,642 FUNCTION - Listed to support max. 4" Steel. CPVC or Copper pipe. Listed hanger component per NFPA 13. INSTALLATION - per NFPA 13. Space by pipe type. Install on vertical mounting surface of wood, concrete or steel. Center hole accepts 3/8" and 1/2" NFPA 13 fasteners. ADDITIONAL UL LISTED FASTENERS PER NFPA 13 FOR STEEL PIPE LOADS -SEE TABLES.. 2.0312 tø 1 3/8 11.250 rk .v, FEATURES * Universal fastener array for enhanced mounting. * Double fastener installation allows: Vertical - Hangs plumb from first fastener. Stops wood splitting along the grain. Horizontal - When vertical space is limited. * Radius -Tapped orifice: Aligns rod for easy thread engagement and eliminates structural deficiencies associated with rod inserts. * No speed/pal nuts required. ORDERING - Part # and finish. ® UL Fasteners Locations 1 BorE 3@ A-C-E (DO ® 2@ B-E 3@ B-D-F ® 2@ A-C 4@ A-C-D-F Wood - No Pre Drill Mm. Mm. Max. Fastener Qty. Pipe Steel - 1/4 or #14 Tek Mm. Mm. Max. Thickness Qty. Pipe Steel - #10 SMS or #905 Min. Mm. Max. Thickness Qty. Pipe 1/4x1V2 Lag 1 2 14 GA. 1 3 18 GA. I 2','2 24 24 2 3 3 4 #14 x 1 /2 SMS 1 2 16 GA. 1 2 Y2 2 4 2 4 20 GA. 2 3 44 #16x2DS 2 2 18 GA. I 2'A 3 4 2 3 22 GA. 3 3 Wood - Thru 5/8" Gyp. 20 GA. * 1 2 1/4 x 2 Lag 1 2 2 4 *@BONLY 2 3 3 4 OS— Drive Screw #14 x 2 SMS 1 2 SMS Sheet Metal Screw 2 4 22 GA. 3 2 '/2 Gyp= Gyp... Board 1/09 ?owers FASTENERS PRODUCT INFORMATION VertigoTM Vertigo TM Rod Hangers t.J '1'k • -14-14(; 11 ;j I L01 Vertigo is an all steel threaded fastening system for suspending steel threaded rod vertically overhead in pipe hanging, fire protection, electrical conduit and cable-tray applications. Vertigo are available in three versions which can be installed in a variety of base materials including steel purlins, bar joists and beams, wood frame columns and beams, as well as concrete ceilings, beams and columns. Steel threaded rods in 1/4", 3/8" and 1/2" diameters can be vertically suspended with Vertigo. In wood and steel base materials, Vertigo is also offered in a side mount style for lateral installation of 1/4" and 3/8" diameter steel threaded rods onto joists, columns and overhead members. For all steel and wood Vertigo fasteners, a universal Vertigo Socket Driver is recommended to provide proper installation with a screw gun or hammer drill. Concrete Vertigo fasteners should be installed with the appropriate size standard drive sockets and adjustable torque, battery powered screw gun or hammer drill. Hanging Pipe and Sprinkler Systems • Suspending Conduit and Cable Trays Lighting Systems and Overhead Utilities • HVAC Ductwork and Strut Channels Suspended Ceilings • Mounting Security Equipment + One system for all rod hanging applications in steel, wood and concrete + Ease and speed of overhead installation +. Lower in-place cost, when compared to beam clamps, lag bolts and dropins + Steel and wood Vertigo can be installed with a screw gun or hammer drill + Concrete Vertigo can be installed with an adjustable torque, battery powered screw gun or hammer drill + Side mount versions available for steel and wood Vertigo The universal socket can be used for the steel and wood Vertigo APPROVALS AND LISTINGS FM Approvals (FM) - (see listing for applicable sizes and types). Pipe Hangers components for automatic sprinkler systems - File No. JI 3015153 Underwriters Laboratory (UL) - (see listing for applicable sizes and types). Pipe Hangers - File No. EX 1289 Luminaire - File No. E362339 SECTION CONTENTS Page No. General Information....................1 Installation Specifications............2 Material Specifications ...............2 Performance Data ........................3 Ordering Information..................7 Steel Vertigo Wood Vertigo Concrete Vertigo (Wedge-Bolt OT) ANCHO4IATERIALS Zinc Plated Carbon Steel ANCHOR SIZE RANGE (TYP.) 1/4" to 1/2" for Steel 1/4" to 1/2" for Wood 1/4" to 1/2" for Concrete SUITABLE BASE MATERIALS Steel Purlins and Beams Wood and Timber GUIDE S S I [' I [.] F.. Normal-Weight concrete CSI Divisions: 03 16 00 - Concrete Anchors, 05 05 19 - Post-Installed Concrete Anchors, Structural Lightweight concrete 05 05 23 - Metal Fastenings and 06 05 23 - Wood, Plastic, and Composite Fastenings. Rod Hollow Core Concrete Plank Hangers shall be Vertigo anchors as supplied by Powers Fasteners, Inc., Brewster, NY. Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com Installation Guidelines When installing Vertigo 4 fasteners, eye protection should be worn as a safety precaution. If pre-drilling is required (certain types of wood truss/wood joist and all concrete base materials), select the recommended drill bit type and diameter. For Concrete Vertigo only, drill to the appropriate embedment depth, adding at least one diameter (1/4" to 1/2") to the drilling depth to prevent the tip of the fastener from running into a dead end at the rear of the anchor hole. Concrete Select the appropriate socket driver for the anchor size and type to be installed and mount into chuck of installation tool. Insert the Vertigo fastener into the socket driver, and install perpendicular to the base material surface. Drive the fastener with a smooth steady motion until the coupling is firmly seated against the surface of the base material. Thread the appropriate Steel diameter steel threaded rod or threaded bolt into the coupling. The threaded rod or bolt should fully engage the thread length of the coupling on a vertical mount fastener. The threaded rod or threaded portion of the bolt can pass through coupling of a side Wood mount fastener. For UL and FM listings for Pipe Hangers, Steel Vertigo should be installed with a retaining nut. I ?owers VertigoTM PRODUCT INFORMATION FASTENERS Steel Vertigo Point Style #3 #5 Self Drilling Range 0.036" (20 gauge)— 0.188" (3/16") 0.188"(3/16")— 0.500" (1/2") Screw Size (U NC) 1/4-20 thread 1/4-20 thread Root Diameter (in.) 13/64 13/64 Thread Length (in.) 1-3/16" (1-1/2"screw) 31/32"(1-1/2"screw) Flange Thickness (in.) 1116 1/16 Drill Speed (RPM) 500-1,500 500-1,500 Install with universal steel and wood socket. Wood Vertigo Screw Size 1/4" Thread Forming 5/16" Thread Forming Pre-drill Diameter (in.) (if required) 1/8 1/8 Point Style Type 17 Type 17 Root Diameter (in.) 3/16 7/32 Thread Length (in.) Screw length less 5/16 Screw length less 5/16 Flange Thickness (in.) 1/16 1/16 Install with universal steel and wood socket. Vertigo Couplings (Steel & Wood) Screw Size 1/4" 3/8" 1/2" 1/4" 3/8" Coupling Size and Type Vertical Vertical Vertical Side Side Thread Size (UNC) 1/4-20 3/8-16 1/2-13 1/4-20 3/8-16 Thread Depth (in.) 3/8 3/8 3/8 (through) (through) Width (flat to flat) (in.) 5/8 5/8 5/8 5/8 5/8 Height (in.) 13/16 13/16 1 13/16 13/16 13/16 Concrete Vertigo (Wedge-Bolt OT) Rod Diameter/Anchor Size 1/4" 3/8" 1/2" ANSI Drill Bit (in.) 1/4 1/4 3/8 Overall Screw Shank Length 1-1/4 1-1/2 2-3/4 Anchor Thread Length (in.) 1-1/8 1-3/8 2-1/2 Root Diameter (in.) 15/64 15/64 23/64 Coupling /Washer Height (in.) 27/64 9/16 53/64 Integral Washer O.D. (in.) 31/64 39/64 31/32 Coupling Thread Size (UNC) 1/4-20 3/8-16 1/2-13 Coupling Thread Depth (in.) 3/8 1/2 3/4 Socket Driver Size (in.) 3/8 1/2 11/16 Install with universal steel and wood socket. MATERIAL SPECIFICATIONS Steel and Wood Vertigo Component Component Material Screw Body AISI 1018-1022 (Case Hardened) Coupling AISI 1018-1022 (Case Hardened) Zinc Plating ASTM 8633, SC1,Type III (Fe/Zn5) Concrete Vertigo (Wedge-Bolt OT) Component Component Material Anchor Body Case Hardened 10821 Carbon Steel Zinc Plating ASTM 8633, SC1,Type Ill (Fe/Zn 5) www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 ?owers FASTENERS PRODUCT INFORMATION VertigoTM PERFORMANCE DATA Steel Vertigo - Ultimate Tension Load Capacities when Installed in Minimum ASTM A 36 Steel (Beams) and ASTM A 572 Steel (Purlins)12 Anchor Size! _____________ ____________ Minimum Steel Gauge (Thickness) 20 18 16 14 12 3/16" 1/4" Rod Diameter Mount Screw Shank in. Direction Size and Length 0.036" 0.048" 0.060" 0.075" 0.105" 0.187" 0.250" (mm) lbs. lbs. lbs. lbs. lbs. lbs. lbs. N) (kN) (kN) (kN) (kN) (kN) (kN) Vertical 1/4-20x 1" (w/nut) 1.550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 1/4 (6.4) Vertical 1/4-20 x 1 " 405 (1.8) 620 (2.8) 985 (4.4) 1,160 (5.2) 1,560 (7.0) 3,205 (14.4) 5,040 (22.7) Side 1/4-20 x 1" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 - (7,0) (7.0) (8.0) (8.0) (9.2) (17.3) Vertical 1/4-20x 1" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Side 1/4-20x1-1/2"(wijt) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 3/8 (9.5) Vertical 1/4-20 x 1-1/2" 405 (1.8) 620 (2.8) 985 (4.4) 1,160 (5.2) 1,560 (7.0) 3,205 (14.4) - Side 1/4-20x 1-1/2" 405 620 985 1,160 1,560 1,965 (1.B) (2.8) (4.4) (5.2) (7.0) (8.8) - Vertical 1/4-20 x 2" (w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - Vertical 12-20x 1-1/2" 495 710 920 1,560 2,050 3,280 5,040 1/2 (2.20 (3.2) (4.1) (7.0) (9.2) (14.8) (22.7) (12.7) Vertical 12-20x1-1/2"(w/nut) 1,550 1,550 1,775 1,775 2,050 3,850 (7.0) (7.0) (8.0) (8.0) (9.2) (17.3) - 1. For Steel Vertigo loaded perpendicular to threaded rod (shear) the ultimate load capacity for the anchor is 1,965 lbs in nominal 20 gage steel (0.036") Wood Vertigo - Ultimate Tension Load Capacities when Installed in Wood Base Materials (Structural Wood and Timber)1.2 Anchor Size! Rod Diameter Mount Screw Shank Size Embedment Depth __________________ Wood Member (Type) Fir Pine Spruce in. Direction and Length in. (mm) lbs. lbs. lbs. (mm) (kN) (kN) N) 1/4 Vertical 1/4x 1 1 (25.4) 685 (3.1) 650" 650 (2.9) (2.9) (6.4) Side 1/4 x 2" 2 1,510 1,510 1,510 (50.8) (6.8) (6.8) (6.8) Vertical 1/4x 1 1 685 (3.1) 650(25.4) 650 (2.9) (2.9) Side 1/4x 1" 1 685 650 650 (25.4) (3.1) (2.9) (2.9) Vertical 1/4 x 2" 2 (50.8) 1,510 (6.8) 1,510 (6.8) 1,510 (6.8) 3/8 Side 1/4x2" 2 (50.8) 1,800 (8.1) 1,800 (8.1) 1,800 (8.1) (9.5) Vertical " 1/4 x 3 2,075 1,510 1,510 (76.2) (9.3) (6.8) (6.8) Vertical 1/4x4" 4 (101.6) . 2,075 (9.3) 1,510 (6.8) 1,510 (6.8) Vertical 5/16" x 2-1/2" 2-1/2 2,670 3,110 3,110 (63.5) (12.0) (14.0) (14.0) Side 3/8" x2-1/2" 2-1/2 (63.5) 1,450 (6.5) 1,530 (6.9) 1,380 (6.2) 1/2 (12.7) Vertical 5/16' x2-1/2" 2-1/2 (63.5) 2,670 (12.0) 3,110 (14.0) 3,110 (14.0) Truss/joist manufacturers may require pre-drilled holes with wood depending on the location of the anchor installation. Consult with the truss/joist manufacturer for details. Wood Vertigo are recommended to be installed with the Universal Steel & Wood Nut Driver. Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com VertigoTM PRODUCT INFORMATION ?owers FASTENERS IPERFORMANCE DATA Concrete Vertigo - Ultimate Load Capacities when Installed in Normal-Weiaht Concrete' Anchor Size ! ANSI Drill Bit Minimum Concrete Compressive Strength (f c) Embed. Depth psi (13.8 MPa) 4,000 psi (20.7 MPa) 6,000 psi (41.4 MPa) Rod Diameter Mount Screw Shank Size Diameter 111 2,000 in. Direction and Length dbit in. Tension Shear Tension Shear Tension Shear (mm) in. (mm) lbs. lbs. lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) (kN) (kN) 1/4 Vertical (6.4) 1/4"x 1-1/4" 1/4:' 11/4 1,390 1,810 1,950 2,440 2,070 2,570 (31.8) (6.3) (8.1) (8.8) (11.0) (9.3) (11.6) 3/8 Vertical 1/4"x 1-1/2" 1/4" 1-1/2 1,760 2,580 2,595 2,640 2,770 2,700 (9.5) (38.1) (7.9) (11.6) (11.7) (11.9) (12.5) (12.2) 1/2 (12.7) Vertical 3/8"x2-3/4" 3/8" 2-3/4 (69.9) 5,320 (23.9) 5,250 (23.6) 6,050 (27.2) 6,330 (28.5) 8,620 (38.8) 7,410 (33.0) The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. Linear interpolation may be used to determine ultimate loads for intermediate compressive strengths. Concrete Vertigo - Ultimate Load Capacities when Installed Through Metal Deck into Structural Lightweight Concrete 1.73.4 Lightweight Concrete Over Minimum 20 Ga. Metal Deck Anchor Size! Rod Diameter Embedment Depth f'c ~!! 3,000 psi (20.7 MPa) 4 1/2" Wide Deck hv Minimum d Tension Load at 45" in. in. (mm) (mm) lbs. lbs. (kN) (kN) 1/4 1-1/4 800 1,140 (6.4) (31.8) (3.6) (5.1) 3/8 1-1/2 1,780 1,500 (9.5) (38.1) (8.0) (6.8) 1/2 2-3/4 3,880 2,920 (12.7) (69.9) (17.5) (13.1) The values listed above are ultimate and allowable load capacities for Vertigo rod hangers installed in sand-lightweight concrete. The metal deck shall be minimum No. 20 gauge thick steel [0.035-inch base metal thickness (0.89 mm)i conforming to ASTM A 653/ A 653M. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. The tabulated load values are for anchors installed with a minimum flute edge distance of 1-1/2-inch. Concrete Vertigo - Ultimate Tension Load Capacities when Installed in Hollow Core Concrete Plank'2 Anchor Size! Rod Diameter Mount Screw Shank Size ANSI Drill Bit Diameter Embedment Depth of Web Center lbs. Center of Core in. Direction and Length d in. lbs. (mm) in. (mm) N) - (kN) 1/4 (6.4) Vertical 1/47x 1-1/4" 1/4" 1-1/4 2,775 (12.3) 1,920 (31.8) (8.5) 3/8 (9.5) Vertical 114"xl-1/2 1/4" 1-1/2 (38.1) 2,570" 3,700 (16.5) (11.4) 1/2 (12.7) Vertical 318"x2-3/4" 3/8" 2-3/4 (69.9) 8,240 (36.7) 3,480 (15.5) Tabulated load values are for anchors installed in 8-inch-thick hollow core plank with minimum compressive strength of 5,000 psi at the time of installation. The 4' x 6' normal-weight concrete members features include 1-1/2" cover above and below cores and a minimum web thickness of 1-1/2". The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 ?owers FASTENERS PRODUCT INFORMATION VertigoTM IPERFORMANCE DATA Steel Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) and Underwriter's Laboratories (UL) Listings for Pipe Hangers' Anchor Size! Maximum UL Minimum FM Minimum Rod Diameter Mount Screw Shank Pipe Size Steel UL Test load Steel FM Test load Cat No. in. Direction Size and Point Style Thickness lbs. Thickness lbs. (mm) Length In. (mm) In. (kN) in. (kN) (mm) (mm) 7158 Vertical 1/4-20x 1" #3 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7184 Side 1/4-20x 1" #3 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7160 Vertical 1/4-20x #3 4 0.060 1,500 0.096 1,475 3/8 1-1/2 (101.6) (1.5) (6.8) (2.4) (6.6) 7186 Side 1/4-20x #3 4 0.060 1,500 0.096 1,475 (9.5) 1-1/2" (101.6) (1.5) (6.8) (2.4) (6.6) 7154 Vertical 12-20x 1-1/2" #5 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7188 Side 1/4-20 x 2" #3 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7201 Side 12-20x 1-1/2" #5 0.060 1,500 0.096 1,475 (101.6) (1.5) (6.8) (2.4) (6.6) 7161 1/2 Vertical 12-20 x 1-1/2" #5 8 0.250 4,050 0.250 3,800 (12.7) (203.2) (6.4) (18.2) 1 (6.4) 1 (17.1) 1. Steel Vertigo anchors are recommended to be installed with the U,,iversal Steel & Wood Nut Driver. For UL and FM listings, Steel Vertigo must be installed with a retaining nut. Wood Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) and Underwriter's Laboratories (UL) Listings for Pipe Hangers' Anchor Size! Rod Diameter Mount Screw Shank Embedment Depth UL Maximum UI Test Load FM Maximum FM Test load Cat No. in. Direction Size and Pipe Size . lbs. Pipe Size lbs. (mm) Length Ifl. (mm) in. (mm) (kN) in. (mm) (kN) 7165 Vertical 1/4 x 2" 2 3 1,050 (50.8) - - (76.2) (4.7) 7170 Side 1/4x 2" 2 3 1,050 (50.8) - - (76.2) (4.7) 7167 Vertical 1/4x3" 3 3 1,050 - - 3/8 (9.5) (76.2) (76.2) (4.7) 7169 Vertical 1/4x4" 4 3 1,050 - - (101.6) (76.2) (4.7) 7162 Vertical 5/16" x2-1/2" 2-1/2 4 1,500 1,475 (63.5) 4 (101.6) (6.8) (101.6) 7156 Side 5/16" x2-1/2" 2-1/2 4 1,500 - - (63.5) (101.6) (6.8) 1. Wood Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. No pre-drilling was done in the wood base materials. Concrete Vertigo - Ultimate Load Capacities for Factory Mutual (FM Global) Listings for Pipe Hangers' Anchor Size! Rod Diameter Mount Screw Shank Size ANSI Drill Bit Diameter Embedment Depth FM Maximum FM Test Load Cat No. in. Direction and dw in. Pipe Size lbs. (mm) Length in. (mm) in. (mm) (kN) 7173 3/8 (9.5) Vertical 1/4" x 1-1/2" 1/4" 1-1/2 4 1,475 (38.1) (101.6) (6.6) 7175 1/2 (12.7) Vertical 3/8"x2-3/4" 3/8" -2-3/4 (69.9) 4 3,800 (203.2) (17.1) I. Tabulated load values are for anchors installed in 8 inch thick hollow core plank with minimum compressive strength of 4,000 psi at the time of installation. The 4' x 6' normal-weight concrete Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 5 ?owers VertigoTM PRODUCT INFORMATION FASTENERS IPERFORMANCE DATA Steel Vertigo - Ultimate Load Capacities for Underwriter's Laboratories (UL) listings - Luminaire' Catalog Number Anchor Size/Rod Dia. In. (mm) Mount Direction Screw Shank Size and Length Point Style Mounting Surface UL Test load (lb.) 7155 1/4 Vertical 1/4-20 x 1 #3 16 Gauge Steel 45 7157 3/8 Vertical 1/4-20 x 2 #3 16 Gauge Steel 45 7158 3/8 Vertical 1/4-20 x 1 #3 16 Gauge Steel 45 7159 3/8 Vertical 1/4-20 x 1-1/2 #3 16 Gauge Steel 45 7160 1/4 Vertical 1/4-20 x 1-1/2 #3 16 Gauge Steel 45 7183 1/4 Side 1/4-20 x 1 #3 16 Gauge Steel 75 7184 3/8 Side 1/4-20 x 1 #3 16 Gauge Steel 75 7186 3/8 Side 1/4-20 x 1-1/2 #3 16 Gauge Steel 75 7188 3/8 Side 1/4-20 x 2 #3 16 Gauge Steel 75 7155 1/4 Vertical 1/4-20x 1 #3 22 Gauge Steel 25 7157 1/4 Vertical 1/4-20x2 #3 22GaugeSteel 25 7158 3/8 Vertical 1/4-20 x 1 #3 22 Gauge Steel 25 7159 3/8 Vertical 1/4-20 x 1-1/2 #3 22 Gauge Steel 25 7160 3/8 Vertical 1/4-20 x 1-1/2 #3 22 Gauge Steel 25 7183 1/4 Side 1/4-20 x 1 #3 22 Gauge Steel 45 7184 3/8 Side 1/4-20 x 1 #3 22 Gauge Steel 45 7186 3/8 Side 1/4-20 x 1-1/2 #3 22 Gauge Steel 45 7188 3/8 Side 1/4-20 x 2 #3 22 Gauge Steel 45 1. Steel Vertigo anchors are recommended to be installed with the Universal Steel & Wood Nut Driver. For UL Luminaire listing, Steel Vertigo does not require a retaining nut. www.powers.com Canada: (905) 673-7295 or (514) 6314216 Powers USA: (800) 524-3244 ?owers FASTENERS PRODUCT INFORMATION VertigoTM ORDERING INFORMATION Steel Vertical Hanger (#3 for Purlins, #5 for Beams) Cat No. Rod Dia. Screw Shank Size and Length Point Style Self Drilling Range Std. Box Std. Ctn. 7155 1/4 1/4"-20x1" #3 0.036" (20 gauge) to 0.188" (3/16") 100 500 7157 3/8" 114"-20x2" #3 100 500 7158 318 1/4"-20 x 1" (w/nut) #3 100 500 7159 3/8" 1/4"-20x1-1/2"(w/nut) #3 100 500 7160 3/8" 1/4"-20x1-1/2" (w/nut) #3 100 500 7152 1/4" 12"-20x1-1/2" #5 0.188"(3/16")to 0.500" (1/2") 100 500 7154 3/8" 12"-20x1-1/2" (w/nut) #5 100 500 7161 1/2" 12"-20x1-1/2"(w/nut) #5 100 500 Steel Side Hanger (#3 for Purlins, #5 for Beams) Cat. No. Rod Dia. Screw Shank Size and Length Point Style Self Drilling Range Std. Box Std. Un. 7183 1/4" 114"-20x1" #3 0.036" (20 gauge) to 0.188' (3/16") 100 500 7184 3/8" 114"-20 x 1" (w/nut) #3 100 500 7186 3/8" 1/4"-20x1-1/2"(w/nut) #3 100 500 7188 3/8" 1/4"-20 x 2" (w/nut) #3 100 500 7200 1/4" 12"-20x1-1/2" #5 0. 188 " (3/16 ") to 0.500" (1/2") 50 300 7201 3/8" 12"-20x 1-1/2" (w/nut)- #5 100 600 Wood Vertical Hanger Cat No. Rod Dia. Screw Shank Size and Length Point Style Pre-Drill Diameter (If Required) Std. Box Std . Ctn. 7163 1/4" 1/4"x2" Type 17 1/8" 100 500 7203 3/8" 1/4"x1" Type 17 100 500 7165 3/8" 1/4"x2" Type 17 100 500 7167 3/8" 1/4"x3" Type 17 100 500 7169 3/8" 1/4"x4" Type 17 100 500 7162 3/8" 5/16" x 2-1/2" Type 17 100 500 7164 1/2" 5/16" x 2-1/2" Type 17 100 500 Wood Side Hanger Cat No. Rod Dia. Screw Shank Size and Length Point Style Pre-Drill Diameter (If Required) Std. Box Std. Ctn. 7185 1/4" 1/4" xl" Type 17 1/8" 100 500 7205 3/8" 1/4" xl" Type 17 100 500 7170 3/8" 1/4" x 2" Type 17 100 500 7156 3/8" 5/16"x2-1/2" Type 17 100 500 Concrete Vertical Hanger Cat. No. Rod Dia. Screw Shank I Size and Length I Thread F Style Pre-Drill Diameter (If Required) Std. Box Std. Ctn. 7171 1/4" 1/4"x1-1/4" I Wedge-Bolt 01 1/4" ANSI 100 500 7173 3/8" F 1/4" x 1-1/2" F Wedge-Bolt 01 1/4" ANSI 100 500 7175 1/2" 1/4" x 2-3/4" I Wedge-Bolt 01 3/8 ANSI 50 250 Drive Sockets and Pole Tool Cat No. Description RPM Std. Box Std. Ctn. 7166 6'-12' Pole Tool (includes three Jaw Chuck) N/A 1 1 7187 Universal Steel & Wood Socket (Red) 500 to 1500 RPM 5 25 7195 1/4" Concrete Socket (Blue) - 5 25 7197 3/8" Concrete Socket (Blue) - 5 25 7198 1/2" Concrete Socket (Blue) - 5 25 Concrete Vertigo Installation Accessories Cat. No. Description Maximum Std. Std. Bit Length Box Ctn. Vertigo Installation Kit: 5864 1/4" and 3/8" Concrete Drive Sockets (Blue) 6" 1 3/4 Universal Steel & Wood Socket (Red) (Sleeve _Assembly _(same _as_Cat#_5874) 5874 Sleeve Assembly (5-3/4") 6" 1 - Cat. No. Description Usable Length Std. Tube wtllo 5866 1/4" x 6" Hex Shank SDS Drill Bit 4" 1 1 1/2 e;f 0 1 - © 2014 Powers Fasteners, Inc. All Rights Reserved. Vertigo is registered trademark of Powers Fasteners, Inc. For the most current product information please Visit www.powers.com e Powers USA: (800) 524-3244 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 7 '/ inch pipe 5 thru 8 inch pipe P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 3/4 thru 4 inch pipe LISTED FOR STEEL/CPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - 203-EX 2551 cij Approval guide - Pipe Hangers OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171 Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION - Per NFPA 13,13R, 13D and CPVC manufacturers instructions. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. 9/08 NFPA 13 PIPE ROD MAX REC. LOAD LBS. METRIC REFERENCE 3/4 3/8 400 20 1 3/8 400 25 11/4 3/8 400 32 11/2 3/8 400 40 2 3/8 400 50 21/2 3/8 600 65 3 3/8 600 80 31/2 3/8 1 600 4 3/8 1000 100 5 1/2 1250 125 6 1/2 1250 150 1 8 1/2 1250 200 Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. 551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER S MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hunger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/08 -, Can be installed on bar joists or 1-beams Thumb spring retainer allows for ease of positioning Snap-off bolt head helps enable easy installation and inspection of seismic sway braces No assembly required No Loose parts Meets NFPA®-13 requirements for seismic sway bracing Material: Steel c®us <8>0 S H P D APPROVED Part Number Finish Flange Thickness FT A B C csBBARJEG ElectrogaLvanized 1/4" - 1/2' 2' 3' 2 1/2' CSBBARJHD Hot DIP Galvanized 1/4 - 1/2 2 3 2 1/2 UL Loads Brace Direction to Structure Service Pipe Size Rating Parallel 1"_ 10' 3,000 lb 1-12" - 3,740 lb FM Loads brace Uirection Service Pipe Size Horizontal i Capacity ps liisldlldlion Angle from VerticaL * to Structure 30° -44° 45° - 59° 60° - 74° 75° - 90° Parallel N/A 1.410 lb 2,110 lb 2,540 lb 2,830 lb Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Meets NFPA®-13 requirements for seismic sway bracing FT _ H(IL) w --IRS[-- Material: Steel Finish: ELectrogatvanized c®s <zj> OSHPD APPROVED Part Number FT Flange Thickness Rod Size RS Height H Width W CSBBC075EG 1/4" - 3/4" 1/2' 2 1/2" 23/4" DL Lond Brace Direction to Structure Service Pipe Size Rating Parallel 1" - 4' 1,200 lb Perpendicular 1" - K' 2,015 lb FM Loads Brace Direction to Structure i Service Pipe Size . Horizontal Capacity per Installation Angie from Vertical 30 44 45 59 60 741 75 90 Parallel N/A 1,190 to 1,680 lb 1,160 lb 1,280 lb Perpendicular N/A 1,620 lb 1,710 to 1,010 lb 1,110 lb FM is a registered certification mark of FM Approvals LLC. LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL, UP, cUL, cUR, cULus and cuRus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.peritair.com and from your Pentair customer service representative. Improper installation, misuse, misapplicaticn or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warrant'i. © 2017 Pentair All rights reserved Pentair, CADDY, CADWELD, CRITEc, ERICO, ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to Change specifications without prior notice. (I' +PENTAIR Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Use for both Lateral and Longitudinal sway brace applications Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Center bolt does not require tightening Meets NFPA-13 requirements for seismic sway bracing -4- Material: Steel C&US <8> OSHPD APPROVED Part Number * Finish Hole Size HS A B C CSBUNIV050EG Electrogalvanized 9/16' 5 1/4" 4" 1 5/8' CSBUNIV075EG ElectrogaLvanized 13/16' 5 1/4" 4" 1 5/8" CSBUNIV05OHD Hot-Dip Galvanized 9/16" 5 1/4' 4" 1 5/8" UL Loads Brace Type Service Pipe Size Rating Pipe 1"- 10" 3.000 lb 1/4' Thick Angle 1" -8" 2,015 lb FM Loads Hui izoiilal Capacity per Installation Angle from Vertical Brace Type Service Pipe Size 1 The Quick Grip Lateral Brace, part of the CADDY Line of fire sprinkler bracing systems from Pentair, is designed to help simplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design for quick attachment of brace pipe to service pipe saving time and money. Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4 (25 mm and 32 mm) brace pipes to reduce inventory Yellow tips provide a visual indicator that the bolts have been property torqued Easy installation with an impact wrench from the bottom side of the clamp Meets NFPAa_13 requirements for seismic sway bracing Material: Steel Finish: ELectrogaLvanized C&US <~ ED OSHPD APPROV Part Number Pipe Size Height H Width CSBQG0250EG 2 1/2' 5 7/16" —57/8" 6 3/4" CSBQG0300EG 3" 6 1/8" —6 1/2" 7 1/2" CSBQG0400EG 4' 7 1/8" —71/2" 8 3/4" CSBQ60600EG 6" 9 1/4' —9 5/8" 11 3/4" CSBQG0800EG 8" 11 3/8" —11 13/16" 13 7/8" UL Loads Port Number fl" 5i vk,e ripe Schedule ' "' "•• 1" Brace Pipe 1 1/4" Brace Pipe Dyna-Flow® 2,015 lb 2,015 lb UL Loads Part Number Service Pipe Schedule Lateral 1 Brace Pipe 1 1/4' Brace Pipe CSBQG0600EO Maps-Flow 2.015 lb 2.015 Lb 10 2,015 lb 2,015 lb 40 2.015 lb 2.015 lb CSB000800EG 10 2.015 lb 2,015 lb 40 2,015 lb 2.015 lb - FM Loads Part Number Service PipeScheduLe Lateral Horizontal Capacity per Installation Angie from Vertical 30 44 45 59 60 74 75 90 LightwalL 1,410 lb 2,000 lb 2,450 lb 2,740 lb CSBQG0250EG 10 1,410 lb 2.000 lb 2,450 lb 2.740 lb 40 1,410 lb 2,000 lb 2.450 lb 2,740 lb Lightwall 1,190 lb 1,680 lb 2,060 lb 2,300 lb CSB060300EG 10 1,190 lb 1,680 lb 2,060 Lb 2.300 lb 40 1,190 lb 1.680 Lb 2.060 lb 2,300 lb CSBQG0400EG Lightwall 1,190 lb 1,680 lb 2,060 lb 2,300 lb 10 1.190 lb 1,680 lb 2,060 lb 2,300 lb 40 1,190 lb 1.680 lb 2,060 lb 2,300 lb Ljghtwpll ,870 lb 1,230 lb 1,510 lb 1,690 lb CSB060600EG 10 870(b 1,230 lb 1,510 lb 1,690 lb 40 970 Lb 1,370 lb 1,680 lb 1,870 lb CSB000800EG 0.188(Wall 1 hicknessl 790 lb 1,110 lb 1.360 lb 1,520 lb 40 790 Lb 1,110 lb 1,360 lb 1,520 lb Use for both taterat and longitudinal sway brace applications Snap-off boLt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2 brace pipes and 1/4' angle iron braces to reduce inventory Slotted design grabs service pipe for added gripping strength Meets NFPA®-13 requirements for seismic sway bracing Material: Steel c®us <> OSHPD APPROVED PrtNumber j PrpeSize A H - CSBSTU0100EG 1" 6 7/8 1" CSBSTUO125EG 1 1/4 73/8 1 CSBSTUO150EG 1 1/2 73/4 1" CSBSTU0200EG 2 8 1/8 13/16" CSBSTU0250EG 2 1/2 8 7/8 1 3/16 CSBSTU0300EG 3 93/8 1 3/16 CSBSTU0400EG 4' 10 5/8' 1 1/2 CSBSTU0500EG 1 " 12 1/8' 1 1 1/2' CSBSTU0600EG 6" 13 5/8" 2' CSBSTU0800EG 8 15 3/4 2 CSBSTU1000EG 10" 18" 2" li1th1 II1 CSBSTUO100HD 1" 67/8" 1" CSBSTUO125HD 11/4 73/8 1 CSBSTUO15OI-ID 11/2" 73/4" 1" CSBSTU0200HD 2 8 1/81, 1 3/16 CSBSTU025OHD 2 1/2" 87/8" 1 3/16' CSBSTU0300HD 3 93/8 1 3/16 CSBSTU0400HD 4" 105/8" 11/2" CSBSTU0500HD 5 121/8 11/2 PENTAIR Part Number Pipe Siz A L...J B CSBSTU0600HD 6 13 5/8 2' CSBSTUO800HD 8' 153/4' 2' CSBSTU1000HD 10" 18 2" UL Loads Listed for Restraints) Part Number ...yna ai® du ,ce Pipe Sch 10 Servi'e ° pe Sch 40 SeWiCe Pipe CSBSTU0100xx N/A 655 lb 655 lb CSBSTU0125sx 655 Lb 655 lb 655 lb CSBSTU0150xx 655 lb 655 Lb 655 Lb UL Loads (Listed for Sway Praces) Lateral Longitudinal Part Number Dyna-F ow® Service Pipe EZ FLOW°° Service Pipe Sch 10 Service Pipe Sch 40 Service Pipe Dyne F oc. F Service Pipe EL FLOWTM Scia ce Pipe FcC 10 Se-vicoP tie Sch 40 Service Pipe CSBSTU0200xx 3.000 lb N/A 3,000 lb 3,000 to N/A N/A N/A N/A CSBSTU0250xa 3.000 lb N/A 3,COIII 5 3,000 lb 2,1. to N/A 2.015 Lb 2.015 lb CSBSTU0300xx 3.000 lb N/A 3,COO lb 3.000 lb 2,015 Lb N/A 2,015 lb 2,015 Lb CSBSTU0400xx 3,000 lb 3,000 lb 3,000 Lb 3,000 lb 2,015 lb N/A 2,015 lb 2.015 lb CSBSTU0500xx N/A 3.000 lb 3,000 lb 3,000 lb N/A N/A 2.015 lb 2.015 Lb CSBSTU0600xx N/A 3.000 lb 3,000 Lb 3,0011 lb N/A 2.015 lb 2,015 to 2,015 lb CSBSTU0800xx N/A N/A 3,000 Lb 3,000 lb N/A N/A 2,015 lb 2,015 lb CSBSTU1000xx N/A N/A 3,000 Lb 3,000 to N/A N/A 3,000 lb 3,000 lb FM Load. (LightwotL. Sch 10 and Sod 00 Service Pipes) Horizontal Capacity per nstaUatior Angle Nom Vertical Part Number Lateral Longitudinal 30° - .4° 45° - 59° 60° 74° 75 90° 3Y - 44 - 59° 60-- 74° 750 -900 CSBSTUO100xx 860 Lb 1.220 lb 1,500 Lb 1,670 lb 970 Lb 720 lb 860 lb 960 lb CSBSTU0125xx 860W 1,220 lb 1,500 Lb 1,670 lb 970 lb 720 lb 860 lb 960 lb CSBSTU0150xa 860 Lb 1.220 Lb 1,500 lb 1.670 Lb 970 Lb 720 Lb 860 lb 960 lb CSBSTU0200xx 1.530 Lb 2,160 lb 2.650 Lb 2,960 lb 870 Lb 690 Lb 830 lb 930 lb CSBSTU0250xx 1.530 Lb 2,160 lb 2,650 Lb 2,960 lb 870 Lb 690 Lb 830 lb 930 lb CSBSTU0300xx 1,530 (b 2,160 lb 2,650 Lb 2,960 lb 870 Lb 6901b 830 lb 930 lb CSBSTUO400xx 1.570 Lb 2,220 Lb 2,720 lb 3.030 lb 1,550 Lb 1,390 Lb 1,680 lb 1,870 lb CSBSTUO500xx 1,570 lb 2.220 lb 2,720 Lb 3,030 lb 1,550 lb 1,390 lb 1,680 lb 1,870 lb CSBSTUO600xx 1.980 lb 2.810 lb 3,440 Lb 3,840 lb 1,470 lb 1,170 lb 1,410 lb 1,570 lb FM Loads 0.188" watt and Sch 40 Service Pipes) I zori ta Capacity r r I ri I ia n Ar gte from Vertical Part Number Lateral Longitudinal - 30°-44° 45°-59° 60-/a /5 90° 30 44 45°-59° u0°-7. 75°-90° CSBSTU0800xx 2,040 b 2,890 Lb 3,540W 3,950 lb 1,200 lb 1,700 lb 2.090 Lb 2.330 Lb CSBSTU1000xx 2,040 b 2,890 lb 3,54101.1b 3,950 lb 1.200 lb 1.700 lb 2.090 lb 2.330 lb a ___ PENTAIR FireLock® FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. - Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Red Enamel in EMEA-l. Optional: Hot dipped galvanized. FireLoW Fittings GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009V/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings FLOW DATA Frictional Resistance F77 _r 1 ¼ 1.660 1,5 0.8 3.7 1.5 32 42.4 -1 0.5 0.2 1.1 0.5 1½ 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1,3 0.7 3.3 1.3 761 mm 3.000 4.5 2.3 11.0 4,5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108 mm 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 - 1,3 6.4 2.6 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 ' 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 1 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS FireLock® Fittings 1 0.03 DIMENSIONS C to E C W-_- T c lb to NO. 003 NO. 002 NO. 006 No. 001 90' Elbow N 45 Elbow 003 1 j• 1¼ 1,660 08 03 32 42.4 - - - 21 01 1 ½ 40 1.900 48,3 - - - J - - - - - - - - - 0.82 21 04 0.2 2 2.375 275 17 200 18 275 24 088 06 - cn 603 - 70 08 51 08 70 1,1 22 * 03 292 2.875 300 31 225 22 3.00 3.6 088 10 65 730 3000 76 1 300 330 57 225 10 24 76 1.6 22 0.5 76.1 mm 751 76 1.5 57 1.1 - - - 3 3.500 338 4.0 2.50 3.1 3,38 5.3 0.88 1.2 80 88.9 86 1.8 64 1,4 86 2.4 22 0.5 108mm 4,250 4.00 5.7 3.00 5.1 4.00 7,5 108.0 102 2.6 75 2.3 102 3.4 - - 4 4.500 4.00 6.7 - 3.00 5.5 4.00 8,7 1,00 2.4 100 114,3 102 3.0 76 2.5 102 3.9 .. 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 mm 5.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18,3 3.50 11.7 5.50 22.7 1.00. 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 - 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 e V -- ,m jOM crt:iM TONG ,: •i; -.iC i" it: Jit jTC :2fri ,01C i:t4.3 1L iCi' T, -n-' ;0 1Rt-: NoI I wvklng ei Dimencsm1n mnen ri II Hi -Size mm L 1 25 33.1 500 102 45 .71' 1.327 2.362. 4.016' 1.172 32 42A 2MI0e45 70 '106' 44 lii 1.669 .45 4.1137 1.332 43 48.3" 500 ITle " 1,900(? D1145 2,874,7 2.914,7 34i52 1.732 73' 108 44'- 44 2-Ml0e55 83 122 45 2 2.245 3.45 3.268 4.803- 1.732 "?;50- 60.3 500 2 87 123 44U 2,375 3-45 3,425 4.843 .. ' 1732 65 73.0 2-M10x55 , 100 138 44 2.815 3.45 3.937 - 5.433 1.132 365 761 7L3 -'500 2 M10x55 103 ,-- '142 4530 j' 3.000 2J - 80 8&9- 500 2- M1- 117 166 45 '3 3.800 - 3.45 ' 4.906 6.535' 1.712 ,i100 , 7 1080..."-500 2-M12x65 .. 131.. j'0$$3 48; 4 - 4.250 3.45 5.302 7.401 1.889 100 114.3 500 2-Ml2x65 139 . '190' 49 4 4.500 3.45 5.472 7.480 1.929 - 125 . 133.0 - 400 163 210,, 49 5.250 ) p2.75 2-M12iO5 '6.4hz z"8.268' 1.929 125' . 139.1 - 4 2 M1275 218 . 49 S . 5.500 2.15 6.614 8.583 1.929 159.0' 400 2- 192 4: 1242' 49U 6.250 - -'2.75 T 7.559 -9.528 1929 00 400 50-j t 150 165.1 2 M12x15 193 241 49 '6 6.500 2.15 1588 9.488 1.939. 150' . 168.3. , -- 19a5 -2491 6 6.625'- 2,75 - - 7.815 9.003 . 1.969 -8'8.625 1 200 219.1 300 lio 2-MI6 253 ' 320' 59)65 250213" 300 -. 335 426,.. 60 10.148 ' 2.97 2-M22030 13.189 116.772' 2.611 300 - 2 M22x130 ' 380 7410 65. 12 _-12.752 2.07 14.96 18.504 2.559 e117,i.: 'i ... .is.).....' rIRH r1 j...- -iS... 1 0j1Ot' (4V 5'.7tI ffO1 (Jro - 1TOt49 ,; tot' .o'Rjaid-Couotina - - 5U04 .I. icP iC0 1 L4 ØC3 rrO' jrC4 1tS)0G ;.11L 0ti.Xxf cJTON ; i3 10\r,zo oG Wit TO\ 1C TO .FIexibIeCoupIing.-- KY' jçe". ;O toO : .0gc:: f4C'VCy-4G 'G j) ;al, 1 P OD 0 PSU'4P No-Sre I foam fi1 T1 -, XO _(,f NO : NG t1C Do ;.;, -- ;:j1C° ;rJt'3 N JNI tY' pTCMG : Nothtol Anvil Item Numbsizeer ' UiivesoI WorkinNumberg Dimensions Approx. Pressure Wt. Each In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 800000002 CB90033 300 1.50 1.50 0.84 25 2065 3810 38.10 0.38 1¼ 800000010 CB90044 300 1.75 1.75 1.34 32 2065 44.45 44.45 0.6/ 1½ 800000028 CB90055 300 1.94 1.94 1.80 40 2065 49.27 49.27 0.82 2 800000036 CB90066 300 2.25 2.25 2.90 50 2065 57.15 57.15 1.32 214 800000044 (890077 300 2.70 2.70 4.75 65 1 2065 68.58 68.58 2/5 Ti A L IN5Ji...Star Fire Products Division of Anvil International Cast Iron - Class 125 Fittings Submittal Sheet MATE RIAL 1:11SPECIFICATIOMS UL F Cast iron threaded fittings are UL & ULC Listed & Dimensions conform to ANSI Bi 6.4 Class 125. APPROVED Factory Mutual Approved for 300 psi service. Threads are NPT per ANSI/ASME Bl .20.1. For Listing/Approval details contact your Gray iron per ASTM Al 26 Class B. AnvilStar Representative. IPROJECT .INFORMATION: APPROVAL STAMP: I Project: Date: Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For the latest (JL/IJLC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06-001 go to www.anvilstar.com or contact your local AnvilStar representative Star- Fire Products Division of Anvil* International Cast Iron - Class 125 Fittings Submittal Sheet :1 •lulslhl[rl.I.11 :J!Ik1Ec Nominal Anvil Item Number Universal Working Max.Dimensions Approx. Size Number Pressure A Ewh In. (mm) PS! (Val In. (mm) Lbs. (ki) 1 x 1h 800007742 CRC031 300 1.70 0.62 25x15 2065 1 43.18 0.28 1 53/4 800007759 CRC032 300 1.70 1 43.18 0.80 25x20 2065 0.36 Lj:i:1 ii MATERIAL SPECIFICATIOPJS qW9 Cast iron threaded fittings are UL & ULC Listed & Dimensions conform to ANSI Bi 6.4 Class 125. APPROVED Factory Mutual Approved for 300 psi service. Threads are NPT per ANSI/ASME B 1.20.1. For Listing/Approval details contact your Gray iron per ASTM Al 26 Class B. AnvilStarm Representative. IPROJECT lI IiISRlL'ill[IIil Project: Date: Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06.009 go to www.anvilstar.com or contact your local AnvilStar representative A J' IwtStar Fire Products Division of Anvil* International 49~ Cast Iron - Class 125 Fittings Submittal Sheet :11.1'I' I 1 G 900 ELBOW Nominal I Anvil Item I Universal I Max. Working Dimensions I Approx. Size Number Number Pressure Wt. Each B In (mm) PSI (kPa) In (mm) In (mm) Lbs (kg) 1 x 14 800001042 CB90031 300 1.26 1.36 0.64 25x15 2065 32.00 34.54 0.29 1 x Ii 800001059 CB90032 300 1.31 1.45 0.87 25 ii 20 2065 34.79 36.83 0.39 11/4 X'/2 800001067 CB90041 300 1.34 1.53 0.96 32x15 2065 34.03 38.86 0.44 1 '/4X3/4 800001075 CB90042 300 1.45 1.62 1.13 32x20 2065 36.83 41.14 0.51 11/4 X1 800001083 CB90043 300 1.58 1.67 1.16 32x25 2065 40/3 42.41 0.53 800001091 CB90051 300 1.41 1.66 1.17 40x15 2065 35.8/ 42.16 0.53 11/2 X3/4 800001109 CB90052 300 1.52 1.75 1.28 40x20 2065 38.60 44.45 0.58 1½x1 800001117 CB90053 300 1.65 1.80 1.51 40x25 2065 41.9/ 45.72 0.68 1½x1/4 800001125 CB90054 300 1.82 1.88 1.62 4002 2065 46.22 47.75 0.73 2x½ 800001133 CB90061 300 1.49 1.88 2.00 50x40 2065 37.84 47.75 0.9/ 2x 3/4 800001141 CB90062 300 1.60 1.97 2.05 50x20 2065 40.64 50.03 0.93 2 x 800001158 C1390063 300 1.73 2.02 2.10 50x25 2065 43.94 51,30 0.95 2x1'/4 800001166 CR90064 300 1.90 2.10 2.30 50x32 1 2065 48.26 53.34 1.04 2 x 1½ 800001174 CB90065 300 2.02 2.16 2.60 50x40 2065 51.30 54.86 1.18 MATERIAL SPECIFICATIOMS UL @q f Cast iron threaded fittings are UL & ULC Listed & Dimensions conform to ANSI B] 6.4 Class 125. APPROVED Factory Mutual Approved for 300 psi service. Threads are NPT per ANSI/ASME Bi .20.1. For Listing / Approval details contact your Gray iron per ASTM Al 26 Class B. AnvilStar°' Representative. PROJECT INFORMATION:i Project: Date: Phone: Architect! Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, .IL REV. 03.03.06-003 go to www.anvilstar.com or contact your local AnvilStar representative REDUCI PJG TEE REDUCIPJG TEE Nominal Anvil Item Universal Working Dimensions Approx. Nominal 'Anvil Item Universal' Max. _Dimensions_ ' Approx. Size Number Number Pressure -i-- -(-- WI. Each Size Number Number Pressure 4 B ( Wt. Each In (nrnz) PSI (kPa) (tm) Lbs (kg) In (mm) Lbs (kg) 1 PSI (0a)(aim) (mm) (mm) x ½ x 1 800004244 CT313 300 1.50 1.36 1.50 1.08 1½ x 1½ x 11/4 800004483 C1544 300 1.82 1.75 1.88 2.22 25x 15x25 2065 38.10 34.54 38.10 0.49 40x32x32 2065 46.22 44.45 47.75 1.00 1 5 3/4 x1 800004251 C1323 300 1.50 1.45 1.50 1.18 1½511/4 x1½ 800004491 C7545 300 1.94 1.88 1.94 2.45 25x20x25 2065 38.10 36.83 38.10 0.54 40x32x15 2065 49.27 47.75 49.27 1.11 lxi x½ 800004269 CT331 300 1.26 1.26 1.36 0.95 11/2 x11hx1/2 800004517 C1551 300 1.41 1.41 1.66 1./6 25x25x IS 2065 32.00 1 32.00 1 34.54 0.43 40x40x40 1 2065 35.81 1 35.81 42.16 0.80 lxi x3/4 800004277 (1332 300 17 IT 1.45 .10 11/2 x11hx 3/4 800004525 (1552 300 1.52 1.52 1.75 1.8/ 25 x 25x 20 2065 34.79 34.79 36.83 0.50 40 X 40)120 2065 38.60 38.60 44.45 0.85 11/4 X1 x½ 800004301 CT431 äiö 1.1 T 117 11/2 x11hx1 800004533 CT553 300 1.65 1.65 1.80 1.94 32x25x 15 2065 34.03 3200. 38.86 0.53 40x40x25 2065 41.91 41.91 45.72 1 0.88 11/4 xl x 3/4 800004319 (1432 300 1.45 1.37 1.62 1.38 1½x1½x11/4 800004541 CT554 300 1.82 1.82 1.88 2.29 32x25x20 2065 36.83 34.79 41.14 0.63 4040x32 2065 46.22 46.22 47.75 '104 11/4 5 1 x 1 80000432/ (1433 300 1.58 1.50 1.57 1.47 2 x 1 x 2 800004566 (1636 300 2.25 2.02 2.25 3.40 32x25x25 2065 4013 1 38.10 1 39.87 0.67 50x25x50 2065 57.15 1 51.30 5/15 1.54 11/4 x x 1/4 800004335 (1434 300 1.75 1.67 1.75 1.80 2 x 1/4 x 2 800004574 (1646 300 2.25 2.10 2.25 2.80 3225x32 2065 44.45 42.41 44.45 0.82 50x32x50 2065 57.15 53.34 1 57.15 1.2/ 11/4 x11/4 x 1/2 800004350 (1441 300 1.34 1.34 1.53 1.37 2x11/2 x1/2 800004582 (1651 300 1.49 1.41 1.88 2.09 32x32x 15 2065 34.03 34.03 38.86 0.62 50x40x 15 2065 37.84 35.81 47.75 0.95 11/4 x11/4 x 3/4 800004368 (1442 300 1.45 1.45 1.62 1.54 2x11/2 x3/4 800004590 (1652 300 1.60 1.52 iT 2.40 32x32x20 2065 36.83 36.83 41.14 0.70 50x40x20 2065 40.64 38.60 50.03 1.09 ]1/4 X 11/4 x 1 800004316 (1443 300 1.58 1.58 1.67 1.65 2 x 11/ x 1 800004608 (1653 300 1.73 1.65 2.02 2.54 32x3225 2065 40.13 1 40.13 1 42.41 0.75 50x40x25 2065 43.94 41.91 51.30 1.15 1½x1 x½ 800004400 (1531 300 1.41 1.34 1.66 1.41 2x1½x11/4 800004616 (1654 300 1.90 1.82 2.10 2.85 40x25x 15 2065 35.81 34.03 42.16 0.64 50x4032 2065 48.26 1 46.22 1 53.34 1.30 1½x1 x 3/4 800004418 (1532 300 1.52 1.37 1.75 1.65 2x1½x11h 800004624 (1655 300 1.49 1.41 1.88 2.24 40x25x20 I 2065 3860 34.79 44.45 0.75 50x40x40 2065 37.84 35.81 47.75 1.02 1½ x 1 x 1 800004426 (1533 300 1.65 1.50 1.80 1.65 2 x 1½ x2 800004632 (1656 300 2.25 2.16 2.25 3./5 40x25x25 2065 41.91 38.10 45.72 0.75 50x40x50 2065 57.15 54.86 5/15 1.70 1½x1 x11/4 800004434 (1534 300 1.82 1.6/ 1.88 2.00 2x2x1/2 800004640 (1661 300 1.49 1T49 1.88 2.60 40x2532 2065 46.22 42.41 47.75 0.91 50x50x15 2065 37.84 37.84 47.75 1 1.18 1½x1 x 1½ 800004442 (1535 300 1.94 1.8 1.94 2.30 2x2x 3/4 800004651 (1662 300 1.60 1.60 1.97 2.71 40x25x40 2065 49.27 1 45.72 49.27 1.04 50x50x20 2065 40.64 1 40.64 5003 1.23 1½ 5 11/4 x 1/2 800004459 (1541 300 1.41 1.34 1.66 1.58 2 x 2 xl 800004665 CT663 300 1.73 1.73 2.02 2.9/ 40x32x15 I 2065 35.81 34.03 42.16 0.72 1 50x5015 2065 43.94 43.94 51.30 1.35 1½ x11/4 5 3/4 800004467 (T542 300 1.52 1.45 1.75 1.72 2X2x11/4 800004673 (T664 300 1.90 1.90 2.10 3.32 4002x20 2065 38.60 36.83 44.45 0.78 5050x32 2065 48.26 48.26 53.34 1.51 1½x11/4 x1 8000044/5 (1543 300 1.65 1.58 1.80 1.85 2x2x11h 800004681 (T665 300 2.02 2.02 2.16 3.72 4032x25 2065 41.91 15.72 0.84 1 50x50x40 _ 2065 1 51.30 1 51.30 54.86 1 1.69 IN5itLStar- Fire Products Division of Anvil* International E RNVIL Cast Iron - Class 125 Fittings Submittal Sheet MATERIAL SPECIFICATIOWS UL @q Cast iron threaded fittings are UL & ULC Listed & Dimensions conform to ANSI Bi 6.4 Class 125. APPROVED Factor" Mutual Approved for 300 psi service. Threads are NPT per ANSI/ASME B 1.20.1. ' For Listing/Approval details contact your Gray iror per ASTM Al 26 Class B. AnvitStar° Representative. iPROJECT iINFORMATION: APPROVAL STAMP: l Project: Date: Phone: Architect .' Engineer: Contracto Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For the latest UL/IJLC Listed and FM Approved pressure ratings, versus pipe schedule, (jir#' REV 03.03.06-005 go to www.anvitstar.com or contact your local AnvilStar representative A —i-- A -i-] it Star- Fire Products Division of Anvil International Cast Iron - Class 125 Fittings Submittal Sheet STRAIGHT TEE Nominal Anvil Item Number UfliVCJ5OI Max Dimensions Working Approx 1. Each Size Pressure Number A In. (mm) PSI kPa) In. (mm) In. (mm) Lbs. (kg) 1 800003204 (1333 300 1.50 1.50 1.21 25 2065 38/0 38/0 0,55 ]1/4 800003212 (1444 300 1.75 1.75 1.87 32 2065 44.45 44.45 0.85 11/2 800003220 (1555 300 1.94 1.94 2.51 40 2065 49.27 49.27 1.14 2 800003238 (1666 300 2.25 2.25 3.96 50 ____ ___ 2065 57.15 57/5 1.80 2½ 800003246 CT777 300 2.70 2.70 6.45 65 2065 68.58 68.58 1 2.93 MATERIAL SPECIFICATIOWS Cost iron threaded fittings are UL & ULC Listed & Dimensions conform to ANSI Bi 6.4 Class 125. APPROVED Factory Mutual Approved for 300 psi service. Threads are NPT per ANSI/ASME B 1.20.1. For Listing /Approval details contact your Gray iron per ASTM Al 26 Class B. AnvilStarTM Representative. PROJECT iINFORMATI ON: APPROVAL STAMP: I Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For the latest UL/IJLC Listed and FM Approved pressure ratings, versus pipe schedule, REV 03.03.06.004 go to www.anvilstar.com or contact your local Any//Star representative A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has a Pressure Rating of 300 psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-i 35 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS ir ir irii :• 1 1.461 1.083 70 .. 11/4 2.070 1.418 51 11/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 11/4 1.00 .- - -- -------- 11/2 - 1.00 2 100 - ------ --- ........ * Eddyfhread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, 6 Chesterfield, MO 63017 contact your salesperson today at c®uS ,' BULL MOOSE TUBE COMPANY (800) 325-4467 (800) 325-4467 or (636) 537-2600 LISTED 0 FAX: (636) 537-2645 in the USA, or from Canada ______ www.bullmoosetube.com call (800) 882-4666 A company e-mail:sa1es@bu11moosetube.com <i > APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. Schedule 10 Pipe iL IL "oo ir 1 1 1.315 1.097 1.41 lbs/ft 91 11/4 1.660 1.442 . 1.81 lbs/ft ' 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 434 lbs/ft 19 4 - 4.500 4.260 JL 562 lbs/ft 19 Schedule 40 Pipe I O@& 0 ft L 1 ft '"- I 1 1 315 1.049 1.68 lbs/ft 70 11/4 . 1.660 1.380 2.27 lbs/ft 51 1.1J? 1.900 . 1.610 2.72 lbs/ft 44 .2 2.375 2.067 . ..................... 3.66... lbs/ft .. ............ 30 2 1/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 - 3.068 7.58 lbs/ft 19 4 - * 4.500 4.026 - J - 10,80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. . _.. ...... ......... . ........... ......: . ... .... ... (1819 Clarkson Road For additional information, u A Chesterfield, MO 63017 contact your salesperson c L US BULL MOOSE TUBE COMPANY (800) 3254467 today at (800) 325-4467 or LISTED FAX: (636) 537-2645 (636) 537-2600 in the USA, ______ www.bullmoosetube.com or from Canada FM> ACfl.V company e-mail: sa1es(.bu11moosetube.com call (800) 882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 Specifications Size : 21/2",3",4",6" Working Pressure : 300 psi (21.5 Bars) Test Pressure : 600 psi (43.0 Bars) Working Temperature : —250 F (- 120c) Factory Installed UL Approved Tempered Switch for Indoor and Outdoor Use Materials Body : Ductile Iron, Nylon-il Coated Disc : AL-Bronze, Ductile Iron, EPDM Encapsulated Stem : Stainless Steel, Hardened & Tempered Housing : Ductile Iron (ASTM A-536) Hand Wheel Ductile Iron (ASTM A-536) Dimensions (Unit: mnnch) ISJZeIA 8 C I) E 1 F C UI 2112"118.8(4.48) 444)1751 1078)424j!3L)(2.88 120815.48) 990(3.05)1050)41311050(391) 3" 1203)4.73) 44.4(175) I107.8(42t)071(35J 1463576)_99.0)3.05)105.0)4.13)105.0(3.94) 4 1455(5.13) 444(175)1078)424) 675) L1143111(4.50~1715 99.013.4811050(413)105013941 6 179.5(7.07) 53.5(Z11)11470(5.19)5.B3 214.5'8451 1991)4) 1239149911050(5.05) Indoor and Outdoor Use UL ULC Listed and FM Approved 0 Y7 Y1 L11L UL ULC Listed & FM Approved Specifications Size :2,2 1/2°, 3°. 4!'& 6° Working Pressure : 300 psi (21.5 Bars) Test Pressure : 600 psi (43.0 Bars) Working Temperature : - 250°F(- 120°C) Install in Both Horizontal or Vertical Position Materials Body . : Ductile Iron (ASTM A-536) Seat Ring : Brass (ASTM C37700) Clapper : Stainless Steel (ASTM A-240-304) Rubber Ring : EPDM Srping : Stainless Steel (ASTM A-240-304) Hinge Pin : Stainless Steel (ASTM A-240-304) Flow Duelo Friction Loss Curves Friction Loss Grooved Check Valve( Water at 65°F) 90 C/) 8.0 7,0 - 69 so I :: 29 Q, IS 2 1.0 ,. 09 0.8 t4 0.7 0. 0.6 03 Z 100 200 300 400 500 700 1000 2000 3000 Flow rate in gallons per minute (GPM) Dimensions unit inch (mm), Lb (Kg) SIZE 00 'A B C 0 Dia E Da F Wt tLbfkg) 2.37(60.3) .6.34(161.0) 3.54(90.0) 2.80 (71.0) 5.02 (127.5) 2.37 (60.3) 4.21 (107.0) 6.24(2.83) 21/2" 2.87 (73.0) 7.06 (179.4) 3.91 (99.4) 3.19 (81.0) 5.71 (145.1) 2.87 (73.0) 6.74 (120.3) 8.80 (4.00) 3.51 (89.1) 7.80 (18.0) i.29 (109.0) 3,61 (91.) 6.44 (163.6) 3.51 (89.1) 5.24 (133.0) 13.23 (6.00) 4.50 (114.3) 8.62 (218.9) '4.06 (103.1) 425 (108.0) 7.71 (195.9) 4.50 (114.3) 6.49 (164.8) 1 19.84 (9.00) 6" 6.63 (168.3) 10.38(263.6) 5.12 (130.0) 5.43 (137.9) 9.561242.9) 6.63(1681) 8 an (7n37) I q7 419 (17 fill) Grooved Resilient Swing Check Valve (H84X), UL Listed H84X CIO- Connection Ends: Groove to AMA C606 Working Pressure: 300PSI 200PSI and 250PS1 available upon request Temperature Range: 0°C- 80°C Coating: Fusion Bonded Epoxy Coating in accordance with ANSI/AWiNA C550 or painting upon request American Valves I 27 MATERIAL SPECIFICATION Part No. Part Standard Specification Options I Valve Body ASTM A536, 65-45-12 2 Hinge Pin AISI 420 3 Spring AISI 304 AJSt3I6 4 Eye Bet Carbon Steel Zinc Plated 5 Disc DN50-100 AISI 304 DN150-300 ASTMA536,65-45-12 POSt 304 6 Disc Sealing Ring EPDM 7 Seat Ring ASTM B62 C83600 (Pressed Fill AISI 304, AISI 316 Pressed Fit or Threaded Plug Malleable Iron Galvanized Bronze ASTM 5584 9 Plug Malleable Iron Galvanized Bronze ASTM B584 tO Plug Malleable Iron Galvanized Bronze ASTM 6584 11 Plug Malleable Iron Galvanized Bronze ASTM 9594 12 Bob AISI 304 AISI 316 13 Washer AISI 304 AISI 316 14 Nut AISI 304 AISI 316 Note: For special material request other than standard specificaton, please indicate cteady on the inquiry or ardor list. DN Dimensions(mm) Inch mm L Dl D2 B C 2" 58 Ill 57.15 60.3 7.93 15.88 25" 65 184 69.09 73 7.93 15.88 3' 80 197 84.94 88.9 7.93 15.88 4" 100 210 110.08 114.3 8.53 15.88 5 125 246 137.03 141.3 9.53 15.88 6" 150 324 163.96 168.3 9.53 15.88 8' 200 371 214.4 219.1 11.13 19.05 10" 250 457 208.28 273 12.7 19.05 12" 300 535 318.29 323.9 12.7 19.05 r t,vI Si sec SSM/SSV Series Alarm Bells System Sensor's SSM and SSV series alarm bells are low current, high decibel notification appliances for use in fire and burglary systems or other signaling applications. Features 'Approved for indoor and outdoor use Low current draw High dBoutput Available in six-inch, eight-inch, and ten-inch sizes AC and DC models DC models polarized for use with supervision circuitry Mount directly to standard four-inch square electrical box indoors SSM and SSV series come pre-wired Reliable Performance.The SSM and SSV series provide loud resonant tones. The SSM series opeates on 24VDC and are motor driven, while the SSV series operates on 120VAC utilizing a vibrating mechanism. Simplified Installation. For indcor use, the SSM and SSV series mount to a standard four-inch square electrical box. or outdoor applications, weatherproof back bo<, model number WBB, is used. The SSM and SSV series come pre-wired, to reduce installation time. The SSM series incorpora:es a polar zed electrical design for use with supervision circuitry. Agency Listings & LISTED @ ~' 0 MEA APPROVED approved 54011 C5549 3005255 7135-1553.217 331-01-E SSM/SSV Specifications Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 678710 (specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi-flush mounting. Outdoor surface mounted installations shall be weatherproof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4 square electrical box having a maximum projection of 21/2 . Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal, and approved by Factory Mutual and MEA. Operating Temperature Range —31°F to 140°F Operating Voltage SSM series: 24 VDC SSV series: 120 VAC Termination Provided with 2 sets of leads for in/out wiring Service Use Fire Alarm, General Signaling, Burglar Alarm Warranty 3 years Model Gong Diameter Nominal Voltage Operating Voltage Maximum Current Sound Output (dBA) (inches) Limit 55M24-6 6 Regulated 24VDC 16to33VDC DC-31.1 rn/V FWR-53.5mA 82 55M24-8 8 Regulated 24VDC 16 to 33VDC DC-31.1 rn/V FWR-53.5mA 80 SSM24-10 10 Regulated 24VDC 16 to 33VDC DC-31.1 mW F\NR-53.5mA 81 SSV12O-6 6 Regulated 120VAC 96 to 132VAC 53mA 85 SSV12O-8 8 Regulated 120VAC 96to132VAC 53mA 82 SSV12O-10 10 Regulated 120VAC 96to132VAC 53mA 82 Sound output measured at Underwriter Laboratories, as specified in UL464 Ordering Information JWiITI . 55M24-6 55M24-6A Bell, 6 24VDC, Polarized, 82dBA SSM24-8 SSM24-8A Bell, 8, 24VDC, Polarized, 80dBA SSM24-10 SSM24-1OA Bell, 10 24VDC, Polarized, 81 dBA 55V120-6 SSV120-6A Bell, 6', 12OVAC, 85dBA SSV12O-8 SSV12O-8A Bell, 8', 120 VAC, 82dBA 55V120-10 SSV120-10A Bell, 10", 120VAC,82dBA WBB Weatherproof back box for SSM and SSV series, when installed outdoors 02011 Systern Sensor. 3825 Ohio Avenue. St. Charles, IL 60174 Product spedfications subject to change %vithout notice, Visit systemsensokorn to, Phone: 800-SENSOR2 . Fax: 630-377-6495 ou nent product information, induding the lat~t wslon of this data sheet. 14 WFD Series Waterfiow Detector The System Sensor WFD series is compatible with schedule 10 through 40 steel pipe, sizes 2"through 8' and can be mounted in a vertical or horizon ta/position. Features Two-inch mounting hole provided in new WFD30-2 models UL-listed models are NEMA 4 rated Sealed retard mechanism immune to dust and other contaminants -Visual switch activation Field-replaceable retard mechanism and SPDT switches Rugged, dual SPDT switches enclosed in a durable terminal block Accommodates up to 12 AWG wire Designed for both indoor and outdoor use 100 percent synchronization activates both alarm panel and local bell Tamper-resistant cover screws Agency Listings & @ 0 MEA <j~> LISTED pproved APPROVED 5739 C5169 7770-1653:114 67-93-0 3006195 Robust Construction. The WED series consists of a rugged, NEMA 4-rated enclosure. Designed for both indoor aid outdoor use, the WED series operates across a wide temperature range, from 32'F to 120°F Reliable Performance. UL-listed models are equipped with tamper-resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block to assure reliable performance. False Alarm Immunity. The WED series incorpora:es a mechanical retard feature, which minimizes the risk of false alarm due to pressure surges or air trapped in the sprinkler system. In addition, the mechanical retard's uniqLe sealed design is immune to dust and other contaminants. Simplified Operation. The WED series is designed to simplify installation. Two conduit openings permit easy attaciment to the local alarm system. The retard mechanism and dual SPDT switches are field-replaceable. Waterfiow Detector Specifications Vane-type waterfiow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upfiow or horizontal run, at least 6-from any fittings that may change water direction, flow rate, or pipe diameter or no closer than 24 from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psiE for 2-- 8 pipes. The detector shall respond to waterflow in the specified direction after a preset time delay that is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation, The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances fcr standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use. ..'- H Static Pressure Rating 450 P51K Operating Temperature Range 32°F to 120°F (0°C to 49°C) Maximum Surge 18 Feet Per Second (FPS) Enclosure Rating* NEMA 4 - suitable for indoor/outdoor use Triggering Threshold 4-10 GPM Cover Tamper Switch Standard with ULC models, optional for UL Bandwidth (Flow Rate) models, part no. 546-7000 Conduit Entrances Two openings for ½" conduit. Service Use Automatic Sprinkler: NFPA-1 3 One open, one knock-out type One orTwo Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Contact Ratings Two sets of SPDT (Form C) U.S. Patent Numbers 5,213,205 10.0 A, ½ HP © 125/250 VAC 2.5 A@6/12/24VDC Compatible Pipe Steel water pipe, schedule 10 through 40 Warranty 3 Years WFD Field Wiring Diagram Delay Adjustment Dial Overall Dimensions, Installed UI-LISTED SSMD4.X NOTE: COMMON AND B-NO I- CONNECTIONSWILLCLOSE COMPATIBI.E 5S5120-X \.,,, WHEN VANE IS DEFLECTED. I.E., CONTROL PANEL WHEN WATER IS FLOVV1NG. DUAL SWITCHES PERMIT APPLICATIONS TO BE COMBINED POWER 24VDC OR _______________ ON SINGLE DEIECTOD. _______________ - UbOR flAt OWVDC -WFM I WFDDS I S.B IWFD5OI CONTACT RATINGS Iwc000-,I Sr IWErleol or I IlBETSUVAcO IHAMPS RESISTOR I WElDS I 5.7' IWED8OI br I IATI Loop - SCHEMATIC OF 58 °SUGGTEL I ED '/DC E5AMPS I INDIVIDUAL I-iiiI Pipe 0 NO BREAK WIRE AS rl flUddlo SWITCH IN 'NO WATERFIOW CONDITION SUPERVISION OF I IOA I SHOWN FOR CONNECTION. DO DUne NOT ALLOW P10000 STRIPPED WiRE WS~.Tbl. k} LEADS TO EXTEND BEYOND SWITCH balK RUIXRD11UEIJAV EXCEED OR SDCDUIOS ADJUST HOUSING B Wit— LOOP DO NOT EDO SEDDYTVJRVDJB DOES EDT EXUSDO 00 SECONDS WIRES. SECEDOSIRWVDDCCURVETSF4-SX%. ________________ I •...i,' 'I E." .. .:o:j UL Model ULC Model Pipe Size Hole Size Shipping Weight WFD20 WFD20A 2 11/4" 4.2 lbs. WFD25 WFD25A 21/2- 11/4" 4.3 lbs. WFD30-2 WFD30-2A 3" 2" 4.5 lbs. WFD35 WFD35A 31/2" 11,4" 4.71bs. WFD40 WFD40A 4 2" 5.2 lbs. WFDSO WFDSOA 5" 2" 6.3 lbs. WFD60D WFD60A 6" 2" 6.8 lbs. WFD80° WFD80A 8 2 7.5 lbs. Accessories A3008-00 Retard mechanism A77-01-02 Terminal block 546-7000 Tamper-proof switch kit WFDW Tamper-proof wrench for cover WFDN4 Gasket kit *Maximum pressure rating 400 psi as approved by Factory Mutual TEM Sys 02009 Oyster SensV: 3825 Ohio Avenue. St. Charles, IL 60174 .S'EItI.5'OR Phone: 800-SENSOR2 Fax: 630-377-6495 Eu::esltprSdUctI fSrratIXiOiTdUdIngtheIatestIHrsIoYVfthIsdXtasheet A05-0180-013- 1/09-#1922 Iq The AGF Manufacturing Inc. Model 1011 TESTANDRAIN® matches all the features and benefits of our Model 1000 by providing loth the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. The Model 1011A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). The Model 1011A TESTANDRAIN® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. Available in a full range of sizes from 3/4 to 2 NPT and BSPT, with all specifiable orifice sizes 3/8 (2.8K), 7A6 (4.2K), ½ (5.6K), 17/32fl (8.0K), /8 (11.2K, ELO), 3/4 (14.0K, ESFR), and K25 as required by NFPA 13, 2007 Edi- tion (see reverse). The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure setings are available and may be substituted. Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficull problem of providing the relief valve with a convenient drainage-piping outlet. Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activaticn. Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are avail- able for all TESTANDRAIN® valves. Valve and orifice size must be specified when ordering. NOTE: I: is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are requed to CLOSE at a pre sure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance Care should be taken -hat the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. TESTANDRAIN is a registered trademark of tGF Faanufacturing Inc. CS1011A 10/09 DIMENSIONS MODEL 1011 - FRONT VIEW Orifice Size Available: /8, 7A6, 1/2", 17/32", ELO (WB)*, ESFR (3/4 )*, & <5** SIZE A B C D E F G H 34" 79/16 11/2 23/16 3/8" 3/8" 113A6" 49/16 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 79Aa" 11/2 23A&' 35/8 33/8 113A6" 49A&' 63/a" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4 715A6" 111A6 29/i&' 41/4" 3/8" 115/16 5A&' 51/211 (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½" 815/16" 113/16" 31/4" 51A6' 37/s" 25/8 81/4" 107/8 (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2" 815/16 113A6" 31/4 51A6" 37/a 25/a 81/4 107/a" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) * Available on 1114 to 2' size units only ** Available on 11/2' and 2 size units only THE MODEL 1011A PROVIDES ALL OF THE FOLLOWING.. From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1" Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of no less than 1/2" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve MODEL 1011 - PLAN VIEW MATERIALS Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid APPROVALS UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM USA Patent #"474i 361 andbtPt Y W AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 A Phone: 610-240-4900 Fax: 610-240-4906 - - www.testandrain.com Job Name: Architect: Engineer: Contractor: